pirios 180 KNX Feuchtigkeitsschutz 44180.KNX.xx
Feller · Order number 44180.KNX.xx · Phys. Sensoren › Bewegungsmelder
Download .knxprod pirios 180 / basic digi V2.1 2.1 · 85 KB
Product
| Manufacturer | Feller |
|---|---|
| Product name | pirios 180 KNX Feuchtigkeitsschutz |
| Order number | 44180.KNX.xx |
| Hardware | pirios 180 KNX |
| Medium | Twisted Pair |
| Rail mounted | No |
| Registration | Certified |
| Languages | de-DE, fr-FR |
| Catalog entry | M-001E_H-30.20.2F.2F.2044180.2EKNX.2Exx-1_HP-4418-21-C5E2_CI-44180.2EKNX.2Exx-1 |
| Fingerprint | C5E2 |
| SHA-256 | 5edc8a8cf1cd92a1f2ea9bd0ac304201bd334a416117e2df78e51a2f0457305a |
| First seen | 2026-11-25 |
| Markets | Switzerland |
Application program: pirios 180 / basic digi V2.1 2.1
| Application number | $4418 |
|---|---|
| Version | 2.1 |
| Mask version | MV-0701 (7.1) |
| KNX Data Secure | No |
| Parameters | 121 |
| Group objects | 93 |
Group objects (93)
| No | Name | Function | Size | DPT | Flags |
|---|---|---|---|---|---|
| 0 | Ausgang Licht | EIN/AUS, Schalten | 1 Bit | CWTU | |
| 0 | Object 1 | EIN/AUS, Schalten | 1 Bit | CRWTU | |
| 1 | Object 2 | 1 Bit | CRWTU | ||
| 1 | Ausgang Licht, Szene | senden | 1 Byte | CWTU | |
| 2 | Ausgang HLK | EIN/AUS, Schalten | 1 Bit | CWTU | |
| 2 | Object 3 | EIN/AUS, Schalten | 1 Bit | CRWTU | |
| 3 | Object 4 | 1 Bit | CRWTU | ||
| 3 | Status Licht | synchronisieren | 1 Bit | CWU | |
| 4 | Linker Sensor | deaktivieren | 1 Bit | CW | |
| 5 | Rechter Sensor | deaktivieren | 1 Bit | CW | |
| 6 | Object 7 | 1 Bit | CRWTU | ||
| 7 | Ausgang Licht, Sperrung | sperren | 1 Bit | CWU | |
| 7 | Object 8 | sperren | 1 Bit | CRWTU | |
| 8 | Ausgang Licht, Freigabe | freigeben | 1 Bit | CWU | |
| 8 | Object 9 | freigeben | 1 Bit | CRWTU | |
| 9 | Ausgang HLK, Sperrung | sperren | 1 Bit | CWU | |
| 9 | Object 10 | sperren | 1 Bit | CRWTU | |
| 10 | Ausgang HLK, Freigabe | freigeben | 1 Bit | CWU | |
| 10 | Object 11 | freigeben | 1 Bit | CRWTU | |
| 11 | Object 12 | 1 Bit | CRWTU | ||
| 12 | Object 13 | 1 Bit | CRWTU | ||
| 13 | Object 14 | 1 Bit | CRWTU | ||
| 14 | Object 15 | 1 Bit | CRWTU | ||
| 15 | Master-Slave | triggern | 1 Bit | CWTU | |
| 15 | Object 16 | triggern | 1 Bit | CRWTU | |
| 16 | Object 17 | 1 Bit | CRWTU | ||
| 16 | Sub Master-Slave | triggern | 1 Bit | CWTU | |
| 17 | Object 18 | 1 Bit | CRWTU | ||
| 17 | Helligkeitsverbund | triggern | 1 Bit | CWTU | |
| 18 | Object 19 | 1 Bit | CRWTU | ||
| 19 | Object 20 | 1 Bit | CRWTU | ||
| 20 | Object 21 | 1 Bit | CRWTU | ||
| 20 | Taster extern | schalten | 1 Bit | CWTU | |
| 21 | Object 22 | 1 Bit | CRWTU | ||
| 21 | Lichtszene | empfangen | 1 Byte | CWU | |
| 22 | Object 23 | 1 Bit | CRWTU | ||
| 23 | Object 24 | 1 Bit | CRWTU | ||
| 24 | Object 25 | 1 Bit | CRWTU | ||
| 25 | Dämmerung | hell/dunkel | 1 Bit | CWTU | |
| 25 | Object 26 | hell/dunkel | 1 Bit | CRWTU | |
| 26 | Object 27 | 1 Bit | CRWTU | ||
