Thermostat Control Panel TC0203
Guangzhou SeaWin Electrical Technologies Co., Ltd. · Order number TC0203 · Heating,ventilation,air conditioning › Panels
Download .knxprod Thermostat Control Panel 0.2 · 85 KB
Product
| Manufacturer | Guangzhou SeaWin Electrical Technologies Co., Ltd. |
|---|---|
| Product name | Thermostat Control Panel |
| Order number | TC0203 |
| Hardware | Thermostat Control Panel |
| Medium | Twisted Pair |
| Bus current (mA) | 12 |
| Rail mounted | No |
| Device kind | Accessory |
| Registration | Certified · 2022-02-23 |
| Languages | en-US |
| Catalog entry | M-014B_H-00014B060302-2_HP-0603-02-3AC1_CI-TC0203-1 |
| Fingerprint | 3AC1 |
| SHA-256 | 3fe4a6125b181eeb452a20a4f00d8e13ab77ced63a38e7ea8a14bf14c3fc61af |
| First seen | 2026-11-25 |
| Markets | 69 markets |
Application program: Thermostat Control Panel 0.2
| Application number | $0603 |
|---|---|
| Version | 0.2 |
| Mask version | MV-0705 (7.5) |
| KNX Data Secure | No |
| Minimum ETS version | 4.0 |
| Parameters | 215 |
| Group objects | 87 |
Group objects (87)
| No | Name | Function | Size | DPT | Flags |
|---|---|---|---|---|---|
| 0 | AC, Switch | On/Off-Output | 1 Bit | 1.1 switch | CRTU |
| 1 | AC, Feedback, switch | On/Off-Input | 1 Bit | 1.1 switch | CRWTU |
| 2 | AC, Operating mode | 8-bit Value-Output | 1 Byte | 20.105 HVAC control mode | CRTU |
| 3 | AC, Feedback,Operating mode | 8-bit Value-Input | 1 Byte | 20.105 HVAC control mode | CRWTU |
| 4 | AC, Fan speed | 8-bit Value-Output | 1 Byte | 5.1 percentage (0..100%) | CRTU |
| 5 | AC, Feedback, Status fan speed | 8-bit Value-Input | 1 Byte | 5.1 percentage (0..100%) | CRWTU |
| 6 | AC, Setting temperature | 16-bit Value-Output | 2 Bytes | 9.1 temperature (°C) | CRTU |
| 7 | AC, Feedback, Setting temperature | 16-bit Value-Input | 2 Bytes | 9.1 temperature (°C) | CRWTU |
| 8 | AC, Actual temperature | 16-bit Value-Input | 2 Bytes | 9.1 temperature (°C) | CRWTU |
| 11 | FCU, Cooling control | On/Off-Output | 1 Bit | 1.1 switch | CRTU |
| 12 | FCU, Cooling feedback | On/Off-Input | 1 Bit | 1.1 switch | CRWTU |
| 13 | FCU, Cooling control | Valve positon-Output | 1 Byte | 5.1 percentage (0..100%) | CRTU |
| 14 | FCU, Cooling feedback | Valve positon-Input | 1 Byte | 5.1 percentage (0..100%) | CRWTU |
| 15 | FCU, Heating control | On/Off-Output | 1 Bit | 1.1 switch | CRTU |
| 16 | FCU, Heating feedback | On/Off-Input | 1 Bit | 1.1 switch | CRWTU |
| 17 | FCU, Heating control | Valve positon-Output | 1 Byte | 5.1 percentage (0..100%) | CRTU |
| 18 | FCU, Heating feedback | Valve positon-Input | 1 Byte | 5.1 percentage (0..100%) | CRWTU |
| 19 | FCU, Fan speed 1 | On/Off-Output | 1 Bit | 1.1 switch | CRTU |
| 20 | FCU, Fan speed 2 | On/Off-Output | 1 Bit | 1.1 switch | CRTU |
| 21 | FCU, Fan speed 3 | On/Off-Output | 1 Bit | 1.1 switch | CRTU |
| 22 | FCU, Statu fan speed 1 | On/Off-Input | 1 Bit | 1.1 switch | CRWTU |
| 23 | FCU, Statu fan speed 2 | On/Off-Input | 1 Bit | 1.1 switch | CRWTU |
| 24 | FCU, Statu fan speed 3 | On/Off-Input | 1 Bit | 1.1 switch | CRWTU |
| 25 | FCU, Fan speed | 8-bit Value-Output | 1 Byte | 5.1 percentage (0..100%) | CRTU |
| 26 | FCU, Status fan speed | 8-bit Value-Input | 1 Byte | 5.1 percentage (0..100%) | CRWTU |
| 27 | FCU, Actual temperature | 16-bit Value-Input | 2 Bytes | 9.1 temperature (°C) | CRWTU |
