[GS 40.01 knx] Room climate, CO2, humidity, temperature controllers GS40.01 knx
Hugo Müller GmbH & Co KG · Order number GS40.01 knx · Sensors
Download .knxprod GS41.11 ets 2.0 · 451 KB
Product
| Manufacturer | Hugo Müller GmbH & Co KG |
|---|---|
| Product name | [GS 40.01 knx] Room climate, CO2, humidity, temperature controllers |
| Order number | GS40.01 knx |
| Product text | GS40.01 knx |
| Hardware | GS41 |
| Medium | Twisted Pair |
| Bus current (mA) | 10 |
| Rail mounted | No |
| Registration | Certified · 2022-08-30 |
| Languages | es-ES, de-DE, fr-FR, it-IT, nl-NL, sv-SE, ru-RU |
| Catalog entry | M-00FC_H-LP455.5F009-1_HP-0001-20-6216_CI-GS40.2E01.20knx-1 |
| Fingerprint | 6216 |
| SHA-256 | 6fa3d8d9f639e9db8e6fb66e363b8e1b87fbed82e6e42520b4cf778940d91987 |
| First seen | 2026-11-25 |
| Markets | 56 markets |
Application program: GS41.11 ets 2.0
| Application number | $0001 |
|---|---|
| Version | 2.0 |
| Mask version | MV-07B0 (System B) |
| KNX Data Secure | No |
| Minimum ETS version | 5.0 |
| Parameters | 1601 |
| Group objects | 516 |
Group objects (516)
| No | Name | Function | Size | DPT | Flags |
|---|---|---|---|---|---|
| 1 | Send '0' in operation | Output | 1 Bit | DPT.1 | CT |
| 1 | Send '1' in operation | Output | 1 Bit | DPT.1 | CT |
| 2 | Request status | Input | 1 Bit | DPT.1 | CW |
| 3 | operating hours counter[s] | Output (read only) | 4 Bytes | DPT.13 | CR |
| 4 | Enable/disable CO2 and RH LEDs | Input | 1 Bit | DPT.1 | CW |
| 5 | Additional Toggle Switch (Touch) | Output | 1 Bit | DPT.1 | CT |
| 16 | T: heat alarm | Output | 1 Bit | DPT.1 | CT |
| 17 | T: frost alarm | Output | 1 Bit | DPT.1 | CT |
| 18 | RTC: external temperature value 1 | Input | 2 Bytes | DPT.9 | CW |
| 19 | RTC: external temperature value 2 | Input | 2 Bytes | DPT.9 | CW |
| 20 | RTC: external temperature value 3 | Input | 2 Bytes | DPT.9 | CW |
| 21 | RTC: external temperature value 4 | Input | 2 Bytes | DPT.9 | CW |
| 22 | RTC: comfort temperature | Input | 2 Bytes | DPT.9 | CRW |
| 23 | RTC: standby setback when heating | Input | 2 Bytes | DPT.9 | CRW |
| 24 | RTC: eco setback when heating | Input | 2 Bytes | DPT.9 | CRW |
| 25 | RTC: standby increment when cooling | Input | 2 Bytes | DPT.9 | CRW |
| 26 | RTC: eco increment when cooling | Input | 2 Bytes | DPT.9 | CRW |
| 27 | RTC: frost protection temperature when heating | Input | 2 Bytes | DPT.9 | CRW |
| 28 | RTC: heat protection temperature when cooling | Input | 2 Bytes | DPT.9 | CRW |
| 29 | RTC: current set point temperature | Output | 2 Bytes | DPT.9 | CRT |
| 30 | RTC: average comfort set point temperature (symmetrical) | Output | 2 Bytes | DPT.9 | CRT |
| 31 | RTC: comfort temperature +/- 0,1K | Input | 1 Bit | DPT.1 | CW |
| 32 | RTC: comfort temperature +/- 0,5K | Input | 1 Bit | DPT.1 | CW |
| 33 | RTC: standby setback when heating +/- 0,1K | Input | 1 Bit | DPT.1 | CW |
| 34 | RTC: eco setback when heating +/- 0,1K | Input | 1 Bit | DPT.1 | CW |
| 35 | RTC: standby increment when cooling +/- 0,1K | Input | 1 Bit | DPT.1 | CW |
| 36 | RTC: eco increment when cooling +/- 0,1K | Input | 1 Bit | DPT.1 | CW |
| 37 | RTC: heating(1)/cooling(0) | Input | 1 Bit | DPT.1 | CW |
| 38 | RTC: status heating/cooling | Output | 1 Bit | DPT.1 | CRT |
| 39 | RTC: Dead zone between heating and cooling (0…10K) | Input | 2 Bytes | DPT.9 | CW |
| 40 | RTC: HVAC Mode: 1=comf, 2=stdb, 3=eco, 4=b-prot | Input | 1 Byte | DPT.20 | CW |
| 41 | RTC: HVAC Mode: 1=comf, 2=stdb, 3=eco, 4=b-prot | Output | 1 Byte | DPT.20 | CRT |
| 42 | RTC: comfort mode enable | Input | 1 Bit | DPT.1 | CW |
| 43 | RTC: standby mode enable | Input | 1 Bit | DPT.1 | CW |
| 44 | RTC: eco mode enable | Input | 1 Bit | DPT.1 | CW |
| 45 | RTC: Frost-/heat protection enable | Input | 1 Bit | DPT.1 | CW |
| 46 | RTC: setpoint override value | Input | 2 Bytes | DPT.9 | CW |
| 47 | RTC: status heating | Output | 1 Bit | DPT.1 | CT |
| 48 | RTC: status cooling | Output | 1 Bit | DPT.1 | CT |
| 49 | RTC: RHCC status | Output | 2 Bytes | DPT.22 | CRT |
| 50 | RTC: control value main level heating | Output | 1 Byte | DPT.5 | CT |
| 50 | RTC: control value main level heating | Output | 1 Bit | DPT.1 | CT |
| 51 | RTC: control value extra level heating | Output | 1 Byte | DPT.5 | CT |
| 51 | RTC: control value extra level heating | Output | 1 Bit | DPT.1 | CT |
| 52 | RTC: control value main level cooling | Output | 1 Byte | DPT.5 | CT |
| 52 | RTC: control value main level cooling | Output | 1 Bit | DPT.1 | CT |
| 53 | RTC: control value extra level cooling | Output | 1 Byte | DPT.5 | CT |
| 53 | RTC: control value extra level cooling | Output | 1 Bit | DPT.1 | CT |
| 54 | RTC: guide value [°C] | Input | 2 Bytes | DPT.9 | CW |
| 55 | RTC: blocking object heating | Input | 1 Bit | DPT.1 | CW |
| 56 | RTC: blocking object cooling | Input | 1 Bit | DPT.1 | CW |
| 57 | RTC: blocking object extra level heating | Input | 1 Bit | DPT.1 | CW |
| 58 | RTC: blocking object extra level cooling | Input | 1 Bit | DPT.1 | CW |
| 59 | RTC: Reset manual offset | Input | 1 Bit | DPT.1 | CW |
| 60 | RTC: Block manual offset | Input | 1 Bit | DPT.1 | CW |
| 61 | RTC: Manual offset value | Output | 2 Bytes | DPT.9 | CT |
| 62 | Party start/stop/retrigger | Input | 1 Bit | DPT.1 | CW |
| 66 | HUMCMP: Absolute humidity value 1 [g/m3] | Input | 2 Bytes | DPT.9 | CW |
| 66 | HUMCMP: Relative humidity value 1 [%] | Input | 1 Byte | DPT.5 | CW |
| 67 | HUMCMP: Temperature value 1 [°C] | Input | 2 Bytes | DPT.9 | CW |
| 68 | HUMCMP: Absolute humidity value 2 [g/m3] | Input | 2 Bytes | DPT.9 | CW |
| 68 | HUMCMP: Relative humidity value 2 [%] | Input | 1 Byte | DPT.5 | CW |
| 69 | HUMCMP: Temperature value 2 [°C] | Input | 2 Bytes | DPT.9 | CW |
| 70 | HUMCMP: Humidity comparator output | Output | 1 Bit | DPT.1 | CT |
| 71 | DEWP: dew point temperature [°C] | Output | 2 Bytes | DPT.9 | CT |
| 72 | DEWP: dew point alarm enabled (switching object) | Output | 1 Bit | DPT.1 | CT |
| 72 | DEWP: dew point alarm enabled (priority) | Output | 2 Bit | DPT.2 | CT |
| 72 | DEWP: dew point alarm enabled (0...100%) | Output | 1 Byte | DPT.5 | CT |
| 72 | DEWP: dew point alarm enabled (0...255) | Output | 1 Byte | DPT.5 | CT |
| 72 | DEWP: dew point alarm enabled scene (1...64) | Output | 1 Byte | DPT.17 | CT |
| 73 | DEWP: request dew point temperature | Input | 1 Bit | DPT.1 | CW |
| 74 | P: absolute air pressure [Pa] | Output | 2 Bytes | DPT.9 | CT |
| 75 | P: relative air pressure [Pa] | Output | 2 Bytes | DPT.9 | CT |
| 76 | P: air pressure sensor error | Output | 1 Bit | DPT.1 | CT |
| 77 | P: request absolute air pressure | Input | 1 Bit | DPT.1 | CW |
| 78 | P: request relative air pressure | Input | 1 Bit | DPT.1 | CW |
| 79 | VAVC: control value (0...255) | Output | 1 Byte | DPT.5 | CT |
| 79 | VAVC: control value (0...100%) | Output | 1 Byte | DPT.5 | CT |
| 80 | VAVC: external object (0…100%) | Input | 1 Byte | DPT.5 | CW |
| 81 | VAVC: Input set selection. | Input | 1 Bit | DPT.1 | CW |
| 82 | VAVC: blocking object | Input | 1 Bit | DPT.1 | CW |
| 86 | CO2C: external CO2 value 1 [ppm] | Input | 2 Bytes | DPT.9 | CW |
| 87 | CO2C: external CO2 value 2 [ppm] | Input | 2 Bytes | DPT.9 | CW |
| 88 | CO2C: external CO2 value 3 [ppm] | Input | 2 Bytes | DPT.9 | CW |
| 89 | CO2C: external CO2 value 4 [ppm] | Input | 2 Bytes | DPT.9 | CW |
| 90 | CO2C: control value (0...255) | Output | 1 Byte | DPT.5 | CT |
| 90 | CO2C: control value (0...100%) | Output | 1 Byte | DPT.5 | CT |
| 90 | CO2C: scene (1...64) | Output | 1 Byte | DPT.17 | CT |
| 90 | CO2C: control value level 1 (switching object) | Output | 1 Bit | DPT.1 | CT |
| 90 | CO2C: control value level 1 (priority) | Output | 2 Bit | DPT.2 | CT |
| 91 | CO2C: control value level 2 (switching object) | Output | 1 Bit | DPT.1 | CT |
| 91 | CO2C: control value level 2 (priority) | Output | 2 Bit | DPT.2 | CT |
| 92 | CO2C: control value level 3 (switching object) | Output | 1 Bit | DPT.1 | CT |
| 92 | CO2C: control value level 3 (priority) | Output | 2 Bit | DPT.2 | CT |
| 93 | CO2C: base set point [ppm] | Input | 2 Bytes | DPT.9 | CW |
