KNX Database
Ekinex S.p.A. EK-ERA-TP KNX ERA series pushbutton

KNX ERA series pushbutton EK-ERA-TP

Ekinex S.p.A. · Order number EK-ERA-TP · Pushbuttons and displays

KNX ERA series pushbutton

Download .knxprod APERATP 0.1 · 532 KB

Product

ManufacturerEkinex S.p.A.
Product nameKNX ERA series pushbutton
Order numberEK-ERA-TP
HardwareKNX ERA series pushbutton
MediumTwisted Pair
Bus current (mA)23
Rail mountedNo
RegistrationCertified · 2025-10-17
Languagesen-US, de-DE, fr-FR, it-IT
Catalog entryM-00B6_H-00B600000130-1_HP-5241-01-A8B2_CI-EK.2DERA.2DTP-1
FingerprintA8B2
SHA-2565a66d8036de8d2c69cf74906ded28535d2854a2e37c1f855dd6fc74bbf22d5ab
First seen2026-11-25
Markets69 markets

Application program: APERATP 0.1

Application number$5241
Version0.1
Mask versionMV-07B0 (System B)
KNX Data SecureNo
Minimum ETS version5.0
Parameters2901
Group objects778
Group objects (778)
NoNameFunctionSizeDPTFlags
1Technical alarm1 Bit1.5 alarmCW
2Max leds intensity percentage1 Byte5.1 percentage (0..100%)CW
3Proximity sensor1 Bit1.17 triggerCWTU
4Button 1A - Lock command1 Bit1.3 enableCW
4Buttons 1 and 2 - Lock command1 Bit1.3 enableCW
5Button 1A - Switching status 1-bit object 11 Bit1.1 switchCWTU
5Button 1A - Switching status 2-bits object 12 Bit2.1 switch controlCWTU
5Button 1A - Switching status 1-unsigned byte object 11 Byte5.1 percentage (0..100%)CWTU
5Button 1A - Switching status 1-signed byte object 11 Byte6.1 percentage (-128..127%)CWTU
5Button 1A - Switching status 2-unsigned bytes object 12 Bytes7.1 pulsesCWTU
5Button 1A - Switching status 2-signed bytes object 12 Bytes8.1 pulses differenceCWTU
5Button 1A - Switching status 2-bytes floating value object 12 Bytes9.1 temperature (°C)CWTU
6Button 1A - Switching status 1-bit object 21 Bit1.1 switchCWTU
6Button 1A - Switching status 2-bits object 22 Bit2.1 switch controlCWTU
6Button 1A - Switching status 1-unsigned byte object 21 Byte5.1 percentage (0..100%)CWTU
6Button 1A - Switching status 1-signed byte object 21 Byte6.1 percentage (-128..127%)CWTU
6Button 1A - Switching status 2-unsigned bytes object 22 Bytes7.1 pulsesCWTU
6Button 1A - Switching status 2-signed bytes object 22 Bytes8.1 pulses differenceCWTU
6Button 1A - Switching status 2-bytes floating value object 22 Bytes9.1 temperature (°C)CWTU
7Button 1A - Switching status 1-bit object 31 Bit1.1 switchCWTU
7Button 1A - Switching status 2-bits object 32 Bit2.1 switch controlCWTU
7Button 1A - Switching status 1-unsigned byte object 31 Byte5.1 percentage (0..100%)CWTU
7Button 1A - Switching status 1-signed byte object 31 Byte6.1 percentage (-128..127%)CWTU
7Button 1A - Switching status 2-unsigned bytes object 32 Bytes7.1 pulsesCWTU
7Button 1A - Switching status 2-signed bytes object 32 Bytes8.1 pulses differenceCWTU
7Button 1A - Switching status 2-bytes floating value object 32 Bytes9.1 temperature (°C)CWTU
8Button 1A - Switching status 1-bit object 41 Bit1.1 switchCWTU
8Button 1A - Switching status 2-bits object 42 Bit2.1 switch controlCWTU
8Button 1A - Switching status 1-unsigned byte object 41 Byte5.1 percentage (0..100%)CWTU
8Button 1A - Switching status 1-signed byte object 41 Byte6.1 percentage (-128..127%)CWTU
8Button 1A - Switching status 2-unsigned bytes object 42 Bytes7.1 pulsesCWTU
8Button 1A - Switching status 2-signed bytes object 42 Bytes8.1 pulses differenceCWTU
8Button 1A - Switching status 2-bytes floating value object 42 Bytes9.1 temperature (°C)CWTU
9Button 1A - Switching status 1-bit object 51 Bit1.1 switchCWTU
9Button 1A - Switching status 2-bits object 52 Bit2.1 switch controlCWTU
9Button 1A - Switching status 1-unsigned byte object 51 Byte5.1 percentage (0..100%)CWTU
9Button 1A - Switching status 1-signed byte object 51 Byte6.1 percentage (-128..127%)CWTU
9Button 1A - Switching status 2-unsigned bytes object 52 Bytes7.1 pulsesCWTU
9Button 1A - Switching status 2-signed bytes object 52 Bytes8.1 pulses differenceCWTU
9Button 1A - Switching status 2-bytes floating value object 52 Bytes9.1 temperature (°C)CWTU
10Button 1A - Switching status 1-bit object 61 Bit1.1 switchCWTU
10Button 1A - Switching status 2-bits object 62 Bit2.1 switch controlCWTU
10Button 1A - Switching status 1-unsigned byte object 61 Byte5.1 percentage (0..100%)CWTU
10Button 1A - Switching status 1-signed byte object 61 Byte6.1 percentage (-128..127%)CWTU
10Button 1A - Switching status 2-unsigned bytes object 62 Bytes7.1 pulsesCWTU
10Button 1A - Switching status 2-signed bytes object 62 Bytes8.1 pulses differenceCWTU
10Button 1A - Switching status 2-bytes floating value object 62 Bytes9.1 temperature (°C)CWTU
11Button 1A - Switching status 1-bit object 71 Bit1.1 switchCWTU
11Button 1A - Switching status 2-bits object 72 Bit2.1 switch controlCWTU
11Button 1A - Switching status 1-unsigned byte object 71 Byte5.1 percentage (0..100%)CWTU
11Button 1A - Switching status 1-signed byte object 71 Byte6.1 percentage (-128..127%)CWTU
11Button 1A - Switching status 2-unsigned bytes object 72 Bytes7.1 pulsesCWTU
11Button 1A - Switching status 2-signed bytes object 72 Bytes8.1 pulses differenceCWTU
11Button 1A - Switching status 2-bytes floating value object 72 Bytes9.1 temperature (°C)CWTU
12Button 1A - Switching status 1-bit object 81 Bit1.1 switchCWTU
