KNX Database
GIRA Giersiepen 2089 00 Gira S1

Gira S1 2089 00

GIRA Giersiepen · Order number 2089 00 · Safety › Remote Access

Gira S1

Download .knxprod Gira S1 4.1 · 201 KB

Product

ManufacturerGIRA Giersiepen
Product nameGira S1
Order number2089 00
HardwareKIM Remote Access
MediumTwisted Pair
Bus current (mA)2.5
Rail mountedYes
Width (mm)36
Device kindIPEnabled
RegistrationRegistered · 2017-12-21
Languagesde-DE, en-US, es-ES, fr-FR, it-IT, nl-NL
Catalog entryM-0008_H-ISSDAIKX01-1-O007C_HP-0004-41-EF35-O007C_CI-2089.2000-1
FingerprintEF35
SHA-256bfdbfd267b7c723c5ebebad525993abcba47216d860a455e8654bd502ee69b6c
First seen2026-11-25
Markets39 markets

Application program: Gira S1 4.1

Application number$0004
Version4.1
Mask versionMV-07B0 (System B)
KNX Data SecureNo
Minimum ETS version4.0
Parameters967
Group objects263
Group objects (263)
NoNameFunctionSizeDPTFlags
1Grant remote accessAllows or prohibits the connection of the device to the portal server1 Bit1.3 enableCW
2Grant remote access - statusIndicates whether the device is allowed to connect to the portal server1 Bit1.3 enableCRT
3Grant "Residents" remote accessGrants or denies members of the group "Residents" remote access1 Bit1.3 enableCW
4Grant "Residents" remote access - statusIndicates whether remote access is granted members of the group "Residents"1 Bit1.3 enableCRT
5Grant "Installers" remote accessGrants or denies members of the group "Installers" remote access1 Bit1.3 enableCW
6Grant "Installers" remote access - statusIndicates whether remote access is granted members of the group "Installers"1 Bit1.3 enableCRT
20State portal connectionIndicates whether connection to portal is established. For detailed information see group object 311 Bit1.11 stateCRT
21State any remote connectionIndicates whether any remote connection is currently active1 Bit1.11 stateCRT
22State remote connection "Residents"Indicates whether a remote connection by a member of group "Residents" is currently active1 Bit1.11 stateCRT
23State remote connection "Installers"Indicates whether a remote connection by a member of group "Installers" is currently active1 Bit1.11 stateCRT
30Error indicationIndicates a connection error which is described by group object 32. Further details are available on the Gira S1 device's web page1 Bit1.5 alarmCRT
31Portal connection infoDiagnostic information about the portal connection14 Bytes16.1 Character String (ISO 8859-1)CRT
32Connection error infoAdditional diagnostic text in case of a portal connection error14 Bytes16.1 Character String (ISO 8859-1)CRT
101Notification trigger #1Sends a Notification to the portal. The boolean value can be part of the Notification.1 Bit1.1 switchCW
101Notification trigger #1Sends a Notification to the portal. The percent value can be part of the Notification.1 Byte5.1 percentage (0..100%)CW
101Notification trigger #1Sends a Notification to the portal. The counter value can be part of the Notification.1 Byte5.10 counter pulses (0..255)CW
101Notification trigger #1Sends a Notification to the portal. The float value can be part of the Notification.2 BytesDPT.9CW
101Notification trigger #1Sends a Notification to the portal. The text value can be part of the Notification.14 Bytes16.1 Character String (ISO 8859-1)CW
102Notification trigger #2Sends a Notification to the portal. The boolean value can be part of the Notification.1 Bit1.1 switchCW
102Notification trigger #2Sends a Notification to the portal. The percent value can be part of the Notification.1 Byte5.1 percentage (0..100%)CW
102Notification trigger #2Sends a Notification to the portal. The counter value can be part of the Notification.1 Byte5.10 counter pulses (0..255)CW
102Notification trigger #2Sends a Notification to the portal. The float value can be part of the Notification.2 BytesDPT.9CW
102Notification trigger #2Sends a Notification to the portal. The text value can be part of the Notification.14 Bytes16.1 Character String (ISO 8859-1)CW
103Notification trigger #3Sends a Notification to the portal. The boolean value can be part of the Notification.1 Bit1.1 switchCW
103Notification trigger #3Sends a Notification to the portal. The percent value can be part of the Notification.1 Byte5.1 percentage (0..100%)CW
103Notification trigger #3Sends a Notification to the portal. The counter value can be part of the Notification.1 Byte5.10 counter pulses (0..255)CW
103Notification trigger #3Sends a Notification to the portal. The float value can be part of the Notification.2 BytesDPT.9CW
103Notification trigger #3Sends a Notification to the portal. The text value can be part of the Notification.14 Bytes16.1 Character String (ISO 8859-1)CW
104Notification trigger #4Sends a Notification to the portal. The boolean value can be part of the Notification.1 Bit1.1 switchCW
104Notification trigger #4Sends a Notification to the portal. The percent value can be part of the Notification.1 Byte5.1 percentage (0..100%)CW
104Notification trigger #4Sends a Notification to the portal. The counter value can be part of the Notification.1 Byte5.10 counter pulses (0..255)CW
104Notification trigger #4Sends a Notification to the portal. The float value can be part of the Notification.2 BytesDPT.9CW
104Notification trigger #4Sends a Notification to the portal. The text value can be part of the Notification.14 Bytes16.1 Character String (ISO 8859-1)CW
105Notification trigger #5Sends a Notification to the portal. The boolean value can be part of the Notification.1 Bit1.1 switchCW
105Notification trigger #5Sends a Notification to the portal. The percent value can be part of the Notification.1 Byte5.1 percentage (0..100%)CW
105Notification trigger #5Sends a Notification to the portal. The counter value can be part of the Notification.1 Byte5.10 counter pulses (0..255)CW
105Notification trigger #5Sends a Notification to the portal. The float value can be part of the Notification.2 BytesDPT.9CW
105Notification trigger #5Sends a Notification to the portal. The text value can be part of the Notification.14 Bytes16.1 Character String (ISO 8859-1)CW
106Notification trigger #6Sends a Notification to the portal. The boolean value can be part of the Notification.1 Bit1.1 switchCW
106Notification trigger #6Sends a Notification to the portal. The percent value can be part of the Notification.1 Byte5.1 percentage (0..100%)CW
