CU-DIN DRY 4-Z KNX EC10430381
ESYLUX · Order number EC10430381 · Module › Kombiniert
Download .knxprod CU-DIN DRY 4-Z KNX 1.0 · 1.7 MB
Product
| Manufacturer | ESYLUX |
|---|---|
| Product name | CU-DIN DRY 4-Z KNX |
| Order number | EC10430381 |
| Hardware | CU-DIN DRY 4-Z KNX |
| Medium | Twisted Pair |
| Rail mounted | No |
| Registration | Registered · 2015-03-17 |
| Languages | de-DE, it-IT, en-US, da-DK, es-ES, fi-FI, fr-FR, nb-NO, nl-NL, pt-PT, ru-RU, sv-SE |
| Catalog entry | M-0080_H-2015.5F03.5F02.5F008-10-O0073_HP-2083-10-9825-O0073_CI-EC10430381-0 |
| Fingerprint | 9825 |
| SHA-256 | efa7072b146387e252238cf28443e680467b0424fd67ec968fb0507354a3318f |
| First seen | 2026-11-25 |
| Markets | 14 markets |
Application program: CU-DIN DRY 4-Z KNX 1.0
| Application number | $2083 |
|---|---|
| Version | 1.0 |
| Mask version | MV-0701 (7.1) |
| KNX Data Secure | No |
| Parameters | 8377 |
| Group objects | 3167 |
Group objects (3167)
| No | Name | Function | Size | DPT | Flags |
|---|---|---|---|---|---|
| 0 | Allgemein | Heartbeat | 1 Bit | 1.3 enable | CT |
| 1 | X | X | 1 Bit | CRWTU | |
| 2 | X | X | 1 Bit | CRWTU | |
| 3 | X | X | 1 Bit | CRWTU | |
| 4 | X | X | 1 Bit | CRWTU | |
| 5 | Allgemein | Sequenz 1 | 1 Bit | 1.10 start/stop | CWU |
| 6 | Allgemein | Sequenz 2 | 1 Bit | 1.10 start/stop | CWU |
| 7 | Allgemein | Sequenz 3 | 1 Bit | 1.10 start/stop | CWU |
| 8 | Allgemein | Sequenz 4 | 1 Bit | 1.10 start/stop | CWU |
| 9 | Allgemein | Sequenz 5 | 1 Bit | 1.10 start/stop | CWU |
| 10 | Eingang A | Sperren | 1 Bit | 1.3 enable | CW |
| 10 | Eingang A | Temperatur | 2 Bytes | 9.1 temperature (°C) | CRT |
| 10 | Logik Block A | Status Eingang EIN/AUS | 1 Bit | 1.2 boolean | CRT |
| 10 | Logik Block A | Temperatur | 2 Bytes | 9.1 temperature (°C) | CRT |
| 10 | Ausgang A | Ausgang | 1 Bit | 1.1 switch | CWU |
| 11 | Eingang A | EIN/AUS | 1 Bit | 1.1 switch | CWTU |
| 11 | Eingang A (kurzer Tastendruck) | EIN/AUS | 1 Bit | 1.1 switch | CWTU |
| 11 | Eingang A (geschlossen) | Schritt auf | 1 Bit | 16.0 Character String (ASCII) | CWTU |
| 11 | Eingang A (geschlossen) | Schritt ab | 1 Bit | 16.0 Character String (ASCII) | CWTU |
| 11 | Eingang A (geschlossen) | Schritt auf/ab abwechselnd | 1 Bit | 16.0 Character String (ASCII) | CWTU |
| 11 | Eingang A (geschlossen) | Auf | 1 Bit | 1.8 up/down | CWTU |
| 11 | Eingang A (geschlossen) | Ab | 1 Bit | 1.8 up/down | CWTU |
| 11 | Eingang A (geschlossen) | Auf/ab abwechselnd | 1 Bit | 1.8 up/down | CWTU |
| 11 | Eingang A (kurzer Tastendruck) | Schritt auf | 1 Bit | 16.0 Character String (ASCII) | CWTU |
| 11 | Eingang A (kurzer Tastendruck) | Schritt ab | 1 Bit | 16.0 Character String (ASCII) | CWTU |
| 11 | Eingang A (kurzer Tastendruck) | Schritt auf/ab abwechselnd | 1 Bit | 16.0 Character String (ASCII) | CWTU |
| 11 | Eingang A (kurzer Tastendruck) | Auf | 1 Bit | 1.8 up/down | CWTU |
| 11 | Eingang A (kurzer Tastendruck) | Ab | 1 Bit | 1.8 up/down | CWTU |
| 11 | Eingang A (kurzer Tastendruck) | Auf/ab abwechselnd | 1 Bit | 1.8 up/down | CWTU |
| 11 | Eingang A | Szene aufrufen | 1 Byte | 16.0 Character String (ASCII) | CWTU |
| 11 | Eingang A (kurzer Tastendruck) | Szene aufrufen | 1 Byte | 16.0 Character String (ASCII) | CWTU |
| 11 | Eingang A | Sequenz | 1 Bit | 1.10 start/stop | CWTU |
| 11 | Eingang A (kurzer Tastendruck) | Sequenz | 1 Bit | 1.10 start/stop | CWTU |
| 11 | Eingang A | 0…100% | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 11 | Eingang A (kurzer Tastendruck) | 0…100% | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 11 | Eingang A (geschlossen) | Wert | 1 Byte | 16.0 Character String (ASCII) | CWTU |
| 11 | Eingang A (geschlossen) | Wert | 2 Bytes | 7.1 pulses | CWTU |
| 11 | Eingang A (kurzer Tastendruck) | Wert | 1 Byte | 16.0 Character String (ASCII) | CWTU |
| 11 | Eingang A (kurzer Tastendruck) | Wert | 2 Bytes | 7.1 pulses | CWTU |
| 11 | Eingang A | String (14 Bytes) | 14 Bytes | 16.0 Character String (ASCII) | CT |
| 11 | Eingang A (kurzer Tastendruck) | String (14 Bytes) | 14 Bytes | 16.0 Character String (ASCII) | CT |
| 11 | Eingang A (geschlossen) | Zwangsführung | 2 Bit | 2.1 switch control | CWTU |
| 11 | Eingang A (geschlossen) | Wert | 2 Bytes | 8.1 pulses difference | CWTU |
| 11 | Eingang A (geschlossen) | Wert | 2 Bytes | 9.1 temperature (°C) | CWTU |
| 11 | Eingang A (geschlossen) | Wert | 4 Bytes | 12.1 counter pulses (unsigned) | CWTU |
| 11 | Eingang A (kurzer Tastendruck) | Zwangsführung | 2 Bit | 2.1 switch control | CWTU |
| 11 | Eingang A (kurzer Tastendruck) | Wert | 2 Bytes | 8.1 pulses difference | CWTU |
| 11 | Eingang A (kurzer Tastendruck) | Wert | 2 Bytes | 9.1 temperature (°C) | CWTU |
| 11 | Eingang A (kurzer Tastendruck) | Wert | 4 Bytes | 12.1 counter pulses (unsigned) | CWTU |
| 11 | Eingang A | Zählerstand | 1 Byte | 5.10 counter pulses (0..255) | CWTU |
| 11 | Eingang A | Zählerstand | 2 Bytes | 7.1 pulses | CWTU |
| 11 | Eingang A | Zählerstand | 4 Bytes | 12.1 counter pulses (unsigned) | CWTU |
| 11 | Eingang A (geschlossen) | EIN/AUS | 1 Bit | 1.1 switch | CT |
| 11 | Eingang A (geschlossen) | Jalousie | 1 Bit | 1.8 up/down | CT |
| 11 | Eingang A (geschlossen) | Szene aufrufen | 1 Byte | 16.0 Character String (ASCII) | CT |
| 11 | Eingang A (geschlossen) | Sequenz Start/Stopp | 1 Bit | 1.10 start/stop | CT |
| 11 | Eingang A (geschlossen) | Wert 0…100% | 1 Byte | 5.1 percentage (0..100%) | CT |
| 11 | Eingang A (geschlossen) | Wert | 1 Byte | 16.0 Character String (ASCII) | CT |
| 11 | Eingang A (geschlossen) | Wert | 2 Bytes | 7.1 pulses | CT |
| 11 | Eingang A (geschlossen) | String (14 Bytes) | 14 Bytes | 16.0 Character String (ASCII) | CT |
| 11 | Eingang A (kurzer Tastendruck) | EIN/AUS | 1 Bit | 1.1 switch | CT |
| 11 | Eingang A (kurzer Tastendruck) | Jalousie | 1 Bit | 1.8 up/down | CT |
| 11 | Eingang A (kurzer Tastendruck) | Szene aufrufen | 1 Byte | 16.0 Character String (ASCII) | CT |
| 11 | Eingang A (kurzer Tastendruck) | Sequenz Start/Stopp | 1 Bit | 1.10 start/stop | CT |
| 11 | Eingang A (kurzer Tastendruck) | Wert 0…100% | 1 Byte | 5.1 percentage (0..100%) | CT |
| 11 | Eingang A (kurzer Tastendruck) | Wert | 1 Byte | 16.0 Character String (ASCII) | CT |
| 11 | Eingang A (kurzer Tastendruck) | Wert | 2 Bytes | 7.1 pulses | CT |
| 11 | Eingang A | Alarm | 1 Bit | 16.0 Character String (ASCII) | CWTU |
| 11 | Eingang A | Auf/Ab | 1 Bit | 1.8 up/down | CWTU |
| 11 | Eingang A (innerhalb/außerhalb Grenzwerte) | Wert | 1 Byte | 16.0 Character String (ASCII) | CWTU |
| 11 | Eingang A (innerhalb/außerhalb Grenzwerte) | Wert | 2 Bytes | 7.1 pulses | CWTU |
| 11 | Eingang A (Grenzwert 1/2) | Wert | 1 Byte | 16.0 Character String (ASCII) | CWTU |
| 11 | Eingang A (Grenzwert 1/2) | Wert | 2 Bytes | 7.1 pulses | CWTU |
| 11 | Eingang A (innerhalb Grenzwerte/an Grenzwert 1) | Zwangsführung | 2 Bit | 2.1 switch control | CWTU |
| 11 | Eingang A (innerhalb Grenzwerte/an Grenzwert 1) | Wert | 1 Byte | 16.0 Character String (ASCII) | CWTU |
| 11 | Eingang A (innerhalb Grenzwerte/an Grenzwert 1) | Wert | 2 Bytes | 8.1 pulses difference | CWTU |
| 11 | Eingang A (innerhalb Grenzwerte/an Grenzwert 1) | Wert | 2 Bytes | 7.1 pulses | CWTU |
| 11 | Eingang A (innerhalb Grenzwerte/an Grenzwert 1) | Wert | 2 Bytes | 9.1 temperature (°C) | CWTU |
| 11 | Eingang A (innerhalb Grenzwerte/an Grenzwert 1) | Wert | 4 Bytes | 12.1 counter pulses (unsigned) | CWTU |
| 11 | Eingang A | Grenzwert 1 | 2 Bytes | 9.1 temperature (°C) | CWU |
| 11 | Logik Block A | Eingang 1 | 1 Bit | 1.1 switch | CWU |
| 11 | Logik Block A | Eingang 1 | 1 Byte | 16.0 Character String (ASCII) | CWU |
| 11 | Logik Block A | Eingang 1 | 2 Bytes | 7.1 pulses | CWU |
| 11 | Logik Block A | Eingang 1 | 2 Bytes | DPT.9 | CWU |
| 11 | Logik Block A | Eingang 1 | 4 Bytes | 12.1 counter pulses (unsigned) | CWU |
| 11 | Ausgang A | Dimmen | 4 Bit | 3.7 dimming control | CWU |
| 12 | Eingang A (langer Tastendruck) | EIN/AUS | 1 Bit | 1.1 switch | CWTU |
| 12 | Eingang A | Dimmen | 4 Bit | 3.7 dimming control | CT |
| 12 | Eingang A (langer Tastendruck) | Dimmen | 4 Bit | 3.7 dimming control | CT |
| 12 | Eingang A (geöffnet) | Schritt auf | 1 Bit | 16.0 Character String (ASCII) | CWTU |
| 12 | Eingang A (geöffnet) | Schritt ab | 1 Bit | 16.0 Character String (ASCII) | CWTU |
| 12 | Eingang A (geöffnet) | Schritt auf/ab abwechselnd | 1 Bit | 16.0 Character String (ASCII) | CWTU |
| 12 | Eingang A (geöffnet) | Auf | 1 Bit | 1.8 up/down | CWTU |
| 12 | Eingang A (geöffnet) | Ab | 1 Bit | 1.8 up/down | CWTU |
| 12 | Eingang A (geöffnet) | Auf/ab abwechselnd | 1 Bit | 1.8 up/down | CWTU |
| 12 | Eingang A (langer Tastendruck) | Schritt auf | 1 Bit | 16.0 Character String (ASCII) | CWTU |
| 12 | Eingang A (langer Tastendruck) | Schritt ab | 1 Bit | 16.0 Character String (ASCII) | CWTU |
| 12 | Eingang A (langer Tastendruck) | Schritt auf/ab abwechselnd | 1 Bit | 16.0 Character String (ASCII) | CWTU |
| 12 | Eingang A (langer Tastendruck) | Auf | 1 Bit | 1.8 up/down | CWTU |
| 12 | Eingang A (langer Tastendruck) | Ab | 1 Bit | 1.8 up/down | CWTU |
| 12 | Eingang A (langer Tastendruck) | Auf/ab abwechselnd | 1 Bit | 1.8 up/down | CWTU |
| 12 | Eingang A (langer Tastendruck) | Sequenz | 1 Bit | 1.10 start/stop | CWTU |
| 12 | Eingang A (langer Tastendruck) | 0…100% | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 12 | Eingang A (geöffnet) | Wert | 1 Byte | 16.0 Character String (ASCII) | CWTU |
| 12 | Eingang A (geöffnet) | Wert | 2 Bytes | 7.1 pulses | CWTU |
| 12 | Eingang A (langer Tastendruck) | Wert | 1 Byte | 16.0 Character String (ASCII) | CWTU |
| 12 | Eingang A (langer Tastendruck) | Wert | 2 Bytes | 7.1 pulses | CWTU |
| 12 | Eingang A (langer Tastendruck) | String (14 Bytes) | 14 Bytes | 16.0 Character String (ASCII) | CT |
| 12 | Eingang A (geöffnet) | Zwangsführung | 2 Bit | 2.1 switch control | CWTU |
| 12 | Eingang A (geöffnet) | Wert | 2 Bytes | 8.1 pulses difference | CWTU |
| 12 | Eingang A (geöffnet) | Wert | 2 Bytes | 9.1 temperature (°C) | CWTU |
| 12 | Eingang A (geöffnet) | Wert | 4 Bytes | 12.1 counter pulses (unsigned) | CWTU |
| 12 | Eingang A (langer Tastendruck) | Zwangsführung | 2 Bit | 2.1 switch control | CWTU |
| 12 | Eingang A (langer Tastendruck) | Wert | 2 Bytes | 8.1 pulses difference | CWTU |
| 12 | Eingang A (langer Tastendruck) | Wert | 2 Bytes | 9.1 temperature (°C) | CWTU |
| 12 | Eingang A (langer Tastendruck) | Wert | 4 Bytes | 12.1 counter pulses (unsigned) | CWTU |
| 12 | Eingang A | Zählerende setzen | 1 Byte | 5.10 counter pulses (0..255) | CWU |
| 12 | Eingang A | Zählerende setzen | 2 Bytes | 7.1 pulses | CWU |
| 12 | Eingang A | Zählerende setzen | 4 Bytes | 12.1 counter pulses (unsigned) | CWU |
| 12 | Eingang A (geschlossen) | EIN/AUS | 1 Bit | 1.1 switch | CT |
| 12 | Eingang A (geschlossen) | Jalousie | 1 Bit | 1.8 up/down | CT |
| 12 | Eingang A (geschlossen) | Szene aufrufen | 1 Byte | 16.0 Character String (ASCII) | CT |
| 12 | Eingang A (geschlossen) | Sequenz Start/Stopp | 1 Bit | 1.10 start/stop | CT |
| 12 | Eingang A (geschlossen) | Wert 0…100% | 1 Byte | 5.1 percentage (0..100%) | CT |
| 12 | Eingang A (geschlossen) | Wert | 1 Byte | 16.0 Character String (ASCII) | CT |
| 12 | Eingang A (geschlossen) | Wert | 2 Bytes | 7.1 pulses | CT |
| 12 | Eingang A (geschlossen) | String (14 Bytes) | 14 Bytes | 16.0 Character String (ASCII) | CT |
| 12 | Eingang A (kurzer Tastendruck) | EIN/AUS | 1 Bit | 1.1 switch | CT |
| 12 | Eingang A (kurzer Tastendruck) | Jalousie | 1 Bit | 1.8 up/down | CT |
| 12 | Eingang A (kurzer Tastendruck) | Szene aufrufen | 1 Byte | 16.0 Character String (ASCII) | CT |
| 12 | Eingang A (kurzer Tastendruck) | Sequenz Start/Stopp | 1 Bit | 1.10 start/stop | CT |
| 12 | Eingang A (kurzer Tastendruck) | Wert 0…100% | 1 Byte | 5.1 percentage (0..100%) | CT |
| 12 | Eingang A (kurzer Tastendruck) | Wert | 1 Byte | 16.0 Character String (ASCII) | CT |
| 12 | Eingang A (kurzer Tastendruck) | Wert | 2 Bytes | 7.1 pulses | CT |
| 12 | Eingang A (kurzer Tastendruck) | String (14 Bytes) | 14 Bytes | 16.0 Character String (ASCII) | CT |
| 12 | Eingang A | Grenzwert 1 | 2 Bytes | 9.1 temperature (°C) | CWU |
| 12 | Eingang A (außerhalb Grenzwerte/an Grenzwert 1) | Zwangsführung | 2 Bit | 2.1 switch control | CWTU |
| 12 | Eingang A (außerhalb Grenzwerte/an Grenzwert 1) | Wert | 1 Byte | 16.0 Character String (ASCII) | CWTU |
| 12 | Eingang A (außerhalb Grenzwerte/an Grenzwert 1) | Wert | 2 Bytes | 8.1 pulses difference | CWTU |
| 12 | Eingang A (außerhalb Grenzwerte/an Grenzwert 1) | Wert | 2 Bytes | 7.1 pulses | CWTU |
| 12 | Eingang A (außerhalb Grenzwerte/an Grenzwert 1) | Wert | 2 Bytes | 9.1 temperature (°C) | CWTU |
| 12 | Eingang A (außerhalb Grenzwerte/an Grenzwert 1) | Wert | 4 Bytes | 12.1 counter pulses (unsigned) | CWTU |
| 12 | Eingang A | Grenzwert 2 | 2 Bytes | 9.1 temperature (°C) | CWU |
| 12 | Logik Block A | Eingang 2 | 1 Bit | 1.1 switch | CWU |
| 12 | Logik Block A | Eingang 2 | 1 Byte | 16.0 Character String (ASCII) | CWU |
| 12 | Logik Block A | Eingang 2 | 2 Bytes | 7.1 pulses | CWU |
| 12 | Logik Block A | Eingang 2 | 2 Bytes | DPT.9 | CWU |
| 12 | Logik Block A | Eingang 2 | 4 Bytes | 12.1 counter pulses (unsigned) | CWU |
| 12 | Ausgang A | Dimmwert | 1 Byte | 5.1 percentage (0..100%) | CWU |
| 13 | Eingang A | Zähler setzen | 1 Byte | 5.10 counter pulses (0..255) | CWU |
| 13 | Eingang A | Zähler setzen | 2 Bytes | 7.1 pulses | CWU |
| 13 | Eingang A | Zähler setzen | 4 Bytes | 12.1 counter pulses (unsigned) | CWU |
| 13 | Eingang A (geschlossen) | EIN/AUS | 1 Bit | 1.1 switch | CT |
| 13 | Eingang A (geschlossen) | Jalousie | 1 Bit | 1.8 up/down | CT |
| 13 | Eingang A (geschlossen) | Szene aufrufen | 1 Byte | 16.0 Character String (ASCII) | CT |
| 13 | Eingang A (geschlossen) | Sequenz Start/Stopp | 1 Bit | 1.10 start/stop | CT |
| 13 | Eingang A (geschlossen) | Wert 0…100% | 1 Byte | 5.1 percentage (0..100%) | CT |
| 13 | Eingang A (geschlossen) | Wert | 1 Byte | 16.0 Character String (ASCII) | CT |
| 13 | Eingang A (geschlossen) | Wert | 2 Bytes | 7.1 pulses | CT |
| 13 | Eingang A (geschlossen) | String (14 Bytes) | 14 Bytes | 16.0 Character String (ASCII) | CT |
| 13 | Eingang A (kurzer Tastendruck) | EIN/AUS | 1 Bit | 1.1 switch | CT |
| 13 | Eingang A (kurzer Tastendruck) | Jalousie | 1 Bit | 1.8 up/down | CT |
| 13 | Eingang A (kurzer Tastendruck) | Szene aufrufen | 1 Byte | 16.0 Character String (ASCII) | CT |
| 13 | Eingang A (kurzer Tastendruck) | Sequenz Start/Stopp | 1 Bit | 1.10 start/stop | CT |
| 13 | Eingang A (kurzer Tastendruck) | Wert 0…100% | 1 Byte | 5.1 percentage (0..100%) | CT |
| 13 | Eingang A (kurzer Tastendruck) | Wert | 1 Byte | 16.0 Character String (ASCII) | CT |
| 13 | Eingang A (kurzer Tastendruck) | Wert | 2 Bytes | 7.1 pulses | CT |
