KNX Metering gateway wM-Bus/M-Bus 13516140
ELKA-Elektronik GmbH · Order number 13516140 · Gateways › Gateways Messdatenerfassung
Download .knxprod KNX Metering gateway C01911 1.1 · 722 KB
Product
| Manufacturer | ELKA-Elektronik GmbH |
|---|---|
| Product name | KNX Metering gateway wM-Bus/M-Bus |
| Order number | 13516140 |
| Product text | KNX Messstellengateway wM-Bus/M-Bus |
| Hardware | KNX Messstellengateway |
| Medium | Twisted Pair |
| Bus current (mA) | 5 |
| Rail mounted | Yes |
| Width (mm) | 72 |
| Registration | Registered · 2015-12-07 |
| Languages | de-DE, en-US |
| Catalog entry | M-00F4_H-F4.20.2F.2F.2013516140-0_HP-C019-11-293F_CI-13516140-1 |
| Fingerprint | 293F |
| SHA-256 | 094ce6281fb70c8ebb97d6a05f30a28b3988125aed63ca53f9237111134d6f42 |
| First seen | 2026-11-25 |
| Markets | China, Germany, United Kingdom |
Application program: KNX Messstellengateway C01911 1.1
| Application number | $C019 |
|---|---|
| Version | 1.1 |
| Mask version | MV-07B0 (System B) |
| KNX Data Secure | No |
| Minimum ETS version | 4.0 |
| Parameters | 6046 |
| Group objects | 24357 |
Group objects (24357)
| No | Name | Function | Size | DPT | Flags |
|---|---|---|---|---|---|
| 1 | Wiederkehr der Versorgungsspannung | Allgemein | 1 Bit | 1.1 switch | CT |
| 2 | Uhrzeit/Datum anfordern | Allgemein | 1 Bit | 1.1 switch | CT |
| 3 | Uhrzeit stellen | Allgemein | 3 Bytes | 10.1 time of day | CWT |
| 4 | Datum stellen | Allgemein | 3 Bytes | 11.1 date | CWT |
| 5 | Masteruhr Uhrzeit/Datum Anforderung | Allgemein | 1 Bit | 1.1 switch | CWT |
| 6 | Masteruhr Uhrzeit | Allgemein | 3 Bytes | 10.1 time of day | CT |
| 7 | Masteruhr Datum | Allgemein | 3 Bytes | 11.1 date | CT |
| 60 | S0-Kurzschluß | S0 1 | 1 Bit | 1.1 switch | CT |
| 61 | Sende-Anforderung | S0 1 | 1 Bit | 1.1 switch | CW |
| 80 | Momentanwert Verbrauch bzw. Volumen | S0 1 | 8 Bytes | 29.10 active energy (Wh) | CT |
| 80 | Momentanwert Verbrauch bzw. Volumen | S0 1 | 4 Bytes | 13.10 active energy (Wh) | CT |
| 80 | Momentanwert Verbrauch bzw. Volumen | S0 1 | 4 Bytes | 13.13 active energy (kWh) | CT |
| 80 | Momentanwert Verbrauch bzw. Volumen | S0 1 | 4 Bytes | 14.76 volume (m³) | CT |
| 81 | Momentanwert Leistung bzw. Durchfluss | S0 1 | 4 Bytes | 13.2 flow rate (m³/h) | CT |
| 81 | Momentanwert Leistung bzw. Durchfluss | S0 1 | 2 Bytes | 9.24 power (kW) | CT |
| 81 | Momentanwert Leistung bzw. Durchfluss | S0 1 | 2 Bytes | 9.25 volume flow (l/h) | CT |
| 81 | Momentanwert Leistung bzw. Durchfluss | S0 1 | 4 Bytes | 14.56 power (W) | CT |
| 115 | Verbrauch letzte Stunde | S0 1 | 4 Bytes | 13.10 active energy (Wh) | CT |
| 115 | Verbrauch letzte Stunde | S0 1 | 4 Bytes | 13.13 active energy (kWh) | CT |
| 115 | Verbrauch letzte Stunde | S0 1 | 8 Bytes | 29.10 active energy (Wh) | CT |
| 115 | Verbrauch letzte Stunde | S0 1 | 4 Bytes | 14.76 volume (m³) | CT |
| 116 | Verbrauch letzter Tag | S0 1 | 4 Bytes | 14.76 volume (m³) | CT |
| 116 | Verbrauch letzter Tag | S0 1 | 8 Bytes | 29.10 active energy (Wh) | CT |
| 116 | Verbrauch letzter Tag | S0 1 | 4 Bytes | 13.10 active energy (Wh) | CT |
| 116 | Verbrauch letzter Tag | S0 1 | 4 Bytes | 13.13 active energy (kWh) | CT |
| 117 | Verbrauch letzte Woche | S0 1 | 8 Bytes | 29.10 active energy (Wh) | CT |
| 117 | Verbrauch letzte Woche | S0 1 | 4 Bytes | 14.76 volume (m³) | CT |
| 117 | Verbrauch letzte Woche | S0 1 | 4 Bytes | 13.10 active energy (Wh) | CT |
| 117 | Verbrauch letzte Woche | S0 1 | 4 Bytes | 13.13 active energy (kWh) | CT |
| 118 | Verbrauch letzter Monat | S0 1 | 8 Bytes | 29.10 active energy (Wh) | CT |
| 118 | Verbrauch letzter Monat | S0 1 | 4 Bytes | 13.10 active energy (Wh) | CT |
| 118 | Verbrauch letzter Monat | S0 1 | 4 Bytes | 14.76 volume (m³) | CT |
| 118 | Verbrauch letzter Monat | S0 1 | 4 Bytes | 13.13 active energy (kWh) | CT |
| 120 | S0-Kurzschluß | S0 2 | 1 Bit | 1.1 switch | CT |
| 121 | Sende-Anforderung | S0 2 | 1 Bit | 1.1 switch | CW |
| 140 | Momentanwert Verbrauch bzw. Volumen | S0 2 | 4 Bytes | 13.10 active energy (Wh) | CT |
| 140 | Momentanwert Verbrauch bzw. Volumen | S0 2 | 4 Bytes | 13.13 active energy (kWh) | CT |
| 140 | Momentanwert Verbrauch bzw. Volumen | S0 2 | 4 Bytes | 14.76 volume (m³) | CT |
| 140 | Momentanwert Verbrauch bzw. Volumen | S0 2 | 8 Bytes | 29.10 active energy (Wh) | CT |
| 141 | Momentanwert Leistung bzw. Durchfluss | S0 2 | 2 Bytes | 9.24 power (kW) | CT |
| 141 | Momentanwert Leistung bzw. Durchfluss | S0 2 | 2 Bytes | 9.25 volume flow (l/h) | CT |
| 141 | Momentanwert Leistung bzw. Durchfluss | S0 2 | 4 Bytes | 13.2 flow rate (m³/h) | CT |
| 141 | Momentanwert Leistung bzw. Durchfluss | S0 2 | 4 Bytes | 14.56 power (W) | CT |
| 175 | Verbrauch letzte Stunde | S0 2 | 4 Bytes | 13.10 active energy (Wh) | CT |
| 175 | Verbrauch letzte Stunde | S0 2 | 4 Bytes | 13.13 active energy (kWh) | CT |
| 175 | Verbrauch letzte Stunde | S0 2 | 4 Bytes | 14.76 volume (m³) | CT |
| 175 | Verbrauch letzte Stunde | S0 2 | 8 Bytes | 29.10 active energy (Wh) | CT |
| 176 | Verbrauch letzter Tag | S0 2 | 4 Bytes | 13.10 active energy (Wh) | CT |
| 176 | Verbrauch letzter Tag | S0 2 | 4 Bytes | 13.13 active energy (kWh) | CT |
| 176 | Verbrauch letzter Tag | S0 2 | 4 Bytes | 14.76 volume (m³) | CT |
| 176 | Verbrauch letzter Tag | S0 2 | 8 Bytes | 29.10 active energy (Wh) | CT |
| 177 | Verbrauch letzte Woche | S0 2 | 4 Bytes | 13.10 active energy (Wh) | CT |
| 177 | Verbrauch letzte Woche | S0 2 | 4 Bytes | 13.13 active energy (kWh) | CT |
| 177 | Verbrauch letzte Woche | S0 2 | 4 Bytes | 14.76 volume (m³) | CT |
| 177 | Verbrauch letzte Woche | S0 2 | 8 Bytes | 29.10 active energy (Wh) | CT |
| 178 | Verbrauch letzter Monat | S0 2 | 4 Bytes | 13.10 active energy (Wh) | CT |
| 178 | Verbrauch letzter Monat | S0 2 | 4 Bytes | 13.13 active energy (kWh) | CT |
| 178 | Verbrauch letzter Monat | S0 2 | 4 Bytes | 14.76 volume (m³) | CT |
| 178 | Verbrauch letzter Monat | S0 2 | 8 Bytes | 29.10 active energy (Wh) | CT |
| 180 | D0 Aktiv | D0 | 1 Bit | 1.1 switch | CT |
| 181 | Sende-Anforderung | D0 | 1 Bit | 1.1 switch | CW |
| 200 | Zähler Datensatz 1 | D0 | 8 Bytes | 29.12 reactive energy (VARh) | CT |
| 200 | Zähler Datensatz 1 | D0 | 8 Bytes | 29.11 apparant energy (VAh) | CT |
| 200 | Zähler Datensatz 1 | D0 | 8 Bytes | 29.10 active energy (Wh) | CT |
| 200 | Zähler Datensatz 1 | D0 | 4 Bytes | 14.68 temperature (°C) | CT |
| 200 | Zähler Datensatz 1 | D0 | 4 Bytes | 14.57 power factor (cos Φ) | CT |
| 200 | Zähler Datensatz 1 | D0 | 4 Bytes | 14.56 power (W) | CT |
| 200 | Zähler Datensatz 1 | D0 | 4 Bytes | 14.76 volume (m³) | CT |
| 200 | Zähler Datensatz 1 | D0 | 4 Bytes | 14.31 energy (J) | CT |
| 200 | Zähler Datensatz 1 | D0 | 1 Bit | 1.15 reset | CT |
| 200 | Zähler Datensatz 1 | D0 | 2 Bytes | 7.5 time (s) | CT |
| 200 | Zähler Datensatz 1 | D0 | 2 Bytes | 9.21 current (mA) | CT |
| 200 | Zähler Datensatz 1 | D0 | 2 Bytes | 7.7 time (h) | CT |
| 200 | Zähler Datensatz 1 | D0 | 2 Bytes | 9.2 temperature difference (K) | CT |
| 200 | Zähler Datensatz 1 | D0 | 2 Bytes | 9.3 kelvin/hour (K/h) | CT |
| 200 | Zähler Datensatz 1 | D0 | 2 Bytes | 9.6 pressure (Pa) | CT |
| 200 | Zähler Datensatz 1 | D0 | 2 Bytes | 9.10 time (s) | CT |
| 200 | Zähler Datensatz 1 | D0 | 2 Bytes | 9.1 temperature (°C) | CT |
| 200 | Zähler Datensatz 1 | D0 | 1 Bit | 1.10 start/stop | CT |
| 200 | Zähler Datensatz 1 | D0 | 1 Bit | 1.3 enable | CT |
| 200 | Zähler Datensatz 1 | D0 | 1 Bit | 1.1 switch | CT |
| 200 | Zähler Datensatz 1 | D0 | 2 Bytes | 9.20 voltage (mV) | CT |
| 200 | Zähler Datensatz 1 | D0 | 2 Bytes | 9.24 power (kW) | CT |
| 200 | Zähler Datensatz 1 | D0 | 4 Bytes | 13.11 apparant energy (VAh) | CT |
| 200 | Zähler Datensatz 1 | D0 | 2 Bytes | 9.27 temperature (°F) | CT |
| 200 | Zähler Datensatz 1 | D0 | 4 Bytes | 14.19 electric current (A) | CT |
| 200 | Zähler Datensatz 1 | D0 | 4 Bytes | 13.100 time lag (s) | CT |
| 200 | Zähler Datensatz 1 | D0 | 4 Bytes | 13.15 reactive energy (kVARh) | CT |
| 200 | Zähler Datensatz 1 | D0 | 4 Bytes | 12.1 counter pulses (unsigned) | CT |
| 200 | Zähler Datensatz 1 | D0 | 3 Bytes | 11.1 date | CT |
| 200 | Zähler Datensatz 1 | D0 | 3 Bytes | 10.1 time of day | CT |
| 200 | Zähler Datensatz 1 | D0 | 2 Bytes | 9.25 volume flow (l/h) | CT |
| 200 | Zähler Datensatz 1 | D0 | 4 Bytes | 13.14 apparent energy (kVAh) | CT |
| 200 | Zähler Datensatz 1 | D0 | 4 Bytes | 13.2 flow rate (m³/h) | CT |
| 200 | Zähler Datensatz 1 | D0 | 4 Bytes | 13.10 active energy (Wh) | CT |
| 200 | Zähler Datensatz 1 | D0 | 4 Bytes | 13.12 reactive energy (VARh) | CT |
| 200 | Zähler Datensatz 1 | D0 | 4 Bytes | 14.27 electric potential (V) | CT |
| 200 | Zähler Datensatz 1 | D0 | 4 Bytes | 13.13 active energy (kWh) | CT |
| 200 | Zähler Datensatz 1 | D0 | 4 Bytes | 14.33 frequency (Hz) | CT |
| 201 | Zähler Datensatz 2 | D0 | 1 Bit | 1.1 switch | CT |
| 201 | Zähler Datensatz 2 | D0 | 1 Bit | 1.3 enable | CT |
| 201 | Zähler Datensatz 2 | D0 | 1 Bit | 1.10 start/stop | CT |
| 201 | Zähler Datensatz 2 | D0 | 1 Bit | 1.15 reset | CT |
| 201 | Zähler Datensatz 2 | D0 | 2 Bytes | 7.5 time (s) | CT |
| 201 | Zähler Datensatz 2 | D0 | 2 Bytes | 7.7 time (h) | CT |
| 201 | Zähler Datensatz 2 | D0 | 2 Bytes | 9.1 temperature (°C) | CT |
| 201 | Zähler Datensatz 2 | D0 | 2 Bytes | 9.2 temperature difference (K) | CT |
| 201 | Zähler Datensatz 2 | D0 | 2 Bytes | 9.3 kelvin/hour (K/h) | CT |
| 201 | Zähler Datensatz 2 | D0 | 2 Bytes | 9.6 pressure (Pa) | CT |
| 201 | Zähler Datensatz 2 | D0 | 2 Bytes | 9.10 time (s) | CT |
| 201 | Zähler Datensatz 2 | D0 | 2 Bytes | 9.20 voltage (mV) | CT |
| 201 | Zähler Datensatz 2 | D0 | 2 Bytes | 9.21 current (mA) | CT |
| 201 | Zähler Datensatz 2 | D0 | 2 Bytes | 9.24 power (kW) | CT |
| 201 | Zähler Datensatz 2 | D0 | 2 Bytes | 9.25 volume flow (l/h) | CT |
| 201 | Zähler Datensatz 2 | D0 | 2 Bytes | 9.27 temperature (°F) | CT |
| 201 | Zähler Datensatz 2 | D0 | 3 Bytes | 10.1 time of day | CT |
| 201 | Zähler Datensatz 2 | D0 | 3 Bytes | 11.1 date | CT |
| 201 | Zähler Datensatz 2 | D0 | 4 Bytes | 12.1 counter pulses (unsigned) | CT |
| 201 | Zähler Datensatz 2 | D0 | 4 Bytes | 13.2 flow rate (m³/h) | CT |
| 201 | Zähler Datensatz 2 | D0 | 4 Bytes | 13.10 active energy (Wh) | CT |
| 201 | Zähler Datensatz 2 | D0 | 4 Bytes | 13.11 apparant energy (VAh) | CT |
| 201 | Zähler Datensatz 2 | D0 | 4 Bytes | 13.12 reactive energy (VARh) | CT |
| 201 | Zähler Datensatz 2 | D0 | 4 Bytes | 13.13 active energy (kWh) | CT |
| 201 | Zähler Datensatz 2 | D0 | 4 Bytes | 13.14 apparent energy (kVAh) | CT |
