KNX Database

I-Luxus Room Controller / Push Button PBI/PTI-000x

Goldmedal · Order number PBI/PTI-000x · Heating,Ventilation,Air Conditioning › Thermostat

Download .knxprod I-Luxus Thermostat 0.4 · 936 KB

Product

ManufacturerGoldmedal
Product nameI-Luxus Room Controller / Push Button
Order numberPBI/PTI-000x
Product textRoom Controller / Push Button
HardwareHw_RoomController_PushButton
MediumTwisted Pair
Bus current (mA)15
Rail mountedNo
RegistrationCertified · 2025-07-23
Languagesen-US
Catalog entryM-0270_H-PBI.2FPTI.2D000x-4-O01E7_HP-0001-04-64E9-O01E7_CI-PBI.2FPTI.2D000x-1
Fingerprint64E9
SHA-2560f675a7f15a1efad496f535e9bf141bfcfd84d3315ace434bb8eac1f86ba0048
First seen2026-11-25
MarketsGermany, India

Application program: App_RoomController_PushButton 0.4

Application number$0001
Version0.4
Mask versionMV-07B0 (System B)
KNX Data SecureNo
Minimum ETS version5.0
Parameters2518
Group objects1656
Group objects (1656)
NoNameFunctionSizeDPTFlags
1Actual Internal & External TemperatureTemperature Value2 Bytes9.1 temperature (°C)CRT
1Button 1 Short PressTemperature Value2 Bytes9.1 temperature (°C)CRT
1Button 1 Short PressSwitching 2Bit2 Bit2.1 switch controlCRT
1Button 1 Short PressSwitching 1Byte Value1 Byte5.10 counter pulses (0..255)CRT
1Button 1 Short PressSwitching Percent Value1 Byte5.1 percentage (0..100%)CRT
1Button 1 Short PressSwitching 2Byte Value2 Bytes7.1 pulsesCRT
1Button 1 DimmingSwitch On Off1 Bit1.1 switchCRT
1Button 1 Blind/ShutterUp/Down1 Bit1.8 up/downCRT
1Button 1 SceneScene Control1 Byte18.1 scene controlCRT
1Button 1 Multiple OperationFold 11 Bit1.1 switchCRT
1Button 1 CounterRequest Value1 Bit1.17 triggerCW
1Button 1 Multiple OperationFold 12 Bit2.1 switch controlCRT
1Button 1 Short PressSwitching 1Bit1 Bit1.1 switchCRT
1Button 1 Multiple OperationFold 11 Byte5.10 counter pulses (0..255)CRT
1Button 1 Multiple OperationFold 12 Bytes7.1 pulsesCRT
1Button 1 Multiple OperationFold 12 Bytes9.1 temperature (°C)CRT
1Button 1 Multiple OperationFold 12 Bytes9.4 lux (Lux)CRT
1Button 1 Sequence FunctionFold 11 Byte5.10 counter pulses (0..255)CRT
1Button 1 Sequence FunctionFold 11 Bit1.1 switchCRT
1Button 1 Sequence FunctionFold 12 Bytes7.1 pulsesCRT
1Button 1 Sequence FunctionFold 12 Bytes9.4 lux (Lux)CRT
1Button 1 Sequence FunctionFold 12 Bit2.1 switch controlCRT
1Button 1 Sequence FunctionFold 11 Byte5.1 percentage (0..100%)CRT
1Button 1 Sequence FunctionFold 12 Bytes9.1 temperature (°C)CRT
1Button 1 Multiple OperationFold 11 Byte5.1 percentage (0..100%)CRT
1Button 1 Short PressLux Value2 Bytes9.4 lux (Lux)CRT
1Button 1 Fan ControlFan Control1 Byte5.10 counter pulses (0..255)CRT
1Button 1 Fan ControlFan Control1 Byte5.1 percentage (0..100%)CRT
1Button 1 Operating ModeOperating Mode1 Byte20.102 HVAC modeCRT
1Button 1 Operating ModeComfort1 Bit1.2 booleanCRT
1Button 1 Operating ModeStandby1 Bit1.2 booleanCRT
1Button 1 Operating ModeNight1 Bit1.2 booleanCRT
1Button 1 Operating ModeProtection1 Bit1.2 booleanCRT
1Button 1 Heat/CoolHeat/Cool1 Bit1.100 cooling/heatingCRT
1Button 1 Step Control1 Byte Percentage1 Byte5.1 percentage (0..100%)CRT
1Button 1 Step Control1 Byte Value1 Byte5.10 counter pulses (0..255)CRT
1Button 1 Step Control2 Byte Value2 Bytes7.1 pulsesCRT
1Button 1 Step ControlTemperature Value2 Bytes9.1 temperature (°C)CRT
1Button 1 Step ControlScene Value1 Byte18.1 scene controlCRT
1Button 1 Step ControlLux Value2 Bytes9.4 lux (Lux)CRT
1Button 1 External SetpointTemperature2 Bytes9.1 temperature (°C)CRT
1Button 1 HVAC ModeHVAC Mode1 Byte20.105 HVAC control modeCRT
2Button 1 Short Press StatusStatus1 Bit1.1 switchCRW
2Button 1 DimmingStatus1 Bit1.1 switchCRW
3Button 1 Long PressSwitching 2Byte Value2 Bytes7.1 pulsesCRT
3Button 1 Long PressLux Value2 Bytes9.4 lux (Lux)CRT
3Button 1 Long PressSwitching 1Byte Value1 Byte5.10 counter pulses (0..255)CRT
3Button 1 Long PressSwitching Percent Value1 Byte5.1 percentage (0..100%)CRT
3Button 1 Multiple OperationFold 22 Bytes7.1 pulsesCRT
3Button 1 Multiple OperationFold 22 Bit2.1 switch controlCRT
3Button 1 DimmingRelative Dimming4 Bit3.7 dimming controlCRT
3Button 1 Blind/ShutterStep/Stop1 Bit1.7 stepCRT
3Button 1 Multiple OperationFold 22 Bytes9.4 lux (Lux)CRT
3Button 1 Multiple OperationFold 21 Byte5.10 counter pulses (0..255)CRT
3Button 1 Multiple OperationFold 21 Bit1.1 switchCRT
3Button 1 Counter AlarmAlarm1 Bit1.5 alarmCRT
3Button 1 Multiple OperationFold 21 Byte5.1 percentage (0..100%)CRT
3Button 1 Sequence FunctionFold 22 Bit2.1 switch controlCRT
3Button 1 Sequence FunctionFold 21 Byte5.10 counter pulses (0..255)CRT
3Button 1 Sequence FunctionFold 21 Byte5.1 percentage (0..100%)CRT
3Button 1 Sequence FunctionFold 22 Bytes7.1 pulsesCRT
3Button 1 Sequence FunctionFold 22 Bytes9.1 temperature (°C)CRT
3Button 1 Sequence FunctionFold 22 Bytes9.4 lux (Lux)CRT
3Button 1 Sequence FunctionFold 21 Bit1.1 switchCRT
3Button 1 Long PressTemperature Value2 Bytes9.1 temperature (°C)CRT
3Button 1 Multiple OperationFold 22 Bytes9.1 temperature (°C)CRT
3Button 1 Long PressSwitching 1Bit1 Bit1.1 switchCRT
3Button 1 Long PressSwitching 2Bit2 Bit2.1 switch controlCRT
4Button 1 Long Press StatusStatus1 Bit1.1 switchCRW
5Button 1 Second ObjectSwitching Percent Value1 Byte5.1 percentage (0..100%)CRT
5Button 1 Multiple OperationFold 32 Bytes9.4 lux (Lux)CRT
5Button 1 Counter2Byte Value2 Bytes7.1 pulsesCRWT
5Button 1 Multiple OperationFold 31 Bit1.1 switchCRT
5Button 1 Multiple OperationFold 32 Bit2.1 switch controlCRT
5Button 1 Second ObjectSwitching 1Byte Value1 Byte5.10 counter pulses (0..255)CRT
5Button 1 Multiple OperationFold 31 Byte5.10 counter pulses (0..255)CRT
5Button 1 Multiple OperationFold 32 Bytes9.1 temperature (°C)CRT
5Button 1 Multiple OperationFold 31 Byte5.1 percentage (0..100%)CRT
5Button 1 Second ObjectSwitching 2Byte Value2 Bytes7.1 pulsesCRT
5Button 1 Second ObjectSwitching 2Bit2 Bit2.1 switch controlCRT
5Button 1 Sequence FunctionFold 32 Bytes9.4 lux (Lux)CRT
5Button 1 Second ObjectLux Value2 Bytes9.4 lux (Lux)CRT
5Button 1 Second ObjectTemperature Value2 Bytes9.1 temperature (°C)CRT
5Button 1 Sequence FunctionFold 32 Bytes9.1 temperature (°C)CRT
5Button 1 Sequence FunctionFold 31 Byte5.1 percentage (0..100%)CRT
5Button 1 Sequence FunctionFold 31 Byte5.10 counter pulses (0..255)CRT
5Button 1 Sequence FunctionFold 32 Bit2.1 switch controlCRT
5Button 1 Sequence FunctionFold 31 Bit1.1 switchCRT
5Button 1 Second ObjectSwitching 1Bit1 Bit1.1 switchCRT
5Button 1 Sequence FunctionFold 32 Bytes7.1 pulsesCRT
5Button 1 Multiple OperationFold 32 Bytes7.1 pulsesCRT
6Button 1 Second Object StatusStatus1 Bit1.1 switchCRW
6Button 1 Counter1Byte Value1 Byte5.10 counter pulses (0..255)CRWT
7Button 1 Multiple OperationFold 42 Bytes9.4 lux (Lux)CRT
7Button 1 Sequence FunctionFold 42 Bit2.1 switch controlCRT
7Button 1 Sequence FunctionFold 42 Bytes9.4 lux (Lux)CRT
7Button 1 Sequence FunctionFold 42 Bytes9.1 temperature (°C)CRT
7Button 1 Multiple OperationFold 42 Bytes9.1 temperature (°C)CRT
7Button 1 Sequence FunctionFold 41 Byte5.1 percentage (0..100%)CRT
7Button 1 Sequence FunctionFold 41 Byte5.10 counter pulses (0..255)CRT
7Button 1 Multiple OperationFold 42 Bytes7.1 pulsesCRT
7Button 1 Sequence FunctionFold 42 Bytes7.1 pulsesCRT
7Button 1 Sequence FunctionFold 41 Bit1.1 switchCRT
7Button 1 Counter4Byte Value4 Bytes12.1 counter pulses (unsigned)CRWT
7Button 1 Multiple OperationFold 41 Bit1.1 switchCRT
7Button 1 Multiple OperationFold 41 Byte5.1 percentage (0..100%)CRT
7Button 1 Multiple OperationFold 41 Byte5.10 counter pulses (0..255)CRT
7Button 1 Multiple OperationFold 42 Bit2.1 switch controlCRT
8Button 1 LockLock1 Bit1.3 enableCRW
9Button 1 LED statusStatus1 Bit1.1 switchCRW
12Button 1 Step CountLux Value2 Bytes9.4 lux (Lux)CRWTU
13Button 2 Short PressSwitching 1Bit1 Bit1.1 switchCRT
13Button 2 Short PressSwitching 2Bit2 Bit2.1 switch controlCRT
13Button 2 Short PressSwitching 1Byte Value1 Byte5.10 counter pulses (0..255)CRT
13Button 2 Short PressSwitching Percent Value1 Byte5.1 percentage (0..100%)CRT
13Button 2 Short PressSwitching 2Byte Value2 Bytes7.1 pulsesCRT
13Button 2 Short PressTemperature Value2 Bytes9.1 temperature (°C)CRT
13Button 2 Short PressLux Value2 Bytes9.4 lux (Lux)CRT
13Button 2 DimmingSwitch On Off1 Bit1.1 switchCRT
13Button 2 Blind/ShutterUp/Down1 Bit1.8 up/downCRT
13Button 2 SceneScene Control1 Byte18.1 scene controlCRT
13Button 2 Multiple OperationFold 11 Bit1.1 switchCRT
13Button 2 Multiple OperationFold 12 Bit2.1 switch controlCRT
13Button 2 Multiple OperationFold 11 Byte5.10 counter pulses (0..255)CRT
13Button 2 Multiple OperationFold 11 Byte5.1 percentage (0..100%)CRT
13Button 2 Multiple OperationFold 12 Bytes7.1 pulsesCRT
13Button 2 Multiple OperationFold 12 Bytes9.1 temperature (°C)CRT
13Button 2 Multiple OperationFold 12 Bytes9.4 lux (Lux)CRT
13Button 2 Sequence FunctionFold 11 Bit1.1 switchCRT
13Button 2 Sequence FunctionFold 12 Bit2.1 switch controlCRT
13Button 2 Sequence FunctionFold 11 Byte5.10 counter pulses (0..255)CRT
13Button 2 Sequence FunctionFold 11 Byte5.1 percentage (0..100%)CRT
13Button 2 Sequence FunctionFold 12 Bytes7.1 pulsesCRT
13Button 2 Sequence FunctionFold 12 Bytes9.1 temperature (°C)CRT
13Button 2 Sequence FunctionFold 12 Bytes9.4 lux (Lux)CRT
13Button 2 CounterRequest Value1 Bit1.17 triggerCW
13Button 2 Fan ControlFan Control1 Byte5.10 counter pulses (0..255)CRT
13Button 2 Fan ControlFan Control1 Byte5.1 percentage (0..100%)CRT
13Button 2 Operating ModeOperating Mode1 Byte20.102 HVAC modeCRT
13Button 2 Heat/CoolHeat/Cool1 Bit1.100 cooling/heatingCRT
13Button 2 Step Control1 Byte Value1 Byte5.10 counter pulses (0..255)CRT
13Button 2 Step Control1 Byte Percentage1 Byte5.1 percentage (0..100%)CRT
13Button 2 Step Control2 Byte Value2 Bytes7.1 pulsesCRT
13Button 2 Step ControlTemperature Value2 Bytes9.1 temperature (°C)CRT
13Button 2 Step ControlScene Value1 Byte18.1 scene controlCRT
13Button 2 Step ControlLux Value2 Bytes9.4 lux (Lux)CRT
13Button 2 External SetpointTemperature2 Bytes9.1 temperature (°C)CRT
13Button 2 HVAC ModeHVAC Mode1 Byte20.105 HVAC control modeCRT
14Button 2 Short Press StatusStatus1 Bit1.1 switchCRW
14Button 2 DimmingStatus1 Bit1.1 switchCRW
15Button 2 Long PressSwitching 1Bit1 Bit1.1 switchCRT
15Button 2 Long PressSwitching 2Bit2 Bit2.1 switch controlCRT
15Button 2 Long PressSwitching 1Byte Value1 Byte5.10 counter pulses (0..255)CRT
15Button 2 Long PressSwitching Percent Value1 Byte5.1 percentage (0..100%)CRT
15Button 2 Long PressSwitching 2Byte Value2 Bytes7.1 pulsesCRT