| 13 | Eingang A (kurzer Tastendruck) | String (14 Bytes) | 14 Bytes | 16.0 Character String (ASCII) | CT |
| 13 | Eingang A | Grenzwert 2 | 2 Bytes | 9.1 temperature (°C) | CWU |
| 13 | Eingang A | Grenzwert 1 | 2 Bytes | 9.1 temperature (°C) | CWU |
| 13 | Eingang A (innerhalb Grenzwerte/an Grenzwert 1) | EIN/AUS | 1 Bit | 1.1 switch | CT |
| 13 | Eingang A (innerhalb Grenzwerte/an Grenzwert 1) | Alarm | 1 Bit | 16.0 Character String (ASCII) | CT |
| 13 | Eingang A (innerhalb Grenzwerte/an Grenzwert 1) | Jalousie | 1 Bit | 1.8 up/down | CT |
| 13 | Eingang A (innerhalb Grenzwerte/an Grenzwert 1) | Szene aufrufen | 1 Byte | 16.0 Character String (ASCII) | CT |
| 13 | Eingang A (innerhalb Grenzwerte/an Grenzwert 1) | Sequenz Start/Stopp | 1 Bit | 1.10 start/stop | CT |
| 13 | Eingang A (innerhalb Grenzwerte/an Grenzwert 1) | Wert 0…100% | 1 Byte | 5.1 percentage (0..100%) | CT |
| 13 | Eingang A (innerhalb Grenzwerte/an Grenzwert 1) | Wert | 1 Byte | 16.0 Character String (ASCII) | CT |
| 13 | Eingang A (innerhalb Grenzwerte/an Grenzwert 1) | Wert | 2 Bytes | 7.1 pulses | CT |
| 13 | Eingang A (innerhalb Grenzwerte/an Grenzwert 1) | String (14 Bytes) | 14 Bytes | 16.0 Character String (ASCII) | CT |
| 13 | Logik Block A | Eingang 3 | 1 Bit | 1.1 switch | CWU |
| 13 | Logik Block A | Eingang 3 | 1 Byte | 16.0 Character String (ASCII) | CWU |
| 13 | Logik Block A | Eingang 3 | 2 Bytes | 7.1 pulses | CWU |
| 13 | Logik Block A | Eingang 3 | 2 Bytes | DPT.9 | CWU |
| 13 | Logik Block A | Eingang 3 | 4 Bytes | 12.1 counter pulses (unsigned) | CWU |
| 13 | Ausgang A | Status EIN/AUS | 1 Bit | 1.1 switch | CRT |
| 14 | Eingang A | Alarm Zähler | 1 Bit | 16.0 Character String (ASCII) | CT |
| 14 | Eingang A (geschlossen) | EIN/AUS | 1 Bit | 1.1 switch | CT |
| 14 | Eingang A (geschlossen) | Jalousie | 1 Bit | 1.8 up/down | CT |
| 14 | Eingang A (geschlossen) | Szene aufrufen | 1 Byte | 16.0 Character String (ASCII) | CT |
| 14 | Eingang A (geschlossen) | Sequenz Start/Stopp | 1 Bit | 1.10 start/stop | CT |
| 14 | Eingang A (geschlossen) | Wert 0…100% | 1 Byte | 5.1 percentage (0..100%) | CT |
| 14 | Eingang A (geschlossen) | Wert | 1 Byte | 16.0 Character String (ASCII) | CT |
| 14 | Eingang A (geschlossen) | Wert | 2 Bytes | 7.1 pulses | CT |
| 14 | Eingang A (geschlossen) | String (14 Bytes) | 14 Bytes | 16.0 Character String (ASCII) | CT |
| 14 | Eingang A (kurzer Tastendruck) | EIN/AUS | 1 Bit | 1.1 switch | CT |
| 14 | Eingang A (kurzer Tastendruck) | Jalousie | 1 Bit | 1.8 up/down | CT |
| 14 | Eingang A (kurzer Tastendruck) | Szene aufrufen | 1 Byte | 16.0 Character String (ASCII) | CT |
| 14 | Eingang A (kurzer Tastendruck) | Sequenz Start/Stopp | 1 Bit | 1.10 start/stop | CT |
| 14 | Eingang A (kurzer Tastendruck) | Wert 0…100% | 1 Byte | 5.1 percentage (0..100%) | CT |
| 14 | Eingang A (kurzer Tastendruck) | Wert | 1 Byte | 16.0 Character String (ASCII) | CT |
| 14 | Eingang A (kurzer Tastendruck) | Wert | 2 Bytes | 7.1 pulses | CT |
| 14 | Eingang A (kurzer Tastendruck) | String (14 Bytes) | 14 Bytes | 16.0 Character String (ASCII) | CT |
| 14 | Eingang A | Zwangsführung | 1 Bit | 1.1 switch | CWU |
| 14 | Eingang A | Alarm | 1 Bit | 1.1 switch | CWU |
| 14 | Eingang A | Auf/Ab | 1 Bit | 1.1 switch | CWU |
| 14 | Eingang A | Szene aufrufen | 1 Bit | 1.1 switch | CWU |
| 14 | Eingang A | Sequenz | 1 Bit | 1.1 switch | CWU |
| 14 | Eingang A | Wert (0…100%) | 1 Bit | 1.1 switch | CWU |
| 14 | Eingang A | Wert | 1 Bit | 1.1 switch | CWU |
| 14 | Eingang A | String (14 Bytes) | 1 Bit | 1.1 switch | CWU |
| 14 | Eingang A | Grenzwert 2 | 2 Bytes | 9.1 temperature (°C) | CWU |
| 14 | Eingang A (innerhalb Grenzwerte/an Grenzwert 1) | EIN/AUS | 1 Bit | 1.1 switch | CT |
| 14 | Eingang A (innerhalb Grenzwerte/an Grenzwert 1) | Alarm | 1 Bit | 16.0 Character String (ASCII) | CT |
| 14 | Eingang A (innerhalb Grenzwerte/an Grenzwert 1) | Jalousie | 1 Bit | 1.8 up/down | CT |
| 14 | Eingang A (innerhalb Grenzwerte/an Grenzwert 1) | Szene aufrufen | 1 Byte | 16.0 Character String (ASCII) | CT |
| 14 | Eingang A (innerhalb Grenzwerte/an Grenzwert 1) | Sequenz Start/Stopp | 1 Bit | 1.10 start/stop | CT |
| 14 | Eingang A (innerhalb Grenzwerte/an Grenzwert 1) | Wert 0…100% | 1 Byte | 5.1 percentage (0..100%) | CT |
| 14 | Eingang A (innerhalb Grenzwerte/an Grenzwert 1) | Wert | 1 Byte | 16.0 Character String (ASCII) | CT |
| 14 | Eingang A (innerhalb Grenzwerte/an Grenzwert 1) | Wert | 2 Bytes | 7.1 pulses | CT |
| 14 | Eingang A (innerhalb Grenzwerte/an Grenzwert 1) | String (14 Bytes) | 14 Bytes | 16.0 Character String (ASCII) | CT |
| 14 | Logik Block A | Eingang 4 | 1 Bit | 1.1 switch | CWU |
| 14 | Logik Block A | Eingang 4 | 1 Byte | 16.0 Character String (ASCII) | CWU |
| 14 | Logik Block A | Eingang 4 | 2 Bytes | 7.1 pulses | CWU |
| 14 | Logik Block A | Eingang 4 | 2 Bytes | DPT.9 | CWU |
| 14 | Logik Block A | Eingang 4 | 4 Bytes | 12.1 counter pulses (unsigned) | CWU |
| 14 | Ausgang A | Status 0…100% | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 15 | Eingang A (geschlossen) | EIN/AUS | 1 Bit | 1.1 switch | CT |
| 15 | Eingang A (geschlossen) | Jalousie | 1 Bit | 1.8 up/down | CT |
| 15 | Eingang A (geschlossen) | Szene aufrufen | 1 Byte | 16.0 Character String (ASCII) | CT |
| 15 | Eingang A (geschlossen) | Sequenz Start/Stopp | 1 Bit | 1.10 start/stop | CT |
| 15 | Eingang A (geschlossen) | Wert 0…100% | 1 Byte | 5.1 percentage (0..100%) | CT |
| 15 | Eingang A (geschlossen) | Wert | 1 Byte | 16.0 Character String (ASCII) | CT |
| 15 | Eingang A (geschlossen) | Wert | 2 Bytes | 7.1 pulses | CT |
| 15 | Eingang A (geschlossen) | String (14 Bytes) | 14 Bytes | 16.0 Character String (ASCII) | CT |
| 15 | Eingang A (kurzer Tastendruck) | EIN/AUS | 1 Bit | 1.1 switch | CT |
| 15 | Eingang A (kurzer Tastendruck) | Jalousie | 1 Bit | 1.8 up/down | CT |
| 15 | Eingang A (kurzer Tastendruck) | Szene aufrufen | 1 Byte | 16.0 Character String (ASCII) | CT |
| 15 | Eingang A (kurzer Tastendruck) | Sequenz Start/Stopp | 1 Bit | 1.10 start/stop | CT |
| 15 | Eingang A (kurzer Tastendruck) | Wert 0…100% | 1 Byte | 5.1 percentage (0..100%) | CT |
| 15 | Eingang A (kurzer Tastendruck) | Wert | 1 Byte | 16.0 Character String (ASCII) | CT |
| 15 | Eingang A (kurzer Tastendruck) | Wert | 2 Bytes | 7.1 pulses | CT |
| 15 | Eingang A (kurzer Tastendruck) | String (14 Bytes) | 14 Bytes | 16.0 Character String (ASCII) | CT |
| 15 | Eingang A (innerhalb Grenzwerte/an Grenzwert 1) | EIN/AUS | 1 Bit | 1.1 switch | CT |
| 15 | Eingang A (innerhalb Grenzwerte/an Grenzwert 1) | Alarm | 1 Bit | 16.0 Character String (ASCII) | CT |
| 15 | Eingang A (innerhalb Grenzwerte/an Grenzwert 1) | Jalousie | 1 Bit | 1.8 up/down | CT |
| 15 | Eingang A (innerhalb Grenzwerte/an Grenzwert 1) | Szene aufrufen | 1 Byte | 16.0 Character String (ASCII) | CT |
| 15 | Eingang A (innerhalb Grenzwerte/an Grenzwert 1) | Sequenz Start/Stopp | 1 Bit | 1.10 start/stop | CT |
| 15 | Eingang A (innerhalb Grenzwerte/an Grenzwert 1) | Wert 0…100% | 1 Byte | 5.1 percentage (0..100%) | CT |
| 15 | Eingang A (innerhalb Grenzwerte/an Grenzwert 1) | Wert | 1 Byte | 16.0 Character String (ASCII) | CT |
| 15 | Eingang A (innerhalb Grenzwerte/an Grenzwert 1) | Wert | 2 Bytes | 7.1 pulses | CT |
| 15 | Eingang A (innerhalb Grenzwerte/an Grenzwert 1) | String (14 Bytes) | 14 Bytes | 16.0 Character String (ASCII) | CT |
| 15 | Logik Block A | Eingang 5 | 1 Bit | 1.1 switch | CWU |
| 15 | Logik Block A | Eingang 5 | 1 Byte | 16.0 Character String (ASCII) | CWU |
| 15 | Logik Block A | Eingang 5 | 2 Bytes | 7.1 pulses | CWU |
| 15 | Logik Block A | Eingang 5 | 2 Bytes | DPT.9 | CWU |
| 15 | Logik Block A | Eingang 5 | 4 Bytes | 12.1 counter pulses (unsigned) | CWU |
| 15 | Ausgang A | Relaissynchronisation | 1 Bit | 1.1 switch | CT |
| 16 | Eingang A (geschlossen) | EIN/AUS | 1 Bit | 1.1 switch | CT |
| 16 | Eingang A (geschlossen) | Jalousie | 1 Bit | 1.8 up/down | CT |
| 16 | Eingang A (geschlossen) | Szene aufrufen | 1 Byte | 16.0 Character String (ASCII) | CT |
| 16 | Eingang A (geschlossen) | Sequenz Start/Stopp | 1 Bit | 1.10 start/stop | CT |
| 16 | Eingang A (geschlossen) | Wert 0…100% | 1 Byte | 5.1 percentage (0..100%) | CT |
| 16 | Eingang A (geschlossen) | Wert | 1 Byte | 16.0 Character String (ASCII) | CT |
| 16 | Eingang A (geschlossen) | Wert | 2 Bytes | 7.1 pulses | CT |
| 16 | Eingang A (geschlossen) | String (14 Bytes) | 14 Bytes | 16.0 Character String (ASCII) | CT |
| 16 | Eingang A (kurzer Tastendruck) | EIN/AUS | 1 Bit | 1.1 switch | CT |
| 16 | Eingang A (kurzer Tastendruck) | Jalousie | 1 Bit | 1.8 up/down | CT |
| 16 | Eingang A (kurzer Tastendruck) | Szene aufrufen | 1 Byte | 16.0 Character String (ASCII) | CT |
| 16 | Eingang A (kurzer Tastendruck) | Sequenz Start/Stopp | 1 Bit | 1.10 start/stop | CT |
| 16 | Eingang A (kurzer Tastendruck) | Wert 0…100% | 1 Byte | 5.1 percentage (0..100%) | CT |
| 16 | Eingang A (kurzer Tastendruck) | Wert | 1 Byte | 16.0 Character String (ASCII) | CT |
| 16 | Eingang A (kurzer Tastendruck) | Wert | 2 Bytes | 7.1 pulses | CT |
| 16 | Eingang A (kurzer Tastendruck) | String (14 Bytes) | 14 Bytes | 16.0 Character String (ASCII) | CT |
| 16 | Eingang A (innerhalb Grenzwerte/an Grenzwert 1) | EIN/AUS | 1 Bit | 1.1 switch | CT |
| 16 | Eingang A (innerhalb Grenzwerte/an Grenzwert 1) | Alarm | 1 Bit | 16.0 Character String (ASCII) | CT |
| 16 | Eingang A (innerhalb Grenzwerte/an Grenzwert 1) | Jalousie | 1 Bit | 1.8 up/down | CT |
| 16 | Eingang A (innerhalb Grenzwerte/an Grenzwert 1) | Szene aufrufen | 1 Byte | 16.0 Character String (ASCII) | CT |
| 16 | Eingang A (innerhalb Grenzwerte/an Grenzwert 1) | Sequenz Start/Stopp | 1 Bit | 1.10 start/stop | CT |
| 16 | Eingang A (innerhalb Grenzwerte/an Grenzwert 1) | Wert 0…100% | 1 Byte | 5.1 percentage (0..100%) | CT |
| 16 | Eingang A (innerhalb Grenzwerte/an Grenzwert 1) | Wert | 1 Byte | 16.0 Character String (ASCII) | CT |
| 16 | Eingang A (innerhalb Grenzwerte/an Grenzwert 1) | Wert | 2 Bytes | 7.1 pulses | CT |
| 16 | Eingang A (innerhalb Grenzwerte/an Grenzwert 1) | String (14 Bytes) | 14 Bytes | 16.0 Character String (ASCII) | CT |
| 16 | Logik Block A Ausgang 1 | EIN/AUS | 1 Bit | 1.1 switch | CWTU |
| 16 | Logik Block A Ausgang 1 | Alarm | 1 Bit | 16.0 Character String (ASCII) | CWTU |
| 16 | Logik Block A Ausgang 1 | Jalousie | 1 Bit | 1.8 up/down | CWTU |
| 16 | Logik Block A Ausgang 1 | Szene aufrufen | 1 Byte | 16.0 Character String (ASCII) | CWTU |
| 16 | Logik Block A Ausgang 1 | Sequenz | 1 Bit | 1.10 start/stop | CWTU |
| 16 | Logik Block A Ausgang 1 | Wert (0…100%) | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 16 | Logik Block A Ausgang 1 | Wert | 1 Byte | 16.0 Character String (ASCII) | CWTU |
| 16 | Logik Block A Ausgang 1 | Wert | 2 Bytes | 7.1 pulses | CWTU |
| 16 | Logik Block A Ausgang 1 | String (14 Bytes) | 14 Bytes | 16.0 Character String (ASCII) | CT |
| 16 | Ausgang A | Temperatur | 2 Bytes | 9.1 temperature (°C) | CRT |
| 17 | Eingang A (geschlossen) | EIN/AUS | 1 Bit | 1.1 switch | CT |
| 17 | Eingang A (geschlossen) | Jalousie | 1 Bit | 1.8 up/down | CT |
| 17 | Eingang A (geschlossen) | Szene aufrufen | 1 Byte | 16.0 Character String (ASCII) | CT |
| 17 | Eingang A (geschlossen) | Sequenz Start/Stopp | 1 Bit | 1.10 start/stop | CT |
| 17 | Eingang A (geschlossen) | Wert 0…100% | 1 Byte | 5.1 percentage (0..100%) | CT |
| 17 | Eingang A (geschlossen) | Wert | 1 Byte | 16.0 Character String (ASCII) | CT |
| 17 | Eingang A (geschlossen) | Wert | 2 Bytes | 7.1 pulses | CT |
| 17 | Eingang A (geschlossen) | String (14 Bytes) | 14 Bytes | 16.0 Character String (ASCII) | CT |
| 17 | Eingang A (kurzer Tastendruck) | EIN/AUS | 1 Bit | 1.1 switch | CT |
| 17 | Eingang A (kurzer Tastendruck) | Jalousie | 1 Bit | 1.8 up/down | CT |
| 17 | Eingang A (kurzer Tastendruck) | Szene aufrufen | 1 Byte | 16.0 Character String (ASCII) | CT |
| 17 | Eingang A (kurzer Tastendruck) | Sequenz Start/Stopp | 1 Bit | 1.10 start/stop | CT |
| 17 | Eingang A (kurzer Tastendruck) | Wert 0…100% | 1 Byte | 5.1 percentage (0..100%) | CT |
| 17 | Eingang A (kurzer Tastendruck) | Wert | 1 Byte | 16.0 Character String (ASCII) | CT |
| 17 | Eingang A (kurzer Tastendruck) | Wert | 2 Bytes | 7.1 pulses | CT |
| 17 | Eingang A (kurzer Tastendruck) | String (14 Bytes) | 14 Bytes | 16.0 Character String (ASCII) | CT |
| 17 | Eingang A (innerhalb Grenzwerte/an Grenzwert 1) | EIN/AUS | 1 Bit | 1.1 switch | CT |
| 17 | Eingang A (innerhalb Grenzwerte/an Grenzwert 1) | Alarm | 1 Bit | 16.0 Character String (ASCII) | CT |
| 17 | Eingang A (innerhalb Grenzwerte/an Grenzwert 1) | Jalousie | 1 Bit | 1.8 up/down | CT |
| 17 | Eingang A (innerhalb Grenzwerte/an Grenzwert 1) | Szene aufrufen | 1 Byte | 16.0 Character String (ASCII) | CT |
| 17 | Eingang A (innerhalb Grenzwerte/an Grenzwert 1) | Sequenz Start/Stopp | 1 Bit | 1.10 start/stop | CT |
| 17 | Eingang A (innerhalb Grenzwerte/an Grenzwert 1) | Wert 0…100% | 1 Byte | 5.1 percentage (0..100%) | CT |
| 17 | Eingang A (innerhalb Grenzwerte/an Grenzwert 1) | Wert | 1 Byte | 16.0 Character String (ASCII) | CT |
| 17 | Eingang A (innerhalb Grenzwerte/an Grenzwert 1) | Wert | 2 Bytes | 7.1 pulses | CT |
| 17 | Eingang A (innerhalb Grenzwerte/an Grenzwert 1) | String (14 Bytes) | 14 Bytes | 16.0 Character String (ASCII) | CT |
| 17 | Logik Block A Ausgang 2 | EIN/AUS | 1 Bit | 1.1 switch | CWTU |
| 17 | Logik Block A Ausgang 2 | Alarm | 1 Bit | 16.0 Character String (ASCII) | CWTU |
| 17 | Logik Block A Ausgang 2 | Jalousie | 1 Bit | 1.8 up/down | CWTU |
| 17 | Logik Block A Ausgang 2 | Szene aufrufen | 1 Byte | 16.0 Character String (ASCII) | CWTU |
| 17 | Logik Block A Ausgang 2 | Sequenz | 1 Bit | 1.10 start/stop | CWTU |
| 17 | Logik Block A Ausgang 2 | Wert (0…100%) | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 17 | Logik Block A Ausgang 2 | Wert | 1 Byte | 16.0 Character String (ASCII) | CWTU |
| 17 | Logik Block A Ausgang 2 | Wert | 2 Bytes | 7.1 pulses | CWTU |
| 17 | Logik Block A Ausgang 2 | String (14 Bytes) | 14 Bytes | 16.0 Character String (ASCII) | CT |
| 17 | Ausgang A | Betriebsstunden | 2 Bytes | 16.0 Character String (ASCII) | CRWTU |
| 18 | Eingang A (geschlossen) | EIN/AUS | 1 Bit | 1.1 switch | CT |
| 18 | Eingang A (geschlossen) | Jalousie | 1 Bit | 1.8 up/down | CT |
| 18 | Eingang A (geschlossen) | Szene aufrufen | 1 Byte | 16.0 Character String (ASCII) | CT |
| 18 | Eingang A (geschlossen) | Sequenz Start/Stopp | 1 Bit | 1.10 start/stop | CT |
| 18 | Eingang A (geschlossen) | Wert 0…100% | 1 Byte | 5.1 percentage (0..100%) | CT |
| 18 | Eingang A (geschlossen) | Wert | 1 Byte | 16.0 Character String (ASCII) | CT |
| 18 | Eingang A (geschlossen) | Wert | 2 Bytes | 7.1 pulses | CT |
| 18 | Eingang A (geschlossen) | String (14 Bytes) | 14 Bytes | 16.0 Character String (ASCII) | CT |
