CU-DIN R 8-CH 16A KNX EC10430299
ESYLUX · Order number EC10430299 · Aktoren › Schalten
Download .knxprod CU-DIN R 8-CH 16A KNX 1.2 · 348 KB
Product
| Manufacturer | ESYLUX |
|---|---|
| Product name | CU-DIN R 8-CH 16A KNX |
| Order number | EC10430299 |
| Hardware | CU-DIN R 8-CH 16A KNX |
| Medium | Twisted Pair |
| Rail mounted | Yes |
| Registration | Registered · 2015-04-13 |
| Languages | de-DE, it-IT, en-US, da-DK, es-ES, fi-FI, fr-FR, nb-NO, nl-NL, pt-PT, ru-RU, sv-SE |
| Catalog entry | M-0080_H-2015.5F04.5F08.5F002-17-O0073_HP-20B5-12-55A9-O0073_CI-EC10430299-0 |
| Fingerprint | 55A9 |
| SHA-256 | ca256de08440b789ca19c911ca3dbfaa77f6e66bdac90faa4cfc8e6150a5e3bb |
| First seen | 2026-11-25 |
| Markets | 14 markets |
Application program: CU-DIN R 8-CH 16A KNX 1.2
| Application number | $20B5 |
|---|---|
| Version | 1.2 |
| Mask version | MV-0701 (7.1) |
| KNX Data Secure | No |
| Parameters | 1407 |
| Group objects | 226 |
Group objects (226)
| No | Name | Function | Size | DPT | Flags |
|---|---|---|---|---|---|
| 0 | Allgemein | Heartbeat | 1 Bit | 1.3 enable | CT |
| 1 | X | X | 1 Bit | CRWTU | |
| 2 | X | X | 1 Bit | CRWTU | |
| 3 | X | X | 1 Bit | CRWTU | |
| 4 | X | X | 1 Bit | CRWTU | |
| 5 | X | X | 1 Bit | CRWTU | |
| 6 | X | X | 1 Bit | CRWTU | |
| 7 | X | X | 1 Bit | CRWTU | |
| 8 | X | X | 1 Bit | CRWTU | |
| 9 | X | X | 1 Bit | CRWTU | |
| 10 | Ausgang A | Relais EIN/AUS | 1 Bit | 1.1 switch | CWU |
| 10 | Ausgang A | Heizen (Ansteuerung 1 Bit) | 1 Bit | 1.1 switch | CWU |
| 10 | Ausgang A | Heizen (Ansteuerung 1 Byte) | 1 Byte | CWU | |
| 11 | Ausgang A | Status EIN/AUS | 1 Bit | 1.1 switch | CRT |
| 12 | Ausgang A | Betriebsstunden | 2 Bytes | CRWTU | |
| 12 | Ausgang A | Zwangsführung | 1 Bit | 1.1 switch | CWU |
| 13 | Ausgang A | Alarm Betriebsstunden | 1 Bit | CRT | |
| 14 | Ausgang A | Zähler Einschaltvorgänge | 4 Bytes | 12.1 counter pulses (unsigned) | CRWTU |
| 15 | Ausgang A | Alarm Einschaltvorgänge | 1 Bit | CRT | |
| 16 | Ausgang A | Blinken EIN/AUS | 1 Bit | 1.1 switch | CWU |
| 17 | Ausgang A | Treppenhauslicht EIN/AUS | 1 Bit | 1.1 switch | CWU |
| 18 | Ausgang A | Dauer Treppenhauslicht | 2 Bytes | CWU | |
| 19 | Ausgang A | Alarm Treppenhauslicht | 1 Bit | CRT | |
| 20 | Ausgang A | Szene | 1 Byte | CWU | |
| 21 | Ausgang A | Eingang Schwellwertüberwachung | 1 Byte | 7.1 pulses | CWU |
| 21 | Ausgang A | Eingang Schwellwertüberwachung | 2 Bytes | 7.1 pulses | CWU |
| 22 | Ausgang A | Schwellwert 1 | 1 Byte | 7.1 pulses | CWU |
| 22 | Ausgang A | Schwellwert 1 | 2 Bytes | 7.1 pulses | CWU |
| 23 | Ausgang A | Schwellwert 2 | 1 Byte | 7.1 pulses | CWU |
| 23 | Ausgang A | Schwellwert 2 | 2 Bytes | 7.1 pulses | CWU |
| 24 | Ausgang A | Auf/Ab | 1 Bit | 1.8 up/down | CWU |
| 25 | Ausgang A | Stopp/Schritt | 1 Bit | CWU | |
