4-input module flush mounted TX304
Hager Electro · Order number TX304 · Inputs › 4-input modules embedded
TX304
Download .knxprod TL304A V2.0 2.0 · 74 KB
Product
| Manufacturer | Hager Electro |
|---|---|
| Product name | 4-input module flush mounted |
| Order number | TX304 |
| Product text | 4 entrées à encastrer |
| Hardware | TX304 4 entrées à encastrer |
| Medium | Twisted Pair |
| Rail mounted | No |
| Registration | Registered |
| Languages | fr-FR, de-DE, en-US |
| Catalog entry | M-0009_H-9.20.2F.2F.20TX304-1_HP-2003-20-F61B_CI-TX304-1 |
| Fingerprint | F61B |
| SHA-256 | adceccacba8a1d5ae34102ff9707c88b4e77de27e3e6f9838bdfefd47e09b5cb |
| First seen | 2026-11-25 |
| Markets | 69 markets |
Application program: TL304A V2.0 2.0
| Application number | $2003 |
|---|---|
| Version | 2.0 |
| Mask version | MV-0012 (1.2) |
| KNX Data Secure | No |
| Parameters | 103 |
| Group objects | 51 |
Group objects (51)
| No | Name | Function | Size | DPT | Flags |
|---|---|---|---|---|---|
| 0 | Indication d'état | Entrée 1 | 1 Bit | CRW | |
| 1 | Marche / Arrêt | Entrée 1 | 1 Bit | CRT | |
| 1 | Inclinaison | Entrée 1 | 1 Bit | CRT | |
| 1 | Alarme 2 | Entrée 1 | 1 Bit | CRT | |
| 1 | Alarme 1 | Entrée 1 | 1 Bit | CRT | |
| 1 | Minuterie | Entrée 1 | 1 Bit | CRT | |
| 1 | Non utilisé | Entrée 1 | 1 Bit | CRT | |
| 2 | Montée / Descente | Entrée 1 | 1 Bit | CRT | |
| 3 | Forçage | Entrée 1 | 2 Bit | CRT | |
| 4 | Variation | Entrée 1 | 4 Bit | CRT | |
| 5 | Sélection de consigne | Entrée 1 | 1 Byte | CRT | |
| 5 | Scène | Entrée 1 | 1 Byte | CRT | |
| 6 | Indication d'état | Entrée 2 | 1 Bit | CRW | |
| 7 | Marche / Arrêt | Entrée 2 | 1 Bit | CRT | |
| 7 | Non utilisé | Entrée 2 | 1 Bit | CRT | |
| 7 | Inclinaison | Entrée 2 | 1 Bit | CRT | |
| 7 | Minuterie | Entrée 2 | 1 Bit | CRT | |
| 7 | Alarme 1 | Entrée 2 | 1 Bit | CRT | |
| 7 | Alarme 2 | Entrée 2 | 1 Bit | CRT | |
| 8 | Montée / Descente | Entrée 2 | 1 Bit | CRT | |
| 9 | Forçage | Entrée 2 | 2 Bit | CRT | |
| 10 | Variation | Entrée 2 | 4 Bit | CRT | |
| 11 | Scène | Entrée 2 | 1 Byte | CRT | |
| 11 | Sélection de consigne | Entrée 2 | 1 Byte | CRT | |
| 12 | Indication d'état | Entrée 3 | 1 Bit | CRWT | |
| 12 | Indication d'état | Entrée 3 | 1 Bit | CRW | |
| 13 | Marche / Arrêt | Entrée 3 | 1 Bit | CRT | |
| 13 | Inclinaison | Entrée 3 | 1 Bit | CRT | |
| 13 | Alarme 2 | Entrée 3 | 1 Bit | CRT | |
| 13 | Alarme 1 | Entrée 3 | 1 Bit | CRT | |
| 13 | Minuterie | Entrée 3 | 1 Bit | CRT | |
| 13 | Non utilisé | Entrée 3 | 1 Bit | CRT | |
| 14 | Montée / Descente | Entrée 3 | 1 Bit | CRT | |
| 15 | Forçage | Entrée 3 | 2 Bit | CRT | |
| 16 | Variation | Entrée 3 | 4 Bit | CRT | |
| 17 | Sélection de consigne | Entrée 3 | 1 Byte | CRT | |
| 17 | Scène | Entrée 3 | 1 Byte | CRT | |
| 18 | Indication d'état | Entrée 4 | 1 Bit | CRW | |
| 19 | Marche / Arrêt | Entrée 4 | 1 Bit | CRT | |
| 19 | Inclinaison | Entrée 4 | 1 Bit | CRT | |
| 19 | Alarme 2 | Entrée 4 | 1 Bit | CRT | |
| 19 | Alarme 1 | Entrée 4 | 1 Bit | CRT | |
| 19 | Minuterie | Entrée 4 | 1 Bit | CRT | |
| 19 | Non utilisé | Entrée 4 | 1 Bit | CRT | |
| 20 | Montée / Descente | Entrée 4 | 1 Bit | CRT | |
| 21 | Forçage | Entrée 4 | 2 Bit | CRT | |
| 22 | Variation | Entrée 4 | 4 Bit | CRT | |
| 23 | Sélection de consigne | Entrée 4 | 1 Byte | CRT | |
| 23 | Scène | Entrée 4 | 1 Byte | CRT | |
| 24 | loc_state | configuration | 1 Bit | ||
| 25 | channel_activation | configuration | 1 Byte |
Parameters (18)
| Parameter | Type | Default |
|---|---|---|
| Entrée 1-4 | list | aucun |
| anti-rebond | list | 50ms |
| Durée appui long | list | 450ms |
| Période alarme intempérie | list | non utilisée |
| Entrée 1 | list | aucun |
| Type de canal | list | bouton poussoir |
| Front actif | list | front montant |
| Numéro de scène | list | scène 1 |
| sens de mouvement | list | montée |
| sens de variation | list | Variation plus |
| action sur front actif | list | Marche / Arrêt |
| Mode de forçage | list | Forçage marche |
| sélection de consigne | list | confort / économique |
| Entrée 2 | list | aucun |
| Entrée 3 | list | aucun |
| Entrée 4 | list | aucun |
| Version du logiciel d'application | text | 2.0.2 |
| CycleTime for Binary sensor (on/cyclic o ff) | unsignedInt 0…65535 | 240 |
Version history
| Application | App no | Fingerprint | First seen | Size | File |
|---|---|---|---|---|---|
| TL304A V2.0 2.0 latest | $2003 | F61B | 2026-11-25 | 74 KB | Download |
About this file
This is the official ETS product database for the Hager Electro 4-input module flush mounted (TX304), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.
More from Hager Electro
- RF unidir inputs concetrator white TR351A
- RF unidir inputs concetrator silver TR351B
- 2-input module flush mounted TX302
- 4-input module modular TX314
- 6-input module modular TX316
- 4-fold input 230V~ TXA304
- 6-fold input universal TXA306
- 10-fold input 230V AC TXA310
- 2-input modules embedded TXB302
- 4-input modules embedded TXB304
- Universal interface 8gang comfort TYB708D
- Flush mounted input device 2 -fold TYBS702A