15Button 2 Long PressTemperature Value2 Bytes9.1 temperature (°C)CRT
15Button 2 Long PressLux Value2 Bytes9.4 lux (Lux)CRT
15Button 2 DimmingRelative Dimming4 Bit3.7 dimming controlCRT
15Button 2 Blind/ShutterStep/Stop1 Bit1.7 stepCRT
15Button 2 Multiple OperationFold 21 Bit1.1 switchCRT
15Button 2 Multiple OperationFold 22 Bit2.1 switch controlCRT
15Button 2 Multiple OperationFold 21 Byte5.10 counter pulses (0..255)CRT
15Button 2 Multiple OperationFold 21 Byte5.1 percentage (0..100%)CRT
15Button 2 Multiple OperationFold 22 Bytes7.1 pulsesCRT
15Button 2 Multiple OperationFold 22 Bytes9.1 temperature (°C)CRT
15Button 2 Multiple OperationFold 22 Bytes9.4 lux (Lux)CRT
15Button 2 Sequence FunctionFold 21 Bit1.1 switchCRT
15Button 2 Sequence FunctionFold 22 Bit2.1 switch controlCRT
15Button 2 Sequence FunctionFold 21 Byte5.10 counter pulses (0..255)CRT
15Button 2 Sequence FunctionFold 21 Byte5.1 percentage (0..100%)CRT
15Button 2 Sequence FunctionFold 22 Bytes7.1 pulsesCRT
15Button 2 Sequence FunctionFold 22 Bytes9.1 temperature (°C)CRT
15Button 2 Sequence FunctionFold 22 Bytes9.4 lux (Lux)CRT
15Button 2 Counter AlarmAlarm1 Bit1.5 alarmCRT
16Button 2 Long Press StatusStatus1 Bit1.1 switchCRW
17Button 2 Second ObjectSwitching 1Bit1 Bit1.1 switchCRT
17Button 2 Second ObjectSwitching 2Bit2 Bit2.1 switch controlCRT
17Button 2 Second ObjectSwitching 1Byte Value1 Byte5.10 counter pulses (0..255)CRT
17Button 2 Second ObjectSwitching Percent Value1 Byte5.1 percentage (0..100%)CRT
17Button 2 Second ObjectSwitching 2Byte Value2 Bytes7.1 pulsesCRT
17Button 2 Second ObjectTemperature Value2 Bytes9.1 temperature (°C)CRT
17Button 2 Second ObjectLux Value2 Bytes9.4 lux (Lux)CRT
17Button 2 Multiple OperationFold 31 Bit1.1 switchCRT
17Button 2 Multiple OperationFold 32 Bit2.1 switch controlCRT
17Button 2 Multiple OperationFold 31 Byte5.10 counter pulses (0..255)CRT
17Button 2 Multiple OperationFold 31 Byte5.1 percentage (0..100%)CRT
17Button 2 Multiple OperationFold 32 Bytes7.1 pulsesCRT
17Button 2 Multiple OperationFold 32 Bytes9.1 temperature (°C)CRT
17Button 2 Multiple OperationFold 32 Bytes9.4 lux (Lux)CRT
17Button 2 Sequence FunctionFold 31 Bit1.1 switchCRT
17Button 2 Sequence FunctionFold 32 Bit2.1 switch controlCRT
17Button 2 Sequence FunctionFold 31 Byte5.10 counter pulses (0..255)CRT
17Button 2 Sequence FunctionFold 31 Byte5.1 percentage (0..100%)CRT
17Button 2 Sequence FunctionFold 32 Bytes7.1 pulsesCRT
17Button 2 Sequence FunctionFold 32 Bytes9.1 temperature (°C)CRT
17Button 2 Sequence FunctionFold 32 Bytes9.4 lux (Lux)CRT
17Button 2 Counter2Byte Value2 Bytes7.1 pulsesCRWT
18Button 2 Second Object StatusStatus1 Bit1.1 switchCRW
18Button 2 Counter1Byte Value1 Byte5.10 counter pulses (0..255)CRWT
19Button 2 Multiple OperationFold 41 Bit1.1 switchCRT
19Button 2 Multiple OperationFold 42 Bit2.1 switch controlCRT
19Button 2 Multiple OperationFold 41 Byte5.10 counter pulses (0..255)CRT
19Button 2 Multiple OperationFold 41 Byte5.1 percentage (0..100%)CRT
19Button 2 Multiple OperationFold 42 Bytes7.1 pulsesCRT
19Button 2 Multiple OperationFold 42 Bytes9.1 temperature (°C)CRT
19Button 2 Multiple OperationFold 42 Bytes9.4 lux (Lux)CRT
19Button 2 Sequence FunctionFold 41 Bit1.1 switchCRT
19Button 2 Sequence FunctionFold 42 Bit2.1 switch controlCRT
19Button 2 Sequence FunctionFold 41 Byte5.10 counter pulses (0..255)CRT
19Button 2 Sequence FunctionFold 41 Byte5.1 percentage (0..100%)CRT
19Button 2 Sequence FunctionFold 42 Bytes7.1 pulsesCRT
19Button 2 Sequence FunctionFold 42 Bytes9.1 temperature (°C)CRT
19Button 2 Sequence FunctionFold 42 Bytes9.4 lux (Lux)CRT
19Button 2 Counter4Byte Value4 Bytes12.1 counter pulses (unsigned)CRWT
20Button 2 LockLock1 Bit1.3 enableCRW
21Button 2 LED statusStatus1 Bit1.1 switchCRW
24Button 2 Step CountLux Value2 Bytes9.4 lux (Lux)CRWTU
25Button 3 Short PressSwitching 1Bit1 Bit1.1 switchCRT
25Button 3 Short PressSwitching 2Bit2 Bit2.1 switch controlCRT
25Button 3 Short PressSwitching 1Byte Value1 Byte5.10 counter pulses (0..255)CRT
25Button 3 Short PressSwitching Percent Value1 Byte5.1 percentage (0..100%)CRT
25Button 3 Short PressSwitching 2Byte Value2 Bytes7.1 pulsesCRT
25Button 3 Short PressTemperature Value2 Bytes9.1 temperature (°C)CRT
25Button 3 Short PressLux Value2 Bytes9.4 lux (Lux)CRT
25Button 3 DimmingSwitch On Off1 Bit1.1 switchCRT
25Button 3 Blind/ShutterUp/Down1 Bit1.8 up/downCRT
25Button 3 SceneScene Control1 Byte18.1 scene controlCRT
25Button 3 Multiple OperationFold 11 Bit1.1 switchCRT
25Button 3 Multiple OperationFold 12 Bit2.1 switch controlCRT
25Button 3 Multiple OperationFold 11 Byte5.10 counter pulses (0..255)CRT
25Button 3 Multiple OperationFold 11 Byte5.1 percentage (0..100%)CRT
25Button 3 Multiple OperationFold 12 Bytes7.1 pulsesCRT
25Button 3 Multiple OperationFold 12 Bytes9.1 temperature (°C)CRT
25Button 3 Multiple OperationFold 12 Bytes9.4 lux (Lux)CRT
25Button 3 Sequence FunctionFold 11 Bit1.1 switchCRT
25Button 3 Sequence FunctionFold 12 Bit2.1 switch controlCRT
25Button 3 Sequence FunctionFold 11 Byte5.10 counter pulses (0..255)CRT
25Button 3 Sequence FunctionFold 11 Byte5.1 percentage (0..100%)CRT
25Button 3 Sequence FunctionFold 12 Bytes7.1 pulsesCRT
25Button 3 Sequence FunctionFold 12 Bytes9.1 temperature (°C)CRT
25Button 3 Sequence FunctionFold 12 Bytes9.4 lux (Lux)CRT
25Button 3 CounterRequest Value1 Bit1.17 triggerCW
25Button 3 Fan ControlFan Control1 Byte5.10 counter pulses (0..255)CRT
25Button 3 Fan ControlFan Control1 Byte5.1 percentage (0..100%)CRT
25Button 3 Operating ModeOperating Mode1 Byte20.102 HVAC modeCRT
25Button 3 Heat/CoolHeat/Cool1 Bit1.100 cooling/heatingCRT
25Button 3 Step Control1 Byte Value1 Byte5.10 counter pulses (0..255)CRT
25Button 3 Step Control1 Byte Percentage1 Byte5.1 percentage (0..100%)CRT
25Button 3 Step Control2 Byte Value2 Bytes7.1 pulsesCRT
25Button 3 Step ControlTemperature Value2 Bytes9.1 temperature (°C)CRT
25Button 3 Step ControlScene Value1 Byte18.1 scene controlCRT
25Button 3 Step ControlLux Value2 Bytes9.4 lux (Lux)CRT
25Button 3 External SetpointTemperature2 Bytes9.1 temperature (°C)CRT
25Button 3 HVAC ModeHVAC Mode1 Byte20.105 HVAC control modeCRT
26Button 3 Short Press StatusStatus1 Bit1.1 switchCRW
26Button 3 DimmingStatus1 Bit1.1 switchCRW
27Button 3 Long PressSwitching 1Bit1 Bit1.1 switchCRT
27Button 3 Long PressSwitching 2Bit2 Bit2.1 switch controlCRT
27Button 3 Long PressSwitching 1Byte Value1 Byte5.10 counter pulses (0..255)CRT
27Button 3 Long PressSwitching Percent Value1 Byte5.1 percentage (0..100%)CRT
27Button 3 Long PressSwitching 2Byte Value2 Bytes7.1 pulsesCRT
27Button 3 Long PressTemperature Value2 Bytes9.1 temperature (°C)CRT
27Button 3 Long PressLux Value2 Bytes9.4 lux (Lux)CRT
27Button 3 DimmingRelative Dimming4 Bit3.7 dimming controlCRT
27Button 3 Blind/ShutterStep/Stop1 Bit1.7 stepCRT
27Button 3 Multiple OperationFold 21 Bit1.1 switchCRT
27Button 3 Multiple OperationFold 22 Bit2.1 switch controlCRT
27Button 3 Multiple OperationFold 21 Byte5.10 counter pulses (0..255)CRT
27Button 3 Multiple OperationFold 21 Byte5.1 percentage (0..100%)CRT
27Button 3 Multiple OperationFold 22 Bytes7.1 pulsesCRT
27Button 3 Multiple OperationFold 22 Bytes9.1 temperature (°C)CRT
27Button 3 Multiple OperationFold 22 Bytes9.4 lux (Lux)CRT
27Button 3 Sequence FunctionFold 21 Bit1.1 switchCRT
27Button 3 Sequence FunctionFold 22 Bit2.1 switch controlCRT
27Button 3 Sequence FunctionFold 21 Byte5.10 counter pulses (0..255)CRT
27Button 3 Sequence FunctionFold 21 Byte5.1 percentage (0..100%)CRT
27Button 3 Sequence FunctionFold 22 Bytes7.1 pulsesCRT
27Button 3 Sequence FunctionFold 22 Bytes9.1 temperature (°C)CRT
27Button 3 Sequence FunctionFold 22 Bytes9.4 lux (Lux)CRT
27Button 3 Counter AlarmAlarm1 Bit1.5 alarmCRT
28Button 3 Long Press StatusStatus1 Bit1.1 switchCRW
29Button 3 Second ObjectSwitching 1Bit1 Bit1.1 switchCRT
29Button 3 Second ObjectSwitching 2Bit2 Bit2.1 switch controlCRT
29Button 3 Second ObjectSwitching 1Byte Value1 Byte5.10 counter pulses (0..255)CRT
29Button 3 Second ObjectSwitching Percent Value1 Byte5.1 percentage (0..100%)CRT
29Button 3 Second ObjectSwitching 2Byte Value2 Bytes7.1 pulsesCRT
29Button 3 Second ObjectTemperature Value2 Bytes9.1 temperature (°C)CRT
29Button 3 Second ObjectLux Value2 Bytes9.4 lux (Lux)CRT
29Button 3 Multiple OperationFold 31 Bit1.1 switchCRT
29Button 3 Multiple OperationFold 32 Bit2.1 switch controlCRT
29Button 3 Multiple OperationFold 31 Byte5.10 counter pulses (0..255)CRT
29Button 3 Multiple OperationFold 31 Byte5.1 percentage (0..100%)CRT
29Button 3 Multiple OperationFold 32 Bytes7.1 pulsesCRT
29Button 3 Multiple OperationFold 32 Bytes9.1 temperature (°C)CRT
29Button 3 Multiple OperationFold 32 Bytes9.4 lux (Lux)CRT
29Button 3 Sequence FunctionFold 31 Bit1.1 switchCRT
29Button 3 Sequence FunctionFold 32 Bit2.1 switch controlCRT
29Button 3 Sequence FunctionFold 31 Byte5.10 counter pulses (0..255)CRT
29Button 3 Sequence FunctionFold 31 Byte5.1 percentage (0..100%)CRT
29Button 3 Sequence FunctionFold 32 Bytes7.1 pulsesCRT
29Button 3 Sequence FunctionFold 32 Bytes9.1 temperature (°C)CRT
29Button 3 Sequence FunctionFold 32 Bytes9.4 lux (Lux)CRT
29Button 3 Counter2Byte Value2 Bytes7.1 pulsesCRWT
30Button 3 Second Object StatusStatus1 Bit1.1 switchCRW
30Button 3 Counter1Byte Value1 Byte5.10 counter pulses (0..255)CRWT
31Button 3 Multiple OperationFold 41 Bit1.1 switchCRT
31Button 3 Multiple OperationFold 42 Bit2.1 switch controlCRT
31Button 3 Multiple OperationFold 41 Byte5.10 counter pulses (0..255)CRT
31Button 3 Multiple OperationFold 41 Byte5.1 percentage (0..100%)CRT
31Button 3 Multiple OperationFold 42 Bytes7.1 pulsesCRT
31Button 3 Multiple OperationFold 42 Bytes9.1 temperature (°C)CRT
31Button 3 Multiple OperationFold 42 Bytes9.4 lux (Lux)CRT
31Button 3 Sequence FunctionFold 41 Bit1.1 switchCRT
31Button 3 Sequence FunctionFold 42 Bit2.1 switch controlCRT
31Button 3 Sequence FunctionFold 41 Byte5.10 counter pulses (0..255)CRT
31Button 3 Sequence FunctionFold 41 Byte5.1 percentage (0..100%)CRT
31Button 3 Sequence FunctionFold 42 Bytes7.1 pulsesCRT
31Button 3 Sequence FunctionFold 42 Bytes9.1 temperature (°C)CRT
31Button 3 Sequence FunctionFold 42 Bytes9.4 lux (Lux)CRT
31Button 3 Counter4Byte Value4 Bytes12.1 counter pulses (unsigned)CRWT
32Button 3 LockLock1 Bit1.3 enableCRW
33Button 3 LED statusStatus1 Bit1.1 switchCRW
36Button 3 Step CountLux Value2 Bytes9.4 lux (Lux)CRWTU
37Button 4 Short PressSwitching 1Bit1 Bit1.1 switchCRT
37Button 4 Short PressSwitching 2Bit2 Bit2.1 switch controlCRT
