KNX MultiLight 44001
function Technology · Order number 44001 · Actuator/Sensor › Multipurpose
Download .knxprod KNX MultiLight 1.0 · 83 KB
Product
| Manufacturer | function Technology |
|---|---|
| Product name | KNX MultiLight |
| Order number | 44001 |
| Hardware | KNX MultiLight |
| Medium | Twisted Pair |
| Bus current (mA) | 10 |
| Rail mounted | No |
| Registration | Registered |
| Languages | de-DE, en-US |
| Catalog entry | M-0088_H-KNX.20MultiLight-1-O00C5_HP-1100-10-1B84-O00C5_CI-44001-1 |
| Fingerprint | 1B84 |
| SHA-256 | e058c074a273fe567c69bcfd06a84b495ab15ae0307342225264de866577c752 |
| First seen | 2026-11-25 |
| Markets | 59 markets |
Application program: KNX MultiLight 1.0
| Application number | $1100 |
|---|---|
| Version | 1.0 |
| Mask version | MV-0705 (7.5) |
| KNX Data Secure | No |
| Parameters | 137 |
| Group objects | 44 |
Group objects (44)
| No | Name | Function | Size | DPT | Flags |
|---|---|---|---|---|---|
| 0 | Device: Self-Test status | 1 Bit | CRT | ||
| 1 | Panel: Shutter operation - Stop/Step | 1 Bit | CT | ||
| 2 | Panel: Shutter operation - Up/Down | 1 Bit | CT | ||
| 3 | Movement: General | 1 Bit | CT | ||
| 4 | Movement: Local | 1 Bit | CT | ||
| 5 | Lux sensor: Current value (lux) | 2 Bytes | CRW | ||
| 6 | Lux sensor: Lux threshold switch | 1 Bit | CT | ||
| 7 | Thermostat: Actual temperature | 2 Bytes | CRT | ||
| 8 | Thermostat: External temperature | 2 Bytes | CWT | ||
| 9 | Thermostat: Base setpoint | 2 Bytes | CRWT | ||
| 9 | Thermostat: Base setpoint | 2 Bytes | CRT | ||
| 10 | Thermostat: Actual setpoint | 2 Bytes | CRT | ||
| 11 | Thermostat: Local adjustment of temp offset | 2 Bytes | CRWT | ||
| 12 | Thermostat: Comfort mode | 1 Bit | CW | ||
| 13 | Thermostat: Night mode | 1 Bit | CW | ||
| 14 | Thermostat: Frost/Heat protecting mode | 1 Bit | CW | ||
| 15 | Thermostat: Control value basic heating Switch | 1 Bit | CRT | ||
| 16 | Thermostat: Control value basic heating Continous | 1 Byte | CRT | ||
| 17 | Thermostat: Control value basic heating Feedback | 1 Bit | CRT | ||
| 18 | Thermostat: Control value add. heating Switch | 1 Bit | CRT | ||
| 19 | Thermostat: Control value basic cooling Switch | 1 Bit | CRT | ||
| 20 | Thermostat: Control value basic cooling Continous | 1 Byte | CRT | ||
| 21 | Thermostat: Control value basic cooling Feedback | 1 Bit | CRT | ||
| 22 | Thermostat: Control value add. cooling Switch | 1 Bit | CRT | ||
| 23 | Relay: Continuous heating/cooling | 1 Bit | CRT | ||
| 23 | Relay: Switch heating/cooling | 1 Bit | CW | ||
| 23 | Relay: Switch | 1 Bit | CW | ||
| 24 | Relay: Force operation | 1 Bit | CW | ||
| 25 | Relay: Disable staircase function | 1 Bit | CW | ||
| 25 | Relay: Disable delay function | 1 Bit | CW | ||
| 26 | Relay: Change duration | 2 Bytes | CRW | ||
| 27 | Relay: Logic OR | 1 Bit | CW | ||
| 27 | Relay: Logic AND | 1 Bit | CW | ||
| 28 | Relay: Status switch | 1 Bit | CRT | ||
| 29 | Binary input 1: Short operation - Switch | 1 Bit | CWTU | ||
| 29 | Binary input 1: Short operation - Stop/Step | 1 Bit | CWTU | ||
| 30 | Binary input 1: Switch | 1 Bit | CWTU | ||
| 30 | Binary input 1: Long operation - Up/Down | 1 Bit | CWTU | ||
| 30 | Binary input 1: Long operation - Dimming | 4 Bit | CWTU | ||
| 31 | Binary input 2: Short operation - Stop/Step | 1 Bit | CWTU | ||
| 31 | Binary input 2: Short operation - Switch | 1 Bit | CWTU | ||
| 32 | Binary input 2: Switch | 1 Bit | CWTU | ||
| 32 | Binary input 2: Long operation - Up/Down | 1 Bit | CWTU | ||
| 32 | Binary input 2: Long operation - Dimming | 4 Bit | CWTU |
Parameters (69)
| Parameter | Type | Default |
|---|---|---|
| Cyclic sending status of device (Hours, 0 = Disable) | unsignedInt 0…24 | 0 |
| ProcessID | unsignedInt 0…255 | 254 |
| Activation user panel | list | Disable |
| Recovery time (Min.) | unsignedInt 1…255 | 20 |
| Reaction at start of detection | list | On |
| Cyclic sending On commands (Min., 0 = Disable) | unsignedInt 0…255 | 0 |
