KNX Database

GWA9322

GEWISS · Order number GWA9322 · Lighting Control/Regulation › Dimmer 2 outputs

Download .knxprod KNX Universal dimming actuator 2 ch. 300W [SECURE] S 1.0 1.0 · 182 KB

Product

ManufacturerGEWISS
Product nameGWA9322
Order numberGWA9322
Product textKNX Universal dimming actuator 2 ch. 300W [SECURE]
HardwareKNX Universal dimming actuator 2 ch. 300W [SECURE]
MediumTwisted Pair
Bus current (mA)10
Rail mountedYes
Width (mm)72
RegistrationCertified · 2025-02-10
Languagesen-US, de-DE, es-ES, it-IT
Catalog entryM-0019_H-A9322-0_HP-5402-10-842E_CI-GWA9322-0
Fingerprint842E
SHA-256670814d4a89cd006659815e1825eea8fc0f5444fb118107694e5d10700d45186
First seen2026-11-25
Markets59 markets

Application program: KNX Universal dimming actuator 2 ch. 300W [SECURE] S 1.0 1.0

Application number$5402
Version1.0
Mask versionMV-07B0 (System B)
KNX Data SecureYes
Minimum ETS version5.0
Parameters341
Group objects88
Group objects (88)
NoNameFunctionSizeDPTFlags
1Ch.1 - SwitchOn/Off1 Bit1.1 switchCW
2Ch.1 - Brightness dimmingIncrease/Decrease4 Bit3.7 dimming controlCW
3Ch.1 - Command value% Value1 Byte5.1 percentage (0..100%)CW
4Ch.1 - Timed switchStart/Stop1 Bit1.10 start/stopCW
5Ch.1 - BlinkingSwitching On/Off1 Bit1.1 switchCW
6Ch.1 - SceneExecute/Store1 Byte18.1 scene controlCW
6Ch.1 - SceneExecute1 Byte17.1 scene numberCW
7Ch.1 - Priority commandOn/Off forced positioning2 Bit2.1 switch controlCW
8Ch.1 - BlockSwitching On/Off1 Bit1.3 enableCW
9Ch.1 - Logic input 1Logic1 Bit1.2 booleanCW
10Ch.1 - Logic input 2Logic1 Bit1.2 booleanCW
11Ch.1 - Logic input 3Logic1 Bit1.2 booleanCW
12Ch.1 - Logic input 4Logic1 Bit1.2 booleanCW
13Ch.1 - Logic input 5Logic1 Bit1.2 booleanCW
14Ch.1 - Logic input 6Logic1 Bit1.2 booleanCW
15Ch.1 - Logic input 7Logic1 Bit1.2 booleanCW
16Ch.1 - Logic input 8Logic1 Bit1.2 booleanCW
17Ch.1 - StatusOn/Off1 Bit1.1 switchCR
17Ch.1 - StatusOn/Off1 Bit1.1 switchCRT
18Ch.1 - Brightness value% Value1 Byte5.1 percentage (0..100%)CR
18Ch.1 - Brightness value% Value1 Byte5.1 percentage (0..100%)CRT
19Ch.1 - Logical operation outcomeLogic1 Bit1.2 booleanCRT
20Ch.1 - Stairs light activation timeValue in seconds2 Bytes7.5 time (s)CW
21Ch.1 - Scene storing enablingEnable/Disable1 Bit1.3 enableCW
22Ch.1 - Slave mode enablingEnable/Disable1 Bit1.3 enableCW
23Ch.1 - Slave brightness dimmingIncrease/Decrease4 Bit3.7 dimming controlCW
24Ch.1 - Slave value command% Value1 Byte5.1 percentage (0..100%)CW
25Ch.1 - CounterValue 0 .. 65535 [s]2 Bytes7.5 time (s)CRT
25Ch.1 - CounterValue 0 .. 65535 [min]2 Bytes7.6 time (min)CRT
25Ch.1 - CounterValue 0 .. 65535 [h]2 Bytes7.7 time (h)CRT
25Ch.1 - CounterValue 0 .. 65535 [s]2 Bytes7.5 time (s)CR
25Ch.1 - CounterValue 0 .. 65535 [min]2 Bytes7.6 time (min)CR
25Ch.1 - CounterValue 0 .. 65535 [h]2 Bytes7.7 time (h)CR
26Ch.1 - Counter overflowOverflow state1 Bit1.2 booleanCRT
27Ch.1 - Counter value sending triggerCounter value transmission1 Bit1.17 triggerCW
28Ch.1 - Counter resetValue reset1 Bit1.17 triggerCW
29Ch.1 - 230V voltage alarmTrue/False1 Bit1.5 alarmCR
29Ch.1 - 230V voltage alarmTrue/False1 Bit1.5 alarmCRT
30Ch.1 - Output overload alarmTrue/False1 Bit1.5 alarmCR
30Ch.1 - Output overload alarmTrue/False1 Bit1.5 alarmCRT
31Ch.1 - Overheat alarmTrue/False1 Bit1.5 alarmCR
31Ch.1 - Overheat alarmTrue/False1 Bit1.5 alarmCRT
32Ch.1 - Local button function enablingEnable/Disable1 Bit1.3 enableCW
33Ch.1 - Local button function enabling statusEnabled/Disabled1 Bit1.3 enableCRT
34Ch.2 - SwitchOn/Off1 Bit1.1 switchCW
35Ch.2 - Brightness dimmingIncrease/Decrease4 Bit3.7 dimming controlCW
36Ch.2 - Command value% Value1 Byte5.1 percentage (0..100%)CW
37Ch.2 - Timed switchStart/Stop1 Bit1.10 start/stopCW
38Ch.2 - BlinkingSwitching On/Off1 Bit1.1 switchCW