| 25 | Ausgang A | Stopp | 1 Bit | CWU | |
| 26 | Ausgang A | Eingang Logik Block 1 | 1 Bit | 1.2 boolean | CWU |
| 27 | Ausgang A | Eingang Logik Block 2 | 1 Bit | 1.2 boolean | CWU |
| 28 | X | X | 1 Bit | CRWTU | |
| 29 | X | X | 1 Bit | CRWTU | |
| 30 | Ausgang B | Relais EIN/AUS | 1 Bit | 1.1 switch | CWU |
| 30 | Ausgang B | Heizen (Ansteuerung 1 Bit) | 1 Bit | 1.1 switch | CWU |
| 30 | Ausgang B | Heizen (Ansteuerung 1 Byte) | 1 Byte | CWU | |
| 31 | Ausgang B | Status EIN/AUS | 1 Bit | 1.1 switch | CRT |
| 32 | Ausgang B | Betriebsstunden | 2 Bytes | CRWTU | |
| 32 | Ausgang B | Zwangsführung | 1 Bit | 1.1 switch | CWU |
| 33 | Ausgang B | Alarm Betriebsstunden | 1 Bit | CRT | |
| 34 | Ausgang B | Zähler Einschaltvorgänge | 4 Bytes | 12.1 counter pulses (unsigned) | CRWTU |
| 35 | Ausgang B | Alarm Einschaltvorgänge | 1 Bit | CRT | |
| 36 | Ausgang B | Blinken EIN/AUS | 1 Bit | 1.1 switch | CWU |
| 37 | Ausgang B | Treppenhauslicht EIN/AUS | 1 Bit | 1.1 switch | CWU |
| 38 | Ausgang B | Dauer Treppenhauslicht | 2 Bytes | CWU | |
| 39 | Ausgang B | Alarm Treppenhauslicht | 1 Bit | CRT | |
| 40 | Ausgang B | Szene | 1 Byte | CWU | |
| 41 | Ausgang B | Eingang Schwellwertüberwachung | 1 Byte | 7.1 pulses | CWU |
| 41 | Ausgang B | Eingang Schwellwertüberwachung | 2 Bytes | 7.1 pulses | CWU |
| 42 | Ausgang B | Schwellwert 1 | 1 Byte | 7.1 pulses | CWU |
| 42 | Ausgang B | Schwellwert 1 | 2 Bytes | 7.1 pulses | CWU |
| 43 | Ausgang B | Schwellwert 2 | 1 Byte | 7.1 pulses | CWU |
| 43 | Ausgang B | Schwellwert 2 | 2 Bytes | 7.1 pulses | CWU |
| 44 | Ausgang B | Auf/Ab | 1 Bit | 1.8 up/down | CWU |
| 45 | Ausgang B | Stopp/Schritt | 1 Bit | CWU | |
| 45 | Ausgang B | Stopp | 1 Bit | CWU | |
| 46 | Ausgang B | Eingang Logik Block 1 | 1 Bit | 1.2 boolean | CWU |
| 47 | Ausgang B | Eingang Logik Block 2 | 1 Bit | 1.2 boolean | CWU |
| 48 | X | X | 1 Bit | CRWTU | |
| 49 | X | X | 1 Bit | CRWTU | |
| 50 | Ausgang C | Relais EIN/AUS | 1 Bit | 1.1 switch | CWU |
| 50 | Ausgang C | Heizen (Ansteuerung 1 Bit) | 1 Bit | 1.1 switch | CWU |
| 50 | Ausgang C | Heizen (Ansteuerung 1 Byte) | 1 Byte | CWU | |
| 51 | Ausgang C | Status EIN/AUS | 1 Bit | 1.1 switch | CRT |
| 52 | Ausgang C | Betriebsstunden | 2 Bytes | CRWTU | |
| 52 | Ausgang C | Zwangsführung | 1 Bit | 1.1 switch | CWU |
| 53 | Ausgang C | Alarm Betriebsstunden | 1 Bit | CRT | |
| 54 | Ausgang C | Zähler Einschaltvorgänge | 4 Bytes | 12.1 counter pulses (unsigned) | CRWTU |
| 55 | Ausgang C | Alarm Einschaltvorgänge | 1 Bit | CRT | |
| 56 | Ausgang C | Blinken EIN/AUS | 1 Bit | 1.1 switch | CWU |
| 57 | Ausgang C | Treppenhauslicht EIN/AUS | 1 Bit | 1.1 switch | CWU |
| 58 | Ausgang C | Dauer Treppenhauslicht | 2 Bytes | CWU | |
| 59 | Ausgang C | Alarm Treppenhauslicht | 1 Bit | CRT | |
| 60 | Ausgang C | Szene | 1 Byte | CWU | |