106Notification trigger #6Sends a Notification to the portal. The counter value can be part of the Notification.1 Byte5.10 counter pulses (0..255)CW
106Notification trigger #6Sends a Notification to the portal. The float value can be part of the Notification.2 BytesDPT.9CW
106Notification trigger #6Sends a Notification to the portal. The text value can be part of the Notification.14 Bytes16.1 Character String (ISO 8859-1)CW
107Notification trigger #7Sends a Notification to the portal. The boolean value can be part of the Notification.1 Bit1.1 switchCW
107Notification trigger #7Sends a Notification to the portal. The percent value can be part of the Notification.1 Byte5.1 percentage (0..100%)CW
107Notification trigger #7Sends a Notification to the portal. The counter value can be part of the Notification.1 Byte5.10 counter pulses (0..255)CW
107Notification trigger #7Sends a Notification to the portal. The float value can be part of the Notification.2 BytesDPT.9CW
107Notification trigger #7Sends a Notification to the portal. The text value can be part of the Notification.14 Bytes16.1 Character String (ISO 8859-1)CW
108Notification trigger #8Sends a Notification to the portal. The boolean value can be part of the Notification.1 Bit1.1 switchCW
108Notification trigger #8Sends a Notification to the portal. The percent value can be part of the Notification.1 Byte5.1 percentage (0..100%)CW
108Notification trigger #8Sends a Notification to the portal. The counter value can be part of the Notification.1 Byte5.10 counter pulses (0..255)CW
108Notification trigger #8Sends a Notification to the portal. The float value can be part of the Notification.2 BytesDPT.9CW
108Notification trigger #8Sends a Notification to the portal. The text value can be part of the Notification.14 Bytes16.1 Character String (ISO 8859-1)CW
109Notification trigger #9Sends a Notification to the portal. The boolean value can be part of the Notification.1 Bit1.1 switchCW
109Notification trigger #9Sends a Notification to the portal. The percent value can be part of the Notification.1 Byte5.1 percentage (0..100%)CW
109Notification trigger #9Sends a Notification to the portal. The counter value can be part of the Notification.1 Byte5.10 counter pulses (0..255)CW
109Notification trigger #9Sends a Notification to the portal. The float value can be part of the Notification.2 BytesDPT.9CW
109Notification trigger #9Sends a Notification to the portal. The text value can be part of the Notification.14 Bytes16.1 Character String (ISO 8859-1)CW
110Notification trigger #10Sends a Notification to the portal. The boolean value can be part of the Notification.1 Bit1.1 switchCW
110Notification trigger #10Sends a Notification to the portal. The percent value can be part of the Notification.1 Byte5.1 percentage (0..100%)CW
110Notification trigger #10Sends a Notification to the portal. The counter value can be part of the Notification.1 Byte5.10 counter pulses (0..255)CW
110Notification trigger #10Sends a Notification to the portal. The float value can be part of the Notification.2 BytesDPT.9CW
110Notification trigger #10Sends a Notification to the portal. The text value can be part of the Notification.14 Bytes16.1 Character String (ISO 8859-1)CW
111Notification trigger #11Sends a Notification to the portal. The boolean value can be part of the Notification.1 Bit1.1 switchCW
111Notification trigger #11Sends a Notification to the portal. The percent value can be part of the Notification.1 Byte5.1 percentage (0..100%)CW
111Notification trigger #11Sends a Notification to the portal. The counter value can be part of the Notification.1 Byte5.10 counter pulses (0..255)CW
111Notification trigger #11Sends a Notification to the portal. The float value can be part of the Notification.2 BytesDPT.9CW
111Notification trigger #11Sends a Notification to the portal. The text value can be part of the Notification.14 Bytes16.1 Character String (ISO 8859-1)CW
112Notification trigger #12Sends a Notification to the portal. The boolean value can be part of the Notification.1 Bit1.1 switchCW
112Notification trigger #12Sends a Notification to the portal. The percent value can be part of the Notification.1 Byte5.1 percentage (0..100%)CW
112Notification trigger #12Sends a Notification to the portal. The counter value can be part of the Notification.1 Byte5.10 counter pulses (0..255)CW
112Notification trigger #12Sends a Notification to the portal. The float value can be part of the Notification.2 BytesDPT.9CW
112Notification trigger #12Sends a Notification to the portal. The text value can be part of the Notification.14 Bytes16.1 Character String (ISO 8859-1)CW
113Notification trigger #13Sends a Notification to the portal. The boolean value can be part of the Notification.1 Bit1.1 switchCW
113Notification trigger #13Sends a Notification to the portal. The percent value can be part of the Notification.1 Byte5.1 percentage (0..100%)CW
113Notification trigger #13Sends a Notification to the portal. The counter value can be part of the Notification.1 Byte5.10 counter pulses (0..255)CW
113Notification trigger #13Sends a Notification to the portal. The float value can be part of the Notification.2 BytesDPT.9CW
113Notification trigger #13Sends a Notification to the portal. The text value can be part of the Notification.14 Bytes16.1 Character String (ISO 8859-1)CW
114Notification trigger #14Sends a Notification to the portal. The boolean value can be part of the Notification.1 Bit1.1 switchCW
114Notification trigger #14Sends a Notification to the portal. The percent value can be part of the Notification.1 Byte5.1 percentage (0..100%)CW
114Notification trigger #14Sends a Notification to the portal. The counter value can be part of the Notification.1 Byte5.10 counter pulses (0..255)CW
114Notification trigger #14Sends a Notification to the portal. The float value can be part of the Notification.2 BytesDPT.9CW
114Notification trigger #14Sends a Notification to the portal. The text value can be part of the Notification.14 Bytes16.1 Character String (ISO 8859-1)CW
115Notification trigger #15Sends a Notification to the portal. The boolean value can be part of the Notification.1 Bit1.1 switchCW
115Notification trigger #15Sends a Notification to the portal. The percent value can be part of the Notification.1 Byte5.1 percentage (0..100%)CW
115Notification trigger #15Sends a Notification to the portal. The counter value can be part of the Notification.1 Byte5.10 counter pulses (0..255)CW
