4-channel analog input TYF784

Hager Electro · Order number TYF784 · Inputs › 4-channel analog input

TYF784

Download .knxprod STYF784 0.1 · 110 KB

Product

ManufacturerHager Electro
Product name4-channel analog input
Order numberTYF784
HardwareAnalogeingang 4 fach
MediumTwisted Pair
Rail mountedYes
RegistrationCertified
Languagesfr-FR, de-DE, en-US
Catalog entryM-0009_H-9.20.2F.2F.20TYF784-1-O00F4_HP-209F-01-BB39-O00F4_CI-TYF784-1
FingerprintBB39
SHA-256e417cad0009ef3e74d9acc368cab8665f3a44e0fbbf1c3db407f861edfa2d78d
First seen2026-11-25
Markets69 markets

Application program: STYF784 0.1

Application number$209F
Version0.1
Mask versionMV-0701 (7.1)
KNX Data SecureNo
Parameters550
Group objects74
Group objects (74)
NoNameFunctionSizeDPTFlags
0Alarm objectAnalog input1 BitCTU
1Measuring value input 1Analog input2 BytesCTU
1Measuring value input 1Analog input1 ByteCTU
2Measuring value input 2Analog input2 BytesCTU
2Measuring value input 2Analog input1 ByteCTU
3Measuring value input 3Analog input2 BytesCTU
3Measuring value input 3Analog input1 ByteCTU
4Measuring value input 4Analog input2 BytesCTU
4Measuring value input 4Analog input1 ByteCTU
5Limit value 1 input 1Analog input1 BitCTU
6Limit value 2 input 1Analog input1 BitCTU
7Limit value 1 input 2Analog input1 BitCTU
8Limit value 2 input 2Analog input1 BitCTU
9Limit value 1 input 3Analog input1 BitCTU
10Limit value 2 input 3Analog input1 BitCTU
11Limit value 1 input 4Analog input1 BitCTU
12Limit value 2 input 4Analog input1 BitCTU
13External limit value 1 input 1Analog input1 ByteCWU
13External limit value 1 input 1Analog input2 BytesCWU
14External limit value 2 input 1Analog input2 BytesCWU
14External limit value 2 input 1Analog input1 ByteCWU
15External limit value 1 input 2Analog input1 ByteCWU
15External limit value 1 input 2Analog input2 BytesCWU
16External limit value 2 input 2Analog input2 BytesCWU
16External limit value 2 input 2Analog input1 ByteCWU
17External limit value 1 input 3Analog input1 ByteCWU
17External limit value 1 input 3Analog input2 BytesCWU
18External limit value 2 input 3Analog input2 BytesCWU
18External limit value 2 input 3Analog input1 ByteCWU
19External limit value 1 input 4Analog input1 ByteCWU
19External limit value 1 input 4Analog input2 BytesCWU
20External limit value 2 input 4Analog input2 BytesCWU
20External limit value 2 input 4Analog input1 ByteCWU
21Open-circuit monitoring input 1Analog input1 BitCTU
22Open-circuit monitoring input 2Analog input1 BitCTU
23Open-circuit monitoring input 3Analog input1 BitCTU
24Open-circuit monitoring input 4Analog input1 BitCTU
25Alarm objectExtension module1 BitCTU
26Measuring value input 5Extension module2 BytesCTU
26Measuring value input 5Extension module1 ByteCTU
27Measuring value input 6Extension module2 BytesCTU
27Measuring value input 6Extension module1 ByteCTU
28Measuring value input 7Extension module2 BytesCTU
28Measuring value input 7Extension module1 ByteCTU
29Measuring value input 8Extension module2 BytesCTU
29Measuring value input 8Extension module1 ByteCTU
30Limit value 1 input 5Extension module1 BitCTU
31Limit value 2 input 5Extension module1 BitCTU
32Limit value 1 input 6Extension module1 BitCTU
33Limit value 2 input 6Extension module1 BitCTU
34Limit value 1 input 7Extension module1 BitCTU
35Limit value 2 input 7Extension module1 BitCTU
36Limit value 1 input 8Extension module1 BitCTU
37Limit value 2 input 8Extension module1 BitCTU
38External limit value 1 input 5Extension module1 ByteCWU
38External limit value 1 input 5Extension module2 BytesCWU
39External limit value 2 input 5Extension module2 BytesCWU
39External limit value 2 input 5Extension module1 ByteCWU
