KNX Database
GIRA Giersiepen 2070 00 Gira Logic Module

Gira Logic Module 2070 00

GIRA Giersiepen · Order number 2070 00 · Controller

2070 00, Logikmodul 601011

Download .knxprod Gira Logic Module 601011 1.1 · 66 KB

Product

ManufacturerGIRA Giersiepen
Product nameGira Logic Module
Order number2070 00
Product textGira L1
HardwareGira L1
MediumTwisted Pair
Bus current (mA)10
Rail mountedYes
Width (mm)35
Device kindIPEnabled
RegistrationCertified · 2014-07-14
Languagesde-DE, el-GR, en-US, es-ES, fr-FR, it-IT, nb-NO, ru-RU, sv-SE, nl-NL
Catalog entryM-0008_H-GILOMOKX01-16_HP-6010-11-5218-6011-11-9BDF_CI-2070.2000-1
Fingerprint5218
SHA-2568d43335b372ec745a9c3ccd5dba055c43e09bf3d72eee07a4d82db4123c616a9
First seen2026-11-25
Markets40 markets

Application program: Gira Logikmodul 601011 1.1

Application number$6010
Version1.1
Mask versionMV-07B0 (System B)
KNX Data SecureNo
Minimum ETS version4.0
Parameters7
Group objects42
Group objects (42)
NoNameFunctionSizeDPTFlags
1DeviceReady1 Bit1.11 stateCRT
2DeviceState1 Byte5.10 counter pulses (0..255)CRT
3DeviceReboot1 Bit1.15 resetCW
4DeviceDate3 Bytes11.1 dateCR
4DeviceDate3 Bytes11.1 dateCWUI
5DeviceTime3 Bytes10.1 time of dayCR
5DeviceTime3 Bytes10.1 time of dayCWUI
6DeviceDST1 Bit1.2 booleanCR
7DeviceUptime4 Bytes13.100 time lag (s)CRT
50KNXProgramming Mode1 Bit1.1 switchCWU
51KNXProgramming Mode State1 Bit1.1 switchCRT
60KNXBus State1 Bit1.11 stateCRT
4400Timer 1Trigger1 Bit1.17 triggerCT
4401Timer 2Trigger1 Bit1.17 triggerCT
4402Timer 3Trigger1 Bit1.17 triggerCT
4403Timer 4Trigger1 Bit1.17 triggerCT
4404Timer 5Trigger1 Bit1.17 triggerCT
4405Timer 6Trigger1 Bit1.17 triggerCT
4406Timer 7Trigger1 Bit1.17 triggerCT
4407Timer 8Trigger1 Bit1.17 triggerCT
4408Timer 9Trigger1 Bit1.17 triggerCT
4409Timer 10Trigger1 Bit1.17 triggerCT
4500Scene Set 1Control1 Byte18.1 scene controlCWT
4501Scene Set 2Control1 Byte18.1 scene controlCWT
4502Scene Set 3Control1 Byte18.1 scene controlCWT
4503Scene Set 4Control1 Byte18.1 scene controlCWT
4504Scene Set 5Control1 Byte18.1 scene controlCWT
4505Scene Set 6Control1 Byte18.1 scene controlCWT
4506Scene Set 7Control1 Byte18.1 scene controlCWT
4507Scene Set 8Control1 Byte18.1 scene controlCWT
4508Scene Set 9Control1 Byte18.1 scene controlCWT
4509Scene Set 10Control1 Byte18.1 scene controlCWT
4510Scene Set 11Control1 Byte18.1 scene controlCWT
4511Scene Set 12Control1 Byte18.1 scene controlCWT
4512Scene Set 13Control1 Byte18.1 scene controlCWT
4513Scene Set 14Control1 Byte18.1 scene controlCWT
4514Scene Set 15Control1 Byte18.1 scene controlCWT
4515Scene Set 16Control1 Byte18.1 scene controlCWT
4516Scene Set 17Control1 Byte18.1 scene controlCWT
4517Scene Set 18Control1 Byte18.1 scene controlCWT
4518Scene Set 19Control1 Byte18.1 scene controlCWT
4519Scene Set 20Control1 Byte18.1 scene controlCWT
Parameters (7)
ParameterTypeDefault
Device IDtextGILOMOKX0110
Zeige NeustartunsignedInt 0…10
ZeitmoduslistKeiner
Zeige KNX ZuständeunsignedInt 0…10
Zeige TimerunsignedInt 0…10
Zeige SzenenunsignedInt 0…10
PID_HARDWARE_TYPElist

Application program: Application Program 2 1.1

Application number$6011
Version1.1
Mask versionMV-07B0 (System B)
KNX Data SecureNo
Minimum ETS version4.0
Parameters0
Group objects0
Group objects (0)
NoNameFunctionSizeDPTFlags
Parameters (0)
ParameterTypeDefault

Version history

ApplicationApp noFingerprintFirst seenSizeFile
Gira L1 2.0 latest$60104D552026-11-25203 KBDownload
Gira Logic Module 601011 1.1$601052182026-11-2566 KBDownload

About this file

This is the official ETS product database for the GIRA Giersiepen Gira Logic Module (2070 00), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.

More from GIRA Giersiepen

All GIRA Giersiepen products