| 61 | Ausgang C | Eingang Schwellwertüberwachung | 1 Byte | 7.1 pulses | CWU |
| 61 | Ausgang C | Eingang Schwellwertüberwachung | 2 Bytes | 7.1 pulses | CWU |
| 62 | Ausgang C | Schwellwert 1 | 1 Byte | 7.1 pulses | CWU |
| 62 | Ausgang C | Schwellwert 1 | 2 Bytes | 7.1 pulses | CWU |
| 63 | Ausgang C | Schwellwert 2 | 1 Byte | 7.1 pulses | CWU |
| 63 | Ausgang C | Schwellwert 2 | 2 Bytes | 7.1 pulses | CWU |
| 64 | Ausgang C | Auf/Ab | 1 Bit | 1.8 up/down | CWU |
| 65 | Ausgang C | Stopp/Schritt | 1 Bit | CWU | |
| 65 | Ausgang C | Stopp | 1 Bit | CWU | |
| 66 | Ausgang C | Eingang Logik Block 1 | 1 Bit | 1.2 boolean | CWU |
| 67 | Ausgang C | Eingang Logik Block 2 | 1 Bit | 1.2 boolean | CWU |
| 68 | X | X | 1 Bit | CRWTU | |
| 69 | X | X | 1 Bit | CRWTU | |
| 70 | Ausgang D | Relais EIN/AUS | 1 Bit | 1.1 switch | CWU |
| 70 | Ausgang D | Heizen (Ansteuerung 1 Bit) | 1 Bit | 1.1 switch | CWU |
| 70 | Ausgang D | Heizen (Ansteuerung 1 Byte) | 1 Byte | CWU | |
| 71 | Ausgang D | Status EIN/AUS | 1 Bit | 1.1 switch | CRT |
| 72 | Ausgang D | Betriebsstunden | 2 Bytes | CRWTU | |
| 72 | Ausgang D | Zwangsführung | 1 Bit | 1.1 switch | CWU |
| 73 | Ausgang D | Alarm Betriebsstunden | 1 Bit | CRT | |
| 74 | Ausgang D | Zähler Einschaltvorgänge | 4 Bytes | 12.1 counter pulses (unsigned) | CRWTU |
| 75 | Ausgang D | Alarm Einschaltvorgänge | 1 Bit | CRT | |
| 76 | Ausgang D | Blinken EIN/AUS | 1 Bit | 1.1 switch | CWU |
| 77 | Ausgang D | Treppenhauslicht EIN/AUS | 1 Bit | 1.1 switch | CWU |
| 78 | Ausgang D | Dauer Treppenhauslicht | 2 Bytes | CWU | |
| 79 | Ausgang D | Alarm Treppenhauslicht | 1 Bit | CRT | |
| 80 | Ausgang D | Szene | 1 Byte | CWU | |
| 81 | Ausgang D | Eingang Schwellwertüberwachung | 1 Byte | 7.1 pulses | CWU |
| 81 | Ausgang D | Eingang Schwellwertüberwachung | 2 Bytes | 7.1 pulses | CWU |
| 82 | Ausgang D | Schwellwert 1 | 1 Byte | 7.1 pulses | CWU |
| 82 | Ausgang D | Schwellwert 1 | 2 Bytes | 7.1 pulses | CWU |
| 83 | Ausgang D | Schwellwert 2 | 1 Byte | 7.1 pulses | CWU |
| 83 | Ausgang D | Schwellwert 2 | 2 Bytes | 7.1 pulses | CWU |
| 84 | Ausgang D | Auf/Ab | 1 Bit | 1.8 up/down | CWU |
| 85 | Ausgang D | Stopp/Schritt | 1 Bit | CWU | |
| 85 | Ausgang D | Stopp | 1 Bit | CWU | |
| 86 | Ausgang D | Eingang Logik Block 1 | 1 Bit | 1.2 boolean | CWU |
| 87 | Ausgang D | Eingang Logik Block 2 | 1 Bit | 1.2 boolean | CWU |
| 88 | X | X | 1 Bit | CRWTU | |
| 89 | X | X | 1 Bit | CRWTU | |
| 90 | Ausgang E | Relais EIN/AUS | 1 Bit | 1.1 switch | CWU |
| 90 | Ausgang E | Heizen (Ansteuerung 1 Bit) | 1 Bit | 1.1 switch | CWU |
| 90 | Ausgang E | Heizen (Ansteuerung 1 Byte) | 1 Byte | CWU | |
| 91 | Ausgang E | Status EIN/AUS | 1 Bit | 1.1 switch | CRT |
| 92 | Ausgang E | Betriebsstunden | 2 Bytes | CRWTU | |
| 92 | Ausgang E | Zwangsführung | 1 Bit | 1.1 switch | CWU |