37Button 4 Short PressSwitching 1Byte Value1 Byte5.10 counter pulses (0..255)CRT
37Button 4 Short PressSwitching Percent Value1 Byte5.1 percentage (0..100%)CRT
37Button 4 Short PressSwitching 2Byte Value2 Bytes7.1 pulsesCRT
37Button 4 Short PressTemperature Value2 Bytes9.1 temperature (°C)CRT
37Button 4 Short PressLux Value2 Bytes9.4 lux (Lux)CRT
37Button 4 DimmingSwitch On Off1 Bit1.1 switchCRT
37Button 4 Blind/ShutterUp/Down1 Bit1.8 up/downCRT
37Button 4 SceneScene Control1 Byte18.1 scene controlCRT
37Button 4 Multiple OperationFold 11 Bit1.1 switchCRT
37Button 4 Multiple OperationFold 12 Bit2.1 switch controlCRT
37Button 4 Multiple OperationFold 11 Byte5.10 counter pulses (0..255)CRT
37Button 4 Multiple OperationFold 11 Byte5.1 percentage (0..100%)CRT
37Button 4 Multiple OperationFold 12 Bytes7.1 pulsesCRT
37Button 4 Multiple OperationFold 12 Bytes9.1 temperature (°C)CRT
37Button 4 Multiple OperationFold 12 Bytes9.4 lux (Lux)CRT
37Button 4 Sequence FunctionFold 11 Bit1.1 switchCRT
37Button 4 Sequence FunctionFold 12 Bit2.1 switch controlCRT
37Button 4 Sequence FunctionFold 11 Byte5.10 counter pulses (0..255)CRT
37Button 4 Sequence FunctionFold 11 Byte5.1 percentage (0..100%)CRT
37Button 4 Sequence FunctionFold 12 Bytes7.1 pulsesCRT
37Button 4 Sequence FunctionFold 12 Bytes9.1 temperature (°C)CRT
37Button 4 Sequence FunctionFold 12 Bytes9.4 lux (Lux)CRT
37Button 4 CounterRequest Value1 Bit1.17 triggerCW
37Button 4 Fan ControlFan Control1 Byte5.10 counter pulses (0..255)CRT
37Button 4 Fan ControlFan Control1 Byte5.1 percentage (0..100%)CRT
37Button 4 Operating ModeOperating Mode1 Byte20.102 HVAC modeCRT
37Button 4 Heat/CoolHeat/Cool1 Bit1.100 cooling/heatingCRT
37Button 4 Step Control1 Byte Value1 Byte5.10 counter pulses (0..255)CRT
37Button 4 Step Control1 Byte Percentage1 Byte5.1 percentage (0..100%)CRT
37Button 4 Step Control2 Byte Value2 Bytes7.1 pulsesCRT
37Button 4 Step ControlTemperature Value2 Bytes9.1 temperature (°C)CRT
37Button 4 Step ControlScene Value1 Byte18.1 scene controlCRT
37Button 4 Step ControlLux Value2 Bytes9.4 lux (Lux)CRT
37Button 4 External SetpointTemperature2 Bytes9.1 temperature (°C)CRT
37Button 4 HVAC ModeHVAC Mode1 Byte20.105 HVAC control modeCRT
38Button 4 Short Press StatusStatus1 Bit1.1 switchCRW
38Button 4 DimmingStatus1 Bit1.1 switchCRW
39Button 4 Long PressSwitching 1Bit1 Bit1.1 switchCRT
39Button 4 Long PressSwitching 2Bit2 Bit2.1 switch controlCRT
39Button 4 Long PressSwitching 1Byte Value1 Byte5.10 counter pulses (0..255)CRT
39Button 4 Long PressSwitching Percent Value1 Byte5.1 percentage (0..100%)CRT
39Button 4 Long PressSwitching 2Byte Value2 Bytes7.1 pulsesCRT
39Button 4 Long PressTemperature Value2 Bytes9.1 temperature (°C)CRT
39Button 4 Long PressLux Value2 Bytes9.4 lux (Lux)CRT
39Button 4 DimmingRelative Dimming4 Bit3.7 dimming controlCRT
39Button 4 Blind/ShutterStep/Stop1 Bit1.7 stepCRT
39Button 4 Multiple OperationFold 21 Bit1.1 switchCRT
39Button 4 Multiple OperationFold 22 Bit2.1 switch controlCRT
39Button 4 Multiple OperationFold 21 Byte5.10 counter pulses (0..255)CRT
39Button 4 Multiple OperationFold 21 Byte5.1 percentage (0..100%)CRT
39Button 4 Multiple OperationFold 22 Bytes7.1 pulsesCRT
39Button 4 Multiple OperationFold 22 Bytes9.1 temperature (°C)CRT
39Button 4 Multiple OperationFold 22 Bytes9.4 lux (Lux)CRT
39Button 4 Sequence FunctionFold 21 Bit1.1 switchCRT
39Button 4 Sequence FunctionFold 22 Bit2.1 switch controlCRT
39Button 4 Sequence FunctionFold 21 Byte5.10 counter pulses (0..255)CRT
39Button 4 Sequence FunctionFold 21 Byte5.1 percentage (0..100%)CRT
39Button 4 Sequence FunctionFold 22 Bytes7.1 pulsesCRT
39Button 4 Sequence FunctionFold 22 Bytes9.1 temperature (°C)CRT
39Button 4 Sequence FunctionFold 22 Bytes9.4 lux (Lux)CRT
39Button 4 Counter AlarmAlarm1 Bit1.5 alarmCRT
40Button 4 Long Press StatusStatus1 Bit1.1 switchCRW
41Button 4 Second ObjectSwitching 1Bit1 Bit1.1 switchCRT
41Button 4 Second ObjectSwitching 2Bit2 Bit2.1 switch controlCRT
41Button 4 Second ObjectSwitching 1Byte Value1 Byte5.10 counter pulses (0..255)CRT
41Button 4 Second ObjectSwitching Percent Value1 Byte5.1 percentage (0..100%)CRT
41Button 4 Second ObjectSwitching 2Byte Value2 Bytes7.1 pulsesCRT
41Button 4 Second ObjectTemperature Value2 Bytes9.1 temperature (°C)CRT
41Button 4 Second ObjectLux Value2 Bytes9.4 lux (Lux)CRT
41Button 4 Multiple OperationFold 31 Bit1.1 switchCRT
41Button 4 Multiple OperationFold 32 Bit2.1 switch controlCRT
41Button 4 Multiple OperationFold 31 Byte5.10 counter pulses (0..255)CRT
41Button 4 Multiple OperationFold 31 Byte5.1 percentage (0..100%)CRT
41Button 4 Multiple OperationFold 32 Bytes7.1 pulsesCRT
41Button 4 Multiple OperationFold 32 Bytes9.1 temperature (°C)CRT
41Button 4 Multiple OperationFold 32 Bytes9.4 lux (Lux)CRT
41Button 4 Sequence FunctionFold 31 Bit1.1 switchCRT
41Button 4 Sequence FunctionFold 32 Bit2.1 switch controlCRT
41Button 4 Sequence FunctionFold 31 Byte5.10 counter pulses (0..255)CRT
41Button 4 Sequence FunctionFold 31 Byte5.1 percentage (0..100%)CRT
41Button 4 Sequence FunctionFold 32 Bytes7.1 pulsesCRT
41Button 4 Sequence FunctionFold 32 Bytes9.1 temperature (°C)CRT
41Button 4 Sequence FunctionFold 32 Bytes9.4 lux (Lux)CRT
41Button 4 Counter2Byte Value2 Bytes7.1 pulsesCRWT
42Button 4 Second Object StatusStatus1 Bit1.1 switchCRW
42Button 4 Counter1Byte Value1 Byte5.10 counter pulses (0..255)CRWT
43Button 4 Multiple OperationFold 41 Bit1.1 switchCRT
43Button 4 Multiple OperationFold 42 Bit2.1 switch controlCRT
43Button 4 Multiple OperationFold 41 Byte5.10 counter pulses (0..255)CRT
43Button 4 Multiple OperationFold 41 Byte5.1 percentage (0..100%)CRT
43Button 4 Multiple OperationFold 42 Bytes7.1 pulsesCRT
43Button 4 Multiple OperationFold 42 Bytes9.1 temperature (°C)CRT
43Button 4 Multiple OperationFold 42 Bytes9.4 lux (Lux)CRT
43Button 4 Sequence FunctionFold 41 Bit1.1 switchCRT
43Button 4 Sequence FunctionFold 42 Bit2.1 switch controlCRT
43Button 4 Sequence FunctionFold 41 Byte5.10 counter pulses (0..255)CRT
43Button 4 Sequence FunctionFold 41 Byte5.1 percentage (0..100%)CRT
43Button 4 Sequence FunctionFold 42 Bytes7.1 pulsesCRT
43Button 4 Sequence FunctionFold 42 Bytes9.1 temperature (°C)CRT
43Button 4 Sequence FunctionFold 42 Bytes9.4 lux (Lux)CRT
43Button 4 Counter4Byte Value4 Bytes12.1 counter pulses (unsigned)CRWT
44Button 4 LockLock1 Bit1.3 enableCRW
45Button 4 LED statusStatus1 Bit1.1 switchCRW
48Button 4 Step CountLux Value2 Bytes9.4 lux (Lux)CRWTU
49Button 5 Short PressSwitching 1Bit1 Bit1.1 switchCRT
49Button 5 Short PressSwitching 2Bit2 Bit2.1 switch controlCRT
49Button 5 Short PressSwitching 1Byte Value1 Byte5.10 counter pulses (0..255)CRT
49Button 5 Short PressSwitching Percent Value1 Byte5.1 percentage (0..100%)CRT
49Button 5 Short PressSwitching 2Byte Value2 Bytes7.1 pulsesCRT
49Button 5 Short PressTemperature Value2 Bytes9.1 temperature (°C)CRT
49Button 5 Short PressLux Value2 Bytes9.4 lux (Lux)CRT
49Button 5 DimmingSwitch On Off1 Bit1.1 switchCRT
49Button 5 Blind/ShutterUp/Down1 Bit1.8 up/downCRT
49Button 5 SceneScene Control1 Byte18.1 scene controlCRT
49Button 5 Multiple OperationFold 11 Bit1.1 switchCRT
49Button 5 Multiple OperationFold 12 Bit2.1 switch controlCRT
49Button 5 Multiple OperationFold 11 Byte5.10 counter pulses (0..255)CRT
49Button 5 Multiple OperationFold 11 Byte5.1 percentage (0..100%)CRT
49Button 5 Multiple OperationFold 12 Bytes7.1 pulsesCRT
49Button 5 Multiple OperationFold 12 Bytes9.1 temperature (°C)CRT
49Button 5 Multiple OperationFold 12 Bytes9.4 lux (Lux)CRT
49Button 5 Sequence FunctionFold 11 Bit1.1 switchCRT
49Button 5 Sequence FunctionFold 12 Bit2.1 switch controlCRT
49Button 5 Sequence FunctionFold 11 Byte5.10 counter pulses (0..255)CRT
49Button 5 Sequence FunctionFold 11 Byte5.1 percentage (0..100%)CRT
49Button 5 Sequence FunctionFold 12 Bytes7.1 pulsesCRT
49Button 5 Sequence FunctionFold 12 Bytes9.1 temperature (°C)CRT
49Button 5 Sequence FunctionFold 12 Bytes9.4 lux (Lux)CRT
49Button 5 CounterRequest Value1 Bit1.17 triggerCW
49Button 5 Fan ControlFan Control1 Byte5.10 counter pulses (0..255)CRT
49Button 5 Fan ControlFan Control1 Byte5.1 percentage (0..100%)CRT
49Button 5 Operating ModeOperating Mode1 Byte20.102 HVAC modeCRT
49Button 5 Heat/CoolHeat/Cool1 Bit1.100 cooling/heatingCRT
49Button 5 Step Control1 Byte Value1 Byte5.10 counter pulses (0..255)CRT
49Button 5 Step Control1 Byte Percentage1 Byte5.1 percentage (0..100%)CRT
49Button 5 Step Control2 Byte Value2 Bytes7.1 pulsesCRT
49Button 5 Step ControlTemperature Value2 Bytes9.1 temperature (°C)CRT
49Button 5 Step ControlScene Value1 Byte18.1 scene controlCRT
49Button 5 Step ControlLux Value2 Bytes9.4 lux (Lux)CRT
49Button 5 External SetpointTemperature2 Bytes9.1 temperature (°C)CRT
49Button 5 HVAC ModeHVAC Mode1 Byte20.105 HVAC control modeCRT
50Button 5 Short Press StatusStatus1 Bit1.1 switchCRW
50Button 5 DimmingStatus1 Bit1.1 switchCRW
51Button 5 Long PressSwitching 1Bit1 Bit1.1 switchCRT
51Button 5 Long PressSwitching 2Bit2 Bit2.1 switch controlCRT
51Button 5 Long PressSwitching 1Byte Value1 Byte5.10 counter pulses (0..255)CRT
51Button 5 Long PressSwitching Percent Value1 Byte5.1 percentage (0..100%)CRT
51Button 5 Long PressSwitching 2Byte Value2 Bytes7.1 pulsesCRT
51Button 5 Long PressTemperature Value2 Bytes9.1 temperature (°C)CRT
51Button 5 Long PressLux Value2 Bytes9.4 lux (Lux)CRT
51Button 5 DimmingRelative Dimming4 Bit3.7 dimming controlCRT
51Button 5 Blind/ShutterStep/Stop1 Bit1.7 stepCRT
51Button 5 Multiple OperationFold 21 Bit1.1 switchCRT
51Button 5 Multiple OperationFold 22 Bit2.1 switch controlCRT
51Button 5 Multiple OperationFold 21 Byte5.10 counter pulses (0..255)CRT
51Button 5 Multiple OperationFold 21 Byte5.1 percentage (0..100%)CRT
51Button 5 Multiple OperationFold 22 Bytes7.1 pulsesCRT
51Button 5 Multiple OperationFold 22 Bytes9.1 temperature (°C)CRT
51Button 5 Multiple OperationFold 22 Bytes9.4 lux (Lux)CRT
51Button 5 Sequence FunctionFold 21 Bit1.1 switchCRT
51Button 5 Sequence FunctionFold 22 Bit2.1 switch controlCRT
51Button 5 Sequence FunctionFold 21 Byte5.10 counter pulses (0..255)CRT
51Button 5 Sequence FunctionFold 21 Byte5.1 percentage (0..100%)CRT
51Button 5 Sequence FunctionFold 22 Bytes7.1 pulsesCRT
51Button 5 Sequence FunctionFold 22 Bytes9.1 temperature (°C)CRT
51Button 5 Sequence FunctionFold 22 Bytes9.4 lux (Lux)CRT
51Button 5 Counter AlarmAlarm1 Bit1.5 alarmCRT
52Button 5 Long Press StatusStatus1 Bit1.1 switchCRW
53Button 5 Second ObjectSwitching 1Bit1 Bit1.1 switchCRT
53Button 5 Second ObjectSwitching 2Bit2 Bit2.1 switch controlCRT