12Button 1A - Switching status 2-bits object 82 Bit2.1 switch controlCWTU
12Button 1A - Switching status 1-unsigned byte object 81 Byte5.1 percentage (0..100%)CWTU
12Button 1A - Switching status 1-signed byte object 81 Byte6.1 percentage (-128..127%)CWTU
12Button 1A - Switching status 2-unsigned bytes object 82 Bytes7.1 pulsesCWTU
12Button 1A - Switching status 2-signed bytes object 82 Bytes8.1 pulses differenceCWTU
12Button 1A - Switching status 2-bytes floating value object 82 Bytes9.1 temperature (°C)CWTU
13Button 1A - Switching command1 Bit1.1 switchCWTU
13Button 1A - Dedicated stop command1 Bit1.17 triggerCT
13Buttons 1 and 2 - Switching command1 Bit1.1 switchCWTU
13Buttons 1 and 2 - Dedicated stop command1 Bit1.17 triggerCT
14Buttons 1 and 2 - Dimming up / down / stop command4 Bit3.7 dimming controlCRT
14Button 1A - Dimming up / down / stop command4 Bit3.7 dimming controlCRT
15Button 1A - Stop-step up / down command1 Bit1.7 stepCT
15Buttons 1 and 2 - Stop-step up / down command1 Bit1.7 stepCT
16Buttons 1 and 2 - Move up / down command1 Bit1.8 up/downCT
16Button 1A - Move up / down command1 Bit1.8 up/downCT
17Button 1A - Scene number1 Byte17.1 scene numberCT
17Button 1A - Scene number1 ByteDPT.18CT
20Button 2A - Lock command1 Bit1.3 enableCW
21Button 2A - Switching status 1-bit object 11 Bit1.1 switchCWTU
21Button 2A - Switching status 2-bits object 12 Bit2.1 switch controlCWTU
21Button 2A - Switching status 1-unsigned byte object 11 Byte5.1 percentage (0..100%)CWTU
21Button 2A - Switching status 1-signed byte object 11 Byte6.1 percentage (-128..127%)CWTU
21Button 2A - Switching status 2-unsigned bytes object 12 Bytes7.1 pulsesCWTU
21Button 2A - Switching status 2-signed bytes object 12 Bytes8.1 pulses differenceCWTU
21Button 2A - Switching status 2-bytes floating value object 12 Bytes9.1 temperature (°C)CWTU
22Button 2A - Switching status 1-bit object 21 Bit1.1 switchCWTU
22Button 2A - Switching status 2-bits object 22 Bit2.1 switch controlCWTU
22Button 2A - Switching status 1-unsigned byte object 21 Byte5.1 percentage (0..100%)CWTU
22Button 2A - Switching status 1-signed byte object 21 Byte6.1 percentage (-128..127%)CWTU
22Button 2A - Switching status 2-unsigned bytes object 22 Bytes7.1 pulsesCWTU
22Button 2A - Switching status 2-signed bytes object 22 Bytes8.1 pulses differenceCWTU
22Button 2A - Switching status 2-bytes floating value object 22 Bytes9.1 temperature (°C)CWTU
23Button 2A - Switching status 1-bit object 31 Bit1.1 switchCWTU
23Button 2A - Switching status 2-bits object 32 Bit2.1 switch controlCWTU
23Button 2A - Switching status 1-unsigned byte object 31 Byte5.1 percentage (0..100%)CWTU
23Button 2A - Switching status 1-signed byte object 31 Byte6.1 percentage (-128..127%)CWTU
23Button 2A - Switching status 2-unsigned bytes object 32 Bytes7.1 pulsesCWTU
23Button 2A - Switching status 2-signed bytes object 32 Bytes8.1 pulses differenceCWTU
23Button 2A - Switching status 2-bytes floating value object 32 Bytes9.1 temperature (°C)CWTU
24Button 2A - Switching status 1-bit object 41 Bit1.1 switchCWTU
24Button 2A - Switching status 2-bits object 42 Bit2.1 switch controlCWTU
24Button 2A - Switching status 1-unsigned byte object 41 Byte5.1 percentage (0..100%)CWTU
24Button 2A - Switching status 1-signed byte object 41 Byte6.1 percentage (-128..127%)CWTU
24Button 2A - Switching status 2-unsigned bytes object 42 Bytes7.1 pulsesCWTU
24Button 2A - Switching status 2-signed bytes object 42 Bytes8.1 pulses differenceCWTU
24Button 2A - Switching status 2-bytes floating value object 42 Bytes9.1 temperature (°C)CWTU
25Button 2A - Switching status 1-bit object 51 Bit1.1 switchCWTU
25Button 2A - Switching status 2-bits object 52 Bit2.1 switch controlCWTU
25Button 2A - Switching status 1-unsigned byte object 51 Byte5.1 percentage (0..100%)CWTU
25Button 2A - Switching status 1-signed byte object 51 Byte6.1 percentage (-128..127%)CWTU
25Button 2A - Switching status 2-unsigned bytes object 52 Bytes7.1 pulsesCWTU
25Button 2A - Switching status 2-signed bytes object 52 Bytes8.1 pulses differenceCWTU
25Button 2A - Switching status 2-bytes floating value object 52 Bytes9.1 temperature (°C)CWTU
26Button 2A - Switching status 1-bit object 61 Bit1.1 switchCWTU
26Button 2A - Switching status 2-bits object 62 Bit2.1 switch controlCWTU
26Button 2A - Switching status 1-unsigned byte object 61 Byte5.1 percentage (0..100%)CWTU
26Button 2A - Switching status 1-signed byte object 61 Byte6.1 percentage (-128..127%)CWTU
26Button 2A - Switching status 2-unsigned bytes object 62 Bytes7.1 pulsesCWTU
26Button 2A - Switching status 2-signed bytes object 62 Bytes8.1 pulses differenceCWTU
26Button 2A - Switching status 2-bytes floating value object 62 Bytes9.1 temperature (°C)CWTU
27Button 2A - Switching status 1-bit object 71 Bit1.1 switchCWTU
27Button 2A - Switching status 2-bits object 72 Bit2.1 switch controlCWTU
27Button 2A - Switching status 1-unsigned byte object 71 Byte5.1 percentage (0..100%)CWTU
27Button 2A - Switching status 1-signed byte object 71 Byte6.1 percentage (-128..127%)CWTU
27Button 2A - Switching status 2-unsigned bytes object 72 Bytes7.1 pulsesCWTU
27Button 2A - Switching status 2-signed bytes object 72 Bytes8.1 pulses differenceCWTU