| 201 | Zähler Datensatz 2 | D0 | 4 Bytes | 13.15 reactive energy (kVARh) | CT |
| 201 | Zähler Datensatz 2 | D0 | 4 Bytes | 13.100 time lag (s) | CT |
| 201 | Zähler Datensatz 2 | D0 | 4 Bytes | 14.19 electric current (A) | CT |
| 201 | Zähler Datensatz 2 | D0 | 4 Bytes | 14.27 electric potential (V) | CT |
| 201 | Zähler Datensatz 2 | D0 | 4 Bytes | 14.31 energy (J) | CT |
| 201 | Zähler Datensatz 2 | D0 | 4 Bytes | 14.33 frequency (Hz) | CT |
| 201 | Zähler Datensatz 2 | D0 | 4 Bytes | 14.56 power (W) | CT |
| 201 | Zähler Datensatz 2 | D0 | 4 Bytes | 14.57 power factor (cos Φ) | CT |
| 201 | Zähler Datensatz 2 | D0 | 4 Bytes | 14.68 temperature (°C) | CT |
| 201 | Zähler Datensatz 2 | D0 | 4 Bytes | 14.76 volume (m³) | CT |
| 201 | Zähler Datensatz 2 | D0 | 8 Bytes | 29.10 active energy (Wh) | CT |
| 201 | Zähler Datensatz 2 | D0 | 8 Bytes | 29.11 apparant energy (VAh) | CT |
| 201 | Zähler Datensatz 2 | D0 | 8 Bytes | 29.12 reactive energy (VARh) | CT |
| 202 | Zähler Datensatz 3 | D0 | 1 Bit | 1.1 switch | CT |
| 202 | Zähler Datensatz 3 | D0 | 1 Bit | 1.3 enable | CT |
| 202 | Zähler Datensatz 3 | D0 | 1 Bit | 1.10 start/stop | CT |
| 202 | Zähler Datensatz 3 | D0 | 1 Bit | 1.15 reset | CT |
| 202 | Zähler Datensatz 3 | D0 | 2 Bytes | 7.5 time (s) | CT |
| 202 | Zähler Datensatz 3 | D0 | 2 Bytes | 7.7 time (h) | CT |
| 202 | Zähler Datensatz 3 | D0 | 2 Bytes | 9.1 temperature (°C) | CT |
| 202 | Zähler Datensatz 3 | D0 | 2 Bytes | 9.2 temperature difference (K) | CT |
| 202 | Zähler Datensatz 3 | D0 | 2 Bytes | 9.3 kelvin/hour (K/h) | CT |
| 202 | Zähler Datensatz 3 | D0 | 2 Bytes | 9.6 pressure (Pa) | CT |
| 202 | Zähler Datensatz 3 | D0 | 2 Bytes | 9.10 time (s) | CT |
| 202 | Zähler Datensatz 3 | D0 | 2 Bytes | 9.20 voltage (mV) | CT |
| 202 | Zähler Datensatz 3 | D0 | 2 Bytes | 9.21 current (mA) | CT |
| 202 | Zähler Datensatz 3 | D0 | 2 Bytes | 9.24 power (kW) | CT |
| 202 | Zähler Datensatz 3 | D0 | 2 Bytes | 9.25 volume flow (l/h) | CT |
| 202 | Zähler Datensatz 3 | D0 | 2 Bytes | 9.27 temperature (°F) | CT |
| 202 | Zähler Datensatz 3 | D0 | 3 Bytes | 10.1 time of day | CT |
| 202 | Zähler Datensatz 3 | D0 | 3 Bytes | 11.1 date | CT |
| 202 | Zähler Datensatz 3 | D0 | 4 Bytes | 12.1 counter pulses (unsigned) | CT |
| 202 | Zähler Datensatz 3 | D0 | 4 Bytes | 13.2 flow rate (m³/h) | CT |
| 202 | Zähler Datensatz 3 | D0 | 4 Bytes | 13.10 active energy (Wh) | CT |
| 202 | Zähler Datensatz 3 | D0 | 4 Bytes | 13.11 apparant energy (VAh) | CT |
| 202 | Zähler Datensatz 3 | D0 | 4 Bytes | 13.12 reactive energy (VARh) | CT |
| 202 | Zähler Datensatz 3 | D0 | 4 Bytes | 13.13 active energy (kWh) | CT |
| 202 | Zähler Datensatz 3 | D0 | 4 Bytes | 13.14 apparent energy (kVAh) | CT |
| 202 | Zähler Datensatz 3 | D0 | 4 Bytes | 13.15 reactive energy (kVARh) | CT |
| 202 | Zähler Datensatz 3 | D0 | 4 Bytes | 13.100 time lag (s) | CT |
| 202 | Zähler Datensatz 3 | D0 | 4 Bytes | 14.19 electric current (A) | CT |
| 202 | Zähler Datensatz 3 | D0 | 4 Bytes | 14.27 electric potential (V) | CT |
| 202 | Zähler Datensatz 3 | D0 | 4 Bytes | 14.31 energy (J) | CT |
| 202 | Zähler Datensatz 3 | D0 | 4 Bytes | 14.33 frequency (Hz) | CT |
| 202 | Zähler Datensatz 3 | D0 | 4 Bytes | 14.56 power (W) | CT |
| 202 | Zähler Datensatz 3 | D0 | 4 Bytes | 14.57 power factor (cos Φ) | CT |
| 202 | Zähler Datensatz 3 | D0 | 4 Bytes | 14.68 temperature (°C) | CT |
| 202 | Zähler Datensatz 3 | D0 | 4 Bytes | 14.76 volume (m³) | CT |
| 202 | Zähler Datensatz 3 | D0 | 8 Bytes | 29.10 active energy (Wh) | CT |
| 202 | Zähler Datensatz 3 | D0 | 8 Bytes | 29.11 apparant energy (VAh) | CT |
| 202 | Zähler Datensatz 3 | D0 | 8 Bytes | 29.12 reactive energy (VARh) | CT |
| 203 | Zähler Datensatz 4 | D0 | 1 Bit | 1.1 switch | CT |
| 203 | Zähler Datensatz 4 | D0 | 1 Bit | 1.3 enable | CT |
| 203 | Zähler Datensatz 4 | D0 | 1 Bit | 1.10 start/stop | CT |
| 203 | Zähler Datensatz 4 | D0 | 1 Bit | 1.15 reset | CT |
| 203 | Zähler Datensatz 4 | D0 | 2 Bytes | 7.5 time (s) | CT |
| 203 | Zähler Datensatz 4 | D0 | 2 Bytes | 7.7 time (h) | CT |
| 203 | Zähler Datensatz 4 | D0 | 2 Bytes | 9.1 temperature (°C) | CT |
| 203 | Zähler Datensatz 4 | D0 | 2 Bytes | 9.2 temperature difference (K) | CT |
| 203 | Zähler Datensatz 4 | D0 | 2 Bytes | 9.3 kelvin/hour (K/h) | CT |
| 203 | Zähler Datensatz 4 | D0 | 2 Bytes | 9.6 pressure (Pa) | CT |
| 203 | Zähler Datensatz 4 | D0 | 2 Bytes | 9.10 time (s) | CT |
| 203 | Zähler Datensatz 4 | D0 | 2 Bytes | 9.20 voltage (mV) | CT |
| 203 | Zähler Datensatz 4 | D0 | 2 Bytes | 9.21 current (mA) | CT |
| 203 | Zähler Datensatz 4 | D0 | 2 Bytes | 9.24 power (kW) | CT |
| 203 | Zähler Datensatz 4 | D0 | 2 Bytes | 9.25 volume flow (l/h) | CT |
| 203 | Zähler Datensatz 4 | D0 | 2 Bytes | 9.27 temperature (°F) | CT |
| 203 | Zähler Datensatz 4 | D0 | 3 Bytes | 10.1 time of day | CT |
| 203 | Zähler Datensatz 4 | D0 | 3 Bytes | 11.1 date | CT |
| 203 | Zähler Datensatz 4 | D0 | 4 Bytes | 12.1 counter pulses (unsigned) | CT |
| 203 | Zähler Datensatz 4 | D0 | 4 Bytes | 13.2 flow rate (m³/h) | CT |
| 203 | Zähler Datensatz 4 | D0 | 4 Bytes | 13.10 active energy (Wh) | CT |
| 203 | Zähler Datensatz 4 | D0 | 4 Bytes | 13.11 apparant energy (VAh) | CT |
| 203 | Zähler Datensatz 4 | D0 | 4 Bytes | 13.12 reactive energy (VARh) | CT |
| 203 | Zähler Datensatz 4 | D0 | 4 Bytes | 13.13 active energy (kWh) | CT |
| 203 | Zähler Datensatz 4 | D0 | 4 Bytes | 13.14 apparent energy (kVAh) | CT |
| 203 | Zähler Datensatz 4 | D0 | 4 Bytes | 13.15 reactive energy (kVARh) | CT |
| 203 | Zähler Datensatz 4 | D0 | 4 Bytes | 13.100 time lag (s) | CT |
| 203 | Zähler Datensatz 4 | D0 | 4 Bytes | 14.19 electric current (A) | CT |
| 203 | Zähler Datensatz 4 | D0 | 4 Bytes | 14.27 electric potential (V) | CT |
| 203 | Zähler Datensatz 4 | D0 | 4 Bytes | 14.31 energy (J) | CT |
| 203 | Zähler Datensatz 4 | D0 | 4 Bytes | 14.33 frequency (Hz) | CT |
| 203 | Zähler Datensatz 4 | D0 | 4 Bytes | 14.56 power (W) | CT |
| 203 | Zähler Datensatz 4 | D0 | 4 Bytes | 14.57 power factor (cos Φ) | CT |
| 203 | Zähler Datensatz 4 | D0 | 4 Bytes | 14.68 temperature (°C) | CT |
| 203 | Zähler Datensatz 4 | D0 | 4 Bytes | 14.76 volume (m³) | CT |
| 203 | Zähler Datensatz 4 | D0 | 8 Bytes | 29.10 active energy (Wh) | CT |
| 203 | Zähler Datensatz 4 | D0 | 8 Bytes | 29.11 apparant energy (VAh) | CT |
| 203 | Zähler Datensatz 4 | D0 | 8 Bytes | 29.12 reactive energy (VARh) | CT |
| 204 | Zähler Datensatz 5 | D0 | 1 Bit | 1.1 switch | CT |
| 204 | Zähler Datensatz 5 | D0 | 1 Bit | 1.3 enable | CT |
| 204 | Zähler Datensatz 5 | D0 | 1 Bit | 1.10 start/stop | CT |
| 204 | Zähler Datensatz 5 | D0 | 1 Bit | 1.15 reset | CT |
| 204 | Zähler Datensatz 5 | D0 | 2 Bytes | 7.5 time (s) | CT |
| 204 | Zähler Datensatz 5 | D0 | 2 Bytes | 7.7 time (h) | CT |
| 204 | Zähler Datensatz 5 | D0 | 2 Bytes | 9.1 temperature (°C) | CT |
| 204 | Zähler Datensatz 5 | D0 | 2 Bytes | 9.2 temperature difference (K) | CT |
| 204 | Zähler Datensatz 5 | D0 | 2 Bytes | 9.3 kelvin/hour (K/h) | CT |
| 204 | Zähler Datensatz 5 | D0 | 2 Bytes | 9.6 pressure (Pa) | CT |
| 204 | Zähler Datensatz 5 | D0 | 2 Bytes | 9.10 time (s) | CT |
| 204 | Zähler Datensatz 5 | D0 | 2 Bytes | 9.20 voltage (mV) | CT |
| 204 | Zähler Datensatz 5 | D0 | 2 Bytes | 9.21 current (mA) | CT |
| 204 | Zähler Datensatz 5 | D0 | 2 Bytes | 9.24 power (kW) | CT |
| 204 | Zähler Datensatz 5 | D0 | 2 Bytes | 9.25 volume flow (l/h) | CT |
| 204 | Zähler Datensatz 5 | D0 | 2 Bytes | 9.27 temperature (°F) | CT |
| 204 | Zähler Datensatz 5 | D0 | 3 Bytes | 10.1 time of day | CT |
| 204 | Zähler Datensatz 5 | D0 | 3 Bytes | 11.1 date | CT |
| 204 | Zähler Datensatz 5 | D0 | 4 Bytes | 12.1 counter pulses (unsigned) | CT |
| 204 | Zähler Datensatz 5 | D0 | 4 Bytes | 13.2 flow rate (m³/h) | CT |
| 204 | Zähler Datensatz 5 | D0 | 4 Bytes | 13.10 active energy (Wh) | CT |
| 204 | Zähler Datensatz 5 | D0 | 4 Bytes | 13.11 apparant energy (VAh) | CT |
| 204 | Zähler Datensatz 5 | D0 | 4 Bytes | 13.12 reactive energy (VARh) | CT |
| 204 | Zähler Datensatz 5 | D0 | 4 Bytes | 13.13 active energy (kWh) | CT |
| 204 | Zähler Datensatz 5 | D0 | 4 Bytes | 13.14 apparent energy (kVAh) | CT |
| 204 | Zähler Datensatz 5 | D0 | 4 Bytes | 13.15 reactive energy (kVARh) | CT |
| 204 | Zähler Datensatz 5 | D0 | 4 Bytes | 13.100 time lag (s) | CT |
| 204 | Zähler Datensatz 5 | D0 | 4 Bytes | 14.19 electric current (A) | CT |
| 204 | Zähler Datensatz 5 | D0 | 4 Bytes | 14.27 electric potential (V) | CT |
| 204 | Zähler Datensatz 5 | D0 | 4 Bytes | 14.31 energy (J) | CT |
| 204 | Zähler Datensatz 5 | D0 | 4 Bytes | 14.33 frequency (Hz) | CT |
| 204 | Zähler Datensatz 5 | D0 | 4 Bytes | 14.56 power (W) | CT |
| 204 | Zähler Datensatz 5 | D0 | 4 Bytes | 14.57 power factor (cos Φ) | CT |
| 204 | Zähler Datensatz 5 | D0 | 4 Bytes | 14.68 temperature (°C) | CT |
| 204 | Zähler Datensatz 5 | D0 | 4 Bytes | 14.76 volume (m³) | CT |
| 204 | Zähler Datensatz 5 | D0 | 8 Bytes | 29.10 active energy (Wh) | CT |
| 204 | Zähler Datensatz 5 | D0 | 8 Bytes | 29.11 apparant energy (VAh) | CT |
| 204 | Zähler Datensatz 5 | D0 | 8 Bytes | 29.12 reactive energy (VARh) | CT |
| 205 | Zähler Datensatz 6 | D0 | 1 Bit | 1.1 switch | CT |
| 205 | Zähler Datensatz 6 | D0 | 1 Bit | 1.3 enable | CT |
| 205 | Zähler Datensatz 6 | D0 | 1 Bit | 1.10 start/stop | CT |
| 205 | Zähler Datensatz 6 | D0 | 1 Bit | 1.15 reset | CT |
| 205 | Zähler Datensatz 6 | D0 | 2 Bytes | 7.5 time (s) | CT |
| 205 | Zähler Datensatz 6 | D0 | 2 Bytes | 7.7 time (h) | CT |
| 205 | Zähler Datensatz 6 | D0 | 2 Bytes | 9.1 temperature (°C) | CT |
| 205 | Zähler Datensatz 6 | D0 | 2 Bytes | 9.2 temperature difference (K) | CT |
| 205 | Zähler Datensatz 6 | D0 | 2 Bytes | 9.3 kelvin/hour (K/h) | CT |
| 205 | Zähler Datensatz 6 | D0 | 2 Bytes | 9.6 pressure (Pa) | CT |
| 205 | Zähler Datensatz 6 | D0 | 2 Bytes | 9.10 time (s) | CT |
| 205 | Zähler Datensatz 6 | D0 | 2 Bytes | 9.20 voltage (mV) | CT |
| 205 | Zähler Datensatz 6 | D0 | 2 Bytes | 9.21 current (mA) | CT |
| 205 | Zähler Datensatz 6 | D0 | 2 Bytes | 9.24 power (kW) | CT |
| 205 | Zähler Datensatz 6 | D0 | 2 Bytes | 9.25 volume flow (l/h) | CT |
| 205 | Zähler Datensatz 6 | D0 | 2 Bytes | 9.27 temperature (°F) | CT |
| 205 | Zähler Datensatz 6 | D0 | 3 Bytes | 10.1 time of day | CT |
| 205 | Zähler Datensatz 6 | D0 | 3 Bytes | 11.1 date | CT |
| 205 | Zähler Datensatz 6 | D0 | 4 Bytes | 12.1 counter pulses (unsigned) | CT |
| 205 | Zähler Datensatz 6 | D0 | 4 Bytes | 13.2 flow rate (m³/h) | CT |
| 205 | Zähler Datensatz 6 | D0 | 4 Bytes | 13.10 active energy (Wh) | CT |