115Notification trigger #15Sends a Notification to the portal. The float value can be part of the Notification.2 BytesDPT.9CW
115Notification trigger #15Sends a Notification to the portal. The text value can be part of the Notification.14 Bytes16.1 Character String (ISO 8859-1)CW
116Notification trigger #16Sends a Notification to the portal. The boolean value can be part of the Notification.1 Bit1.1 switchCW
116Notification trigger #16Sends a Notification to the portal. The percent value can be part of the Notification.1 Byte5.1 percentage (0..100%)CW
116Notification trigger #16Sends a Notification to the portal. The counter value can be part of the Notification.1 Byte5.10 counter pulses (0..255)CW
116Notification trigger #16Sends a Notification to the portal. The float value can be part of the Notification.2 BytesDPT.9CW
116Notification trigger #16Sends a Notification to the portal. The text value can be part of the Notification.14 Bytes16.1 Character String (ISO 8859-1)CW
117Notification trigger #17Sends a Notification to the portal. The boolean value can be part of the Notification.1 Bit1.1 switchCW
117Notification trigger #17Sends a Notification to the portal. The percent value can be part of the Notification.1 Byte5.1 percentage (0..100%)CW
117Notification trigger #17Sends a Notification to the portal. The counter value can be part of the Notification.1 Byte5.10 counter pulses (0..255)CW
117Notification trigger #17Sends a Notification to the portal. The float value can be part of the Notification.2 BytesDPT.9CW
117Notification trigger #17Sends a Notification to the portal. The text value can be part of the Notification.14 Bytes16.1 Character String (ISO 8859-1)CW
118Notification trigger #18Sends a Notification to the portal. The boolean value can be part of the Notification.1 Bit1.1 switchCW
118Notification trigger #18Sends a Notification to the portal. The percent value can be part of the Notification.1 Byte5.1 percentage (0..100%)CW
118Notification trigger #18Sends a Notification to the portal. The counter value can be part of the Notification.1 Byte5.10 counter pulses (0..255)CW
118Notification trigger #18Sends a Notification to the portal. The float value can be part of the Notification.2 BytesDPT.9CW
118Notification trigger #18Sends a Notification to the portal. The text value can be part of the Notification.14 Bytes16.1 Character String (ISO 8859-1)CW
119Notification trigger #19Sends a Notification to the portal. The boolean value can be part of the Notification.1 Bit1.1 switchCW
119Notification trigger #19Sends a Notification to the portal. The percent value can be part of the Notification.1 Byte5.1 percentage (0..100%)CW
119Notification trigger #19Sends a Notification to the portal. The counter value can be part of the Notification.1 Byte5.10 counter pulses (0..255)CW
119Notification trigger #19Sends a Notification to the portal. The float value can be part of the Notification.2 BytesDPT.9CW
119Notification trigger #19Sends a Notification to the portal. The text value can be part of the Notification.14 Bytes16.1 Character String (ISO 8859-1)CW
120Notification trigger #20Sends a Notification to the portal. The boolean value can be part of the Notification.1 Bit1.1 switchCW
120Notification trigger #20Sends a Notification to the portal. The percent value can be part of the Notification.1 Byte5.1 percentage (0..100%)CW
120Notification trigger #20Sends a Notification to the portal. The counter value can be part of the Notification.1 Byte5.10 counter pulses (0..255)CW
120Notification trigger #20Sends a Notification to the portal. The float value can be part of the Notification.2 BytesDPT.9CW
120Notification trigger #20Sends a Notification to the portal. The text value can be part of the Notification.14 Bytes16.1 Character String (ISO 8859-1)CW
121Notification trigger #21Sends a Notification to the portal. The boolean value can be part of the Notification.1 Bit1.1 switchCW
121Notification trigger #21Sends a Notification to the portal. The percent value can be part of the Notification.1 Byte5.1 percentage (0..100%)CW
121Notification trigger #21Sends a Notification to the portal. The counter value can be part of the Notification.1 Byte5.10 counter pulses (0..255)CW
121Notification trigger #21Sends a Notification to the portal. The float value can be part of the Notification.2 BytesDPT.9CW
121Notification trigger #21Sends a Notification to the portal. The text value can be part of the Notification.14 Bytes16.1 Character String (ISO 8859-1)CW
122Notification trigger #22Sends a Notification to the portal. The boolean value can be part of the Notification.1 Bit1.1 switchCW
122Notification trigger #22Sends a Notification to the portal. The percent value can be part of the Notification.1 Byte5.1 percentage (0..100%)CW
122Notification trigger #22Sends a Notification to the portal. The counter value can be part of the Notification.1 Byte5.10 counter pulses (0..255)CW
122Notification trigger #22Sends a Notification to the portal. The float value can be part of the Notification.2 BytesDPT.9CW
122Notification trigger #22Sends a Notification to the portal. The text value can be part of the Notification.14 Bytes16.1 Character String (ISO 8859-1)CW
123Notification trigger #23Sends a Notification to the portal. The boolean value can be part of the Notification.1 Bit1.1 switchCW
123Notification trigger #23Sends a Notification to the portal. The percent value can be part of the Notification.1 Byte5.1 percentage (0..100%)CW
123Notification trigger #23Sends a Notification to the portal. The counter value can be part of the Notification.1 Byte5.10 counter pulses (0..255)CW
123Notification trigger #23Sends a Notification to the portal. The float value can be part of the Notification.2 BytesDPT.9CW
123Notification trigger #23Sends a Notification to the portal. The text value can be part of the Notification.14 Bytes16.1 Character String (ISO 8859-1)CW
124Notification trigger #24Sends a Notification to the portal. The boolean value can be part of the Notification.1 Bit1.1 switchCW
124Notification trigger #24Sends a Notification to the portal. The percent value can be part of the Notification.1 Byte5.1 percentage (0..100%)CW
124Notification trigger #24Sends a Notification to the portal. The counter value can be part of the Notification.1 Byte5.10 counter pulses (0..255)CW