27Button 2A - Switching status 2-bytes floating value object 72 Bytes9.1 temperature (°C)CWTU
28Button 2A - Switching status 1-bit object 81 Bit1.1 switchCWTU
28Button 2A - Switching status 2-bits object 82 Bit2.1 switch controlCWTU
28Button 2A - Switching status 1-unsigned byte object 81 Byte5.1 percentage (0..100%)CWTU
28Button 2A - Switching status 1-signed byte object 81 Byte6.1 percentage (-128..127%)CWTU
28Button 2A - Switching status 2-unsigned bytes object 82 Bytes7.1 pulsesCWTU
28Button 2A - Switching status 2-signed bytes object 82 Bytes8.1 pulses differenceCWTU
28Button 2A - Switching status 2-bytes floating value object 82 Bytes9.1 temperature (°C)CWTU
29Button 2A - Switching command1 Bit1.1 switchCWTU
29Button 2A - Dedicated stop command1 Bit1.17 triggerCT
30Button 2A - Dimming up / down / stop command4 Bit3.7 dimming controlCRT
31Button 2A - Stop-step up / down command1 Bit1.7 stepCT
32Button 2A - Move up / down command1 Bit1.8 up/downCT
33Button 2A - Scene number1 Byte17.1 scene numberCT
33Button 2A - Scene number1 ByteDPT.18CT
36Button 3A - Lock command1 Bit1.3 enableCW
36Buttons 3 and 4 - Lock command1 Bit1.3 enableCW
37Button 3A - Switching status 1-bit object 11 Bit1.1 switchCWTU
37Button 3A - Switching status 2-bits object 12 Bit2.1 switch controlCWTU
37Button 3A - Switching status 1-unsigned byte object 11 Byte5.1 percentage (0..100%)CWTU
37Button 3A - Switching status 1-signed byte object 11 Byte6.1 percentage (-128..127%)CWTU
37Button 3A - Switching status 2-unsigned bytes object 12 Bytes7.1 pulsesCWTU
37Button 3A - Switching status 2-signed bytes object 12 Bytes8.1 pulses differenceCWTU
37Button 3A - Switching status 2-bytes floating value object 12 Bytes9.1 temperature (°C)CWTU
38Button 3A - Switching status 1-bit object 21 Bit1.1 switchCWTU
38Button 3A - Switching status 2-bits object 22 Bit2.1 switch controlCWTU
38Button 3A - Switching status 1-unsigned byte object 21 Byte5.1 percentage (0..100%)CWTU
38Button 3A - Switching status 1-signed byte object 21 Byte6.1 percentage (-128..127%)CWTU
38Button 3A - Switching status 2-unsigned bytes object 22 Bytes7.1 pulsesCWTU
38Button 3A - Switching status 2-signed bytes object 22 Bytes8.1 pulses differenceCWTU
38Button 3A - Switching status 2-bytes floating value object 22 Bytes9.1 temperature (°C)CWTU
39Button 3A - Switching status 1-bit object 31 Bit1.1 switchCWTU
39Button 3A - Switching status 2-bits object 32 Bit2.1 switch controlCWTU
39Button 3A - Switching status 1-unsigned byte object 31 Byte5.1 percentage (0..100%)CWTU
39Button 3A - Switching status 1-signed byte object 31 Byte6.1 percentage (-128..127%)CWTU
39Button 3A - Switching status 2-unsigned bytes object 32 Bytes7.1 pulsesCWTU
39Button 3A - Switching status 2-signed bytes object 32 Bytes8.1 pulses differenceCWTU
39Button 3A - Switching status 2-bytes floating value object 32 Bytes9.1 temperature (°C)CWTU
40Button 3A - Switching status 1-bit object 41 Bit1.1 switchCWTU
40Button 3A - Switching status 2-bits object 42 Bit2.1 switch controlCWTU
40Button 3A - Switching status 1-unsigned byte object 41 Byte5.1 percentage (0..100%)CWTU
40Button 3A - Switching status 1-signed byte object 41 Byte6.1 percentage (-128..127%)CWTU
40Button 3A - Switching status 2-unsigned bytes object 42 Bytes7.1 pulsesCWTU
40Button 3A - Switching status 2-signed bytes object 42 Bytes8.1 pulses differenceCWTU
40Button 3A - Switching status 2-bytes floating value object 42 Bytes9.1 temperature (°C)CWTU
41Button 3A - Switching status 1-bit object 51 Bit1.1 switchCWTU
41Button 3A - Switching status 2-bits object 52 Bit2.1 switch controlCWTU
41Button 3A - Switching status 1-unsigned byte object 51 Byte5.1 percentage (0..100%)CWTU
41Button 3A - Switching status 1-signed byte object 51 Byte6.1 percentage (-128..127%)CWTU
41Button 3A - Switching status 2-unsigned bytes object 52 Bytes7.1 pulsesCWTU
41Button 3A - Switching status 2-signed bytes object 52 Bytes8.1 pulses differenceCWTU
41Button 3A - Switching status 2-bytes floating value object 52 Bytes9.1 temperature (°C)CWTU
42Button 3A - Switching status 1-bit object 61 Bit1.1 switchCWTU
42Button 3A - Switching status 2-bits object 62 Bit2.1 switch controlCWTU
42Button 3A - Switching status 1-unsigned byte object 61 Byte5.1 percentage (0..100%)CWTU
42Button 3A - Switching status 1-signed byte object 61 Byte6.1 percentage (-128..127%)CWTU
42Button 3A - Switching status 2-unsigned bytes object 62 Bytes7.1 pulsesCWTU
42Button 3A - Switching status 2-signed bytes object 62 Bytes8.1 pulses differenceCWTU
42Button 3A - Switching status 2-bytes floating value object 62 Bytes9.1 temperature (°C)CWTU
43Button 3A - Switching status 1-bit object 71 Bit1.1 switchCWTU
43Button 3A - Switching status 2-bits object 72 Bit2.1 switch controlCWTU
43Button 3A - Switching status 1-unsigned byte object 71 Byte5.1 percentage (0..100%)CWTU
43Button 3A - Switching status 1-signed byte object 71 Byte6.1 percentage (-128..127%)CWTU
43Button 3A - Switching status 2-unsigned bytes object 72 Bytes7.1 pulsesCWTU
43Button 3A - Switching status 2-signed bytes object 72 Bytes8.1 pulses differenceCWTU
43Button 3A - Switching status 2-bytes floating value object 72 Bytes9.1 temperature (°C)CWTU
44Button 3A - Switching status 1-bit object 81 Bit1.1 switchCWTU