| 205 | Zähler Datensatz 6 | D0 | 4 Bytes | 13.11 apparant energy (VAh) | CT |
| 205 | Zähler Datensatz 6 | D0 | 4 Bytes | 13.12 reactive energy (VARh) | CT |
| 205 | Zähler Datensatz 6 | D0 | 4 Bytes | 13.13 active energy (kWh) | CT |
| 205 | Zähler Datensatz 6 | D0 | 4 Bytes | 13.14 apparent energy (kVAh) | CT |
| 205 | Zähler Datensatz 6 | D0 | 4 Bytes | 13.15 reactive energy (kVARh) | CT |
| 205 | Zähler Datensatz 6 | D0 | 4 Bytes | 13.100 time lag (s) | CT |
| 205 | Zähler Datensatz 6 | D0 | 4 Bytes | 14.19 electric current (A) | CT |
| 205 | Zähler Datensatz 6 | D0 | 4 Bytes | 14.27 electric potential (V) | CT |
| 205 | Zähler Datensatz 6 | D0 | 4 Bytes | 14.31 energy (J) | CT |
| 205 | Zähler Datensatz 6 | D0 | 4 Bytes | 14.33 frequency (Hz) | CT |
| 205 | Zähler Datensatz 6 | D0 | 4 Bytes | 14.56 power (W) | CT |
| 205 | Zähler Datensatz 6 | D0 | 4 Bytes | 14.57 power factor (cos Φ) | CT |
| 205 | Zähler Datensatz 6 | D0 | 4 Bytes | 14.68 temperature (°C) | CT |
| 205 | Zähler Datensatz 6 | D0 | 4 Bytes | 14.76 volume (m³) | CT |
| 205 | Zähler Datensatz 6 | D0 | 8 Bytes | 29.10 active energy (Wh) | CT |
| 205 | Zähler Datensatz 6 | D0 | 8 Bytes | 29.11 apparant energy (VAh) | CT |
| 205 | Zähler Datensatz 6 | D0 | 8 Bytes | 29.12 reactive energy (VARh) | CT |
| 206 | Zähler Datensatz 7 | D0 | 1 Bit | 1.1 switch | CT |
| 206 | Zähler Datensatz 7 | D0 | 1 Bit | 1.3 enable | CT |
| 206 | Zähler Datensatz 7 | D0 | 1 Bit | 1.10 start/stop | CT |
| 206 | Zähler Datensatz 7 | D0 | 1 Bit | 1.15 reset | CT |
| 206 | Zähler Datensatz 7 | D0 | 2 Bytes | 7.5 time (s) | CT |
| 206 | Zähler Datensatz 7 | D0 | 2 Bytes | 7.7 time (h) | CT |
| 206 | Zähler Datensatz 7 | D0 | 2 Bytes | 9.1 temperature (°C) | CT |
| 206 | Zähler Datensatz 7 | D0 | 2 Bytes | 9.2 temperature difference (K) | CT |
| 206 | Zähler Datensatz 7 | D0 | 2 Bytes | 9.3 kelvin/hour (K/h) | CT |
| 206 | Zähler Datensatz 7 | D0 | 2 Bytes | 9.6 pressure (Pa) | CT |
| 206 | Zähler Datensatz 7 | D0 | 2 Bytes | 9.10 time (s) | CT |
| 206 | Zähler Datensatz 7 | D0 | 2 Bytes | 9.20 voltage (mV) | CT |
| 206 | Zähler Datensatz 7 | D0 | 2 Bytes | 9.21 current (mA) | CT |
| 206 | Zähler Datensatz 7 | D0 | 2 Bytes | 9.24 power (kW) | CT |
| 206 | Zähler Datensatz 7 | D0 | 2 Bytes | 9.25 volume flow (l/h) | CT |
| 206 | Zähler Datensatz 7 | D0 | 2 Bytes | 9.27 temperature (°F) | CT |
| 206 | Zähler Datensatz 7 | D0 | 3 Bytes | 10.1 time of day | CT |
| 206 | Zähler Datensatz 7 | D0 | 3 Bytes | 11.1 date | CT |
| 206 | Zähler Datensatz 7 | D0 | 4 Bytes | 12.1 counter pulses (unsigned) | CT |
| 206 | Zähler Datensatz 7 | D0 | 4 Bytes | 13.2 flow rate (m³/h) | CT |
| 206 | Zähler Datensatz 7 | D0 | 4 Bytes | 13.10 active energy (Wh) | CT |
| 206 | Zähler Datensatz 7 | D0 | 4 Bytes | 13.11 apparant energy (VAh) | CT |
| 206 | Zähler Datensatz 7 | D0 | 4 Bytes | 13.12 reactive energy (VARh) | CT |
| 206 | Zähler Datensatz 7 | D0 | 4 Bytes | 13.13 active energy (kWh) | CT |
| 206 | Zähler Datensatz 7 | D0 | 4 Bytes | 13.14 apparent energy (kVAh) | CT |
| 206 | Zähler Datensatz 7 | D0 | 4 Bytes | 13.15 reactive energy (kVARh) | CT |
| 206 | Zähler Datensatz 7 | D0 | 4 Bytes | 13.100 time lag (s) | CT |
| 206 | Zähler Datensatz 7 | D0 | 4 Bytes | 14.19 electric current (A) | CT |
| 206 | Zähler Datensatz 7 | D0 | 4 Bytes | 14.27 electric potential (V) | CT |
| 206 | Zähler Datensatz 7 | D0 | 4 Bytes | 14.31 energy (J) | CT |
| 206 | Zähler Datensatz 7 | D0 | 4 Bytes | 14.33 frequency (Hz) | CT |
| 206 | Zähler Datensatz 7 | D0 | 4 Bytes | 14.56 power (W) | CT |
| 206 | Zähler Datensatz 7 | D0 | 4 Bytes | 14.57 power factor (cos Φ) | CT |
| 206 | Zähler Datensatz 7 | D0 | 4 Bytes | 14.68 temperature (°C) | CT |
| 206 | Zähler Datensatz 7 | D0 | 4 Bytes | 14.76 volume (m³) | CT |
| 206 | Zähler Datensatz 7 | D0 | 8 Bytes | 29.10 active energy (Wh) | CT |
| 206 | Zähler Datensatz 7 | D0 | 8 Bytes | 29.11 apparant energy (VAh) | CT |
| 206 | Zähler Datensatz 7 | D0 | 8 Bytes | 29.12 reactive energy (VARh) | CT |
| 207 | Zähler Datensatz 8 | D0 | 1 Bit | 1.1 switch | CT |
| 207 | Zähler Datensatz 8 | D0 | 1 Bit | 1.3 enable | CT |
| 207 | Zähler Datensatz 8 | D0 | 1 Bit | 1.10 start/stop | CT |
| 207 | Zähler Datensatz 8 | D0 | 1 Bit | 1.15 reset | CT |
| 207 | Zähler Datensatz 8 | D0 | 2 Bytes | 7.5 time (s) | CT |
| 207 | Zähler Datensatz 8 | D0 | 2 Bytes | 7.7 time (h) | CT |
| 207 | Zähler Datensatz 8 | D0 | 2 Bytes | 9.1 temperature (°C) | CT |
| 207 | Zähler Datensatz 8 | D0 | 2 Bytes | 9.2 temperature difference (K) | CT |
| 207 | Zähler Datensatz 8 | D0 | 2 Bytes | 9.3 kelvin/hour (K/h) | CT |
| 207 | Zähler Datensatz 8 | D0 | 2 Bytes | 9.6 pressure (Pa) | CT |
| 207 | Zähler Datensatz 8 | D0 | 2 Bytes | 9.10 time (s) | CT |
| 207 | Zähler Datensatz 8 | D0 | 2 Bytes | 9.20 voltage (mV) | CT |
| 207 | Zähler Datensatz 8 | D0 | 2 Bytes | 9.21 current (mA) | CT |
| 207 | Zähler Datensatz 8 | D0 | 2 Bytes | 9.24 power (kW) | CT |
| 207 | Zähler Datensatz 8 | D0 | 2 Bytes | 9.25 volume flow (l/h) | CT |
| 207 | Zähler Datensatz 8 | D0 | 2 Bytes | 9.27 temperature (°F) | CT |
| 207 | Zähler Datensatz 8 | D0 | 3 Bytes | 10.1 time of day | CT |
| 207 | Zähler Datensatz 8 | D0 | 3 Bytes | 11.1 date | CT |
| 207 | Zähler Datensatz 8 | D0 | 4 Bytes | 12.1 counter pulses (unsigned) | CT |
| 207 | Zähler Datensatz 8 | D0 | 4 Bytes | 13.2 flow rate (m³/h) | CT |
| 207 | Zähler Datensatz 8 | D0 | 4 Bytes | 13.10 active energy (Wh) | CT |
| 207 | Zähler Datensatz 8 | D0 | 4 Bytes | 13.11 apparant energy (VAh) | CT |
| 207 | Zähler Datensatz 8 | D0 | 4 Bytes | 13.12 reactive energy (VARh) | CT |
| 207 | Zähler Datensatz 8 | D0 | 4 Bytes | 13.13 active energy (kWh) | CT |
| 207 | Zähler Datensatz 8 | D0 | 4 Bytes | 13.14 apparent energy (kVAh) | CT |
| 207 | Zähler Datensatz 8 | D0 | 4 Bytes | 13.15 reactive energy (kVARh) | CT |
| 207 | Zähler Datensatz 8 | D0 | 4 Bytes | 13.100 time lag (s) | CT |
| 207 | Zähler Datensatz 8 | D0 | 4 Bytes | 14.19 electric current (A) | CT |
| 207 | Zähler Datensatz 8 | D0 | 4 Bytes | 14.27 electric potential (V) | CT |
| 207 | Zähler Datensatz 8 | D0 | 4 Bytes | 14.31 energy (J) | CT |
| 207 | Zähler Datensatz 8 | D0 | 4 Bytes | 14.33 frequency (Hz) | CT |
| 207 | Zähler Datensatz 8 | D0 | 4 Bytes | 14.56 power (W) | CT |
| 207 | Zähler Datensatz 8 | D0 | 4 Bytes | 14.57 power factor (cos Φ) | CT |
| 207 | Zähler Datensatz 8 | D0 | 4 Bytes | 14.68 temperature (°C) | CT |
| 207 | Zähler Datensatz 8 | D0 | 4 Bytes | 14.76 volume (m³) | CT |
| 207 | Zähler Datensatz 8 | D0 | 8 Bytes | 29.10 active energy (Wh) | CT |
| 207 | Zähler Datensatz 8 | D0 | 8 Bytes | 29.11 apparant energy (VAh) | CT |
| 207 | Zähler Datensatz 8 | D0 | 8 Bytes | 29.12 reactive energy (VARh) | CT |
| 208 | Zähler Datensatz 9 | D0 | 1 Bit | 1.1 switch | CT |
| 208 | Zähler Datensatz 9 | D0 | 1 Bit | 1.3 enable | CT |
| 208 | Zähler Datensatz 9 | D0 | 1 Bit | 1.10 start/stop | CT |
| 208 | Zähler Datensatz 9 | D0 | 1 Bit | 1.15 reset | CT |
| 208 | Zähler Datensatz 9 | D0 | 2 Bytes | 7.5 time (s) | CT |
| 208 | Zähler Datensatz 9 | D0 | 2 Bytes | 7.7 time (h) | CT |
| 208 | Zähler Datensatz 9 | D0 | 2 Bytes | 9.1 temperature (°C) | CT |
| 208 | Zähler Datensatz 9 | D0 | 2 Bytes | 9.2 temperature difference (K) | CT |
| 208 | Zähler Datensatz 9 | D0 | 2 Bytes | 9.3 kelvin/hour (K/h) | CT |
| 208 | Zähler Datensatz 9 | D0 | 2 Bytes | 9.6 pressure (Pa) | CT |
| 208 | Zähler Datensatz 9 | D0 | 2 Bytes | 9.10 time (s) | CT |
| 208 | Zähler Datensatz 9 | D0 | 2 Bytes | 9.20 voltage (mV) | CT |
| 208 | Zähler Datensatz 9 | D0 | 2 Bytes | 9.21 current (mA) | CT |
| 208 | Zähler Datensatz 9 | D0 | 2 Bytes | 9.24 power (kW) | CT |
| 208 | Zähler Datensatz 9 | D0 | 2 Bytes | 9.25 volume flow (l/h) | CT |
| 208 | Zähler Datensatz 9 | D0 | 2 Bytes | 9.27 temperature (°F) | CT |
| 208 | Zähler Datensatz 9 | D0 | 3 Bytes | 10.1 time of day | CT |
| 208 | Zähler Datensatz 9 | D0 | 3 Bytes | 11.1 date | CT |
| 208 | Zähler Datensatz 9 | D0 | 4 Bytes | 12.1 counter pulses (unsigned) | CT |
| 208 | Zähler Datensatz 9 | D0 | 4 Bytes | 13.2 flow rate (m³/h) | CT |
| 208 | Zähler Datensatz 9 | D0 | 4 Bytes | 13.10 active energy (Wh) | CT |
| 208 | Zähler Datensatz 9 | D0 | 4 Bytes | 13.11 apparant energy (VAh) | CT |
| 208 | Zähler Datensatz 9 | D0 | 4 Bytes | 13.12 reactive energy (VARh) | CT |
| 208 | Zähler Datensatz 9 | D0 | 4 Bytes | 13.13 active energy (kWh) | CT |
| 208 | Zähler Datensatz 9 | D0 | 4 Bytes | 13.14 apparent energy (kVAh) | CT |
| 208 | Zähler Datensatz 9 | D0 | 4 Bytes | 13.15 reactive energy (kVARh) | CT |
| 208 | Zähler Datensatz 9 | D0 | 4 Bytes | 13.100 time lag (s) | CT |
| 208 | Zähler Datensatz 9 | D0 | 4 Bytes | 14.19 electric current (A) | CT |
| 208 | Zähler Datensatz 9 | D0 | 4 Bytes | 14.27 electric potential (V) | CT |
| 208 | Zähler Datensatz 9 | D0 | 4 Bytes | 14.31 energy (J) | CT |
| 208 | Zähler Datensatz 9 | D0 | 4 Bytes | 14.33 frequency (Hz) | CT |
| 208 | Zähler Datensatz 9 | D0 | 4 Bytes | 14.56 power (W) | CT |
| 208 | Zähler Datensatz 9 | D0 | 4 Bytes | 14.57 power factor (cos Φ) | CT |
| 208 | Zähler Datensatz 9 | D0 | 4 Bytes | 14.68 temperature (°C) | CT |
| 208 | Zähler Datensatz 9 | D0 | 4 Bytes | 14.76 volume (m³) | CT |
| 208 | Zähler Datensatz 9 | D0 | 8 Bytes | 29.10 active energy (Wh) | CT |
| 208 | Zähler Datensatz 9 | D0 | 8 Bytes | 29.11 apparant energy (VAh) | CT |
| 208 | Zähler Datensatz 9 | D0 | 8 Bytes | 29.12 reactive energy (VARh) | CT |
| 209 | Zähler Datensatz 10 | D0 | 1 Bit | 1.1 switch | CT |
| 209 | Zähler Datensatz 10 | D0 | 1 Bit | 1.3 enable | CT |
| 209 | Zähler Datensatz 10 | D0 | 1 Bit | 1.10 start/stop | CT |
| 209 | Zähler Datensatz 10 | D0 | 1 Bit | 1.15 reset | CT |
| 209 | Zähler Datensatz 10 | D0 | 2 Bytes | 7.5 time (s) | CT |
| 209 | Zähler Datensatz 10 | D0 | 2 Bytes | 7.7 time (h) | CT |
| 209 | Zähler Datensatz 10 | D0 | 2 Bytes | 9.1 temperature (°C) | CT |
| 209 | Zähler Datensatz 10 | D0 | 2 Bytes | 9.2 temperature difference (K) | CT |
| 209 | Zähler Datensatz 10 | D0 | 2 Bytes | 9.3 kelvin/hour (K/h) | CT |
| 209 | Zähler Datensatz 10 | D0 | 2 Bytes | 9.6 pressure (Pa) | CT |
| 209 | Zähler Datensatz 10 | D0 | 2 Bytes | 9.10 time (s) | CT |
| 209 | Zähler Datensatz 10 | D0 | 2 Bytes | 9.20 voltage (mV) | CT |
| 209 | Zähler Datensatz 10 | D0 | 2 Bytes | 9.21 current (mA) | CT |
| 209 | Zähler Datensatz 10 | D0 | 2 Bytes | 9.24 power (kW) | CT |
| 209 | Zähler Datensatz 10 | D0 | 2 Bytes | 9.25 volume flow (l/h) | CT |
| 209 | Zähler Datensatz 10 | D0 | 2 Bytes | 9.27 temperature (°F) | CT |
| 209 | Zähler Datensatz 10 | D0 | 3 Bytes | 10.1 time of day | CT |