53Button 5 Second ObjectSwitching 1Byte Value1 Byte5.10 counter pulses (0..255)CRT
53Button 5 Second ObjectSwitching Percent Value1 Byte5.1 percentage (0..100%)CRT
53Button 5 Second ObjectSwitching 2Byte Value2 Bytes7.1 pulsesCRT
53Button 5 Second ObjectTemperature Value2 Bytes9.1 temperature (°C)CRT
53Button 5 Second ObjectLux Value2 Bytes9.4 lux (Lux)CRT
53Button 5 Multiple OperationFold 31 Bit1.1 switchCRT
53Button 5 Multiple OperationFold 32 Bit2.1 switch controlCRT
53Button 5 Multiple OperationFold 31 Byte5.10 counter pulses (0..255)CRT
53Button 5 Multiple OperationFold 31 Byte5.1 percentage (0..100%)CRT
53Button 5 Multiple OperationFold 32 Bytes7.1 pulsesCRT
53Button 5 Multiple OperationFold 32 Bytes9.1 temperature (°C)CRT
53Button 5 Multiple OperationFold 32 Bytes9.4 lux (Lux)CRT
53Button 5 Sequence FunctionFold 31 Bit1.1 switchCRT
53Button 5 Sequence FunctionFold 32 Bit2.1 switch controlCRT
53Button 5 Sequence FunctionFold 31 Byte5.10 counter pulses (0..255)CRT
53Button 5 Sequence FunctionFold 31 Byte5.1 percentage (0..100%)CRT
53Button 5 Sequence FunctionFold 32 Bytes7.1 pulsesCRT
53Button 5 Sequence FunctionFold 32 Bytes9.1 temperature (°C)CRT
53Button 5 Sequence FunctionFold 32 Bytes9.4 lux (Lux)CRT
53Button 5 Counter2Byte Value2 Bytes7.1 pulsesCRWT
54Button 5 Second Object StatusStatus1 Bit1.1 switchCRW
54Button 5 Counter1Byte Value1 Byte5.10 counter pulses (0..255)CRWT
55Button 5 Multiple OperationFold 41 Bit1.1 switchCRT
55Button 5 Multiple OperationFold 42 Bit2.1 switch controlCRT
55Button 5 Multiple OperationFold 41 Byte5.10 counter pulses (0..255)CRT
55Button 5 Multiple OperationFold 41 Byte5.1 percentage (0..100%)CRT
55Button 5 Multiple OperationFold 42 Bytes7.1 pulsesCRT
55Button 5 Multiple OperationFold 42 Bytes9.1 temperature (°C)CRT
55Button 5 Multiple OperationFold 42 Bytes9.4 lux (Lux)CRT
55Button 5 Sequence FunctionFold 41 Bit1.1 switchCRT
55Button 5 Sequence FunctionFold 42 Bit2.1 switch controlCRT
55Button 5 Sequence FunctionFold 41 Byte5.10 counter pulses (0..255)CRT
55Button 5 Sequence FunctionFold 41 Byte5.1 percentage (0..100%)CRT
55Button 5 Sequence FunctionFold 42 Bytes7.1 pulsesCRT
55Button 5 Sequence FunctionFold 42 Bytes9.1 temperature (°C)CRT
55Button 5 Sequence FunctionFold 42 Bytes9.4 lux (Lux)CRT
55Button 5 Counter4Byte Value4 Bytes12.1 counter pulses (unsigned)CRWT
56Button 5 LockLock1 Bit1.3 enableCRW
57Button 5 LED statusStatus1 Bit1.1 switchCRW
60Button 5 Step CountLux Value2 Bytes9.4 lux (Lux)CRWTU
61Button 6 Short PressSwitching 1Bit1 Bit1.1 switchCRT
61Button 6 Short PressSwitching 2Bit2 Bit2.1 switch controlCRT
61Button 6 Short PressSwitching 1Byte Value1 Byte5.10 counter pulses (0..255)CRT
61Button 6 Short PressSwitching Percent Value1 Byte5.1 percentage (0..100%)CRT
61Button 6 Short PressSwitching 2Byte Value2 Bytes7.1 pulsesCRT
61Button 6 Short PressTemperature Value2 Bytes9.1 temperature (°C)CRT
61Button 6 Short PressLux Value2 Bytes9.4 lux (Lux)CRT
61Button 6 DimmingSwitch On Off1 Bit1.1 switchCRT
61Button 6 Blind/ShutterUp/Down1 Bit1.8 up/downCRT
61Button 6 SceneScene Control1 Byte18.1 scene controlCRT
61Button 6 Multiple OperationFold 11 Bit1.1 switchCRT
61Button 6 Multiple OperationFold 12 Bit2.1 switch controlCRT
61Button 6 Multiple OperationFold 11 Byte5.10 counter pulses (0..255)CRT
61Button 6 Multiple OperationFold 11 Byte5.1 percentage (0..100%)CRT
61Button 6 Multiple OperationFold 12 Bytes7.1 pulsesCRT
61Button 6 Multiple OperationFold 12 Bytes9.1 temperature (°C)CRT
61Button 6 Multiple OperationFold 12 Bytes9.4 lux (Lux)CRT
61Button 6 Sequence FunctionFold 11 Bit1.1 switchCRT
61Button 6 Sequence FunctionFold 12 Bit2.1 switch controlCRT
61Button 6 Sequence FunctionFold 11 Byte5.10 counter pulses (0..255)CRT
61Button 6 Sequence FunctionFold 11 Byte5.1 percentage (0..100%)CRT
61Button 6 Sequence FunctionFold 12 Bytes7.1 pulsesCRT
61Button 6 Sequence FunctionFold 12 Bytes9.1 temperature (°C)CRT
61Button 6 Sequence FunctionFold 12 Bytes9.4 lux (Lux)CRT
61Button 6 CounterRequest Value1 Bit1.17 triggerCW
61Button 6 Fan ControlFan Control1 Byte5.10 counter pulses (0..255)CRT
61Button 6 Fan ControlFan Control1 Byte5.1 percentage (0..100%)CRT
61Button 6 Operating ModeOperating Mode1 Byte20.102 HVAC modeCRT
61Button 6 Heat/CoolHeat/Cool1 Bit1.100 cooling/heatingCRT
61Button 6 Step Control1 Byte Value1 Byte5.10 counter pulses (0..255)CRT
61Button 6 Step Control1 Byte Percentage1 Byte5.1 percentage (0..100%)CRT
61Button 6 Step Control2 Byte Value2 Bytes7.1 pulsesCRT
61Button 6 Step ControlTemperature Value2 Bytes9.1 temperature (°C)CRT
61Button 6 Step ControlScene Value1 Byte18.1 scene controlCRT
61Button 6 Step ControlLux Value2 Bytes9.4 lux (Lux)CRT
61Button 6 External SetpointTemperature2 Bytes9.1 temperature (°C)CRT
61Button 6 HVAC ModeHVAC Mode1 Byte20.105 HVAC control modeCRT
62Button 6 Short Press StatusStatus1 Bit1.1 switchCRW
62Button 6 DimmingStatus1 Bit1.1 switchCRW
63Button 6 Long PressSwitching 1Bit1 Bit1.1 switchCRT
63Button 6 Long PressSwitching 2Bit2 Bit2.1 switch controlCRT
63Button 6 Long PressSwitching 1Byte Value1 Byte5.10 counter pulses (0..255)CRT
63Button 6 Long PressSwitching Percent Value1 Byte5.1 percentage (0..100%)CRT
63Button 6 Long PressSwitching 2Byte Value2 Bytes7.1 pulsesCRT
63Button 6 Long PressTemperature Value2 Bytes9.1 temperature (°C)CRT
63Button 6 Long PressLux Value2 Bytes9.4 lux (Lux)CRT
63Button 6 DimmingRelative Dimming4 Bit3.7 dimming controlCRT
63Button 6 Blind/ShutterStep/Stop1 Bit1.7 stepCRT
63Button 6 Multiple OperationFold 21 Bit1.1 switchCRT
63Button 6 Multiple OperationFold 22 Bit2.1 switch controlCRT
63Button 6 Multiple OperationFold 21 Byte5.10 counter pulses (0..255)CRT
63Button 6 Multiple OperationFold 21 Byte5.1 percentage (0..100%)CRT
63Button 6 Multiple OperationFold 22 Bytes7.1 pulsesCRT
63Button 6 Multiple OperationFold 22 Bytes9.1 temperature (°C)CRT
63Button 6 Multiple OperationFold 22 Bytes9.4 lux (Lux)CRT
63Button 6 Sequence FunctionFold 21 Bit1.1 switchCRT
63Button 6 Sequence FunctionFold 22 Bit2.1 switch controlCRT
63Button 6 Sequence FunctionFold 21 Byte5.10 counter pulses (0..255)CRT
63Button 6 Sequence FunctionFold 21 Byte5.1 percentage (0..100%)CRT
63Button 6 Sequence FunctionFold 22 Bytes7.1 pulsesCRT
63Button 6 Sequence FunctionFold 22 Bytes9.1 temperature (°C)CRT
63Button 6 Sequence FunctionFold 22 Bytes9.4 lux (Lux)CRT
63Button 6 Counter AlarmAlarm1 Bit1.5 alarmCRT
64Button 6 Long Press StatusStatus1 Bit1.1 switchCRW
65Button 6 Second ObjectSwitching 1Bit1 Bit1.1 switchCRT
65Button 6 Second ObjectSwitching 2Bit2 Bit2.1 switch controlCRT
65Button 6 Second ObjectSwitching 1Byte Value1 Byte5.10 counter pulses (0..255)CRT
65Button 6 Second ObjectSwitching Percent Value1 Byte5.1 percentage (0..100%)CRT
65Button 6 Second ObjectSwitching 2Byte Value2 Bytes7.1 pulsesCRT
65Button 6 Second ObjectTemperature Value2 Bytes9.1 temperature (°C)CRT
65Button 6 Second ObjectLux Value2 Bytes9.4 lux (Lux)CRT
65Button 6 Multiple OperationFold 31 Bit1.1 switchCRT
65Button 6 Multiple OperationFold 32 Bit2.1 switch controlCRT
65Button 6 Multiple OperationFold 31 Byte5.10 counter pulses (0..255)CRT
65Button 6 Multiple OperationFold 31 Byte5.1 percentage (0..100%)CRT
65Button 6 Multiple OperationFold 32 Bytes7.1 pulsesCRT
65Button 6 Multiple OperationFold 32 Bytes9.1 temperature (°C)CRT
65Button 6 Multiple OperationFold 32 Bytes9.4 lux (Lux)CRT
65Button 6 Sequence FunctionFold 31 Bit1.1 switchCRT
65Button 6 Sequence FunctionFold 32 Bit2.1 switch controlCRT
65Button 6 Sequence FunctionFold 31 Byte5.10 counter pulses (0..255)CRT
65Button 6 Sequence FunctionFold 31 Byte5.1 percentage (0..100%)CRT
65Button 6 Sequence FunctionFold 32 Bytes7.1 pulsesCRT
65Button 6 Sequence FunctionFold 32 Bytes9.1 temperature (°C)CRT
65Button 6 Sequence FunctionFold 32 Bytes9.4 lux (Lux)CRT
65Button 6 Counter2Byte Value2 Bytes7.1 pulsesCRWT
66Button 6 Second Object StatusStatus1 Bit1.1 switchCRW
66Button 6 Counter1Byte Value1 Byte5.10 counter pulses (0..255)CRWT
67Button 6 Multiple OperationFold 41 Bit1.1 switchCRT
67Button 6 Multiple OperationFold 42 Bit2.1 switch controlCRT
67Button 6 Multiple OperationFold 41 Byte5.10 counter pulses (0..255)CRT
67Button 6 Multiple OperationFold 41 Byte5.1 percentage (0..100%)CRT
67Button 6 Multiple OperationFold 42 Bytes7.1 pulsesCRT
67Button 6 Multiple OperationFold 42 Bytes9.1 temperature (°C)CRT
67Button 6 Multiple OperationFold 42 Bytes9.4 lux (Lux)CRT
67Button 6 Sequence FunctionFold 41 Bit1.1 switchCRT
67Button 6 Sequence FunctionFold 42 Bit2.1 switch controlCRT
67Button 6 Sequence FunctionFold 41 Byte5.10 counter pulses (0..255)CRT
67Button 6 Sequence FunctionFold 41 Byte5.1 percentage (0..100%)CRT
67Button 6 Sequence FunctionFold 42 Bytes7.1 pulsesCRT
67Button 6 Sequence FunctionFold 42 Bytes9.1 temperature (°C)CRT
67Button 6 Sequence FunctionFold 42 Bytes9.4 lux (Lux)CRT
67Button 6 Counter4Byte Value4 Bytes12.1 counter pulses (unsigned)CRWT
68Button 6 LockLock1 Bit1.3 enableCRW
69Button 6 LED statusStatus1 Bit1.1 switchCRW
72Button 6 Step CountLux Value2 Bytes9.4 lux (Lux)CRWTU
73Button 7 Short PressSwitching 1Bit1 Bit1.1 switchCRT
73Button 7 Short PressSwitching 2Bit2 Bit2.1 switch controlCRT
73Button 7 Short PressSwitching 1Byte Value1 Byte5.10 counter pulses (0..255)CRT
73Button 7 Short PressSwitching Percent Value1 Byte5.1 percentage (0..100%)CRT
73Button 7 Short PressSwitching 2Byte Value2 Bytes7.1 pulsesCRT
73Button 7 Short PressTemperature Value2 Bytes9.1 temperature (°C)CRT
73Button 7 Short PressLux Value2 Bytes9.4 lux (Lux)CRT
73Button 7 DimmingSwitch On Off1 Bit1.1 switchCRT
73Button 7 Blind/ShutterUp/Down1 Bit1.8 up/downCRT
73Button 7 SceneScene Control1 Byte18.1 scene controlCRT
73Button 7 Multiple OperationFold 11 Bit1.1 switchCRT
73Button 7 Multiple OperationFold 12 Bit2.1 switch controlCRT
73Button 7 Multiple OperationFold 11 Byte5.10 counter pulses (0..255)CRT
73Button 7 Multiple OperationFold 11 Byte5.1 percentage (0..100%)CRT
73Button 7 Multiple OperationFold 12 Bytes7.1 pulsesCRT
73Button 7 Multiple OperationFold 12 Bytes9.1 temperature (°C)CRT
73Button 7 Multiple OperationFold 12 Bytes9.4 lux (Lux)CRT
73Button 7 Sequence FunctionFold 11 Bit1.1 switchCRT
73Button 7 Sequence FunctionFold 12 Bit2.1 switch controlCRT
73Button 7 Sequence FunctionFold 11 Byte5.10 counter pulses (0..255)CRT
73Button 7 Sequence FunctionFold 11 Byte5.1 percentage (0..100%)CRT
73Button 7 Sequence FunctionFold 12 Bytes7.1 pulsesCRT
73Button 7 Sequence FunctionFold 12 Bytes9.1 temperature (°C)CRT