44Button 3A - Switching status 2-bits object 82 Bit2.1 switch controlCWTU
44Button 3A - Switching status 1-unsigned byte object 81 Byte5.1 percentage (0..100%)CWTU
44Button 3A - Switching status 1-signed byte object 81 Byte6.1 percentage (-128..127%)CWTU
44Button 3A - Switching status 2-unsigned bytes object 82 Bytes7.1 pulsesCWTU
44Button 3A - Switching status 2-signed bytes object 82 Bytes8.1 pulses differenceCWTU
44Button 3A - Switching status 2-bytes floating value object 82 Bytes9.1 temperature (°C)CWTU
45Button 3A - Switching command1 Bit1.1 switchCWTU
45Button 3A - Dedicated stop command1 Bit1.17 triggerCT
45Buttons 3 and 4 - Switching command1 Bit1.1 switchCWTU
45Buttons 3 and 4 - Dedicated stop command1 Bit1.17 triggerCT
46Button 3A - Dimming up / down / stop command4 Bit3.7 dimming controlCRT
46Buttons 3 and 4 - Dimming up / down / stop command4 Bit3.7 dimming controlCRT
47Button 3A - Stop-step up / down command1 Bit1.7 stepCT
47Buttons 3 and 4 - Stop-step up / down command1 Bit1.7 stepCT
48Button 3A - Move up / down command1 Bit1.8 up/downCT
48Buttons 3 and 4 - Move up / down command1 Bit1.8 up/downCT
49Button 3A - Scene number1 Byte17.1 scene numberCT
49Button 3A - Scene number1 ByteDPT.18CT
52Button 4A - Lock command1 Bit1.3 enableCW
53Button 4A - Switching status 1-bit object 11 Bit1.1 switchCWTU
53Button 4A - Switching status 2-bits object 12 Bit2.1 switch controlCWTU
53Button 4A - Switching status 1-unsigned byte object 11 Byte5.1 percentage (0..100%)CWTU
53Button 4A - Switching status 1-signed byte object 11 Byte6.1 percentage (-128..127%)CWTU
53Button 4A - Switching status 2-unsigned bytes object 12 Bytes7.1 pulsesCWTU
53Button 4A - Switching status 2-signed bytes object 12 Bytes8.1 pulses differenceCWTU
53Button 4A - Switching status 2-bytes floating value object 12 Bytes9.1 temperature (°C)CWTU
54Button 4A - Switching status 1-bit object 21 Bit1.1 switchCWTU
54Button 4A - Switching status 2-bits object 22 Bit2.1 switch controlCWTU
54Button 4A - Switching status 1-unsigned byte object 21 Byte5.1 percentage (0..100%)CWTU
54Button 4A - Switching status 1-signed byte object 21 Byte6.1 percentage (-128..127%)CWTU
54Button 4A - Switching status 2-unsigned bytes object 22 Bytes7.1 pulsesCWTU
54Button 4A - Switching status 2-signed bytes object 22 Bytes8.1 pulses differenceCWTU
54Button 4A - Switching status 2-bytes floating value object 22 Bytes9.1 temperature (°C)CWTU
55Button 4A - Switching status 1-bit object 31 Bit1.1 switchCWTU
55Button 4A - Switching status 2-bits object 32 Bit2.1 switch controlCWTU
55Button 4A - Switching status 1-unsigned byte object 31 Byte5.1 percentage (0..100%)CWTU
55Button 4A - Switching status 1-signed byte object 31 Byte6.1 percentage (-128..127%)CWTU
55Button 4A - Switching status 2-unsigned bytes object 32 Bytes7.1 pulsesCWTU
55Button 4A - Switching status 2-signed bytes object 32 Bytes8.1 pulses differenceCWTU
55Button 4A - Switching status 2-bytes floating value object 32 Bytes9.1 temperature (°C)CWTU
56Button 4A - Switching status 1-bit object 41 Bit1.1 switchCWTU
56Button 4A - Switching status 2-bits object 42 Bit2.1 switch controlCWTU
56Button 4A - Switching status 1-unsigned byte object 41 Byte5.1 percentage (0..100%)CWTU
56Button 4A - Switching status 1-signed byte object 41 Byte6.1 percentage (-128..127%)CWTU
56Button 4A - Switching status 2-unsigned bytes object 42 Bytes7.1 pulsesCWTU
56Button 4A - Switching status 2-signed bytes object 42 Bytes8.1 pulses differenceCWTU
56Button 4A - Switching status 2-bytes floating value object 42 Bytes9.1 temperature (°C)CWTU
57Button 4A - Switching status 1-bit object 51 Bit1.1 switchCWTU
57Button 4A - Switching status 2-bits object 52 Bit2.1 switch controlCWTU
57Button 4A - Switching status 1-unsigned byte object 51 Byte5.1 percentage (0..100%)CWTU
57Button 4A - Switching status 1-signed byte object 51 Byte6.1 percentage (-128..127%)CWTU
57Button 4A - Switching status 2-unsigned bytes object 52 Bytes7.1 pulsesCWTU
57Button 4A - Switching status 2-signed bytes object 52 Bytes8.1 pulses differenceCWTU
57Button 4A - Switching status 2-bytes floating value object 52 Bytes9.1 temperature (°C)CWTU
58Button 4A - Switching status 1-bit object 61 Bit1.1 switchCWTU
58Button 4A - Switching status 2-bits object 62 Bit2.1 switch controlCWTU
58Button 4A - Switching status 1-unsigned byte object 61 Byte5.1 percentage (0..100%)CWTU
58Button 4A - Switching status 1-signed byte object 61 Byte6.1 percentage (-128..127%)CWTU
58Button 4A - Switching status 2-unsigned bytes object 62 Bytes7.1 pulsesCWTU
58Button 4A - Switching status 2-signed bytes object 62 Bytes8.1 pulses differenceCWTU
58Button 4A - Switching status 2-bytes floating value object 62 Bytes9.1 temperature (°C)CWTU
59Button 4A - Switching status 1-bit object 71 Bit1.1 switchCWTU
59Button 4A - Switching status 2-bits object 72 Bit2.1 switch controlCWTU
59Button 4A - Switching status 1-unsigned byte object 71 Byte5.1 percentage (0..100%)CWTU
59Button 4A - Switching status 1-signed byte object 71 Byte6.1 percentage (-128..127%)CWTU
59Button 4A - Switching status 2-unsigned bytes object 72 Bytes7.1 pulsesCWTU
59Button 4A - Switching status 2-signed bytes object 72 Bytes8.1 pulses differenceCWTU