124Notification trigger #24Sends a Notification to the portal. The float value can be part of the Notification.2 BytesDPT.9CW
124Notification trigger #24Sends a Notification to the portal. The text value can be part of the Notification.14 Bytes16.1 Character String (ISO 8859-1)CW
125Notification trigger #25Sends a Notification to the portal. The boolean value can be part of the Notification.1 Bit1.1 switchCW
125Notification trigger #25Sends a Notification to the portal. The percent value can be part of the Notification.1 Byte5.1 percentage (0..100%)CW
125Notification trigger #25Sends a Notification to the portal. The counter value can be part of the Notification.1 Byte5.10 counter pulses (0..255)CW
125Notification trigger #25Sends a Notification to the portal. The float value can be part of the Notification.2 BytesDPT.9CW
125Notification trigger #25Sends a Notification to the portal. The text value can be part of the Notification.14 Bytes16.1 Character String (ISO 8859-1)CW
126Notification trigger #26Sends a Notification to the portal. The boolean value can be part of the Notification.1 Bit1.1 switchCW
126Notification trigger #26Sends a Notification to the portal. The percent value can be part of the Notification.1 Byte5.1 percentage (0..100%)CW
126Notification trigger #26Sends a Notification to the portal. The counter value can be part of the Notification.1 Byte5.10 counter pulses (0..255)CW
126Notification trigger #26Sends a Notification to the portal. The float value can be part of the Notification.2 BytesDPT.9CW
126Notification trigger #26Sends a Notification to the portal. The text value can be part of the Notification.14 Bytes16.1 Character String (ISO 8859-1)CW
127Notification trigger #27Sends a Notification to the portal. The boolean value can be part of the Notification.1 Bit1.1 switchCW
127Notification trigger #27Sends a Notification to the portal. The percent value can be part of the Notification.1 Byte5.1 percentage (0..100%)CW
127Notification trigger #27Sends a Notification to the portal. The counter value can be part of the Notification.1 Byte5.10 counter pulses (0..255)CW
127Notification trigger #27Sends a Notification to the portal. The float value can be part of the Notification.2 BytesDPT.9CW
127Notification trigger #27Sends a Notification to the portal. The text value can be part of the Notification.14 Bytes16.1 Character String (ISO 8859-1)CW
128Notification trigger #28Sends a Notification to the portal. The boolean value can be part of the Notification.1 Bit1.1 switchCW
128Notification trigger #28Sends a Notification to the portal. The percent value can be part of the Notification.1 Byte5.1 percentage (0..100%)CW
128Notification trigger #28Sends a Notification to the portal. The counter value can be part of the Notification.1 Byte5.10 counter pulses (0..255)CW
128Notification trigger #28Sends a Notification to the portal. The float value can be part of the Notification.2 BytesDPT.9CW
128Notification trigger #28Sends a Notification to the portal. The text value can be part of the Notification.14 Bytes16.1 Character String (ISO 8859-1)CW
129Notification trigger #29Sends a Notification to the portal. The boolean value can be part of the Notification.1 Bit1.1 switchCW
129Notification trigger #29Sends a Notification to the portal. The percent value can be part of the Notification.1 Byte5.1 percentage (0..100%)CW
129Notification trigger #29Sends a Notification to the portal. The counter value can be part of the Notification.1 Byte5.10 counter pulses (0..255)CW
129Notification trigger #29Sends a Notification to the portal. The float value can be part of the Notification.2 BytesDPT.9CW
129Notification trigger #29Sends a Notification to the portal. The text value can be part of the Notification.14 Bytes16.1 Character String (ISO 8859-1)CW
130Notification trigger #30Sends a Notification to the portal. The boolean value can be part of the Notification.1 Bit1.1 switchCW
130Notification trigger #30Sends a Notification to the portal. The percent value can be part of the Notification.1 Byte5.1 percentage (0..100%)CW
130Notification trigger #30Sends a Notification to the portal. The counter value can be part of the Notification.1 Byte5.10 counter pulses (0..255)CW
130Notification trigger #30Sends a Notification to the portal. The float value can be part of the Notification.2 BytesDPT.9CW
130Notification trigger #30Sends a Notification to the portal. The text value can be part of the Notification.14 Bytes16.1 Character String (ISO 8859-1)CW
131Notification trigger #31Sends a Notification to the portal. The boolean value can be part of the Notification.1 Bit1.1 switchCW
131Notification trigger #31Sends a Notification to the portal. The percent value can be part of the Notification.1 Byte5.1 percentage (0..100%)CW
131Notification trigger #31Sends a Notification to the portal. The counter value can be part of the Notification.1 Byte5.10 counter pulses (0..255)CW
131Notification trigger #31Sends a Notification to the portal. The float value can be part of the Notification.2 BytesDPT.9CW
131Notification trigger #31Sends a Notification to the portal. The text value can be part of the Notification.14 Bytes16.1 Character String (ISO 8859-1)CW
132Notification trigger #32Sends a Notification to the portal. The boolean value can be part of the Notification.1 Bit1.1 switchCW
132Notification trigger #32Sends a Notification to the portal. The percent value can be part of the Notification.1 Byte5.1 percentage (0..100%)CW
132Notification trigger #32Sends a Notification to the portal. The counter value can be part of the Notification.1 Byte5.10 counter pulses (0..255)CW
132Notification trigger #32Sends a Notification to the portal. The float value can be part of the Notification.2 BytesDPT.9CW
132Notification trigger #32Sends a Notification to the portal. The text value can be part of the Notification.14 Bytes16.1 Character String (ISO 8859-1)CW
133Notification trigger #33Sends a Notification to the portal. The boolean value can be part of the Notification.1 Bit1.1 switchCW
133Notification trigger #33Sends a Notification to the portal. The percent value can be part of the Notification.1 Byte5.1 percentage (0..100%)CW
133Notification trigger #33Sends a Notification to the portal. The counter value can be part of the Notification.1 Byte5.10 counter pulses (0..255)CW