73Button 7 Sequence FunctionFold 12 Bytes9.4 lux (Lux)CRT
73Button 7 CounterRequest Value1 Bit1.17 triggerCW
73Button 7 Fan ControlFan Control1 Byte5.10 counter pulses (0..255)CRT
73Button 7 Fan ControlFan Control1 Byte5.1 percentage (0..100%)CRT
73Button 7 Operating ModeOperating Mode1 Byte20.102 HVAC modeCRT
73Button 7 Heat/CoolHeat/Cool1 Bit1.100 cooling/heatingCRT
73Button 7 Step Control1 Byte Value1 Byte5.10 counter pulses (0..255)CRT
73Button 7 Step Control1 Byte Percentage1 Byte5.1 percentage (0..100%)CRT
73Button 7 Step Control2 Byte Value2 Bytes7.1 pulsesCRT
73Button 7 Step ControlTemperature Value2 Bytes9.1 temperature (°C)CRT
73Button 7 Step ControlScene Value1 Byte18.1 scene controlCRT
73Button 7 Step ControlLux Value2 Bytes9.4 lux (Lux)CRT
73Button 7 External SetpointTemperature2 Bytes9.1 temperature (°C)CRT
73Button 7 HVAC ModeHVAC Mode1 Byte20.105 HVAC control modeCRT
74Button 7 Short Press StatusStatus1 Bit1.1 switchCRW
74Button 7 DimmingStatus1 Bit1.1 switchCRW
75Button 7 Long PressSwitching 1Bit1 Bit1.1 switchCRT
75Button 7 Long PressSwitching 2Bit2 Bit2.1 switch controlCRT
75Button 7 Long PressSwitching 1Byte Value1 Byte5.10 counter pulses (0..255)CRT
75Button 7 Long PressSwitching Percent Value1 Byte5.1 percentage (0..100%)CRT
75Button 7 Long PressSwitching 2Byte Value2 Bytes7.1 pulsesCRT
75Button 7 Long PressTemperature Value2 Bytes9.1 temperature (°C)CRT
75Button 7 Long PressLux Value2 Bytes9.4 lux (Lux)CRT
75Button 7 DimmingRelative Dimming4 Bit3.7 dimming controlCRT
75Button 7 Blind/ShutterStep/Stop1 Bit1.7 stepCRT
75Button 7 Multiple OperationFold 21 Bit1.1 switchCRT
75Button 7 Multiple OperationFold 22 Bit2.1 switch controlCRT
75Button 7 Multiple OperationFold 21 Byte5.10 counter pulses (0..255)CRT
75Button 7 Multiple OperationFold 21 Byte5.1 percentage (0..100%)CRT
75Button 7 Multiple OperationFold 22 Bytes7.1 pulsesCRT
75Button 7 Multiple OperationFold 22 Bytes9.1 temperature (°C)CRT
75Button 7 Multiple OperationFold 22 Bytes9.4 lux (Lux)CRT
75Button 7 Sequence FunctionFold 21 Bit1.1 switchCRT
75Button 7 Sequence FunctionFold 22 Bit2.1 switch controlCRT
75Button 7 Sequence FunctionFold 21 Byte5.10 counter pulses (0..255)CRT
75Button 7 Sequence FunctionFold 21 Byte5.1 percentage (0..100%)CRT
75Button 7 Sequence FunctionFold 22 Bytes7.1 pulsesCRT
75Button 7 Sequence FunctionFold 22 Bytes9.1 temperature (°C)CRT
75Button 7 Sequence FunctionFold 22 Bytes9.4 lux (Lux)CRT
75Button 7 Counter AlarmAlarm1 Bit1.5 alarmCRT
76Button 7 Long Press StatusStatus1 Bit1.1 switchCRW
77Button 7 Second ObjectSwitching 1Bit1 Bit1.1 switchCRT
77Button 7 Second ObjectSwitching 2Bit2 Bit2.1 switch controlCRT
77Button 7 Second ObjectSwitching 1Byte Value1 Byte5.10 counter pulses (0..255)CRT
77Button 7 Second ObjectSwitching Percent Value1 Byte5.1 percentage (0..100%)CRT
77Button 7 Second ObjectSwitching 2Byte Value2 Bytes7.1 pulsesCRT
77Button 7 Second ObjectTemperature Value2 Bytes9.1 temperature (°C)CRT
77Button 7 Second ObjectLux Value2 Bytes9.4 lux (Lux)CRT
77Button 7 Multiple OperationFold 31 Bit1.1 switchCRT
77Button 7 Multiple OperationFold 32 Bit2.1 switch controlCRT
77Button 7 Multiple OperationFold 31 Byte5.10 counter pulses (0..255)CRT
77Button 7 Multiple OperationFold 31 Byte5.1 percentage (0..100%)CRT
77Button 7 Multiple OperationFold 32 Bytes7.1 pulsesCRT
77Button 7 Multiple OperationFold 32 Bytes9.1 temperature (°C)CRT
77Button 7 Multiple OperationFold 32 Bytes9.4 lux (Lux)CRT
77Button 7 Sequence FunctionFold 31 Bit1.1 switchCRT
77Button 7 Sequence FunctionFold 32 Bit2.1 switch controlCRT
77Button 7 Sequence FunctionFold 31 Byte5.10 counter pulses (0..255)CRT
77Button 7 Sequence FunctionFold 31 Byte5.1 percentage (0..100%)CRT
77Button 7 Sequence FunctionFold 32 Bytes7.1 pulsesCRT
77Button 7 Sequence FunctionFold 32 Bytes9.1 temperature (°C)CRT
77Button 7 Sequence FunctionFold 32 Bytes9.4 lux (Lux)CRT
77Button 7 Counter2Byte Value2 Bytes7.1 pulsesCRWT
78Button 7 Second Object StatusStatus1 Bit1.1 switchCRW
78Button 7 Counter1Byte Value1 Byte5.10 counter pulses (0..255)CRWT
79Button 7 Multiple OperationFold 41 Bit1.1 switchCRT
79Button 7 Multiple OperationFold 42 Bit2.1 switch controlCRT
79Button 7 Multiple OperationFold 41 Byte5.10 counter pulses (0..255)CRT
79Button 7 Multiple OperationFold 41 Byte5.1 percentage (0..100%)CRT
79Button 7 Multiple OperationFold 42 Bytes7.1 pulsesCRT
79Button 7 Multiple OperationFold 42 Bytes9.1 temperature (°C)CRT
79Button 7 Multiple OperationFold 42 Bytes9.4 lux (Lux)CRT
79Button 7 Sequence FunctionFold 41 Bit1.1 switchCRT
79Button 7 Sequence FunctionFold 42 Bit2.1 switch controlCRT
79Button 7 Sequence FunctionFold 41 Byte5.10 counter pulses (0..255)CRT
79Button 7 Sequence FunctionFold 41 Byte5.1 percentage (0..100%)CRT
79Button 7 Sequence FunctionFold 42 Bytes7.1 pulsesCRT
79Button 7 Sequence FunctionFold 42 Bytes9.1 temperature (°C)CRT
79Button 7 Sequence FunctionFold 42 Bytes9.4 lux (Lux)CRT
79Button 7 Counter4Byte Value4 Bytes12.1 counter pulses (unsigned)CRWT
80Button 7 LockLock1 Bit1.3 enableCRW
81Button 7 LED statusStatus1 Bit1.1 switchCRW
84Button 7 Step CountLux Value2 Bytes9.4 lux (Lux)CRWTU
85Button 8 Short PressSwitching 1Bit1 Bit1.1 switchCRT
85Button 8 Short PressSwitching 2Bit2 Bit2.1 switch controlCRT
85Button 8 Short PressSwitching 1Byte Value1 Byte5.10 counter pulses (0..255)CRT
85Button 8 Short PressSwitching Percent Value1 Byte5.1 percentage (0..100%)CRT
85Button 8 Short PressSwitching 2Byte Value2 Bytes7.1 pulsesCRT
85Button 8 Short PressTemperature Value2 Bytes9.1 temperature (°C)CRT
85Button 8 Short PressLux Value2 Bytes9.4 lux (Lux)CRT
85Button 8 DimmingSwitch On Off1 Bit1.1 switchCRT
85Button 8 Blind/ShutterUp/Down1 Bit1.8 up/downCRT
85Button 8 SceneScene Control1 Byte18.1 scene controlCRT
85Button 8 Multiple OperationFold 11 Bit1.1 switchCRT
85Button 8 Multiple OperationFold 12 Bit2.1 switch controlCRT
85Button 8 Multiple OperationFold 11 Byte5.10 counter pulses (0..255)CRT
85Button 8 Multiple OperationFold 11 Byte5.1 percentage (0..100%)CRT
85Button 8 Multiple OperationFold 12 Bytes7.1 pulsesCRT
85Button 8 Multiple OperationFold 12 Bytes9.1 temperature (°C)CRT
85Button 8 Multiple OperationFold 12 Bytes9.4 lux (Lux)CRT
85Button 8 Sequence FunctionFold 11 Bit1.1 switchCRT
85Button 8 Sequence FunctionFold 12 Bit2.1 switch controlCRT
85Button 8 Sequence FunctionFold 11 Byte5.10 counter pulses (0..255)CRT
85Button 8 Sequence FunctionFold 11 Byte5.1 percentage (0..100%)CRT
85Button 8 Sequence FunctionFold 12 Bytes7.1 pulsesCRT
85Button 8 Sequence FunctionFold 12 Bytes9.1 temperature (°C)CRT
85Button 8 Sequence FunctionFold 12 Bytes9.4 lux (Lux)CRT
85Button 8 CounterRequest Value1 Bit1.17 triggerCW
85Button 8 Fan ControlFan Control1 Byte5.10 counter pulses (0..255)CRT
85Button 8 Fan ControlFan Control1 Byte5.1 percentage (0..100%)CRT
85Button 8 Operating ModeOperating Mode1 Byte20.102 HVAC modeCRT
85Button 8 Heat/CoolHeat/Cool1 Bit1.100 cooling/heatingCRT
85Button 8 Step Control1 Byte Value1 Byte5.10 counter pulses (0..255)CRT
85Button 8 Step Control1 Byte Percentage1 Byte5.1 percentage (0..100%)CRT
85Button 8 Step Control2 Byte Value2 Bytes7.1 pulsesCRT
85Button 8 Step ControlTemperature Value2 Bytes9.1 temperature (°C)CRT
85Button 8 Step ControlScene Value1 Byte18.1 scene controlCRT
85Button 8 Step ControlLux Value2 Bytes9.4 lux (Lux)CRT
85Button 8 External SetpointTemperature2 Bytes9.1 temperature (°C)CRT
85Button 8 HVAC ModeHVAC Mode1 Byte20.105 HVAC control modeCRT
86Button 8 Short Press StatusStatus1 Bit1.1 switchCRW
86Button 8 DimmingStatus1 Bit1.1 switchCRW
87Button 8 Long PressSwitching 1Bit1 Bit1.1 switchCRT
87Button 8 Long PressSwitching 2Bit2 Bit2.1 switch controlCRT
87Button 8 Long PressSwitching 1Byte Value1 Byte5.10 counter pulses (0..255)CRT
87Button 8 Long PressSwitching Percent Value1 Byte5.1 percentage (0..100%)CRT
87Button 8 Long PressSwitching 2Byte Value2 Bytes7.1 pulsesCRT
87Button 8 Long PressTemperature Value2 Bytes9.1 temperature (°C)CRT
87Button 8 Long PressLux Value2 Bytes9.4 lux (Lux)CRT
87Button 8 DimmingRelative Dimming4 Bit3.7 dimming controlCRT
87Button 8 Blind/ShutterStep/Stop1 Bit1.7 stepCRT
87Button 8 Multiple OperationFold 21 Bit1.1 switchCRT
87Button 8 Multiple OperationFold 22 Bit2.1 switch controlCRT
87Button 8 Multiple OperationFold 21 Byte5.10 counter pulses (0..255)CRT
87Button 8 Multiple OperationFold 21 Byte5.1 percentage (0..100%)CRT
87Button 8 Multiple OperationFold 22 Bytes7.1 pulsesCRT
87Button 8 Multiple OperationFold 22 Bytes9.1 temperature (°C)CRT
87Button 8 Multiple OperationFold 22 Bytes9.4 lux (Lux)CRT
87Button 8 Sequence FunctionFold 21 Bit1.1 switchCRT
87Button 8 Sequence FunctionFold 22 Bit2.1 switch controlCRT
87Button 8 Sequence FunctionFold 21 Byte5.10 counter pulses (0..255)CRT
87Button 8 Sequence FunctionFold 21 Byte5.1 percentage (0..100%)CRT
87Button 8 Sequence FunctionFold 22 Bytes7.1 pulsesCRT
87Button 8 Sequence FunctionFold 22 Bytes9.1 temperature (°C)CRT
87Button 8 Sequence FunctionFold 22 Bytes9.4 lux (Lux)CRT
87Button 8 Counter AlarmAlarm1 Bit1.5 alarmCRT
88Button 8 Long Press StatusStatus1 Bit1.1 switchCRW
89Button 8 Second ObjectSwitching 1Bit1 Bit1.1 switchCRT
89Button 8 Second ObjectSwitching 2Bit2 Bit2.1 switch controlCRT
89Button 8 Second ObjectSwitching 1Byte Value1 Byte5.10 counter pulses (0..255)CRT
89Button 8 Second ObjectSwitching Percent Value1 Byte5.1 percentage (0..100%)CRT
89Button 8 Second ObjectSwitching 2Byte Value2 Bytes7.1 pulsesCRT
89Button 8 Second ObjectTemperature Value2 Bytes9.1 temperature (°C)CRT
89Button 8 Second ObjectLux Value2 Bytes9.4 lux (Lux)CRT
89Button 8 Multiple OperationFold 31 Bit1.1 switchCRT
89Button 8 Multiple OperationFold 32 Bit2.1 switch controlCRT
89Button 8 Multiple OperationFold 31 Byte5.10 counter pulses (0..255)CRT
89Button 8 Multiple OperationFold 31 Byte5.1 percentage (0..100%)CRT
89Button 8 Multiple OperationFold 32 Bytes7.1 pulsesCRT
89Button 8 Multiple OperationFold 32 Bytes9.1 temperature (°C)CRT
89Button 8 Multiple OperationFold 32 Bytes9.4 lux (Lux)CRT
89Button 8 Sequence FunctionFold 31 Bit1.1 switchCRT
89Button 8 Sequence FunctionFold 32 Bit2.1 switch controlCRT
89Button 8 Sequence FunctionFold 31 Byte5.10 counter pulses (0..255)CRT
89Button 8 Sequence FunctionFold 31 Byte5.1 percentage (0..100%)CRT
89Button 8 Sequence FunctionFold 32 Bytes7.1 pulsesCRT
89Button 8 Sequence FunctionFold 32 Bytes9.1 temperature (°C)CRT
89Button 8 Sequence FunctionFold 32 Bytes9.4 lux (Lux)CRT
89Button 8 Counter2Byte Value2 Bytes7.1 pulsesCRWT