| 18 | Eingang A (kurzer Tastendruck) | EIN/AUS | 1 Bit | 1.1 switch | CT |
| 18 | Eingang A (kurzer Tastendruck) | Jalousie | 1 Bit | 1.8 up/down | CT |
| 18 | Eingang A (kurzer Tastendruck) | Szene aufrufen | 1 Byte | 16.0 Character String (ASCII) | CT |
| 18 | Eingang A (kurzer Tastendruck) | Sequenz Start/Stopp | 1 Bit | 1.10 start/stop | CT |
| 18 | Eingang A (kurzer Tastendruck) | Wert 0…100% | 1 Byte | 5.1 percentage (0..100%) | CT |
| 18 | Eingang A (kurzer Tastendruck) | Wert | 1 Byte | 16.0 Character String (ASCII) | CT |
| 18 | Eingang A (kurzer Tastendruck) | Wert | 2 Bytes | 7.1 pulses | CT |
| 18 | Eingang A (kurzer Tastendruck) | String (14 Bytes) | 14 Bytes | 16.0 Character String (ASCII) | CT |
| 18 | Eingang A (innerhalb Grenzwerte/an Grenzwert 1) | EIN/AUS | 1 Bit | 1.1 switch | CT |
| 18 | Eingang A (innerhalb Grenzwerte/an Grenzwert 1) | Alarm | 1 Bit | 16.0 Character String (ASCII) | CT |
| 18 | Eingang A (innerhalb Grenzwerte/an Grenzwert 1) | Jalousie | 1 Bit | 1.8 up/down | CT |
| 18 | Eingang A (innerhalb Grenzwerte/an Grenzwert 1) | Szene aufrufen | 1 Byte | 16.0 Character String (ASCII) | CT |
| 18 | Eingang A (innerhalb Grenzwerte/an Grenzwert 1) | Sequenz Start/Stopp | 1 Bit | 1.10 start/stop | CT |
| 18 | Eingang A (innerhalb Grenzwerte/an Grenzwert 1) | Wert 0…100% | 1 Byte | 5.1 percentage (0..100%) | CT |
| 18 | Eingang A (innerhalb Grenzwerte/an Grenzwert 1) | Wert | 1 Byte | 16.0 Character String (ASCII) | CT |
| 18 | Eingang A (innerhalb Grenzwerte/an Grenzwert 1) | Wert | 2 Bytes | 7.1 pulses | CT |
| 18 | Eingang A (innerhalb Grenzwerte/an Grenzwert 1) | String (14 Bytes) | 14 Bytes | 16.0 Character String (ASCII) | CT |
| 18 | Logik Block A Ausgang 3 | EIN/AUS | 1 Bit | 1.1 switch | CWTU |
| 18 | Logik Block A Ausgang 3 | Alarm | 1 Bit | 16.0 Character String (ASCII) | CWTU |
| 18 | Logik Block A Ausgang 3 | Jalousie | 1 Bit | 1.8 up/down | CWTU |
| 18 | Logik Block A Ausgang 3 | Szene aufrufen | 1 Byte | 16.0 Character String (ASCII) | CWTU |
| 18 | Logik Block A Ausgang 3 | Sequenz | 1 Bit | 1.10 start/stop | CWTU |
| 18 | Logik Block A Ausgang 3 | Wert (0…100%) | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 18 | Logik Block A Ausgang 3 | Wert | 1 Byte | 16.0 Character String (ASCII) | CWTU |
| 18 | Logik Block A Ausgang 3 | Wert | 2 Bytes | 7.1 pulses | CWTU |
| 18 | Logik Block A Ausgang 3 | String (14 Bytes) | 14 Bytes | 16.0 Character String (ASCII) | CT |
| 18 | Ausgang A | Alarm Betriebsstunden | 1 Bit | 16.0 Character String (ASCII) | CRT |
| 19 | Eingang A (geschlossen) | EIN/AUS | 1 Bit | 1.1 switch | CT |
| 19 | Eingang A (geschlossen) | Jalousie | 1 Bit | 1.8 up/down | CT |
| 19 | Eingang A (geschlossen) | Szene aufrufen | 1 Byte | 16.0 Character String (ASCII) | CT |
| 19 | Eingang A (geschlossen) | Sequenz Start/Stopp | 1 Bit | 1.10 start/stop | CT |
| 19 | Eingang A (geschlossen) | Wert 0…100% | 1 Byte | 5.1 percentage (0..100%) | CT |
| 19 | Eingang A (geschlossen) | Wert | 1 Byte | 16.0 Character String (ASCII) | CT |
| 19 | Eingang A (geschlossen) | Wert | 2 Bytes | 7.1 pulses | CT |
| 19 | Eingang A (geschlossen) | String (14 Bytes) | 14 Bytes | 16.0 Character String (ASCII) | CT |
| 19 | Eingang A (kurzer Tastendruck) | EIN/AUS | 1 Bit | 1.1 switch | CT |
| 19 | Eingang A (kurzer Tastendruck) | Jalousie | 1 Bit | 1.8 up/down | CT |
| 19 | Eingang A (kurzer Tastendruck) | Szene aufrufen | 1 Byte | 16.0 Character String (ASCII) | CT |
| 19 | Eingang A (kurzer Tastendruck) | Sequenz Start/Stopp | 1 Bit | 1.10 start/stop | CT |
| 19 | Eingang A (kurzer Tastendruck) | Wert 0…100% | 1 Byte | 5.1 percentage (0..100%) | CT |
| 19 | Eingang A (kurzer Tastendruck) | Wert | 1 Byte | 16.0 Character String (ASCII) | CT |
| 19 | Eingang A (kurzer Tastendruck) | Wert | 2 Bytes | 7.1 pulses | CT |
| 19 | Eingang A (kurzer Tastendruck) | String (14 Bytes) | 14 Bytes | 16.0 Character String (ASCII) | CT |
| 19 | Eingang A (innerhalb Grenzwerte/an Grenzwert 1) | EIN/AUS | 1 Bit | 1.1 switch | CT |
| 19 | Eingang A (innerhalb Grenzwerte/an Grenzwert 1) | Alarm | 1 Bit | 16.0 Character String (ASCII) | CT |
| 19 | Eingang A (innerhalb Grenzwerte/an Grenzwert 1) | Jalousie | 1 Bit | 1.8 up/down | CT |
| 19 | Eingang A (innerhalb Grenzwerte/an Grenzwert 1) | Szene aufrufen | 1 Byte | 16.0 Character String (ASCII) | CT |
| 19 | Eingang A (innerhalb Grenzwerte/an Grenzwert 1) | Sequenz Start/Stopp | 1 Bit | 1.10 start/stop | CT |
| 19 | Eingang A (innerhalb Grenzwerte/an Grenzwert 1) | Wert 0…100% | 1 Byte | 5.1 percentage (0..100%) | CT |
| 19 | Eingang A (innerhalb Grenzwerte/an Grenzwert 1) | Wert | 1 Byte | 16.0 Character String (ASCII) | CT |
| 19 | Eingang A (innerhalb Grenzwerte/an Grenzwert 1) | Wert | 2 Bytes | 7.1 pulses | CT |
| 19 | Eingang A (innerhalb Grenzwerte/an Grenzwert 1) | String (14 Bytes) | 14 Bytes | 16.0 Character String (ASCII) | CT |
| 19 | Logik Block A Ausgang 4 | EIN/AUS | 1 Bit | 1.1 switch | CWTU |
| 19 | Logik Block A Ausgang 4 | Alarm | 1 Bit | 16.0 Character String (ASCII) | CWTU |
| 19 | Logik Block A Ausgang 4 | Jalousie | 1 Bit | 1.8 up/down | CWTU |
| 19 | Logik Block A Ausgang 4 | Szene aufrufen | 1 Byte | 16.0 Character String (ASCII) | CWTU |
| 19 | Logik Block A Ausgang 4 | Sequenz | 1 Bit | 1.10 start/stop | CWTU |
| 19 | Logik Block A Ausgang 4 | Wert (0…100%) | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 19 | Logik Block A Ausgang 4 | Wert | 1 Byte | 16.0 Character String (ASCII) | CWTU |
| 19 | Logik Block A Ausgang 4 | Wert | 2 Bytes | 7.1 pulses | CWTU |
| 19 | Logik Block A Ausgang 4 | String (14 Bytes) | 14 Bytes | 16.0 Character String (ASCII) | CT |
| 19 | Ausgang A | Treppenhauslicht EIN/AUS | 1 Bit | 1.1 switch | CWU |
| 20 | Eingang A (geschlossen) | EIN/AUS | 1 Bit | 1.1 switch | CT |
| 20 | Eingang A (geschlossen) | Jalousie | 1 Bit | 1.8 up/down | CT |
| 20 | Eingang A (geschlossen) | Szene aufrufen | 1 Byte | 16.0 Character String (ASCII) | CT |
| 20 | Eingang A (geschlossen) | Sequenz Start/Stopp | 1 Bit | 1.10 start/stop | CT |
| 20 | Eingang A (geschlossen) | Wert 0…100% | 1 Byte | 5.1 percentage (0..100%) | CT |
| 20 | Eingang A (geschlossen) | Wert | 1 Byte | 16.0 Character String (ASCII) | CT |
| 20 | Eingang A (geschlossen) | Wert | 2 Bytes | 7.1 pulses | CT |
| 20 | Eingang A (geschlossen) | String (14 Bytes) | 14 Bytes | 16.0 Character String (ASCII) | CT |
| 20 | Eingang A (kurzer Tastendruck) | EIN/AUS | 1 Bit | 1.1 switch | CT |
| 20 | Eingang A (kurzer Tastendruck) | Jalousie | 1 Bit | 1.8 up/down | CT |
| 20 | Eingang A (kurzer Tastendruck) | Szene aufrufen | 1 Byte | 16.0 Character String (ASCII) | CT |
| 20 | Eingang A (kurzer Tastendruck) | Sequenz Start/Stopp | 1 Bit | 1.10 start/stop | CT |
| 20 | Eingang A (kurzer Tastendruck) | Wert 0…100% | 1 Byte | 5.1 percentage (0..100%) | CT |
| 20 | Eingang A (kurzer Tastendruck) | Wert | 1 Byte | 16.0 Character String (ASCII) | CT |
| 20 | Eingang A (kurzer Tastendruck) | Wert | 2 Bytes | 7.1 pulses | CT |
| 20 | Eingang A (kurzer Tastendruck) | String (14 Bytes) | 14 Bytes | 16.0 Character String (ASCII) | CT |
| 20 | Eingang A (innerhalb Grenzwerte/an Grenzwert 1) | EIN/AUS | 1 Bit | 1.1 switch | CT |
| 20 | Eingang A (innerhalb Grenzwerte/an Grenzwert 1) | Alarm | 1 Bit | 16.0 Character String (ASCII) | CT |
| 20 | Eingang A (innerhalb Grenzwerte/an Grenzwert 1) | Jalousie | 1 Bit | 1.8 up/down | CT |
| 20 | Eingang A (innerhalb Grenzwerte/an Grenzwert 1) | Szene aufrufen | 1 Byte | 16.0 Character String (ASCII) | CT |
| 20 | Eingang A (innerhalb Grenzwerte/an Grenzwert 1) | Sequenz Start/Stopp | 1 Bit | 1.10 start/stop | CT |
| 20 | Eingang A (innerhalb Grenzwerte/an Grenzwert 1) | Wert 0…100% | 1 Byte | 5.1 percentage (0..100%) | CT |
| 20 | Eingang A (innerhalb Grenzwerte/an Grenzwert 1) | Wert | 1 Byte | 16.0 Character String (ASCII) | CT |
| 20 | Eingang A (innerhalb Grenzwerte/an Grenzwert 1) | Wert | 2 Bytes | 7.1 pulses | CT |
| 20 | Eingang A (innerhalb Grenzwerte/an Grenzwert 1) | String (14 Bytes) | 14 Bytes | 16.0 Character String (ASCII) | CT |
| 20 | Logik Block A Ausgang 5 | EIN/AUS | 1 Bit | 1.1 switch | CWTU |
| 20 | Logik Block A Ausgang 5 | Alarm | 1 Bit | 16.0 Character String (ASCII) | CWTU |
| 20 | Logik Block A Ausgang 5 | Jalousie | 1 Bit | 1.8 up/down | CWTU |
| 20 | Logik Block A Ausgang 5 | Szene aufrufen | 1 Byte | 16.0 Character String (ASCII) | CWTU |
| 20 | Logik Block A Ausgang 5 | Sequenz | 1 Bit | 1.10 start/stop | CWTU |
| 20 | Logik Block A Ausgang 5 | Wert (0…100%) | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 20 | Logik Block A Ausgang 5 | Wert | 1 Byte | 16.0 Character String (ASCII) | CWTU |
| 20 | Logik Block A Ausgang 5 | Wert | 2 Bytes | 7.1 pulses | CWTU |
| 20 | Logik Block A Ausgang 5 | String (14 Bytes) | 14 Bytes | 16.0 Character String (ASCII) | CT |
| 20 | Ausgang A | Dauer Treppenhauslicht | 1 Byte | 16.0 Character String (ASCII) | CWU |
| 21 | Eingang A (geöffnet) | EIN/AUS | 1 Bit | 1.1 switch | CT |
| 21 | Eingang A (geöffnet) | Jalousie | 1 Bit | 1.8 up/down | CT |
| 21 | Eingang A (geöffnet) | Szene aufrufen | 1 Byte | 16.0 Character String (ASCII) | CT |
| 21 | Eingang A (geöffnet) | Sequenz Start/Stopp | 1 Bit | 1.10 start/stop | CT |
| 21 | Eingang A (geöffnet) | Wert 0…100% | 1 Byte | 5.1 percentage (0..100%) | CT |
| 21 | Eingang A (geöffnet) | Wert | 1 Byte | 16.0 Character String (ASCII) | CT |
| 21 | Eingang A (geöffnet) | Wert | 2 Bytes | 7.1 pulses | CT |
| 21 | Eingang A (geöffnet) | String (14 Bytes) | 14 Bytes | 16.0 Character String (ASCII) | CT |
| 21 | Eingang A (langer Tastendruck) | EIN/AUS | 1 Bit | 1.1 switch | CT |
| 21 | Eingang A (langer Tastendruck) | Jalousie | 1 Bit | 1.8 up/down | CT |
| 21 | Eingang A (langer Tastendruck) | Szene aufrufen | 1 Byte | 16.0 Character String (ASCII) | CT |
| 21 | Eingang A (langer Tastendruck) | Sequenz Start/Stopp | 1 Bit | 1.10 start/stop | CT |
| 21 | Eingang A (langer Tastendruck) | Wert 0…100% | 1 Byte | 5.1 percentage (0..100%) | CT |
| 21 | Eingang A (langer Tastendruck) | Wert | 1 Byte | 16.0 Character String (ASCII) | CT |
| 21 | Eingang A (langer Tastendruck) | Wert | 2 Bytes | 7.1 pulses | CT |
| 21 | Eingang A (langer Tastendruck) | String (14 Bytes) | 14 Bytes | 16.0 Character String (ASCII) | CT |
| 21 | Eingang A (innerhalb Grenzwerte/an Grenzwert 1) | EIN/AUS | 1 Bit | 1.1 switch | CT |
| 21 | Eingang A (innerhalb Grenzwerte/an Grenzwert 1) | Alarm | 1 Bit | 16.0 Character String (ASCII) | CT |
| 21 | Eingang A (innerhalb Grenzwerte/an Grenzwert 1) | Jalousie | 1 Bit | 1.8 up/down | CT |
| 21 | Eingang A (innerhalb Grenzwerte/an Grenzwert 1) | Szene aufrufen | 1 Byte | 16.0 Character String (ASCII) | CT |
| 21 | Eingang A (innerhalb Grenzwerte/an Grenzwert 1) | Sequenz Start/Stopp | 1 Bit | 1.10 start/stop | CT |
| 21 | Eingang A (innerhalb Grenzwerte/an Grenzwert 1) | Wert 0…100% | 1 Byte | 5.1 percentage (0..100%) | CT |
| 21 | Eingang A (innerhalb Grenzwerte/an Grenzwert 1) | Wert | 1 Byte | 16.0 Character String (ASCII) | CT |
| 21 | Eingang A (innerhalb Grenzwerte/an Grenzwert 1) | Wert | 2 Bytes | 7.1 pulses | CT |
| 21 | Eingang A (innerhalb Grenzwerte/an Grenzwert 1) | String (14 Bytes) | 14 Bytes | 16.0 Character String (ASCII) | CT |
| 21 | Logik Block A Ausgang 6 | EIN/AUS | 1 Bit | 1.1 switch | CWTU |
| 21 | Logik Block A Ausgang 6 | Alarm | 1 Bit | 16.0 Character String (ASCII) | CWTU |
| 21 | Logik Block A Ausgang 6 | Jalousie | 1 Bit | 1.8 up/down | CWTU |
| 21 | Logik Block A Ausgang 6 | Szene aufrufen | 1 Byte | 16.0 Character String (ASCII) | CWTU |
| 21 | Logik Block A Ausgang 6 | Sequenz | 1 Bit | 1.10 start/stop | CWTU |
| 21 | Logik Block A Ausgang 6 | Wert (0…100%) | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 21 | Logik Block A Ausgang 6 | Wert | 1 Byte | 16.0 Character String (ASCII) | CWTU |
| 21 | Logik Block A Ausgang 6 | Wert | 2 Bytes | 7.1 pulses | CWTU |
| 21 | Logik Block A Ausgang 6 | String (14 Bytes) | 14 Bytes | 16.0 Character String (ASCII) | CT |
| 21 | Ausgang A | Alarm Treppenhauslicht | 1 Bit | 16.0 Character String (ASCII) | CRT |
| 22 | Eingang A (geöffnet) | EIN/AUS | 1 Bit | 1.1 switch | CT |
| 22 | Eingang A (geöffnet) | Jalousie | 1 Bit | 1.8 up/down | CT |
| 22 | Eingang A (geöffnet) | Szene aufrufen | 1 Byte | 16.0 Character String (ASCII) | CT |
| 22 | Eingang A (geöffnet) | Sequenz Start/Stopp | 1 Bit | 1.10 start/stop | CT |
| 22 | Eingang A (geöffnet) | Wert 0…100% | 1 Byte | 5.1 percentage (0..100%) | CT |
| 22 | Eingang A (geöffnet) | Wert | 1 Byte | 16.0 Character String (ASCII) | CT |
| 22 | Eingang A (geöffnet) | Wert | 2 Bytes | 7.1 pulses | CT |
| 22 | Eingang A (geöffnet) | String (14 Bytes) | 14 Bytes | 16.0 Character String (ASCII) | CT |
| 22 | Eingang A (langer Tastendruck) | EIN/AUS | 1 Bit | 1.1 switch | CT |
| 22 | Eingang A (langer Tastendruck) | Jalousie | 1 Bit | 1.8 up/down | CT |
| 22 | Eingang A (langer Tastendruck) | Szene aufrufen | 1 Byte | 16.0 Character String (ASCII) | CT |
| 22 | Eingang A (langer Tastendruck) | Sequenz Start/Stopp | 1 Bit | 1.10 start/stop | CT |
| 22 | Eingang A (langer Tastendruck) | Wert 0…100% | 1 Byte | 5.1 percentage (0..100%) | CT |
| 22 | Eingang A (langer Tastendruck) | Wert | 1 Byte | 16.0 Character String (ASCII) | CT |
| 22 | Eingang A (langer Tastendruck) | Wert | 2 Bytes | 7.1 pulses | CT |
| 22 | Eingang A (langer Tastendruck) | String (14 Bytes) | 14 Bytes | 16.0 Character String (ASCII) | CT |
| 22 | Eingang A (innerhalb Grenzwerte/an Grenzwert 1) | EIN/AUS | 1 Bit | 1.1 switch | CT |
| 22 | Eingang A (innerhalb Grenzwerte/an Grenzwert 1) | Alarm | 1 Bit | 16.0 Character String (ASCII) | CT |
| 22 | Eingang A (innerhalb Grenzwerte/an Grenzwert 1) | Jalousie | 1 Bit | 1.8 up/down | CT |
| 22 | Eingang A (innerhalb Grenzwerte/an Grenzwert 1) | Szene aufrufen | 1 Byte | 16.0 Character String (ASCII) | CT |
| 22 | Eingang A (innerhalb Grenzwerte/an Grenzwert 1) | Sequenz Start/Stopp | 1 Bit | 1.10 start/stop | CT |
| 22 | Eingang A (innerhalb Grenzwerte/an Grenzwert 1) | Wert 0…100% | 1 Byte | 5.1 percentage (0..100%) | CT |
| 22 | Eingang A (innerhalb Grenzwerte/an Grenzwert 1) | Wert | 1 Byte | 16.0 Character String (ASCII) | CT |
| 22 | Eingang A (innerhalb Grenzwerte/an Grenzwert 1) | Wert | 2 Bytes | 7.1 pulses | CT |
| 22 | Eingang A (innerhalb Grenzwerte/an Grenzwert 1) | String (14 Bytes) | 14 Bytes | 16.0 Character String (ASCII) | CT |
| 22 | Logik Block A Ausgang 7 | EIN/AUS | 1 Bit | 1.1 switch | CWTU |
| 22 | Logik Block A Ausgang 7 | Alarm | 1 Bit | 16.0 Character String (ASCII) | CWTU |
| 22 | Logik Block A Ausgang 7 | Jalousie | 1 Bit | 1.8 up/down | CWTU |
| 22 | Logik Block A Ausgang 7 | Szene aufrufen | 1 Byte | 16.0 Character String (ASCII) | CWTU |
| 22 | Logik Block A Ausgang 7 | Sequenz | 1 Bit | 1.10 start/stop | CWTU |