| 94 | GO_CTL_0_SETPOINT_VAL_PROC | GO_CTL_0_SETPOINT_VAL_PROC | 1 Byte | DPT.5 | CW |
| 95 | CO2C: blocking object level 1 | Input | 1 Bit | DPT.1 | CW |
| 96 | CO2C: blocking object level 2 | Input | 1 Bit | DPT.1 | CW |
| 97 | CO2C: blocking object level 3 | Input | 1 Bit | DPT.1 | CW |
| 98 | CO2C: blocking object | Input | 1 Bit | DPT.1 | CW |
| 99 | RHC: humidity external value 1 [%] | Input | 1 Byte | DPT.5 | CW |
| 100 | RHC: external humidity value 2 [%] | Input | 1 Byte | DPT.5 | CW |
| 101 | RHC: external humidity value 3 [%] | Input | 1 Byte | DPT.5 | CW |
| 102 | RHC: external humidity value 4 [%] | Input | 1 Byte | DPT.5 | CW |
| 103 | RHC: control value (0...255) | Output | 1 Byte | DPT.5 | CT |
| 103 | RHC: control value (0...100%) | Output | 1 Byte | DPT.5 | CT |
| 103 | RHC: scene (1...64) | Output | 1 Byte | DPT.17 | CT |
| 103 | RHC: control value level 1 (switching object) | Output | 1 Bit | DPT.1 | CT |
| 103 | RHC: control value level 1 (priority) | Output | 2 Bit | DPT.2 | CT |
| 104 | RHC: control value level 2 (switching object) | Output | 1 Bit | DPT.1 | CT |
| 104 | RHC: control value level 2 (priority) | Output | 2 Bit | DPT.2 | CT |
| 105 | RHC: control value level 3 (switching object) | Output | 1 Bit | DPT.1 | CT |
| 105 | RHC: control value level 3 (priority) | Output | 2 Bit | DPT.2 | CT |
| 106 | RHC: base set point [%] | Input | 2 Bytes | DPT.9 | CW |
| 107 | RHC: base set point (1 byte) [%] | Input | 1 Byte | DPT.5 | CW |
| 108 | RHC: blocking object level 1 | Input | 1 Bit | DPT.1 | CW |
| 109 | RHC: blocking object level 2 | Input | 1 Bit | DPT.1 | CW |
| 110 | RHC: blocking object level 3 | Input | 1 Bit | DPT.1 | CW |
| 111 | RHC: blocking object | Input | 1 Bit | DPT.1 | CW |
| 112 | CO2: CO2 value [ppm] | Output | 2 Bytes | DPT.9 | CT |
| 113 | GO_SENSOR_0_INTERN_PROC | GO_SENSOR_0_INTERN_PROC | 1 Byte | DPT.5 | CT |
| 114 | CO2: request CO2 value | Input | 1 Bit | DPT.1 | CW |
| 115 | CO2: sensor error | Output | 1 Bit | DPT.1 | CT |
| 116 | CO2: start/stop calibration | Input | 1 Bit | DPT.1 | CW |
| 117 | CO2: adopt CO2 calibration value | Input | 2 Bytes | DPT.9 | CW |
| 118 | CO2: CO2 value external [ppm] | Input | 2 Bytes | DPT.9 | CT |
| 119 | CO2: min value | Output | 2 Bytes | DPT.9 | CT |
| 120 | CO2: max value | Output | 2 Bytes | DPT.9 | CT |
| 121 | CO2: request min/max values | Input | 1 Bit | DPT.1 | CW |
| 122 | CO2: reset min/max values | Input | 1 Bit | DPT.1 | CW |
| 123 | rH: humidity value [%] | Output | 2 Bytes | DPT.9 | CT |
| 124 | rH: humidity value (1 byte) [%] | Output | 1 Byte | DPT.5 | CT |
| 125 | rH: request humidity value | Input | 1 Bit | DPT.1 | CW |
| 126 | rH: sensor error | Output | 1 Bit | DPT.1 | CT |
| 127 | GO_SENSOR_1_CALI_VENTILATION_START_STOP | GO_SENSOR_1_CALI_VENTILATION_START_STOP | 1 Bit | DPT.1 | CW |
| 128 | GO_SENSOR_1_CALI_CURRENT_VAL | GO_SENSOR_1_CALI_CURRENT_VAL | 2 Bytes | DPT.9 | CW |
| 129 | rH: humidity value external [%] | Input | 2 Bytes | DPT.9 | CT |
| 130 | rH: min value | Output | 2 Bytes | DPT.9 | CT |
| 131 | rH: max value | Output | 2 Bytes | DPT.9 | CT |
| 132 | rH: request min/max values | Input | 1 Bit | DPT.1 | CW |
| 133 | rH: reset min/max values | Input | 1 Bit | DPT.1 | CW |
| 134 | T: temperature value [°C] | Output | 2 Bytes | DPT.9 | CT |
| 135 | GO_SENSOR_2_INTERN_PROC | GO_SENSOR_2_INTERN_PROC | 1 Byte | DPT.5 | CT |
| 136 | T: request temperature value | Input | 1 Bit | DPT.1 | CW |
| 137 | T: sensor error | Output | 1 Bit | DPT.1 | CT |
| 138 | GO_SENSOR_2_CALI_VENTILATION_START_STOP | GO_SENSOR_2_CALI_VENTILATION_START_STOP | 1 Bit | DPT.1 | CW |
| 139 | GO_SENSOR_2_CALI_CURRENT_VAL | GO_SENSOR_2_CALI_CURRENT_VAL | 2 Bytes | DPT.9 | CW |
| 140 | T: Temperature value external [°C] | Input | 2 Bytes | DPT.9 | CT |
| 141 | T: temperature min value | Output | 2 Bytes | DPT.9 | CT |
| 142 | T: temperature max value | Output | 2 Bytes | DPT.9 | CT |
| 143 | T: request min/max temperature values | Input | 1 Bit | DPT.1 | CW |
| 144 | T: reset min/max temperature values | Input | 1 Bit | DPT.1 | CW |
| 152 | E1 Switching sensor | Output | 1 Bit | DPT.1 | CWT |
| 152 | E1 Alarm sensor | Output | 1 Bit | DPT.1 | CWT |
| 152 | E1 Switching | Output | 1 Bit | DPT.1 | CWT |
| 152 | E1 Blind UP/DOWN | Output | 1 Bit | DPT.1 | CWT |
| 152 | E1 Switch (event 0) | Output | 1 Bit | DPT.1 | CT |
| 152 | E1 Priority (event 0) | Output | 2 Bit | DPT.2 | CT |
| 152 | E1 1-byte value (-128 to 127) (event 0) | Output | 1 Byte | DPT.6 | CT |
| 152 | E1 1-byte value (0 to 255) (event 0) | Output | 1 Byte | DPT.5 | CT |
| 152 | E1 Scene (event 0) | Output | 1 Byte | DPT.18 | CT |
| 152 | E1 2-byte value (-32,768 to 32,767) (event 0) | Output | 2 Bytes | DPT.8 | CT |
| 152 | E1 2-byte value (0 to 65,535) (event 0) | Output | 2 Bytes | DPT.7 | CT |
| 152 | E1 4-byte value (-2,147,483,648 to 2,147,483,647) (event 0) | Output | 4 Bytes | DPT.13 | CT |
| 152 | E1 4-byte value (0 to 4294967295) (event 0) | Output | 4 Bytes | DPT.12 | CT |
| 152 | E1 2-byte floating point (event 0) | Output | 2 Bytes | DPT.9 | CT |
| 152 | E1 Scene | Output | 1 Byte | DPT.18 | CWTU |
| 152 | E1 Switching step 1 | Output | 1 Bit | DPT.1 | CWT |
| 152 | E1 Switching 1 actuation | Output | 1 Bit | DPT.1 | CWT |
| 152 | E1 HZ: Counter reading 1-byte value | Output | 1 Byte | DPT.6 | CT |
| 152 | E1 HZ: Counter reading 1-byte value | Output | 1 Byte | DPT.5 | CT |
| 152 | E1 HZ: Counter reading 2-byte value | Output | 2 Bytes | DPT.8 | CT |
| 152 | E1 HZ: Counter reading 2-byte value | Output | 2 Bytes | DPT.7 | CT |
| 152 | E1 HZ: Counter reading 4-byte value | Output | 4 Bytes | DPT.13 | CT |
| 152 | E1 1-byte value (-128 to 127) | Output | 1 Byte | DPT.6 | CT |
| 152 | E1 1-byte value (0 to 255) | Output | 1 Byte | DPT.5 | CT |
| 152 | E1 2-byte value (-32,768 to 32,767) | Output | 2 Bytes | DPT.8 | CT |
| 152 | E1 2-byte value (0 to 65,535) | Output | 2 Bytes | DPT.7 | CT |
| 152 | E1 2-byte floating point | Output | 2 Bytes | DPT.9 | CT |
| 152 | E1 4-byte floating point | Output | 4 Bytes | DPT.14 | CT |
| 153 | E1 Dimming | Output | 4 Bit | DPT.3 | CT |
| 153 | E1 STOP/slat adjustment | Output | 1 Bit | DPT.1 | CT |
| 153 | E1 Switch (event 1) | Output | 1 Bit | DPT.1 | CT |
| 153 | E1 Priority (event 1) | Output | 2 Bit | DPT.2 | CT |
| 153 | E1 1-byte value (-128 to 127) (event 1) | Output | 1 Byte | DPT.6 | CT |
| 153 | E1 1-byte value (0 to 255) (event 1) | Output | 1 Byte | DPT.5 | CT |
| 153 | E1 Scene (event 1) | Output | 1 Byte | DPT.18 | CT |
| 153 | E1 2-byte value (-32,768 to 32,767) (event 1) | Output | 2 Bytes | DPT.8 | CT |
| 153 | E1 2-byte value (0 to 65,535) (event 1) | Output | 2 Bytes | DPT.7 | CT |
| 153 | E1 4-byte value (-2,147,483,648 to 2,147,483,647) (event 1) | Output | 4 Bytes | DPT.13 | CT |
| 153 | E1 4-byte value (0 to 4294967295) (event 1) | Output | 4 Bytes | DPT.12 | CT |
| 153 | E1 2-byte floating point (event 1) | Output | 2 Bytes | DPT.9 | CT |
| 153 | E1 Switching step 2 | Output | 1 Bit | DPT.1 | CWT |
| 153 | E1 Switching 2 actuations | Output | 1 Bit | DPT.1 | CWT |
| 153 | E1 ZZ: Counter reading 1-byte value | Output | 1 Byte | DPT.6 | CT |
| 153 | E1 ZZ: Counter reading 1-byte value | Output | 1 Byte | DPT.5 | CT |
| 153 | E1 ZZ: Counter reading 2-byte value | Output | 2 Bytes | DPT.8 | CT |
| 153 | E1 ZZ: Counter reading 2-byte value | Output | 2 Bytes | DPT.7 | CT |
| 153 | E1 ZZ: Counter reading 4-byte value | Output | 4 Bytes | DPT.13 | CT |
| 153 | Request E1 | Input | 1 Bit | DPT.1 | CW |
| 154 | E1 Start event 0/1 | Input | 1 Bit | DPT.1 | CW |
| 154 | E1 Top end position | Input | 1 Bit | DPT.1 | CW |
| 154 | E1 Scene storage display | Output | 1 Bit | DPT.1 | CT |
| 154 | E1 Switching step 3 | Output | 1 Bit | DPT.1 | CWT |
| 154 | E1 Switching 3 actuations | Output | 1 Bit | DPT.1 | CWT |
| 154 | E1 HZ: Request counter reading | Input | 1 Bit | DPT.1 | CW |
| 154 | E1 Outside of range | Output | 1 Bit | DPT.1 | CT |
| 155 | E1 Bottom end position | Input | 1 Bit | DPT.1 | CW |
| 155 | E1 Switching step 4 | Output | 1 Bit | DPT.1 | CWT |