| 93 | Ausgang E | Alarm Betriebsstunden | 1 Bit | CRT | |
| 94 | Ausgang E | Zähler Einschaltvorgänge | 4 Bytes | 12.1 counter pulses (unsigned) | CRWTU |
| 95 | Ausgang E | Alarm Einschaltvorgänge | 1 Bit | CRT | |
| 96 | Ausgang E | Blinken EIN/AUS | 1 Bit | 1.1 switch | CWU |
| 97 | Ausgang E | Treppenhauslicht EIN/AUS | 1 Bit | 1.1 switch | CWU |
| 98 | Ausgang E | Dauer Treppenhauslicht | 2 Bytes | CWU | |
| 99 | Ausgang E | Alarm Treppenhauslicht | 1 Bit | CRT | |
| 100 | Ausgang E | Szene | 1 Byte | CWU | |
| 101 | Ausgang E | Eingang Schwellwertüberwachung | 1 Byte | 7.1 pulses | CWU |
| 101 | Ausgang E | Eingang Schwellwertüberwachung | 2 Bytes | 7.1 pulses | CWU |
| 102 | Ausgang E | Schwellwert 1 | 1 Byte | 7.1 pulses | CWU |
| 102 | Ausgang E | Schwellwert 1 | 2 Bytes | 7.1 pulses | CWU |
| 103 | Ausgang E | Schwellwert 2 | 1 Byte | 7.1 pulses | CWU |
| 103 | Ausgang E | Schwellwert 2 | 2 Bytes | 7.1 pulses | CWU |
| 104 | Ausgang E | Auf/Ab | 1 Bit | 1.8 up/down | CWU |
| 105 | Ausgang E | Stopp/Schritt | 1 Bit | CWU | |
| 105 | Ausgang E | Stopp | 1 Bit | CWU | |
| 106 | Ausgang E | Eingang Logik Block 1 | 1 Bit | 1.2 boolean | CWU |
| 107 | Ausgang E | Eingang Logik Block 2 | 1 Bit | 1.2 boolean | CWU |
| 108 | X | X | 1 Bit | CRWTU | |
| 109 | X | X | 1 Bit | CRWTU | |
| 110 | Ausgang F | Relais EIN/AUS | 1 Bit | 1.1 switch | CWU |
| 110 | Ausgang F | Heizen (Ansteuerung 1 Bit) | 1 Bit | 1.1 switch | CWU |
| 110 | Ausgang F | Heizen (Ansteuerung 1 Byte) | 1 Byte | CWU | |
| 111 | Ausgang F | Status EIN/AUS | 1 Bit | 1.1 switch | CRT |
| 112 | Ausgang F | Betriebsstunden | 2 Bytes | CRWTU | |
| 112 | Ausgang F | Zwangsführung | 1 Bit | 1.1 switch | CWU |
| 113 | Ausgang F | Alarm Betriebsstunden | 1 Bit | CRT | |
| 114 | Ausgang F | Zähler Einschaltvorgänge | 4 Bytes | 12.1 counter pulses (unsigned) | CRWTU |
| 115 | Ausgang F | Alarm Einschaltvorgänge | 1 Bit | CRT | |
| 116 | Ausgang F | Blinken EIN/AUS | 1 Bit | 1.1 switch | CWU |
| 117 | Ausgang F | Treppenhauslicht EIN/AUS | 1 Bit | 1.1 switch | CWU |
| 118 | Ausgang F | Dauer Treppenhauslicht | 2 Bytes | CWU | |
| 119 | Ausgang F | Alarm Treppenhauslicht | 1 Bit | CRT | |
| 120 | Ausgang F | Szene | 1 Byte | CWU | |
| 121 | Ausgang F | Eingang Schwellwertüberwachung | 1 Byte | 7.1 pulses | CWU |
| 121 | Ausgang F | Eingang Schwellwertüberwachung | 2 Bytes | 7.1 pulses | CWU |
| 122 | Ausgang F | Schwellwert 1 | 1 Byte | 7.1 pulses | CWU |
| 122 | Ausgang F | Schwellwert 1 | 2 Bytes | 7.1 pulses | CWU |
| 123 | Ausgang F | Schwellwert 2 | 1 Byte | 7.1 pulses | CWU |
| 123 | Ausgang F | Schwellwert 2 | 2 Bytes | 7.1 pulses | CWU |
| 124 | Ausgang F | Auf/Ab | 1 Bit | 1.8 up/down | CWU |
| 125 | Ausgang F | Stopp/Schritt | 1 Bit | CWU | |
| 125 | Ausgang F | Stopp | 1 Bit | CWU | |
