KNX Database
HDL MWC1KT10D2309 MWC1-KT.10

MWC1-KT.10 MWC1KT10D2309

HDL · Order number MWC1KT10D2309 · Motor

Curtain Motor - KNX

Download .knxprod Curtain Motor(V1.0) 1.0 · 132 KB

Product

ManufacturerHDL
Product nameMWC1-KT.10
Order numberMWC1KT10D2309
HardwareMWC1-KT.10
MediumTwisted Pair
Bus current (mA)8
Rail mountedNo
RegistrationCertified · 2024-05-06
Languagesen-US, zh-CN
Catalog entryM-0073_H-MWC1KT10D2309-10_HP-2300-10-CABA_CI-MWC1KT10D2309-1
FingerprintCABA
SHA-256a8e041a41574155859e83cd2bb4edc7930022d960ac093f2abd5c58edac1e667
First seen2026-11-25
Markets69 markets

Application program: Curtain Motor(V1.0) 1.0

Application number$2300
Version1.0
Mask versionMV-07B0 (System B)
KNX Data SecureNo
Minimum ETS version3.0f
Parameters187
Group objects56
Group objects (56)
NoNameFunctionSizeDPTFlags
1System function1-open(100%),0-close(0%)1 Bit1.19 window/doorCWU
1System function0-open(100%),1-close(0%)1 Bit1.19 window/doorCWU
2System functionStop ('0'/'1'-stop)1 Bit1.7 stepCWU
3System functionPercentage set1 Byte5.1 percentage (0..100%)CWU
4Heartbeat telegramSend "0" periodically1 Bit1.3 enableCT
4Heartbeat telegramSend "1" periodically1 Bit1.3 enableCT
4Heartbeat telegramSend "1/0" alternately1 Bit1.3 enableCT
5XX1 Bit1.1 switchCWT
6Limitation point set'1'-set open limitation1 Bit1.11 stateCWU
7Limitation point set'1'-set close limitation1 Bit1.11 stateCWU
8Reset limitation point'1'-reset limitation1 Bit1.11 stateCWU
9Short drag function'1'-Enable,'0'-disable1 Bit1.3 enableCWU
10Open/close state reportDepends on control settings1 Bit1.19 window/doorCRT
11Stop state report'1'-stop1 Bit1.7 stepCRT
11Stop state report'0'-stop1 Bit1.7 stepCRT
12Percentage state reportPercentage1 Byte5.1 percentage (0..100%)CRT
13Set preset position'0'-preset 1,'1'-preset 21 Bit1.22 sceneCWU
14Set preset position'0'-preset 3,'1'-preset 41 Bit1.22 sceneCWU
15Move to preset position'0'-preset 1,'1'-preset 21 Bit1.22 sceneCWU
16Move to preset position'0'-preset 3,'1'-preset 41 Bit1.22 sceneCWU
17Preset reportReport '1' after operation1 Bit1.11 stateCRT
17Preset reportReport '0' after operation1 Bit1.11 stateCRT
18Enable/Disable safety mode'1'-Enable,'0'-Disable1 Bit1.3 enableCWTU
19Report of safety mode'1'-Enabled,'0'-Disabled1 Bit1.3 enableCRT
20Alarm of weak wind'0'-No alarm,'1'-Alarm1 Bit1.5 alarmCWTU
20Alarm of weak wind'1'-No alarm,'0'-Alarm1 Bit1.5 alarmCWTU
21Alarm of slight wind'0'-No alarm,'1'-Alarm1 Bit1.5 alarmCWTU
21Alarm of slight wind'1'-No alarm,'0'-Alarm1 Bit1.5 alarmCWTU
22Alarm of strong wind'0'-No alarm,'1'-Alarm1 Bit1.5 alarmCWTU
22Alarm of strong wind'1'-No alarm,'0'-Alarm1 Bit1.5 alarmCWTU
23Report after wind alarm reactionReport '1' after operation1 Bit1.11 stateCRT
23Report after wind alarm reactionReport '0' after operation1 Bit1.11 stateCRT
24Rain alarm'0'-No alarm,'1'-Alarm1 Bit1.5 alarmCWTU
24Rain alarm'1'-No alarm,'0'-Alarm1 Bit1.5 alarmCWTU
25Report after rain alarm reactionReport '1' after operation1 Bit1.11 stateCRT
25Report after rain alarm reactionReport '0' after operation1 Bit1.11 stateCRT