59Button 4A - Switching status 2-bytes floating value object 72 Bytes9.1 temperature (°C)CWTU
60Button 4A - Switching status 1-bit object 81 Bit1.1 switchCWTU
60Button 4A - Switching status 2-bits object 82 Bit2.1 switch controlCWTU
60Button 4A - Switching status 1-unsigned byte object 81 Byte5.1 percentage (0..100%)CWTU
60Button 4A - Switching status 1-signed byte object 81 Byte6.1 percentage (-128..127%)CWTU
60Button 4A - Switching status 2-unsigned bytes object 82 Bytes7.1 pulsesCWTU
60Button 4A - Switching status 2-signed bytes object 82 Bytes8.1 pulses differenceCWTU
60Button 4A - Switching status 2-bytes floating value object 82 Bytes9.1 temperature (°C)CWTU
61Button 4A - Switching command1 Bit1.1 switchCWTU
61Button 4A - Dedicated stop command1 Bit1.17 triggerCT
62Button 4A - Dimming up / down / stop command4 Bit3.7 dimming controlCRT
63Button 4A - Stop-step up / down command1 Bit1.7 stepCT
64Button 4A - Move up / down command1 Bit1.8 up/downCT
65Button 4A - Scene number1 Byte17.1 scene numberCT
65Button 4A - Scene number1 ByteDPT.18CT
68Button 1B - Lock command1 Bit1.3 enableCW
69Button 1B - Switching status 1-bit object 11 Bit1.1 switchCWTU
69Button 1B - Switching status 2-bits object 12 Bit2.1 switch controlCWTU
69Button 1B - Switching status 1-unsigned byte object 11 Byte5.1 percentage (0..100%)CWTU
69Button 1B - Switching status 1-signed byte object 11 Byte6.1 percentage (-128..127%)CWTU
69Button 1B - Switching status 2-unsigned bytes object 12 Bytes7.1 pulsesCWTU
69Button 1B - Switching status 2-signed bytes object 12 Bytes8.1 pulses differenceCWTU
69Button 1B - Switching status 2-bytes floating value object 12 Bytes9.1 temperature (°C)CWTU
70Button 1B - Switching status 1-bit object 21 Bit1.1 switchCWTU
70Button 1B - Switching status 2-bits object 22 Bit2.1 switch controlCWTU
70Button 1B - Switching status 1-unsigned byte object 21 Byte5.1 percentage (0..100%)CWTU
70Button 1B - Switching status 1-signed byte object 21 Byte6.1 percentage (-128..127%)CWTU
70Button 1B - Switching status 2-unsigned bytes object 22 Bytes7.1 pulsesCWTU
70Button 1B - Switching status 2-signed bytes object 22 Bytes8.1 pulses differenceCWTU
70Button 1B - Switching status 2-bytes floating value object 22 Bytes9.1 temperature (°C)CWTU
71Button 1B - Switching status 1-bit object 31 Bit1.1 switchCWTU
71Button 1B - Switching status 2-bits object 32 Bit2.1 switch controlCWTU
71Button 1B - Switching status 1-unsigned byte object 31 Byte5.1 percentage (0..100%)CWTU
71Button 1B - Switching status 1-signed byte object 31 Byte6.1 percentage (-128..127%)CWTU
71Button 1B - Switching status 2-unsigned bytes object 32 Bytes7.1 pulsesCWTU
71Button 1B - Switching status 2-signed bytes object 32 Bytes8.1 pulses differenceCWTU
71Button 1B - Switching status 2-bytes floating value object 32 Bytes9.1 temperature (°C)CWTU
72Button 1B - Switching status 1-bit object 41 Bit1.1 switchCWTU
72Button 1B - Switching status 2-bits object 42 Bit2.1 switch controlCWTU
72Button 1B - Switching status 1-unsigned byte object 41 Byte5.1 percentage (0..100%)CWTU
72Button 1B - Switching status 1-signed byte object 41 Byte6.1 percentage (-128..127%)CWTU
72Button 1B - Switching status 2-unsigned bytes object 42 Bytes7.1 pulsesCWTU
72Button 1B - Switching status 2-signed bytes object 42 Bytes8.1 pulses differenceCWTU
72Button 1B - Switching status 2-bytes floating value object 42 Bytes9.1 temperature (°C)CWTU
73Button 1B - Switching status 1-bit object 51 Bit1.1 switchCWTU
73Button 1B - Switching status 2-bits object 52 Bit2.1 switch controlCWTU
73Button 1B - Switching status 1-unsigned byte object 51 Byte5.1 percentage (0..100%)CWTU
73Button 1B - Switching status 1-signed byte object 51 Byte6.1 percentage (-128..127%)CWTU
73Button 1B - Switching status 2-unsigned bytes object 52 Bytes7.1 pulsesCWTU
73Button 1B - Switching status 2-signed bytes object 52 Bytes8.1 pulses differenceCWTU
73Button 1B - Switching status 2-bytes floating value object 52 Bytes9.1 temperature (°C)CWTU
74Button 1B - Switching status 1-bit object 61 Bit1.1 switchCWTU
74Button 1B - Switching status 2-bits object 62 Bit2.1 switch controlCWTU
74Button 1B - Switching status 1-unsigned byte object 61 Byte5.1 percentage (0..100%)CWTU
74Button 1B - Switching status 1-signed byte object 61 Byte6.1 percentage (-128..127%)CWTU
74Button 1B - Switching status 2-unsigned bytes object 62 Bytes7.1 pulsesCWTU
74Button 1B - Switching status 2-signed bytes object 62 Bytes8.1 pulses differenceCWTU
74Button 1B - Switching status 2-bytes floating value object 62 Bytes9.1 temperature (°C)CWTU
75Button 1B - Switching status 1-bit object 71 Bit1.1 switchCWTU
75Button 1B - Switching status 2-bits object 72 Bit2.1 switch controlCWTU
75Button 1B - Switching status 1-unsigned byte object 71 Byte5.1 percentage (0..100%)CWTU
75Button 1B - Switching status 1-signed byte object 71 Byte6.1 percentage (-128..127%)CWTU
75Button 1B - Switching status 2-unsigned bytes object 72 Bytes7.1 pulsesCWTU
75Button 1B - Switching status 2-signed bytes object 72 Bytes8.1 pulses differenceCWTU
75Button 1B - Switching status 2-bytes floating value object 72 Bytes9.1 temperature (°C)CWTU
76Button 1B - Switching status 1-bit object 81 Bit1.1 switchCWTU