| 126 | Ausgang F | Eingang Logik Block 1 | 1 Bit | 1.2 boolean | CWU |
| 127 | Ausgang F | Eingang Logik Block 2 | 1 Bit | 1.2 boolean | CWU |
| 128 | X | X | 1 Bit | CRWTU | |
| 129 | X | X | 1 Bit | CRWTU | |
| 130 | Ausgang G | Relais EIN/AUS | 1 Bit | 1.1 switch | CWU |
| 130 | Ausgang G | Heizen (Ansteuerung 1 Bit) | 1 Bit | 1.1 switch | CWU |
| 130 | Ausgang G | Heizen (Ansteuerung 1 Byte) | 1 Byte | CWU | |
| 131 | Ausgang G | Status EIN/AUS | 1 Bit | 1.1 switch | CRT |
| 132 | Ausgang G | Betriebsstunden | 2 Bytes | CRWTU | |
| 132 | Ausgang G | Zwangsführung | 1 Bit | 1.1 switch | CWU |
| 133 | Ausgang G | Alarm Betriebsstunden | 1 Bit | CRT | |
| 134 | Ausgang G | Zähler Einschaltvorgänge | 4 Bytes | 12.1 counter pulses (unsigned) | CRWTU |
| 135 | Ausgang G | Alarm Einschaltvorgänge | 1 Bit | CRT | |
| 136 | Ausgang G | Blinken EIN/AUS | 1 Bit | 1.1 switch | CWU |
| 137 | Ausgang G | Treppenhauslicht EIN/AUS | 1 Bit | 1.1 switch | CWU |
| 138 | Ausgang G | Dauer Treppenhauslicht | 2 Bytes | CWU | |
| 139 | Ausgang G | Alarm Treppenhauslicht | 1 Bit | CRT | |
| 140 | Ausgang G | Szene | 1 Byte | CWU | |
| 141 | Ausgang G | Eingang Schwellwertüberwachung | 1 Byte | 7.1 pulses | CWU |
| 141 | Ausgang G | Eingang Schwellwertüberwachung | 2 Bytes | 7.1 pulses | CWU |
| 142 | Ausgang G | Schwellwert 1 | 1 Byte | 7.1 pulses | CWU |
| 142 | Ausgang G | Schwellwert 1 | 2 Bytes | 7.1 pulses | CWU |
| 143 | Ausgang G | Schwellwert 2 | 1 Byte | 7.1 pulses | CWU |
| 143 | Ausgang G | Schwellwert 2 | 2 Bytes | 7.1 pulses | CWU |
| 144 | Ausgang G | Auf/Ab | 1 Bit | 1.8 up/down | CWU |
| 145 | Ausgang G | Stopp/Schritt | 1 Bit | CWU | |
| 145 | Ausgang G | Stopp | 1 Bit | CWU | |
| 146 | Ausgang G | Eingang Logik Block 1 | 1 Bit | 1.2 boolean | CWU |
| 147 | Ausgang G | Eingang Logik Block 2 | 1 Bit | 1.2 boolean | CWU |
| 148 | X | X | 1 Bit | CRWTU | |
| 149 | X | X | 1 Bit | CRWTU | |
| 150 | Ausgang H | Relais EIN/AUS | 1 Bit | 1.1 switch | CWU |
| 150 | Ausgang H | Heizen (Ansteuerung 1 Bit) | 1 Bit | 1.1 switch | CWU |
| 150 | Ausgang H | Heizen (Ansteuerung 1 Byte) | 1 Byte | CWU | |
| 151 | Ausgang H | Status EIN/AUS | 1 Bit | 1.1 switch | CRT |
| 152 | Ausgang H | Betriebsstunden | 2 Bytes | CRWTU | |
| 152 | Ausgang H | Zwangsführung | 1 Bit | 1.1 switch | CWU |
| 153 | Ausgang H | Alarm Betriebsstunden | 1 Bit | CRT | |
| 154 | Ausgang H | Zähler Einschaltvorgänge | 4 Bytes | 12.1 counter pulses (unsigned) | CRWTU |
| 155 | Ausgang H | Alarm Einschaltvorgänge | 1 Bit | CRT | |
| 156 | Ausgang H | Blinken EIN/AUS | 1 Bit | 1.1 switch | CWU |
| 157 | Ausgang H | Treppenhauslicht EIN/AUS | 1 Bit | 1.1 switch | CWU |
| 158 | Ausgang H | Dauer Treppenhauslicht | 2 Bytes | CWU | |
| 159 | Ausgang H | Alarm Treppenhauslicht | 1 Bit | CRT | |