26Frost alarm'0'-No alarm,'1'-Alarm1 Bit1.5 alarmCWTU
26Frost alarm'1'-No alarm,'0'-Alarm1 Bit1.5 alarmCWTU
27Report after frost alarm reactionReport '1' after operation1 Bit1.11 stateCRT
27Report after frost alarm reactionReport '0' after operation1 Bit1.11 stateCRT
28Enable/Disable auto1'1'-Enable,'0'-Disable1 Bit1.3 enableCWTU
29Report of auto1'1'-Enabled,'0'-Disabled1 Bit1.3 enableCRT
30Auto1Sun-"0"/"1"1 Bit1.1 switchCWTU
31Enable/Disable auto2'1'-Enable,'0'-Disable1 Bit1.3 enableCWU
32Report of auto2'1'-Enabled,'0'-Disabled1 Bit1.3 enableCRT
33Auto2 presence check'1'-presence,'0'-absence1 Bit1.2 booleanCWTU
34Auto2Heating-"0"/"1"1 Bit1.2 booleanCWTU
35Auto2Cooling-"0"/"1"1 Bit1.2 booleanCWTU
36Scene controlCall/Save scene number1 Byte18.1 scene controlCWU
37Scene reportReport '1' after operation1 Bit1.11 stateCRT
37Scene reportReport '0' after operation1 Bit1.11 stateCRT
38Forced controlForced operation 1(2 bit)2 Bit2.8 direction control 1CWTU
39Forced controlForced operation 2(1 bit)1 Bit1.1 switchCWTU
40Forced controlForced operation 3(1 bit)1 Bit1.1 switchCWTU
41Forced operation reportReport '1' after operation1 Bit1.11 stateCRT
41Forced operation reportReport '0' after operation1 Bit1.11 stateCRT
Parameters (106)
ParameterTypeDefault
Operation delay after recovered(1..255s)unsignedInt 1…2551
Heartbeat telegramlistDisable
Period of heartbeat transmission(1..65535s)unsignedInt 1…655351
Detection form of bus voltagelistDisable
The hightest normal voltage(value*0.1V)unsignedInt 0…6032
The lowest normal voltage(value*0.1V)unsignedInt 0…6020
Way of detection reportlistReport after changed
Detection report period(1..255s)unsignedInt 1…2551
Set/Reset limitation point via buslistDisable
Moving automatically after short draglistEnable
Enable/Disable short drag function via buslistDisable
Running directionlistForward
Report state after finished runninglistEnable
Report stop state after stoppedlistReport '1'
Report percentage state after finished change percentagelistEnable
Automatically measure travel after downloading the databaselistEnable
Control settinglist'1'-open(100%),'0'-close(0%)
Motor operation type after voltage recoverlistNo action
Preset positionlistDisable
Safety controllistDisable
Auto1 for sunlistDisable
Auto2 for cooling and heatinglistDisable
Scene controllistDisable
Forced controllistDisable
Preset position 1list0%(close)
Preset position 2list25%
Preset position 3list50%
Preset position 4list100%(open)
Set preset position(1 bit)listDisable
Move to preset position(1 bit)listDisable
Preset reportlistDisable
Enable/Disable safety mode via buslistDisable
Report after safety mode enabled/disabledlistDisable
Enable wind alarmlistEnable
Alarm of weak windlist'1'-No alarm,'0'-Alarm
Reaction on weak wind alarmlistPreset position 3
Position for weak wind alarmlist90%
Alarm of slight windlist'1'-No alarm,'0'-Alarm
Reaction on slight wind alarmlistPreset position 2
Position for slight wind alarmlist75%
Alarm of strong windlist'1'-No alarm,'0'-Alarm
Reaction on strong wind alarmlistPreset position 1
Position for strong wind alarmlist0%(close)