| 209 | Zähler Datensatz 10 | D0 | 3 Bytes | 11.1 date | CT |
| 209 | Zähler Datensatz 10 | D0 | 4 Bytes | 12.1 counter pulses (unsigned) | CT |
| 209 | Zähler Datensatz 10 | D0 | 4 Bytes | 13.2 flow rate (m³/h) | CT |
| 209 | Zähler Datensatz 10 | D0 | 4 Bytes | 13.10 active energy (Wh) | CT |
| 209 | Zähler Datensatz 10 | D0 | 4 Bytes | 13.11 apparant energy (VAh) | CT |
| 209 | Zähler Datensatz 10 | D0 | 4 Bytes | 13.12 reactive energy (VARh) | CT |
| 209 | Zähler Datensatz 10 | D0 | 4 Bytes | 13.13 active energy (kWh) | CT |
| 209 | Zähler Datensatz 10 | D0 | 4 Bytes | 13.14 apparent energy (kVAh) | CT |
| 209 | Zähler Datensatz 10 | D0 | 4 Bytes | 13.15 reactive energy (kVARh) | CT |
| 209 | Zähler Datensatz 10 | D0 | 4 Bytes | 13.100 time lag (s) | CT |
| 209 | Zähler Datensatz 10 | D0 | 4 Bytes | 14.19 electric current (A) | CT |
| 209 | Zähler Datensatz 10 | D0 | 4 Bytes | 14.27 electric potential (V) | CT |
| 209 | Zähler Datensatz 10 | D0 | 4 Bytes | 14.31 energy (J) | CT |
| 209 | Zähler Datensatz 10 | D0 | 4 Bytes | 14.33 frequency (Hz) | CT |
| 209 | Zähler Datensatz 10 | D0 | 4 Bytes | 14.56 power (W) | CT |
| 209 | Zähler Datensatz 10 | D0 | 4 Bytes | 14.57 power factor (cos Φ) | CT |
| 209 | Zähler Datensatz 10 | D0 | 4 Bytes | 14.68 temperature (°C) | CT |
| 209 | Zähler Datensatz 10 | D0 | 4 Bytes | 14.76 volume (m³) | CT |
| 209 | Zähler Datensatz 10 | D0 | 8 Bytes | 29.10 active energy (Wh) | CT |
| 209 | Zähler Datensatz 10 | D0 | 8 Bytes | 29.11 apparant energy (VAh) | CT |
| 209 | Zähler Datensatz 10 | D0 | 8 Bytes | 29.12 reactive energy (VARh) | CT |
| 210 | Zähler Datensatz 11 | D0 | 1 Bit | 1.1 switch | CT |
| 210 | Zähler Datensatz 11 | D0 | 1 Bit | 1.3 enable | CT |
| 210 | Zähler Datensatz 11 | D0 | 1 Bit | 1.10 start/stop | CT |
| 210 | Zähler Datensatz 11 | D0 | 1 Bit | 1.15 reset | CT |
| 210 | Zähler Datensatz 11 | D0 | 2 Bytes | 7.5 time (s) | CT |
| 210 | Zähler Datensatz 11 | D0 | 2 Bytes | 7.7 time (h) | CT |
| 210 | Zähler Datensatz 11 | D0 | 2 Bytes | 9.1 temperature (°C) | CT |
| 210 | Zähler Datensatz 11 | D0 | 2 Bytes | 9.2 temperature difference (K) | CT |
| 210 | Zähler Datensatz 11 | D0 | 2 Bytes | 9.3 kelvin/hour (K/h) | CT |
| 210 | Zähler Datensatz 11 | D0 | 2 Bytes | 9.6 pressure (Pa) | CT |
| 210 | Zähler Datensatz 11 | D0 | 2 Bytes | 9.10 time (s) | CT |
| 210 | Zähler Datensatz 11 | D0 | 2 Bytes | 9.20 voltage (mV) | CT |
| 210 | Zähler Datensatz 11 | D0 | 2 Bytes | 9.21 current (mA) | CT |
| 210 | Zähler Datensatz 11 | D0 | 2 Bytes | 9.24 power (kW) | CT |
| 210 | Zähler Datensatz 11 | D0 | 2 Bytes | 9.25 volume flow (l/h) | CT |
| 210 | Zähler Datensatz 11 | D0 | 2 Bytes | 9.27 temperature (°F) | CT |
| 210 | Zähler Datensatz 11 | D0 | 3 Bytes | 10.1 time of day | CT |
| 210 | Zähler Datensatz 11 | D0 | 3 Bytes | 11.1 date | CT |
| 210 | Zähler Datensatz 11 | D0 | 4 Bytes | 12.1 counter pulses (unsigned) | CT |
| 210 | Zähler Datensatz 11 | D0 | 4 Bytes | 13.2 flow rate (m³/h) | CT |
| 210 | Zähler Datensatz 11 | D0 | 4 Bytes | 13.10 active energy (Wh) | CT |
| 210 | Zähler Datensatz 11 | D0 | 4 Bytes | 13.11 apparant energy (VAh) | CT |
| 210 | Zähler Datensatz 11 | D0 | 4 Bytes | 13.12 reactive energy (VARh) | CT |
| 210 | Zähler Datensatz 11 | D0 | 4 Bytes | 13.13 active energy (kWh) | CT |
| 210 | Zähler Datensatz 11 | D0 | 4 Bytes | 13.14 apparent energy (kVAh) | CT |
| 210 | Zähler Datensatz 11 | D0 | 4 Bytes | 13.15 reactive energy (kVARh) | CT |
| 210 | Zähler Datensatz 11 | D0 | 4 Bytes | 13.100 time lag (s) | CT |
| 210 | Zähler Datensatz 11 | D0 | 4 Bytes | 14.19 electric current (A) | CT |
| 210 | Zähler Datensatz 11 | D0 | 4 Bytes | 14.27 electric potential (V) | CT |
| 210 | Zähler Datensatz 11 | D0 | 4 Bytes | 14.31 energy (J) | CT |
| 210 | Zähler Datensatz 11 | D0 | 4 Bytes | 14.33 frequency (Hz) | CT |
| 210 | Zähler Datensatz 11 | D0 | 4 Bytes | 14.56 power (W) | CT |
| 210 | Zähler Datensatz 11 | D0 | 4 Bytes | 14.57 power factor (cos Φ) | CT |
| 210 | Zähler Datensatz 11 | D0 | 4 Bytes | 14.68 temperature (°C) | CT |
| 210 | Zähler Datensatz 11 | D0 | 4 Bytes | 14.76 volume (m³) | CT |
| 210 | Zähler Datensatz 11 | D0 | 8 Bytes | 29.10 active energy (Wh) | CT |
| 210 | Zähler Datensatz 11 | D0 | 8 Bytes | 29.11 apparant energy (VAh) | CT |
| 210 | Zähler Datensatz 11 | D0 | 8 Bytes | 29.12 reactive energy (VARh) | CT |
| 211 | Zähler Datensatz 12 | D0 | 1 Bit | 1.1 switch | CT |
| 211 | Zähler Datensatz 12 | D0 | 1 Bit | 1.3 enable | CT |
| 211 | Zähler Datensatz 12 | D0 | 1 Bit | 1.10 start/stop | CT |
| 211 | Zähler Datensatz 12 | D0 | 1 Bit | 1.15 reset | CT |
| 211 | Zähler Datensatz 12 | D0 | 2 Bytes | 7.5 time (s) | CT |
| 211 | Zähler Datensatz 12 | D0 | 2 Bytes | 7.7 time (h) | CT |
| 211 | Zähler Datensatz 12 | D0 | 2 Bytes | 9.1 temperature (°C) | CT |
| 211 | Zähler Datensatz 12 | D0 | 2 Bytes | 9.2 temperature difference (K) | CT |
| 211 | Zähler Datensatz 12 | D0 | 2 Bytes | 9.3 kelvin/hour (K/h) | CT |
| 211 | Zähler Datensatz 12 | D0 | 2 Bytes | 9.6 pressure (Pa) | CT |
| 211 | Zähler Datensatz 12 | D0 | 2 Bytes | 9.10 time (s) | CT |
| 211 | Zähler Datensatz 12 | D0 | 2 Bytes | 9.20 voltage (mV) | CT |
| 211 | Zähler Datensatz 12 | D0 | 2 Bytes | 9.21 current (mA) | CT |
| 211 | Zähler Datensatz 12 | D0 | 2 Bytes | 9.24 power (kW) | CT |
| 211 | Zähler Datensatz 12 | D0 | 2 Bytes | 9.25 volume flow (l/h) | CT |
| 211 | Zähler Datensatz 12 | D0 | 2 Bytes | 9.27 temperature (°F) | CT |
| 211 | Zähler Datensatz 12 | D0 | 3 Bytes | 10.1 time of day | CT |
| 211 | Zähler Datensatz 12 | D0 | 3 Bytes | 11.1 date | CT |
| 211 | Zähler Datensatz 12 | D0 | 4 Bytes | 12.1 counter pulses (unsigned) | CT |
| 211 | Zähler Datensatz 12 | D0 | 4 Bytes | 13.2 flow rate (m³/h) | CT |
| 211 | Zähler Datensatz 12 | D0 | 4 Bytes | 13.10 active energy (Wh) | CT |
| 211 | Zähler Datensatz 12 | D0 | 4 Bytes | 13.11 apparant energy (VAh) | CT |
| 211 | Zähler Datensatz 12 | D0 | 4 Bytes | 13.12 reactive energy (VARh) | CT |
| 211 | Zähler Datensatz 12 | D0 | 4 Bytes | 13.13 active energy (kWh) | CT |
| 211 | Zähler Datensatz 12 | D0 | 4 Bytes | 13.14 apparent energy (kVAh) | CT |
| 211 | Zähler Datensatz 12 | D0 | 4 Bytes | 13.15 reactive energy (kVARh) | CT |
| 211 | Zähler Datensatz 12 | D0 | 4 Bytes | 13.100 time lag (s) | CT |
| 211 | Zähler Datensatz 12 | D0 | 4 Bytes | 14.19 electric current (A) | CT |
| 211 | Zähler Datensatz 12 | D0 | 4 Bytes | 14.27 electric potential (V) | CT |
| 211 | Zähler Datensatz 12 | D0 | 4 Bytes | 14.31 energy (J) | CT |
| 211 | Zähler Datensatz 12 | D0 | 4 Bytes | 14.33 frequency (Hz) | CT |
| 211 | Zähler Datensatz 12 | D0 | 4 Bytes | 14.56 power (W) | CT |
| 211 | Zähler Datensatz 12 | D0 | 4 Bytes | 14.57 power factor (cos Φ) | CT |
| 211 | Zähler Datensatz 12 | D0 | 4 Bytes | 14.68 temperature (°C) | CT |
| 211 | Zähler Datensatz 12 | D0 | 4 Bytes | 14.76 volume (m³) | CT |
| 211 | Zähler Datensatz 12 | D0 | 8 Bytes | 29.10 active energy (Wh) | CT |
| 211 | Zähler Datensatz 12 | D0 | 8 Bytes | 29.11 apparant energy (VAh) | CT |
| 211 | Zähler Datensatz 12 | D0 | 8 Bytes | 29.12 reactive energy (VARh) | CT |
| 212 | Zähler Datensatz 13 | D0 | 1 Bit | 1.1 switch | CT |
| 212 | Zähler Datensatz 13 | D0 | 1 Bit | 1.3 enable | CT |
| 212 | Zähler Datensatz 13 | D0 | 1 Bit | 1.10 start/stop | CT |
| 212 | Zähler Datensatz 13 | D0 | 1 Bit | 1.15 reset | CT |
| 212 | Zähler Datensatz 13 | D0 | 2 Bytes | 7.5 time (s) | CT |
| 212 | Zähler Datensatz 13 | D0 | 2 Bytes | 7.7 time (h) | CT |
| 212 | Zähler Datensatz 13 | D0 | 2 Bytes | 9.1 temperature (°C) | CT |
| 212 | Zähler Datensatz 13 | D0 | 2 Bytes | 9.2 temperature difference (K) | CT |
| 212 | Zähler Datensatz 13 | D0 | 2 Bytes | 9.3 kelvin/hour (K/h) | CT |
| 212 | Zähler Datensatz 13 | D0 | 2 Bytes | 9.6 pressure (Pa) | CT |
| 212 | Zähler Datensatz 13 | D0 | 2 Bytes | 9.10 time (s) | CT |
| 212 | Zähler Datensatz 13 | D0 | 2 Bytes | 9.20 voltage (mV) | CT |
| 212 | Zähler Datensatz 13 | D0 | 2 Bytes | 9.21 current (mA) | CT |
| 212 | Zähler Datensatz 13 | D0 | 2 Bytes | 9.24 power (kW) | CT |
| 212 | Zähler Datensatz 13 | D0 | 2 Bytes | 9.25 volume flow (l/h) | CT |
| 212 | Zähler Datensatz 13 | D0 | 2 Bytes | 9.27 temperature (°F) | CT |
| 212 | Zähler Datensatz 13 | D0 | 3 Bytes | 10.1 time of day | CT |
| 212 | Zähler Datensatz 13 | D0 | 3 Bytes | 11.1 date | CT |
| 212 | Zähler Datensatz 13 | D0 | 4 Bytes | 12.1 counter pulses (unsigned) | CT |
| 212 | Zähler Datensatz 13 | D0 | 4 Bytes | 13.2 flow rate (m³/h) | CT |
| 212 | Zähler Datensatz 13 | D0 | 4 Bytes | 13.10 active energy (Wh) | CT |
| 212 | Zähler Datensatz 13 | D0 | 4 Bytes | 13.11 apparant energy (VAh) | CT |
| 212 | Zähler Datensatz 13 | D0 | 4 Bytes | 13.12 reactive energy (VARh) | CT |
| 212 | Zähler Datensatz 13 | D0 | 4 Bytes | 13.13 active energy (kWh) | CT |
| 212 | Zähler Datensatz 13 | D0 | 4 Bytes | 13.14 apparent energy (kVAh) | CT |
| 212 | Zähler Datensatz 13 | D0 | 4 Bytes | 13.15 reactive energy (kVARh) | CT |
| 212 | Zähler Datensatz 13 | D0 | 4 Bytes | 13.100 time lag (s) | CT |
| 212 | Zähler Datensatz 13 | D0 | 4 Bytes | 14.19 electric current (A) | CT |
| 212 | Zähler Datensatz 13 | D0 | 4 Bytes | 14.27 electric potential (V) | CT |
| 212 | Zähler Datensatz 13 | D0 | 4 Bytes | 14.31 energy (J) | CT |
| 212 | Zähler Datensatz 13 | D0 | 4 Bytes | 14.33 frequency (Hz) | CT |
| 212 | Zähler Datensatz 13 | D0 | 4 Bytes | 14.56 power (W) | CT |
| 212 | Zähler Datensatz 13 | D0 | 4 Bytes | 14.57 power factor (cos Φ) | CT |
| 212 | Zähler Datensatz 13 | D0 | 4 Bytes | 14.68 temperature (°C) | CT |
| 212 | Zähler Datensatz 13 | D0 | 4 Bytes | 14.76 volume (m³) | CT |
| 212 | Zähler Datensatz 13 | D0 | 8 Bytes | 29.10 active energy (Wh) | CT |
| 212 | Zähler Datensatz 13 | D0 | 8 Bytes | 29.11 apparant energy (VAh) | CT |
| 212 | Zähler Datensatz 13 | D0 | 8 Bytes | 29.12 reactive energy (VARh) | CT |
| 213 | Zähler Datensatz 14 | D0 | 1 Bit | 1.1 switch | CT |
| 213 | Zähler Datensatz 14 | D0 | 1 Bit | 1.3 enable | CT |
| 213 | Zähler Datensatz 14 | D0 | 1 Bit | 1.10 start/stop | CT |
| 213 | Zähler Datensatz 14 | D0 | 1 Bit | 1.15 reset | CT |
| 213 | Zähler Datensatz 14 | D0 | 2 Bytes | 7.5 time (s) | CT |
| 213 | Zähler Datensatz 14 | D0 | 2 Bytes | 7.7 time (h) | CT |
| 213 | Zähler Datensatz 14 | D0 | 2 Bytes | 9.1 temperature (°C) | CT |
| 213 | Zähler Datensatz 14 | D0 | 2 Bytes | 9.2 temperature difference (K) | CT |
| 213 | Zähler Datensatz 14 | D0 | 2 Bytes | 9.3 kelvin/hour (K/h) | CT |
| 213 | Zähler Datensatz 14 | D0 | 2 Bytes | 9.6 pressure (Pa) | CT |