| 160 | Ausgang H | Szene | 1 Byte | CWU | |
| 161 | Ausgang H | Eingang Schwellwertüberwachung | 1 Byte | 7.1 pulses | CWU |
| 161 | Ausgang H | Eingang Schwellwertüberwachung | 2 Bytes | 7.1 pulses | CWU |
| 162 | Ausgang H | Schwellwert 1 | 1 Byte | 7.1 pulses | CWU |
| 162 | Ausgang H | Schwellwert 1 | 2 Bytes | 7.1 pulses | CWU |
| 163 | Ausgang H | Schwellwert 2 | 1 Byte | 7.1 pulses | CWU |
| 163 | Ausgang H | Schwellwert 2 | 2 Bytes | 7.1 pulses | CWU |
| 164 | Ausgang H | Auf/Ab | 1 Bit | 1.8 up/down | CWU |
| 165 | Ausgang H | Stopp/Schritt | 1 Bit | CWU | |
| 165 | Ausgang H | Stopp | 1 Bit | CWU | |
| 166 | Ausgang H | Eingang Logik Block 1 | 1 Bit | 1.2 boolean | CWU |
| 167 | Ausgang H | Eingang Logik Block 2 | 1 Bit | 1.2 boolean | CWU |
| 168 | X | X | 1 Bit | CRWTU | |
| 169 | X | X | 1 Bit | CRWTU |
Parameters (113)
| Parameter | Type | Default |
|---|---|---|
| Verzögerung Start Applikation nach Busspannungswiederkehr (2…200 Sek.) | unsignedInt 2…200 | 2 |
| Heartbeat | list | Nicht aktiv |
| NULL | list | Nein |
| -Zeitabstand für zyklisches Senden (1...65535 Sek.) | unsignedInt 1…65535 | 5 |
| Betriebsspannung Relais | list | 13V |
| Dauer Einschaltimpuls Relais | list | 20 ms. |
| Kanal A Betriebsart | list | Schaltaktor |
| Schaltfunktion | list | Schließer |
| Statusobjekt | list | Nicht aktiv |
| Betriebsstundenzähler (bei eingeschaltetem Relais) | list | Nicht aktiv |
| ->Ausgabe Alarm, wenn Grenzwert Betriebsstunden erreicht | list | Nein |
| —Grenzwert Betriebsstunden (1…65535 Std.) | unsignedInt 1…65535 | 30000 |
| --Zeitabstand der Alarm-Meldungen (1…255 Sek.) | unsignedInt 1…255 | 10 |
| --Anzahl Telegrammwiederholungen bei Alarm (1…255, 0 = keine Begrenzung) | unsignedInt 0…255 | 0 |
| Zähler für Einschaltvorgänge des Relais (4 Byte) | list | Nicht aktiv |
| ->Alarmausgabe wenn Zählergrenzwert erreicht | list | Nein |
| —Grenzwert Einschaltvorgänge (10...10000000) | unsignedInt 10…10000000 | 100000 |
| --Zeitabstand für Ausgabe von Alarm Einschaltvorgänge (1…255 Sek.) | unsignedInt 1…255 | 10 |
| Relaiszustand bei Busspannungsabfall | list | Keine Änderung |
| Relaiszustand bei Busspannungswiederkehr | list | Keine Änderung |
| Zusatzfunktionen=>> | list | Nein |
| Zusatzfunktion "Zeitfunktionen" | list | Nicht aktiv |
| Zusatzfunktion "Szenen" | list | Nicht aktiv |
| Zusatzfunktion "Schwellwertüberwachung" | list | Nicht aktiv |
| Zusatzfunktion "Jalousie" | list | Nicht aktiv |
| Zusatzfunktion "Logik-Modul" | list | Nicht aktiv |
| Zeitfunktion | list | Blinken EIN/AUS |
| Start/Stopp Blinken | list | Start bei EIN, Stopp bei AUS |
| >>Einschaltdauer (0…255 Min.) | unsignedInt 0…255 | 0 |
| --Einschaltdauer (0…59 Sek.) | unsignedInt 0…59 | 5 |
| >>Ausschaltdauer (0…255 Min.) | unsignedInt 0…255 | 0 |
| --Ausschaltdauer (0…59 Sek.) | unsignedInt 0…59 | 5 |