| Reaction at end of detection | list | Off |
| Separate Movement Local object | list | Disable |
| Lighting dependend switching for Movement Local | list | Disable |
| PIR sensitivity (20 highest, 100 lowest sensitivity) | unsignedInt 20…100 | 40 |
| High threshold value (lux) | unsignedInt 100…5000 | 1200 |
| Hysteresis for lower value (lux) | unsignedInt 50…2000 | 700 |
| Action above high threshold value | list | Off |
| Action below low threshold value (High threshold value - Hysteresis) | list | On |
| Switch on delay (Seconds, 0 = Disable) | unsignedInt 0…255 | 60 |
| Switch off delay (Seconds, 0 = Disable) | unsignedInt 0…255 | 240 |
| Cyclic sending threshold switch (Min., 0 = Disable) | unsignedInt 0…255 | 0 |
| Function | list | Heating and cooling mode |
| Sending of temperature on 0,5K change and cyclic (min., 0=Cyclic disable) | unsignedInt 0…255 | 0 |
| Base setpoint in °C | signedInt 15…35 | 21 |
| Base setpoint change by object | list | Disable |
| Permanent Note: Read manual before enabling | list | Disable |
| Reduced heating in standby mode in 0.1K | signedInt -100…0 | -10 |
| Reduced heating in night mode in 0.1K | signedInt -100…0 | -30 |
| Increased cooling in standby mode in 0.1K | signedInt 0…100 | 10 |
| Increased cooling in night mode in 0.1K | signedInt 0…100 | 30 |
| Deadzone between heating and cooling in 0.1K | signedInt 1…70 | 20 |
| Adjustment of internal temperature sensor in 0.1K | signedInt -128…127 | 0 |
| Mix of external temperature to the regulator in % | unsignedInt 0…100 | 0 |
| Scale of local temperature adjustment in user panel | list | Step 1K (+/- 3K) |
| Limit upper level | list | +1.5K |
| Limit upper level | list | +3K |
| Limit lower level | list | -1.5K |
| Limit lower level | list | -3K |
| Type of control for basic heating | list | Switch control |
| Time constant | list | Hot-water heating (5 K / 150 min) |
| Proportional range in 0.1K | signedInt 10…100 | 50 |
| Reset time in min. (0=Disable) | unsignedInt 0…255 | 100 |
| Reset time in min. (0=Disable) | unsignedInt 0…255 | 150 |
| Sending of Control value at Change in % (0=Disable) | unsignedInt 0…100 | 10 |
| Low hysteresis in 0.1K | signedInt 1…30 | 5 |
| Additional heating | list | Disable |
| Stage offset from basic to additional stage in 0.1K | signedInt -127…-10 | -20 |
| Type of control for basic cooling | list | Switch control |
| Time constant | list | Cooling ceiling (5 K / 240 min) |
| High hysteresis in 0.1K | signedInt 1…30 | 5 |
| Additional cooling | list | Disable |
| Stage offset from basic to additional stage in 0.1K | signedInt 10…127 | 20 |
| Function | list | Switching actuator |
| Addition function | list | Disable |
| Relay type | list | Normally open (relay inverted) |
| Valve actuator type | list | Normally open (relay inverted) |
| Type of telegram for control | list | Switch (1bit) |
| Factor (0 = Disable) | unsignedInt 0…255 | 0 |
| PWM cycle time (min) | unsignedInt 5…255 | 5 |
| Time | list | 1 min |
| Automatic valve purge | list | Disable |
| Days between automatic valve purge (days) | unsignedInt 5…30 | 5 |
| Duration of staircase function (min) | unsignedInt 1…255 | 20 |
| Possibility to switch off the relay from bus | list | Disable |
| Logic | list | Disable |
| Forced operation | list | Relay on |
| Function | list | Switch |
| Operation | list | Rising - Toggle |
| Reaction short operation | list | Toggle |
| Reaction short operation | list | Stop/Toggle Up/Down |
| Reaction long operation | list | Up |
| Reaction long operation | list | Dim brighter/darker |
| Reaction long operation | list | Toggle Up/Down |
Version history
| Application | App no | Fingerprint | First seen | Size | File |
|---|---|---|---|---|---|
| KNX MultiLight 1.0 latest | $1100 | 1B84 | 2026-11-25 | 83 KB | Download |
About this file
This is the official ETS product database for the function Technology KNX MultiLight (44001), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.