90Button 8 Second Object StatusStatus1 Bit1.1 switchCRW
90Button 8 Counter1Byte Value1 Byte5.10 counter pulses (0..255)CRWT
91Button 8 Multiple OperationFold 41 Bit1.1 switchCRT
91Button 8 Multiple OperationFold 42 Bit2.1 switch controlCRT
91Button 8 Multiple OperationFold 41 Byte5.10 counter pulses (0..255)CRT
91Button 8 Multiple OperationFold 41 Byte5.1 percentage (0..100%)CRT
91Button 8 Multiple OperationFold 42 Bytes7.1 pulsesCRT
91Button 8 Multiple OperationFold 42 Bytes9.1 temperature (°C)CRT
91Button 8 Multiple OperationFold 42 Bytes9.4 lux (Lux)CRT
91Button 8 Sequence FunctionFold 41 Bit1.1 switchCRT
91Button 8 Sequence FunctionFold 42 Bit2.1 switch controlCRT
91Button 8 Sequence FunctionFold 41 Byte5.10 counter pulses (0..255)CRT
91Button 8 Sequence FunctionFold 41 Byte5.1 percentage (0..100%)CRT
91Button 8 Sequence FunctionFold 42 Bytes7.1 pulsesCRT
91Button 8 Sequence FunctionFold 42 Bytes9.1 temperature (°C)CRT
91Button 8 Sequence FunctionFold 42 Bytes9.4 lux (Lux)CRT
91Button 8 Counter4Byte Value4 Bytes12.1 counter pulses (unsigned)CRWT
92Button 8 LockLock1 Bit1.3 enableCRW
93Button 8 LED statusStatus1 Bit1.1 switchCRW
96Button 8 Step CountLux Value2 Bytes9.4 lux (Lux)CRWTU
97LCD Left Upper Button SwitchingSwitching1 Bit1.1 switchCT
97LCD Left Upper Button Heat/CoolHeating/Cooling1 Bit1.100 cooling/heatingCT
97LCD Left Upper Button Fan Value1 Byte Value1 Byte5.10 counter pulses (0..255)CT
97LCD Left Upper Button Fan Value1 Byte Percentage1 Byte5.1 percentage (0..100%)CT
97LCD Left Upper HVAC ModeHVAC Mode1 Byte20.105 HVAC control modeCRT
97Button 9 Short PressSwitching 1Bit1 Bit1.1 switchCRT
97Button 9 Short PressSwitching 2Bit2 Bit2.1 switch controlCRT
97Button 9 Short PressSwitching 1Byte Value1 Byte5.10 counter pulses (0..255)CRT
97Button 9 Short PressSwitching Percent Value1 Byte5.1 percentage (0..100%)CRT
97Button 9 Short PressSwitching 2Byte Value2 Bytes7.1 pulsesCRT
97Button 9 Short PressTemperature Value2 Bytes9.1 temperature (°C)CRT
97Button 9 Short PressLux Value2 Bytes9.4 lux (Lux)CRT
97Button 9 DimmingSwitch On Off1 Bit1.1 switchCRT
97Button 9 Blind/ShutterUp/Down1 Bit1.8 up/downCRT
97Button 9 SceneScene Control1 Byte18.1 scene controlCRT
97Button 9 Multiple OperationFold 11 Bit1.1 switchCRT
97Button 9 Multiple OperationFold 12 Bit2.1 switch controlCRT
97Button 9 Multiple OperationFold 11 Byte5.10 counter pulses (0..255)CRT
97Button 9 Multiple OperationFold 11 Byte5.1 percentage (0..100%)CRT
97Button 9 Multiple OperationFold 12 Bytes7.1 pulsesCRT
97Button 9 Multiple OperationFold 12 Bytes9.1 temperature (°C)CRT
97Button 9 Multiple OperationFold 12 Bytes9.4 lux (Lux)CRT
97Button 9 Sequence FunctionFold 11 Bit1.1 switchCRT
97Button 9 Sequence FunctionFold 12 Bit2.1 switch controlCRT
97Button 9 Sequence FunctionFold 11 Byte5.10 counter pulses (0..255)CRT
97Button 9 Sequence FunctionFold 11 Byte5.1 percentage (0..100%)CRT
97Button 9 Sequence FunctionFold 12 Bytes7.1 pulsesCRT
97Button 9 Sequence FunctionFold 12 Bytes9.1 temperature (°C)CRT
97Button 9 Sequence FunctionFold 12 Bytes9.4 lux (Lux)CRT
97Button 9 CounterRequest Value1 Bit1.17 triggerCW
97Button 9 Fan ControlFan Control1 Byte5.10 counter pulses (0..255)CRT
97Button 9 Fan ControlFan Control1 Byte5.1 percentage (0..100%)CRT
97Button 9 Operating ModeOperating Mode1 Byte20.102 HVAC modeCRT
97Button 9 Heat/CoolHeat/Cool1 Bit1.100 cooling/heatingCRT
97Button 9 Step Control1 Byte Value1 Byte5.10 counter pulses (0..255)CRT
97Button 9 Step Control1 Byte Percentage1 Byte5.1 percentage (0..100%)CRT
97Button 9 Step Control2 Byte Value2 Bytes7.1 pulsesCRT
97Button 9 Step ControlTemperature Value2 Bytes9.1 temperature (°C)CRT
97Button 9 Step ControlScene Value1 Byte18.1 scene controlCRT
97Button 9 Step ControlLux Value2 Bytes9.4 lux (Lux)CRT
97Button 9 External SetpointTemperature2 Bytes9.1 temperature (°C)CRT
97Button 9 HVAC ModeHVAC Mode1 Byte20.105 HVAC control modeCRT
98Button 9 Short Press StatusStatus1 Bit1.1 switchCRW
98Button 9 DimmingStatus1 Bit1.1 switchCRW
99Button 9 Long PressSwitching 1Bit1 Bit1.1 switchCRT
99Button 9 Long PressSwitching 2Bit2 Bit2.1 switch controlCRT
99Button 9 Long PressSwitching 1Byte Value1 Byte5.10 counter pulses (0..255)CRT
99Button 9 Long PressSwitching Percent Value1 Byte5.1 percentage (0..100%)CRT
99Button 9 Long PressSwitching 2Byte Value2 Bytes7.1 pulsesCRT
99Button 9 Long PressTemperature Value2 Bytes9.1 temperature (°C)CRT
99Button 9 Long PressLux Value2 Bytes9.4 lux (Lux)CRT
99Button 9 DimmingRelative Dimming4 Bit3.7 dimming controlCRT
99Button 9 Blind/ShutterStep/Stop1 Bit1.7 stepCRT
99Button 9 Multiple OperationFold 21 Bit1.1 switchCRT
99Button 9 Multiple OperationFold 22 Bit2.1 switch controlCRT
99Button 9 Multiple OperationFold 21 Byte5.10 counter pulses (0..255)CRT
99Button 9 Multiple OperationFold 21 Byte5.1 percentage (0..100%)CRT
99Button 9 Multiple OperationFold 22 Bytes7.1 pulsesCRT
99Button 9 Multiple OperationFold 22 Bytes9.1 temperature (°C)CRT
99Button 9 Multiple OperationFold 22 Bytes9.4 lux (Lux)CRT
99Button 9 Sequence FunctionFold 21 Bit1.1 switchCRT
99Button 9 Sequence FunctionFold 22 Bit2.1 switch controlCRT
99Button 9 Sequence FunctionFold 21 Byte5.10 counter pulses (0..255)CRT
99Button 9 Sequence FunctionFold 21 Byte5.1 percentage (0..100%)CRT
99Button 9 Sequence FunctionFold 22 Bytes7.1 pulsesCRT
99Button 9 Sequence FunctionFold 22 Bytes9.1 temperature (°C)CRT
99Button 9 Sequence FunctionFold 22 Bytes9.4 lux (Lux)CRT
99Button 9 Counter AlarmAlarm1 Bit1.5 alarmCRT
100Button 9 Long Press StatusStatus1 Bit1.1 switchCRW
101Button 9 Second ObjectSwitching 1Bit1 Bit1.1 switchCRT
101Button 9 Second ObjectSwitching 2Bit2 Bit2.1 switch controlCRT
101Button 9 Second ObjectSwitching 1Byte Value1 Byte5.10 counter pulses (0..255)CRT
101Button 9 Second ObjectSwitching Percent Value1 Byte5.1 percentage (0..100%)CRT
101Button 9 Second ObjectSwitching 2Byte Value2 Bytes7.1 pulsesCRT
101Button 9 Second ObjectTemperature Value2 Bytes9.1 temperature (°C)CRT
101Button 9 Second ObjectLux Value2 Bytes9.4 lux (Lux)CRT
101Button 9 Multiple OperationFold 31 Bit1.1 switchCRT
101Button 9 Multiple OperationFold 32 Bit2.1 switch controlCRT
101Button 9 Multiple OperationFold 31 Byte5.10 counter pulses (0..255)CRT
101Button 9 Multiple OperationFold 31 Byte5.1 percentage (0..100%)CRT
101Button 9 Multiple OperationFold 32 Bytes7.1 pulsesCRT
101Button 9 Multiple OperationFold 32 Bytes9.1 temperature (°C)CRT
101Button 9 Multiple OperationFold 32 Bytes9.4 lux (Lux)CRT
101Button 9 Sequence FunctionFold 31 Bit1.1 switchCRT
101Button 9 Sequence FunctionFold 32 Bit2.1 switch controlCRT
101Button 9 Sequence FunctionFold 31 Byte5.10 counter pulses (0..255)CRT
101Button 9 Sequence FunctionFold 31 Byte5.1 percentage (0..100%)CRT
101Button 9 Sequence FunctionFold 32 Bytes7.1 pulsesCRT
101Button 9 Sequence FunctionFold 32 Bytes9.1 temperature (°C)CRT
101Button 9 Sequence FunctionFold 32 Bytes9.4 lux (Lux)CRT
101Button 9 Counter2Byte Value2 Bytes7.1 pulsesCRWT
102Button 9 Second Object StatusStatus1 Bit1.1 switchCRW
102Button 9 Counter1Byte Value1 Byte5.10 counter pulses (0..255)CRWT
103Button 9 Multiple OperationFold 41 Bit1.1 switchCRT
103Button 9 Multiple OperationFold 42 Bit2.1 switch controlCRT
103Button 9 Multiple OperationFold 41 Byte5.10 counter pulses (0..255)CRT
103Button 9 Multiple OperationFold 41 Byte5.1 percentage (0..100%)CRT
103Button 9 Multiple OperationFold 42 Bytes7.1 pulsesCRT
103Button 9 Multiple OperationFold 42 Bytes9.1 temperature (°C)CRT
103Button 9 Multiple OperationFold 42 Bytes9.4 lux (Lux)CRT
103Button 9 Sequence FunctionFold 41 Bit1.1 switchCRT
103Button 9 Sequence FunctionFold 42 Bit2.1 switch controlCRT
103Button 9 Sequence FunctionFold 41 Byte5.10 counter pulses (0..255)CRT
103Button 9 Sequence FunctionFold 41 Byte5.1 percentage (0..100%)CRT
103Button 9 Sequence FunctionFold 42 Bytes7.1 pulsesCRT
103Button 9 Sequence FunctionFold 42 Bytes9.1 temperature (°C)CRT
103Button 9 Sequence FunctionFold 42 Bytes9.4 lux (Lux)CRT
103Button 9 Counter4Byte Value4 Bytes12.1 counter pulses (unsigned)CRWT
104Button 9 LockLock1 Bit1.3 enableCRW
105Button 9 LED statusStatus1 Bit1.1 switchCRW
108Button 9 Step CountLux Value2 Bytes9.4 lux (Lux)CRWTU
109Button 10 Short PressSwitching 1Bit1 Bit1.1 switchCRT
109Button 10 Short PressSwitching 2Bit2 Bit2.1 switch controlCRT
109Button 10 Short PressSwitching 1Byte Value1 Byte5.10 counter pulses (0..255)CRT
109Button 10 Short PressSwitching Percent Value1 Byte5.1 percentage (0..100%)CRT
109Button 10 Short PressSwitching 2Byte Value2 Bytes7.1 pulsesCRT
109Button 10 Short PressTemperature Value2 Bytes9.1 temperature (°C)CRT
109Button 10 Short PressLux Value2 Bytes9.4 lux (Lux)CRT
109Button 10 DimmingSwitch On Off1 Bit1.1 switchCRT
109Button 10 Blind/ShutterUp/Down1 Bit1.8 up/downCRT
109Button 10 SceneScene Control1 Byte18.1 scene controlCRT
109Button 10 Multiple OperationFold 11 Bit1.1 switchCRT
109Button 10 Multiple OperationFold 12 Bit2.1 switch controlCRT
109Button 10 Multiple OperationFold 11 Byte5.10 counter pulses (0..255)CRT
109Button 10 Multiple OperationFold 11 Byte5.1 percentage (0..100%)CRT
109Button 10 Multiple OperationFold 12 Bytes7.1 pulsesCRT
109Button 10 Multiple OperationFold 12 Bytes9.1 temperature (°C)CRT
109Button 10 Multiple OperationFold 12 Bytes9.4 lux (Lux)CRT
109Button 10 Sequence FunctionFold 11 Bit1.1 switchCRT
109Button 10 Sequence FunctionFold 12 Bit2.1 switch controlCRT
109Button 10 Sequence FunctionFold 11 Byte5.10 counter pulses (0..255)CRT
109Button 10 Sequence FunctionFold 11 Byte5.1 percentage (0..100%)CRT
109Button 10 Sequence FunctionFold 12 Bytes7.1 pulsesCRT
109Button 10 Sequence FunctionFold 12 Bytes9.1 temperature (°C)CRT
109Button 10 Sequence FunctionFold 12 Bytes9.4 lux (Lux)CRT
109Button 10 CounterRequest Value1 Bit1.17 triggerCW
109Button 10 Fan ControlFan Control1 Byte5.10 counter pulses (0..255)CRT
109Button 10 Fan ControlFan Control1 Byte5.1 percentage (0..100%)CRT
109Button 10 Operating ModeOperating Mode1 Byte20.102 HVAC modeCRT
109Button 10 Heat/CoolHeat/Cool1 Bit1.100 cooling/heatingCRT
109Button 10 Step Control1 Byte Value1 Byte5.10 counter pulses (0..255)CRT
109Button 10 Step Control1 Byte Percentage1 Byte5.1 percentage (0..100%)CRT
109Button 10 Step Control2 Byte Value2 Bytes7.1 pulsesCRT
109Button 10 Step ControlTemperature Value2 Bytes9.1 temperature (°C)CRT
109Button 10 Step ControlScene Value1 Byte18.1 scene controlCRT
109Button 10 Step ControlLux Value2 Bytes9.4 lux (Lux)CRT
109Button 10 External SetpointTemperature2 Bytes9.1 temperature (°C)CRT