| 22 | Logik Block A Ausgang 7 | Wert (0…100%) | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 22 | Logik Block A Ausgang 7 | Wert | 1 Byte | 16.0 Character String (ASCII) | CWTU |
| 22 | Logik Block A Ausgang 7 | Wert | 2 Bytes | 7.1 pulses | CWTU |
| 22 | Logik Block A Ausgang 7 | String (14 Bytes) | 14 Bytes | 16.0 Character String (ASCII) | CT |
| 22 | Ausgang A | Blinken EIN/AUS | 1 Bit | 1.1 switch | CWU |
| 23 | Eingang A (geöffnet) | EIN/AUS | 1 Bit | 1.1 switch | CT |
| 23 | Eingang A (geöffnet) | Jalousie | 1 Bit | 1.8 up/down | CT |
| 23 | Eingang A (geöffnet) | Szene aufrufen | 1 Byte | 16.0 Character String (ASCII) | CT |
| 23 | Eingang A (geöffnet) | Sequenz Start/Stopp | 1 Bit | 1.10 start/stop | CT |
| 23 | Eingang A (geöffnet) | Wert 0…100% | 1 Byte | 5.1 percentage (0..100%) | CT |
| 23 | Eingang A (geöffnet) | Wert | 1 Byte | 16.0 Character String (ASCII) | CT |
| 23 | Eingang A (geöffnet) | Wert | 2 Bytes | 7.1 pulses | CT |
| 23 | Eingang A (geöffnet) | String (14 Bytes) | 14 Bytes | 16.0 Character String (ASCII) | CT |
| 23 | Eingang A (langer Tastendruck) | EIN/AUS | 1 Bit | 1.1 switch | CT |
| 23 | Eingang A (langer Tastendruck) | Jalousie | 1 Bit | 1.8 up/down | CT |
| 23 | Eingang A (langer Tastendruck) | Szene aufrufen | 1 Byte | 16.0 Character String (ASCII) | CT |
| 23 | Eingang A (langer Tastendruck) | Sequenz Start/Stopp | 1 Bit | 1.10 start/stop | CT |
| 23 | Eingang A (langer Tastendruck) | Wert 0…100% | 1 Byte | 5.1 percentage (0..100%) | CT |
| 23 | Eingang A (langer Tastendruck) | Wert | 1 Byte | 16.0 Character String (ASCII) | CT |
| 23 | Eingang A (langer Tastendruck) | Wert | 2 Bytes | 7.1 pulses | CT |
| 23 | Eingang A (langer Tastendruck) | String (14 Bytes) | 14 Bytes | 16.0 Character String (ASCII) | CT |
| 23 | Eingang A (außerhalb Grenzwerte/an Grenzwert 1) | EIN/AUS | 1 Bit | 1.1 switch | CT |
| 23 | Eingang A (außerhalb Grenzwerte/an Grenzwert 1) | Alarm | 1 Bit | 16.0 Character String (ASCII) | CT |
| 23 | Eingang A (außerhalb Grenzwerte/an Grenzwert 1) | Jalousie | 1 Bit | 1.8 up/down | CT |
| 23 | Eingang A (außerhalb Grenzwerte/an Grenzwert 1) | Szene aufrufen | 1 Byte | 16.0 Character String (ASCII) | CT |
| 23 | Eingang A (außerhalb Grenzwerte/an Grenzwert 1) | Sequenz Start/Stopp | 1 Bit | 1.10 start/stop | CT |
| 23 | Eingang A (außerhalb Grenzwerte/an Grenzwert 1) | Wert 0…100% | 1 Byte | 5.1 percentage (0..100%) | CT |
| 23 | Eingang A (außerhalb Grenzwerte/an Grenzwert 1) | Wert | 1 Byte | 16.0 Character String (ASCII) | CT |
| 23 | Eingang A (außerhalb Grenzwerte/an Grenzwert 1) | Wert | 2 Bytes | 7.1 pulses | CT |
| 23 | Eingang A (außerhalb Grenzwerte/an Grenzwert 1) | String (14 Bytes) | 14 Bytes | 16.0 Character String (ASCII) | CT |
| 23 | Logik Block A Ausgang 8 | EIN/AUS | 1 Bit | 1.1 switch | CWTU |
| 23 | Logik Block A Ausgang 8 | Alarm | 1 Bit | 16.0 Character String (ASCII) | CWTU |
| 23 | Logik Block A Ausgang 8 | Jalousie | 1 Bit | 1.8 up/down | CWTU |
| 23 | Logik Block A Ausgang 8 | Szene aufrufen | 1 Byte | 16.0 Character String (ASCII) | CWTU |
| 23 | Logik Block A Ausgang 8 | Sequenz | 1 Bit | 1.10 start/stop | CWTU |
| 23 | Logik Block A Ausgang 8 | Wert (0…100%) | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 23 | Logik Block A Ausgang 8 | Wert | 1 Byte | 16.0 Character String (ASCII) | CWTU |
| 23 | Logik Block A Ausgang 8 | Wert | 2 Bytes | 7.1 pulses | CWTU |
| 23 | Logik Block A Ausgang 8 | String (14 Bytes) | 14 Bytes | 16.0 Character String (ASCII) | CT |
| 23 | Ausgang A | Szene aufrufen | 1 Byte | 16.0 Character String (ASCII) | CWU |
| 24 | Eingang A (geöffnet) | EIN/AUS | 1 Bit | 1.1 switch | CT |
| 24 | Eingang A (geöffnet) | Jalousie | 1 Bit | 1.8 up/down | CT |
| 24 | Eingang A (geöffnet) | Szene aufrufen | 1 Byte | 16.0 Character String (ASCII) | CT |
| 24 | Eingang A (geöffnet) | Sequenz Start/Stopp | 1 Bit | 1.10 start/stop | CT |
| 24 | Eingang A (geöffnet) | Wert 0…100% | 1 Byte | 5.1 percentage (0..100%) | CT |
| 24 | Eingang A (geöffnet) | Wert | 1 Byte | 16.0 Character String (ASCII) | CT |
| 24 | Eingang A (geöffnet) | Wert | 2 Bytes | 7.1 pulses | CT |
| 24 | Eingang A (geöffnet) | String (14 Bytes) | 14 Bytes | 16.0 Character String (ASCII) | CT |
| 24 | Eingang A (langer Tastendruck) | EIN/AUS | 1 Bit | 1.1 switch | CT |
| 24 | Eingang A (langer Tastendruck) | Jalousie | 1 Bit | 1.8 up/down | CT |
| 24 | Eingang A (langer Tastendruck) | Szene aufrufen | 1 Byte | 16.0 Character String (ASCII) | CT |
| 24 | Eingang A (langer Tastendruck) | Sequenz Start/Stopp | 1 Bit | 1.10 start/stop | CT |
| 24 | Eingang A (langer Tastendruck) | Wert 0…100% | 1 Byte | 5.1 percentage (0..100%) | CT |
| 24 | Eingang A (langer Tastendruck) | Wert | 1 Byte | 16.0 Character String (ASCII) | CT |
| 24 | Eingang A (langer Tastendruck) | Wert | 2 Bytes | 7.1 pulses | CT |
| 24 | Eingang A (langer Tastendruck) | String (14 Bytes) | 14 Bytes | 16.0 Character String (ASCII) | CT |
| 24 | Eingang A (außerhalb Grenzwerte/an Grenzwert 1) | EIN/AUS | 1 Bit | 1.1 switch | CT |
| 24 | Eingang A (außerhalb Grenzwerte/an Grenzwert 1) | Alarm | 1 Bit | 16.0 Character String (ASCII) | CT |
| 24 | Eingang A (außerhalb Grenzwerte/an Grenzwert 1) | Jalousie | 1 Bit | 1.8 up/down | CT |
| 24 | Eingang A (außerhalb Grenzwerte/an Grenzwert 1) | Szene aufrufen | 1 Byte | 16.0 Character String (ASCII) | CT |
| 24 | Eingang A (außerhalb Grenzwerte/an Grenzwert 1) | Sequenz Start/Stopp | 1 Bit | 1.10 start/stop | CT |
| 24 | Eingang A (außerhalb Grenzwerte/an Grenzwert 1) | Wert 0…100% | 1 Byte | 5.1 percentage (0..100%) | CT |
| 24 | Eingang A (außerhalb Grenzwerte/an Grenzwert 1) | Wert | 1 Byte | 16.0 Character String (ASCII) | CT |
| 24 | Eingang A (außerhalb Grenzwerte/an Grenzwert 1) | Wert | 2 Bytes | 7.1 pulses | CT |
| 24 | Eingang A (außerhalb Grenzwerte/an Grenzwert 1) | String (14 Bytes) | 14 Bytes | 16.0 Character String (ASCII) | CT |
| 24 | Logik Block A Ausgang 9 | EIN/AUS | 1 Bit | 1.1 switch | CWTU |
| 24 | Logik Block A Ausgang 9 | Alarm | 1 Bit | 16.0 Character String (ASCII) | CWTU |
| 24 | Logik Block A Ausgang 9 | Jalousie | 1 Bit | 1.8 up/down | CWTU |
| 24 | Logik Block A Ausgang 9 | Szene aufrufen | 1 Byte | 16.0 Character String (ASCII) | CWTU |
| 24 | Logik Block A Ausgang 9 | Sequenz | 1 Bit | 1.10 start/stop | CWTU |
| 24 | Logik Block A Ausgang 9 | Wert (0…100%) | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 24 | Logik Block A Ausgang 9 | Wert | 1 Byte | 16.0 Character String (ASCII) | CWTU |
| 24 | Logik Block A Ausgang 9 | Wert | 2 Bytes | 7.1 pulses | CWTU |
| 24 | Logik Block A Ausgang 9 | String (14 Bytes) | 14 Bytes | 16.0 Character String (ASCII) | CT |
| 24 | Ausgang A | Dimmen | 4 Bit | 3.7 dimming control | CWU |
| 25 | Eingang A (geöffnet) | EIN/AUS | 1 Bit | 1.1 switch | CT |
| 25 | Eingang A (geöffnet) | Jalousie | 1 Bit | 1.8 up/down | CT |
| 25 | Eingang A (geöffnet) | Szene aufrufen | 1 Byte | 16.0 Character String (ASCII) | CT |
| 25 | Eingang A (geöffnet) | Sequenz Start/Stopp | 1 Bit | 1.10 start/stop | CT |
| 25 | Eingang A (geöffnet) | Wert 0…100% | 1 Byte | 5.1 percentage (0..100%) | CT |
| 25 | Eingang A (geöffnet) | Wert | 1 Byte | 16.0 Character String (ASCII) | CT |
| 25 | Eingang A (geöffnet) | Wert | 2 Bytes | 7.1 pulses | CT |
| 25 | Eingang A (geöffnet) | String (14 Bytes) | 14 Bytes | 16.0 Character String (ASCII) | CT |
| 25 | Eingang A (langer Tastendruck) | EIN/AUS | 1 Bit | 1.1 switch | CT |
| 25 | Eingang A (langer Tastendruck) | Jalousie | 1 Bit | 1.8 up/down | CT |
| 25 | Eingang A (langer Tastendruck) | Szene aufrufen | 1 Byte | 16.0 Character String (ASCII) | CT |
| 25 | Eingang A (langer Tastendruck) | Sequenz Start/Stopp | 1 Bit | 1.10 start/stop | CT |
| 25 | Eingang A (langer Tastendruck) | Wert 0…100% | 1 Byte | 5.1 percentage (0..100%) | CT |
| 25 | Eingang A (langer Tastendruck) | Wert | 1 Byte | 16.0 Character String (ASCII) | CT |
| 25 | Eingang A (langer Tastendruck) | Wert | 2 Bytes | 7.1 pulses | CT |
| 25 | Eingang A (langer Tastendruck) | String (14 Bytes) | 14 Bytes | 16.0 Character String (ASCII) | CT |
| 25 | Eingang A (außerhalb Grenzwerte/an Grenzwert 1) | EIN/AUS | 1 Bit | 1.1 switch | CT |
| 25 | Eingang A (außerhalb Grenzwerte/an Grenzwert 1) | Alarm | 1 Bit | 16.0 Character String (ASCII) | CT |
| 25 | Eingang A (außerhalb Grenzwerte/an Grenzwert 1) | Jalousie | 1 Bit | 1.8 up/down | CT |
| 25 | Eingang A (außerhalb Grenzwerte/an Grenzwert 1) | Szene aufrufen | 1 Byte | 16.0 Character String (ASCII) | CT |
| 25 | Eingang A (außerhalb Grenzwerte/an Grenzwert 1) | Sequenz Start/Stopp | 1 Bit | 1.10 start/stop | CT |
| 25 | Eingang A (außerhalb Grenzwerte/an Grenzwert 1) | Wert 0…100% | 1 Byte | 5.1 percentage (0..100%) | CT |
| 25 | Eingang A (außerhalb Grenzwerte/an Grenzwert 1) | Wert | 1 Byte | 16.0 Character String (ASCII) | CT |
| 25 | Eingang A (außerhalb Grenzwerte/an Grenzwert 1) | Wert | 2 Bytes | 7.1 pulses | CT |
| 25 | Eingang A (außerhalb Grenzwerte/an Grenzwert 1) | String (14 Bytes) | 14 Bytes | 16.0 Character String (ASCII) | CT |
| 25 | Logik Block A Ausgang 10 | EIN/AUS | 1 Bit | 1.1 switch | CWTU |
| 25 | Logik Block A Ausgang 10 | Alarm | 1 Bit | 16.0 Character String (ASCII) | CWTU |
| 25 | Logik Block A Ausgang 10 | Jalousie | 1 Bit | 1.8 up/down | CWTU |
| 25 | Logik Block A Ausgang 10 | Szene aufrufen | 1 Byte | 16.0 Character String (ASCII) | CWTU |
| 25 | Logik Block A Ausgang 10 | Sequenz | 1 Bit | 1.10 start/stop | CWTU |
| 25 | Logik Block A Ausgang 10 | Wert (0…100%) | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 25 | Logik Block A Ausgang 10 | Wert | 1 Byte | 16.0 Character String (ASCII) | CWTU |
| 25 | Logik Block A Ausgang 10 | Wert | 2 Bytes | 7.1 pulses | CWTU |
| 25 | Logik Block A Ausgang 10 | String (14 Bytes) | 14 Bytes | 16.0 Character String (ASCII) | CT |
| 25 | Ausgang A | Eingang Schwellwertüberwachung | 1 Byte | 16.0 Character String (ASCII) | CWU |
| 25 | Ausgang A | Eingang Schwellwertüberwachung | 2 Bytes | 7.1 pulses | CWU |
| 26 | Eingang A (geöffnet) | EIN/AUS | 1 Bit | 1.1 switch | CT |
| 26 | Eingang A (geöffnet) | Jalousie | 1 Bit | 1.8 up/down | CT |
| 26 | Eingang A (geöffnet) | Szene aufrufen | 1 Byte | 16.0 Character String (ASCII) | CT |
| 26 | Eingang A (geöffnet) | Sequenz Start/Stopp | 1 Bit | 1.10 start/stop | CT |
| 26 | Eingang A (geöffnet) | Wert 0…100% | 1 Byte | 5.1 percentage (0..100%) | CT |
| 26 | Eingang A (geöffnet) | Wert | 1 Byte | 16.0 Character String (ASCII) | CT |
| 26 | Eingang A (geöffnet) | Wert | 2 Bytes | 7.1 pulses | CT |
| 26 | Eingang A (geöffnet) | String (14 Bytes) | 14 Bytes | 16.0 Character String (ASCII) | CT |
| 26 | Eingang A (langer Tastendruck) | EIN/AUS | 1 Bit | 1.1 switch | CT |
| 26 | Eingang A (langer Tastendruck) | Jalousie | 1 Bit | 1.8 up/down | CT |
| 26 | Eingang A (langer Tastendruck) | Szene aufrufen | 1 Byte | 16.0 Character String (ASCII) | CT |
| 26 | Eingang A (langer Tastendruck) | Sequenz Start/Stopp | 1 Bit | 1.10 start/stop | CT |
| 26 | Eingang A (langer Tastendruck) | Wert 0…100% | 1 Byte | 5.1 percentage (0..100%) | CT |
| 26 | Eingang A (langer Tastendruck) | Wert | 1 Byte | 16.0 Character String (ASCII) | CT |
| 26 | Eingang A (langer Tastendruck) | Wert | 2 Bytes | 7.1 pulses | CT |
| 26 | Eingang A (langer Tastendruck) | String (14 Bytes) | 14 Bytes | 16.0 Character String (ASCII) | CT |
| 26 | Eingang A (außerhalb Grenzwerte/an Grenzwert 1) | EIN/AUS | 1 Bit | 1.1 switch | CT |
| 26 | Eingang A (außerhalb Grenzwerte/an Grenzwert 1) | Alarm | 1 Bit | 16.0 Character String (ASCII) | CT |
| 26 | Eingang A (außerhalb Grenzwerte/an Grenzwert 1) | Jalousie | 1 Bit | 1.8 up/down | CT |
| 26 | Eingang A (außerhalb Grenzwerte/an Grenzwert 1) | Szene aufrufen | 1 Byte | 16.0 Character String (ASCII) | CT |
| 26 | Eingang A (außerhalb Grenzwerte/an Grenzwert 1) | Sequenz Start/Stopp | 1 Bit | 1.10 start/stop | CT |
| 26 | Eingang A (außerhalb Grenzwerte/an Grenzwert 1) | Wert 0…100% | 1 Byte | 5.1 percentage (0..100%) | CT |
| 26 | Eingang A (außerhalb Grenzwerte/an Grenzwert 1) | Wert | 1 Byte | 16.0 Character String (ASCII) | CT |
| 26 | Eingang A (außerhalb Grenzwerte/an Grenzwert 1) | Wert | 2 Bytes | 7.1 pulses | CT |
| 26 | Eingang A (außerhalb Grenzwerte/an Grenzwert 1) | String (14 Bytes) | 14 Bytes | 16.0 Character String (ASCII) | CT |
| 26 | Ausgang A | Schwellwert 1 | 1 Byte | 16.0 Character String (ASCII) | CWU |
| 26 | Ausgang A | Schwellwert 1 | 2 Bytes | 7.1 pulses | CWU |
| 27 | Eingang A (geöffnet) | EIN/AUS | 1 Bit | 1.1 switch | CT |
| 27 | Eingang A (geöffnet) | Jalousie | 1 Bit | 1.8 up/down | CT |
| 27 | Eingang A (geöffnet) | Szene aufrufen | 1 Byte | 16.0 Character String (ASCII) | CT |
| 27 | Eingang A (geöffnet) | Sequenz Start/Stopp | 1 Bit | 1.10 start/stop | CT |
| 27 | Eingang A (geöffnet) | Wert 0…100% | 1 Byte | 5.1 percentage (0..100%) | CT |
| 27 | Eingang A (geöffnet) | Wert | 1 Byte | 16.0 Character String (ASCII) | CT |
| 27 | Eingang A (geöffnet) | Wert | 2 Bytes | 7.1 pulses | CT |
| 27 | Eingang A (geöffnet) | String (14 Bytes) | 14 Bytes | 16.0 Character String (ASCII) | CT |
| 27 | Eingang A (langer Tastendruck) | EIN/AUS | 1 Bit | 1.1 switch | CT |
| 27 | Eingang A (langer Tastendruck) | Jalousie | 1 Bit | 1.8 up/down | CT |
| 27 | Eingang A (langer Tastendruck) | Szene aufrufen | 1 Byte | 16.0 Character String (ASCII) | CT |
| 27 | Eingang A (langer Tastendruck) | Sequenz Start/Stopp | 1 Bit | 1.10 start/stop | CT |
| 27 | Eingang A (langer Tastendruck) | Wert 0…100% | 1 Byte | 5.1 percentage (0..100%) | CT |
| 27 | Eingang A (langer Tastendruck) | Wert | 1 Byte | 16.0 Character String (ASCII) | CT |
| 27 | Eingang A (langer Tastendruck) | Wert | 2 Bytes | 7.1 pulses | CT |
| 27 | Eingang A (langer Tastendruck) | String (14 Bytes) | 14 Bytes | 16.0 Character String (ASCII) | CT |
| 27 | Eingang A (außerhalb Grenzwerte/an Grenzwert 1) | EIN/AUS | 1 Bit | 1.1 switch | CT |
| 27 | Eingang A (außerhalb Grenzwerte/an Grenzwert 1) | Alarm | 1 Bit | 16.0 Character String (ASCII) | CT |
| 27 | Eingang A (außerhalb Grenzwerte/an Grenzwert 1) | Jalousie | 1 Bit | 1.8 up/down | CT |
| 27 | Eingang A (außerhalb Grenzwerte/an Grenzwert 1) | Szene aufrufen | 1 Byte | 16.0 Character String (ASCII) | CT |
| 27 | Eingang A (außerhalb Grenzwerte/an Grenzwert 1) | Sequenz Start/Stopp | 1 Bit | 1.10 start/stop | CT |
| 27 | Eingang A (außerhalb Grenzwerte/an Grenzwert 1) | Wert 0…100% | 1 Byte | 5.1 percentage (0..100%) | CT |
| 27 | Eingang A (außerhalb Grenzwerte/an Grenzwert 1) | Wert | 1 Byte | 16.0 Character String (ASCII) | CT |
| 27 | Eingang A (außerhalb Grenzwerte/an Grenzwert 1) | Wert | 2 Bytes | 7.1 pulses | CT |
| 27 | Eingang A (außerhalb Grenzwerte/an Grenzwert 1) | String (14 Bytes) | 14 Bytes | 16.0 Character String (ASCII) | CT |
| 27 | Ausgang A | Schwellwert 2 | 1 Byte | 16.0 Character String (ASCII) | CWU |