| Blinkzyklen (1…100, 0 = keine Begrenzung) | unsignedInt 0…100 | 0 |
| Zustand nach Beenden von Blinken | list | Keine Änderung |
| Start/Stopp Treppenhauslicht | list | Start bei EIN, Stopp bei AUS |
| Vorgabe Dauer Treppenhauslicht über Telegramm | list | Nein |
| Statusobjekt Treppenhauslicht | list | Nein |
| Ausschaltwarnung Treppenhauslicht (AN->AUS->AN) | list | Nein |
| --Ausschaltwarnzeit (3…255 Sek.) | unsignedInt 3…255 | 3 |
| --Dauer der Auschaltwarnung (1…200 Sek.) | unsignedInt 1…200 | 1 |
| >>Einschaltverzögerung im normalen Betrieb (0…255 Min.) | unsignedInt 0…255 | 0 |
| --Einschaltverzögerung im normalen Betrieb (0…59 Sek.) | unsignedInt 0…59 | 0 |
| >>Ausschaltverzögerung im normalen Betrieb (0…255 Min.) | unsignedInt 0…255 | 0 |
| --Ausschaltverzögerung im normalen Betrieb (0…59 Sek.) | unsignedInt 0…59 | 0 |
| >>Einschaltverzögerung im Schutzbetrieb (0…255 Min.) | unsignedInt 0…255 | 0 |
| --Einschaltverzögerung im Schutzbetrieb (0…59 Sek.) | unsignedInt 0…59 | 0 |
| >>Ausschaltverzögerung im Schutzbetrieb (0…255 Min.) | unsignedInt 0…255 | 0 |
| --Ausschaltverzögerung im Schutzbetrieb (0…59 Sek.) | unsignedInt 0…59 | 0 |
| >>Ausgang zugeordnet zu (Szene 1…64) | list | Nicht aktiv |
| --Schaltzustand | list | AUS |
| --Ein-/Ausschaltverzögerung | list | Nicht aktiv |
| --Einschaltverzögerung: (0…255 Min.) | unsignedInt 0…255 | 0 |
| --Einschaltverzögerung: (0…59 Sek.) | unsignedInt 0…59 | 5 |
| --Ausschaltverzögerung: (0…255 Min.) | unsignedInt 0…255 | 0 |
| --Ausschaltverzögerung: (0…59 Sek.) | unsignedInt 0…59 | 0 |
| Typ des Eingangsobjekts | list | 1 Byte (0...255) |
| --Vorgabe Schwellwert 1 über Telegramm | list | Nein |
| --Vorgabe Schwellwert 2 über Telegramm | list | Nein |
| ->Schwellwert 1 (0…255) | unsignedInt 0…255 | 80 |
| ->Schwellwert 2 (0…255) | unsignedInt 0…255 | 180 |
| Eingang Schwellwertüberwachung nach Busspannungswiederkehr (0…255) | unsignedInt 0…255 | 0 |
| ->Schwellwert 1 (0…65535) | unsignedInt 0…65535 | 10000 |
| ->Schwellwert 2 (0…65535) | unsignedInt 0…65535 | 30000 |
| Eingang Schwellwertüberwachung nach Busspannungswiederkehr (0…65535) | unsignedInt 0…65535 | 0 |
| ->Ausgang, wenn Eingangsobjekt < niedriger Schwellwert | list | EIN |
| ->Ausgang, wenn Eingangsobjekt zwischen den Schwellwerten | list | Keine Änderung |
| ->Ausgang, wenn Eingangsobjekt > hoher Schwellwert | list | AUS |
| Jalousie auf (Telegrammwert: 0) | list | Kanal A |
| Jalousie ab (Telegrammwert: 1) | list | Kanal B |
| Ansteuerung | list | Auf/Ab und Stopp/Schritt |
| Laufzeit bei Schrittbefehl | list | 100 ms. |
| Verzögerungszeit bei Richtungswechsel | list | 200 ms. |
| Fahrtzeit (2…65535 Sek.) | unsignedInt 2…65535 | 10 |
| Logik Block 1 | list | Nicht aktiv |
| Logische Verknüpfung von Block 1 | list | UND |