76Button 1B - Switching status 2-bits object 82 Bit2.1 switch controlCWTU
76Button 1B - Switching status 1-unsigned byte object 81 Byte5.1 percentage (0..100%)CWTU
76Button 1B - Switching status 1-signed byte object 81 Byte6.1 percentage (-128..127%)CWTU
76Button 1B - Switching status 2-unsigned bytes object 82 Bytes7.1 pulsesCWTU
76Button 1B - Switching status 2-signed bytes object 82 Bytes8.1 pulses differenceCWTU
76Button 1B - Switching status 2-bytes floating value object 82 Bytes9.1 temperature (°C)CWTU
77Button 1B - Switching command1 Bit1.1 switchCWTU
77Button 1B - Dedicated stop command1 Bit1.17 triggerCT
78Button 1B - Dimming up / down / stop command4 Bit3.7 dimming controlCRT
79Button 1B - Stop-step up / down command1 Bit1.7 stepCT
80Button 1B - Move up / down command1 Bit1.8 up/downCT
81Button 1B - Scene number1 Byte17.1 scene numberCT
81Button 1B - Scene number1 ByteDPT.18CT
84Button 2B - Lock command1 Bit1.3 enableCW
85Button 2B - Switching status 1-bit object 11 Bit1.1 switchCWTU
85Button 2B - Switching status 2-bits object 12 Bit2.1 switch controlCWTU
85Button 2B - Switching status 1-unsigned byte object 11 Byte5.1 percentage (0..100%)CWTU
85Button 2B - Switching status 1-signed byte object 11 Byte6.1 percentage (-128..127%)CWTU
85Button 2B - Switching status 2-unsigned bytes object 12 Bytes7.1 pulsesCWTU
85Button 2B - Switching status 2-signed bytes object 12 Bytes8.1 pulses differenceCWTU
85Button 2B - Switching status 2-bytes floating value object 12 Bytes9.1 temperature (°C)CWTU
86Button 2B - Switching status 1-bit object 21 Bit1.1 switchCWTU
86Button 2B - Switching status 2-bits object 22 Bit2.1 switch controlCWTU
86Button 2B - Switching status 1-unsigned byte object 21 Byte5.1 percentage (0..100%)CWTU
86Button 2B - Switching status 1-signed byte object 21 Byte6.1 percentage (-128..127%)CWTU
86Button 2B - Switching status 2-unsigned bytes object 22 Bytes7.1 pulsesCWTU
86Button 2B - Switching status 2-signed bytes object 22 Bytes8.1 pulses differenceCWTU
86Button 2B - Switching status 2-bytes floating value object 22 Bytes9.1 temperature (°C)CWTU
87Button 2B - Switching status 1-bit object 31 Bit1.1 switchCWTU
87Button 2B - Switching status 2-bits object 32 Bit2.1 switch controlCWTU
87Button 2B - Switching status 1-unsigned byte object 31 Byte5.1 percentage (0..100%)CWTU
87Button 2B - Switching status 1-signed byte object 31 Byte6.1 percentage (-128..127%)CWTU
87Button 2B - Switching status 2-unsigned bytes object 32 Bytes7.1 pulsesCWTU
87Button 2B - Switching status 2-signed bytes object 32 Bytes8.1 pulses differenceCWTU
87Button 2B - Switching status 2-bytes floating value object 32 Bytes9.1 temperature (°C)CWTU
88Button 2B - Switching status 1-bit object 41 Bit1.1 switchCWTU
88Button 2B - Switching status 2-bits object 42 Bit2.1 switch controlCWTU
88Button 2B - Switching status 1-unsigned byte object 41 Byte5.1 percentage (0..100%)CWTU
88Button 2B - Switching status 1-signed byte object 41 Byte6.1 percentage (-128..127%)CWTU
88Button 2B - Switching status 2-unsigned bytes object 42 Bytes7.1 pulsesCWTU
88Button 2B - Switching status 2-signed bytes object 42 Bytes8.1 pulses differenceCWTU
88Button 2B - Switching status 2-bytes floating value object 42 Bytes9.1 temperature (°C)CWTU
89Button 2B - Switching status 1-bit object 51 Bit1.1 switchCWTU
89Button 2B - Switching status 2-bits object 52 Bit2.1 switch controlCWTU
89Button 2B - Switching status 1-unsigned byte object 51 Byte5.1 percentage (0..100%)CWTU
89Button 2B - Switching status 1-signed byte object 51 Byte6.1 percentage (-128..127%)CWTU
89Button 2B - Switching status 2-unsigned bytes object 52 Bytes7.1 pulsesCWTU
89Button 2B - Switching status 2-signed bytes object 52 Bytes8.1 pulses differenceCWTU
89Button 2B - Switching status 2-bytes floating value object 52 Bytes9.1 temperature (°C)CWTU
90Button 2B - Switching status 1-bit object 61 Bit1.1 switchCWTU
90Button 2B - Switching status 2-bits object 62 Bit2.1 switch controlCWTU
90Button 2B - Switching status 1-unsigned byte object 61 Byte5.1 percentage (0..100%)CWTU
90Button 2B - Switching status 1-signed byte object 61 Byte6.1 percentage (-128..127%)CWTU
90Button 2B - Switching status 2-unsigned bytes object 62 Bytes7.1 pulsesCWTU
90Button 2B - Switching status 2-signed bytes object 62 Bytes8.1 pulses differenceCWTU
90Button 2B - Switching status 2-bytes floating value object 62 Bytes9.1 temperature (°C)CWTU
91Button 2B - Switching status 1-bit object 71 Bit1.1 switchCWTU
91Button 2B - Switching status 2-bits object 72 Bit2.1 switch controlCWTU
91Button 2B - Switching status 1-unsigned byte object 71 Byte5.1 percentage (0..100%)CWTU
91Button 2B - Switching status 1-signed byte object 71 Byte6.1 percentage (-128..127%)CWTU
91Button 2B - Switching status 2-unsigned bytes object 72 Bytes7.1 pulsesCWTU
91Button 2B - Switching status 2-signed bytes object 72 Bytes8.1 pulses differenceCWTU
91Button 2B - Switching status 2-bytes floating value object 72 Bytes9.1 temperature (°C)CWTU
92Button 2B - Switching status 1-bit object 81 Bit1.1 switchCWTU
92Button 2B - Switching status 2-bits object 82 Bit2.1 switch controlCWTU
92Button 2B - Switching status 1-unsigned byte object 81 Byte5.1 percentage (0..100%)CWTU