| 27 | Ausgang A | Schwellwert 2 | 2 Bytes | 7.1 pulses | CWU |
| 28 | Eingang A (geöffnet) | EIN/AUS | 1 Bit | 1.1 switch | CT |
| 28 | Eingang A (geöffnet) | Jalousie | 1 Bit | 1.8 up/down | CT |
| 28 | Eingang A (geöffnet) | Szene aufrufen | 1 Byte | 16.0 Character String (ASCII) | CT |
| 28 | Eingang A (geöffnet) | Sequenz Start/Stopp | 1 Bit | 1.10 start/stop | CT |
| 28 | Eingang A (geöffnet) | Wert 0…100% | 1 Byte | 5.1 percentage (0..100%) | CT |
| 28 | Eingang A (geöffnet) | Wert | 1 Byte | 16.0 Character String (ASCII) | CT |
| 28 | Eingang A (geöffnet) | Wert | 2 Bytes | 7.1 pulses | CT |
| 28 | Eingang A (geöffnet) | String (14 Bytes) | 14 Bytes | 16.0 Character String (ASCII) | CT |
| 28 | Eingang A (langer Tastendruck) | EIN/AUS | 1 Bit | 1.1 switch | CT |
| 28 | Eingang A (langer Tastendruck) | Jalousie | 1 Bit | 1.8 up/down | CT |
| 28 | Eingang A (langer Tastendruck) | Szene aufrufen | 1 Byte | 16.0 Character String (ASCII) | CT |
| 28 | Eingang A (langer Tastendruck) | Sequenz Start/Stopp | 1 Bit | 1.10 start/stop | CT |
| 28 | Eingang A (langer Tastendruck) | Wert 0…100% | 1 Byte | 5.1 percentage (0..100%) | CT |
| 28 | Eingang A (langer Tastendruck) | Wert | 1 Byte | 16.0 Character String (ASCII) | CT |
| 28 | Eingang A (langer Tastendruck) | Wert | 2 Bytes | 7.1 pulses | CT |
| 28 | Eingang A (langer Tastendruck) | String (14 Bytes) | 14 Bytes | 16.0 Character String (ASCII) | CT |
| 28 | Eingang A (außerhalb Grenzwerte/an Grenzwert 1) | EIN/AUS | 1 Bit | 1.1 switch | CT |
| 28 | Eingang A (außerhalb Grenzwerte/an Grenzwert 1) | Alarm | 1 Bit | 16.0 Character String (ASCII) | CT |
| 28 | Eingang A (außerhalb Grenzwerte/an Grenzwert 1) | Jalousie | 1 Bit | 1.8 up/down | CT |
| 28 | Eingang A (außerhalb Grenzwerte/an Grenzwert 1) | Szene aufrufen | 1 Byte | 16.0 Character String (ASCII) | CT |
| 28 | Eingang A (außerhalb Grenzwerte/an Grenzwert 1) | Sequenz Start/Stopp | 1 Bit | 1.10 start/stop | CT |
| 28 | Eingang A (außerhalb Grenzwerte/an Grenzwert 1) | Wert 0…100% | 1 Byte | 5.1 percentage (0..100%) | CT |
| 28 | Eingang A (außerhalb Grenzwerte/an Grenzwert 1) | Wert | 1 Byte | 16.0 Character String (ASCII) | CT |
| 28 | Eingang A (außerhalb Grenzwerte/an Grenzwert 1) | Wert | 2 Bytes | 7.1 pulses | CT |
| 28 | Eingang A (außerhalb Grenzwerte/an Grenzwert 1) | String (14 Bytes) | 14 Bytes | 16.0 Character String (ASCII) | CT |
| 28 | Ausgang A (PWM) | Heizen | 1 Bit | 1.1 switch | CWU |
| 28 | Ausgang A (PWM) | Heizen | 1 Byte | 16.0 Character String (ASCII) | CWU |
| 29 | Eingang A (geöffnet) | EIN/AUS | 1 Bit | 1.1 switch | CT |
| 29 | Eingang A (geöffnet) | Jalousie | 1 Bit | 1.8 up/down | CT |
| 29 | Eingang A (geöffnet) | Szene aufrufen | 1 Byte | 16.0 Character String (ASCII) | CT |
| 29 | Eingang A (geöffnet) | Sequenz Start/Stopp | 1 Bit | 1.10 start/stop | CT |
| 29 | Eingang A (geöffnet) | Wert 0…100% | 1 Byte | 5.1 percentage (0..100%) | CT |
| 29 | Eingang A (geöffnet) | Wert | 1 Byte | 16.0 Character String (ASCII) | CT |
| 29 | Eingang A (geöffnet) | Wert | 2 Bytes | 7.1 pulses | CT |
| 29 | Eingang A (geöffnet) | String (14 Bytes) | 14 Bytes | 16.0 Character String (ASCII) | CT |
| 29 | Eingang A (langer Tastendruck) | EIN/AUS | 1 Bit | 1.1 switch | CT |
| 29 | Eingang A (langer Tastendruck) | Jalousie | 1 Bit | 1.8 up/down | CT |
| 29 | Eingang A (langer Tastendruck) | Szene aufrufen | 1 Byte | 16.0 Character String (ASCII) | CT |
| 29 | Eingang A (langer Tastendruck) | Sequenz Start/Stopp | 1 Bit | 1.10 start/stop | CT |
| 29 | Eingang A (langer Tastendruck) | Wert 0…100% | 1 Byte | 5.1 percentage (0..100%) | CT |
| 29 | Eingang A (langer Tastendruck) | Wert | 1 Byte | 16.0 Character String (ASCII) | CT |
| 29 | Eingang A (langer Tastendruck) | Wert | 2 Bytes | 7.1 pulses | CT |
| 29 | Eingang A (langer Tastendruck) | String (14 Bytes) | 14 Bytes | 16.0 Character String (ASCII) | CT |
| 29 | Eingang A (außerhalb Grenzwerte/an Grenzwert 1) | EIN/AUS | 1 Bit | 1.1 switch | CT |
| 29 | Eingang A (außerhalb Grenzwerte/an Grenzwert 1) | Alarm | 1 Bit | 16.0 Character String (ASCII) | CT |
| 29 | Eingang A (außerhalb Grenzwerte/an Grenzwert 1) | Jalousie | 1 Bit | 1.8 up/down | CT |
| 29 | Eingang A (außerhalb Grenzwerte/an Grenzwert 1) | Szene aufrufen | 1 Byte | 16.0 Character String (ASCII) | CT |
| 29 | Eingang A (außerhalb Grenzwerte/an Grenzwert 1) | Sequenz Start/Stopp | 1 Bit | 1.10 start/stop | CT |
| 29 | Eingang A (außerhalb Grenzwerte/an Grenzwert 1) | Wert 0…100% | 1 Byte | 5.1 percentage (0..100%) | CT |
| 29 | Eingang A (außerhalb Grenzwerte/an Grenzwert 1) | Wert | 1 Byte | 16.0 Character String (ASCII) | CT |
| 29 | Eingang A (außerhalb Grenzwerte/an Grenzwert 1) | Wert | 2 Bytes | 7.1 pulses | CT |
| 29 | Eingang A (außerhalb Grenzwerte/an Grenzwert 1) | String (14 Bytes) | 14 Bytes | 16.0 Character String (ASCII) | CT |
| 29 | Ausgang A (PWM) | Eingang Temperatur | 2 Bytes | 9.1 temperature (°C) | CWU |
| 30 | Eingang A (geöffnet) | EIN/AUS | 1 Bit | 1.1 switch | CT |
| 30 | Eingang A (geöffnet) | Jalousie | 1 Bit | 1.8 up/down | CT |
| 30 | Eingang A (geöffnet) | Szene aufrufen | 1 Byte | 16.0 Character String (ASCII) | CT |
| 30 | Eingang A (geöffnet) | Sequenz Start/Stopp | 1 Bit | 1.10 start/stop | CT |
| 30 | Eingang A (geöffnet) | Wert 0…100% | 1 Byte | 5.1 percentage (0..100%) | CT |
| 30 | Eingang A (geöffnet) | Wert | 1 Byte | 16.0 Character String (ASCII) | CT |
| 30 | Eingang A (geöffnet) | Wert | 2 Bytes | 7.1 pulses | CT |
| 30 | Eingang A (geöffnet) | String (14 Bytes) | 14 Bytes | 16.0 Character String (ASCII) | CT |
| 30 | Eingang A (langer Tastendruck) | EIN/AUS | 1 Bit | 1.1 switch | CT |
| 30 | Eingang A (langer Tastendruck) | Jalousie | 1 Bit | 1.8 up/down | CT |
| 30 | Eingang A (langer Tastendruck) | Szene aufrufen | 1 Byte | 16.0 Character String (ASCII) | CT |
| 30 | Eingang A (langer Tastendruck) | Sequenz Start/Stopp | 1 Bit | 1.10 start/stop | CT |
| 30 | Eingang A (langer Tastendruck) | Wert 0…100% | 1 Byte | 5.1 percentage (0..100%) | CT |
| 30 | Eingang A (langer Tastendruck) | Wert | 1 Byte | 16.0 Character String (ASCII) | CT |
| 30 | Eingang A (langer Tastendruck) | Wert | 2 Bytes | 7.1 pulses | CT |
| 30 | Eingang A (langer Tastendruck) | String (14 Bytes) | 14 Bytes | 16.0 Character String (ASCII) | CT |
| 30 | Eingang A (außerhalb Grenzwerte/an Grenzwert 1) | EIN/AUS | 1 Bit | 1.1 switch | CT |
| 30 | Eingang A (außerhalb Grenzwerte/an Grenzwert 1) | Alarm | 1 Bit | 16.0 Character String (ASCII) | CT |
| 30 | Eingang A (außerhalb Grenzwerte/an Grenzwert 1) | Jalousie | 1 Bit | 1.8 up/down | CT |
| 30 | Eingang A (außerhalb Grenzwerte/an Grenzwert 1) | Szene aufrufen | 1 Byte | 16.0 Character String (ASCII) | CT |
| 30 | Eingang A (außerhalb Grenzwerte/an Grenzwert 1) | Sequenz Start/Stopp | 1 Bit | 1.10 start/stop | CT |
| 30 | Eingang A (außerhalb Grenzwerte/an Grenzwert 1) | Wert 0…100% | 1 Byte | 5.1 percentage (0..100%) | CT |
| 30 | Eingang A (außerhalb Grenzwerte/an Grenzwert 1) | Wert | 1 Byte | 16.0 Character String (ASCII) | CT |
| 30 | Eingang A (außerhalb Grenzwerte/an Grenzwert 1) | Wert | 2 Bytes | 7.1 pulses | CT |
| 30 | Eingang A (außerhalb Grenzwerte/an Grenzwert 1) | String (14 Bytes) | 14 Bytes | 16.0 Character String (ASCII) | CT |
| 30 | Ausgang A (PWM) | Alarm Grenzwert 1 | 1 Bit | 16.0 Character String (ASCII) | CRT |
| 31 | Eingang A (außerhalb Grenzwerte/an Grenzwert 1) | EIN/AUS | 1 Bit | 1.1 switch | CT |
| 31 | Eingang A (außerhalb Grenzwerte/an Grenzwert 1) | Alarm | 1 Bit | 16.0 Character String (ASCII) | CT |
| 31 | Eingang A (außerhalb Grenzwerte/an Grenzwert 1) | Jalousie | 1 Bit | 1.8 up/down | CT |
| 31 | Eingang A (außerhalb Grenzwerte/an Grenzwert 1) | Szene aufrufen | 1 Byte | 16.0 Character String (ASCII) | CT |
| 31 | Eingang A (außerhalb Grenzwerte/an Grenzwert 1) | Sequenz Start/Stopp | 1 Bit | 1.10 start/stop | CT |
| 31 | Eingang A (außerhalb Grenzwerte/an Grenzwert 1) | Wert 0…100% | 1 Byte | 5.1 percentage (0..100%) | CT |
| 31 | Eingang A (außerhalb Grenzwerte/an Grenzwert 1) | Wert | 1 Byte | 16.0 Character String (ASCII) | CT |
| 31 | Eingang A (außerhalb Grenzwerte/an Grenzwert 1) | Wert | 2 Bytes | 7.1 pulses | CT |
| 31 | Eingang A (außerhalb Grenzwerte/an Grenzwert 1) | String (14 Bytes) | 14 Bytes | 16.0 Character String (ASCII) | CT |
| 31 | Ausgang A (PWM) | Alarm Grenzwert 2 | 1 Bit | 16.0 Character String (ASCII) | CRT |
| 32 | Eingang A (außerhalb Grenzwerte/an Grenzwert 1) | EIN/AUS | 1 Bit | 1.1 switch | CT |
| 32 | Eingang A (außerhalb Grenzwerte/an Grenzwert 1) | Alarm | 1 Bit | 16.0 Character String (ASCII) | CT |
| 32 | Eingang A (außerhalb Grenzwerte/an Grenzwert 1) | Jalousie | 1 Bit | 1.8 up/down | CT |
| 32 | Eingang A (außerhalb Grenzwerte/an Grenzwert 1) | Szene aufrufen | 1 Byte | 16.0 Character String (ASCII) | CT |
| 32 | Eingang A (außerhalb Grenzwerte/an Grenzwert 1) | Sequenz Start/Stopp | 1 Bit | 1.10 start/stop | CT |
| 32 | Eingang A (außerhalb Grenzwerte/an Grenzwert 1) | Wert 0…100% | 1 Byte | 5.1 percentage (0..100%) | CT |
| 32 | Eingang A (außerhalb Grenzwerte/an Grenzwert 1) | Wert | 1 Byte | 16.0 Character String (ASCII) | CT |
| 32 | Eingang A (außerhalb Grenzwerte/an Grenzwert 1) | Wert | 2 Bytes | 7.1 pulses | CT |
| 32 | Eingang A (außerhalb Grenzwerte/an Grenzwert 1) | String (14 Bytes) | 14 Bytes | 16.0 Character String (ASCII) | CT |
| 32 | Ausgang A (PWM) | Zwangsführung | 1 Bit | 1.1 switch | CWU |
| 33 | Ausgang A | LED Helligkeit bei EIN | 1 Byte | 5.1 percentage (0..100%) | CWU |
| 33 | Logik Block A LED Ausgang | LED Helligkeit bei EIN | 1 Byte | 5.1 percentage (0..100%) | CWU |
| 34 | Ausgang A | LED EIN/AUS | 1 Bit | 1.1 switch | CWU |
| 34 | Logik Block A LED Ausgang | LED EIN/AUS | 1 Bit | 1.1 switch | CWU |
| 35 | Ausgang A | LED Helligkeit | 1 Byte | 5.1 percentage (0..100%) | CWU |
| 35 | Logik Block A LED Ausgang | LED Helligkeit | 1 Byte | 5.1 percentage (0..100%) | CWU |
| 36 | Ausgang A | Status LED EIN/AUS | 1 Bit | 1.1 switch | CRT |
| 36 | Logik Block A LED Ausgang | Status LED EIN/AUS | 1 Bit | 1.1 switch | CRT |
| 37 | Ausgang A | Status LED Helligkeit | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 37 | Logik Block A LED Ausgang | Status LED Helligkeit | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 38 | X | X | 1 Bit | CRWTU | |
| 39 | X | X | 1 Bit | CRWTU | |
| 39 | Logik Block A | Sperren | 1 Bit | 1.3 enable | CWU |
| 40 | Eingang B | Sperren | 1 Bit | 1.3 enable | CW |
| 40 | Eingang B | Temperatur | 2 Bytes | 9.1 temperature (°C) | CRT |
| 40 | Logik Block B | Status Eingang EIN/AUS | 1 Bit | 1.2 boolean | CRT |
| 40 | Logik Block B | Temperatur | 2 Bytes | 9.1 temperature (°C) | CRT |
| 40 | Ausgang B | Ausgang | 1 Bit | 1.1 switch | CWU |
| 41 | Eingang B | EIN/AUS | 1 Bit | 1.1 switch | CWTU |
| 41 | Eingang B (kurzer Tastendruck) | EIN/AUS | 1 Bit | 1.1 switch | CWTU |
| 41 | Eingang B (geschlossen) | Schritt auf | 1 Bit | 16.0 Character String (ASCII) | CWTU |
| 41 | Eingang B (geschlossen) | Schritt ab | 1 Bit | 16.0 Character String (ASCII) | CWTU |
| 41 | Eingang B (geschlossen) | Schritt auf/ab abwechselnd | 1 Bit | 16.0 Character String (ASCII) | CWTU |
| 41 | Eingang B (geschlossen) | Auf | 1 Bit | 1.8 up/down | CWTU |
| 41 | Eingang B (geschlossen) | Ab | 1 Bit | 1.8 up/down | CWTU |
| 41 | Eingang B (geschlossen) | Auf/ab abwechselnd | 1 Bit | 1.8 up/down | CWTU |
| 41 | Eingang B (kurzer Tastendruck) | Schritt auf | 1 Bit | 16.0 Character String (ASCII) | CWTU |
| 41 | Eingang B (kurzer Tastendruck) | Schritt ab | 1 Bit | 16.0 Character String (ASCII) | CWTU |
| 41 | Eingang B (kurzer Tastendruck) | Schritt auf/ab abwechselnd | 1 Bit | 16.0 Character String (ASCII) | CWTU |
| 41 | Eingang B (kurzer Tastendruck) | Auf | 1 Bit | 1.8 up/down | CWTU |
| 41 | Eingang B (kurzer Tastendruck) | Ab | 1 Bit | 1.8 up/down | CWTU |
| 41 | Eingang B (kurzer Tastendruck) | Auf/ab abwechselnd | 1 Bit | 1.8 up/down | CWTU |
| 41 | Eingang B | Szene aufrufen | 1 Byte | 16.0 Character String (ASCII) | CWTU |
| 41 | Eingang B (kurzer Tastendruck) | Szene aufrufen | 1 Byte | 16.0 Character String (ASCII) | CWTU |
| 41 | Eingang B | Sequenz | 1 Bit | 1.10 start/stop | CWTU |
| 41 | Eingang B (kurzer Tastendruck) | Sequenz | 1 Bit | 1.10 start/stop | CWTU |
| 41 | Eingang B | 0…100% | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 41 | Eingang B (kurzer Tastendruck) | 0…100% | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 41 | Eingang B (geschlossen) | Wert | 1 Byte | 16.0 Character String (ASCII) | CWTU |
| 41 | Eingang B (geschlossen) | Wert | 2 Bytes | 7.1 pulses | CWTU |
| 41 | Eingang B (kurzer Tastendruck) | Wert | 1 Byte | 16.0 Character String (ASCII) | CWTU |
| 41 | Eingang B (kurzer Tastendruck) | Wert | 2 Bytes | 7.1 pulses | CWTU |
| 41 | Eingang B | String (14 Bytes) | 14 Bytes | 16.0 Character String (ASCII) | CT |
| 41 | Eingang B (kurzer Tastendruck) | String (14 Bytes) | 14 Bytes | 16.0 Character String (ASCII) | CT |
| 41 | Eingang B (geschlossen) | Zwangsführung | 2 Bit | 2.1 switch control | CWTU |
| 41 | Eingang B (geschlossen) | Wert | 2 Bytes | 8.1 pulses difference | CWTU |
| 41 | Eingang B (geschlossen) | Wert | 2 Bytes | 9.1 temperature (°C) | CWTU |
| 41 | Eingang B (geschlossen) | Wert | 4 Bytes | 12.1 counter pulses (unsigned) | CWTU |
| 41 | Eingang B (kurzer Tastendruck) | Zwangsführung | 2 Bit | 2.1 switch control | CWTU |
| 41 | Eingang B (kurzer Tastendruck) | Wert | 2 Bytes | 8.1 pulses difference | CWTU |
| 41 | Eingang B (kurzer Tastendruck) | Wert | 2 Bytes | 9.1 temperature (°C) | CWTU |
| 41 | Eingang B (kurzer Tastendruck) | Wert | 4 Bytes | 12.1 counter pulses (unsigned) | CWTU |
| 41 | Eingang B | Zählerstand | 1 Byte | 5.10 counter pulses (0..255) | CWTU |
| 41 | Eingang B | Zählerstand | 2 Bytes | 7.1 pulses | CWTU |
| 41 | Eingang B | Zählerstand | 4 Bytes | 12.1 counter pulses (unsigned) | CWTU |
| 41 | Eingang B (geschlossen) | EIN/AUS | 1 Bit | 1.1 switch | CT |
| 41 | Eingang B (geschlossen) | Jalousie | 1 Bit | 1.8 up/down | CT |
| 41 | Eingang B (geschlossen) | Szene aufrufen | 1 Byte | 16.0 Character String (ASCII) | CT |
| 41 | Eingang B (geschlossen) | Sequenz Start/Stopp | 1 Bit | 1.10 start/stop | CT |
| 41 | Eingang B (geschlossen) | Wert 0…100% | 1 Byte | 5.1 percentage (0..100%) | CT |
| 41 | Eingang B (geschlossen) | Wert | 1 Byte | 16.0 Character String (ASCII) | CT |
| 41 | Eingang B (geschlossen) | Wert | 2 Bytes | 7.1 pulses | CT |
| 41 | Eingang B (geschlossen) | String (14 Bytes) | 14 Bytes | 16.0 Character String (ASCII) | CT |
| 41 | Eingang B (kurzer Tastendruck) | EIN/AUS | 1 Bit | 1.1 switch | CT |
| 41 | Eingang B (kurzer Tastendruck) | Jalousie | 1 Bit | 1.8 up/down | CT |
| 41 | Eingang B (kurzer Tastendruck) | Szene aufrufen | 1 Byte | 16.0 Character String (ASCII) | CT |