| 28 | FCU, Recv setting mode | 8-bit Value-Input | 1 Byte | 20.105 HVAC control mode | CRWTU |
| 29 | FCU, Send setting mode | 8-bit Value-Output | 1 Byte | 20.105 HVAC control mode | CRTU |
| 30 | FCU, Recv setting speed | 8-bit Value-Input | 1 Byte | 5.1 percentage (0..100%) | CRWTU |
| 31 | FCU, Send setting speed | 8-bit Value-Output | 1 Byte | 5.1 percentage (0..100%) | CRTU |
| 32 | FCU, Recv setting temperature | 16-bit Value-Input | 2 Bytes | 9.1 temperature (°C) | CRWTU |
| 33 | FCU, Send setting temperature | 16-bit Value-Output | 2 Bytes | 9.1 temperature (°C) | CRTU |
| 34 | FCU, Recv setting switch | On/Off-Input | 1 Bit | 1.1 switch | CRWTU |
| 35 | FCU, Send setting switch | On/Off-Output | 1 Bit | 1.1 switch | CRTU |
| 36 | FH, Relay switch | On/Off-Output | 1 Bit | 1.1 switch | CRTU |
| 37 | FH, Status relay switch | On/Off-Input | 1 Bit | 1.1 switch | CRWTU |
| 38 | FH, Actual temperature | 16-bit Value-Input | 2 Bytes | 9.1 temperature (°C) | CRWTU |
| 41 | FH, Recv setting temperature | 16-bit Value-Input | 2 Bytes | 9.1 temperature (°C) | CRWTU |
| 42 | FH, Send setting temperature | 16-bit Value-Output | 2 Bytes | 9.1 temperature (°C) | CRTU |
| 43 | FH, Recv setting switch | On/Off-Input | 1 Bit | 1.1 switch | CRWTU |
| 44 | FH, Send setting switch | On/Off-Output | 1 Bit | 1.1 switch | CRTU |
| 51 | FH, High temperature alarm | On/Off-Output | 1 Bit | 1.1 switch | CRTU |
| 52 | FA, Air inlet speed 1 | On/Off-Output | 1 Bit | 1.1 switch | CRTU |
| 53 | FA, Air inlet speed 2 | On/Off-Output | 1 Bit | 1.1 switch | CRTU |
| 54 | FA, Air inlet speed 3 | On/Off-Output | 1 Bit | 1.1 switch | CRTU |
| 55 | FA, Status air inlet speed 1 | On/Off-Input | 1 Bit | 1.1 switch | CRWTU |
| 56 | FA, Status air inlet speed 2 | On/Off-Input | 1 Bit | 1.1 switch | CRWTU |
| 57 | FA, Status air inlet speed 3 | On/Off-Input | 1 Bit | 1.1 switch | CRWTU |
| 58 | FA, Air inlet speed | 8-bit Value-Output | 1 Byte | 5.1 percentage (0..100%) | CRTU |
| 59 | FA, Status air inlet speed | 8-bit Value-Input | 1 Byte | 5.1 percentage (0..100%) | CRWTU |
| 60 | FA, Air outlet speed 1 | On/Off-Output | 1 Bit | 1.1 switch | CRTU |
| 61 | FA, Air outlet speed 2 | On/Off-Output | 1 Bit | 1.1 switch | CRTU |
| 62 | FA, Air outlet speed 3 | On/Off-Output | 1 Bit | 1.1 switch | CRTU |
| 63 | FA, Status air outlet speed 1 | On/Off-Input | 1 Bit | 1.1 switch | CRWTU |
| 64 | FA, Status air outlet speed 2 | On/Off-Input | 1 Bit | 1.1 switch | CRWTU |
| 65 | FA, Status air outlet speed 3 | On/Off-Input | 1 Bit | 1.1 switch | CRWTU |
| 66 | FA, Air outlet speed | 8-bit Value-Output | 1 Byte | 5.1 percentage (0..100%) | CRTU |
| 67 | FA, Status air outlet speed | 8-bit Value-Input | 1 Byte | 5.1 percentage (0..100%) | CRWTU |
| 70 | FA, Recv setting inlet speed | 8-bit Value-Input | 1 Byte | 5.1 percentage (0..100%) | CRWTU |
| 71 | FA, Send setting inlet speed | 8-bit Value-Output | 1 Byte | 5.1 percentage (0..100%) | CRTU |
| 72 | FA, Recv setting outlet speed | 8-bit Value-Input | 1 Byte | 5.1 percentage (0..100%) | CRWTU |
| 73 | FA, Send setting outlet speed | 8-bit Value-Output | 1 Byte | 5.1 percentage (0..100%) | CRTU |
| 74 | FA, Recv setting switch | On/Off-Input | 1 Bit | 1.1 switch | CRWTU |