First 1000 of 1656 group objects shown. Download the .knxprod for the full list.

Parameters (954)
ParameterTypeDefault
input_prmt_channel_glbl_param_14_10unsignedInt 0…655350
input_prmt_channel_glbl_param_25_10unsignedInt 0…655350
input_prmt_channel_glbl_param_15_11unsignedInt 0…655350
input_prmt_channel_glbl_param_26_11unsignedInt 0…655350
Switching typelist1Bit
input_prmt_channel_glbl_param_1_1unsignedInt 0…655350
logic_prmt_channel_glbl_param_8_2unsignedInt 0…2550
logic_prmt_channel_glbl_param_7_3unsignedInt 0…2550
logic_prmt_channel_glbl_param_6_4unsignedInt 0…2550
left_upper_button_opmodeunsignedInt 0…2550
Output typelist1Bit
conv_prmt_channel_glbl_param_3_1unsignedInt 0…655350
conv_prmt_channel_glbl_param_2_2unsignedInt 0…655350
conv_prmt_channel_glbl_param_1_3unsignedInt 0…655350
--> 1bit shifting steplist0.1K
backup_22unsignedInt 0…655350
backup_33unsignedInt 0…655350
backup_44unsignedInt 0…655350
backup_55unsignedInt 0…655350
Temperature offset for enable additinonal systemlist2.0K
Setpoints for operating modeslistIndividual
LCD backlight timer time (sec.)unsignedInt 0…2555
--> LEDs brigthness (%)unsignedInt 0…100100
Additional cooling control typelistContinuous
Feedback for fan level 1Byte objectlist1 Byte Percent
avg_prmt_channel_glbl_param_8_2unsignedInt 0…655350
avg_prmt_channel_glbl_param_7_3unsignedInt 0…655350
avg_prmt_channel_glbl_param_6_4unsignedInt 0…655350
Enable additional cooling systemlistDisable
right_lower_button_setpointunsignedInt 0…2550
Show humidity on LCDlistYES
Setpoint setting interval adjustment decreaselist6.0 °C
Minimum oscillation for sending lux valuelist10
LCD illimunation object typelist1 Byte (%)
left_upper_button_functionunsignedInt 0…2550
input_prmt_channel_glbl_param_19_4unsignedInt 0…655350
input_prmt_channel_glbl_param_18_5unsignedInt 0…655350
input_prmt_channel_glbl_param_29_5unsignedInt 0…655350
input_prmt_channel_glbl_param_17_6unsignedInt 0…655350
input_prmt_channel_glbl_param_28_6unsignedInt 0…655350
input_prmt_channel_glbl_param_16_7unsignedInt 0…655350
input_prmt_channel_glbl_param_27_7unsignedInt 0…655350
input_prmt_channel_glbl_param_15_8unsignedInt 0…655350
input_prmt_channel_glbl_param_26_8unsignedInt 0…655350
input_prmt_channel_glbl_param_14_9unsignedInt 0…655350
input_prmt_channel_glbl_param_25_9unsignedInt 0…655350
Use device alarm for failurelistDisable
Send additional cooling command value periodically (sec)unsignedInt 0…2555
input_prmt_channel_glbl_param_13_10unsignedInt 0…655350
input_prmt_channel_glbl_param_24_10unsignedInt 0…655350
input_prmt_channel_glbl_param_35_10unsignedInt 0…655350
input_prmt_channel_glbl_param_14_11unsignedInt 0…655350
input_prmt_channel_glbl_param_25_11unsignedInt 0…655350
Fan level 1Bit valuelistToggle
input_prmt_channel_glbl_param_2_1unsignedInt 0…655350
input_prmt_channel_glbl_param_1_2unsignedInt 0…655350
logic_prmt_channel_glbl_param_8_3unsignedInt 0…2550
logic_prmt_channel_glbl_param_7_4unsignedInt 0…2550
Fan level individual objectslistEnable
conv_prmt_channel_glbl_param_5_0unsignedInt 0…655350
conv_prmt_channel_glbl_param_4_1unsignedInt 0…655350
conv_prmt_channel_glbl_param_3_2unsignedInt 0…655350
conv_prmt_channel_glbl_param_2_3unsignedInt 0…655350
Send dimming value cycle (msec.)unsignedInt 500…65535500
backup_23unsignedInt 0…655350
backup_34unsignedInt 0…655350
backup_45unsignedInt 0…655350
backup_56unsignedInt 0…655350
PWM total time (min)unsignedInt 5…25515
avg_prmt_channel_glbl_param_8_3unsignedInt 0…655350
avg_prmt_channel_glbl_param_7_4unsignedInt 0…655350
right_upper_button_setpoint_stepunsignedInt 0…2550
Presetting setpoint shiftinglistDisable
right_upper_button_opmodeunsignedInt 0…2550
Send temperature value periodicallylistDisable
input_prmt_channel_glbl_param_19_5unsignedInt 0…655350
input_prmt_channel_glbl_param_18_6unsignedInt 0…655350
input_prmt_channel_glbl_param_29_6unsignedInt 0…655350
input_prmt_channel_glbl_param_17_7unsignedInt 0…655350
input_prmt_channel_glbl_param_28_7unsignedInt 0…655350
input_prmt_channel_glbl_param_16_8unsignedInt 0…655350
input_prmt_channel_glbl_param_27_8unsignedInt 0…655350
input_prmt_channel_glbl_param_15_9unsignedInt 0…655350
input_prmt_channel_glbl_param_26_9unsignedInt 0…655350
Internal threshold 1listDisable
Status LEDs intensitylistVia parameter
Fan 1 lower limit (%)unsignedInt 0…10010
-> Sending interval for temperature (sec)unsignedInt 0…25510
input_prmt_channel_glbl_param_12_10unsignedInt 0…655350
input_prmt_channel_glbl_param_23_10unsignedInt 0…655350
input_prmt_channel_glbl_param_34_10unsignedInt 0…655350
input_prmt_channel_glbl_param_13_11unsignedInt 0…655350
input_prmt_channel_glbl_param_24_11unsignedInt 0…655350
input_prmt_channel_glbl_param_35_11unsignedInt 0…655350
Short press contact typelistOn Press
input_prmt_channel_glbl_param_3_1unsignedInt 0…655350
input_prmt_channel_glbl_param_2_2unsignedInt 0…655350
input_prmt_channel_glbl_param_1_3unsignedInt 0…655350
logic_prmt_channel_glbl_param_8_4unsignedInt 0…2550
Fan level 1Byte object typelist1 Byte Percent
conv_prmt_channel_glbl_param_6_0unsignedInt 0…655350
conv_prmt_channel_glbl_param_5_1unsignedInt 0…655350
conv_prmt_channel_glbl_param_4_2unsignedInt 0…655350
conv_prmt_channel_glbl_param_3_3unsignedInt 0…655350
Additional heating maximum control value (%)unsignedInt 0…100100
Close heat & cool icon when actuating value is "0"listNO
backup_24unsignedInt 0…655350
backup_35unsignedInt 0…655350
backup_46unsignedInt 0…655350
backup_57unsignedInt 0…655350
Additional heating control typelistContinuous
Setpoint after bus voltage recoverylistPrevious value
LCD intensity when system is OFF (%)list10 %
Minimum control value (%)unsignedInt 0…1000
avg_prmt_channel_glbl_param_8_4unsignedInt 0…655350
Enable additional heating systemlistDisable
Lower limit 1(˚C)list0 °C
--> Setpoint shifting steplist0.1K
left_upper_button_setpointunsignedInt 0…2550
input_prmt_channel_glbl_param_30_0unsignedInt 0…655350
input_prmt_channel_glbl_param_19_6unsignedInt 0…655350
input_prmt_channel_glbl_param_18_7unsignedInt 0…655350
input_prmt_channel_glbl_param_29_7unsignedInt 0…655350
input_prmt_channel_glbl_param_17_8unsignedInt 0…655350
input_prmt_channel_glbl_param_28_8unsignedInt 0…655350
input_prmt_channel_glbl_param_16_9unsignedInt 0…655350
input_prmt_channel_glbl_param_27_9unsignedInt 0…655350
Internal threshold 2listDisable
Fan 2 lower limit (%)unsignedInt 0…10020
Fan 3 lower limit (%)unsignedInt 0…10040
Distinction between long and short operationlistNO
input_prmt_channel_glbl_param_4_1unsignedInt 0…655350
input_prmt_channel_glbl_param_3_2unsignedInt 0…655350
input_prmt_channel_glbl_param_2_3unsignedInt 0…655350
input_prmt_channel_glbl_param_1_4unsignedInt 0…655350
Cooling dependant standby setpointlist-4.0 °C
conv_prmt_channel_glbl_param_6_1unsignedInt 0…655350
conv_prmt_channel_glbl_param_5_2unsignedInt 0…655350
conv_prmt_channel_glbl_param_4_3unsignedInt 0…655350
Send heating/cooling mode feedbacklistYES
Auto fan levels limits temperature difference ( °C)list1.0 °C
backup_25unsignedInt 0…655350
backup_36unsignedInt 0…655350
backup_47unsignedInt 0…655350
backup_58unsignedInt 0…655350
Ambient lower limit 1list5
Lower limit 2(˚C)list0 °C
--> Shifting lower limitsignedInt -128…0-32
Setpoint setting interval adjustment increaselist10.0 °C
LCD illimunationlistAlways on
Dimming step value (%)unsignedInt 0…10010
input_prmt_channel_glbl_param_20_0unsignedInt 0…655351
input_prmt_channel_glbl_param_31_0unsignedInt 0…655350
input_prmt_channel_glbl_param_30_1unsignedInt 0…655350
input_prmt_channel_glbl_param_19_7unsignedInt 0…655350
input_prmt_channel_glbl_param_18_8unsignedInt 0…655350
input_prmt_channel_glbl_param_29_8unsignedInt 0…655350
input_prmt_channel_glbl_param_17_9unsignedInt 0…655350
input_prmt_channel_glbl_param_28_9unsignedInt 0…655350
Internal threshold 3listDisable
Command value objectlist2 seperated object
Integral time (min)unsignedInt 0…255100
Fan 4 lower limit (%)unsignedInt 0…10060
input_prmt_channel_glbl_param_11_10unsignedInt 0…655350
input_prmt_channel_glbl_param_22_10unsignedInt 0…655350
input_prmt_channel_glbl_param_33_10unsignedInt 0…655350
input_prmt_channel_glbl_param_12_11unsignedInt 0…655350
input_prmt_channel_glbl_param_23_11unsignedInt 0…655350
input_prmt_channel_glbl_param_34_11unsignedInt 0…655350
conv_prmt_channel_glbl_param_6_2unsignedInt 0…655350
conv_prmt_channel_glbl_param_5_3unsignedInt 0…655350
Type of additinal heating systemlistWarm water heating
backup_15unsignedInt 0…655350
backup_26unsignedInt 0…655350
backup_37unsignedInt 0…655350
backup_48unsignedInt 0…655350
backup_59unsignedInt 0…655350
Temperature sensor for room controllerlistInternal
-> Internal sensor calibrationlist0 °C
Maximum control value (%)unsignedInt 0…100100
Humidity lower limit 1unsignedInt 0…10010
Ambient lower limit 2list20
Feedback for fan level individual objectslistEnable
Lower limit 3(˚C)list0 °C
right_lower_button_fan_stepunsignedInt 0…2550
--> Shifting upper liimitsignedInt 0…12732
Cooling control typelistContinuous
--> Period of sending humidity value (sec)unsignedInt 0…2555
Minimum dimming value (%)unsignedInt 0…1000
input_prmt_channel_glbl_param_10_0listToggle
Pulse detection onlistClosing contact
input_prmt_channel_glbl_param_32_0unsignedInt 0…655350
input_prmt_channel_glbl_param_20_1unsignedInt 0…655350
input_prmt_channel_glbl_param_31_1unsignedInt 0…655350
input_prmt_channel_glbl_param_30_2unsignedInt 0…655350
input_prmt_channel_glbl_param_19_8unsignedInt 0…655350
input_prmt_channel_glbl_param_18_9unsignedInt 0…655350
input_prmt_channel_glbl_param_29_9unsignedInt 0…655350
input_prmt_channel_glbl_param_9_10unsignedInt 0…655350
LCD backlight intensity (%)unsignedInt 0…100100
Fan 5 lower limit (%)unsignedInt 0…10080
RS485 ID NumberunsignedInt 1…2543
input_prmt_channel_glbl_param_10_10unsignedInt 0…655350
input_prmt_channel_glbl_param_21_10unsignedInt 0…655350
input_prmt_channel_glbl_param_32_10unsignedInt 0…655350
input_prmt_channel_glbl_param_11_11unsignedInt 0…655350
input_prmt_channel_glbl_param_22_11unsignedInt 0…655350
input_prmt_channel_glbl_param_33_11unsignedInt 0…655350
Long press switching typelist1Bit
input_prmt_channel_glbl_param_5_1unsignedInt 0…655350
input_prmt_channel_glbl_param_4_2unsignedInt 0…655350
input_prmt_channel_glbl_param_3_3unsignedInt 0…655350
input_prmt_channel_glbl_param_2_4unsignedInt 0…655350
input_prmt_channel_glbl_param_1_5unsignedInt 0…655350
Output value when logic true (2Byte)unsignedInt 0…65535500
Buttons lock control (LCD buttons including)listNO
Cooling dependant night setpointlist-2.0 °C
Humidity lower limit 2unsignedInt 0…10011
Ambient lower limit 3list30
right_lower_button_setpoint_stepunsignedInt 0…2550
Send operating mode feedbacklistYES
Maximum dimming value (%)unsignedInt 0…100100
Sending second objectlistNO
Second object lux valuelist50 lux
input_prmt_channel_glbl_param_33_0unsignedInt 0…655350
input_prmt_channel_glbl_param_10_1unsignedInt 0…655350
input_prmt_channel_glbl_param_21_1unsignedInt 0…655350
input_prmt_channel_glbl_param_32_1unsignedInt 0…655350
input_prmt_channel_glbl_param_20_2unsignedInt 0…655350
input_prmt_channel_glbl_param_31_2unsignedInt 0…655350
input_prmt_channel_glbl_param_30_3unsignedInt 0…655350
input_prmt_channel_glbl_param_19_9unsignedInt 0…655350
input_prmt_channel_glbl_param_8_10unsignedInt 0…655350
input_prmt_channel_glbl_param_9_11unsignedInt 0…655350
fan_level_up_downunsignedInt 0…2550
input_prmt_channel_glbl_param_20_10unsignedInt 0…655350
input_prmt_channel_glbl_param_31_10unsignedInt 0…655350
input_prmt_channel_glbl_param_10_11unsignedInt 0…655350
input_prmt_channel_glbl_param_21_11unsignedInt 0…655350
input_prmt_channel_glbl_param_32_11unsignedInt 0…655350
Long press after (ms)unsignedInt 300…10000500
input_prmt_channel_glbl_param_6_1unsignedInt 0…655350
input_prmt_channel_glbl_param_5_2unsignedInt 0…655350
input_prmt_channel_glbl_param_4_3unsignedInt 0…655350
input_prmt_channel_glbl_param_3_4unsignedInt 0…655350
input_prmt_channel_glbl_param_2_5unsignedInt 0…655350
input_prmt_channel_glbl_param_1_6unsignedInt 0…655350
Output value when logic false (2Byte)unsignedInt 0…655351000
logic_prmt_channel_glbl_param_4_1unsignedInt 0…655350
Setpoint heat protectionlist40.0 °C
Feedback for auto/manual control objectlist1:Manual / 0:Auto
conv_prmt_channel_glbl_param_6_3unsignedInt 0…655350
backup_16unsignedInt 0…655350
backup_27unsignedInt 0…655350
backup_38unsignedInt 0…655350
backup_49unsignedInt 0…655350
Send cooling command value periodically (sec)unsignedInt 0…25510
Heating dependant night setpointlist3.0 °C
Humidity lower limit 3unsignedInt 0…10015
--> In operation sending time (sec.)unsignedInt 0…655355