| 155 | E1 Switching 4 actuations | Output | 1 Bit | DPT.1 | CWT |
| 155 | E1 HZ: Limit value exceeded | Output | 1 Bit | DPT.1 | CT |
| 155 | E1 Threshold value | Output | 1 Bit | DPT.1 | CT |
| 155 | E1 Threshold value | Output | 1 Byte | DPT.5 | CT |
| 155 | E1 Threshold value | Output | 2 Bytes | DPT.7 | CT |
| 155 | E1 Threshold value | Output | 2 Bytes | DPT.9 | CT |
| 156 | E1 Save scene | Input | 1 Bit | DPT.1 | CW |
| 156 | E1 Enable save | Input | 1 Bit | DPT.1 | CW |
| 156 | E1 Switching step 5 | Output | 1 Bit | DPT.1 | CWT |
| 156 | E1 Switching, long actuation | Output | 1 Bit | DPT.1 | CWT |
| 157 | E1 Switch step UP/DOWN | Input | 1 Bit | DPT.1 | CW |
| 157 | E1 ZZ: Limit value exceeded | Output | 1 Bit | DPT.1 | CT |
| 157 | E1 Change threshold, tolerance band lower limit | Input | 1 Byte | DPT.5 | CW |
| 158 | E1 Actuating number | Input | 1 Byte | DPT.5 | CWTU |
| 158 | E1 ZZ: Request counter reading | Input | 1 Bit | DPT.1 | CW |
| 158 | E1 Change threshold, tolerance band upper limit | Input | 1 Byte | DPT.5 | CW |
| 159 | E1 ZZ: Reverse direction | Input | 1 Bit | DPT.1 | CW |
| 159 | E1 Send if threshold value undershot | Input | 1 Byte | DPT.5 | CW |
| 159 | E1 Send if threshold value undershot | Input | 2 Bytes | DPT.7 | CW |
| 159 | E1 Send if threshold value undershot | Input | 2 Bytes | DPT.9 | CW |
| 160 | E1 ZZ: Reset | Input | 1 Bit | DPT.1 | CW |
| 160 | E1 Send if threshold value exceeded | Input | 1 Byte | DPT.5 | CW |
| 160 | E1 Send if threshold value exceeded | Input | 2 Bytes | DPT.7 | CW |
| 160 | E1 Send if threshold value exceeded | Input | 2 Bytes | DPT.9 | CW |
| 161 | E1 ZZ: Stop | Input | 1 Bit | DPT.1 | CW |
| 170 | E1 Disable | Input | 1 Bit | DPT.1 | CW |
| 172 | E2 Switching sensor | Output | 1 Bit | DPT.1 | CWT |
| 172 | E2 Alarm sensor | Output | 1 Bit | DPT.1 | CWT |
| 172 | E2 Switching | Output | 1 Bit | DPT.1 | CWT |
| 172 | E2 Blind UP/DOWN | Output | 1 Bit | DPT.1 | CWT |
| 172 | E2 Switch (event 0) | Output | 1 Bit | DPT.1 | CT |
| 172 | E2 Priority (event 0) | Output | 2 Bit | DPT.2 | CT |
| 172 | E2 1-byte value (-128 to 127) (event 0) | Output | 1 Byte | DPT.6 | CT |
| 172 | E2 1-byte value (0 to 255) (event 0) | Output | 1 Byte | DPT.5 | CT |
| 172 | E2 Scene (event 0) | Output | 1 Byte | DPT.18 | CT |
| 172 | E2 2-byte value (-32,768 to 32,767) (event 0) | Output | 2 Bytes | DPT.8 | CT |
| 172 | E2 2-byte value (0 to 65,535) (event 0) | Output | 2 Bytes | DPT.7 | CT |
| 172 | E2 4-byte value (-2,147,483,648 to 2,147,483,647) (event 0) | Output | 4 Bytes | DPT.13 | CT |
| 172 | E2 4-byte value (0 to 4294967295) (event 0) | Output | 4 Bytes | DPT.12 | CT |
| 172 | E2 2-byte floating point (event 0) | Output | 2 Bytes | DPT.9 | CT |
| 172 | E2 Scene | Output | 1 Byte | DPT.18 | CWTU |
| 172 | E2 Switching step 1 | Output | 1 Bit | DPT.1 | CWT |
| 172 | E2 Switching 1 actuation | Output | 1 Bit | DPT.1 | CWT |
| 172 | E2 HZ: Counter reading 1-byte value | Output | 1 Byte | DPT.6 | CT |
| 172 | E2 HZ: Counter reading 1-byte value | Output | 1 Byte | DPT.5 | CT |
| 172 | E2 HZ: Counter reading 2-byte value | Output | 2 Bytes | DPT.8 | CT |
| 172 | E2 HZ: Counter reading 2-byte value | Output | 2 Bytes | DPT.7 | CT |
| 172 | E2 HZ: Counter reading 4-byte value | Output | 4 Bytes | DPT.13 | CT |
| 173 | E2 Dimming | Output | 4 Bit | DPT.3 | CT |
| 173 | E2 STOP/slat adjustment | Output | 1 Bit | DPT.1 | CT |
| 173 | E2 Switch (event 1) | Output | 1 Bit | DPT.1 | CT |
| 173 | E2 Priority (event 1) | Output | 2 Bit | DPT.2 | CT |
| 173 | E2 1-byte value (-128 to 127) (event 1) | Output | 1 Byte | DPT.6 | CT |
| 173 | E2 1-byte value (0 to 255) (event 1) | Output | 1 Byte | DPT.5 | CT |
| 173 | E2 Scene (event 1) | Output | 1 Byte | DPT.18 | CT |
| 173 | E2 2-byte value (-32,768 to 32,767) (event 1) | Output | 2 Bytes | DPT.8 | CT |
| 173 | E2 2-byte value (0 to 65,535) (event 1) | Output | 2 Bytes | DPT.7 | CT |
| 173 | E2 4-byte value (-2,147,483,648 to 2,147,483,647) (event 1) | Output | 4 Bytes | DPT.13 | CT |
| 173 | E2 4-byte value (0 to 4294967295) (event 1) | Output | 4 Bytes | DPT.12 | CT |
| 173 | E2 2-byte floating point (event 1) | Output | 2 Bytes | DPT.9 | CT |
| 173 | E2 Switching step 2 | Output | 1 Bit | DPT.1 | CWT |
| 173 | E2 Switching 2 actuations | Output | 1 Bit | DPT.1 | CWT |
| 173 | E2 ZZ: Counter reading 1-byte value | Output | 1 Byte | DPT.6 | CT |
| 173 | E2 ZZ: Counter reading 1-byte value | Output | 1 Byte | DPT.5 | CT |
| 173 | E2 ZZ: Counter reading 2-byte value | Output | 2 Bytes | DPT.8 | CT |
| 173 | E2 ZZ: Counter reading 2-byte value | Output | 2 Bytes | DPT.7 | CT |
| 173 | E2 ZZ: Counter reading 4-byte value | Output | 4 Bytes | DPT.13 | CT |
| 174 | E2 Start event 0/1 | Input | 1 Bit | DPT.1 | CW |
| 174 | E2 Top end position | Input | 1 Bit | DPT.1 | CW |
| 174 | E2 Scene storage display | Output | 1 Bit | DPT.1 | CT |
| 174 | E2 Switching step 3 | Output | 1 Bit | DPT.1 | CWT |
| 174 | E2 Switching 3 actuations | Output | 1 Bit | DPT.1 | CWT |
| 174 | E2 HZ: Request counter reading | Input | 1 Bit | DPT.1 | CW |
| 175 | E2 Bottom end position | Input | 1 Bit | DPT.1 | CW |
| 175 | E2 Switching step 4 | Output | 1 Bit | DPT.1 | CWT |
| 175 | E2 Switching 4 actuations | Output | 1 Bit | DPT.1 | CWT |
| 175 | E2 HZ: Limit value exceeded | Output | 1 Bit | DPT.1 | CT |
| 176 | E2 Save scene | Input | 1 Bit | DPT.1 | CW |
| 176 | E2 Enable save | Input | 1 Bit | DPT.1 | CW |
| 176 | E2 Switching step 5 | Output | 1 Bit | DPT.1 | CWT |
| 176 | E2 Switching, long actuation | Output | 1 Bit | DPT.1 | CWT |
| 177 | E2 Switch step UP/DOWN | Input | 1 Bit | DPT.1 | CW |
| 177 | E2 ZZ: Limit value exceeded | Output | 1 Bit | DPT.1 | CT |
| 178 | E2 Actuating number | Input | 1 Byte | DPT.5 | CWTU |
| 178 | E2 ZZ: Request counter reading | Input | 1 Bit | DPT.1 | CW |
| 179 | E2 ZZ: Reverse direction | Input | 1 Bit | DPT.1 | CW |
| 180 | E2 ZZ: Reset | Input | 1 Bit | DPT.1 | CW |
| 181 | E2 ZZ: Stop | Input | 1 Bit | DPT.1 | CW |
| 190 | E2 Disable | Input | 1 Bit | DPT.1 | CW |
| 192 | E3 Switching sensor | Output | 1 Bit | DPT.1 | CWT |
| 192 | E3 Alarm sensor | Output | 1 Bit | DPT.1 | CWT |
| 192 | E3 Switching | Output | 1 Bit | DPT.1 | CWT |
| 192 | E3 Blind UP/DOWN | Output | 1 Bit | DPT.1 | CWT |
| 192 | E3 Switch (event 0) | Output | 1 Bit | DPT.1 | CT |
| 192 | E3 Priority (event 0) | Output | 2 Bit | DPT.2 | CT |
| 192 | E3 1-byte value (-128 to 127) (event 0) | Output | 1 Byte | DPT.6 | CT |
| 192 | E3 1-byte value (0 to 255) (event 0) | Output | 1 Byte | DPT.5 | CT |
| 192 | E3 Scene (event 0) | Output | 1 Byte | DPT.18 | CT |
| 192 | E3 2-byte value (-32,768 to 32,767) (event 0) | Output | 2 Bytes | DPT.8 | CT |
| 192 | E3 2-byte value (0 to 65,535) (event 0) | Output | 2 Bytes | DPT.7 | CT |
| 192 | E3 4-byte value (-2,147,483,648 to 2,147,483,647) (event 0) | Output | 4 Bytes | DPT.13 | CT |
| 192 | E3 4-byte value (0 to 4294967295) (event 0) | Output | 4 Bytes | DPT.12 | CT |
| 192 | E3 2-byte floating point (event 0) | Output | 2 Bytes | DPT.9 | CT |
| 192 | E3 Scene | Output | 1 Byte | DPT.18 | CWTU |
| 192 | E3 Switching step 1 | Output | 1 Bit | DPT.1 | CWT |
| 192 | E3 Switching 1 actuation | Output | 1 Bit | DPT.1 | CWT |
| 192 | E3 HZ: Counter reading 1-byte value | Output | 1 Byte | DPT.6 | CT |
| 192 | E3 HZ: Counter reading 1-byte value | Output | 1 Byte | DPT.5 | CT |
| 192 | E3 HZ: Counter reading 2-byte value | Output | 2 Bytes | DPT.8 | CT |
| 192 | E3 HZ: Counter reading 2-byte value | Output | 2 Bytes | DPT.7 | CT |
| 192 | E3 HZ: Counter reading 4-byte value | Output | 4 Bytes | DPT.13 | CT |
| 193 | E3 Dimming | Output | 4 Bit | DPT.3 | CT |
| 193 | E3 STOP/slat adjustment | Output | 1 Bit | DPT.1 | CT |
| 193 | E3 Switch (event 1) | Output | 1 Bit | DPT.1 | CT |
| 193 | E3 Priority (event 1) | Output | 2 Bit | DPT.2 | CT |
| 193 | E3 1-byte value (-128 to 127) (event 1) | Output | 1 Byte | DPT.6 | CT |
| 193 | E3 1-byte value (0 to 255) (event 1) | Output | 1 Byte | DPT.5 | CT |
| 193 | E3 Scene (event 1) | Output | 1 Byte | DPT.18 | CT |