Reaction on reset wind alarmlistPreset position 4
Position for reset wind alarmlist100%(open)
Report after wind alarm reactionlistDisable
Enable rain alarmlistEnable
Rain alarmlist'1'-No alarm,'0'-Alarm
Reaction on rain alarmlistPreset position 1
Position for rain alarmlist0%(close)
Reaction on reset rain alarmlistPreset position 4
Position for reset rain alarmlist100%(open)
Report after rain alarm reactionlistDisable
Enable frost alarmlistEnable
Frost alarmlist'1'-No alarm,'0'-Alarm
Reaction on frost alarmlistPreset position 1
Position for frost alarmlist0%(close)
Reaction on reset frost alarmlistPreset position 4
Position for reset frost alarmlist100%(open)
Report after frost alarm reactionlistDisable
Priority for alarmslistFrost>Rain>Wind
Safety mode after voltage recoverlistInvalid
Read alarm status after voltage recoverlistDisable
Delay for reading alarm status(2..255S)unsignedInt 2…2552
If status have no update then repeatedly read(1 time/s)list2 times
Enable/Disable auto1 via buslistDisable
Report after auto1 enabledlistDisable
Delay for sun='0' (0..3600s)unsignedInt 0…36000
Delay for sun='1' (0..3600s)unsignedInt 0…36000
Reaction on sun='0'listNo reaction
Position for sun='0'list100%(open)
Reaction on sun='1'listNo reaction
Position for sun='1'list100%(open)
Auto1 mode after voltage recoverlistInvalid
Read auto1 status after voltage recoverlistDisable
Delay for reading auto1 status(2..255S)unsignedInt 2…2552
Enable/Disable auto2 via buslistDisable
Report after auto2 enabledlistDisable
Auto switch for presence check('1'-presence,'0'-absence)list'0'-auto1,'1'-auto2
Delay for switch to auto1(0..3600s)unsignedInt 0…36000
Delay for switch to auto2(0..3600s)unsignedInt 0…36000
Reaction when heating='1' and sun='0'listNo reaction
Position when heating='1' and sun='0'list100%(open)
Reaction when heating='1' and sun='1'listNo reaction
Position when heating='1' and sun='1'list50%
Reaction when cooling='1' and sun='0'listNo reaction
Position when cooling='1' and sun='0'list0%(close)
Reaction when cooling='1' and sun='1'listNo reaction
Position when cooling='1' and sun='1'list50%
Output is assigned to(scene 1..64)listInvalid
Reaction on output positionlistNo reaction
Output positionlist100%(open)
Output delaylistDisable
Delay(0..255 Min)unsignedInt 0…2550
Delay(0..59 Sec)unsignedInt 0…590
Scene reportlistDisable
Forced operation 1(2 bit)listEnable
Forced operation 2(1 bit)listEnable
Reaction on forced output positionlistPreset position 3
Output positionlist0%(close)
Forced operation 3(1 bit)listEnable
Reaction after exit from forced operationlistLast position
Forced operation after voltage recoverlistInvalid
Read forced operation status after voltage recoverlistDisable
Delay for reading forced operation status(2..255S)unsignedInt 2…2552
Forced operation reportlistDisable

Version history

ApplicationApp noFingerprintFirst seenSizeFile
Curtain Motor(V1.0) 1.0 latest$2300CABA2026-11-25132 KBDownload

About this file

This is the official ETS product database for the HDL MWC1-KT.10 (MWC1KT10D2309), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.