| 213 | Zähler Datensatz 14 | D0 | 2 Bytes | 9.10 time (s) | CT |
| 213 | Zähler Datensatz 14 | D0 | 2 Bytes | 9.20 voltage (mV) | CT |
| 213 | Zähler Datensatz 14 | D0 | 2 Bytes | 9.21 current (mA) | CT |
| 213 | Zähler Datensatz 14 | D0 | 2 Bytes | 9.24 power (kW) | CT |
| 213 | Zähler Datensatz 14 | D0 | 2 Bytes | 9.25 volume flow (l/h) | CT |
| 213 | Zähler Datensatz 14 | D0 | 2 Bytes | 9.27 temperature (°F) | CT |
| 213 | Zähler Datensatz 14 | D0 | 3 Bytes | 10.1 time of day | CT |
| 213 | Zähler Datensatz 14 | D0 | 3 Bytes | 11.1 date | CT |
| 213 | Zähler Datensatz 14 | D0 | 4 Bytes | 12.1 counter pulses (unsigned) | CT |
| 213 | Zähler Datensatz 14 | D0 | 4 Bytes | 13.2 flow rate (m³/h) | CT |
| 213 | Zähler Datensatz 14 | D0 | 4 Bytes | 13.10 active energy (Wh) | CT |
| 213 | Zähler Datensatz 14 | D0 | 4 Bytes | 13.11 apparant energy (VAh) | CT |
| 213 | Zähler Datensatz 14 | D0 | 4 Bytes | 13.12 reactive energy (VARh) | CT |
| 213 | Zähler Datensatz 14 | D0 | 4 Bytes | 13.13 active energy (kWh) | CT |
| 213 | Zähler Datensatz 14 | D0 | 4 Bytes | 13.14 apparent energy (kVAh) | CT |
| 213 | Zähler Datensatz 14 | D0 | 4 Bytes | 13.15 reactive energy (kVARh) | CT |
| 213 | Zähler Datensatz 14 | D0 | 4 Bytes | 13.100 time lag (s) | CT |
| 213 | Zähler Datensatz 14 | D0 | 4 Bytes | 14.19 electric current (A) | CT |
| 213 | Zähler Datensatz 14 | D0 | 4 Bytes | 14.27 electric potential (V) | CT |
| 213 | Zähler Datensatz 14 | D0 | 4 Bytes | 14.31 energy (J) | CT |
| 213 | Zähler Datensatz 14 | D0 | 4 Bytes | 14.33 frequency (Hz) | CT |
| 213 | Zähler Datensatz 14 | D0 | 4 Bytes | 14.56 power (W) | CT |
| 213 | Zähler Datensatz 14 | D0 | 4 Bytes | 14.57 power factor (cos Φ) | CT |
| 213 | Zähler Datensatz 14 | D0 | 4 Bytes | 14.68 temperature (°C) | CT |
| 213 | Zähler Datensatz 14 | D0 | 4 Bytes | 14.76 volume (m³) | CT |
| 213 | Zähler Datensatz 14 | D0 | 8 Bytes | 29.10 active energy (Wh) | CT |
| 213 | Zähler Datensatz 14 | D0 | 8 Bytes | 29.11 apparant energy (VAh) | CT |
| 213 | Zähler Datensatz 14 | D0 | 8 Bytes | 29.12 reactive energy (VARh) | CT |
| 214 | Zähler Datensatz 15 | D0 | 1 Bit | 1.1 switch | CT |
| 214 | Zähler Datensatz 15 | D0 | 1 Bit | 1.3 enable | CT |
| 214 | Zähler Datensatz 15 | D0 | 1 Bit | 1.10 start/stop | CT |
| 214 | Zähler Datensatz 15 | D0 | 1 Bit | 1.15 reset | CT |
| 214 | Zähler Datensatz 15 | D0 | 2 Bytes | 7.5 time (s) | CT |
| 214 | Zähler Datensatz 15 | D0 | 2 Bytes | 7.7 time (h) | CT |
| 214 | Zähler Datensatz 15 | D0 | 2 Bytes | 9.1 temperature (°C) | CT |
| 214 | Zähler Datensatz 15 | D0 | 2 Bytes | 9.2 temperature difference (K) | CT |
| 214 | Zähler Datensatz 15 | D0 | 2 Bytes | 9.3 kelvin/hour (K/h) | CT |
| 214 | Zähler Datensatz 15 | D0 | 2 Bytes | 9.6 pressure (Pa) | CT |
| 214 | Zähler Datensatz 15 | D0 | 2 Bytes | 9.10 time (s) | CT |
| 214 | Zähler Datensatz 15 | D0 | 2 Bytes | 9.20 voltage (mV) | CT |
| 214 | Zähler Datensatz 15 | D0 | 2 Bytes | 9.21 current (mA) | CT |
| 214 | Zähler Datensatz 15 | D0 | 2 Bytes | 9.24 power (kW) | CT |
| 214 | Zähler Datensatz 15 | D0 | 2 Bytes | 9.25 volume flow (l/h) | CT |
| 214 | Zähler Datensatz 15 | D0 | 2 Bytes | 9.27 temperature (°F) | CT |
| 214 | Zähler Datensatz 15 | D0 | 3 Bytes | 10.1 time of day | CT |
| 214 | Zähler Datensatz 15 | D0 | 3 Bytes | 11.1 date | CT |
| 214 | Zähler Datensatz 15 | D0 | 4 Bytes | 12.1 counter pulses (unsigned) | CT |
| 214 | Zähler Datensatz 15 | D0 | 4 Bytes | 13.2 flow rate (m³/h) | CT |
| 214 | Zähler Datensatz 15 | D0 | 4 Bytes | 13.10 active energy (Wh) | CT |
| 214 | Zähler Datensatz 15 | D0 | 4 Bytes | 13.11 apparant energy (VAh) | CT |
| 214 | Zähler Datensatz 15 | D0 | 4 Bytes | 13.12 reactive energy (VARh) | CT |
| 214 | Zähler Datensatz 15 | D0 | 4 Bytes | 13.13 active energy (kWh) | CT |
| 214 | Zähler Datensatz 15 | D0 | 4 Bytes | 13.14 apparent energy (kVAh) | CT |
| 214 | Zähler Datensatz 15 | D0 | 4 Bytes | 13.15 reactive energy (kVARh) | CT |
| 214 | Zähler Datensatz 15 | D0 | 4 Bytes | 13.100 time lag (s) | CT |
| 214 | Zähler Datensatz 15 | D0 | 4 Bytes | 14.19 electric current (A) | CT |
| 214 | Zähler Datensatz 15 | D0 | 4 Bytes | 14.27 electric potential (V) | CT |
| 214 | Zähler Datensatz 15 | D0 | 4 Bytes | 14.31 energy (J) | CT |
| 214 | Zähler Datensatz 15 | D0 | 4 Bytes | 14.33 frequency (Hz) | CT |
| 214 | Zähler Datensatz 15 | D0 | 4 Bytes | 14.56 power (W) | CT |
| 214 | Zähler Datensatz 15 | D0 | 4 Bytes | 14.57 power factor (cos Φ) | CT |
| 214 | Zähler Datensatz 15 | D0 | 4 Bytes | 14.68 temperature (°C) | CT |
| 214 | Zähler Datensatz 15 | D0 | 4 Bytes | 14.76 volume (m³) | CT |
| 214 | Zähler Datensatz 15 | D0 | 8 Bytes | 29.10 active energy (Wh) | CT |
| 214 | Zähler Datensatz 15 | D0 | 8 Bytes | 29.11 apparant energy (VAh) | CT |
| 214 | Zähler Datensatz 15 | D0 | 8 Bytes | 29.12 reactive energy (VARh) | CT |
| 215 | Zähler Datensatz 16 | D0 | 1 Bit | 1.1 switch | CT |
| 215 | Zähler Datensatz 16 | D0 | 1 Bit | 1.3 enable | CT |
| 215 | Zähler Datensatz 16 | D0 | 1 Bit | 1.10 start/stop | CT |
| 215 | Zähler Datensatz 16 | D0 | 1 Bit | 1.15 reset | CT |
| 215 | Zähler Datensatz 16 | D0 | 2 Bytes | 7.5 time (s) | CT |
| 215 | Zähler Datensatz 16 | D0 | 2 Bytes | 7.7 time (h) | CT |
| 215 | Zähler Datensatz 16 | D0 | 2 Bytes | 9.1 temperature (°C) | CT |
| 215 | Zähler Datensatz 16 | D0 | 2 Bytes | 9.2 temperature difference (K) | CT |
| 215 | Zähler Datensatz 16 | D0 | 2 Bytes | 9.3 kelvin/hour (K/h) | CT |
| 215 | Zähler Datensatz 16 | D0 | 2 Bytes | 9.6 pressure (Pa) | CT |
| 215 | Zähler Datensatz 16 | D0 | 2 Bytes | 9.10 time (s) | CT |
| 215 | Zähler Datensatz 16 | D0 | 2 Bytes | 9.20 voltage (mV) | CT |
| 215 | Zähler Datensatz 16 | D0 | 2 Bytes | 9.21 current (mA) | CT |
| 215 | Zähler Datensatz 16 | D0 | 2 Bytes | 9.24 power (kW) | CT |
| 215 | Zähler Datensatz 16 | D0 | 2 Bytes | 9.25 volume flow (l/h) | CT |
| 215 | Zähler Datensatz 16 | D0 | 2 Bytes | 9.27 temperature (°F) | CT |
| 215 | Zähler Datensatz 16 | D0 | 3 Bytes | 10.1 time of day | CT |
| 215 | Zähler Datensatz 16 | D0 | 3 Bytes | 11.1 date | CT |
| 215 | Zähler Datensatz 16 | D0 | 4 Bytes | 12.1 counter pulses (unsigned) | CT |
| 215 | Zähler Datensatz 16 | D0 | 4 Bytes | 13.2 flow rate (m³/h) | CT |
| 215 | Zähler Datensatz 16 | D0 | 4 Bytes | 13.10 active energy (Wh) | CT |
| 215 | Zähler Datensatz 16 | D0 | 4 Bytes | 13.11 apparant energy (VAh) | CT |
| 215 | Zähler Datensatz 16 | D0 | 4 Bytes | 13.12 reactive energy (VARh) | CT |
| 215 | Zähler Datensatz 16 | D0 | 4 Bytes | 13.13 active energy (kWh) | CT |
| 215 | Zähler Datensatz 16 | D0 | 4 Bytes | 13.14 apparent energy (kVAh) | CT |
| 215 | Zähler Datensatz 16 | D0 | 4 Bytes | 13.15 reactive energy (kVARh) | CT |
| 215 | Zähler Datensatz 16 | D0 | 4 Bytes | 13.100 time lag (s) | CT |
| 215 | Zähler Datensatz 16 | D0 | 4 Bytes | 14.19 electric current (A) | CT |
| 215 | Zähler Datensatz 16 | D0 | 4 Bytes | 14.27 electric potential (V) | CT |
| 215 | Zähler Datensatz 16 | D0 | 4 Bytes | 14.31 energy (J) | CT |
| 215 | Zähler Datensatz 16 | D0 | 4 Bytes | 14.33 frequency (Hz) | CT |
| 215 | Zähler Datensatz 16 | D0 | 4 Bytes | 14.56 power (W) | CT |
| 215 | Zähler Datensatz 16 | D0 | 4 Bytes | 14.57 power factor (cos Φ) | CT |
| 215 | Zähler Datensatz 16 | D0 | 4 Bytes | 14.68 temperature (°C) | CT |
| 215 | Zähler Datensatz 16 | D0 | 4 Bytes | 14.76 volume (m³) | CT |
| 215 | Zähler Datensatz 16 | D0 | 8 Bytes | 29.10 active energy (Wh) | CT |
| 215 | Zähler Datensatz 16 | D0 | 8 Bytes | 29.11 apparant energy (VAh) | CT |
| 215 | Zähler Datensatz 16 | D0 | 8 Bytes | 29.12 reactive energy (VARh) | CT |
| 216 | Zähler Datensatz 17 | D0 | 1 Bit | 1.1 switch | CT |
| 216 | Zähler Datensatz 17 | D0 | 1 Bit | 1.3 enable | CT |
| 216 | Zähler Datensatz 17 | D0 | 1 Bit | 1.10 start/stop | CT |
| 216 | Zähler Datensatz 17 | D0 | 1 Bit | 1.15 reset | CT |
| 216 | Zähler Datensatz 17 | D0 | 2 Bytes | 7.5 time (s) | CT |
| 216 | Zähler Datensatz 17 | D0 | 2 Bytes | 7.7 time (h) | CT |
| 216 | Zähler Datensatz 17 | D0 | 2 Bytes | 9.1 temperature (°C) | CT |
| 216 | Zähler Datensatz 17 | D0 | 2 Bytes | 9.2 temperature difference (K) | CT |
| 216 | Zähler Datensatz 17 | D0 | 2 Bytes | 9.3 kelvin/hour (K/h) | CT |
| 216 | Zähler Datensatz 17 | D0 | 2 Bytes | 9.6 pressure (Pa) | CT |
| 216 | Zähler Datensatz 17 | D0 | 2 Bytes | 9.10 time (s) | CT |
| 216 | Zähler Datensatz 17 | D0 | 2 Bytes | 9.20 voltage (mV) | CT |
| 216 | Zähler Datensatz 17 | D0 | 2 Bytes | 9.21 current (mA) | CT |
| 216 | Zähler Datensatz 17 | D0 | 2 Bytes | 9.24 power (kW) | CT |
| 216 | Zähler Datensatz 17 | D0 | 2 Bytes | 9.25 volume flow (l/h) | CT |
| 216 | Zähler Datensatz 17 | D0 | 2 Bytes | 9.27 temperature (°F) | CT |
| 216 | Zähler Datensatz 17 | D0 | 3 Bytes | 10.1 time of day | CT |
| 216 | Zähler Datensatz 17 | D0 | 3 Bytes | 11.1 date | CT |
| 216 | Zähler Datensatz 17 | D0 | 4 Bytes | 12.1 counter pulses (unsigned) | CT |
| 216 | Zähler Datensatz 17 | D0 | 4 Bytes | 13.2 flow rate (m³/h) | CT |
| 216 | Zähler Datensatz 17 | D0 | 4 Bytes | 13.10 active energy (Wh) | CT |
| 216 | Zähler Datensatz 17 | D0 | 4 Bytes | 13.11 apparant energy (VAh) | CT |
| 216 | Zähler Datensatz 17 | D0 | 4 Bytes | 13.12 reactive energy (VARh) | CT |
| 216 | Zähler Datensatz 17 | D0 | 4 Bytes | 13.13 active energy (kWh) | CT |
| 216 | Zähler Datensatz 17 | D0 | 4 Bytes | 13.14 apparent energy (kVAh) | CT |
| 216 | Zähler Datensatz 17 | D0 | 4 Bytes | 13.15 reactive energy (kVARh) | CT |
| 216 | Zähler Datensatz 17 | D0 | 4 Bytes | 13.100 time lag (s) | CT |
| 216 | Zähler Datensatz 17 | D0 | 4 Bytes | 14.19 electric current (A) | CT |
| 216 | Zähler Datensatz 17 | D0 | 4 Bytes | 14.27 electric potential (V) | CT |
| 216 | Zähler Datensatz 17 | D0 | 4 Bytes | 14.31 energy (J) | CT |
| 216 | Zähler Datensatz 17 | D0 | 4 Bytes | 14.33 frequency (Hz) | CT |
| 216 | Zähler Datensatz 17 | D0 | 4 Bytes | 14.56 power (W) | CT |
| 216 | Zähler Datensatz 17 | D0 | 4 Bytes | 14.57 power factor (cos Φ) | CT |
| 216 | Zähler Datensatz 17 | D0 | 4 Bytes | 14.68 temperature (°C) | CT |
| 216 | Zähler Datensatz 17 | D0 | 4 Bytes | 14.76 volume (m³) | CT |
| 216 | Zähler Datensatz 17 | D0 | 8 Bytes | 29.10 active energy (Wh) | CT |
| 216 | Zähler Datensatz 17 | D0 | 8 Bytes | 29.11 apparant energy (VAh) | CT |
| 216 | Zähler Datensatz 17 | D0 | 8 Bytes | 29.12 reactive energy (VARh) | CT |
| 217 | Zähler Datensatz 18 | D0 | 1 Bit | 1.1 switch | CT |
| 217 | Zähler Datensatz 18 | D0 | 1 Bit | 1.3 enable | CT |
| 217 | Zähler Datensatz 18 | D0 | 1 Bit | 1.10 start/stop | CT |