| 193 | E3 2-byte value (-32,768 to 32,767) (event 1) | Output | 2 Bytes | DPT.8 | CT |
| 193 | E3 2-byte value (0 to 65,535) (event 1) | Output | 2 Bytes | DPT.7 | CT |
| 193 | E3 4-byte value (-2,147,483,648 to 2,147,483,647) (event 1) | Output | 4 Bytes | DPT.13 | CT |
| 193 | E3 4-byte value (0 to 4294967295) (event 1) | Output | 4 Bytes | DPT.12 | CT |
| 193 | E3 2-byte floating point (event 1) | Output | 2 Bytes | DPT.9 | CT |
| 193 | E3 Switching step 2 | Output | 1 Bit | DPT.1 | CWT |
| 193 | E3 Switching 2 actuations | Output | 1 Bit | DPT.1 | CWT |
| 193 | E3 ZZ: Counter reading 1-byte value | Output | 1 Byte | DPT.6 | CT |
| 193 | E3 ZZ: Counter reading 1-byte value | Output | 1 Byte | DPT.5 | CT |
| 193 | E3 ZZ: Counter reading 2-byte value | Output | 2 Bytes | DPT.8 | CT |
| 193 | E3 ZZ: Counter reading 2-byte value | Output | 2 Bytes | DPT.7 | CT |
| 193 | E3 ZZ: Counter reading 4-byte value | Output | 4 Bytes | DPT.13 | CT |
| 194 | E3 Start event 0/1 | Input | 1 Bit | DPT.1 | CW |
| 194 | E3 Top end position | Input | 1 Bit | DPT.1 | CW |
| 194 | E3 Scene storage display | Output | 1 Bit | DPT.1 | CT |
| 194 | E3 Switching step 3 | Output | 1 Bit | DPT.1 | CWT |
| 194 | E3 Switching 3 actuations | Output | 1 Bit | DPT.1 | CWT |
| 194 | E3 HZ: Request counter reading | Input | 1 Bit | DPT.1 | CW |
| 195 | E3 Bottom end position | Input | 1 Bit | DPT.1 | CW |
| 195 | E3 Switching step 4 | Output | 1 Bit | DPT.1 | CWT |
| 195 | E3 Switching 4 actuations | Output | 1 Bit | DPT.1 | CWT |
| 195 | E3 HZ: Limit value exceeded | Output | 1 Bit | DPT.1 | CT |
| 196 | E3 Save scene | Input | 1 Bit | DPT.1 | CW |
| 196 | E3 Enable save | Input | 1 Bit | DPT.1 | CW |
| 196 | E3 Switching step 5 | Output | 1 Bit | DPT.1 | CWT |
| 196 | E3 Switching, long actuation | Output | 1 Bit | DPT.1 | CWT |
| 197 | E3 Switch step UP/DOWN | Input | 1 Bit | DPT.1 | CW |
| 197 | E3 ZZ: Limit value exceeded | Output | 1 Bit | DPT.1 | CT |
| 198 | E3 Actuating number | Input | 1 Byte | DPT.5 | CWTU |
| 198 | E3 ZZ: Request counter reading | Input | 1 Bit | DPT.1 | CW |
| 199 | E3 ZZ: Reverse direction | Input | 1 Bit | DPT.1 | CW |
| 200 | E3 ZZ: Reset | Input | 1 Bit | DPT.1 | CW |
| 201 | E3 ZZ: Stop | Input | 1 Bit | DPT.1 | CW |
| 210 | E3 Disable | Input | 1 Bit | DPT.1 | CW |
| 212 | E4 Switching sensor | Output | 1 Bit | DPT.1 | CWT |
| 212 | E4 Alarm sensor | Output | 1 Bit | DPT.1 | CWT |
| 212 | E4 Switching | Output | 1 Bit | DPT.1 | CWT |
| 212 | E4 Blind UP/DOWN | Output | 1 Bit | DPT.1 | CWT |
| 212 | E4 Switch (event 0) | Output | 1 Bit | DPT.1 | CT |
| 212 | E4 Priority (event 0) | Output | 2 Bit | DPT.2 | CT |
| 212 | E4 1-byte value (-128 to 127) (event 0) | Output | 1 Byte | DPT.6 | CT |
| 212 | E4 1-byte value (0 to 255) (event 0) | Output | 1 Byte | DPT.5 | CT |
| 212 | E4 Scene (event 0) | Output | 1 Byte | DPT.18 | CT |
| 212 | E4 2-byte value (-32,768 to 32,767) (event 0) | Output | 2 Bytes | DPT.8 | CT |
| 212 | E4 2-byte value (0 to 65,535) (event 0) | Output | 2 Bytes | DPT.7 | CT |
| 212 | E4 4-byte value (-2,147,483,648 to 2,147,483,647) (event 0) | Output | 4 Bytes | DPT.13 | CT |
| 212 | E4 4-byte value (0 to 4294967295) (event 0) | Output | 4 Bytes | DPT.12 | CT |
| 212 | E4 2-byte floating point (event 0) | Output | 2 Bytes | DPT.9 | CT |
| 212 | E4 Scene | Output | 1 Byte | DPT.18 | CWTU |
| 212 | E4 Switching step 1 | Output | 1 Bit | DPT.1 | CWT |
| 212 | E4 Switching 1 actuation | Output | 1 Bit | DPT.1 | CWT |
| 212 | E4 HZ: Counter reading 1-byte value | Output | 1 Byte | DPT.6 | CT |
| 212 | E4 HZ: Counter reading 1-byte value | Output | 1 Byte | DPT.5 | CT |
| 212 | E4 HZ: Counter reading 2-byte value | Output | 2 Bytes | DPT.8 | CT |
| 212 | E4 HZ: Counter reading 2-byte value | Output | 2 Bytes | DPT.7 | CT |
| 212 | E4 HZ: Counter reading 4-byte value | Output | 4 Bytes | DPT.13 | CT |
| 212 | E4 Output value | Output | 2 Bytes | DPT.9 | CT |
| 213 | E4 Dimming | Output | 4 Bit | DPT.3 | CT |
| 213 | E4 STOP/slat adjustment | Output | 1 Bit | DPT.1 | CT |
| 213 | E4 Switch (event 1) | Output | 1 Bit | DPT.1 | CT |
| 213 | E4 Priority (event 1) | Output | 2 Bit | DPT.2 | CT |
| 213 | E4 1-byte value (-128 to 127) (event 1) | Output | 1 Byte | DPT.6 | CT |
| 213 | E4 1-byte value (0 to 255) (event 1) | Output | 1 Byte | DPT.5 | CT |
| 213 | E4 Scene (event 1) | Output | 1 Byte | DPT.18 | CT |
| 213 | E4 2-byte value (-32,768 to 32,767) (event 1) | Output | 2 Bytes | DPT.8 | CT |
| 213 | E4 2-byte value (0 to 65,535) (event 1) | Output | 2 Bytes | DPT.7 | CT |
| 213 | E4 4-byte value (-2,147,483,648 to 2,147,483,647) (event 1) | Output | 4 Bytes | DPT.13 | CT |
| 213 | E4 4-byte value (0 to 4294967295) (event 1) | Output | 4 Bytes | DPT.12 | CT |
| 213 | E4 2-byte floating point (event 1) | Output | 2 Bytes | DPT.9 | CT |
| 213 | E4 Switching step 2 | Output | 1 Bit | DPT.1 | CWT |
| 213 | E4 Switching 2 actuations | Output | 1 Bit | DPT.1 | CWT |
| 213 | E4 ZZ: Counter reading 1-byte value | Output | 1 Byte | DPT.6 | CT |
| 213 | E4 ZZ: Counter reading 1-byte value | Output | 1 Byte | DPT.5 | CT |
| 213 | E4 ZZ: Counter reading 2-byte value | Output | 2 Bytes | DPT.8 | CT |
| 213 | E4 ZZ: Counter reading 2-byte value | Output | 2 Bytes | DPT.7 | CT |
| 213 | E4 ZZ: Counter reading 4-byte value | Output | 4 Bytes | DPT.13 | CT |
| 213 | E4 Request output value | Input | 1 Bit | DPT.1 | CW |
| 214 | E4 Start event 0/1 | Input | 1 Bit | DPT.1 | CW |
| 214 | E4 Top end position | Input | 1 Bit | DPT.1 | CW |
| 214 | E4 Scene storage display | Output | 1 Bit | DPT.1 | CT |
| 214 | E4 Switching step 3 | Output | 1 Bit | DPT.1 | CWT |
| 214 | E4 Switching 3 actuations | Output | 1 Bit | DPT.1 | CWT |
| 214 | E4 HZ: Request counter reading | Input | 1 Bit | DPT.1 | CW |
| 214 | E4 Measured value outside of range | Output | 1 Bit | DPT.1 | CT |
| 215 | E4 Bottom end position | Input | 1 Bit | DPT.1 | CW |
| 215 | E4 Switching step 4 | Output | 1 Bit | DPT.1 | CWT |
| 215 | E4 Switching 4 actuations | Output | 1 Bit | DPT.1 | CWT |
| 215 | E4 HZ: Limit value exceeded | Output | 1 Bit | DPT.1 | CT |
| 215 | E4 Heating temperature limit | Output | 1 Bit | DPT.1 | CT |
| 216 | E4 Save scene | Input | 1 Bit | DPT.1 | CW |
| 216 | E4 Enable save | Input | 1 Bit | DPT.1 | CW |
| 216 | E4 Switching step 5 | Output | 1 Bit | DPT.1 | CWT |
| 216 | E4 Switching, long actuation | Output | 1 Bit | DPT.1 | CWT |
| 216 | E4 Bit threshold value 1 | Output | 1 Bit | DPT.1 | CT |
| 216 | E4 Byte threshold value 1 | Output | 1 Byte | DPT.5 | CT |
| 216 | E4 2-byte threshold value 1 | Output | 2 Bytes | DPT.7 | CT |
| 216 | E4 Temperature threshold value 1 | Output | 2 Bytes | DPT.9 | CT |
| 217 | E4 Switch step UP/DOWN | Input | 1 Bit | DPT.1 | CW |
| 217 | E4 ZZ: Limit value exceeded | Output | 1 Bit | DPT.1 | CT |
| 217 | E4 Send if threshold value 1 undershot | Input | 1 Byte | DPT.5 | CW |
| 217 | E4 Send if threshold value 1 undershot | Input | 2 Bytes | DPT.7 | CW |
| 217 | E4 Send if threshold value 1 undershot | Input | 2 Bytes | DPT.9 | CW |
| 218 | E4 Actuating number | Input | 1 Byte | DPT.5 | CWTU |
| 218 | E4 ZZ: Request counter reading | Input | 1 Bit | DPT.1 | CW |
| 218 | E4 Send if threshold value 1 exceeded | Input | 1 Byte | DPT.5 | CW |
| 218 | E4 Send if threshold value 1 exceeded | Input | 2 Bytes | DPT.7 | CW |
| 218 | E4 Send if threshold value 1 exceeded | Input | 2 Bytes | DPT.9 | CW |
| 219 | E4 ZZ: Reverse direction | Input | 1 Bit | DPT.1 | CW |
| 220 | E4 ZZ: Reset | Input | 1 Bit | DPT.1 | CW |
| 220 | E4 Change temperature, tolerance band 1 lower limit | Input | 2 Bytes | DPT.9 | CW |
| 221 | E4 ZZ: Stop | Input | 1 Bit | DPT.1 | CW |
| 221 | E4 Change temperature, tolerance band 1 upper limit | Input | 2 Bytes | DPT.9 | CW |
| 222 | E4 Bit threshold value 2 | Output | 1 Bit | DPT.1 | CT |
| 222 | E4 Byte threshold value 2 | Output | 1 Byte | DPT.5 | CT |
| 222 | E4 2-byte threshold value 2 | Output | 2 Bytes | DPT.7 | CT |
| 222 | E4 Temperature threshold value 2 | Output | 2 Bytes | DPT.9 | CT |