133Notification trigger #33Sends a Notification to the portal. The float value can be part of the Notification.2 BytesDPT.9CW
133Notification trigger #33Sends a Notification to the portal. The text value can be part of the Notification.14 Bytes16.1 Character String (ISO 8859-1)CW
134Notification trigger #34Sends a Notification to the portal. The boolean value can be part of the Notification.1 Bit1.1 switchCW
134Notification trigger #34Sends a Notification to the portal. The percent value can be part of the Notification.1 Byte5.1 percentage (0..100%)CW
134Notification trigger #34Sends a Notification to the portal. The counter value can be part of the Notification.1 Byte5.10 counter pulses (0..255)CW
134Notification trigger #34Sends a Notification to the portal. The float value can be part of the Notification.2 BytesDPT.9CW
134Notification trigger #34Sends a Notification to the portal. The text value can be part of the Notification.14 Bytes16.1 Character String (ISO 8859-1)CW
135Notification trigger #35Sends a Notification to the portal. The boolean value can be part of the Notification.1 Bit1.1 switchCW
135Notification trigger #35Sends a Notification to the portal. The percent value can be part of the Notification.1 Byte5.1 percentage (0..100%)CW
135Notification trigger #35Sends a Notification to the portal. The counter value can be part of the Notification.1 Byte5.10 counter pulses (0..255)CW
135Notification trigger #35Sends a Notification to the portal. The float value can be part of the Notification.2 BytesDPT.9CW
135Notification trigger #35Sends a Notification to the portal. The text value can be part of the Notification.14 Bytes16.1 Character String (ISO 8859-1)CW
136Notification trigger #36Sends a Notification to the portal. The boolean value can be part of the Notification.1 Bit1.1 switchCW
136Notification trigger #36Sends a Notification to the portal. The percent value can be part of the Notification.1 Byte5.1 percentage (0..100%)CW
136Notification trigger #36Sends a Notification to the portal. The counter value can be part of the Notification.1 Byte5.10 counter pulses (0..255)CW
136Notification trigger #36Sends a Notification to the portal. The float value can be part of the Notification.2 BytesDPT.9CW
136Notification trigger #36Sends a Notification to the portal. The text value can be part of the Notification.14 Bytes16.1 Character String (ISO 8859-1)CW
137Notification trigger #37Sends a Notification to the portal. The boolean value can be part of the Notification.1 Bit1.1 switchCW
137Notification trigger #37Sends a Notification to the portal. The percent value can be part of the Notification.1 Byte5.1 percentage (0..100%)CW
137Notification trigger #37Sends a Notification to the portal. The counter value can be part of the Notification.1 Byte5.10 counter pulses (0..255)CW
137Notification trigger #37Sends a Notification to the portal. The float value can be part of the Notification.2 BytesDPT.9CW
137Notification trigger #37Sends a Notification to the portal. The text value can be part of the Notification.14 Bytes16.1 Character String (ISO 8859-1)CW
138Notification trigger #38Sends a Notification to the portal. The boolean value can be part of the Notification.1 Bit1.1 switchCW
138Notification trigger #38Sends a Notification to the portal. The percent value can be part of the Notification.1 Byte5.1 percentage (0..100%)CW
138Notification trigger #38Sends a Notification to the portal. The counter value can be part of the Notification.1 Byte5.10 counter pulses (0..255)CW
138Notification trigger #38Sends a Notification to the portal. The float value can be part of the Notification.2 BytesDPT.9CW
138Notification trigger #38Sends a Notification to the portal. The text value can be part of the Notification.14 Bytes16.1 Character String (ISO 8859-1)CW
139Notification trigger #39Sends a Notification to the portal. The boolean value can be part of the Notification.1 Bit1.1 switchCW
139Notification trigger #39Sends a Notification to the portal. The percent value can be part of the Notification.1 Byte5.1 percentage (0..100%)CW
139Notification trigger #39Sends a Notification to the portal. The counter value can be part of the Notification.1 Byte5.10 counter pulses (0..255)CW
139Notification trigger #39Sends a Notification to the portal. The float value can be part of the Notification.2 BytesDPT.9CW
139Notification trigger #39Sends a Notification to the portal. The text value can be part of the Notification.14 Bytes16.1 Character String (ISO 8859-1)CW
140Notification trigger #40Sends a Notification to the portal. The boolean value can be part of the Notification.1 Bit1.1 switchCW
140Notification trigger #40Sends a Notification to the portal. The percent value can be part of the Notification.1 Byte5.1 percentage (0..100%)CW
140Notification trigger #40Sends a Notification to the portal. The counter value can be part of the Notification.1 Byte5.10 counter pulses (0..255)CW
140Notification trigger #40Sends a Notification to the portal. The float value can be part of the Notification.2 BytesDPT.9CW
140Notification trigger #40Sends a Notification to the portal. The text value can be part of the Notification.14 Bytes16.1 Character String (ISO 8859-1)CW
141Notification trigger #41Sends a Notification to the portal. The boolean value can be part of the Notification.1 Bit1.1 switchCW
141Notification trigger #41Sends a Notification to the portal. The percent value can be part of the Notification.1 Byte5.1 percentage (0..100%)CW
141Notification trigger #41Sends a Notification to the portal. The counter value can be part of the Notification.1 Byte5.10 counter pulses (0..255)CW
141Notification trigger #41Sends a Notification to the portal. The float value can be part of the Notification.2 BytesDPT.9CW
141Notification trigger #41Sends a Notification to the portal. The text value can be part of the Notification.14 Bytes16.1 Character String (ISO 8859-1)CW
142Notification trigger #42Sends a Notification to the portal. The boolean value can be part of the Notification.1 Bit1.1 switchCW
142Notification trigger #42Sends a Notification to the portal. The percent value can be part of the Notification.1 Byte5.1 percentage (0..100%)CW
142Notification trigger #42Sends a Notification to the portal. The counter value can be part of the Notification.1 Byte5.10 counter pulses (0..255)CW
142Notification trigger #42Sends a Notification to the portal. The float value can be part of the Notification.2 BytesDPT.9CW