| 75 | FA, Send setting switch | On/Off-Output | 1 Bit | 1.1 switch | CRTU |
| 76 | Pub, Recv main switch | On/Off-Input | 1 Bit | 1.1 switch | CRWTU |
| 77 | Pub, Status main switch | On/Off-Output | 1 Bit | 1.1 switch | CRTU |
| 78 | Pub, Switch temperature unit | 1-bit Value-Input | 1 Bit | 1.1 switch | CRWTU |
| 79 | Pub, Status temperature unit | 1-bit Value-Output | 1 Bit | 1.1 switch | CRTU |
| 80 | Pub, Child lock | 1-bit Value-Input | 1 Bit | 1.1 switch | CRWTU |
| 81 | Pub, Status child lock | 1-bit Value-Output | 1 Bit | 1.1 switch | CRTU |
| 82 | Pub, Recv actual temperature | 16-bit Value-Input | 2 Bytes | 9.1 temperature (°C) | CRWTU |
| 83 | Pub, Send actual temperature | 16-bit Value-Output | 2 Bytes | 9.1 temperature (°C) | CRTU |
| 84 | Pub, Recv actual humidity | 16-bit Value-Input | 2 Bytes | 9.7 humidity (%) | CRWTU |
| 85 | Pub, Send actual humidity | 16-bit Value-Output | 2 Bytes | 9.7 humidity (%) | CRTU |
| 86 | Pub, Recv actual PM2.5 | 16-bit Value-Input | 2 Bytes | CRWTU | |
| 87 | Pub, Recv actual PM1.0 | 16-bit Value-Input | 2 Bytes | CRWTU | |
| 88 | Pub, Recv actual HCHO | 16-bit Value-Input | 2 Bytes | CRWTU | |
| 89 | Pub, Recv actual TVOC | 16-bit Value-Input | 2 Bytes | CRWTU | |
| 90 | Pub, Recv actual CO | 16-bit Value-Input | 2 Bytes | 9.8 parts/million (ppm) | CRWTU |
| 91 | Pub, Recv actual CO2 | 16-bit Value-Input | 2 Bytes | 9.8 parts/million (ppm) | CRWTU |
| 92 | Overwrite brightness, Backlight | 8-bit Value | 1 Byte | 5.1 percentage (0..100%) | CRWTU |
| 93 | Overwrite brightness, Waking backlight | 8-bit Value | 1 Byte | 5.1 percentage (0..100%) | CRWTU |
| 94 | Overwrite brightness, Sleeping backlight | 8-bit Value | 1 Byte | 5.1 percentage (0..100%) | CRWTU |
| 95 | Input from master, Control own backlight | On / Off | 1 Bit | 1.1 switch | CRWTU |
| 96 | Master output, Control other's backlight | On / Off | 1 Bit | 1.1 switch | CRWTU |
| 97 | Input-triggering, Waking backlight | On / Off | 1 Bit | 1.1 switch | CRWTU |
| 98 | Triggering output, Waking backlight | On / Off | 1 Bit | 1.1 switch | CRWTU |
Parameters (191)
| Parameter | Type | Default |
|---|---|---|
| Air conditioning func select | list | Disabled |
| Switching func. | list | Disabled |
| Switching polarity | list | 0:Off, 1:On |
| Feedback Polarity | list | 0:Off, 1:On |
| Operating mode | list | Disabled |
| Fan speed | list | Disabled |
| Setting temperature | list | Disabled |
| Heating value | unsignedInt 0…255 | 1 |
| Cooling value | unsignedInt 0…255 | 3 |
| Venting value | unsignedInt 0…255 | 9 |
| Drying value | unsignedInt 0…255 | 14 |
| Automatic value | unsignedInt 0…255 | 0 |
| Heating value for feedback | unsignedInt 0…255 | 1 |
| Cooling value for feedback | unsignedInt 0…255 | 3 |
| Venting value for feedback | unsignedInt 0…255 | 9 |
| Drying value for feedback | unsignedInt 0…255 | 14 |
| Automatic value for feedback | unsignedInt 0…255 | 0 |
| Fan speed level | list | Level 3 |
| Low speed value | unsignedInt 0…255 | 1 |
| High speed value | unsignedInt 0…255 | 2 |
| Low speed value for feedback | unsignedInt 0…255 | 1 |
| High speed value for feedback | unsignedInt 0…255 | 2 |
| Middle speed value | unsignedInt 0…255 | 2 |
| High speed value | unsignedInt 0…255 | 3 |
| Middle speed value for feedback | unsignedInt 0…255 | 2 |