| 223 | E4 Send if threshold value 2 undershot | Input | 1 Byte | DPT.5 | CW |
| 223 | E4 Send if threshold value 2 undershot | Input | 2 Bytes | DPT.7 | CW |
| 223 | E4 Send if threshold value 2 undershot | Input | 2 Bytes | DPT.9 | CW |
| 224 | E4 Send if threshold value 2 exceeded | Input | 1 Byte | DPT.5 | CW |
| 224 | E4 Send if threshold value 2 exceeded | Input | 2 Bytes | DPT.7 | CW |
| 224 | E4 Send if threshold value 2 exceeded | Input | 2 Bytes | DPT.9 | CW |
| 226 | E4 Change temperature, tolerance band 2 lower limit | Input | 2 Bytes | DPT.9 | CW |
| 227 | E4 Change temperature, tolerance band 2 upper limit | Input | 2 Bytes | DPT.9 | CW |
| 230 | E4 Disable | Input | 1 Bit | DPT.1 | CW |
| 232 | E5 Switching sensor | Output | 1 Bit | DPT.1 | CWT |
| 232 | E5 Alarm sensor | Output | 1 Bit | DPT.1 | CWT |
| 232 | E5 Switching | Output | 1 Bit | DPT.1 | CWT |
| 232 | E5 Blind UP/DOWN | Output | 1 Bit | DPT.1 | CWT |
| 232 | E5 Switch (event 0) | Output | 1 Bit | DPT.1 | CT |
| 232 | E5 Priority (event 0) | Output | 2 Bit | DPT.2 | CT |
| 232 | E5 1-byte value (-128 to 127) (event 0) | Output | 1 Byte | DPT.6 | CT |
| 232 | E5 1-byte value (0 to 255) (event 0) | Output | 1 Byte | DPT.5 | CT |
| 232 | E5 Scene (event 0) | Output | 1 Byte | DPT.18 | CT |
| 232 | E5 2-byte value (-32,768 to 32,767) (event 0) | Output | 2 Bytes | DPT.8 | CT |
| 232 | E5 2-byte value (0 to 65,535) (event 0) | Output | 2 Bytes | DPT.7 | CT |
| 232 | E5 4-byte value (-2,147,483,648 to 2,147,483,647) (event 0) | Output | 4 Bytes | DPT.13 | CT |
| 232 | E5 4-byte value (0 to 4294967295) (event 0) | Output | 4 Bytes | DPT.12 | CT |
| 232 | E5 2-byte floating point (event 0) | Output | 2 Bytes | DPT.9 | CT |
| 232 | E5 Scene | Output | 1 Byte | DPT.18 | CWTU |
| 232 | E5 Switching step 1 | Output | 1 Bit | DPT.1 | CWT |
| 232 | E5 Switching 1 actuation | Output | 1 Bit | DPT.1 | CWT |
| 232 | E5 HZ: Counter reading 1-byte value | Output | 1 Byte | DPT.6 | CT |
| 232 | E5 HZ: Counter reading 1-byte value | Output | 1 Byte | DPT.5 | CT |
| 232 | E5 HZ: Counter reading 2-byte value | Output | 2 Bytes | DPT.8 | CT |
| 232 | E5 HZ: Counter reading 2-byte value | Output | 2 Bytes | DPT.7 | CT |
| 232 | E5 HZ: Counter reading 4-byte value | Output | 4 Bytes | DPT.13 | CT |
| 233 | E5 Dimming | Output | 4 Bit | DPT.3 | CT |
| 233 | E5 STOP/slat adjustment | Output | 1 Bit | DPT.1 | CT |
| 233 | E5 Switch (event 1) | Output | 1 Bit | DPT.1 | CT |
| 233 | E5 Priority (event 1) | Output | 2 Bit | DPT.2 | CT |
| 233 | E5 1-byte value (-128 to 127) (event 1) | Output | 1 Byte | DPT.6 | CT |
| 233 | E5 1-byte value (0 to 255) (event 1) | Output | 1 Byte | DPT.5 | CT |
| 233 | E5 Scene (event 1) | Output | 1 Byte | DPT.18 | CT |
| 233 | E5 2-byte value (-32,768 to 32,767) (event 1) | Output | 2 Bytes | DPT.8 | CT |
| 233 | E5 2-byte value (0 to 65,535) (event 1) | Output | 2 Bytes | DPT.7 | CT |
| 233 | E5 4-byte value (-2,147,483,648 to 2,147,483,647) (event 1) | Output | 4 Bytes | DPT.13 | CT |
| 233 | E5 4-byte value (0 to 4294967295) (event 1) | Output | 4 Bytes | DPT.12 | CT |
| 233 | E5 2-byte floating point (event 1) | Output | 2 Bytes | DPT.9 | CT |
| 233 | E5 Switching step 2 | Output | 1 Bit | DPT.1 | CWT |
| 233 | E5 Switching 2 actuations | Output | 1 Bit | DPT.1 | CWT |
| 233 | E5 ZZ: Counter reading 1-byte value | Output | 1 Byte | DPT.6 | CT |
| 233 | E5 ZZ: Counter reading 1-byte value | Output | 1 Byte | DPT.5 | CT |
| 233 | E5 ZZ: Counter reading 2-byte value | Output | 2 Bytes | DPT.8 | CT |
| 233 | E5 ZZ: Counter reading 2-byte value | Output | 2 Bytes | DPT.7 | CT |
| 233 | E5 ZZ: Counter reading 4-byte value | Output | 4 Bytes | DPT.13 | CT |
| 234 | E5 Start event 0/1 | Input | 1 Bit | DPT.1 | CW |
| 234 | E5 Top end position | Input | 1 Bit | DPT.1 | CW |
| 234 | E5 Scene storage display | Output | 1 Bit | DPT.1 | CT |
| 234 | E5 Switching step 3 | Output | 1 Bit | DPT.1 | CWT |
| 234 | E5 Switching 3 actuations | Output | 1 Bit | DPT.1 | CWT |
| 234 | E5 HZ: Request counter reading | Input | 1 Bit | DPT.1 | CW |
| 235 | E5 Bottom end position | Input | 1 Bit | DPT.1 | CW |
| 235 | E5 Switching step 4 | Output | 1 Bit | DPT.1 | CWT |
| 235 | E5 Switching 4 actuations | Output | 1 Bit | DPT.1 | CWT |
| 235 | E5 HZ: Limit value exceeded | Output | 1 Bit | DPT.1 | CT |
| 236 | E5 Save scene | Input | 1 Bit | DPT.1 | CW |
| 236 | E5 Enable save | Input | 1 Bit | DPT.1 | CW |
| 236 | E5 Switching step 5 | Output | 1 Bit | DPT.1 | CWT |
| 236 | E5 Switching, long actuation | Output | 1 Bit | DPT.1 | CWT |
| 237 | E5 Switch step UP/DOWN | Input | 1 Bit | DPT.1 | CW |
| 237 | E5 ZZ: Limit value exceeded | Output | 1 Bit | DPT.1 | CT |
| 238 | E5 Actuating number | Input | 1 Byte | DPT.5 | CWTU |
| 238 | E5 ZZ: Request counter reading | Input | 1 Bit | DPT.1 | CW |
| 239 | E5 ZZ: Reverse direction | Input | 1 Bit | DPT.1 | CW |
| 240 | E5 ZZ: Reset | Input | 1 Bit | DPT.1 | CW |
| 241 | E5 ZZ: Stop | Input | 1 Bit | DPT.1 | CW |
| 250 | E5 Disable | Input | 1 Bit | DPT.1 | CW |
| 252 | CO2: absolute air pressure [Pa] | Input | 2 Bytes | DPT.9 | CW |
Parameters (478)
| Parameter | Type | Default |
|---|---|---|
| PID_HARDWARE_TYPE_PARAMETER | list | |
| Variant | list | Please select variant |
| PAR_CO2_CHANNEL_ACTIVE | list | inactive |
| PAR_CO2_AMPEL_USE | list | inactive |
| PAR_CO_CHANNEL_ACTIVE | list | inactive |
| PAR_CO_AMPEL_USE | list | inactive |
| PAR_FD_CHANNEL_ACTIVE | list | inactive |
| PAR_FD_AMPEL_USE | list | inactive |
| PAR_VOC_CHANNEL_ACTIVE | list | inactive |
| PAR_VOC_AMPEL_USE | list | inactive |
| PAR_RH_CHANNEL_ACTIVE | list | inactive |
| PAR_RH_AMPEL_USE | list | inactive |
| PAR_T_CHANNEL_ACTIVE | list | inactive |
| PAR_T_AMPEL_USE | list | inactive |
| PAR_DEWPOINT_CHANNEL_ACTIVE | list | inactive |
| PAR_PRESSURE_CHANNEL_ACTIVE | list | inactive |
| PAR_VAV_CHANNEL_ACTIVE | list | inactive |
| PAR_INPUT_CHANNEL_ACTIVE | list | inactive |
| PAR_OUTPUT_CHANNEL_ACTIVE | list | inactive |
| PAR_TOUCH_CHANNEL_ACTIVE | list | inactive |
| PAR_EXT_IN_CAP_COUPLING_ACTIVE | list | inactive |
| Send in operation | list | inactive |
| Send 'in operation' cyclically | list | every minute |
| Send delay after bus voltage recovery | unsignedInt 2…255 | 2 |
| CO2 sensor | list | enabled |
| Value offset | list | 0 ppm |
| PAR_DUMMY_PB_SENSOR_0_SETTINGSBLOCK_30 | unsignedInt 0…255 | 1 |
| PAR_DUMMY_HELP_PB_SENSOR_0_SETTINGSBLOCK_30 | unsignedInt 0…255 | 1 |
| Error CO2 sensor | list | don't notify |
| PAR_DUMMY_PB_SENSOR_0_SETTINGSBLOCK_40 | unsignedInt 0…255 | 1 |
| PAR_DUMMY_HELP_PB_SENSOR_0_SETTINGSBLOCK_40 | unsignedInt 0…255 | 1 |
| Enable calibration via bus | list | no |
| PAR_DUMMY_PB_SENSOR_0_SETTINGSBLOCK_50 | unsignedInt 0…255 | 1 |
| PAR_DUMMY_HELP_PB_SENSOR_0_SETTINGSBLOCK_50 | unsignedInt 0…255 | 1 |
| Send CO2 value when changing | list | disabled |
| Send CO2 value cyclically | list | every minute |
| external value | unsignedInt 0…255 | 0 |
| percentage | unsignedInt 0…255 | 0 |
| PAR_DUMMY_PB_SENSOR_0_SETTINGSBLOCK_70 | unsignedInt 0…255 | 1 |
| PAR_DUMMY_HELP_PB_SENSOR_0_SETTINGSBLOCK_70 | unsignedInt 0…255 | 1 |
| Send CO2 min/max values when changing | list | disabled |
| Send CO2 min/max values cyclically | list | disabled |
| PAR_DUMMY_PB_SENSOR_0_SETTINGSBLOCK_80 | unsignedInt 0…255 | 1 |
| PAR_DUMMY_HELP_PB_SENSOR_0_SETTINGSBLOCK_80 | unsignedInt 0…255 | 1 |
| LED visualisation type | list | LED green/yellow/red |
| Limit 1 (yellow) | list | 800 ppm |
| Limit 2 (red) | list | threshold 1 + 400 ppm |
| comfort zone low limit | list | 800 ppm |
| comfort zone high limit | list | threshold 1 + 400 ppm |
| Air pressure compensation of CO2 sensor | list | compensation with internal air pressure value |
| Altitude a. s. l. | unsignedInt 0…5000 | 700 |
| Type of CO2 control | list | disabled |
| PAR_CTL_0_ACT | list | disabled |
| PAR_CTL_0_VIS_STEP1 | list | disabled |
| PAR_CTL_0_VIS_STEP2 | list | disabled |
| PAR_CTL_0_VIS_STEP3 | list | disabled |
| PAR_CTL_0_VIS_ONE_STEP | list | disabled |
| PAR_CTL_0_SEND_CYCLIC_ACT | list | disabled |
| Allow to change base set-point via bus | list | no |