| 26 | Helligkeitswert (2Byte) | Wert senden | 2 Bytes | CWTU | |
| 27 | Gehtest | in Testmodus setzen | 1 Bit | CWU | |
| 27 | Object 28 | in Testmodus setzen | 1 Bit | CRWTU | |
| 28 | Object 29 | 1 Bit | CRWTU | ||
| 29 | Object 30 | 1 Bit | CRWTU | ||
| 29 | Meldung, Freigabe | freigeben | 1 Bit | CWU | |
| 30 | Object 31 | 1 Bit | CRWTU | ||
| 30 | Meldung | melden | 1 Bit | CWTU | |
| 31 | Object 32 | 1 Bit | CRWTU | ||
| 31 | Meldung, Quittierung | quittieren | 1 Bit | CWU | |
| 32 | Object 33 | 1 Bit | CRWTU | ||
| 32 | Meldung, Lebenszeichen | zyklisch senden | 1 Bit | CWTU | |
| 33 | Object 34 | 1 Bit | CRWTU | ||
| 34 | Object 35 | 1 Bit | CRWTU | ||
| 35 | Object 36 | 1 Bit | CRWTU | ||
| 36 | Object 37 | 1 Byte | CRWTU | ||
| 37 | Object 38 | 1 Byte | CRWTU | ||
| 38 | Object 39 | 1 Byte | CRWTU | ||
| 39 | Object 40 | 1 Byte | CRWTU | ||
| 39 | Remote Helligkeitsschwelle | Wert setzen | 2 Bytes | CWU | |
| 40 | Object 41 | 1 Byte | CRWTU | ||
| 40 | Remote Ausschaltverzögerung Licht | Wert setzen | 2 Bytes | CWU | |
| 41 | Object 42 | 1 Byte | CRWTU | ||
| 41 | Remote Auschaltverzögerung HLK | Wert setzen | 2 Bytes | CWU | |
| 42 | Object 43 | 1 Byte | CRWTU | ||
| 43 | Object 44 | 1 Byte | CRWTU | ||
| 44 | Object 45 | 1 Byte | CRWTU | ||
| 45 | Object 46 | 1 Byte | CRWTU | ||
| 46 | Object 47 | 1 Bit | CRWTU | ||
| 47 | Object 48 | 1 Bit | CRWTU | ||
| 48 | Object 49 | 1 Bit | CRWTU | ||
| 49 | Object 50 | 1 Bit | CRWTU | ||
| 50 | Object 51 | 1 Bit | CRWTU | ||
| 51 | Object 52 | 1 Bit | CRWTU | ||
| 52 | Object 53 | 1 Bit | CRWTU | ||
| 53 | Object 54 | 1 Bit | CRWTU | ||
| 54 | Object 55 | 1 Bit | CRWTU | ||
| 55 | Object 56 | 1 Bit | CRWTU | ||
| 56 | Object 57 | 1 Bit | CRWTU | ||
| 57 | Object 58 | 1 Bit | CRWTU | ||
| 58 | Object 59 | 1 Bit | CRWTU | ||
| 59 | Object 60 | 1 Bit | CRWTU | ||
| 60 | Object 61 | 1 Bit | CRWTU | ||
| 61 | Object 62 | 1 Bit | CRWTU | ||
| 62 | Object 63 | 1 Bit | CRWTU | ||
| 63 | Object 64 | 1 Bit | CRWTU | ||
| 64 | Object 65 | 1 Bit | CRWTU | ||
| 65 | Object 66 | 1 Bit | CRWTU | ||
| 66 | Object 67 | 1 Bit | CRWTU | ||
| 67 | Object 68 | 1 Bit | CRWTU | ||
| 68 | Object 69 | 1 Bit | CRWTU | ||
| 69 | Object 70 | 1 Bit | CRWTU |
Parameters (50)
| Parameter | Type | Default |
|---|---|---|
| Funktion: | list | Master (Standard) |
| Aktive Sensoren | list | Beide |
| Betriebsart: | list | Normalbetrieb |
| Empfindlichkeit: | list | normal (Standard) |
| HLK aktiv: | list | Nein (Standard) |
| Dämmerungsschalter aktiv: | list | Nein (Standard) |
| Meldung aktiv: | list | Nein (Standard) |
| Gehtest während Betrieb aktivierbar: | list | Nein (Standard) |
| Feuchtigkeitsschutz aktivieren | list | Nein (Standard) |
| Zykluszeit Triggerung: | list | 2 min (Standard) |
| Zonenverbund aktiv: | list | Nein (Standard) |
| Subverbund aktiv: | list | Nein (Standard) |
| Helligkeitsverbund aktiv: | list | Nein (Standard) |
| Status Lichtausgang: | list | interner Status (Standard) |