| 217 | Zähler Datensatz 18 | D0 | 1 Bit | 1.15 reset | CT |
| 217 | Zähler Datensatz 18 | D0 | 2 Bytes | 7.5 time (s) | CT |
| 217 | Zähler Datensatz 18 | D0 | 2 Bytes | 7.7 time (h) | CT |
| 217 | Zähler Datensatz 18 | D0 | 2 Bytes | 9.1 temperature (°C) | CT |
| 217 | Zähler Datensatz 18 | D0 | 2 Bytes | 9.2 temperature difference (K) | CT |
| 217 | Zähler Datensatz 18 | D0 | 2 Bytes | 9.3 kelvin/hour (K/h) | CT |
| 217 | Zähler Datensatz 18 | D0 | 2 Bytes | 9.6 pressure (Pa) | CT |
| 217 | Zähler Datensatz 18 | D0 | 2 Bytes | 9.10 time (s) | CT |
| 217 | Zähler Datensatz 18 | D0 | 2 Bytes | 9.20 voltage (mV) | CT |
| 217 | Zähler Datensatz 18 | D0 | 2 Bytes | 9.21 current (mA) | CT |
| 217 | Zähler Datensatz 18 | D0 | 2 Bytes | 9.24 power (kW) | CT |
| 217 | Zähler Datensatz 18 | D0 | 2 Bytes | 9.25 volume flow (l/h) | CT |
| 217 | Zähler Datensatz 18 | D0 | 2 Bytes | 9.27 temperature (°F) | CT |
| 217 | Zähler Datensatz 18 | D0 | 3 Bytes | 10.1 time of day | CT |
| 217 | Zähler Datensatz 18 | D0 | 3 Bytes | 11.1 date | CT |
| 217 | Zähler Datensatz 18 | D0 | 4 Bytes | 12.1 counter pulses (unsigned) | CT |
| 217 | Zähler Datensatz 18 | D0 | 4 Bytes | 13.2 flow rate (m³/h) | CT |
| 217 | Zähler Datensatz 18 | D0 | 4 Bytes | 13.10 active energy (Wh) | CT |
| 217 | Zähler Datensatz 18 | D0 | 4 Bytes | 13.11 apparant energy (VAh) | CT |
| 217 | Zähler Datensatz 18 | D0 | 4 Bytes | 13.12 reactive energy (VARh) | CT |
| 217 | Zähler Datensatz 18 | D0 | 4 Bytes | 13.13 active energy (kWh) | CT |
| 217 | Zähler Datensatz 18 | D0 | 4 Bytes | 13.14 apparent energy (kVAh) | CT |
| 217 | Zähler Datensatz 18 | D0 | 4 Bytes | 13.15 reactive energy (kVARh) | CT |
| 217 | Zähler Datensatz 18 | D0 | 4 Bytes | 13.100 time lag (s) | CT |
| 217 | Zähler Datensatz 18 | D0 | 4 Bytes | 14.19 electric current (A) | CT |
| 217 | Zähler Datensatz 18 | D0 | 4 Bytes | 14.27 electric potential (V) | CT |
| 217 | Zähler Datensatz 18 | D0 | 4 Bytes | 14.31 energy (J) | CT |
| 217 | Zähler Datensatz 18 | D0 | 4 Bytes | 14.33 frequency (Hz) | CT |
| 217 | Zähler Datensatz 18 | D0 | 4 Bytes | 14.56 power (W) | CT |
| 217 | Zähler Datensatz 18 | D0 | 4 Bytes | 14.57 power factor (cos Φ) | CT |
| 217 | Zähler Datensatz 18 | D0 | 4 Bytes | 14.68 temperature (°C) | CT |
| 217 | Zähler Datensatz 18 | D0 | 4 Bytes | 14.76 volume (m³) | CT |
| 217 | Zähler Datensatz 18 | D0 | 8 Bytes | 29.10 active energy (Wh) | CT |
| 217 | Zähler Datensatz 18 | D0 | 8 Bytes | 29.11 apparant energy (VAh) | CT |
| 217 | Zähler Datensatz 18 | D0 | 8 Bytes | 29.12 reactive energy (VARh) | CT |
| 218 | Zähler Datensatz 19 | D0 | 1 Bit | 1.1 switch | CT |
| 218 | Zähler Datensatz 19 | D0 | 1 Bit | 1.3 enable | CT |
| 218 | Zähler Datensatz 19 | D0 | 1 Bit | 1.10 start/stop | CT |
| 218 | Zähler Datensatz 19 | D0 | 1 Bit | 1.15 reset | CT |
| 218 | Zähler Datensatz 19 | D0 | 2 Bytes | 7.5 time (s) | CT |
| 218 | Zähler Datensatz 19 | D0 | 2 Bytes | 7.7 time (h) | CT |
| 218 | Zähler Datensatz 19 | D0 | 2 Bytes | 9.1 temperature (°C) | CT |
| 218 | Zähler Datensatz 19 | D0 | 2 Bytes | 9.2 temperature difference (K) | CT |
| 218 | Zähler Datensatz 19 | D0 | 2 Bytes | 9.3 kelvin/hour (K/h) | CT |
| 218 | Zähler Datensatz 19 | D0 | 2 Bytes | 9.6 pressure (Pa) | CT |
| 218 | Zähler Datensatz 19 | D0 | 2 Bytes | 9.10 time (s) | CT |
| 218 | Zähler Datensatz 19 | D0 | 2 Bytes | 9.20 voltage (mV) | CT |
| 218 | Zähler Datensatz 19 | D0 | 2 Bytes | 9.21 current (mA) | CT |
| 218 | Zähler Datensatz 19 | D0 | 2 Bytes | 9.24 power (kW) | CT |
| 218 | Zähler Datensatz 19 | D0 | 2 Bytes | 9.25 volume flow (l/h) | CT |
| 218 | Zähler Datensatz 19 | D0 | 2 Bytes | 9.27 temperature (°F) | CT |
| 218 | Zähler Datensatz 19 | D0 | 3 Bytes | 10.1 time of day | CT |
| 218 | Zähler Datensatz 19 | D0 | 3 Bytes | 11.1 date | CT |
| 218 | Zähler Datensatz 19 | D0 | 4 Bytes | 12.1 counter pulses (unsigned) | CT |
| 218 | Zähler Datensatz 19 | D0 | 4 Bytes | 13.2 flow rate (m³/h) | CT |
| 218 | Zähler Datensatz 19 | D0 | 4 Bytes | 13.10 active energy (Wh) | CT |
| 218 | Zähler Datensatz 19 | D0 | 4 Bytes | 13.11 apparant energy (VAh) | CT |
| 218 | Zähler Datensatz 19 | D0 | 4 Bytes | 13.12 reactive energy (VARh) | CT |
| 218 | Zähler Datensatz 19 | D0 | 4 Bytes | 13.13 active energy (kWh) | CT |
| 218 | Zähler Datensatz 19 | D0 | 4 Bytes | 13.14 apparent energy (kVAh) | CT |
| 218 | Zähler Datensatz 19 | D0 | 4 Bytes | 13.15 reactive energy (kVARh) | CT |
| 218 | Zähler Datensatz 19 | D0 | 4 Bytes | 13.100 time lag (s) | CT |
| 218 | Zähler Datensatz 19 | D0 | 4 Bytes | 14.19 electric current (A) | CT |
| 218 | Zähler Datensatz 19 | D0 | 4 Bytes | 14.27 electric potential (V) | CT |
| 218 | Zähler Datensatz 19 | D0 | 4 Bytes | 14.31 energy (J) | CT |
| 218 | Zähler Datensatz 19 | D0 | 4 Bytes | 14.33 frequency (Hz) | CT |
| 218 | Zähler Datensatz 19 | D0 | 4 Bytes | 14.56 power (W) | CT |
| 218 | Zähler Datensatz 19 | D0 | 4 Bytes | 14.57 power factor (cos Φ) | CT |
| 218 | Zähler Datensatz 19 | D0 | 4 Bytes | 14.68 temperature (°C) | CT |
| 218 | Zähler Datensatz 19 | D0 | 4 Bytes | 14.76 volume (m³) | CT |
| 218 | Zähler Datensatz 19 | D0 | 8 Bytes | 29.10 active energy (Wh) | CT |
| 218 | Zähler Datensatz 19 | D0 | 8 Bytes | 29.11 apparant energy (VAh) | CT |
| 218 | Zähler Datensatz 19 | D0 | 8 Bytes | 29.12 reactive energy (VARh) | CT |
| 219 | Zähler Datensatz 20 | D0 | 1 Bit | 1.1 switch | CT |
| 219 | Zähler Datensatz 20 | D0 | 1 Bit | 1.3 enable | CT |
| 219 | Zähler Datensatz 20 | D0 | 1 Bit | 1.10 start/stop | CT |
| 219 | Zähler Datensatz 20 | D0 | 1 Bit | 1.15 reset | CT |
| 219 | Zähler Datensatz 20 | D0 | 2 Bytes | 7.5 time (s) | CT |
| 219 | Zähler Datensatz 20 | D0 | 2 Bytes | 7.7 time (h) | CT |
| 219 | Zähler Datensatz 20 | D0 | 2 Bytes | 9.1 temperature (°C) | CT |
| 219 | Zähler Datensatz 20 | D0 | 2 Bytes | 9.2 temperature difference (K) | CT |
| 219 | Zähler Datensatz 20 | D0 | 2 Bytes | 9.3 kelvin/hour (K/h) | CT |
| 219 | Zähler Datensatz 20 | D0 | 2 Bytes | 9.6 pressure (Pa) | CT |
| 219 | Zähler Datensatz 20 | D0 | 2 Bytes | 9.10 time (s) | CT |
| 219 | Zähler Datensatz 20 | D0 | 2 Bytes | 9.20 voltage (mV) | CT |
| 219 | Zähler Datensatz 20 | D0 | 2 Bytes | 9.21 current (mA) | CT |
| 219 | Zähler Datensatz 20 | D0 | 2 Bytes | 9.24 power (kW) | CT |
| 219 | Zähler Datensatz 20 | D0 | 2 Bytes | 9.25 volume flow (l/h) | CT |
| 219 | Zähler Datensatz 20 | D0 | 2 Bytes | 9.27 temperature (°F) | CT |
| 219 | Zähler Datensatz 20 | D0 | 3 Bytes | 10.1 time of day | CT |
| 219 | Zähler Datensatz 20 | D0 | 3 Bytes | 11.1 date | CT |
| 219 | Zähler Datensatz 20 | D0 | 4 Bytes | 12.1 counter pulses (unsigned) | CT |
| 219 | Zähler Datensatz 20 | D0 | 4 Bytes | 13.2 flow rate (m³/h) | CT |
| 219 | Zähler Datensatz 20 | D0 | 4 Bytes | 13.10 active energy (Wh) | CT |
| 219 | Zähler Datensatz 20 | D0 | 4 Bytes | 13.11 apparant energy (VAh) | CT |
| 219 | Zähler Datensatz 20 | D0 | 4 Bytes | 13.12 reactive energy (VARh) | CT |
| 219 | Zähler Datensatz 20 | D0 | 4 Bytes | 13.13 active energy (kWh) | CT |
| 219 | Zähler Datensatz 20 | D0 | 4 Bytes | 13.14 apparent energy (kVAh) | CT |
| 219 | Zähler Datensatz 20 | D0 | 4 Bytes | 13.15 reactive energy (kVARh) | CT |
| 219 | Zähler Datensatz 20 | D0 | 4 Bytes | 13.100 time lag (s) | CT |
| 219 | Zähler Datensatz 20 | D0 | 4 Bytes | 14.19 electric current (A) | CT |
| 219 | Zähler Datensatz 20 | D0 | 4 Bytes | 14.27 electric potential (V) | CT |
| 219 | Zähler Datensatz 20 | D0 | 4 Bytes | 14.31 energy (J) | CT |
| 219 | Zähler Datensatz 20 | D0 | 4 Bytes | 14.33 frequency (Hz) | CT |
| 219 | Zähler Datensatz 20 | D0 | 4 Bytes | 14.56 power (W) | CT |
| 219 | Zähler Datensatz 20 | D0 | 4 Bytes | 14.57 power factor (cos Φ) | CT |
| 219 | Zähler Datensatz 20 | D0 | 4 Bytes | 14.68 temperature (°C) | CT |
| 219 | Zähler Datensatz 20 | D0 | 4 Bytes | 14.76 volume (m³) | CT |
| 219 | Zähler Datensatz 20 | D0 | 8 Bytes | 29.10 active energy (Wh) | CT |
| 219 | Zähler Datensatz 20 | D0 | 8 Bytes | 29.11 apparant energy (VAh) | CT |
| 219 | Zähler Datensatz 20 | D0 | 8 Bytes | 29.12 reactive energy (VARh) | CT |
| 220 | Zähler Datensatz 21 | D0 | 1 Bit | 1.1 switch | CT |
| 220 | Zähler Datensatz 21 | D0 | 1 Bit | 1.3 enable | CT |
| 220 | Zähler Datensatz 21 | D0 | 1 Bit | 1.10 start/stop | CT |
| 220 | Zähler Datensatz 21 | D0 | 1 Bit | 1.15 reset | CT |
| 220 | Zähler Datensatz 21 | D0 | 2 Bytes | 7.5 time (s) | CT |
| 220 | Zähler Datensatz 21 | D0 | 2 Bytes | 7.7 time (h) | CT |
| 220 | Zähler Datensatz 21 | D0 | 2 Bytes | 9.1 temperature (°C) | CT |
| 220 | Zähler Datensatz 21 | D0 | 2 Bytes | 9.2 temperature difference (K) | CT |
| 220 | Zähler Datensatz 21 | D0 | 2 Bytes | 9.3 kelvin/hour (K/h) | CT |
| 220 | Zähler Datensatz 21 | D0 | 2 Bytes | 9.6 pressure (Pa) | CT |
| 220 | Zähler Datensatz 21 | D0 | 2 Bytes | 9.10 time (s) | CT |
| 220 | Zähler Datensatz 21 | D0 | 2 Bytes | 9.20 voltage (mV) | CT |
| 220 | Zähler Datensatz 21 | D0 | 2 Bytes | 9.21 current (mA) | CT |
| 220 | Zähler Datensatz 21 | D0 | 2 Bytes | 9.24 power (kW) | CT |
| 220 | Zähler Datensatz 21 | D0 | 2 Bytes | 9.25 volume flow (l/h) | CT |
| 220 | Zähler Datensatz 21 | D0 | 2 Bytes | 9.27 temperature (°F) | CT |
| 220 | Zähler Datensatz 21 | D0 | 3 Bytes | 10.1 time of day | CT |
| 220 | Zähler Datensatz 21 | D0 | 3 Bytes | 11.1 date | CT |
| 220 | Zähler Datensatz 21 | D0 | 4 Bytes | 12.1 counter pulses (unsigned) | CT |
| 220 | Zähler Datensatz 21 | D0 | 4 Bytes | 13.2 flow rate (m³/h) | CT |
| 220 | Zähler Datensatz 21 | D0 | 4 Bytes | 13.10 active energy (Wh) | CT |
| 220 | Zähler Datensatz 21 | D0 | 4 Bytes | 13.11 apparant energy (VAh) | CT |
| 220 | Zähler Datensatz 21 | D0 | 4 Bytes | 13.12 reactive energy (VARh) | CT |
| 220 | Zähler Datensatz 21 | D0 | 4 Bytes | 13.13 active energy (kWh) | CT |
| 220 | Zähler Datensatz 21 | D0 | 4 Bytes | 13.14 apparent energy (kVAh) | CT |
| 220 | Zähler Datensatz 21 | D0 | 4 Bytes | 13.15 reactive energy (kVARh) | CT |
| 220 | Zähler Datensatz 21 | D0 | 4 Bytes | 13.100 time lag (s) | CT |
| 220 | Zähler Datensatz 21 | D0 | 4 Bytes | 14.19 electric current (A) | CT |
| 220 | Zähler Datensatz 21 | D0 | 4 Bytes | 14.27 electric potential (V) | CT |
| 220 | Zähler Datensatz 21 | D0 | 4 Bytes | 14.31 energy (J) | CT |
| 220 | Zähler Datensatz 21 | D0 | 4 Bytes | 14.33 frequency (Hz) | CT |
| 220 | Zähler Datensatz 21 | D0 | 4 Bytes | 14.56 power (W) | CT |
| 220 | Zähler Datensatz 21 | D0 | 4 Bytes | 14.57 power factor (cos Φ) | CT |
| 220 | Zähler Datensatz 21 | D0 | 4 Bytes | 14.68 temperature (°C) | CT |