| 41 | Eingang B (kurzer Tastendruck) | Sequenz Start/Stopp | 1 Bit | 1.10 start/stop | CT |
| 41 | Eingang B (kurzer Tastendruck) | Wert 0…100% | 1 Byte | 5.1 percentage (0..100%) | CT |
| 41 | Eingang B (kurzer Tastendruck) | Wert | 1 Byte | 16.0 Character String (ASCII) | CT |
| 41 | Eingang B (kurzer Tastendruck) | Wert | 2 Bytes | 7.1 pulses | CT |
| 41 | Eingang B | Alarm | 1 Bit | 16.0 Character String (ASCII) | CWTU |
| 41 | Eingang B | Auf/Ab | 1 Bit | 1.8 up/down | CWTU |
| 41 | Eingang B (innerhalb/außerhalb Grenzwerte) | Wert | 1 Byte | 16.0 Character String (ASCII) | CWTU |
| 41 | Eingang B (innerhalb/außerhalb Grenzwerte) | Wert | 2 Bytes | 7.1 pulses | CWTU |
| 41 | Eingang B (an Grenzwert 1/2) | Wert | 1 Byte | 16.0 Character String (ASCII) | CWTU |
| 41 | Eingang B (an Grenzwert 1/2) | Wert | 2 Bytes | 7.1 pulses | CWTU |
| 41 | Eingang B (innerhalb Grenzwerte/an Grenzwert 1) | Zwangsführung | 2 Bit | 2.1 switch control | CWTU |
| 41 | Eingang B (innerhalb Grenzwerte/an Grenzwert 1) | Wert | 1 Byte | 16.0 Character String (ASCII) | CWTU |
| 41 | Eingang B (innerhalb Grenzwerte/an Grenzwert 1) | Wert | 2 Bytes | 8.1 pulses difference | CWTU |
| 41 | Eingang B (innerhalb Grenzwerte/an Grenzwert 1) | Wert | 2 Bytes | 7.1 pulses | CWTU |
| 41 | Eingang B (innerhalb Grenzwerte/an Grenzwert 1) | Wert | 2 Bytes | 9.1 temperature (°C) | CWTU |
| 41 | Eingang B (innerhalb Grenzwerte/an Grenzwert 1) | Wert | 4 Bytes | 12.1 counter pulses (unsigned) | CWTU |
| 41 | Eingang B | Grenzwert 1 | 2 Bytes | 9.1 temperature (°C) | CWU |
| 41 | Logik Block B | Eingang 1 | 1 Bit | 1.1 switch | CWU |
| 41 | Logik Block B | Eingang 1 | 1 Byte | 16.0 Character String (ASCII) | CWU |
| 41 | Logik Block B | Eingang 1 | 2 Bytes | 7.1 pulses | CWU |
| 41 | Logik Block B | Eingang 1 | 2 Bytes | DPT.9 | CWU |
| 41 | Logik Block B | Eingang 1 | 4 Bytes | 12.1 counter pulses (unsigned) | CWU |
| 41 | Ausgang B | Dimmen | 4 Bit | 3.7 dimming control | CWU |
| 42 | Eingang B (langer Tastendruck) | EIN/AUS | 1 Bit | 1.1 switch | CWTU |
| 42 | Eingang B | Dimmen | 4 Bit | 3.7 dimming control | CT |
| 42 | Eingang B (langer Tastendruck) | Dimmen | 4 Bit | 3.7 dimming control | CT |
| 42 | Eingang B (geöffnet) | Schritt auf | 1 Bit | 16.0 Character String (ASCII) | CWTU |
| 42 | Eingang B (geöffnet) | Schritt ab | 1 Bit | 16.0 Character String (ASCII) | CWTU |
| 42 | Eingang B (geöffnet) | Schritt auf/ab abwechselnd | 1 Bit | 16.0 Character String (ASCII) | CWTU |
| 42 | Eingang B (geöffnet) | Auf | 1 Bit | 1.8 up/down | CWTU |
| 42 | Eingang B (geöffnet) | Ab | 1 Bit | 1.8 up/down | CWTU |
| 42 | Eingang B (geöffnet) | Auf/ab abwechselnd | 1 Bit | 1.8 up/down | CWTU |
| 42 | Eingang B (langer Tastendruck) | Schritt auf | 1 Bit | 16.0 Character String (ASCII) | CWTU |
| 42 | Eingang B (langer Tastendruck) | Schritt ab | 1 Bit | 16.0 Character String (ASCII) | CWTU |
| 42 | Eingang B (langer Tastendruck) | Schritt auf/ab abwechselnd | 1 Bit | 16.0 Character String (ASCII) | CWTU |
| 42 | Eingang B (langer Tastendruck) | Auf | 1 Bit | 1.8 up/down | CWTU |
| 42 | Eingang B (langer Tastendruck) | Ab | 1 Bit | 1.8 up/down | CWTU |
| 42 | Eingang B (langer Tastendruck) | Auf/ab abwechselnd | 1 Bit | 1.8 up/down | CWTU |
| 42 | Eingang B (langer Tastendruck) | Sequenz | 1 Bit | 1.10 start/stop | CWTU |
| 42 | Eingang B (langer Tastendruck) | 0…100% | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 42 | Eingang B (geöffnet) | Wert | 1 Byte | 16.0 Character String (ASCII) | CWTU |
| 42 | Eingang B (geöffnet) | Wert | 2 Bytes | 7.1 pulses | CWTU |
| 42 | Eingang B (langer Tastendruck) | Wert | 1 Byte | 16.0 Character String (ASCII) | CWTU |
| 42 | Eingang B (langer Tastendruck) | Wert | 2 Bytes | 7.1 pulses | CWTU |
| 42 | Eingang B (langer Tastendruck) | String (14 Bytes) | 14 Bytes | 16.0 Character String (ASCII) | CT |
| 42 | Eingang B (geöffnet) | Zwangsführung | 2 Bit | 2.1 switch control | CWTU |
| 42 | Eingang B (geöffnet) | Wert | 2 Bytes | 8.1 pulses difference | CWTU |
| 42 | Eingang B (geöffnet) | Wert | 2 Bytes | 9.1 temperature (°C) | CWTU |
| 42 | Eingang B (geöffnet) | Wert | 4 Bytes | 12.1 counter pulses (unsigned) | CWTU |
| 42 | Eingang B (langer Tastendruck) | Zwangsführung | 2 Bit | 2.1 switch control | CWTU |
| 42 | Eingang B (langer Tastendruck) | Wert | 2 Bytes | 8.1 pulses difference | CWTU |
| 42 | Eingang B (langer Tastendruck) | Wert | 2 Bytes | 9.1 temperature (°C) | CWTU |
| 42 | Eingang B (langer Tastendruck) | Wert | 4 Bytes | 12.1 counter pulses (unsigned) | CWTU |
| 42 | Eingang B | Zählerende setzen | 1 Byte | 5.10 counter pulses (0..255) | CWU |
| 42 | Eingang B | Zählerende setzen | 2 Bytes | 7.1 pulses | CWU |
| 42 | Eingang B | Zählerende setzen | 4 Bytes | 12.1 counter pulses (unsigned) | CWU |
| 42 | Eingang B (geschlossen) | EIN/AUS | 1 Bit | 1.1 switch | CT |
| 42 | Eingang B (geschlossen) | Jalousie | 1 Bit | 1.8 up/down | CT |
| 42 | Eingang B (geschlossen) | Szene aufrufen | 1 Byte | 16.0 Character String (ASCII) | CT |
| 42 | Eingang B (geschlossen) | Sequenz Start/Stopp | 1 Bit | 1.10 start/stop | CT |
| 42 | Eingang B (geschlossen) | Wert 0…100% | 1 Byte | 5.1 percentage (0..100%) | CT |
| 42 | Eingang B (geschlossen) | Wert | 1 Byte | 16.0 Character String (ASCII) | CT |
| 42 | Eingang B (geschlossen) | Wert | 2 Bytes | 7.1 pulses | CT |
| 42 | Eingang B (geschlossen) | String (14 Bytes) | 14 Bytes | 16.0 Character String (ASCII) | CT |
| 42 | Eingang B (kurzer Tastendruck) | EIN/AUS | 1 Bit | 1.1 switch | CT |
| 42 | Eingang B (kurzer Tastendruck) | Jalousie | 1 Bit | 1.8 up/down | CT |
| 42 | Eingang B (kurzer Tastendruck) | Szene aufrufen | 1 Byte | 16.0 Character String (ASCII) | CT |
| 42 | Eingang B (kurzer Tastendruck) | Sequenz Start/Stopp | 1 Bit | 1.10 start/stop | CT |
| 42 | Eingang B (kurzer Tastendruck) | Wert 0…100% | 1 Byte | 5.1 percentage (0..100%) | CT |
| 42 | Eingang B (kurzer Tastendruck) | Wert | 1 Byte | 16.0 Character String (ASCII) | CT |
| 42 | Eingang B (kurzer Tastendruck) | Wert | 2 Bytes | 7.1 pulses | CT |
| 42 | Eingang B (kurzer Tastendruck) | String (14 Bytes) | 14 Bytes | 16.0 Character String (ASCII) | CT |
| 42 | Eingang B | Grenzwert 1 | 2 Bytes | 9.1 temperature (°C) | CWU |
| 42 | Eingang B (außerhalb Grenzwerte/an Grenzwert 1) | Zwangsführung | 2 Bit | 2.1 switch control | CWTU |
| 42 | Eingang B (außerhalb Grenzwerte/an Grenzwert 1) | Wert | 1 Byte | 16.0 Character String (ASCII) | CWTU |
| 42 | Eingang B (außerhalb Grenzwerte/an Grenzwert 1) | Wert | 2 Bytes | 8.1 pulses difference | CWTU |
| 42 | Eingang B (außerhalb Grenzwerte/an Grenzwert 1) | Wert | 2 Bytes | 7.1 pulses | CWTU |
| 42 | Eingang B (außerhalb Grenzwerte/an Grenzwert 1) | Wert | 2 Bytes | 9.1 temperature (°C) | CWTU |
| 42 | Eingang B (außerhalb Grenzwerte/an Grenzwert 1) | Wert | 4 Bytes | 12.1 counter pulses (unsigned) | CWTU |
| 42 | Eingang B | Grenzwert 2 | 2 Bytes | 9.1 temperature (°C) | CWU |
| 42 | Logik Block B | Eingang 2 | 1 Bit | 1.1 switch | CWU |
| 42 | Logik Block B | Eingang 2 | 1 Byte | 16.0 Character String (ASCII) | CWU |
| 42 | Logik Block B | Eingang 2 | 2 Bytes | 7.1 pulses | CWU |
| 42 | Logik Block B | Eingang 2 | 2 Bytes | DPT.9 | CWU |
| 42 | Logik Block B | Eingang 2 | 4 Bytes | 12.1 counter pulses (unsigned) | CWU |
| 42 | Ausgang B | Dimmwert | 1 Byte | 5.1 percentage (0..100%) | CWU |
| 43 | Eingang B | Zähler setzen | 1 Byte | 5.10 counter pulses (0..255) | CWU |
| 43 | Eingang B | Zähler setzen | 2 Bytes | 7.1 pulses | CWU |
| 43 | Eingang B | Zähler setzen | 4 Bytes | 12.1 counter pulses (unsigned) | CWU |
| 43 | Eingang B (geschlossen) | EIN/AUS | 1 Bit | 1.1 switch | CT |
| 43 | Eingang B (geschlossen) | Jalousie | 1 Bit | 1.8 up/down | CT |
| 43 | Eingang B (geschlossen) | Szene aufrufen | 1 Byte | 16.0 Character String (ASCII) | CT |
| 43 | Eingang B (geschlossen) | Sequenz Start/Stopp | 1 Bit | 1.10 start/stop | CT |
| 43 | Eingang B (geschlossen) | Wert 0…100% | 1 Byte | 5.1 percentage (0..100%) | CT |
| 43 | Eingang B (geschlossen) | Wert | 1 Byte | 16.0 Character String (ASCII) | CT |
| 43 | Eingang B (geschlossen) | Wert | 2 Bytes | 7.1 pulses | CT |
| 43 | Eingang B (geschlossen) | String (14 Bytes) | 14 Bytes | 16.0 Character String (ASCII) | CT |
| 43 | Eingang B (kurzer Tastendruck) | EIN/AUS | 1 Bit | 1.1 switch | CT |
| 43 | Eingang B (kurzer Tastendruck) | Jalousie | 1 Bit | 1.8 up/down | CT |
| 43 | Eingang B (kurzer Tastendruck) | Szene aufrufen | 1 Byte | 16.0 Character String (ASCII) | CT |
| 43 | Eingang B (kurzer Tastendruck) | Sequenz Start/Stopp | 1 Bit | 1.10 start/stop | CT |
| 43 | Eingang B (kurzer Tastendruck) | Wert 0…100% | 1 Byte | 5.1 percentage (0..100%) | CT |
| 43 | Eingang B (kurzer Tastendruck) | Wert | 1 Byte | 16.0 Character String (ASCII) | CT |
| 43 | Eingang B (kurzer Tastendruck) | Wert | 2 Bytes | 7.1 pulses | CT |
| 43 | Eingang B (kurzer Tastendruck) | String (14 Bytes) | 14 Bytes | 16.0 Character String (ASCII) | CT |
| 43 | Eingang B | Grenzwert 2 | 2 Bytes | 9.1 temperature (°C) | CWU |
| 43 | Eingang B | Grenzwert 1 | 2 Bytes | 9.1 temperature (°C) | CWU |
| 43 | Eingang B (innerhalb Grenzwerte/an Grenzwert 1) | EIN/AUS | 1 Bit | 1.1 switch | CT |
| 43 | Eingang B (innerhalb Grenzwerte/an Grenzwert 1) | Alarm | 1 Bit | 16.0 Character String (ASCII) | CT |
| 43 | Eingang B (innerhalb Grenzwerte/an Grenzwert 1) | Jalousie | 1 Bit | 1.8 up/down | CT |
| 43 | Eingang B (innerhalb Grenzwerte/an Grenzwert 1) | Szene aufrufen | 1 Byte | 16.0 Character String (ASCII) | CT |
| 43 | Eingang B (innerhalb Grenzwerte/an Grenzwert 1) | Sequenz Start/Stopp | 1 Bit | 1.10 start/stop | CT |
| 43 | Eingang B (innerhalb Grenzwerte/an Grenzwert 1) | Wert 0…100% | 1 Byte | 5.1 percentage (0..100%) | CT |
| 43 | Eingang B (innerhalb Grenzwerte/an Grenzwert 1) | Wert | 1 Byte | 16.0 Character String (ASCII) | CT |
| 43 | Eingang B (innerhalb Grenzwerte/an Grenzwert 1) | Wert | 2 Bytes | 7.1 pulses | CT |
| 43 | Eingang B (innerhalb Grenzwerte/an Grenzwert 1) | String (14 Bytes) | 14 Bytes | 16.0 Character String (ASCII) | CT |
| 43 | Logik Block B | Eingang 3 | 1 Bit | 1.1 switch | CWU |
| 43 | Logik Block B | Eingang 3 | 1 Byte | 16.0 Character String (ASCII) | CWU |
| 43 | Logik Block B | Eingang 3 | 2 Bytes | 7.1 pulses | CWU |
| 43 | Logik Block B | Eingang 3 | 2 Bytes | DPT.9 | CWU |
| 43 | Logik Block B | Eingang 3 | 4 Bytes | 12.1 counter pulses (unsigned) | CWU |
| 43 | Ausgang B | Status EIN/AUS | 1 Bit | 1.1 switch | CRT |
| 44 | Eingang B | Alarm Zähler | 1 Bit | 16.0 Character String (ASCII) | CT |
| 44 | Eingang B (geschlossen) | EIN/AUS | 1 Bit | 1.1 switch | CT |
| 44 | Eingang B (geschlossen) | Jalousie | 1 Bit | 1.8 up/down | CT |
| 44 | Eingang B (geschlossen) | Szene aufrufen | 1 Byte | 16.0 Character String (ASCII) | CT |
| 44 | Eingang B (geschlossen) | Sequenz Start/Stopp | 1 Bit | 1.10 start/stop | CT |
| 44 | Eingang B (geschlossen) | Wert 0…100% | 1 Byte | 5.1 percentage (0..100%) | CT |
| 44 | Eingang B (geschlossen) | Wert | 1 Byte | 16.0 Character String (ASCII) | CT |
| 44 | Eingang B (geschlossen) | Wert | 2 Bytes | 7.1 pulses | CT |
| 44 | Eingang B (geschlossen) | String (14 Bytes) | 14 Bytes | 16.0 Character String (ASCII) | CT |
| 44 | Eingang B (kurzer Tastendruck) | EIN/AUS | 1 Bit | 1.1 switch | CT |
| 44 | Eingang B (kurzer Tastendruck) | Jalousie | 1 Bit | 1.8 up/down | CT |
| 44 | Eingang B (kurzer Tastendruck) | Szene aufrufen | 1 Byte | 16.0 Character String (ASCII) | CT |
| 44 | Eingang B (kurzer Tastendruck) | Sequenz Start/Stopp | 1 Bit | 1.10 start/stop | CT |
| 44 | Eingang B (kurzer Tastendruck) | Wert 0…100% | 1 Byte | 5.1 percentage (0..100%) | CT |
| 44 | Eingang B (kurzer Tastendruck) | Wert | 1 Byte | 16.0 Character String (ASCII) | CT |
| 44 | Eingang B (kurzer Tastendruck) | Wert | 2 Bytes | 7.1 pulses | CT |
| 44 | Eingang B (kurzer Tastendruck) | String (14 Bytes) | 14 Bytes | 16.0 Character String (ASCII) | CT |
| 44 | Eingang B | Zwangsführung | 1 Bit | 1.1 switch | CWU |
| 44 | Eingang B | Alarm | 1 Bit | 1.1 switch | CWU |
| 44 | Eingang B | Auf/Ab | 1 Bit | 1.1 switch | CWU |
| 44 | Eingang B | Szene aufrufen | 1 Bit | 1.1 switch | CWU |
| 44 | Eingang B | Sequenz | 1 Bit | 1.1 switch | CWU |
| 44 | Eingang B | Wert (0…100%) | 1 Bit | 1.1 switch | CWU |
| 44 | Eingang B | Wert | 1 Bit | 1.1 switch | CWU |
| 44 | Eingang B | String (14 Bytes) | 1 Bit | 1.1 switch | CWU |
| 44 | Eingang B | Grenzwert 2 | 2 Bytes | 9.1 temperature (°C) | CWU |
| 44 | Eingang B (innerhalb Grenzwerte/an Grenzwert 1) | EIN/AUS | 1 Bit | 1.1 switch | CT |
| 44 | Eingang B (innerhalb Grenzwerte/an Grenzwert 1) | Alarm | 1 Bit | 16.0 Character String (ASCII) | CT |
| 44 | Eingang B (innerhalb Grenzwerte/an Grenzwert 1) | Jalousie | 1 Bit | 1.8 up/down | CT |
| 44 | Eingang B (innerhalb Grenzwerte/an Grenzwert 1) | Szene aufrufen | 1 Byte | 16.0 Character String (ASCII) | CT |
| 44 | Eingang B (innerhalb Grenzwerte/an Grenzwert 1) | Sequenz Start/Stopp | 1 Bit | 1.10 start/stop | CT |
| 44 | Eingang B (innerhalb Grenzwerte/an Grenzwert 1) | Wert 0…100% | 1 Byte | 5.1 percentage (0..100%) | CT |
| 44 | Eingang B (innerhalb Grenzwerte/an Grenzwert 1) | Wert | 1 Byte | 16.0 Character String (ASCII) | CT |
| 44 | Eingang B (innerhalb Grenzwerte/an Grenzwert 1) | Wert | 2 Bytes | 7.1 pulses | CT |
| 44 | Eingang B (innerhalb Grenzwerte/an Grenzwert 1) | String (14 Bytes) | 14 Bytes | 16.0 Character String (ASCII) | CT |
| 44 | Logik Block B | Eingang 4 | 1 Bit | 1.1 switch | CWU |
| 44 | Logik Block B | Eingang 4 | 1 Byte | 16.0 Character String (ASCII) | CWU |
| 44 | Logik Block B | Eingang 4 | 2 Bytes | 7.1 pulses | CWU |
| 44 | Logik Block B | Eingang 4 | 2 Bytes | DPT.9 | CWU |
| 44 | Logik Block B | Eingang 4 | 4 Bytes | 12.1 counter pulses (unsigned) | CWU |
| 44 | Ausgang B | Status 0…100% | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 45 | Eingang B (geschlossen) | EIN/AUS | 1 Bit | 1.1 switch | CT |
| 45 | Eingang B (geschlossen) | Jalousie | 1 Bit | 1.8 up/down | CT |
| 45 | Eingang B (geschlossen) | Szene aufrufen | 1 Byte | 16.0 Character String (ASCII) | CT |
| 45 | Eingang B (geschlossen) | Sequenz Start/Stopp | 1 Bit | 1.10 start/stop | CT |
| 45 | Eingang B (geschlossen) | Wert 0…100% | 1 Byte | 5.1 percentage (0..100%) | CT |
| 45 | Eingang B (geschlossen) | Wert | 1 Byte | 16.0 Character String (ASCII) | CT |
| 45 | Eingang B (geschlossen) | Wert | 2 Bytes | 7.1 pulses | CT |
| 45 | Eingang B (geschlossen) | String (14 Bytes) | 14 Bytes | 16.0 Character String (ASCII) | CT |
| 45 | Eingang B (kurzer Tastendruck) | EIN/AUS | 1 Bit | 1.1 switch | CT |
| 45 | Eingang B (kurzer Tastendruck) | Jalousie | 1 Bit | 1.8 up/down | CT |
First 1000 of 3167 group objects shown. Download the .knxprod for the full list.