39Ch.2 - SceneExecute/Store1 Byte18.1 scene controlCW
39Ch.2 - SceneExecute1 Byte17.1 scene numberCW
40Ch.2 - Priority commandOn/Off forced positioning2 Bit2.1 switch controlCW
41Ch.2 - BlockSwitching On/Off1 Bit1.3 enableCW
42Ch.2 - Logic input 1Logic1 Bit1.2 booleanCW
43Ch.2 - Logic input 2Logic1 Bit1.2 booleanCW
44Ch.2 - Logic input 3Logic1 Bit1.2 booleanCW
45Ch.2 - Logic input 4Logic1 Bit1.2 booleanCW
46Ch.2 - Logic input 5Logic1 Bit1.2 booleanCW
47Ch.2 - Logic input 6Logic1 Bit1.2 booleanCW
48Ch.2 - Logic input 7Logic1 Bit1.2 booleanCW
49Ch.2 - Logic input 8Logic1 Bit1.2 booleanCW
50Ch.2 - StatusOn/Off1 Bit1.1 switchCR
50Ch.2 - StatusOn/Off1 Bit1.1 switchCRT
51Ch.2 - Brightness value% Value1 Byte5.1 percentage (0..100%)CR
51Ch.2 - Brightness value% Value1 Byte5.1 percentage (0..100%)CRT
52Ch.2 - Logical operation outcomeLogic1 Bit1.2 booleanCRT
53Ch.2 - Stairs light activation timeValue in seconds2 Bytes7.5 time (s)CW
54Ch.2 - Scene storing enablingEnable/Disable1 Bit1.3 enableCW
55Ch.2 - Slave mode enablingEnable/Disable1 Bit1.3 enableCW
56Ch.2 - Slave brightness dimmingIncrease/Decrease4 Bit3.7 dimming controlCW
57Ch.2 - Slave value command% Value1 Byte5.1 percentage (0..100%)CW
58Ch.2 - CounterValue 0 .. 65535 [s]2 Bytes7.5 time (s)CRT
58Ch.2 - CounterValue 0 .. 65535 [min]2 Bytes7.6 time (min)CRT
58Ch.2 - CounterValue 0 .. 65535 [h]2 Bytes7.7 time (h)CRT
58Ch.2 - CounterValue 0 .. 65535 [s]2 Bytes7.5 time (s)CR
58Ch.2 - CounterValue 0 .. 65535 [min]2 Bytes7.6 time (min)CR
58Ch.2 - CounterValue 0 .. 65535 [h]2 Bytes7.7 time (h)CR
59Ch.2 - Counter overflowOverflow state1 Bit1.2 booleanCRT
60Ch.2 - Counter value sending triggerCounter value transmission1 Bit1.17 triggerCW
61Ch.2 - Counter resetValue reset1 Bit1.17 triggerCW
62Ch.2 - 230V voltage alarmTrue/False1 Bit1.5 alarmCR
62Ch.2 - 230V voltage alarmTrue/False1 Bit1.5 alarmCRT
63Ch.2 - Output overload alarmTrue/False1 Bit1.5 alarmCR
63Ch.2 - Output overload alarmTrue/False1 Bit1.5 alarmCRT
64Ch.2 - Overheat alarmTrue/False1 Bit1.5 alarmCR
64Ch.2 - Overheat alarmTrue/False1 Bit1.5 alarmCRT
65Ch.2 - Local button function enablingEnable/Disable1 Bit1.3 enableCW
66Ch.2 - Local button function enabling statusEnabled/Disabled1 Bit1.3 enableCRT
Parameters (172)
ParameterTypeDefault
PID_HARDWARE_TYPE_PARAMETERlist
Channel 1listenable
Channel 2listenable
Alarms and status information transmission delay at startlistfrom 1 to 15 (depending on physical address)
PARAM_DO_MASTER_RESETlistAPP_FIRST_BOOT
Connected load control typelistleading edge
Connected load trigger typelistsoft start
- Dwell time at 100% for load trigger [ms]unsignedInt 1…655352000
Maximum dimming thresholdlist100%
Minimum dimming thresholdlist1%
Brightness reaching for on/off, stairs light, forcing, block, blinking, slavelistwith jump to value
- Dimming ramp 0%-100% speedlist4 s
Channel status at bus voltage recoverylistas before voltage drop
- Channel brightness at bus voltage recoverylist0%
Channel status at 230V voltage recoverylistfollows last command received
- Channel brightness at 230V voltage recoverylist0%
Local push button behaviourlistsingle push button dimmer test
- Activate/deactivate local button operation from buslistdisable
Device overheating alarm feedbacklistsending on change
230V voltage alarm feedbacklistsending on change
Overload alarm warninglistsending on change
Switching on brightness valuelistlast value when ON (memory)
- Channel switching ON brightnesslist100%
Delay at switch ONlistdisable
- Delay time at switch ONlist1 s
Delay at switch OFFlistdisabled
- Delay time at switch OFFlist1 s
Stairs light functionlistdeactivated
Brightness value during timinglistlast value when ON (memory)
- Brightness during timinglist100%