92Button 2B - Switching status 1-signed byte object 81 Byte6.1 percentage (-128..127%)CWTU
92Button 2B - Switching status 2-unsigned bytes object 82 Bytes7.1 pulsesCWTU
92Button 2B - Switching status 2-signed bytes object 82 Bytes8.1 pulses differenceCWTU
92Button 2B - Switching status 2-bytes floating value object 82 Bytes9.1 temperature (°C)CWTU
93Button 2B - Switching command1 Bit1.1 switchCWTU
93Button 2B - Dedicated stop command1 Bit1.17 triggerCT
94Button 2B - Dimming up / down / stop command4 Bit3.7 dimming controlCRT
95Button 2B - Stop-step up / down command1 Bit1.7 stepCT
96Button 2B - Move up / down command1 Bit1.8 up/downCT
97Button 2B - Scene number1 Byte17.1 scene numberCT
97Button 2B - Scene number1 ByteDPT.18CT
100Button 3B - Lock command1 Bit1.3 enableCW
101Button 3B - Switching status 1-bit object 11 Bit1.1 switchCWTU
101Button 3B - Switching status 2-bits object 12 Bit2.1 switch controlCWTU
101Button 3B - Switching status 1-unsigned byte object 11 Byte5.1 percentage (0..100%)CWTU
101Button 3B - Switching status 1-signed byte object 11 Byte6.1 percentage (-128..127%)CWTU
101Button 3B - Switching status 2-unsigned bytes object 12 Bytes7.1 pulsesCWTU
101Button 3B - Switching status 2-signed bytes object 12 Bytes8.1 pulses differenceCWTU
101Button 3B - Switching status 2-bytes floating value object 12 Bytes9.1 temperature (°C)CWTU
102Button 3B - Switching status 1-bit object 21 Bit1.1 switchCWTU
102Button 3B - Switching status 2-bits object 22 Bit2.1 switch controlCWTU
102Button 3B - Switching status 1-unsigned byte object 21 Byte5.1 percentage (0..100%)CWTU
102Button 3B - Switching status 1-signed byte object 21 Byte6.1 percentage (-128..127%)CWTU
102Button 3B - Switching status 2-unsigned bytes object 22 Bytes7.1 pulsesCWTU
102Button 3B - Switching status 2-signed bytes object 22 Bytes8.1 pulses differenceCWTU
102Button 3B - Switching status 2-bytes floating value object 22 Bytes9.1 temperature (°C)CWTU
103Button 3B - Switching status 1-bit object 31 Bit1.1 switchCWTU
103Button 3B - Switching status 2-bits object 32 Bit2.1 switch controlCWTU
103Button 3B - Switching status 1-unsigned byte object 31 Byte5.1 percentage (0..100%)CWTU
103Button 3B - Switching status 1-signed byte object 31 Byte6.1 percentage (-128..127%)CWTU
103Button 3B - Switching status 2-unsigned bytes object 32 Bytes7.1 pulsesCWTU
103Button 3B - Switching status 2-signed bytes object 32 Bytes8.1 pulses differenceCWTU
103Button 3B - Switching status 2-bytes floating value object 32 Bytes9.1 temperature (°C)CWTU
104Button 3B - Switching status 1-bit object 41 Bit1.1 switchCWTU
104Button 3B - Switching status 2-bits object 42 Bit2.1 switch controlCWTU
104Button 3B - Switching status 1-unsigned byte object 41 Byte5.1 percentage (0..100%)CWTU
104Button 3B - Switching status 1-signed byte object 41 Byte6.1 percentage (-128..127%)CWTU
104Button 3B - Switching status 2-unsigned bytes object 42 Bytes7.1 pulsesCWTU
104Button 3B - Switching status 2-signed bytes object 42 Bytes8.1 pulses differenceCWTU
104Button 3B - Switching status 2-bytes floating value object 42 Bytes9.1 temperature (°C)CWTU
105Button 3B - Switching status 1-bit object 51 Bit1.1 switchCWTU
105Button 3B - Switching status 2-bits object 52 Bit2.1 switch controlCWTU
105Button 3B - Switching status 1-unsigned byte object 51 Byte5.1 percentage (0..100%)CWTU
105Button 3B - Switching status 1-signed byte object 51 Byte6.1 percentage (-128..127%)CWTU
105Button 3B - Switching status 2-unsigned bytes object 52 Bytes7.1 pulsesCWTU
105Button 3B - Switching status 2-signed bytes object 52 Bytes8.1 pulses differenceCWTU
105Button 3B - Switching status 2-bytes floating value object 52 Bytes9.1 temperature (°C)CWTU
106Button 3B - Switching status 1-bit object 61 Bit1.1 switchCWTU
106Button 3B - Switching status 2-bits object 62 Bit2.1 switch controlCWTU
106Button 3B - Switching status 1-unsigned byte object 61 Byte5.1 percentage (0..100%)CWTU
106Button 3B - Switching status 1-signed byte object 61 Byte6.1 percentage (-128..127%)CWTU
106Button 3B - Switching status 2-unsigned bytes object 62 Bytes7.1 pulsesCWTU
106Button 3B - Switching status 2-signed bytes object 62 Bytes8.1 pulses differenceCWTU
106Button 3B - Switching status 2-bytes floating value object 62 Bytes9.1 temperature (°C)CWTU
107Button 3B - Switching status 1-bit object 71 Bit1.1 switchCWTU
107Button 3B - Switching status 2-bits object 72 Bit2.1 switch controlCWTU
107Button 3B - Switching status 1-unsigned byte object 71 Byte5.1 percentage (0..100%)CWTU
107Button 3B - Switching status 1-signed byte object 71 Byte6.1 percentage (-128..127%)CWTU
107Button 3B - Switching status 2-unsigned bytes object 72 Bytes7.1 pulsesCWTU
107Button 3B - Switching status 2-signed bytes object 72 Bytes8.1 pulses differenceCWTU
107Button 3B - Switching status 2-bytes floating value object 72 Bytes9.1 temperature (°C)CWTU
108Button 3B - Switching status 1-bit object 81 Bit1.1 switchCWTU
108Button 3B - Switching status 2-bits object 82 Bit2.1 switch controlCWTU
108Button 3B - Switching status 1-unsigned byte object 81 Byte5.1 percentage (0..100%)CWTU
108Button 3B - Switching status 1-signed byte object 81 Byte6.1 percentage (-128..127%)CWTU