| Helligkeitsschwelle: | list | 200 Lux (Standard) |
| über Bus einstellbar: | list | Nein (Standard) |
| Ausschaltverzögerung: | list | 5 min (Standard) |
| helligkeitsabhängig ausschalten: | list | Nein (Standard) |
| Funktion Lichtausgang: | list | schalten (1 Bit) (Standard) |
| Verhalten bei Beginn Lichtbedarf: | list | EIN Telegramm (Standard) |
| Zykluszeit: | list | 2 min (Standard) |
| Verhalten bei Ende Lichtbedarf: | list | AUS Telegramm (Standard) |
| Szene bei EIN senden: | list | Nein (Standard) |
| Szenennummer bei EIN (1...64): | unsignedInt 1…64 | 1 |
| Szene bei AUS senden: | list | Nein (Standard) |
| Szenennummer bei AUS (1...64): | unsignedInt 1…64 | 1 |
| Licht sperren: | list | Nein (Standard) |
| Verhalten beim Sperren: | list | kein Telegramm (Standard) |
| Verhalten bei Freigabe: | list | kein Telegramm (Standard) |
| Verhalten bei externem Szenenabruf: | list | Still für 4 h (Standard) |
| Verhalten bei externem EIN: | list | EIN und bleiben solange Bewegung (Standard) |
| Zeitdauer: | list | 4 h (Standard) |
| Verhalten bei externem AUS: | list | AUS, nach 5 s wieder EIN falls Bewegung (Öko-Aus) |
| separates, externes Tasterobjekt: | list | Nein (Standard) |
| Einschaltverzögerung: | list | 5 min (Standard) |
| Ausschaltverzögerung: | list | 20 min (Standard) |
| Verhalten bei Beginn HLK-Bedarf: | list | EIN Telegramm (Standard) |
| Verhalten bei Ende HLK-Bedarf: | list | AUS Telegramm (Standard) |
| HLK sperren: | list | Nein (Standard) |
| Dämmerungsschwelle: | list | 150 Lux (Standard) |
| Hysterese: | list | 50 Lux (Standard) |
| Verhalten Dämmerung: | list | dunkel = EIN / hell = AUS |
| Helligkeitswert senden: | list | Nein (Standard) |
| Freigabe der Meldefunktion: | list | Freigabe mit EIN (Aufhebung mit AUS) |
| Empfindlichkeit der Meldefunktion: | list | reduziert (Standard) |
| Anzahl Detektionen für Meldung: | list | 2 (ohne Verbund) (Standard) |
| Verhalten bei Anwesenheit: | list | nur EIN Telegramm senden |
| Nachlaufzeit: | list | 5 min (Standard) |
| Wartezeit auf Quittierung: | list | 5 min (Standard) |
| Lebenszeichen aktiv: | list | Nein (Standard) |
Version history
| Application | App no | Fingerprint | First seen | Size | File |
|---|---|---|---|---|---|
| pirios 180 / basic digi V2.1 2.1 latest | $4418 | C5E2 | 2026-11-25 | 85 KB | Download |
About this file
This is the official ETS product database for the Feller pirios 180 KNX Feuchtigkeitsschutz (44180.KNX.xx), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.
More from Feller
- pirios 360 KNX 44360.KNX.xx
- pirios 360P KNX 44360.P.KNX.xx
- pirios 360P KL KNX 44360.P.x.KL.KNX.xx
- Weather station 4720.MS
- Weather station 8F GPS 4724-8F.MS
- IP-Router REG 36130-00.REG
- KNX/App interface 36140-00.REG
- KNX/app interface V2 36141-00REG
- KNX-DALI-Gateway Plus 36161-00.REG
- DALI-Gateway Tunable White Plus 36162-00.REG
- DALI Gateway Color 1x 36163-01-A.REG
- DALI Gateway Color 2x 36163-02-A.REG