Parameters (571)
| Parameter | Type | Default |
|---|---|---|
| Betriebsart | list | Sensormodul |
| Verzögerung Start Applikation nach Busspannungswiederkehr (2…255 Sek.) | unsignedInt 2…255 | 2 |
| NULL | list | FALSE |
| Heartbeat-Telegramm (1...65535 Sek., 0 = keine Übertragung) | unsignedInt 0…65535 | 0 |
| ->Temperaturauflösung | list | 1°C |
| Kanal A: LED-Ausgang | list | Nein |
| Kanal B: LED-Ausgang | list | Nein |
| Kanal C: LED-Ausgang | list | Nein |
| Kanal D: LED-Ausgang | list | Nein |
| Logik Block A: LED-Ausgabe | list | Nein |
| Logik Block B: LED-Ausgabe | list | Nein |
| Logik Block C: LED-Ausgabe | list | Nein |
| Logik Block D: LED-Ausgabe | list | Nein |
| Sequenz 1 | list | Nicht aktiv |
| Sequenz 2 | list | Nicht aktiv |
| Sequenz 3 | list | Nicht aktiv |
| Sequenz 4 | list | Nicht aktiv |
| Sequenz 5 | list | Nicht aktiv |
| Start/Stopp von Sequenz 1 | list | Start bei EIN, Stopp bei AUS |
| Abfolge | list | Vorwärts |
| Wiederholung | list | Zyklisch |
| Laufzeit (0…255 Std., 0 Std. und 0 Min. = nicht begrenzt) | unsignedInt 0…255 | 0 |
| Laufzeit (0…59 Min., 0 Std. und 0 Min. = nicht begrenzt) | unsignedInt 0…59 | 0 |
| Benutzte Szene beim Beenden der Sequenz | list | Nicht aktiv |
| >>Benutzte Szene bei Schritt 1 | list | Nicht aktiv |
| Zeit bis Schritt 1 (0....65535s) | unsignedInt 0…65535 | 5 |
| Zeit bis Schritt 1 (0....999ms) | unsignedInt 0…999 | 0 |
| >>Benutzte Szene bei Schritt 2 | list | Nicht aktiv |
| Zeit bis Schritt 2 (0...65535s) | unsignedInt 0…65535 | 5 |
| Zeit bis Schritt 2 (0...999ms) | unsignedInt 0…999 | 0 |
| >>Benutzte Szene bei Schritt 3 | list | Nicht aktiv |
| Zeit bis Schritt 3 (0...65535s) | unsignedInt 0…65535 | 5 |
| Zeit bis Schritt 3 (0...999ms) | unsignedInt 0…999 | 0 |
| >>Benutzte Szene bei Schritt 4 | list | Nicht aktiv |
| Zeit bis Schritt 4 (0...65535s) | unsignedInt 0…65535 | 5 |
| Zeit bis Schritt 4 (0...999ms) | unsignedInt 0…999 | 0 |
| >>Benutzte Szene bei Schritt 5 | list | Nicht aktiv |
| Zeit bis Schritt 5 (0...65535s) | unsignedInt 0…65535 | 5 |
| Zeit bis Schritt 5 (0...999ms) | unsignedInt 0…999 | 0 |
| >>Benutzte Szene bei Schritt 6 | list | Nicht aktiv |
| Zeit bis Schritt 6 (0...65535s) | unsignedInt 0…65535 | 5 |
| Zeit bis Schritt 6 (0...999ms) | unsignedInt 0…999 | 0 |
| >>Benutzte Szene bei Schritt 7 | list | Nicht aktiv |
| Zeit bis Schritt 7 (0...65535s) | unsignedInt 0…65535 | 5 |
| Zeit bis Schritt 7 (0...999ms) | unsignedInt 0…999 | 0 |
| >>Benutzte Szene bei Schritt 8 | list | Nicht aktiv |
| Zeit bis Schritt 8 (0...65535s) | unsignedInt 0…65535 | 5 |
| Zeit bis Schritt 8 (0...999ms) | unsignedInt 0…999 | 0 |
| >>Benutzte Szene bei Schritt 9 | list | Nicht aktiv |
| Zeit bis Schritt 9 (0...65535s) | unsignedInt 0…65535 | 5 |
| Zeit bis Schritt 9 (0...999ms) | unsignedInt 0…999 | 0 |
| >>Benutzte Szene bei Schritt 10 | list | Nicht aktiv |
| Zeit bis Schritt 10 (0....65535s) | unsignedInt 0…65535 | 5 |
| Zeit bis Schritt 10 (0....999ms) | unsignedInt 0…999 | 0 |
| >>Benutzte Szene bei Schritt 11 | list | Nicht aktiv |
| Zeit bis Schritt 11 (0....65535s) | unsignedInt 0…65535 | 5 |
| Zeit bis Schritt 11 (0....999ms) | unsignedInt 0…999 | 0 |
| >>Benutzte Szene bei Schritt 12 | list | Nicht aktiv |
| Zeit bis Schritt 12 (0....65535s) | unsignedInt 0…65535 | 5 |
| Zeit bis Schritt 12 (0....999ms) | unsignedInt 0…999 | 0 |
| >>Benutzte Szene bei Schritt 13 | list | Nicht aktiv |
| Zeit bis Schritt 13 (0...65535s) | unsignedInt 0…65535 | 5 |
| Zeit bis Schritt 13 (0...999ms) | unsignedInt 0…999 | 0 |
| >>Benutzte Szene bei Schritt 14 | list | Nicht aktiv |
| Zeit bis Schritt 14 (0...65535s) | unsignedInt 0…65535 | 5 |
| Zeit bis Schritt 14 (0...999ms) | unsignedInt 0…999 | 0 |
| >>Benutzte Szene bei Schritt 15 | list | Nicht aktiv |
| Zeit bis Schritt 15 (0...65535s) | unsignedInt 0…65535 | 5 |
| Zeit bis Schritt 15 (0...999ms) | unsignedInt 0…999 | 0 |
| >>Benutzte Szene bei Schritt 16 | list | Nicht aktiv |
| Zeit bis Schritt 16 (0...65535s) | unsignedInt 0…65535 | 5 |
| Zeit bis Schritt 16 (0...999ms) | unsignedInt 0…999 | 0 |
| >>Benutzte Szene bei Schritt 17 | list | Nicht aktiv |
| Zeit bis Schritt 17 (0...65535s) | unsignedInt 0…65535 | 5 |
| Zeit bis Schritt 17 (0...999ms) | unsignedInt 0…999 | 0 |
| >>Benutzte Szene bei Schritt 18 | list | Nicht aktiv |
| Zeit bis Schritt 18 (0...65535s) | unsignedInt 0…65535 | 5 |
| Zeit bis Schritt 18 (0...999ms) | unsignedInt 0…999 | 0 |
| >>Benutzte Szene bei Schritt 19 | list | Nicht aktiv |
| Zeit bis Schritt 19 (0...65535s) | unsignedInt 0…65535 | 5 |
| Zeit bis Schritt 12 (0...999ms) | unsignedInt 0…999 | 0 |
| >>Benutzte Szene bei Schritt 20 | list | Nicht aktiv |
| Zeit bis Schritt 20 (0...65535s) | unsignedInt 0…65535 | 5 |
| Zeit bis Schritt 20 (0...999ms) | unsignedInt 0…999 | 0 |
| >>Benutzte Szene bei Schritt 21 | list | Nicht aktiv |
| Zeit bis Schritt 21 (0...65535s) | unsignedInt 0…65535 | 5 |
| Zeit bis Schritt 21 (0...999ms) | unsignedInt 0…999 | 0 |
| >>Benutzte Szene bei Schritt 22 | list | Nicht aktiv |
| Zeit bis Schritt 22 (0...65535s) | unsignedInt 0…65535 | 5 |
| Zeit bis Schritt 22 (0...999ms) | unsignedInt 0…999 | 0 |
| >>Benutzte Szene bei Schritt 23 | list | Nicht aktiv |
| Zeit bis Schritt 23 (0...65535s) | unsignedInt 0…65535 | 5 |
| Zeit bis Schritt 23 (0...999ms) | unsignedInt 0…999 | 0 |
| >>Benutzte Szene bei Schritt 24 | list | Nicht aktiv |
| Zeit bis Schritt 24 (0...65535s) | unsignedInt 0…65535 | 5 |
| Zeit bis Schritt 24 (0...999ms) | unsignedInt 0…999 | 0 |
| Start/Stopp von Sequenz 2 | list | Start bei EIN, Stopp bei AUS |
| Start/Stopp von Sequenz 3 | list | Start bei EIN, Stopp bei AUS |
| Start/Stopp von Sequenz 4 | list | Start bei EIN, Stopp bei AUS |
| Start/Stopp von Sequenz 5 | list | Start bei EIN, Stopp bei AUS |
| Betriebsart Eingang A | list | Nicht belegt |
| Offset (-5…5°C) | list | 0°C |
| Temperaturausgabe über KNX | list | Nein |
| Sperrobjekt | list | Nicht aktiv |
| Funktion ==> | list | Schalten |
| Eingangsbelegung | list | Mechanischer Schalter |
| Reaktion beim Schließen des Kontakts | list | EIN |
| Zustand des Kontakts ohne Betätigung | list | Geöffnet |
| Reaktion beim Öffnen des Kontakts | list | AUS |
| Reaktion bei kurzem Tastendruck | list | Toggeln |
| Einschaltverzögerung (0…255 Sek.) | unsignedInt 0…255 | 0 |
| Reaktion bei langem Tastendruck | list | Nicht aktiv |
| Ausschaltverzögerung (0…255 Sek.) | unsignedInt 0…255 | 0 |
| Langer Tastendruck wird erkannt nach | list | 1 Sek. |
| Nach Empfang über Bus wird nächstes Toggeln invertiert | list | Nein |
| Verzögerungszeit bei Reaktion kurzer Tastendruck (0…255 Sek.) | unsignedInt 0…255 | 0 |
| Zyklisches Senden | list | Nein |
| Verzögerungszeit bei Reaktion langer Tastendruck (0…255 Sek.) | unsignedInt 0…255 | 0 |
| -Zeitabstand für zyklisches Senden (1…255 Sek.) | unsignedInt 1…255 | 1 |
| Nach Empfang über Bus wird nächstes Toggeln bei kurzem Tastendruck invertiert | list | Nein |
| -Anzahl der zyklischen Wiederholungen (1...255, 0 = keine Begrenzung) | unsignedInt 0…255 | 0 |
| Nach Empfang über Bus wird nächstes Toggeln bei langem Tastendruck invertiert | list | Nein |
| Min. Nachlaufzeit nach Schließen des Kontakts (Basis) | list | 10 ms. |
| -Faktor (1…255)->Zeitabstand = Basis*Faktor | unsignedInt 1…255 | 1 |
| Reaktion beim Schließen des Kontakts | list | Heller/Dunkler abwechselnd |
| Aktueller Zustand wird gesendet bei Busspannungswiederkehr | list | Ja |
| Reaktion beim Öffnen des Kontakts | list | Stopptelegramm |
| Dimmschritt | list | Schritt 1 (100%) |
| Reaktion bei langem Tastendruck | list | Heller/Dunkler abwechselnd |
| Rel.Dimmen wird zyklisch wiederholt (nur Schrittbefehle) | list | Nicht aktiv |
| -Zeitabstand für zyklisches Wiederholen | list | 0,4 Sek. |
| -Anzahl der Wiederholung (1…255, 0 = nicht begrenzt) | unsignedInt 0…255 | 0 |
| Aktueller Zustand wird gesendet bei Busspannungswiederkehr | list | Nein |
| Zyklische Wiederholung von Dimmen | list | Nicht aktiv |
| -Zeitabstand für zyklisches Wiederholen | list | 0,3 Sek. |
| Reaktion beim Schließen des Kontakts | list | Ab |
| Reaktion beim Öffnen des Kontakts | list | Nicht aktiv |
| Reaktion bei kurzem Tastendruck | list | Schritt auf/Stopp |
| Sendeverzögerung für Schrittbefehle (0…255 Sek.) | unsignedInt 0…255 | 0 |
| Reaktion bei langem Tastendruck | list | Auf/ab abwechselnd |
| Sendeverzögerung für Fahrbefehle (0…255 Sek.) | unsignedInt 0…255 | 0 |
| Zyklische Wiederholung von Stopp/Schritt | list | Nicht aktiv |
| -Zeitabstand | list | 0,2 Sek. |
| -Anzahl der Wiederholungen (1…255, 0 = nicht begrenzt) | unsignedInt 0…255 | 0 |
| Automatisches Senden von Stopp nach Schließen des Kontakts | list | Nicht aktiv |
| -Sendeverzögerung des automatischen Stopp-Telegramms (Basis) | list | 1 Sekunde |
| -Faktor (1…255)->Zeitabstand = Basis*Faktor | unsignedInt 1…255 | 10 |
| Verhalten des Schalters | list | Umschalten bei Aktivierung |
| Gesendete Szene beim Schließen des Kontakts | list | Szene 01 |
| Gesendete Szene beim Öffnen des Kontakts | list | Szene 02 |
| Gesendete Szene bei kurzem Tastendruck | list | Szene 01 |
| Sendeverzögerung beim Schließen des Kontakts (0…255 Sek.) | unsignedInt 0…255 | 0 |
| Reaktion bei langem Tastendruck | list | Dimmen |
| Sendeverzögerung beim Öffnen des Kontakts (0…255 Sek.) | unsignedInt 0…255 | 0 |
| -Dimmrichtung | list | Heller |
| Langer Tastendruck wird erkannt nach | list | 0,2 Sek. |
| 2. Szene bei kurzem Tastendruck | list | Nein |
| -2. Szene | list | Szene 02 |
| Sendeverzögerung (0…255 Sek.) | unsignedInt 0…255 | 0 |
| Reaktion beim Schließen des Kontakts | list | Start (EIN) |
| Reaktion beim Öffnen des Kontakts | list | Stopp (AUS) |
| Reaktion bei kurzem Tastendruck | list | Stopp (AUS) |
| Langer Tastendruck wird erkannt nach | list | 0,4 Sek. |
| Sendeverzögerung bei kurzem Tastendruck (0…255 Sek.) | unsignedInt 0…255 | 0 |
| Sendeverzögerung bei langem Tastendruck (0…255 Sek.) | unsignedInt 0…255 | 0 |
| Gesendeter Wert beim Schließen des Kontakts | list | 100% (255) |
| Gesendeter Wert beim Öffnen des Kontakts | list | 0% (0) |
| Reaktion bei kurzem Tastendruck | list | 0% (0) |
| Reaktion bei langem Tastendruck | list | 100% (255) |
| 2. Wert bei kurzem Tastendruck | list | Nein |
| -2. Wert | list | 0% (0) |
| 2. Wert bei langem Tastendruck | list | Nein |
| Typ des Ausgabewerts beim Schließen des Kontakts | list | 1 Byte (0…255) |
| -Wert (0…255) | unsignedInt 0…255 | 0 |
| Reaktion bei kurzem Tastendruck | list | 1 Byte (0…255) |
| -Wert (0…65535) | unsignedInt 0…65535 | 0 |
| Typ des Ausgabewerts beim Öffnen des Kontakts | list | 1 Byte (0…255) |
| Reaktion bei langem Tastendruck | list | 1 Byte (0…255) |
| 2. Wert bei kurzem Tastendruck | list | Ja |
| -2. Wert (0…255) | unsignedInt 0…255 | 0 |
| -2. Wert (0…65535) | unsignedInt 0…65535 | 0 |
| Gesendeter String (max. 14 Bytes) beim Schließen des Kontakts | text | Hello world! |
| Gesendeter String (max. 14 Bytes) beim Öffnen des Kontakts | text | Hello world! |
| Gesendeter String (max. 14 Bytes) bei kurzem Tastendruck | text | Hello world! |
| Gesendeter String (max. 14 Bytes) bei langem Tastendruck | text | Hello world! |
| Gesendeter Wert beim Schließen des Kontakts | list | 2-Bit Zwangsführung |
| -Gesendeter Zustand (EIN/AUS) | list | Zwangsführung EIN |
| Wert bei kurzem Tastendruck | list | 2-Bit Zwangsführung |
| -Gesendeter Wert (0…255) | unsignedInt 0…255 | 0 |
| -Gesendeter Wert (-32768...32767) | signedInt -32768…32767 | 0 |
| -Gesendeter Wert (0...65535) | unsignedInt 0…65535 | 0 |
| -Gesendeter Wert | list | 0 |
| -Gesendeter Wert (0...2147483647) | unsignedInt 0…2147483647 | 0 |
| Gesendeter Wert beim Öffnen des Kontakts | list | 2-Bit Zwangsführung |
| -Gesendeter Zustand (EIN/AUS) | list | Zwangsführung AUS |
| Wert bei langem Tastendruck | list | 2-Bit Zwangsführung |
| Zählen der Impulse | list | Beim Schließen des Kontakts (fallende Flanke) |
| Schrittweite des Zählers bei einem Impuls (1…65535) | unsignedInt 1…65535 | 1 |
| Größe der Zählervariablen | list | 1 Byte (0…255) |
| Zählerende bei (0…255) | unsignedInt 0…255 | 0 |
| Zählerende bei (0…65535) | unsignedInt 0…65535 | 0 |
| Zählerende bei (0...2147483647) | unsignedInt 0…2147483647 | 100000 |
| Vorgabe des Zählerendes über Telegramm | list | Nicht aktiv |
| Vorgabe des aktuellen Zählerwerts über Telegramm | list | Nicht aktiv |
| Senden des Zählerwerts | list | Jeder neue Zählerwert wird gesendet |
| Zyklisches Senden (Basis) | list | 1 Sekunde |
| Verhalten bei Überlauf | list | Zurücksetzen |
| Min. Nachlaufzeit nach Schließen des Kontakts (Basis) | list | 100 ms. |
| Reaktion beim Schließen des Kontakts | text | On closing-> |
| Funktion 1 (beim Schließen des Kontakts) | list | Nicht aktiv |
| Reaktion bei kurzem Tastendruck | text | On short-> |
| -Schalttelegramm | list | EIN |
| Funktion 1 (bei kurzem Tastendruck) | list | Nicht aktiv |
| -Fahrtrichtung | list | Auf |
| -Szene | list | Szene 01 |
| -2. Szene | list | Nein |
| -Sequenz | list | Start |
| -Wert | list | 100% (255) |
| -2. Wert | list | Nein |
| -Typ des Ausgabeobjekts | list | 1 Byte (0…255) |
| -Wert (0…255) | unsignedInt 0…255 | 255 |
| -Wert (0…65535) | unsignedInt 0…65535 | 1000 |
| -String (14 Bytes) | text | Hello world! |
| Funktion 2 (beim Schließen des Kontakts) | list | Nicht aktiv |
| Funktion 2 (bei kurzem Tastendruck) | list | Nicht aktiv |
| Funktion 3 (beim Schließen des Kontakts) | list | Nicht aktiv |
| Funktion 3 (bei kurzem Tastendruck) | list | Nicht aktiv |
| Funktion 4 (beim Schließen des Kontakts) | list | Nicht aktiv |
| Funktion 4 (bei kurzem Tastendruck) | list | Nicht aktiv |
| Funktion 5 (beim Schließen des Kontakts) | list | Nicht aktiv |
| Funktion 5 (bei kurzem Tastendruck) | list | Nicht aktiv |
| Funktion 6 (beim Schließen des Kontakts) | list | Nicht aktiv |
| Funktion 6 (bei kurzem Tastendruck) | list | Nicht aktiv |
| Funktion 7 (beim Schließen des Kontakts) | list | Nicht aktiv |
| Funktion 7 (bei kurzem Tastendruck) | list | Nicht aktiv |
| Funktion 8 (beim Schließen des Kontakts) | list | Nicht aktiv |
| Funktion 8 (bei kurzem Tastendruck) | list | Nicht aktiv |
| Funktion 9 (beim Schließen des Kontakts) | list | Nicht aktiv |
| Funktion 9 (bei kurzem Tastendruck) | list | Nicht aktiv |
| Funktion 10 (beim Schließen des Kontakts) | list | Nicht aktiv |
| Funktion 10 (bei kurzem Tastendruck) | list | Nicht aktiv |
| Reaktion beim Öffnen des Kontakts | text | On opening-> |
| Funktion 1 (beim Öffnen des Kontakts) | list | Nicht aktiv |
| Reaktion bei langem Tastendruck | text | On long-> |
| Funktion 1 (bei langem Tastendruck) | list | Nicht aktiv |
| Funktion 2 (beim Öffnen des Kontakts) | list | Nicht aktiv |
| Funktion 2 (bei langem Tastendruck) | list | Nicht aktiv |
| Funktion 3 (beim Öffnen des Kontakts) | list | Nicht aktiv |
| Funktion 3 (bei langem Tastendruck) | list | Nicht aktiv |
| Funktion 4 (beim Öffnen des Kontakts) | list | Nicht aktiv |
| Funktion 4 (bei langem Tastendruck) | list | Nicht aktiv |
| Funktion 5 (beim Öffnen des Kontakts) | list | Nicht aktiv |
| Funktion 5 (bei langem Tastendruck) | list | Nicht aktiv |
| Funktion 6 (beim Öffnen des Kontakts) | list | Nicht aktiv |
| Funktion 6 (bei langem Tastendruck) | list | Nicht aktiv |