| High speed value for feedback | unsignedInt 0…255 | 3 |
| Value for speed level 1 | unsignedInt 0…255 | 1 |
| Value for speed level 2 | unsignedInt 0…255 | 2 |
| Value for speed level 3 | unsignedInt 0…255 | 3 |
| Value for speed level 4 | unsignedInt 0…255 | 4 |
| Value for speed level 5 | unsignedInt 0…255 | 5 |
| Value feedback for speed level 1 | unsignedInt 0…255 | 1 |
| Value feedback for speed level 2 | unsignedInt 0…255 | 2 |
| Value feedback for speed level 3 | unsignedInt 0…255 | 3 |
| Value feedback for speed level 4 | unsignedInt 0…255 | 4 |
| Value feedback for speed level 5 | unsignedInt 0…255 | 5 |
| Cooling control | list | Disabled |
| Cooling object type | list | 1 bit |
| Cooling control feedback | list | Disabled |
| Heating control | list | Disabled |
| Heating object type | list | 1 bit |
| Heating control feedback | list | Disabled |
| Fan speed control | list | Disabled |
| Fan speed feedback | list | Disabled |
| Value for fan speed 1 | unsignedInt 0…255 | 1 |
| Value for fan speed 2 | unsignedInt 0…255 | 2 |
| Value for fan speed 3 | unsignedInt 0…255 | 3 |
| Value for fan speed Off | unsignedInt 0…255 | 0 |
| Value feedback for fan speed 1 | unsignedInt 0…255 | 1 |
| Value feedback for fan speed 2 | unsignedInt 0…255 | 2 |
| Value feedback for fan speed 3 | unsignedInt 0…255 | 3 |
| Value feedback for fan speed Off | unsignedInt 0…255 | 0 |
| Source for actual temperature | list | internal value |
| Recv setting mode | list | Disabled |
| Send setting mode | list | Disabled |
| Recv setting fan speed | list | Disabled |
| Send setting fan speed | list | Disabled |
| Recv setting temperature | list | Disabled |
| Send setting temperature | list | Disabled |
| Recv setting FCU switch | list | Disabled |
| Send setting FCU switch | list | Disabled |
| Floor heating | list | Disabled |
| Relay switch | list | Disabled |
| Status relay switch | list | Disabled |
| Recv setting function switch | list | Disabled |
| Send setting function switch | list | Disabled |
| Status high temperature alarm | list | Disabled |
| Trigger temperature(degrees) | unsignedInt 5…45 | 35 |
| Cycle time for high temperature alarm | list | 10 seconds |
| Ventilation system | list | Disabled |
| Fan speed control for air inlet | list | Disabled |
| Fan inlet speed feedback | list | Disabled |
| Value for fan inlet speed 1 | unsignedInt 0…255 | 1 |
| Value for fan inlet speed 2 | unsignedInt 0…255 | 2 |
| Value for fan inlet speed 3 | unsignedInt 0…255 | 3 |
| Value for fan inlet speed Off | unsignedInt 0…255 | 0 |
| Value feedback for fan inlet speed 1 | unsignedInt 0…255 | 1 |
| Value feedback for fan inlet speed 2 | unsignedInt 0…255 | 2 |
| Value feedback for fan inlet speed 3 | unsignedInt 0…255 | 3 |
| Value feedback for fan inlet speed Off | unsignedInt 0…255 | 0 |
| Fan speed control for air outlet | list | Disabled |
| Fan outlet speed feedback | list | Disabled |
| Value for fan outlet speed 1 | unsignedInt 0…255 | 1 |
| Value for fan outlet speed 2 | unsignedInt 0…255 | 2 |
| Value for fan outlet speed 3 | unsignedInt 0…255 | 3 |
| Value for fan outlet speed Off | unsignedInt 0…255 | 0 |
| Value feedback for fan outlet speed 1 | unsignedInt 0…255 | 1 |
| Value feedback for fan outlet speed 2 | unsignedInt 0…255 | 2 |