142Notification trigger #42Sends a Notification to the portal. The text value can be part of the Notification.14 Bytes16.1 Character String (ISO 8859-1)CW
143Notification trigger #43Sends a Notification to the portal. The boolean value can be part of the Notification.1 Bit1.1 switchCW
143Notification trigger #43Sends a Notification to the portal. The percent value can be part of the Notification.1 Byte5.1 percentage (0..100%)CW
143Notification trigger #43Sends a Notification to the portal. The counter value can be part of the Notification.1 Byte5.10 counter pulses (0..255)CW
143Notification trigger #43Sends a Notification to the portal. The float value can be part of the Notification.2 BytesDPT.9CW
143Notification trigger #43Sends a Notification to the portal. The text value can be part of the Notification.14 Bytes16.1 Character String (ISO 8859-1)CW
144Notification trigger #44Sends a Notification to the portal. The boolean value can be part of the Notification.1 Bit1.1 switchCW
144Notification trigger #44Sends a Notification to the portal. The percent value can be part of the Notification.1 Byte5.1 percentage (0..100%)CW
144Notification trigger #44Sends a Notification to the portal. The counter value can be part of the Notification.1 Byte5.10 counter pulses (0..255)CW
144Notification trigger #44Sends a Notification to the portal. The float value can be part of the Notification.2 BytesDPT.9CW
144Notification trigger #44Sends a Notification to the portal. The text value can be part of the Notification.14 Bytes16.1 Character String (ISO 8859-1)CW
145Notification trigger #45Sends a Notification to the portal. The boolean value can be part of the Notification.1 Bit1.1 switchCW
145Notification trigger #45Sends a Notification to the portal. The percent value can be part of the Notification.1 Byte5.1 percentage (0..100%)CW
145Notification trigger #45Sends a Notification to the portal. The counter value can be part of the Notification.1 Byte5.10 counter pulses (0..255)CW
145Notification trigger #45Sends a Notification to the portal. The float value can be part of the Notification.2 BytesDPT.9CW
145Notification trigger #45Sends a Notification to the portal. The text value can be part of the Notification.14 Bytes16.1 Character String (ISO 8859-1)CW
146Notification trigger #46Sends a Notification to the portal. The boolean value can be part of the Notification.1 Bit1.1 switchCW
146Notification trigger #46Sends a Notification to the portal. The percent value can be part of the Notification.1 Byte5.1 percentage (0..100%)CW
146Notification trigger #46Sends a Notification to the portal. The counter value can be part of the Notification.1 Byte5.10 counter pulses (0..255)CW
146Notification trigger #46Sends a Notification to the portal. The float value can be part of the Notification.2 BytesDPT.9CW
146Notification trigger #46Sends a Notification to the portal. The text value can be part of the Notification.14 Bytes16.1 Character String (ISO 8859-1)CW
147Notification trigger #47Sends a Notification to the portal. The boolean value can be part of the Notification.1 Bit1.1 switchCW
147Notification trigger #47Sends a Notification to the portal. The percent value can be part of the Notification.1 Byte5.1 percentage (0..100%)CW
147Notification trigger #47Sends a Notification to the portal. The counter value can be part of the Notification.1 Byte5.10 counter pulses (0..255)CW
147Notification trigger #47Sends a Notification to the portal. The float value can be part of the Notification.2 BytesDPT.9CW
147Notification trigger #47Sends a Notification to the portal. The text value can be part of the Notification.14 Bytes16.1 Character String (ISO 8859-1)CW
148Notification trigger #48Sends a Notification to the portal. The boolean value can be part of the Notification.1 Bit1.1 switchCW
148Notification trigger #48Sends a Notification to the portal. The percent value can be part of the Notification.1 Byte5.1 percentage (0..100%)CW
148Notification trigger #48Sends a Notification to the portal. The counter value can be part of the Notification.1 Byte5.10 counter pulses (0..255)CW
148Notification trigger #48Sends a Notification to the portal. The float value can be part of the Notification.2 BytesDPT.9CW
148Notification trigger #48Sends a Notification to the portal. The text value can be part of the Notification.14 Bytes16.1 Character String (ISO 8859-1)CW
149Notification trigger #49Sends a Notification to the portal. The boolean value can be part of the Notification.1 Bit1.1 switchCW
149Notification trigger #49Sends a Notification to the portal. The percent value can be part of the Notification.1 Byte5.1 percentage (0..100%)CW
149Notification trigger #49Sends a Notification to the portal. The counter value can be part of the Notification.1 Byte5.10 counter pulses (0..255)CW
149Notification trigger #49Sends a Notification to the portal. The float value can be part of the Notification.2 BytesDPT.9CW
149Notification trigger #49Sends a Notification to the portal. The text value can be part of the Notification.14 Bytes16.1 Character String (ISO 8859-1)CW
150Notification trigger #50Sends a Notification to the portal. The boolean value can be part of the Notification.1 Bit1.1 switchCW
150Notification trigger #50Sends a Notification to the portal. The percent value can be part of the Notification.1 Byte5.1 percentage (0..100%)CW
150Notification trigger #50Sends a Notification to the portal. The counter value can be part of the Notification.1 Byte5.10 counter pulses (0..255)CW
150Notification trigger #50Sends a Notification to the portal. The float value can be part of the Notification.2 BytesDPT.9CW
150Notification trigger #50Sends a Notification to the portal. The text value can be part of the Notification.14 Bytes16.1 Character String (ISO 8859-1)CW
Parameters (328)
ParameterTypeDefault
HardwareTypelist
DptCo1unsignedInt 0…429496729565539
DptCo2unsignedInt 0…429496729565539
DptCo3unsignedInt 0…429496729565539
DptCo4unsignedInt 0…429496729565539
DptCo5unsignedInt 0…429496729565539
DptCo6unsignedInt 0…429496729565539
DptCo7unsignedInt 0…429496729565539
DptCo8unsignedInt 0…429496729565539
DptCo9unsignedInt 0…42949672951
DptCo10unsignedInt 0…42949672951
DptCo11unsignedInt 0…42949672951
DptCo12unsignedInt 0…42949672951
DptCo13unsignedInt 0…42949672951
DptCo14unsignedInt 0…42949672951