40External limit value 1 input 6Extension module1 ByteCWU
40External limit value 1 input 6Extension module2 BytesCWU
41External limit value 2 input 6Extension module2 BytesCWU
41External limit value 2 input 6Extension module1 ByteCWU
42External limit value 1 input 7Extension module1 ByteCWU
42External limit value 1 input 7Extension module2 BytesCWU
43External limit value 2 input 7Extension module2 BytesCWU
43External limit value 2 input 7Extension module1 ByteCWU
44External limit value 1 input 8Extension module1 ByteCWU
44External limit value 1 input 8Extension module2 BytesCWU
45External limit value 2 input 8Extension module2 BytesCWU
45External limit value 2 input 8Extension module1 ByteCWU
46Open-circuit monitoring input 5Extension module1 BitCTU
47Open-circuit monitoring input 6Extension module1 BitCTU
48Open-circuit monitoring input 7Extension module1 BitCTU
49Open-circuit monitoring input 8Extension module1 BitCTU
Parameters (57)
ParameterTypeDefault
General parameterslistno
Signal input 1listno sensor
Open-circuit detection input 1listno detection
Signal input 2listno sensor
Open-circuit detection input 2listno detection
Signal input 3listno sensor
Open-circuit detection input 3listno detection
Signal input 4listno sensor
Open-circuit detection input 4listno detection
Alarm analog inputlistno transmission
Extension modulelistno
Signal input 5listno sensor
Open-circuit detection input 5listno detection
Signal input 6listno sensor
Open-circuit detection input 6listno detection
Signal input 7listno sensor
Open-circuit detection input 7listno detection
Signal input 8listno sensor
Open-circuit detection input 8listno detection
Alarm extension modulelistno transmission
Measuring value 1listno
Measuring value transmission formatlist16 bit EIS5
Measuring value for 0% of measuring signal (-32768...32767)signedInt -32768…327670
Base value 0% of measuring value (0...255)signedInt 0…2550
Measuring value for 100% of measuring signal (-32768...32767)signedInt -32768…32767100
Base value 100% of measuring value (0...255)signedInt 0…255255
Measuring range scaling factorlist* 0.01
Transmit measuring value in the event of a change bylist3%
Measuring value cycl. transm. factor (base 10s, 0 = no cycl. transmission)unsignedInt 0…1200
Measuring value 2listno
Measuring value for 100% of measuring signal (-32768...32767)signedInt -32768…327671000
Measuring value 3listno
Measuring value 4listno
Measuring value 5listno
Measuring value 6listno
Measuring value 7listno
Measuring value 8listno
Input 1listno
Limit value 1 (in % of measuring range)unsignedInt 0…10020
Limit value hysteresis 1unsignedInt 0…10010
Limit value (LV) activation 1listbelow LV = ON, above LV+hysteresis=OFF
External limit value LV 1listno
Format of ext. limit value obj. LV 1list16 bit EIS5
Limit value 1 cycl. transm. factor (base 10s, 0 = no cycl. transmission)unsignedInt 0…1200
Limit value 2 (in % of measuring range)unsignedInt 0…10080
Limit value hysteresis 2unsignedInt 0…10010
Limit value (LV) activation 2listabove LV = ON, below LV-hysteresis=OFF
External limit value LV 2listno
Format of ext. limit value obj. LV 2list16 bit EIS5
Limit value 2 cycl. transm. factor (base 10s, 0 = no cycl. transmission)unsignedInt 0…1200
Input 2listno
Input 3listno
Input 4listno
Input 5listno
Input 6listno
Input 7listno
Input 8listno

Version history

ApplicationApp noFingerprintFirst seenSizeFile
STYF784 0.1 latest$209FBB392026-11-25110 KBDownload

About this file

This is the official ETS product database for the Hager Electro 4-channel analog input (TYF784), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.