left_lower_button_functionunsignedInt 0…2550
left_upper_button_fan_stepunsignedInt 0…2550
Hysteresis 2 pointslist1.0K
Setpoint interval for heat/cool deadbandlist2.0 °C
Minimum oscillation value for sending humidity valuelist1
Lock function usagelistNo lock function
Long press lux valuelist50 lux
input_prmt_channel_glbl_param_34_0unsignedInt 0…655350
input_prmt_channel_glbl_param_11_1unsignedInt 0…655350
input_prmt_channel_glbl_param_22_1unsignedInt 0…655350
input_prmt_channel_glbl_param_33_1unsignedInt 0…655350
input_prmt_channel_glbl_param_10_2unsignedInt 0…655350
input_prmt_channel_glbl_param_21_2unsignedInt 0…655350
input_prmt_channel_glbl_param_32_2unsignedInt 0…655350
input_prmt_channel_glbl_param_20_3unsignedInt 0…655350
input_prmt_channel_glbl_param_31_3unsignedInt 0…655350
input_prmt_channel_glbl_param_30_4unsignedInt 0…655350
input_prmt_channel_glbl_param_7_10unsignedInt 0…655350
input_prmt_channel_glbl_param_8_11unsignedInt 0…655350
Use room controller functionslistEnable
right_upper_button_opmode_stepunsignedInt 0…2550
PWM data typelist1 Bit
left_lower_button_fanunsignedInt 0…2550
input_prmt_channel_glbl_param_30_10unsignedInt 0…655350
input_prmt_channel_glbl_param_20_11unsignedInt 0…655350
input_prmt_channel_glbl_param_31_11unsignedInt 0…655350
Send object value after bus voltage recoverylistNO
input_prmt_channel_glbl_param_7_1unsignedInt 0…655350
input_prmt_channel_glbl_param_6_2unsignedInt 0…655350
input_prmt_channel_glbl_param_5_3unsignedInt 0…655350
input_prmt_channel_glbl_param_4_4unsignedInt 0…655350
input_prmt_channel_glbl_param_3_5unsignedInt 0…655350
input_prmt_channel_glbl_param_2_6unsignedInt 0…655350
input_prmt_channel_glbl_param_1_7unsignedInt 0…655350
logic_prmt_channel_glbl_param_5_1unsignedInt 0…655350
logic_prmt_channel_glbl_param_4_2unsignedInt 0…655350
Heating dependant standby setpointlist4.0 °C
backup_17unsignedInt 0…655350
backup_28unsignedInt 0…655350
backup_39unsignedInt 0…655350
Weighting factorlist50% / 50%
Maximum lux value of area (lux)unsignedInt 0…65535500
Room controller mode after bus recoverylistPrevious value
Second object contact typelistOn Press
input_prmt_channel_glbl_param_24_0list50 lux
input_prmt_channel_glbl_param_35_0unsignedInt 0…655350
input_prmt_channel_glbl_param_12_1unsignedInt 0…655350
input_prmt_channel_glbl_param_23_1unsignedInt 0…655350
input_prmt_channel_glbl_param_34_1unsignedInt 0…655350
input_prmt_channel_glbl_param_11_2unsignedInt 0…655350
input_prmt_channel_glbl_param_22_2unsignedInt 0…655350
input_prmt_channel_glbl_param_33_2unsignedInt 0…655350
input_prmt_channel_glbl_param_10_3unsignedInt 0…655350
input_prmt_channel_glbl_param_21_3unsignedInt 0…655350
input_prmt_channel_glbl_param_32_3unsignedInt 0…655350
input_prmt_channel_glbl_param_20_4unsignedInt 0…655350
input_prmt_channel_glbl_param_31_4unsignedInt 0…655350
input_prmt_channel_glbl_param_30_5unsignedInt 0…655350
input_prmt_channel_glbl_param_6_10unsignedInt 0…655350
input_prmt_channel_glbl_param_7_11unsignedInt 0…655350
input_prmt_channel_glbl_param_30_11unsignedInt 0…655350
Additional heating proportional band (K)list5.0K
Second object switching typelist1Bit
input_prmt_channel_glbl_param_8_1unsignedInt 0…655350
input_prmt_channel_glbl_param_7_2unsignedInt 0…655350
input_prmt_channel_glbl_param_6_3unsignedInt 0…655350
input_prmt_channel_glbl_param_5_4unsignedInt 0…655350
input_prmt_channel_glbl_param_4_5unsignedInt 0…655350
input_prmt_channel_glbl_param_3_6unsignedInt 0…655350
input_prmt_channel_glbl_param_2_7unsignedInt 0…655350
Left upper button functionlistFan control
logic_prmt_channel_glbl_param_5_2unsignedInt 0…655350
logic_prmt_channel_glbl_param_4_3unsignedInt 0…655350
Cooling dependant comfort setpointlist-5.0 °C
backup_18unsignedInt 0…655350
backup_29unsignedInt 0…655350
LCD backlight intensity after timer (%)unsignedInt 0…10020
Average input quantitylist5 Input
left_lower_button_setpointunsignedInt 0…2550
Long press contact typelistOn Press
LED configurationlistLed status object
input_prmt_channel_glbl_param_13_1unsignedInt 0…655350
input_prmt_channel_glbl_param_24_1unsignedInt 0…655350
input_prmt_channel_glbl_param_35_1unsignedInt 0…655350
input_prmt_channel_glbl_param_12_2unsignedInt 0…655350
input_prmt_channel_glbl_param_23_2unsignedInt 0…655350
input_prmt_channel_glbl_param_34_2unsignedInt 0…655350
input_prmt_channel_glbl_param_11_3unsignedInt 0…655350
input_prmt_channel_glbl_param_22_3unsignedInt 0…655350
input_prmt_channel_glbl_param_33_3unsignedInt 0…655350
input_prmt_channel_glbl_param_10_4unsignedInt 0…655350
input_prmt_channel_glbl_param_21_4unsignedInt 0…655350
input_prmt_channel_glbl_param_32_4unsignedInt 0…655350
input_prmt_channel_glbl_param_20_5unsignedInt 0…655350
input_prmt_channel_glbl_param_31_5unsignedInt 0…655350
input_prmt_channel_glbl_param_30_6unsignedInt 0…655350
input_prmt_channel_glbl_param_5_10unsignedInt 0…655350
input_prmt_channel_glbl_param_6_11unsignedInt 0…655350
Minimum oscillation for sending command value (%)unsignedInt 0…1005
Number of fan levellist3
Send additional heating command value periodically (sec)unsignedInt 0…25510
input_prmt_channel_glbl_param_9_1unsignedInt 0…655350
input_prmt_channel_glbl_param_8_2unsignedInt 0…655350
input_prmt_channel_glbl_param_7_3unsignedInt 0…655350
input_prmt_channel_glbl_param_6_4unsignedInt 0…655350
input_prmt_channel_glbl_param_5_5unsignedInt 0…655350
input_prmt_channel_glbl_param_4_6unsignedInt 0…655350
input_prmt_channel_glbl_param_3_7unsignedInt 0…655350
-> Modification by pressinglistIncrease one step
Logic typelistAND
logic_prmt_channel_glbl_param_5_3unsignedInt 0…655350
logic_prmt_channel_glbl_param_4_4unsignedInt 0…655350
PWM total time for additional cooling system (min)unsignedInt 5…25515
backup_19unsignedInt 0…655350
-> Alarm led toggle time (msec)unsignedInt 0…65535500
Average object typelistPercent Value (%)
avg_prmt_channel_glbl_param_1_1unsignedInt 0…655350
right_upper_button_functionunsignedInt 0…2550
Internal sensor calibrationlist0%
Basic setpointlist23.0 °C
input_prmt_channel_glbl_param_15_0listToggle
input_prmt_channel_glbl_param_26_0unsignedInt 0…655350
input_prmt_channel_glbl_param_14_1unsignedInt 0…655350
input_prmt_channel_glbl_param_25_1unsignedInt 0…655350
input_prmt_channel_glbl_param_13_2unsignedInt 0…655350
input_prmt_channel_glbl_param_24_2unsignedInt 0…655350
input_prmt_channel_glbl_param_35_2unsignedInt 0…655350
input_prmt_channel_glbl_param_12_3unsignedInt 0…655350
input_prmt_channel_glbl_param_23_3unsignedInt 0…655350
input_prmt_channel_glbl_param_34_3unsignedInt 0…655350
input_prmt_channel_glbl_param_11_4unsignedInt 0…655350
input_prmt_channel_glbl_param_22_4unsignedInt 0…655350
input_prmt_channel_glbl_param_33_4unsignedInt 0…655350
input_prmt_channel_glbl_param_10_5unsignedInt 0…655350
input_prmt_channel_glbl_param_21_5unsignedInt 0…655350
input_prmt_channel_glbl_param_32_5unsignedInt 0…655350
input_prmt_channel_glbl_param_20_6unsignedInt 0…655350
input_prmt_channel_glbl_param_31_6unsignedInt 0…655350
input_prmt_channel_glbl_param_30_7unsignedInt 0…655350
input_prmt_channel_glbl_param_4_10unsignedInt 0…655350
input_prmt_channel_glbl_param_5_11unsignedInt 0…655350
Minimum oscillation for sending additional command value (%)unsignedInt 0…1005
input_prmt_channel_glbl_param_9_2unsignedInt 0…655350
input_prmt_channel_glbl_param_8_3unsignedInt 0…655350
input_prmt_channel_glbl_param_7_4unsignedInt 0…655350
input_prmt_channel_glbl_param_6_5unsignedInt 0…655350
input_prmt_channel_glbl_param_5_6unsignedInt 0…655350
input_prmt_channel_glbl_param_4_7unsignedInt 0…655350
-> Step for setpoint controllist0.1K
Number of inputslist5 Inputs
logic_prmt_channel_glbl_param_1_1unsignedInt 0…2550
logic_prmt_channel_glbl_param_5_4unsignedInt 0…655350
Type of additinal cooling systemlistCool ceiling
Additional cooling hysteresis valuelist0.1K
avg_prmt_channel_glbl_param_3_0unsignedInt 0…655350
avg_prmt_channel_glbl_param_2_1unsignedInt 0…655350
avg_prmt_channel_glbl_param_1_2unsignedInt 0…655350
Operating mode after bus recoverylistPrevious mode
--> Outdoor show interval (sec)unsignedInt 0…2553
Use delay time for sending valuelistNO
input_prmt_channel_glbl_param_27_0unsignedInt 0…655350
input_prmt_channel_glbl_param_15_1unsignedInt 0…655350
input_prmt_channel_glbl_param_26_1unsignedInt 0…655350
input_prmt_channel_glbl_param_14_2unsignedInt 0…655350
input_prmt_channel_glbl_param_25_2unsignedInt 0…655350
input_prmt_channel_glbl_param_13_3unsignedInt 0…655350
input_prmt_channel_glbl_param_24_3unsignedInt 0…655350
input_prmt_channel_glbl_param_35_3unsignedInt 0…655350
input_prmt_channel_glbl_param_12_4unsignedInt 0…655350
input_prmt_channel_glbl_param_23_4unsignedInt 0…655350
input_prmt_channel_glbl_param_34_4unsignedInt 0…655350
input_prmt_channel_glbl_param_11_5unsignedInt 0…655350
input_prmt_channel_glbl_param_22_5unsignedInt 0…655350
input_prmt_channel_glbl_param_33_5unsignedInt 0…655350
input_prmt_channel_glbl_param_10_6unsignedInt 0…655350
input_prmt_channel_glbl_param_21_6unsignedInt 0…655350
input_prmt_channel_glbl_param_32_6unsignedInt 0…655350
input_prmt_channel_glbl_param_20_7unsignedInt 0…655350
input_prmt_channel_glbl_param_31_7unsignedInt 0…655350
input_prmt_channel_glbl_param_30_8unsignedInt 0…655350
input_prmt_channel_glbl_param_4_11unsignedInt 0…655350
left_upper_button_fanunsignedInt 0…2550
input_prmt_channel_glbl_param_9_3unsignedInt 0…655350
input_prmt_channel_glbl_param_8_4unsignedInt 0…655350
input_prmt_channel_glbl_param_7_5unsignedInt 0…655350
input_prmt_channel_glbl_param_6_6unsignedInt 0…655350
input_prmt_channel_glbl_param_5_7unsignedInt 0…655350
Off mode in loop ?listEnable
Output value typelist1 Bit
logic_prmt_channel_glbl_param_2_1unsignedInt 0…2550
logic_prmt_channel_glbl_param_1_2unsignedInt 0…2550
Additional cooling minimum control value (%)unsignedInt 0…1000
Heating dependant comfort setpointlist5.0 °C
LCD EnablelistEnable
left_upper_button_opmode_stepunsignedInt 0…2550
right_lower_button_fanunsignedInt 0…2550
avg_prmt_channel_glbl_param_4_0unsignedInt 0…655350
avg_prmt_channel_glbl_param_3_1unsignedInt 0…655350
avg_prmt_channel_glbl_param_2_2unsignedInt 0…655350
avg_prmt_channel_glbl_param_1_3unsignedInt 0…655350
right_upper_button_setpointunsignedInt 0…2550
Heating Cooling changeoverlistVia communication object
Proportional band (K)list4.0K
device_selectionlistRoom Controller (with LCD)
Sending of setpointslistYES
input_prmt_channel_glbl_param_28_0unsignedInt 0…655350
input_prmt_channel_glbl_param_16_1unsignedInt 0…655350
input_prmt_channel_glbl_param_27_1unsignedInt 0…655350
input_prmt_channel_glbl_param_15_2unsignedInt 0…655350
input_prmt_channel_glbl_param_26_2unsignedInt 0…655350
input_prmt_channel_glbl_param_14_3unsignedInt 0…655350
input_prmt_channel_glbl_param_25_3unsignedInt 0…655350
input_prmt_channel_glbl_param_13_4unsignedInt 0…655350
input_prmt_channel_glbl_param_24_4unsignedInt 0…655350
input_prmt_channel_glbl_param_35_4unsignedInt 0…655350
input_prmt_channel_glbl_param_12_5unsignedInt 0…655350
input_prmt_channel_glbl_param_23_5unsignedInt 0…655350
input_prmt_channel_glbl_param_34_5unsignedInt 0…655350
input_prmt_channel_glbl_param_11_6unsignedInt 0…655350
input_prmt_channel_glbl_param_22_6unsignedInt 0…655350
input_prmt_channel_glbl_param_33_6unsignedInt 0…655350
input_prmt_channel_glbl_param_10_7unsignedInt 0…655350
input_prmt_channel_glbl_param_21_7unsignedInt 0…655350
input_prmt_channel_glbl_param_32_7unsignedInt 0…655350
input_prmt_channel_glbl_param_20_8unsignedInt 0…655350
input_prmt_channel_glbl_param_31_8unsignedInt 0…655350
input_prmt_channel_glbl_param_30_9unsignedInt 0…655350
right_lower_button_opmode_stepunsignedInt 0…2550
Additional cooling proportional band (K)list0.5K
input_prmt_channel_glbl_param_9_4unsignedInt 0…655350
input_prmt_channel_glbl_param_8_5unsignedInt 0…655350
input_prmt_channel_glbl_param_7_6unsignedInt 0…655350
input_prmt_channel_glbl_param_6_7unsignedInt 0…655350
Loop step waylistGo Loop
input_prmt_channel_glbl_param_4_9unsignedInt 0…655350
logic_prmt_channel_glbl_param_3_1unsignedInt 0…2550
logic_prmt_channel_glbl_param_2_2unsignedInt 0…2550
logic_prmt_channel_glbl_param_1_3unsignedInt 0…2550
Humidity sensor for room controllerlistInternal
left_upper_button_setpoint_stepunsignedInt 0…2550

First 500 of 954 parameters shown. Download the .knxprod for the full list.

Version history

ApplicationApp noFingerprintFirst seenSizeFile
I-Luxus Thermostat 0.4 latest$000164E92026-11-25936 KBDownload

About this file

This is the official ETS product database for the Goldmedal I-Luxus Room Controller / Push Button (PBI/PTI-000x), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.

More from Goldmedal

All Goldmedal products