4-fold push button RF battery WKT304R
Hager Electro · Order number WKT304R · Produits radio › Appareillage
WKT304R
Download .knxprod SWKT304R 1.0 · 166 KB
Product
| Manufacturer | Hager Electro |
|---|---|
| Product name | 4-fold push button RF battery |
| Order number | WKT304R |
| Product text | 4 boutons poussoirs pile radio |
| Hardware | WKT304R |
| Medium | Twisted Pair |
| Rail mounted | No |
| Registration | Registered |
| Languages | fr-FR, de-DE, en-US, es-ES, it-IT, nl-NL, pt-PT |
| Catalog entry | M-0009_H-9.20.2F.2F.20WKT304R-1_HP-3019-10-EB0A_CI-WKT304R-1 |
| Fingerprint | EB0A |
| SHA-256 | 6e757f19c7191cb0a66bc94b3e1b5215dc847a8af89dbddab8835e097e8ec241 |
| First seen | 2026-11-25 |
| Markets | 69 markets |
Application program: SWKT304R 1.0
| Application number | $3019 |
|---|---|
| Version | 1.0 |
| Mask version | MV-0701 (7.1) |
| KNX Data Secure | No |
| Minimum ETS version | 3.0f |
| Parameters | 85 |
| Group objects | 73 |
Group objects (73)
| No | Name | Function | Size | DPT | Flags |
|---|---|---|---|---|---|
| 1 | Entrée 2 | ON / OFF | 1 Bit | CRT | |
| 1 | Entrée 2 | Inclinaison lamelles / Stop | 1 Bit | CRT | |
| 1 | Entrée 2 | Minuterie | 1 Bit | CRT | |
| 1 | Entrée 2 | Alarme 1 | 1 Bit | CRT | |
| 1 | Entrée 2 | Alarme 2 | 1 Bit | CRT | |
| 2 | Entrée 2 | Montée / Descente | 1 Bit | CRT | |
| 3 | Entrée 2 | Forçage | 2 Bit | CRT | |
| 4 | Entrée 2 | Variation | 4 Bit | CRT | |
| 5 | Entrée 2 | Sélection de consigne | 1 Byte | CRT | |
| 5 | Entrée 2 | Scène 1 | 1 Byte | CRT | |
| 5 | Entrée 2 | Scène 2 | 1 Byte | CRT | |
| 5 | Entrée 2 | Scène 3 | 1 Byte | CRT | |
| 5 | Entrée 2 | Scène 4 | 1 Byte | CRT | |
| 5 | Entrée 2 | Scène 5 | 1 Byte | CRT | |
| 5 | Entrée 2 | Scène 6 | 1 Byte | CRT | |
| 5 | Entrée 2 | Scène 7 | 1 Byte | CRT | |
| 5 | Entrée 2 | Scène 8 | 1 Byte | CRT | |
| 5 | Entrée 2 | Simulation de présence | 1 Byte | CRT | |
| 7 | Entrée 1 | ON / OFF | 1 Bit | CRT | |
| 7 | Entrée 1 | Inclinaison lamelles / Stop | 1 Bit | CRT | |
| 7 | Entrée 1 | Minuterie | 1 Bit | CRT | |
| 7 | Entrée 1 | Alarme 1 | 1 Bit | CRT | |
| 7 | Entrée 1 | Alarme 2 | 1 Bit | CRT | |
| 8 | Entrée 1 | Montée / Descente | 1 Bit | CRT | |
| 9 | Entrée 1 | Forçage | 2 Bit | CRT | |
| 10 | Entrée 1 | Variation | 4 Bit | CRT | |
| 11 | Entrée 1 | Sélection de consigne | 1 Byte | CRT | |
| 11 | Entrée 1 | Scène 1 | 1 Byte | CRT | |
| 11 | Entrée 1 | Scène 2 | 1 Byte | CRT | |
| 11 | Entrée 1 | Scène 3 | 1 Byte | CRT | |
| 11 | Entrée 1 | Scène 4 | 1 Byte | CRT | |
| 11 | Entrée 1 | Scène 5 | 1 Byte | CRT | |
| 11 | Entrée 1 | Scène 6 | 1 Byte | CRT | |
| 11 | Entrée 1 | Scène 7 | 1 Byte | CRT | |
| 11 | Entrée 1 | Scène 8 | 1 Byte | CRT | |
| 11 | Entrée 1 | Simulation de présence | 1 Byte | CRT | |
| 13 | Entrée 4 | ON / OFF | 1 Bit | CRT | |
| 13 | Entrée 4 | Inclinaison lamelles / Stop | 1 Bit | CRT | |