| Hysteresis (symmetrical) | list | 50 ppm |
| Control value output format | list | percent |
| Control value output format | list | switching command |
| PAR_CTL_0_ACTUATING_VAL_FORMAT | list | switching command |
| PAR_CTL_0_OUT_GO_NUMBER | unsignedInt 0…255 | 0 |
| PAR_CTL_0_SEND_BY_CHANGE_FORMAT | unsignedInt 0…255 | 0 |
| Sensor value 1 | list | internal sensor |
| Sensor value 2 | list | disabled |
| Sensor value 3 | list | disabled |
| Sensor value 4 | list | disabled |
| PAR_CTL_0_EXT_VALUE_CALC_TYPE_ACT | list | disabled |
| Value calculation type | list | Average |
| Weight value 1 | unsignedInt 0…10 | 1 |
| Weight value 2 | unsignedInt 0…10 | 1 |
| Weight value 3 | unsignedInt 0…10 | 1 |
| Weight value 4 | unsignedInt 0…10 | 1 |
| CO2 threshold 1 | list | 400 ppm |
| Switching command below threshold 1 | list | off |
| Switching command above threshold 1 | list | on |
| Control value in case of sensor error | list | off |
| Priority below threshold 1 | list | stop priority |
| Priority above threshold 1 | list | on with priority |
| Control value in case of sensor error | list | stop priority |
| Blocking object | list | disabled |
| Behavior when unblocking | list | don't send |
| Behavior when blocking | list | don't send |
| Switching command when blocking | list | off |
| Priority when blocking | list | stop priority |
| CO2 threshold 2 | list | threshold 1 + 400 ppm |
| Switching command below threshold 2 | list | off |
| Switching command above threshold 2 | list | on |
| Priority below threshold 2 | list | stop priority |
| Priority above threshold 2 | list | on with priority |
| CO2 threshold 3 | list | threshold 2 + 400 ppm |
| Switching command below threshold 3 | list | off |
| Switching command above threshold 3 | list | on |
| Priority below threshold 3 | list | stop priority |
| Priority above threshold 3 | list | on with priority |
| Value when below threshold 1 | unsignedInt 0…255 | 0 |
| Percent below threshold 1 | unsignedInt 0…100 | 0 |
| Scene below threshold 1 | unsignedInt 1…64 | 1 |
| Percent | unsignedInt 0…100 | 0 |
| Value | unsignedInt 0…255 | 0 |
| Scene | unsignedInt 1…64 | 1 |
| Control value in case of sensor error | unsignedInt 0…255 | 0 |
| Control value in case of sensor error | list | 0% |
| Scene in case of sensor error | unsignedInt 1…64 | 1 |
| Percent when blocking | unsignedInt 0…100 | 0 |
| Value when blocking | unsignedInt 0…255 | 0 |
| Scene when blocking | unsignedInt 1…64 | 1 |
| Set-point | list | 400 ppm |
| Proportional band | list | 500 ppm |
| Reset time | list | 15 min. |
| Min. control value | list | 0% |
| Min. control value | list | 0 |
| Max. control value | list | 100% |
| Max. control value | list | 255 |
| Send control value when change-over | list | disabled |
| Send control value when changing | list | disabled |
| send control value cyclically | list | every minute |
| Relative humidity sensor | list | disabled |
| Value offset | list | 0% |
| PAR_DUMMY_PB_SENSOR_1_SETTINGSBLOCK_30 | unsignedInt 0…255 | 1 |
| PAR_DUMMY_HELP_PB_SENSOR_1_SETTINGSBLOCK_30 | unsignedInt 0…255 | 1 |
| Error humidity sensor | list | don't notify |
| PAR_SENSOR_1_BUS_CALIBRATION_USE | list | no |
| PAR_DUMMY_PB_SENSOR_1_SETTINGSBLOCK_50 | unsignedInt 0…255 | 1 |
| PAR_DUMMY_HELP_PB_SENSOR_1_SETTINGSBLOCK_50 | unsignedInt 0…255 | 1 |
| Send relative humidity when changing | list | disabled |
| Send relative humidity cyclically | list | every minute |
| PAR_DUMMY_PB_SENSOR_1_SETTINGSBLOCK_70 | unsignedInt 0…255 | 1 |
| PAR_DUMMY_HELP_PB_SENSOR_1_SETTINGSBLOCK_70 | unsignedInt 0…255 | 1 |
| Send rH min/max values when changing | list | disabled |
| Send rH min/max values cyclically | list | disabled |
| PAR_DUMMY_PB_SENSOR_1_SETTINGSBLOCK_80 | unsignedInt 0…255 | 1 |
| PAR_DUMMY_HELP_PB_SENSOR_1_SETTINGSBLOCK_80 | unsignedInt 0…255 | 1 |
| LED visualisation type | list | LED green in comfort zone else red |
| Limit 1 (yellow) | list | 20% |
| Limit 2 (red) | list | threshold 1 + 10% |
| comfort zone low limit | list | 40% |
| comfort zone high limit | list | threshold 1 + 20% |
| Control type | list | disabled |
| PAR_CTL_1_ACT | list | disabled |
| PAR_CTL_1_VIS_STEP1 | list | disabled |
| PAR_CTL_1_VIS_STEP2 | list | disabled |
| PAR_CTL_1_VIS_STEP3 | list | disabled |
| PAR_CTL_1_VIS_ONE_STEP | list | disabled |
| PAR_CTL_1_SEND_CYCLIC_ACT | list | disabled |
| Hysteresis (symmetrical) | list | 5% |
| PAR_CTL_1_ACTUATING_VAL_FORMAT | list | switching command |
| PAR_CTL_1_OUT_GO_NUMBER | unsignedInt 0…255 | 0 |
| PAR_CTL_1_SEND_BY_CHANGE_FORMAT | unsignedInt 0…255 | 0 |
| PAR_CTL_1_EXT_VALUE_CALC_TYPE_ACT | list | disabled |
| rH threshold 1 | list | 20% |
| rH threshold 2 | list | threshold 1 + 10% |
| rH threshold 3 | list | threshold 2 + 10% |
| Set-point | list | 30% |
| Proportional band | list | 20% |
| Send control value cyclically | list | every minute |
| Comparator | list | disabled |
| Value 1 | list | internal sensor |
| Value 2 | list | absolute humidity in [g/m3] via bus (communication object) |
| Output when Value 1 < Value 2 | list | 0 (unblock) |
| Output when error | list | 1 (block) |
| Send output value when changing | list | disabled |
| Send output value cyclically | list | every minute |
| Temperature sensor | list | disabled |
| Value offset | signedInt -50…50 | 0 |
| PAR_DUMMY_PB_SENSOR_2_SETTINGSBLOCK_30 | unsignedInt 0…255 | 1 |
| PAR_DUMMY_HELP_PB_SENSOR_2_SETTINGSBLOCK_30 | unsignedInt 0…255 | 1 |
| Error temperature sensor | list | don't notify |
| PAR_SENSOR_2_BUS_CALIBRATION_USE | list | no |
| PAR_DUMMY_PB_SENSOR_2_SETTINGSBLOCK_50 | unsignedInt 0…255 | 1 |
| PAR_DUMMY_HELP_PB_SENSOR_2_SETTINGSBLOCK_50 | unsignedInt 0…255 | 1 |
| Send temperature when changing | list | disabled |
| Send temperature cyclically | list | every minute |
| External value | unsignedInt 0…255 | 0 |
| Percentage | unsignedInt 0…255 | 0 |
| PAR_DUMMY_PB_SENSOR_2_SETTINGSBLOCK_70 | unsignedInt 0…255 | 1 |
| PAR_DUMMY_HELP_PB_SENSOR_2_SETTINGSBLOCK_70 | unsignedInt 0…255 | 1 |
| Send min/max temperature values when changing | list | disabled |
| Send min/max temperature values cyclically | list | disabled |
| Frost alarm | list | disabled |
| Frost alarm when temperature | list | <1°C |
| Send frost alarm when change of status | list | enabled |
| Send frost alarm cyclically | list | every hour |
| Heat alarm | list | disabled |
| Heat alarm when temperature | list | >30°C |
| Send heat alarm when change of status | list | enabled |
| Send heat alarm cyclically | list | every hour |
| Select heating and/or cooling | list | inactive |
| PAR_RTR_ACT | list | disabled |
| PAR_RTR_ACT_MAIN_ST_HEAT | list | disabled |
| PAR_RTR_ACT_MAIN_ST_COOL | list | disabled |
| PAR_DUMMY_PB_RTR_CONFIGBLOCK_30 | unsignedInt 0…255 | 1 |
| PAR_DUMMY_HELP_PB_RTR_CONFIGBLOCK_30 | unsignedInt 0…255 | 1 |
| Extra level heating enable | list | disabled |
| Guide heating | list | disabled |
| Heating demand for display | list | no |
| Extra level cooling enable | list | disabled |
| Guide cooling | list | disabled |
| Cooling demand for display | list | no |
| Operating mode after reset | list | Comfort |
| Operating mode after ETS-download | list | Comfort |
| PAR_RTR_GUIDING_ACT | list | disabled |
| Comfort temperature | unsignedInt 0…400 | 210 |
| Standby setback heating below Comfort temp. | unsignedInt 0…100 | 0 |
| Eco setback heating below Comfort temp. | unsignedInt 0…100 | 0 |
| Frost protection temperature heating | unsignedInt 0…400 | 70 |
| Standby increment cooling above Comfort temp. (plus Dead zone) | unsignedInt 0…100 | 0 |
| Eco increment cooling above Comfort temp. (plus Dead zone) | unsignedInt 0…100 | 0 |
| Heat protection temperature cooling | unsignedInt 0…400 | 350 |
| Interval to main level heating | signedInt -100…0 | -10 |
| Interval to main level cooling | unsignedInt 0…100 | 10 |
| Send set-point temperature when changing | list | disabled |
| Send set-point temperature cyclically | list | disabled |
| PAR_DUMMY_PB_RTR_SET_TEMP_L2BLOCK_30 | unsignedInt 0…255 | 1 |