DptCo15unsignedInt 0…42949672951
DptCo16unsignedInt 0…42949672951
DptCo17unsignedInt 0…42949672951
DptCo18unsignedInt 0…42949672951
DptCo19unsignedInt 0…42949672951
DptCo20unsignedInt 0…429496729565547
DptCo21unsignedInt 0…429496729565547
DptCo22unsignedInt 0…429496729565547
DptCo23unsignedInt 0…429496729565547
DptCo24unsignedInt 0…429496729565547
DptCo25unsignedInt 0…42949672951
DptCo26unsignedInt 0…42949672951
DptCo27unsignedInt 0…42949672951
DptCo28unsignedInt 0…42949672951
DptCo29unsignedInt 0…42949672951
DptCo30unsignedInt 0…429496729565541
DptCo31unsignedInt 0…42949672951048577
DptCo32unsignedInt 0…42949672951048577
DptCo33unsignedInt 0…42949672951
DptCo34unsignedInt 0…42949672951
DptCo35unsignedInt 0…42949672951
DptCo36unsignedInt 0…42949672951
DptCo37unsignedInt 0…42949672951
DptCo38unsignedInt 0…42949672951
DptCo39unsignedInt 0…42949672951
DptCo40unsignedInt 0…42949672951
DptCo41unsignedInt 0…42949672951
DptCo42unsignedInt 0…42949672951
DptCo43unsignedInt 0…42949672951
DptCo44unsignedInt 0…42949672951
DptCo45unsignedInt 0…42949672951
DptCo46unsignedInt 0…42949672951
DptCo47unsignedInt 0…42949672951
DptCo48unsignedInt 0…42949672951
DptCo49unsignedInt 0…42949672951
DptCo50unsignedInt 0…42949672951
DptCo51unsignedInt 0…42949672951
DptCo52unsignedInt 0…42949672951
DptCo53unsignedInt 0…42949672951
DptCo54unsignedInt 0…42949672951
DptCo55unsignedInt 0…42949672951
DptCo56unsignedInt 0…42949672951
DptCo57unsignedInt 0…42949672951
DptCo58unsignedInt 0…42949672951
DptCo59unsignedInt 0…42949672951
DptCo60unsignedInt 0…42949672951
DptCo61unsignedInt 0…42949672951
DptCo62unsignedInt 0…42949672951
DptCo63unsignedInt 0…42949672951
DptCo64unsignedInt 0…42949672951
DptCo65unsignedInt 0…42949672951
DptCo66unsignedInt 0…42949672951
DptCo67unsignedInt 0…42949672951
DptCo68unsignedInt 0…42949672951
DptCo69unsignedInt 0…42949672951
DptCo70unsignedInt 0…42949672951
DptCo71unsignedInt 0…42949672951
DptCo72unsignedInt 0…42949672951
DptCo73unsignedInt 0…42949672951
DptCo74unsignedInt 0…42949672951
DptCo75unsignedInt 0…42949672951
DptCo76unsignedInt 0…42949672951
DptCo77unsignedInt 0…42949672951
DptCo78unsignedInt 0…42949672951
DptCo79unsignedInt 0…42949672951
DptCo80unsignedInt 0…42949672951
DptCo81unsignedInt 0…42949672951
DptCo82unsignedInt 0…42949672951
DptCo83unsignedInt 0…42949672951
DptCo84unsignedInt 0…42949672951
DptCo85unsignedInt 0…42949672951
DptCo86unsignedInt 0…42949672951
DptCo87unsignedInt 0…42949672951
DptCo88unsignedInt 0…42949672951
DptCo89unsignedInt 0…42949672951
DptCo90unsignedInt 0…42949672951
DptCo91unsignedInt 0…42949672951
DptCo92unsignedInt 0…42949672951
DptCo93unsignedInt 0…42949672951
DptCo94unsignedInt 0…42949672951
DptCo95unsignedInt 0…42949672951
DptCo96unsignedInt 0…42949672951
DptCo97unsignedInt 0…42949672951
DptCo98unsignedInt 0…42949672951
DptCo99unsignedInt 0…42949672951
DptCo100unsignedInt 0…42949672951
DptCo101unsignedInt 0…42949672951048577
DptCo102unsignedInt 0…42949672951048577
DptCo103unsignedInt 0…42949672951048577
DptCo104unsignedInt 0…42949672951048577
DptCo105unsignedInt 0…42949672951048577
DptCo106unsignedInt 0…42949672951048577
DptCo107unsignedInt 0…42949672951048577
DptCo108unsignedInt 0…42949672951048577
DptCo109unsignedInt 0…42949672951048577
DptCo110unsignedInt 0…42949672951048577
DptCo111unsignedInt 0…42949672951048577
DptCo112unsignedInt 0…42949672951048577
DptCo113unsignedInt 0…42949672951048577
DptCo114unsignedInt 0…42949672951048577
DptCo115unsignedInt 0…42949672951048577
DptCo116unsignedInt 0…42949672951048577
DptCo117unsignedInt 0…42949672951048577
DptCo118unsignedInt 0…42949672951048577
DptCo119unsignedInt 0…42949672951048577
DptCo120unsignedInt 0…42949672951048577
DptCo121unsignedInt 0…42949672951048577
DptCo122unsignedInt 0…42949672951048577
DptCo123unsignedInt 0…42949672951048577
DptCo124unsignedInt 0…42949672951048577
DptCo125unsignedInt 0…42949672951048577
DptCo126unsignedInt 0…42949672951048577
DptCo127unsignedInt 0…42949672951048577
DptCo128unsignedInt 0…42949672951048577
DptCo129unsignedInt 0…42949672951048577
DptCo130unsignedInt 0…42949672951048577
DptCo131unsignedInt 0…42949672951048577
DptCo132unsignedInt 0…42949672951048577
DptCo133unsignedInt 0…42949672951048577
DptCo134unsignedInt 0…42949672951048577
DptCo135unsignedInt 0…42949672951048577
DptCo136unsignedInt 0…42949672951048577
DptCo137unsignedInt 0…42949672951048577
DptCo138unsignedInt 0…42949672951048577
DptCo139unsignedInt 0…42949672951048577
DptCo140unsignedInt 0…42949672951048577
DptCo141unsignedInt 0…42949672951048577
DptCo142unsignedInt 0…42949672951048577
DptCo143unsignedInt 0…42949672951048577
DptCo144unsignedInt 0…42949672951048577
DptCo145unsignedInt 0…42949672951048577
DptCo146unsignedInt 0…42949672951048577
DptCo147unsignedInt 0…42949672951048577
DptCo148unsignedInt 0…42949672951048577
DptCo149unsignedInt 0…42949672951048577
DptCo150unsignedInt 0…42949672951048577
KimFlagsCo1unsignedInt 0…42949672951
KimFlagsCo2unsignedInt 0…42949672950
KimFlagsCo3unsignedInt 0…42949672951
KimFlagsCo4unsignedInt 0…42949672950
KimFlagsCo5unsignedInt 0…42949672951
KimFlagsCo6unsignedInt 0…42949672950
KimFlagsCo7unsignedInt 0…42949672951
KimFlagsCo8unsignedInt 0…42949672950
KimFlagsCo9unsignedInt 0…42949672950
KimFlagsCo10unsignedInt 0…42949672950
KimFlagsCo11unsignedInt 0…42949672950
KimFlagsCo12unsignedInt 0…42949672950
KimFlagsCo13unsignedInt 0…42949672950
KimFlagsCo14unsignedInt 0…42949672950
KimFlagsCo15unsignedInt 0…42949672950
KimFlagsCo16unsignedInt 0…42949672950
KimFlagsCo17unsignedInt 0…42949672950
KimFlagsCo18unsignedInt 0…42949672950
KimFlagsCo19unsignedInt 0…42949672950
KimFlagsCo20unsignedInt 0…42949672950
KimFlagsCo21unsignedInt 0…42949672950
KimFlagsCo22unsignedInt 0…42949672950
KimFlagsCo23unsignedInt 0…42949672950
KimFlagsCo24unsignedInt 0…42949672950
KimFlagsCo25unsignedInt 0…42949672950
KimFlagsCo26unsignedInt 0…42949672950
KimFlagsCo27unsignedInt 0…42949672950
KimFlagsCo28unsignedInt 0…42949672950
KimFlagsCo29unsignedInt 0…42949672950
KimFlagsCo30unsignedInt 0…42949672950
KimFlagsCo31unsignedInt 0…42949672950
KimFlagsCo32unsignedInt 0…42949672950
KimFlagsCo33unsignedInt 0…42949672950
KimFlagsCo34unsignedInt 0…42949672950
KimFlagsCo35unsignedInt 0…42949672950
KimFlagsCo36unsignedInt 0…42949672950
KimFlagsCo37unsignedInt 0…42949672950
KimFlagsCo38unsignedInt 0…42949672950
KimFlagsCo39unsignedInt 0…42949672950
KimFlagsCo40unsignedInt 0…42949672950
KimFlagsCo41unsignedInt 0…42949672950