| 220 | Zähler Datensatz 21 | D0 | 4 Bytes | 14.76 volume (m³) | CT |
| 220 | Zähler Datensatz 21 | D0 | 8 Bytes | 29.10 active energy (Wh) | CT |
| 220 | Zähler Datensatz 21 | D0 | 8 Bytes | 29.11 apparant energy (VAh) | CT |
| 220 | Zähler Datensatz 21 | D0 | 8 Bytes | 29.12 reactive energy (VARh) | CT |
| 221 | Zähler Datensatz 22 | D0 | 1 Bit | 1.1 switch | CT |
| 221 | Zähler Datensatz 22 | D0 | 1 Bit | 1.3 enable | CT |
| 221 | Zähler Datensatz 22 | D0 | 1 Bit | 1.10 start/stop | CT |
| 221 | Zähler Datensatz 22 | D0 | 1 Bit | 1.15 reset | CT |
| 221 | Zähler Datensatz 22 | D0 | 2 Bytes | 7.5 time (s) | CT |
| 221 | Zähler Datensatz 22 | D0 | 2 Bytes | 7.7 time (h) | CT |
| 221 | Zähler Datensatz 22 | D0 | 2 Bytes | 9.1 temperature (°C) | CT |
| 221 | Zähler Datensatz 22 | D0 | 2 Bytes | 9.2 temperature difference (K) | CT |
| 221 | Zähler Datensatz 22 | D0 | 2 Bytes | 9.3 kelvin/hour (K/h) | CT |
| 221 | Zähler Datensatz 22 | D0 | 2 Bytes | 9.6 pressure (Pa) | CT |
| 221 | Zähler Datensatz 22 | D0 | 2 Bytes | 9.10 time (s) | CT |
| 221 | Zähler Datensatz 22 | D0 | 2 Bytes | 9.20 voltage (mV) | CT |
| 221 | Zähler Datensatz 22 | D0 | 2 Bytes | 9.21 current (mA) | CT |
| 221 | Zähler Datensatz 22 | D0 | 2 Bytes | 9.24 power (kW) | CT |
| 221 | Zähler Datensatz 22 | D0 | 2 Bytes | 9.25 volume flow (l/h) | CT |
| 221 | Zähler Datensatz 22 | D0 | 2 Bytes | 9.27 temperature (°F) | CT |
| 221 | Zähler Datensatz 22 | D0 | 3 Bytes | 10.1 time of day | CT |
| 221 | Zähler Datensatz 22 | D0 | 3 Bytes | 11.1 date | CT |
| 221 | Zähler Datensatz 22 | D0 | 4 Bytes | 12.1 counter pulses (unsigned) | CT |
| 221 | Zähler Datensatz 22 | D0 | 4 Bytes | 13.2 flow rate (m³/h) | CT |
| 221 | Zähler Datensatz 22 | D0 | 4 Bytes | 13.10 active energy (Wh) | CT |
| 221 | Zähler Datensatz 22 | D0 | 4 Bytes | 13.11 apparant energy (VAh) | CT |
| 221 | Zähler Datensatz 22 | D0 | 4 Bytes | 13.12 reactive energy (VARh) | CT |
| 221 | Zähler Datensatz 22 | D0 | 4 Bytes | 13.13 active energy (kWh) | CT |
| 221 | Zähler Datensatz 22 | D0 | 4 Bytes | 13.14 apparent energy (kVAh) | CT |
| 221 | Zähler Datensatz 22 | D0 | 4 Bytes | 13.15 reactive energy (kVARh) | CT |
| 221 | Zähler Datensatz 22 | D0 | 4 Bytes | 13.100 time lag (s) | CT |
| 221 | Zähler Datensatz 22 | D0 | 4 Bytes | 14.19 electric current (A) | CT |
| 221 | Zähler Datensatz 22 | D0 | 4 Bytes | 14.27 electric potential (V) | CT |
| 221 | Zähler Datensatz 22 | D0 | 4 Bytes | 14.31 energy (J) | CT |
| 221 | Zähler Datensatz 22 | D0 | 4 Bytes | 14.33 frequency (Hz) | CT |
| 221 | Zähler Datensatz 22 | D0 | 4 Bytes | 14.56 power (W) | CT |
| 221 | Zähler Datensatz 22 | D0 | 4 Bytes | 14.57 power factor (cos Φ) | CT |
| 221 | Zähler Datensatz 22 | D0 | 4 Bytes | 14.68 temperature (°C) | CT |
| 221 | Zähler Datensatz 22 | D0 | 4 Bytes | 14.76 volume (m³) | CT |
| 221 | Zähler Datensatz 22 | D0 | 8 Bytes | 29.10 active energy (Wh) | CT |
| 221 | Zähler Datensatz 22 | D0 | 8 Bytes | 29.11 apparant energy (VAh) | CT |
| 221 | Zähler Datensatz 22 | D0 | 8 Bytes | 29.12 reactive energy (VARh) | CT |
| 222 | Zähler Datensatz 23 | D0 | 1 Bit | 1.1 switch | CT |
| 222 | Zähler Datensatz 23 | D0 | 1 Bit | 1.3 enable | CT |
| 222 | Zähler Datensatz 23 | D0 | 1 Bit | 1.10 start/stop | CT |
| 222 | Zähler Datensatz 23 | D0 | 1 Bit | 1.15 reset | CT |
| 222 | Zähler Datensatz 23 | D0 | 2 Bytes | 7.5 time (s) | CT |
| 222 | Zähler Datensatz 23 | D0 | 2 Bytes | 7.7 time (h) | CT |
| 222 | Zähler Datensatz 23 | D0 | 2 Bytes | 9.1 temperature (°C) | CT |
| 222 | Zähler Datensatz 23 | D0 | 2 Bytes | 9.2 temperature difference (K) | CT |
| 222 | Zähler Datensatz 23 | D0 | 2 Bytes | 9.3 kelvin/hour (K/h) | CT |
| 222 | Zähler Datensatz 23 | D0 | 2 Bytes | 9.6 pressure (Pa) | CT |
| 222 | Zähler Datensatz 23 | D0 | 2 Bytes | 9.10 time (s) | CT |
| 222 | Zähler Datensatz 23 | D0 | 2 Bytes | 9.20 voltage (mV) | CT |
| 222 | Zähler Datensatz 23 | D0 | 2 Bytes | 9.21 current (mA) | CT |
| 222 | Zähler Datensatz 23 | D0 | 2 Bytes | 9.24 power (kW) | CT |
| 222 | Zähler Datensatz 23 | D0 | 2 Bytes | 9.25 volume flow (l/h) | CT |
| 222 | Zähler Datensatz 23 | D0 | 2 Bytes | 9.27 temperature (°F) | CT |
| 222 | Zähler Datensatz 23 | D0 | 3 Bytes | 10.1 time of day | CT |
| 222 | Zähler Datensatz 23 | D0 | 3 Bytes | 11.1 date | CT |
| 222 | Zähler Datensatz 23 | D0 | 4 Bytes | 12.1 counter pulses (unsigned) | CT |
| 222 | Zähler Datensatz 23 | D0 | 4 Bytes | 13.2 flow rate (m³/h) | CT |
| 222 | Zähler Datensatz 23 | D0 | 4 Bytes | 13.10 active energy (Wh) | CT |
| 222 | Zähler Datensatz 23 | D0 | 4 Bytes | 13.11 apparant energy (VAh) | CT |
| 222 | Zähler Datensatz 23 | D0 | 4 Bytes | 13.12 reactive energy (VARh) | CT |
| 222 | Zähler Datensatz 23 | D0 | 4 Bytes | 13.13 active energy (kWh) | CT |
| 222 | Zähler Datensatz 23 | D0 | 4 Bytes | 13.14 apparent energy (kVAh) | CT |
| 222 | Zähler Datensatz 23 | D0 | 4 Bytes | 13.15 reactive energy (kVARh) | CT |
| 222 | Zähler Datensatz 23 | D0 | 4 Bytes | 13.100 time lag (s) | CT |
| 222 | Zähler Datensatz 23 | D0 | 4 Bytes | 14.19 electric current (A) | CT |
| 222 | Zähler Datensatz 23 | D0 | 4 Bytes | 14.27 electric potential (V) | CT |
| 222 | Zähler Datensatz 23 | D0 | 4 Bytes | 14.31 energy (J) | CT |
| 222 | Zähler Datensatz 23 | D0 | 4 Bytes | 14.33 frequency (Hz) | CT |
| 222 | Zähler Datensatz 23 | D0 | 4 Bytes | 14.56 power (W) | CT |
| 222 | Zähler Datensatz 23 | D0 | 4 Bytes | 14.57 power factor (cos Φ) | CT |
| 222 | Zähler Datensatz 23 | D0 | 4 Bytes | 14.68 temperature (°C) | CT |
| 222 | Zähler Datensatz 23 | D0 | 4 Bytes | 14.76 volume (m³) | CT |
| 222 | Zähler Datensatz 23 | D0 | 8 Bytes | 29.10 active energy (Wh) | CT |
| 222 | Zähler Datensatz 23 | D0 | 8 Bytes | 29.11 apparant energy (VAh) | CT |
| 222 | Zähler Datensatz 23 | D0 | 8 Bytes | 29.12 reactive energy (VARh) | CT |
| 223 | Zähler Datensatz 24 | D0 | 1 Bit | 1.1 switch | CT |
| 223 | Zähler Datensatz 24 | D0 | 1 Bit | 1.3 enable | CT |
| 223 | Zähler Datensatz 24 | D0 | 1 Bit | 1.10 start/stop | CT |
| 223 | Zähler Datensatz 24 | D0 | 1 Bit | 1.15 reset | CT |
| 223 | Zähler Datensatz 24 | D0 | 2 Bytes | 7.5 time (s) | CT |
| 223 | Zähler Datensatz 24 | D0 | 2 Bytes | 7.7 time (h) | CT |
| 223 | Zähler Datensatz 24 | D0 | 2 Bytes | 9.1 temperature (°C) | CT |
| 223 | Zähler Datensatz 24 | D0 | 2 Bytes | 9.2 temperature difference (K) | CT |
| 223 | Zähler Datensatz 24 | D0 | 2 Bytes | 9.3 kelvin/hour (K/h) | CT |
| 223 | Zähler Datensatz 24 | D0 | 2 Bytes | 9.6 pressure (Pa) | CT |
| 223 | Zähler Datensatz 24 | D0 | 2 Bytes | 9.10 time (s) | CT |
| 223 | Zähler Datensatz 24 | D0 | 2 Bytes | 9.20 voltage (mV) | CT |
| 223 | Zähler Datensatz 24 | D0 | 2 Bytes | 9.21 current (mA) | CT |
| 223 | Zähler Datensatz 24 | D0 | 2 Bytes | 9.24 power (kW) | CT |
| 223 | Zähler Datensatz 24 | D0 | 2 Bytes | 9.25 volume flow (l/h) | CT |
| 223 | Zähler Datensatz 24 | D0 | 2 Bytes | 9.27 temperature (°F) | CT |
| 223 | Zähler Datensatz 24 | D0 | 3 Bytes | 10.1 time of day | CT |
| 223 | Zähler Datensatz 24 | D0 | 3 Bytes | 11.1 date | CT |
| 223 | Zähler Datensatz 24 | D0 | 4 Bytes | 12.1 counter pulses (unsigned) | CT |
| 223 | Zähler Datensatz 24 | D0 | 4 Bytes | 13.2 flow rate (m³/h) | CT |
| 223 | Zähler Datensatz 24 | D0 | 4 Bytes | 13.10 active energy (Wh) | CT |
| 223 | Zähler Datensatz 24 | D0 | 4 Bytes | 13.11 apparant energy (VAh) | CT |
| 223 | Zähler Datensatz 24 | D0 | 4 Bytes | 13.12 reactive energy (VARh) | CT |
| 223 | Zähler Datensatz 24 | D0 | 4 Bytes | 13.13 active energy (kWh) | CT |
| 223 | Zähler Datensatz 24 | D0 | 4 Bytes | 13.14 apparent energy (kVAh) | CT |
| 223 | Zähler Datensatz 24 | D0 | 4 Bytes | 13.15 reactive energy (kVARh) | CT |
| 223 | Zähler Datensatz 24 | D0 | 4 Bytes | 13.100 time lag (s) | CT |
| 223 | Zähler Datensatz 24 | D0 | 4 Bytes | 14.19 electric current (A) | CT |
| 223 | Zähler Datensatz 24 | D0 | 4 Bytes | 14.27 electric potential (V) | CT |
| 223 | Zähler Datensatz 24 | D0 | 4 Bytes | 14.31 energy (J) | CT |
| 223 | Zähler Datensatz 24 | D0 | 4 Bytes | 14.33 frequency (Hz) | CT |
| 223 | Zähler Datensatz 24 | D0 | 4 Bytes | 14.56 power (W) | CT |
| 223 | Zähler Datensatz 24 | D0 | 4 Bytes | 14.57 power factor (cos Φ) | CT |
| 223 | Zähler Datensatz 24 | D0 | 4 Bytes | 14.68 temperature (°C) | CT |
| 223 | Zähler Datensatz 24 | D0 | 4 Bytes | 14.76 volume (m³) | CT |
| 223 | Zähler Datensatz 24 | D0 | 8 Bytes | 29.10 active energy (Wh) | CT |
| 223 | Zähler Datensatz 24 | D0 | 8 Bytes | 29.11 apparant energy (VAh) | CT |
| 223 | Zähler Datensatz 24 | D0 | 8 Bytes | 29.12 reactive energy (VARh) | CT |
| 224 | Zähler Datensatz 25 | D0 | 1 Bit | 1.1 switch | CT |
| 224 | Zähler Datensatz 25 | D0 | 1 Bit | 1.3 enable | CT |
| 224 | Zähler Datensatz 25 | D0 | 1 Bit | 1.10 start/stop | CT |
| 224 | Zähler Datensatz 25 | D0 | 1 Bit | 1.15 reset | CT |
| 224 | Zähler Datensatz 25 | D0 | 2 Bytes | 7.5 time (s) | CT |
| 224 | Zähler Datensatz 25 | D0 | 2 Bytes | 7.7 time (h) | CT |
| 224 | Zähler Datensatz 25 | D0 | 2 Bytes | 9.1 temperature (°C) | CT |
| 224 | Zähler Datensatz 25 | D0 | 2 Bytes | 9.2 temperature difference (K) | CT |
| 224 | Zähler Datensatz 25 | D0 | 2 Bytes | 9.3 kelvin/hour (K/h) | CT |
| 224 | Zähler Datensatz 25 | D0 | 2 Bytes | 9.6 pressure (Pa) | CT |
| 224 | Zähler Datensatz 25 | D0 | 2 Bytes | 9.10 time (s) | CT |
| 224 | Zähler Datensatz 25 | D0 | 2 Bytes | 9.20 voltage (mV) | CT |
| 224 | Zähler Datensatz 25 | D0 | 2 Bytes | 9.21 current (mA) | CT |
| 224 | Zähler Datensatz 25 | D0 | 2 Bytes | 9.24 power (kW) | CT |
| 224 | Zähler Datensatz 25 | D0 | 2 Bytes | 9.25 volume flow (l/h) | CT |
| 224 | Zähler Datensatz 25 | D0 | 2 Bytes | 9.27 temperature (°F) | CT |
| 224 | Zähler Datensatz 25 | D0 | 3 Bytes | 10.1 time of day | CT |
| 224 | Zähler Datensatz 25 | D0 | 3 Bytes | 11.1 date | CT |
| 224 | Zähler Datensatz 25 | D0 | 4 Bytes | 12.1 counter pulses (unsigned) | CT |
| 224 | Zähler Datensatz 25 | D0 | 4 Bytes | 13.2 flow rate (m³/h) | CT |
| 224 | Zähler Datensatz 25 | D0 | 4 Bytes | 13.10 active energy (Wh) | CT |
| 224 | Zähler Datensatz 25 | D0 | 4 Bytes | 13.11 apparant energy (VAh) | CT |
| 224 | Zähler Datensatz 25 | D0 | 4 Bytes | 13.12 reactive energy (VARh) | CT |
| 224 | Zähler Datensatz 25 | D0 | 4 Bytes | 13.13 active energy (kWh) | CT |
| 224 | Zähler Datensatz 25 | D0 | 4 Bytes | 13.14 apparent energy (kVAh) | CT |
| 224 | Zähler Datensatz 25 | D0 | 4 Bytes | 13.15 reactive energy (kVARh) | CT |
| 224 | Zähler Datensatz 25 | D0 | 4 Bytes | 13.100 time lag (s) | CT |
First 1000 of 24357 group objects shown. Download the .knxprod for the full list.