| PAR_DUMMY_HELP_PB_RTR_SET_TEMP_L2BLOCK_30 | unsignedInt 0…255 | 1 |
| Toggle between heating and cooling | list | Automatically (via controller) |
| Dead zone between heating and cooling | unsignedInt 0…100 | 20 |
| Min. guide value heating | signedInt -50…50 | 0 |
| Max. guide value heating | signedInt -50…50 | 0 |
| Max. increment of set-point for min. guide value heating | signedInt 0…10 | 0 |
| Min. guide value cooling | signedInt -50…50 | 0 |
| Max. guide value cooling | signedInt -50…50 | 0 |
| Max. setback of set-point for max. guide value cooling | signedInt 0…10 | 0 |
| Set-point override | list | disabled |
| Blocking object heating mode | list | disabled |
| Blocking object cooling mode: enable | list | disabled |
| Blocking object extra level heating: enable | list | disabled |
| Blocking object extra level cooling: enable | list | disabled |
| Temperature measurement value 1 | list | internal sensor |
| Temperature measurement value 2 | list | disabled |
| Temperature measurement value 3 | list | disabled |
| Temperature measurement value 4 | list | disabled |
| PAR_RTR_EXT_VALUE_CALC_TYPE_ACT | list | disabled |
| Man. adjustment range | list | +/-3K |
| LED's when disabled | list | all LED's off |
| LED's when blocked | list | all LED's off |
| Send man. offset upon change | list | disabled |
| Send man. offset cyclically | list | disabled |
| Party function | list | disabled |
| Party mode | list | Comfort mode |
| Duration limit | list | enabled |
| Duration | unsignedInt 1…1440 | 60 |
| Retrigger | list | disabled |
| Control type | list | PI |
| Control direction of control value | list | normal |
| Proportional band | unsignedInt 1…8 | 5 |
| Hysteresis (symmetrical) | unsignedInt 5…50 | 5 |
| PWM cycle | unsignedInt 5…30 | 5 |
| Control value in case of sensor error (0…255) | unsignedInt 0…255 | 0 |
| PAR_SEP_RTR_MAIN_ST_HEAT_40 | unsignedInt 0…255 | 1 |
| Send control value when changing | list | enabled |
| Send control value when blocked | list | don't send |
| Control value when blocked | list | 0% |
| Control value when blocked | unsignedInt 0…255 | 0 |
| Control value when blocked | list | off |
| PAR_SEP_RTR_EXTRA_ST_HEAT_40 | unsignedInt 0…255 | 1 |
| PAR_SEP_RTR_MAIN_ST_COOL_40 | unsignedInt 0…255 | 1 |
| PAR_SEP_RTR_EXTRA_ST_COOL_40 | unsignedInt 0…255 | 1 |
| Dew point sensor | list | disabled |
| Send dew point temp. when changing | list | disabled |
| Send dew point temp. cyclically | list | every minute |
| Dew point alarm | list | disabled |
| Dew point alarm advance | list | 1K |
| Dew point alarm hysteresis (symmetrical) | list | 1K hysteresis |
| Send dew point alarm when change of status | list | enabled |
| Send dew point alarm cyclically | list | every hour |
| Type of telegram for dew point alarm | list | switching command |
| Switching command when dew point alarm | list | on |
| Priority when dew point alarm | list | on with priority |
| Percent when dew point alarm (0…100%) | unsignedInt 0…100 | 100 |
| Value when dew point alarm (0…255) | unsignedInt 0…255 | 1 |
| Scene when dew point alarm (1...64) | unsignedInt 1…64 | 2 |
| Switching command at the end of dew point alarm | list | off |
| Priority at the end of dew point alarm | list | stop priority |
| Percent at the end of dew point alarm (0…100%) | unsignedInt 0…100 | 0 |
| Value at the end of dew point alarm (0…255) | unsignedInt 0…255 | 0 |
| Scene at the end of dew point alarm (1…64) | unsignedInt 1…64 | 1 |
| Air pressure sensor | list | disabled |
| Error air pressure sensor | list | don't notify |
| Send absolute air pressure when changing | list | disabled |
| Send absolute air pressure cyclically | list | every minute |
| Send relative air pressure when changing | list | disabled |
| Send relative air pressure cyclically | list | every minute |
| PAR_P_ACT_PREL | list | enabled |
| PAR_VAVC_PLUS_0_VIEW | list | disabled |
| Second VAV parameter set | list | inactive |
| PAR_VAVC_PLUS_0_ACT | list | disabled |
| PAR_VAVC_PLUS_0_MAIN_HEAT_VISIBLE | list | disabled |
| PAR_VAVC_PLUS_0_MAIN_COOL_VISIBLE | list | disabled |
| PAR_VAVC_PLUS_0_EXTRA_HEAT_VISIBLE | list | disabled |
| PAR_VAVC_PLUS_0_EXTRA_COOL_VISIBLE | list | disabled |
| PAR_VAVC_PLUS_0_EXTERN_0_VISIBLE | list | disabled |
| PAR_DUMMY_PB_VAVC_PLUS_0_SETTINGSBLOCK_SET_0 | unsignedInt 0…255 | 1 |
| PAR_DUMMY_HELP_PB_VAVC_PLUS_0_SETTINGSBLOCK_SET_0 | unsignedInt 0…255 | 1 |
| CO2 control include | list | disabled |
| Relative humidity control include | list | disabled |
| Main level heating include | list | disabled |
| Extra level heating include | list | disabled |
| Main level cooling include | list | disabled |
| Extra level cooling include | list | disabled |
| External object include | list | disabled |
| PAR_DUMMY_PB_VAVC_PLUS_0_SETTINGSBLOCK_SET_1 | unsignedInt 0…255 | 1 |
| PAR_DUMMY_HELP_PB_VAVC_PLUS_0_SETTINGSBLOCK_SET_1 | unsignedInt 0…255 | 1 |
| PAR_SEP_VAVC_PLUS_0_30 | unsignedInt 0…255 | 1 |
| PAR_SEP_VAVC_PLUS_0_30_WENN_CHOOSE | unsignedInt 0…255 | 1 |
| Send VAVC control value when changing | list | disabled |
| Send VAVC control value cyclically | list | every minute |
| PAR_SEP_VAVC_PLUS_0_40 | unsignedInt 0…255 | 1 |
| PAR_SEP_VAVC_PLUS_0_40_WENN_CHOOSE | unsignedInt 0…255 | 1 |
| Percent when blocking (0…100%) | unsignedInt 0…100 | 0 |
| Value when blocking (0…255) | unsignedInt 0…255 | 0 |
| Limit number of telegrams | list | inactive |
| Maximum number of sent telegrams | unsignedInt 1…255 | 20 |
| Maximum number of sent telegrams per | list | 1 s |
| Designation | text | |
| Function | list | inactive |
| Binary function | list | Switching/alarm |
| Switching/alarm sensor | list | Switch |
| Communication object DPT 1.001 | text | <--- |
| Communication object DPT 1.005 | text | <--- |
| Differentiation between short and long actuation | list | inactive |
| Contact opening -> event 0 contact closing -> event 1 | text | <--- |
| Short actuation -> event 0 long actuation -> event 1 | text | <--- |
| Long actuation from ... s | list | 0,4 |
| Activate minimum signal duration | list | inactive |
| At contact opening in value x 0.1 s (1 - 65,535) | unsignedInt 1…65535 | 10 |
| At contact closing in value x 0.1 s (1 - 65,535) | unsignedInt 1…65535 | 10 |
| Query input after download, ETS reset and bus voltage recovery | list | inactive |
| Inactive waiting time after bus voltage recovery in s (0 - 30,000) | unsignedInt 0…30000 | 0 |
| Input is being actuated | list | closed |
| Enable object 'Start event 0/1' | list | inactive |
| Reaction in case of event 0 | list | Off/alarm |
| Reaction in case of event 1 | list | On/no alarm |
| Cyclical sending | list | inactive |
| Telegram repeated every ... s | unsignedInt 1…65535 | 60 |
| at object value | list | On |
| Debouncing time ... ms | list | 50 |
| Enable object 'Disable' | list | inactive |
| Switching/dimming sensor | list | Dimmer/switch |
| At actuation: dimming direction | list | Switchover |
| At short actuation: switching | list | Switchover |
| At long actuation: dimming direction | list | Switchover after switching darker |
| Dimming procedure | list | Start/stop |
| Brightness change per sent telegram | list | 3,13% |
| Telegram repeated every ... s | list | 0,4 |
| Blind operating function | list | 2-push-button, standard |
| Brief actuation: STOP/stepwise Long actuation: move UP/DOWN | text | <--- |
| Short actuation: move UP/DOWN Long actuation: STOP/stepwise | text | <--- |
| One after another at actuation UP, STOP, DOWN, STOP | text | <--- |
| At actuation: move UP/DOWN STOP at end of actuation | text | <--- |
| At actuation: move UP/DOWN STOP at next actuation | text | <--- |
| At actuation: slat | text | <--- |
| Reaction at short actuation | list | Stop/slat OPEN |
| Reaction at long actuation | list | Up |
| Reaction at actuation | list | Up |
| Reaction at actuation | list | Stop/slat OPEN |
| 'Slat' telegram repeated every ... s | list | 0,4 |
| 'Slat' telegram repeated, every ... s | list | 0,4 |
| Reaction in case of event 0 | list | 1-byte value (0 to 255) |
| Sent value | list | On |
| Value | list | 0 |