| Value feedback for fan outlet speed 3 | unsignedInt 0…255 | 3 |
| Value feedback for fan outlet speed Off | unsignedInt 0…255 | 0 |
| Recv setting fan inlet speed | list | Disabled |
| Send setting fan inlet speed | list | Disabled |
| Recv setting fan outlet speed | list | Disabled |
| Send setting fan outlet speed | list | Disabled |
| Public function | list | Disabled |
| Recv setting main switch | list | Disabled |
| Send setting main switch | list | Disabled |
| Toggle temperature unit | list | Disabled |
| Temperature unit polarity | list | 0:Centigrade, 1:Fahrenheit |
| Send toggle temperature unit | list | Disabled |
| child lock control | list | Disabled |
| Initial value for child lock | list | unlocking |
| Send child lock control | list | Disabled |
| Actual temperature | list | Disabled |
| Send actual temperature | list | Disabled |
| The mode for sending value | list | transmit value in cycles |
| The time in cycles | list | 10 seconds |
| Send actual temperature on change | list | 1 degrees |
| Actual humidity | list | Disabled |
| Send actual humidity | list | Disabled |
| Send actual humidity on change | list | 2 % |
| Recv actual PM2.5 | list | Disabled |
| Recv actual PM1.0 | list | Disabled |
| Recv actual HCHO | list | Disabled |
| Recv actual TVOC | list | Disabled |
| Recv actual CO | list | Disabled |
| Recv actual CO2 | list | Disabled |
| Send value for triggering alarm | list | Off |
| Read feedback object at voltage recovery | list | No |
| Option for setting | list | Disabled |
| Venting mode | list | Disabled |
| Drying mode | list | Disabled |
| Automatic mode | list | Disabled |
| Backlight settings | list | Disabled |
| Backlight mode | list | always |
| Backlight Brightness | list | 100% |
| Overwrite backlight brightness via object | list | No |
| Backlight brightness when waking up | list | 100% |
| Delay time after waking backlight | list | 5 seconds |
| Backlight brightness when sleeping | list | 0% |
| Overwrite waking backlight via object | list | No |
| Overwrite sleeping backlight via object | list | No |
| Master output for controlling other's backlight | list | No |
| Temperature unit | list | Celsius |
| Child lock polarity | list | 0:Unlock 1:Lock |
| Temperature correction for internal | list | 0 degree |
| Temperature correction for knx bus | list | 0 degree |
| Source for actual humidity | list | internal value |
| Internal temperature probe | list | Temperature probe 1 |
| Temperature hysteresis[0..30]*0.1°C | unsignedInt 0…30 | 5 |
| Advanced correction for internal temperature | list | Disabled |
| Device temperature A[*0.1] °C | signedInt -200…800 | 0 |
| Standard temperature A[*0.1] °C | signedInt -200…800 | 0 |
| Device temperature B[*0.1] °C | signedInt -200…800 | 0 |
| Standard temperature B[*0.1] °C | signedInt -200…800 | 0 |
| Key LED mode | list | Associated backlight delay |
| [Y][02] Knob aperture mode | list | Associated backlight delay |
| Color of knob aperture | list | Default configuration |
| R value of the aperture for cool mode | unsignedInt 0…255 | 0 |
| G value of the aperture for cool mode | unsignedInt 0…255 | 0 |
| B value of the aperture for cool mode | unsignedInt 0…255 | 0 |
| R value of the aperture for heat mode | unsignedInt 0…255 | 0 |
| G value of the aperture for heat mode | unsignedInt 0…255 | 0 |