Parameters (729)
| Parameter | Type | Default |
|---|---|---|
| KNX Zählerausgabe | list | KNX-Zählerausgabe aktiviert |
| Externes Modul | list | Kein externes Modul vorhanden |
| Sendeverzögerung bei Versorgungspannungswiederkehr | list | 5 s |
| Sendepause nach letztem Zähler | list | 10 min |
| Sendepause zwischen einzelnen Zählern | list | 0,2 s |
| Sendepause zwischen einzelnen Datensätzen | list | 0,1 s |
| Logging auf SD Karte | list | Nicht aktiviert |
| Logging Zeitintervall | list | 60 min |
| Web-Server | list | Aktiviert |
| Datum und Uhrzeit | list | Vom Time-Server anfordern |
| Konfiguration Netzwerk | list | DHCP-Server verwenden |
| Sprache Webseite | list | Deutsch |
| IP-Adresse | ipAddress | 192.168.0.100 |
| Subnetzmaske | ipAddress | 255.255.255.0 |
| Standardgateway | ipAddress | 192.168.0.1 |
| Passwort für Webseite | text | |
| URL Timeserver | text | 1.de.pool.ntp.org |
| Zeitzone | list | UTC+1h: Amsterdam, Berlin, Bern, Rom, Stockholm, Wien, Brüssel, Kopenhagen, Madrid, Paris, Warschau, Zagreb, West-Zentralafrika |
| Länderauswahl | unsignedInt 0…254 | 0 |
| Zähler S0 1 | list | Nicht aktiviert |
| Zählername ( " & ' < > kann nicht verwendet werden! ) | text | S0 1 |
| Anzahl aktive Datensätze | unsignedInt 0…2 | 2 |
| Zählerstand speichern bei Spannungsausfall | list | Ja |
| Zählerstand Vorgabewert | float 0…3.4028234663852e+38 | 0 |
| Maximale Impulslänge | unsignedInt 25…6500 | 1000 |
| Timeout für Leerlauferkennung | unsignedInt 10…65534 | 90 |
| Impulswertigkeit Faktor | unsignedInt 1…50000 | 1000 |
| Impulswertigkeit Einheit | list | Impulse / kWh |
| Datenpunkttyp | list | 13.010, Wirkarbeit (Wh), 4 Byte |
| Faktor | float -3.4028234663852e+38…3.4028234663852e+38 | 1 |
| Offset | float -3.4028234663852e+38…3.4028234663852e+38 | 0 |
| Aktivierung Datensatz | list | Aktiviert |
| Sendeverhalten | list | Zyklisch senden |
| Senden bei Änderung um | unsignedInt 1…65535 | 10 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | S0 1.1 |
| Zähler D0 | list | Nicht aktiviert |
| Zählername ( " & ' < > kann nicht verwendet werden! ) | text | D0 |
| Anzahl aktive Datensätze | unsignedInt 1…30 | 1 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | D0.1 |
| Anzahl Zähler | unsignedInt 0…20 | 1 |
| Anzahl aktive Datensätze | unsignedInt 0…30 | 1 |
| Zählername ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 1 |
| Aktivierung M-Bus | list | M-Bus aktiviert |
| Aktivierung wM-Bus | list | wM-Bus aktiviert |
| Adressierung | list | Sekundär-Adressierung |
| Baudrate | list | 2400 Baud (M-Bus) |
| Maximale Primär-Adresse | unsignedInt 2…253 | 253 |
| Minimale Primär-Adresse | unsignedInt 1…253 | 1 |
| Zählertyp | list | M-Bus-Zähler |
| Primär-Adresse | unsignedInt 1…253 | 1 |
| Datensatz empfangen | list | Aktiviert |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 1.1 |
| Sekundär-Adresse | unsignedInt 0…4294967295 | 0 |
| Datensatznummer | unsignedInt 0…65535 | 0 |
| Anzahl wireless Zähler | unsignedInt 0…20 | 0 |
| AES-Schlüssel | text | 0 |
| Kommunikations-Mode wMBus | list | T1 |
| Timeout für Fehlermeldung | list | 10 min |
| Datensatz für historische Daten | list | Kein Datensatz |
| Einheit | list | Keine Einheit |
| Datensatz für historische Daten | list | kein Datensatz |
| Protokollauswahl | list | Mode-C |
| Stunde | list | Nicht aktiviert |
| Tag | list | Nicht aktiviert |
| Woche | list | Nicht aktiviert |
| Monat | list | Nicht aktiviert |
| Anzahl Datenbits | list | 8 Datenbits |
| Anzahl Stopbits | list | 1 Stop-Bit |
| Parität | list | Keine |
| Variante | list | M-Bus und wM-BusTransceiver bestückt |
| Datenpunkttyp | list | 1.001, Schalten, 1Bit |
| Zählerstand Vorgabewert übernehmen | list | Zählerstand-Vorgabewert nicht übernehmen |
| Automatische Sommer-Winterzeit Umschaltung | list | Aktiviert |
| Zähler S0 2 | list | Nicht aktiviert |
| M-Bus | list | Nicht aktiviert |
| Sekundär-Adresse | text | 00000000 |
| AES-Schlüssel | text | 00000000000000000000000000000000 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | S0 1.2 |
| Datenpunkttyp | list | 14.056, Leistung (W), 4 Byte |
| Zählername ( " & ' < > kann nicht verwendet werden! ) | text | S0 2 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | S0 2.1 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | S0 2.2 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | D0.2 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | D0.3 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | D0.4 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | D0.5 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | D0.6 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | D0.7 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | D0.8 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | D0.9 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | D0.10 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | D0.11 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | D0.12 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | D0.13 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | D0.14 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | D0.15 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | D0.16 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | D0.17 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | D0.18 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | D0.19 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | D0.20 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | D0.21 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | D0.22 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | D0.23 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | D0.24 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | D0.25 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | D0.26 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | D0.27 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | D0.28 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | D0.29 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | D0.30 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 1.2 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 1.3 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 1.4 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 1.5 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 1.6 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 1.7 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 1.8 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 1.9 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 1.10 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 1.11 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 1.12 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 1.13 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 1.14 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 1.15 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 1.16 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 1.17 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 1.18 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 1.19 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 1.20 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 1.21 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 1.22 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 1.23 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 1.24 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 1.25 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 1.26 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 1.27 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 1.28 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 1.29 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 1.30 |
| Zählername ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 2 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 2.1 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 2.2 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 2.3 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 2.4 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 2.5 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 2.6 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 2.7 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 2.8 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 2.9 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 2.10 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 2.11 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 2.12 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 2.13 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 2.14 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 2.15 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 2.16 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 2.17 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 2.18 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 2.19 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 2.20 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 2.21 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 2.22 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 2.23 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 2.24 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 2.25 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 2.26 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 2.27 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 2.28 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 2.29 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 2.30 |
| Zählername ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 3 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 3.1 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 3.2 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 3.3 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 3.4 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 3.5 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 3.6 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 3.7 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 3.8 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 3.9 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 3.10 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 3.11 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 3.12 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 3.13 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 3.14 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 3.15 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 3.16 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 3.17 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 3.18 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 3.19 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 3.20 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 3.21 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 3.22 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 3.23 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 3.24 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 3.25 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 3.26 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 3.27 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 3.28 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 3.29 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 3.30 |
| Zählername ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 4 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 4.1 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 4.2 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 4.3 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 4.4 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 4.5 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 4.6 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 4.7 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 4.8 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 4.9 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 4.10 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 4.11 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 4.12 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 4.13 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 4.14 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 4.15 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 4.16 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 4.17 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 4.18 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 4.19 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 4.20 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 4.21 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 4.22 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 4.23 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 4.24 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 4.25 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 4.26 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 4.27 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 4.28 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 4.29 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 4.30 |
| Zählername ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 5 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 5.1 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 5.2 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 5.3 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 5.4 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 5.5 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 5.6 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 5.7 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 5.8 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 5.9 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 5.10 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 5.11 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 5.12 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 5.13 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 5.14 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 5.15 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 5.16 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 5.17 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 5.18 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 5.19 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 5.20 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 5.21 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 5.22 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 5.23 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 5.24 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 5.25 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 5.26 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 5.27 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 5.28 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 5.29 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 5.30 |
| Zählername ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 6 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 6.1 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 6.2 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 6.3 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 6.4 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 6.5 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 6.6 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 6.7 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 6.8 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 6.9 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 6.10 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 6.11 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 6.12 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 6.13 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 6.14 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 6.15 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 6.16 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 6.17 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 6.18 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 6.19 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 6.20 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 6.21 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 6.22 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 6.23 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 6.24 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 6.25 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 6.26 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 6.27 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 6.28 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 6.29 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 6.30 |
| Zählername ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 7 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 7.1 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 7.2 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 7.3 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 7.4 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 7.5 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 7.6 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 7.7 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 7.8 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 7.9 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 7.10 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 7.11 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 7.12 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 7.13 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 7.14 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 7.15 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 7.16 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 7.17 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 7.18 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 7.19 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 7.20 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 7.21 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 7.22 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 7.23 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 7.24 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 7.25 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 7.26 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 7.27 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 7.28 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 7.29 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 7.30 |
| Zählername ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 8 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 8.1 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 8.2 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 8.3 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 8.4 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 8.5 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 8.6 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 8.7 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 8.8 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 8.9 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 8.10 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 8.11 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 8.12 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 8.13 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 8.14 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 8.15 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 8.16 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 8.17 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 8.18 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 8.19 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 8.20 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 8.21 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 8.22 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 8.23 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 8.24 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 8.25 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 8.26 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 8.27 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 8.28 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 8.29 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 8.30 |
| Zählername ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 9 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 9.1 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 9.2 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 9.3 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 9.4 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 9.5 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 9.6 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 9.7 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 9.8 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 9.9 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 9.10 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 9.11 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 9.12 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 9.13 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 9.14 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 9.15 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 9.16 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 9.17 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 9.18 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 9.19 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 9.20 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 9.21 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 9.22 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 9.23 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 9.24 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 9.25 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 9.26 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 9.27 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 9.28 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 9.29 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 9.30 |
| Zählername ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 10 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 10.1 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 10.2 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 10.3 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 10.4 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 10.5 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 10.6 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 10.7 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 10.8 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 10.9 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 10.10 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 10.11 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 10.12 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 10.13 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 10.14 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 10.15 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 10.16 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 10.17 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 10.18 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 10.19 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 10.20 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 10.21 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 10.22 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 10.23 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 10.24 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 10.25 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 10.26 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 10.27 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 10.28 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 10.29 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 10.30 |
| Zählername ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 11 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 11.1 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 11.2 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 11.3 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 11.4 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 11.5 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 11.6 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 11.7 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 11.8 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 11.9 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 11.10 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 11.11 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 11.12 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 11.13 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 11.14 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 11.15 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 11.16 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 11.17 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 11.18 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 11.19 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 11.20 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 11.21 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 11.22 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 11.23 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 11.24 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 11.25 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 11.26 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 11.27 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 11.28 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 11.29 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 11.30 |
| Zählername ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 12 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 12.1 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 12.2 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 12.3 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 12.4 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 12.5 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 12.6 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 12.7 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 12.8 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 12.9 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 12.10 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 12.11 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 12.12 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 12.13 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 12.14 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 12.15 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 12.16 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 12.17 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 12.18 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 12.19 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 12.20 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 12.21 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 12.22 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 12.23 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 12.24 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 12.25 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 12.26 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 12.27 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 12.28 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 12.29 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 12.30 |
| Zählername ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 13 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 13.1 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 13.2 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 13.3 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 13.4 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 13.5 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 13.6 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 13.7 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 13.8 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 13.9 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 13.10 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 13.11 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 13.12 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 13.13 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 13.14 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 13.15 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 13.16 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 13.17 |
| Datensatzname ( " & ' < > kann nicht verwendet werden! ) | text | M-Bus / wM-Bus 13.18 |
First 500 of 729 parameters shown. Download the .knxprod for the full list.
Version history
| Application | App no | Fingerprint | First seen | Size | File |
|---|---|---|---|---|---|
| KNX Metering gateway C01911 1.1 latest | $C019 | 293F | 2026-11-25 | 722 KB | Download |
About this file
This is the official ETS product database for the ELKA-Elektronik GmbH KNX Metering gateway wM-Bus/M-Bus (13516140), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.
More from ELKA-Elektronik GmbH
- KNX weather station compact 135 157 00
- MBT 2424 13514300
- KNX Weather station comfort plus 13515800
- Motor actuator 13518014