Activation time [hours]unsignedInt 0…230
Activation time [minutes]unsignedInt 0…591
Activation time [seconds]unsignedInt 0…590
Delay on timed activationlistdisable
- Timed activation delay timelist1 s
Prewarning timelistdisabled
Timing stop functionlistdisable
Command of activation during timinglistrestart
- Multiplicative factor maximum valueunsignedInt 2…55
Absolute or relative brightness dimming command during timinglistit's executed and continues timing
Stairs light activation time setting from buslistdisable
Dimming behaviour at minimum threshold reachingliststop dimming at minimum threshold
Relative dimming speed between 0% and 50%list3 s
Relative dimming speed between 50% and 100%list3 s
Brightness reaching with command valuelistwith jump to value
- Dimming ramp 0%-100% speed for command valuelist4 s
Delay at start with command valuelistdisable
- Switch on delay time with command valuelist1 s
Behaviour with command value < minimum threshold and channel ONlistswitching off (0%)
Delay at switching off with command value < minimum thresholdlistdisabled
- Switch off delay time with command value < minimum thresholdlist1 s
Logic functionlistdisable
Logic inputs numberlist1
Operation between logic inputslistAND
The logic input value stands forlistnew logic input
Execute logical operation with the objectlistswitching
Logical operation to executelistAND
Switching commands (on/off)listindependent from logic function
Brightness relative dimming commandslistindependent from logic function
Brightness absolute dimming commandslistindependent from logic function
Timed switch commandslistindependent from logic function
Blinking commandslistindependent from logic function
Scene commandslistindependent from logic function
NOT operation for logic input 1listdisable
NOT operation for logic input 2listdisable
NOT operation for logic input 3listdisable
NOT operation for logic input 4listdisable
NOT operation for logic input 5listdisable
NOT operation for logic input 6listdisable
NOT operation for logic input 7listdisable
NOT operation for logic input 8listdisable
Logic input 1 value at downloadlist"0" value
Logic input 2 value at downloadlist"0" value
Logic input 3 value at downloadlist"0" value
Logic input 4 value at downloadlist"0" value
Logic input 5 value at downloadlist"0" value
Logic input 6 value at downloadlist"0" value
Logic input 7 value at downloadlist"0" value
Logic input 8 value at downloadlist"0" value
Logic input 1 value at bus voltage recoverylistas before voltage drop
Logic input 2 value at bus voltage recoverylistas before voltage drop
Logic input 3 value at bus voltage recoverylistas before voltage drop
Logic input 4 value at bus voltage recoverylistas before voltage drop
Logic input 5 value at bus voltage recoverylistas before voltage drop
Logic input 6 value at bus voltage recoverylistas before voltage drop
Logic input 7 value at bus voltage recoverylistas before voltage drop
Logic input 8 value at bus voltage recoverylistas before voltage drop
Logic function outcome feedbacklistdisabled
Scenes functionlistdisable
Scene number 1listunassigned
Brightness starting value for scene 1list100%
Scene 1 execution brightness reachinglistwith jump to value
- Dimming ramp 0%-100% speed for scene 1 executionlist4 s
Scene number 2listunassigned
Brightness starting value for scene 2list100%
Scene 2 execution brightness reachinglistwith jump to value
- Dimming ramp 0%-100% speed for scene 2 executionlist4 s
Scene number 3listunassigned
Brightness starting value for scene 3list100%
Scene 3 execution brightness reachinglistwith jump to value
- Dimming ramp 0%-100% speed for scene 3 executionlist4 s
Scene number 4listunassigned
Brightness starting value for scene 4list100%
Scene 4 execution brightness reachinglistwith jump to value