| Sent value | signedInt -128…127 | 0 |
| Sent value | unsignedInt 0…255 | 0 |
| Sent value | unsignedInt 1…64 | 1 |
| Forced operation | list | Off |
| Sent value | signedInt -32768…32767 | 0 |
| Sent value | unsignedInt 0…65535 | 0 |
| Sent value | signedInt -2147483648…2147483647 | 0 |
| Sent value | unsignedInt 0…4294967295 | 0 |
| Sent value | float -670760.96…670433.28 | 20 |
| Reaction in case of event 1 | list | 1-byte value (0 to 255) |
| Sent value | list | Off |
| Scene number at actuation | unsignedInt 1…64 | 1 |
| Save scene | list | no |
| Long actuation from ... s | list | 3 |
| Number of steps | list | 3 |
| Switching sequence type | list | Activate/deactivate (one button) |
| Direction at actuation | list | switch up |
| Switching sequence like ...000>001>011>111>011>... | text | <--- |
| Switching sequence like 000>001>011>111 | text | <--- |
| Switching sequence like ...000>001>011>010>110>... | text | <--- |
| At contact opening in value x 0.1 s (1 - 65,535) | unsignedInt 1…65535 | 10 |
| At contact closing in value x 0.1 s (1 - 65,535) | unsignedInt 1…65535 | 10 |
| Max. number of actuations | list | 3 |
| Sent value | list | Switchover |
| Update and send at actuation | list | inactive |
| Maximum time between two actuations ... s | list | 0,5 |
| Additional object for long actuation | list | inactive |
| Sent value at long actuation | list | Switchover |
| Data type (main counter) | list | 4-byte value (-2,147,483,648 to 2,147,483,647) |
| Communication object DPT 6.010 | text | <--- |
| Communication object DPT 5.010 | text | <--- |
| Communication object DPT 8.001 | text | <--- |
| Communication object DPT 7.001 | text | <--- |
| Communication object DPT 13.001 | text | <--- |
| Limit value 1 | signedInt -128…127 | 0 |
| Limit value 2 | signedInt -128…127 | 127 |
| Limit value 1 | unsignedInt 0…255 | 0 |
| Limit value 2 | unsignedInt 0…255 | 255 |
| Limit value 1 | signedInt -32768…32767 | 0 |
| Limit value 2 | signedInt -32768…32767 | 32767 |
| Limit value 1 | unsignedInt 0…65535 | 0 |
| Limit value 2 | unsignedInt 0…65535 | 65535 |
| Limit value 1 | signedInt -2147483648…2147483647 | 0 |
| Limit value 2 | signedInt -2147483648…2147483647 | 2147483647 |
| Counting type | list | only in case of rising edge |
| Number of input pulses for a counting pulse | unsignedInt 1…10000 | 1 |
| Counter reading change per counting pulse | signedInt -10000…10000 | 1 |
| Send counter reading at download, ETS reset and bus voltage recovery | list | inactive |
| Send counter reading at change | list | inactive |
| Counter reading is sent, every | list | inactive |
| Save counter reading | list | inactive |
| Reset counter reading at download | list | inactive |
| Enable intermediate counter | list | inactive |
| Data type (intermediate counter) | list | 4-byte value (-2,147,483,648 to 2,147,483,647) |
| Behaviour if a limit value is exceeded/undershot | list | continue counting |
| Reverse counting direction | list | inactive |
| Sensor type | list | 1-10 V |
| Lower measuring limit in x% of effective range | unsignedInt 0…100 | 0 |
| Upper measuring limit in x% of effective range | unsignedInt 0…100 | 100 |
| Output value | list | 4-byte floating point |
| Output value to be sent at lower measuring limit | signedInt -128…127 | -128 |
| Output value to be sent at lower measuring limit | unsignedInt 0…255 | 0 |
| Output value to be sent at lower measuring limit | signedInt -32768…32767 | -32768 |
| Output value to be sent at lower measuring limit | unsignedInt 0…65535 | 0 |
| Output value to be sent at lower measuring limit | float -670760.96…670433.28 | 0 |
| Output value to be sent at lower measuring limit | float -3.4028234e+38…3.4028234e+38 | 0 |
| Output value to be sent at upper measuring limit | signedInt -128…127 | 127 |
| Output value to be sent at upper measuring limit | unsignedInt 0…255 | 255 |
| Output value to be sent at upper measuring limit | signedInt -32768…32767 | 32767 |
| Output value to be sent at upper measuring limit | unsignedInt 0…65535 | 65535 |
| Output value to be sent at upper measuring limit | float -670760.96…670433.28 | 0 |
| Output value to be sent at upper measuring limit | float -3.4028234e+38…3.4028234e+38 | 0 |
| Filters | list | inactive |
| Output value is sent from x% change in output range | list | if change above 2% |
| Output value is sent, every | list | inactive |
| Use threshold value | list | inactive |
| Send threshold at change | list | enabled |
| Send if threshold value undershot, every | list | inactive |
| Send if threshold value exceeded, every | list | inactive |
| Tolerance band lower limit in x% of output range | unsignedInt 0…100 | 0 |
| Tolerance band upper limit in x% of output range | unsignedInt 0…100 | 100 |
| Limit value changeable via bus | list | inactive |
| Data type of threshold value object | list | 1 bit |
| Send if threshold value undershot | list | Send OFF telegram |
| Send if threshold value exceeded | list | Send ON telegram |
| Minimum duration of undershoot | list | inactive |
| Minimum duration of overshoot | list | inactive |
| Send if threshold value undershot | unsignedInt 0…255 | 0 |
| Send if threshold value exceeded | unsignedInt 0…255 | 0 |
| Send if threshold value undershot | unsignedInt 0…65535 | 0 |
| Send if threshold value exceeded | unsignedInt 0…65535 | 0 |
| Send if threshold value undershot [0.1°C] | signedInt -500…1500 | 0 |
| Send if threshold value exceeded [0.1°C] | signedInt -500…1500 | 0 |
| Suppression stage | list | weak |
| E4/5 Temperature function | list | Temperature |
| Temperature sensor type | list | PT1000 |
| Temperature offset in K | list | 0 |
| Line fault compensation | list | None |
| Line length, single distance ... in m | unsignedInt 1…30 | 10 |
| Cross-section of the busbar, value * 0.01 mm2 | unsignedInt 1…150 | 100 |
| Line resistance in milliohm [sum of feed and return conductors] | unsignedInt 0…10000 | 500 |
| Output value sent from a change of [x 0.1°C] | list | disabled |
| Heat | list | active |
| Value [°C] | unsignedInt 10…60 | 35 |
| Hysteresis [°C] | list | 1,5 |
| Enable threshold value 1 function | list | inactive |
| Enable threshold value 2 function | list | inactive |
| Tolerance band lower limit [0.1°C] | signedInt -500…1500 | -500 |
| Tolerance band upper limit [0.1°C] | signedInt -500…1500 | 1500 |
| Send if threshold value undershot | list | Send ON telegram |
| Send if threshold value undershot [0.1°C] | signedInt -500…1500 | 0 |
| Send if threshold value exceeded [0.1°C] | signedInt -500…1500 | 0 |
| Send if threshold value undershot | list | disabled |
| Send if threshold value exceeded | list | disabled |
| Limits changeable via bus | list | inactive |
Version history
| Application | App no | Fingerprint | First seen | Size | File |
|---|---|---|---|---|---|
| GS41.11 ets 2.0 latest | $0001 | 6216 | 2026-11-25 | 451 KB | Download |
About this file
This is the official ETS product database for the Hugo Müller GmbH & Co KG [GS 40.01 knx] Room climate, CO2, humidity, temperature controllers (GS40.01 knx), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.
More from Hugo Müller GmbH & Co KG
- [GS 30.12] Room climate-, humidity-, temperature controller GS 30.12 knx
- [GS 31.12] Room climate-, humidity-, temperature controller GS 31.12 knx
- [GS 37.11 knx] Room climate, humidity, temperature controllers GS 37.11 knx
- [GS 38.11 knx] Room climate, humidity, temperature controllers GS 38.11 knx
- [GS 40.12] Room climate, CO2, humidity, temperature controller GS 40.12 knx
- [GS 41.12] Room climate, CO2, humidity, temperature controller GS 41.12 knx
- [GS 47.11 knx] Room climate, CO2, humidity, temperature controllers GS 47.11 knx
- [GS 48.11 knx] Room climate, CO2, humidity, temperature controllers GS 48.11 knx
- [GS 30.11 knx] Room climate, humidity, temperature controllers GS30.11 knx
- [GS 31.11 knx] Room climate, humidity, temperature controllers GS31.11 knx
- [GS 40.11 knx] Room climate, CO2, humidity, temperature controllers GS40.11 knx
- [GS 41.01 knx] Room climate, CO2, humidity, temperature controllers GS41.01 knx