| B value of the aperture for heat mode | unsignedInt 0…255 | 0 |
| R value of the aperture for dry mode | unsignedInt 0…255 | 0 |
| G value of the aperture for dry mode | unsignedInt 0…255 | 0 |
| B value of the aperture for dry mode | unsignedInt 0…255 | 0 |
| R value of the aperture for ventilate mode | unsignedInt 0…255 | 0 |
| G value of the aperture for ventilate mode | unsignedInt 0…255 | 0 |
| B value of the aperture for ventilate mode | unsignedInt 0…255 | 0 |
| R value of the aperture for auto mode | unsignedInt 0…255 | 0 |
| G value of the aperture for auto mode | unsignedInt 0…255 | 0 |
| B value of the aperture for auto mode | unsignedInt 0…255 | 0 |
| R value of the aperture for floor heating | unsignedInt 0…255 | 0 |
| G value of the aperture for floor heating | unsignedInt 0…255 | 0 |
| B value of the aperture for floor heating | unsignedInt 0…255 | 0 |
| R value of the aperture for fresh air | unsignedInt 0…255 | 0 |
| G value of the aperture for fresh air | unsignedInt 0…255 | 0 |
| B value of the aperture for fresh air | unsignedInt 0…255 | 0 |
| R value of the aperture for air data | unsignedInt 0…255 | 0 |
| G value of the aperture for air data | unsignedInt 0…255 | 0 |
| B value of the aperture for air data | unsignedInt 0…255 | 0 |
| Radar or proximity sensing | list | Disabled |
| Cooling mode | list | Disabled |
| Heating mode | list | Disabled |
| Value for setting heating | unsignedInt 0…255 | 1 |
| Value for setting cooling | unsignedInt 0…255 | 3 |
| Value for setting fan only | unsignedInt 0…255 | 9 |
| Heating mode | list | Enabled |
| Value for setting fan speed low | unsignedInt 0…255 | 1 |
| Value for setting fan speed mid | unsignedInt 0…255 | 2 |
| Value for setting fan speed high | unsignedInt 0…255 | 3 |
| Value for setting fan speed off | unsignedInt 0…255 | 0 |
| Value for setting fan speed auto | unsignedInt 0…255 | 4 |
| Cooling mode | list | Enabled |
| Venting mode | list | Enabled |
| Time to detect sensor circularly for output | list | only once when triggered |
| Wake up backlight via object | list | No |
| The triggering value for waking backlight | list | On is triggering value |
| Output triggering signal for waking backlight | list | No |
| The triggering value for output | list | On is triggering value |
Version history
| Application | App no | Fingerprint | First seen | Size | File |
|---|---|---|---|---|---|
| Thermostat Control Panel 0.2 latest | $0603 | 3AC1 | 2026-11-25 | 85 KB | Download |
About this file
This is the official ETS product database for the Guangzhou SeaWin Electrical Technologies Co., Ltd. Thermostat Control Panel (TC0203), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.
More from Guangzhou SeaWin Electrical Technologies Co., Ltd.
- Thermostat Control Panel TC0103
- Thermostat Control Panel TC0303
- Thermostat Control Panel TC0403
- Thermostat Control Panel TC0503
- Panel Interface,ESM0406 ESM0406
- Dimming Actuator, 1-fold, 16A MD011602
- Dimming Actuator, 2-fold, 10A MD021002
- Dimming Actuator, 4-fold, 3A MD040302
- Dimming Actuator, 4-fold, 5A MD040502
- Dimming Actuator, 4-fold, 16A MD041601
- 1-10V,Dimming Actuator,4-fold MD042003
- Dimming Actuator, 6-fold, 16A MD061601
All Guangzhou SeaWin Electrical Technologies Co., Ltd. products