| Funktion 7 (beim Öffnen des Kontakts) | list | Nicht aktiv |
| Funktion 7 (bei langem Tastendruck) | list | Nicht aktiv |
| Funktion 8 (beim Öffnen des Kontakts) | list | Nicht aktiv |
| Funktion 8 (bei langem Tastendruck) | list | Nicht aktiv |
| Funktion 9 (beim Öffnen des Kontakts) | list | Nicht aktiv |
| Funktion 9 (bei langem Tastendruck) | list | Nicht aktiv |
| Funktion 10 (beim Öffnen des Kontakts) | list | Nicht aktiv |
| Funktion 10 (bei langem Tastendruck) | list | Nicht aktiv |
| Funktion ==> | list | Nicht aktiv |
| ->Grenzwert 1 (-30°C...50°C) | signedInt -30…50 | 20 |
| ->Grenzwert 2 (-30°C...50°C) | signedInt -30…50 | 30 |
| --Vorgabe der Grenzwerte über Telegramm | list | Ja |
| Betriebsart der Temperaturüberwachung | list | Überwachung des Bereichs |
| ->Ausgabe (innerhalb Grenzwerte) | list | EIN |
| ->Ausgabe (außerhalb Grenzwerte) | list | AUS |
| ->Ausgabe bei Grenzwert 1 | list | EIN |
| ->Ausgabe bei Grenzwert 2 | list | AUS |
| Minimales Auswerteintervall der Temperaturüberwachung (Basis) | list | 1 Sekunde |
| Zwangsführung (EIN = Zwangsführung, AUS = Temperaturüberwachung) | list | Nein |
| -Ausgabe bei Zwangsführung | list | EIN |
| ->Alarmausgabe (innerhalb Grenzwerte) | list | Alarm |
| ->Alarmausgabe (außerhalb Grenzwerte) | list | Kein Alarm |
| ->Alarmausgabe bei Grenzwert 1 | list | Alarm |
| ->Alarmausgabe bei Grenzwert 2 | list | Kein Alarm |
| -Ausgabe bei Zwangsführung | list | Alarm |
| ->Ausgabe (innerhalb Grenzwerte) | list | Auf |
| ->Ausgabe (außerhalb Grenzwerte) | list | Ab |
| ->Ausgabe bei Grenzwert 1 | list | Auf |
| ->Ausgabe bei Grenzwert 2 | list | Ab |
| -Ausgabe bei Zwangsführung | list | Auf |
| ->Ausgabe Szene (innerhalb Grenzwerte) | list | Szene 01 |
| ->Ausgabe Szene (außerhalb Grenzwerte) | list | Szene 02 |
| ->Ausgabe Szene bei Grenzwert 1 | list | Szene 01 |
| ->Ausgabe Szene bei Grenzwert 2 | list | Szene 02 |
| -Ausgabe bei Zwangsführung | list | Szene 03 |
| ->Ausgabe (innerhalb Grenzwerte) | list | Start |
| ->Ausgabe (außerhalb Grenzwerte) | list | Stopp |
| ->Ausgabe bei Grenzwert 1 | list | Start |
| ->Ausgabe bei Grenzwert 2 | list | Stopp |
| -Ausgabe bei Zwangsführung | list | Start |
| ->Ausgabe (innerhalb Grenzwerte) | list | 100% (255) |
| ->Ausgabe (außerhalb Grenzwerte) | list | 0% (0) |
| ->Ausgabe bei Grenzwert 1 | list | 100% (255) |
| ->Ausgabe bei Grenzwert 2 | list | 0% (0) |
| -Ausgabe bei Zwangsführung | list | 100% (255) |
| Typ des Grenzwerts | list | 1 Byte (0…255) |
| ->Ausgabe bei Grenzwert 1 | list | Ja |
| ->Ausgabe bei Grenzwert 2 | list | Nein |
| ->Ausgabe bei Grenzwert 2 | list | Ja |
| ->Ausgabe (innerhalb Grenzwerte) | list | Ja |
| ->Ausgabe (außerhalb Grenzwerte) | list | Nein |
| ->Ausgabe (außerhalb Grenzwerte) | list | Ja |
| -Faktor (1…255)->Zeitabstand = Basis*Faktor | unsignedInt 1…255 | 5 |
| -Ausgabewert bei Zwangsführung (0...255) | unsignedInt 0…255 | 0 |
| -Ausgabewert bei Zwangsführung (0...65535) | unsignedInt 0…65535 | 0 |
| ->Ausgabe (innerhalb Grenzwerte) | text | Hello world! |
| ->Ausgabe (außerhalb Grenzwerte) | text | Hello world! |
| ->Ausgabe bei Grenzwert 1 | text | Hello world! |
| ->Ausgabe bei Grenzwert 2 | text | Hello world! |
| -Ausgabe bei Zwangsführung | text | Hello world! |
| ->Ausgabe (innerhalb Grenzwerte/bei Grenzwert 1) | list | 2-Bit Zwangsführung |
| ->Ausgabe (außerhalb Grenzwerte/bei Grenzwert 2) | list | 2-Bit Zwangsführung |
| Kombinierte Ausgabe | text | In range-> |
| Kombinierte Ausgabe bei | text | In range-> |
| Funktion 1 (innerhalb Grenzwerte/bei Grenzwert 1) | list | Nicht aktiv |
| -Alarm | list | Alarm |
| Funktion 2 (innerhalb Grenzwerte/bei Grenzwert 1) | list | Nicht aktiv |
| Funktion 3 (innerhalb Grenzwerte/bei Grenzwert 1) | list | Nicht aktiv |
| Funktion 4 (innerhalb Grenzwerte/bei Grenzwert 1) | list | Nicht aktiv |
| Funktion 5 (innerhalb Grenzwerte/bei Grenzwert 1) | list | Nicht aktiv |
| Funktion 6 (innerhalb Grenzwerte/bei Grenzwert 1) | list | Nicht aktiv |
| Funktion 7 (innerhalb Grenzwerte/bei Grenzwert 1) | list | Nicht aktiv |
| Funktion 8 (innerhalb Grenzwerte/bei Grenzwert 1) | list | Nicht aktiv |
| Funktion 9 (innerhalb Grenzwerte/bei Grenzwert 1) | list | Nicht aktiv |
| Funktion 10 (innerhalb Grenzwerte/bei Grenzwert 1) | list | Nicht aktiv |
| Kombinierte Ausgabe | text | Out range-> |
| Kombinierte Ausgabe bei | text | Out range-> |
| Funktion 1 (außerhalb Grenzwerte/bei Grenzwert 2) | list | Nicht aktiv |
| -Schalttelegramm | list | AUS |
| -Alarm | list | Kein Alarm |
| -Fahrtrichtung | list | Ab |
| -Szene | list | Szene 02 |
| -Sequenz | list | Stopp |
| -Wert | list | 0% (0) |
| Funktion 2 (außerhalb Grenzwerte/bei Grenzwert 2) | list | Nicht aktiv |
| Funktion 3 (außerhalb Grenzwerte/bei Grenzwert 2) | list | Nicht aktiv |
| Funktion 4 (außerhalb Grenzwerte/bei Grenzwert 2) | list | Nicht aktiv |
| Funktion 5 (außerhalb Grenzwerte/bei Grenzwert 2) | list | Nicht aktiv |
| Funktion 6 (außerhalb Grenzwerte/bei Grenzwert 2) | list | Nicht aktiv |
| Funktion 7 (außerhalb Grenzwerte/bei Grenzwert 2) | list | Nicht aktiv |
| Funktion 8 (außerhalb Grenzwerte/bei Grenzwert 2) | list | Nicht aktiv |
| Funktion 9 (außerhalb Grenzwerte/bei Grenzwert 2) | list | Nicht aktiv |
| Funktion 10 (außerhalb Grenzwerte/bei Grenzwert 2) | list | Nicht aktiv |
| Temperaturausgabe | list | Bei Änderung |
| Minimaler Zeitabstand der Temperaturausgabe (Basis) | list | 1 Sekunde |
| Zyklische Temperaturausgabe (Basis) | list | 1 Sekunde |
| Betriebsart Eingang B | list | Nicht belegt |
| Betriebsart Eingang C | list | Nicht belegt |
| Betriebsart Eingang D | list | Nicht belegt |
| Funktion Ausgang A | list | Statusanzeige über LED |
| Betriebsart | list | Statusanzeige |
| Maximale Betriebsspannung der LED (bei 100% Helligkeit) | list | 2V |
| Voreingestellte Helligkeit der LED beim Einschalten | list | 100% (255) |
| LED-Ansteuerung durch | list | Interner Status |
| Helligkeit der aktivierten LED einstellbar über KNX | list | Nein |
| -Statusobjekt LED (1 Bit) | list | Nicht aktiv |
| -Statusobjekt LED (1 Byte) | list | Nicht aktiv |
| LED wird aktiviert durch | list | Aktiviert wenn Wert >=1, sonst deaktiviert |
| LED-Helligkeit automatisch vermindern nach eingestellter Zeit | list | Nein |
| -LED-Helligkeit während Verminderung | list | 1% |
| -Zeitbasis für Verminderung | list | 1 Sekunde |
| Zustand der LED nach Busspannungswiederkehr | list | Keine Änderung |
| Blinken wird aktiviert durch | list | Blinken wenn Wert >= 1, sonst kein Blinken |
| Dauer der Aktivierung (Basis) | list | 100 ms. |
| Dauer der Deaktivierung (Basis) | list | 100 ms. |
| Zeitbegrenzung von Blinken | list | Nein |
| -Basis | list | 1 Sekunde |
| -Zustand der LED nach Beenden von Blinken | list | AUS |
| Maximum brightness limit(0%..100%) | list | 100% (255) |
| Minimum brightness limit(0%..100%) | list | 0% (0) |
| Enable control via bus | list | Nicht aktiv |
| Funktion Ausgang B | list | Statusanzeige über LED |
| Funktion Ausgang C | list | Statusanzeige über LED |
| Funktion Ausgang D | list | Statusanzeige über LED |
| Logik Block A | list | Nicht aktiv |
| Lokaler Logik-Eingang | list | Nicht aktiv |
| >>Zustand bei geschlossenem Kontakt | list | TRUE |
| >>Zustand bei geöffnetem Kontakt | list | FALSE |
| -- Zustand des Kontakts ohne Betätigung | list | Geöffnet |
| >>Zustand bei kurzem Tastendruck | list | FALSE |
| >>Zustand bei langem Tastendruck | list | FALSE |
| --Langer Tastendruck wird erkannt nach | list | 1 Sek. |
| --Zustand nach Busspannungswiederkehr | list | TRUE |
| Statusobjekt Binäreingang | list | Nein |
| -Übertragungsart | list | Bei Änderung |
| -Minimaler Telegrammabstand (Basis) | list | 1 Sekunde |
| -Zeitabstand | list | 1 Sekunde |
| ->Grenzwert 1 (-30°C...50°C) | signedInt -30…50 | 30 |
| >>Zustand | list | TRUE zwischen den Grenzwerten, sonst FALSE |
| Ausgabeobjekt Temperatur | list | Nein |
| -Temperaturausgabe | list | Bei Änderung |
| -Minimaler Zeitabstand der Temperaturausgabe (Basis) | list | 1 Sekunde |
| -Zyklische Temperaturausgabe (Basis) | list | 1 Sekunde |
| Externer Logik-Eingang <1> | list | Nicht aktiv |
| ->Verarbeitung des Telegramms | list | EIN als TRUE, AUS als FALSE |
| Externer Eingang nach Busspannungswiederkehr | list | TRUE |
| ->Grenzwert (1 Byte, 0…255) | unsignedInt 0…255 | 0 |
| Hysterese bei der Verarbeitung des Eingangs | unsignedInt 0…255 | 1 |
| ->Verarbeitung des Telegramms | list | TRUE wenn Grenzwert überschritten, sonst FALSE |
| ->Grenzwert (2 Bytes, 0…65535) | unsignedInt 0…65535 | 1000 |
| ->Grenzwert (2-Byte-Float, 0…3000) | unsignedInt 0…3000 | 100 |
| ->Grenzwert (4 Bytes, 0…2147483647) | unsignedInt 0…2147483647 | 1000000 |
| Externer Logik-Eingang <2> | list | Nicht aktiv |
| ->Grenzwert (1 Byte, 0…255) | unsignedInt 0…255 | 100 |
| Externer Logik-Eingang <3> | list | Nicht aktiv |
| ->Grenzwert (2 Bytes, 0…65535) | unsignedInt 0…65535 | 0 |
| Externer Logik-Eingang <4> | list | Nicht aktiv |
| Externer Logik-Eingang <5> | list | Nicht aktiv |
| Logische Verknüpfung von Block A | list | UND |
| ->Ausgang Logik A invertieren | list | Nein |
| Sperrobjekt für logische Verknüpfung | list | Nein |
| ->Ausgang von Block A, wenn gesperrt über Bus | list | Zustand beibehalten |
| Ausgangsobjekt 1 (auf KNX) | list | Nicht aktiv |
| Ausgangsobjekt 2 (auf KNX) | list | Nicht aktiv |
| Ausgangsobjekt 3 (auf KNX) | list | Nicht aktiv |
| Ausgangsobjekt 4 (auf KNX) | list | Nicht aktiv |
| Ausgangsobjekt 5 (auf KNX) | list | Nicht aktiv |
| Ausgangsobjekt 6 (auf KNX) | list | Nicht aktiv |
| Ausgangsobjekt 7 (auf KNX) | list | Nicht aktiv |
| Ausgangsobjekt 8 (auf KNX) | list | Nicht aktiv |
| Ausgangsobjekt 9 (auf KNX) | list | Nicht aktiv |
| Ausgangsobjekt 10 (auf KNX) | list | Nicht aktiv |
| Minimaler Zeitabstand der Ausgabe (Basis) | list | 100 ms. |
| Ausgangstelegramm wird zyklisch wiederholt | list | Nein |
| -Wiederholung von | list | Immer |
| -Zeitabstand der zyklischer Wiederholung (2…255 Min.) | unsignedInt 2…255 | 2 |
| Zustand nach Busspannungswiederkehr | list | Gemäß den Eingängen |
| Typ des Ausgabewerts | list | 1 Byte (0…255) |
| Ausgang des logischen Blocks bei TRUE | list | EIN |
| Ausgang des logischen Blocks bei TRUE | list | Alarm |
| Ausgang des logischen Blocks bei TRUE | list | Auf |
| Gesendete Szene bei Busspannungswiederkehr | list | Szene 01 |
| Ausgang des logischen Blocks bei TRUE | list | Start |
| Gesendeter Wert bei Busspannungswiederkehr | list | 100% (255) |
| Gesendeter String bei Busspannungswiederkehr | text | Hello world! |
| Verzögerung für Zustandsänderung auf TRUE (0...65535 Sek.) | unsignedInt 0…65535 | 1000 |
| Ausgang des logischen Blocks bei TRUE | list | Szene 01 |
| Ausgang des logischen Blocks bei TRUE | list | 100% (255) |
| Gesendeter Wert (0…255) bei Busspannungswiederkehr | unsignedInt 0…255 | 255 |
| TRUE wird verarbeitet | list | Ja |
| Ausgang des logischen Blocks bei FALSE | list | AUS |
| Ausgang des logischen Blocks bei FALSE | list | Kein Alarm |
| Ausgang des logischen Blocks bei FALSE | list | Ab |
| Verzögerung für Zustandsänderung auf TRUE (0...65535 Sek.) | unsignedInt 0…65535 | 0 |
| Ausgang des logischen Blocks bei FALSE | list | Stopp |
| TRUE wird verarbeitet | list | Nein |
| Ausgang des logischen Blocks bei TRUE | text | Hello world! |
| Verzögerung für Zustandsänderung auf FALSE (0...65535 Sek.) | unsignedInt 0…65535 | 0 |
| Ausgang des logischen Blocks bei FALSE | list | Szene 02 |
| Ausgang des logischen Blocks bei FALSE | list | 0% (0) |
| Ausgang des logischen Blocks bei TRUE | unsignedInt 0…255 | 0 |
| FALSE wird verarbeitet | list | Nein |
| FALSE wird verarbeitet | list | Ja |
| Ausgang des logischen Blocks bei FALSE | text | Hello world! |
| Ausgang des logischen Blocks bei FALSE | unsignedInt 0…255 | 0 |
| Verzögerung für Zustandsänderung auf FALSE (0...65535 Sek.) | unsignedInt 0…65535 | 1000 |
| Gesendeter Wert (0…65535) bei Busspannungswiederkehr | unsignedInt 0…65535 | 0 |
| Ausgang des logischen Blocks bei TRUE | unsignedInt 0…65535 | 1000 |
| Ausgang des logischen Blocks bei FALSE | unsignedInt 0…65535 | 0 |
| Gesendeter Wert bei Busspannungswiederkehr | list | 0% (0) |
| Gesendeter Wert (0…255) bei Busspannungswiederkehr | unsignedInt 0…255 | 0 |
| Ausgang des logischen Blocks bei TRUE | unsignedInt 0…255 | 255 |
| Gesendeter Wert (0…65535) bei Busspannungswiederkehr | unsignedInt 0…65535 | 1000 |
| Ausgang des logischen Blocks bei TRUE | unsignedInt 0…65535 | 0 |
| Gesendete Szene bei Busspannungswiederkehr | list | Szene 02 |
| Logik Block B | list | Nicht aktiv |
| Logische Verknüpfung von Block B | list | UND |
| ->Ausgang Logik B invertieren | list | Nein |
| ->Ausgang von Block B, wenn gesperrt über Bus | list | Zustand beibehalten |
| Logik Block C | list | Nicht aktiv |
| Logische Verknüpfung von Block C | list | UND |
| ->Ausgang Logik C invertieren | list | Nein |
| ->Ausgang von Block C, wenn gesperrt über Bus | list | Zustand beibehalten |
| Logik Block D | list | Nicht aktiv |
| Auflösung bei der Verarbeitung des Eingangs | unsignedInt 0…255 | 1 |
| Logische Verknüpfung von Block D | list | UND |
| ->Ausgang Logik D invertieren | list | Nein |
| ->Ausgang von Block D, wenn gesperrt über Bus | list | Zustand beibehalten |
| Logik Block E | list | Nicht aktiv |
| ->Verknüpfung von Block A zum nächsten Block | list | Nicht aktiv |
| ->Verknüpfung von Block B zum nächsten Block | list | Nicht aktiv |
| ->Verknüpfung von Block C zum nächsten Block | list | Nicht aktiv |
| Logical relation of Block E | list | UND |
| ->Ausgang Logik E invertieren | list | Nein |
| ->Ausgang von Block E, wenn gesperrt über Bus | list | Zustand beibehalten |
| LED wird aktiviert durch | list | Aktiviert bei EIN oder Wert >= 1, sonst deaktiv. |
| Blinken wird aktiviert durch | list | Blinken bei EIN oder Wert >= 1, sonst kein Blinken |
| Zustand der LED nach Beenden von Blinken | list | AUS |
| Betriebsart Eingang A | list | Nicht aktiv |
| Rückmeldeobjekt (1 Bit) | list | Nicht aktiv |
| Rückmeldeobjekt (1 Byte) | list | Nicht aktiv |
| Ausgang Relaissynchronisation (EIN-Telegramm bei Helligkeit > 0, AUS bei 0) | list | Nein |
| Betriebsstundenüberwachung (0...65535 Std. = 7,4 Jahre) | list | Nicht aktiv |
| Grenzwert Betriebsstunden für Alarm (1…65535 Std.) | unsignedInt 0…65535 | 0 |
| Zeitabstand für Senden von Alarm (1…255 Sek.) | unsignedInt 1…255 | 10 |
First 500 of 571 parameters shown. Download the .knxprod for the full list.
Version history
| Application | App no | Fingerprint | First seen | Size | File |
|---|---|---|---|---|---|
| CU-DIN DRY 4-Z KNX 1.0 latest | $2083 | 9825 | 2026-11-25 | 1.7 MB | Download |
About this file
This is the official ETS product database for the ESYLUX CU-DIN DRY 4-Z KNX (EC10430381), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.
More from ESYLUX
- ESYLUX PD360/8 Basic KNX EB10430442
- CU-DIN R 4-CH 16A KNX EC10430282
- CU-DIN R 8-CH 16A KNX EC10430299
- CU-DIN R 12-CH 16A KNX EC10430305
- CU-DIN DIM 4-CH 1.5A KNX EC10430312
- CU-DIN DIM 6-CH 0…10V KNX EC10430329
- CU-DIN SB 2-CH 10A KNX EC10430343
- CU-DIN SB 4-CH 10A KNX EC10430350
- CU-DIN SB 6-CH 10A KNX EC10430367
- CU-DIN HVAC KNX EC10430503
- CU-DIN IPRT KNX EC10430527
- CU-DIN LC KNX EC10430534