- Dimming ramp 0%-100% speed for scene 4 executionlist4 s
Scene number 5listunassigned
Brightness starting value for scene 5list100%
Scene 5 execution brightness reachinglistwith jump to value
- Dimming ramp 0%-100% speed for scene 5 executionlist4 s
Scene number 6listunassigned
Brightness starting value for scene 6list100%
Scene 6 execution brightness reachinglistwith jump to value
- Dimming ramp 0%-100% speed for scene 6 executionlist4 s
Scene number 7listunassigned
Brightness starting value for scene 7list100%
Scene 7 execution brightness reachinglistwith jump to value
- Dimming ramp 0%-100% speed for scene 7 executionlist4 s
Scene number 8listunassigned
Brightness starting value for scene 8list100%
Scene 8 execution brightness reachinglistwith jump to value
- Dimming ramp 0%-100% speed for scene 8 executionlist4 s
Scenes storing enablinglistenable
Blinking functionlistdeactivated
Activation valuelist"1" value
Activation time [minutes]unsignedInt 0…590
Activation time [seconds]unsignedInt 0…595
Deactivation time [hours]unsignedInt 0…230
Deactivation time [minutes]unsignedInt 0…590
Deactivation time [seconds]unsignedInt 0…595
Channel brightness during activation timelistcurrent brightness
- % Valuelist100%
Channel status at blinking mode deactivationlistno change
Turn on the blinking mode at bus voltage restorelistno
Forced positioning functionlistdisable
Brightness value at ON forcing activationlistswitching ON brightness value
- Channel brightness at ON forcing activationlist100%
Channel status at forcing endlistfollows last command received
- Brightness at forcing endinglist100%
Forcing status at bus voltage recoverylistas before voltage drop
Block functionlistdisable
Block activation valuelist"1" value
Channel status with active blocklistmaximum dimming threshold value
- Channel brightness with active blocklist100%
Channel status at block deactivation endlistfollows last command received
- Brightness at block endinglist100%
Block on download functionlistdisable
Block status at bus voltage recoverylistas before voltage drop
Slave modelistdisable
Monitoring time [minutes]unsignedInt 1…605
Channel status in safety modelistno change
- Channel brightness in safety modelist100%
Slave mode value at downloadlistdisable
Slave mode value at bus voltage recoverylistas before voltage drop
Channel status at slave mode deactivationlistfollows last command received
- Channel brightness at slave mode deactivationlist100%
Counter functionlistdisable
Increase the count iflistoutput is ON (brightness > 0%)
Counter value formatlist2 bytes (hours)
Overflow value [seconds]unsignedInt 0…6553565535
Overflow value [minutes]unsignedInt 0…6553565535
Overflow value [hours]unsignedInt 0…6553565535
Counter value overflow feedbacklistdisable
Counter value sending conditionlistsending on demand only
Counter value minimum change for sending valueunsignedInt 1…10010
Counter value sending period [seconds]unsignedInt 1…25515
Counter reset objectlistdisable
Status information transmissionlistsending on change
Absolute brightness value transmissionlistsending on change
- Brightness minimum change for sending valuelist5%
- Minimum interval between successive brightness value feedbackslist1,5 seconds
Status information transmission at bus voltage recoverylistenable
The outcome of the operation with logic inputs stands forlistnew logic input

Version history

ApplicationApp noFingerprintFirst seenSizeFile
KNX Universal dimming actuator 2 ch. 300W [SECURE] S 1.0 1.0 latest$5402842E2026-11-25182 KBDownload

About this file

This is the official ETS product database for the GEWISS GWA9322 (GWA9322), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.

More from GEWISS

All GEWISS products