| Wert von Eingangsobjekt Logik Block 1 nach Busspannungswiederkehr | list | 0 |
| Ausgang von Logik Block 1 invertieren | list | Nein |
| Logik Block 2 | list | Nicht aktiv |
| Logische Verknüpfung von Block 2 | list | UND |
| Wert von Eingangsobjekt Logik Block 2 nach Busspannungswiederkehr | list | 0 |
| Ausgang von Logik Block 2 invertieren | list | Nein |
| Zustand des Relais bei Busspannungsabfall | list | Keine Änderung |
| Zustand des Relais bei Busspannungswiederkehr | list | Keine Änderung |
| >>PWM Zykluszeit (1….65535 Min.) | unsignedInt 1…65535 | 1 |
| >>PWM Zykluszeit (0…59 Sek.) | unsignedInt 0…59 | 0 |
| Ansteuerung | list | Binär (EIN: Start, AUS: Stopp) |
| Rückmeldeobjekt | list | Nicht aktiv |
| Tastgrad der PWM im normalen Betrieb | list | 50% (128) |
| Ventilansteuerung nach Busspannungswiederkehr | list | Nein |
| --Tastgrad | list | 50% (128) |
| Zwangsführung Ventil | list | Nein |
| --Aktion bei Rücknahme der Zwangsführung | list | Rückkehr in den Normalbetrieb |
| Kanal B Betriebsart | list | Schaltaktor |
| Jalousie auf (Telegrammwert: 0) | list | Kanal B |
| Jalousie ab (Telegrammwert: 1) | list | Kanal C |
| Kanal C Betriebsart | list | Schaltaktor |
| Jalousie auf (Telegrammwert: 0) | list | Kanal C |
| Jalousie ab (Telegrammwert: 1) | list | Kanal D |
| Kanal D Betriebsart | list | Schaltaktor |
| Jalousie auf (Telegrammwert: 0) | list | Kanal D |
| Jalousie ab (Telegrammwert: 1) | list | Kanal E |
| Kanal E Betriebsart | list | Schaltaktor |
| Jalousie auf (Telegrammwert: 0) | list | Kanal E |
| Jalousie ab (Telegrammwert: 1) | list | Kanal F |
| Kanal F Betriebsart | list | Schaltaktor |
| Jalousie auf (Telegrammwert: 0) | list | Kanal F |
| Jalousie ab (Telegrammwert: 1) | list | Kanal G |
| Kanal G Betriebsart | list | Schaltaktor |
| Jalousie auf (Telegrammwert: 0) | list | Kanal G |
| Jalousie ab (Telegrammwert: 1) | list | Kanal H |
| Kanal H Betriebsart | list | Schaltaktor |
| Jalousie auf (Telegrammwert: 0) | list | Kanal H |
| Jalousie ab (Telegrammwert: 1) | list | Kanal A |
Version history
| Application | App no | Fingerprint | First seen | Size | File |
|---|---|---|---|---|---|
| CU-DIN R 8-CH 16A KNX 1.2 latest | $20B5 | 55A9 | 2026-11-25 | 348 KB | Download |
About this file
This is the official ETS product database for the ESYLUX CU-DIN R 8-CH 16A KNX (EC10430299), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.
More from ESYLUX
- CU-DIN R 4-CH 16A KNX EC10430282
- CU-DIN R 12-CH 16A KNX EC10430305
- CU-DIN DIM 4-CH 1.5A KNX EC10430312
- CU-DIN DIM 6-CH 0…10V KNX EC10430329
- CU-DIN SB 2-CH 10A KNX EC10430343
- CU-DIN SB 4-CH 10A KNX EC10430350
- CU-DIN SB 6-CH 10A KNX EC10430367
- CU-DIN HVAC KNX EC10430503
- ESYLUX PD360/8 Basic KNX EB10430442
- CU-DIN DRY 4-Z KNX EC10430381
- CU-DIN IPRT KNX EC10430527
- CU-DIN LC KNX EC10430534