KimFlagsCo42unsignedInt 0…42949672950
KimFlagsCo43unsignedInt 0…42949672950
KimFlagsCo44unsignedInt 0…42949672950
KimFlagsCo45unsignedInt 0…42949672950
KimFlagsCo46unsignedInt 0…42949672950
KimFlagsCo47unsignedInt 0…42949672950
KimFlagsCo48unsignedInt 0…42949672950
KimFlagsCo49unsignedInt 0…42949672950
KimFlagsCo50unsignedInt 0…42949672950
KimFlagsCo51unsignedInt 0…42949672950
KimFlagsCo52unsignedInt 0…42949672950
KimFlagsCo53unsignedInt 0…42949672950
KimFlagsCo54unsignedInt 0…42949672950
KimFlagsCo55unsignedInt 0…42949672950
KimFlagsCo56unsignedInt 0…42949672950
KimFlagsCo57unsignedInt 0…42949672950
KimFlagsCo58unsignedInt 0…42949672950
KimFlagsCo59unsignedInt 0…42949672950
KimFlagsCo60unsignedInt 0…42949672950
KimFlagsCo61unsignedInt 0…42949672950
KimFlagsCo62unsignedInt 0…42949672950
KimFlagsCo63unsignedInt 0…42949672950
KimFlagsCo64unsignedInt 0…42949672950
KimFlagsCo65unsignedInt 0…42949672950
KimFlagsCo66unsignedInt 0…42949672950
KimFlagsCo67unsignedInt 0…42949672950
KimFlagsCo68unsignedInt 0…42949672950
KimFlagsCo69unsignedInt 0…42949672950
KimFlagsCo70unsignedInt 0…42949672950
KimFlagsCo71unsignedInt 0…42949672950
KimFlagsCo72unsignedInt 0…42949672950
KimFlagsCo73unsignedInt 0…42949672950
KimFlagsCo74unsignedInt 0…42949672950
KimFlagsCo75unsignedInt 0…42949672950
KimFlagsCo76unsignedInt 0…42949672950
KimFlagsCo77unsignedInt 0…42949672950
KimFlagsCo78unsignedInt 0…42949672950
KimFlagsCo79unsignedInt 0…42949672950
KimFlagsCo80unsignedInt 0…42949672950
KimFlagsCo81unsignedInt 0…42949672950
KimFlagsCo82unsignedInt 0…42949672950
KimFlagsCo83unsignedInt 0…42949672950
KimFlagsCo84unsignedInt 0…42949672950
KimFlagsCo85unsignedInt 0…42949672950
KimFlagsCo86unsignedInt 0…42949672950
KimFlagsCo87unsignedInt 0…42949672950
KimFlagsCo88unsignedInt 0…42949672950
KimFlagsCo89unsignedInt 0…42949672950
KimFlagsCo90unsignedInt 0…42949672950
KimFlagsCo91unsignedInt 0…42949672950
KimFlagsCo92unsignedInt 0…42949672950
KimFlagsCo93unsignedInt 0…42949672950
KimFlagsCo94unsignedInt 0…42949672950
KimFlagsCo95unsignedInt 0…42949672950
KimFlagsCo96unsignedInt 0…42949672950
KimFlagsCo97unsignedInt 0…42949672950
KimFlagsCo98unsignedInt 0…42949672950
KimFlagsCo99unsignedInt 0…42949672950
KimFlagsCo100unsignedInt 0…42949672950
KimFlagsCo101unsignedInt 0…42949672951
KimFlagsCo102unsignedInt 0…42949672951
KimFlagsCo103unsignedInt 0…42949672951
KimFlagsCo104unsignedInt 0…42949672951
KimFlagsCo105unsignedInt 0…42949672951
KimFlagsCo106unsignedInt 0…42949672951
KimFlagsCo107unsignedInt 0…42949672951
KimFlagsCo108unsignedInt 0…42949672951
KimFlagsCo109unsignedInt 0…42949672951
KimFlagsCo110unsignedInt 0…42949672951
KimFlagsCo111unsignedInt 0…42949672951
KimFlagsCo112unsignedInt 0…42949672951
KimFlagsCo113unsignedInt 0…42949672951
KimFlagsCo114unsignedInt 0…42949672951
KimFlagsCo115unsignedInt 0…42949672951
KimFlagsCo116unsignedInt 0…42949672951
KimFlagsCo117unsignedInt 0…42949672951
KimFlagsCo118unsignedInt 0…42949672951
KimFlagsCo119unsignedInt 0…42949672951
KimFlagsCo120unsignedInt 0…42949672951
KimFlagsCo121unsignedInt 0…42949672951
KimFlagsCo122unsignedInt 0…42949672951
KimFlagsCo123unsignedInt 0…42949672951
KimFlagsCo124unsignedInt 0…42949672951
KimFlagsCo125unsignedInt 0…42949672951
KimFlagsCo126unsignedInt 0…42949672951
KimFlagsCo127unsignedInt 0…42949672951
KimFlagsCo128unsignedInt 0…42949672951
KimFlagsCo129unsignedInt 0…42949672951
KimFlagsCo130unsignedInt 0…42949672951
KimFlagsCo131unsignedInt 0…42949672951
KimFlagsCo132unsignedInt 0…42949672951
KimFlagsCo133unsignedInt 0…42949672951
KimFlagsCo134unsignedInt 0…42949672951
KimFlagsCo135unsignedInt 0…42949672951
KimFlagsCo136unsignedInt 0…42949672951
KimFlagsCo137unsignedInt 0…42949672951
KimFlagsCo138unsignedInt 0…42949672951
KimFlagsCo139unsignedInt 0…42949672951
KimFlagsCo140unsignedInt 0…42949672951
KimFlagsCo141unsignedInt 0…42949672951
KimFlagsCo142unsignedInt 0…42949672951
KimFlagsCo143unsignedInt 0…42949672951
KimFlagsCo144unsignedInt 0…42949672951
KimFlagsCo145unsignedInt 0…42949672951
KimFlagsCo146unsignedInt 0…42949672951
KimFlagsCo147unsignedInt 0…42949672951
KimFlagsCo148unsignedInt 0…42949672951
KimFlagsCo149unsignedInt 0…42949672951
KimFlagsCo150unsignedInt 0…42949672951
Speed text displayunsignedInt 0…2550
Text wrappingunsignedInt 0…2552
KimAppTypeunsignedInt 0…2550
KimAppIdtextSdaApp
DNS server (if not using DHCP)listdefault gateway
Individual DNS server IP addressipAddress0.0.0.0
General remote access after restartlistas before restart
Remote access for group "Residents" after restartlistas before restart
Remote access for group "Installers" after restartlistas before restart
Remote access via "Quick Connect" after restartlistas before restart
Separator for floating point numberslist'.'
Threshold valueunsignedInt 0…10000
Threshold baselist1
FillUpForNumber5unsignedInt 0…10
FillUpForFlags3unsignedInt 0…10
Notification for changed value onlyunsignedInt 0…10
Add AttachmentunsignedInt 0…10
PrioritylistLow
Number of Notification objectsunsignedInt 0…500
Datapoint typelistBool (1 bit, DPT 1.001)
Filterlistalways create notification
Subjecttext
Texttext
Filtertext
Attachment URLtext
Categorytext
FirmwareVersionlistFirmwareVersion

Version history

ApplicationApp noFingerprintFirst seenSizeFile
Gira S1 7.5 latest$00040A9A2026-11-25700 KBDownload
Gira S1 7.5$00040A9A2026-11-25700 KBDownload
Gira S1 7.5$00040A9A2026-11-25700 KBDownload
Gira S1 7.4$000499212026-11-25632 KBDownload
Gira S1 7.4$000499212026-11-25632 KBDownload
Gira S1 7.4$000499212026-11-25632 KBDownload
Gira S1 7.3$00045F442026-11-25587 KBDownload
Gira S1 7.3$00045F442026-11-25587 KBDownload
Gira S1 7.3$00045F442026-11-25587 KBDownload
Gira S1 6.2$000486492026-11-25410 KBDownload
Gira S1 6.2$000486492026-11-25410 KBDownload
Gira S1 6.2$000486492026-11-25410 KBDownload
Gira S1 5.0$000401FB2026-11-25205 KBDownload
Gira S1 5.0$000401FB2026-11-25205 KBDownload
Gira S1 5.0$000401FB2026-11-25205 KBDownload
Gira S1 4.1$0004EF352026-11-25201 KBDownload
Gira S1 4.1$0004EF352026-11-25201 KBDownload
Gira S1 4.1$0004EF352026-11-25201 KBDownload
Gira S1 3.1$00046CD32026-11-25109 KBDownload
Gira S1 3.1$00046CD32026-11-25109 KBDownload
Gira S1 3.1$00046CD32026-11-25109 KBDownload

About this file

This is the official ETS product database for the GIRA Giersiepen Gira S1 (2089 00), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.

More from GIRA Giersiepen

All GIRA Giersiepen products