| 13 | Entrée 4 | Minuterie | 1 Bit | CRT | |
| 13 | Entrée 4 | Alarme 1 | 1 Bit | CRT | |
| 13 | Entrée 4 | Alarme 2 | 1 Bit | CRT | |
| 14 | Entrée 4 | Montée / Descente | 1 Bit | CRT | |
| 15 | Entrée 4 | Forçage | 2 Bit | CRT | |
| 16 | Entrée 4 | Variation | 4 Bit | CRT | |
| 17 | Entrée 4 | Sélection de consigne | 1 Byte | CRT | |
| 17 | Entrée 4 | Scène 1 | 1 Byte | CRT | |
| 17 | Entrée 4 | Scène 2 | 1 Byte | CRT | |
| 17 | Entrée 4 | Scène 3 | 1 Byte | CRT | |
| 17 | Entrée 4 | Scène 4 | 1 Byte | CRT | |
| 17 | Entrée 4 | Scène 5 | 1 Byte | CRT | |
| 17 | Entrée 4 | Scène 6 | 1 Byte | CRT | |
| 17 | Entrée 4 | Scène 7 | 1 Byte | CRT | |
| 17 | Entrée 4 | Scène 8 | 1 Byte | CRT | |
| 17 | Entrée 4 | Simulation de présence | 1 Byte | CRT | |
| 19 | Entrée 3 | ON / OFF | 1 Bit | CRT | |
| 19 | Entrée 3 | Inclinaison lamelles / Stop | 1 Bit | CRT | |
| 19 | Entrée 3 | Minuterie | 1 Bit | CRT | |
| 19 | Entrée 3 | Alarme 1 | 1 Bit | CRT | |
| 19 | Entrée 3 | Alarme 2 | 1 Bit | CRT | |
| 20 | Entrée 3 | Montée / Descente | 1 Bit | CRT | |
| 21 | Entrée 3 | Forçage | 2 Bit | CRT | |
| 22 | Entrée 3 | Variation | 4 Bit | CRT | |
| 23 | Entrée 3 | Sélection de consigne | 1 Byte | CRT | |
| 23 | Entrée 3 | Scène 1 | 1 Byte | CRT | |
| 23 | Entrée 3 | Scène 2 | 1 Byte | CRT | |
| 23 | Entrée 3 | Scène 3 | 1 Byte | CRT | |
| 23 | Entrée 3 | Scène 4 | 1 Byte | CRT | |
| 23 | Entrée 3 | Scène 5 | 1 Byte | CRT | |
| 23 | Entrée 3 | Scène 6 | 1 Byte | CRT | |
| 23 | Entrée 3 | Scène 7 | 1 Byte | CRT | |
| 23 | Entrée 3 | Scène 8 | 1 Byte | CRT | |
| 23 | Entrée 3 | Simulation de présence | 1 Byte | CRT | |
| 24 | Indication d'état | Etat batterie | 1 Bit | CRT |
Parameters (5)
| Parameter | Type | Default |
|---|---|---|
| Type de canal | list | Par défaut |
| Version du logiciel d'application | text | 1.0.8 |
| Description | list | |
| WKT304R_1036.pdf | list | |
| img\WKT304R.jpg | list |
Version history
| Application | App no | Fingerprint | First seen | Size | File |
|---|---|---|---|---|---|
| SWKT304R 2.0 latest | $3039 | 207E | 2026-11-25 | 199 KB | Download |
| SWKT304R 1.0 | $3019 | EB0A | 2026-11-25 | 166 KB | Download |
About this file
This is the official ETS product database for the Hager Electro 4-fold push button RF battery (WKT304R), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.
More from Hager Electro
- EHZ energy data sender EHZ503
- Smoke detector TG51x
- Heatstroke TG54x
- Media coupler TR131
- Hager RF to KNX TP coupler TR131N
- 1-output Lighting embedded RF TRB201
- Dimmer 1x 200W RF TRB210
- 1-output Shutters / blinds embedded RF TRB221
- 1-fold blind/shutter actuator 5A 230V AC, embedded TRB221A
- 2-input modules embedded battery RF TRB302A
- 2-input modules embedded 230V~ RF TRB302B
- 1-fold input / 1-fold output embedded RF TRB501