108Button 3B - Switching status 2-unsigned bytes object 82 Bytes7.1 pulsesCWTU
108Button 3B - Switching status 2-signed bytes object 82 Bytes8.1 pulses differenceCWTU
108Button 3B - Switching status 2-bytes floating value object 82 Bytes9.1 temperature (°C)CWTU
109Button 3B - Switching command1 Bit1.1 switchCWTU
109Button 3B - Dedicated stop command1 Bit1.17 triggerCT
110Button 3B - Dimming up / down / stop command4 Bit3.7 dimming controlCRT
111Button 3B - Stop-step up / down command1 Bit1.7 stepCT
112Button 3B - Move up / down command1 Bit1.8 up/downCT
113Button 3B - Scene number1 Byte17.1 scene numberCT
113Button 3B - Scene number1 ByteDPT.18CT
116Button 4B - Lock command1 Bit1.3 enableCW
117Button 4B - Switching status 1-bit object 11 Bit1.1 switchCWTU
117Button 4B - Switching status 2-bits object 12 Bit2.1 switch controlCWTU
117Button 4B - Switching status 1-unsigned byte object 11 Byte5.1 percentage (0..100%)CWTU
117Button 4B - Switching status 1-signed byte object 11 Byte6.1 percentage (-128..127%)CWTU
117Button 4B - Switching status 2-unsigned bytes object 12 Bytes7.1 pulsesCWTU
117Button 4B - Switching status 2-signed bytes object 12 Bytes8.1 pulses differenceCWTU
117Button 4B - Switching status 2-bytes floating value object 12 Bytes9.1 temperature (°C)CWTU
118Button 4B - Switching status 1-bit object 21 Bit1.1 switchCWTU
118Button 4B - Switching status 2-bits object 22 Bit2.1 switch controlCWTU
118Button 4B - Switching status 1-unsigned byte object 21 Byte5.1 percentage (0..100%)CWTU
118Button 4B - Switching status 1-signed byte object 21 Byte6.1 percentage (-128..127%)CWTU
118Button 4B - Switching status 2-unsigned bytes object 22 Bytes7.1 pulsesCWTU
118Button 4B - Switching status 2-signed bytes object 22 Bytes8.1 pulses differenceCWTU
118Button 4B - Switching status 2-bytes floating value object 22 Bytes9.1 temperature (°C)CWTU
119Button 4B - Switching status 1-bit object 31 Bit1.1 switchCWTU
119Button 4B - Switching status 2-bits object 32 Bit2.1 switch controlCWTU
119Button 4B - Switching status 1-unsigned byte object 31 Byte5.1 percentage (0..100%)CWTU
119Button 4B - Switching status 1-signed byte object 31 Byte6.1 percentage (-128..127%)CWTU
119Button 4B - Switching status 2-unsigned bytes object 32 Bytes7.1 pulsesCWTU
119Button 4B - Switching status 2-signed bytes object 32 Bytes8.1 pulses differenceCWTU
119Button 4B - Switching status 2-bytes floating value object 32 Bytes9.1 temperature (°C)CWTU
120Button 4B - Switching status 1-bit object 41 Bit1.1 switchCWTU
120Button 4B - Switching status 2-bits object 42 Bit2.1 switch controlCWTU
120Button 4B - Switching status 1-unsigned byte object 41 Byte5.1 percentage (0..100%)CWTU
120Button 4B - Switching status 1-signed byte object 41 Byte6.1 percentage (-128..127%)CWTU
120Button 4B - Switching status 2-unsigned bytes object 42 Bytes7.1 pulsesCWTU
120Button 4B - Switching status 2-signed bytes object 42 Bytes8.1 pulses differenceCWTU
120Button 4B - Switching status 2-bytes floating value object 42 Bytes9.1 temperature (°C)CWTU
121Button 4B - Switching status 1-bit object 51 Bit1.1 switchCWTU
121Button 4B - Switching status 2-bits object 52 Bit2.1 switch controlCWTU
121Button 4B - Switching status 1-unsigned byte object 51 Byte5.1 percentage (0..100%)CWTU
121Button 4B - Switching status 1-signed byte object 51 Byte6.1 percentage (-128..127%)CWTU
121Button 4B - Switching status 2-unsigned bytes object 52 Bytes7.1 pulsesCWTU
121Button 4B - Switching status 2-signed bytes object 52 Bytes8.1 pulses differenceCWTU
121Button 4B - Switching status 2-bytes floating value object 52 Bytes9.1 temperature (°C)CWTU
122Button 4B - Switching status 1-bit object 61 Bit1.1 switchCWTU
122Button 4B - Switching status 2-bits object 62 Bit2.1 switch controlCWTU
122Button 4B - Switching status 1-unsigned byte object 61 Byte5.1 percentage (0..100%)CWTU
122Button 4B - Switching status 1-signed byte object 61 Byte6.1 percentage (-128..127%)CWTU
122Button 4B - Switching status 2-unsigned bytes object 62 Bytes7.1 pulsesCWTU
122Button 4B - Switching status 2-signed bytes object 62 Bytes8.1 pulses differenceCWTU
122Button 4B - Switching status 2-bytes floating value object 62 Bytes9.1 temperature (°C)CWTU
123Button 4B - Switching status 1-bit object 71 Bit1.1 switchCWTU
123Button 4B - Switching status 2-bits object 72 Bit2.1 switch controlCWTU
123Button 4B - Switching status 1-unsigned byte object 71 Byte5.1 percentage (0..100%)CWTU
123Button 4B - Switching status 1-signed byte object 71 Byte6.1 percentage (-128..127%)CWTU
123Button 4B - Switching status 2-unsigned bytes object 72 Bytes7.1 pulsesCWTU
123Button 4B - Switching status 2-signed bytes object 72 Bytes8.1 pulses differenceCWTU
123Button 4B - Switching status 2-bytes floating value object 72 Bytes9.1 temperature (°C)CWTU
124Button 4B - Switching status 1-bit object 81 Bit1.1 switchCWTU
124Button 4B - Switching status 2-bits object 82 Bit2.1 switch controlCWTU
124Button 4B - Switching status 1-unsigned byte object 81 Byte5.1 percentage (0..100%)CWTU
124Button 4B - Switching status 1-signed byte object 81 Byte6.1 percentage (-128..127%)CWTU
124Button 4B - Switching status 2-unsigned bytes object 82 Bytes7.1 pulsesCWTU
124Button 4B - Switching status 2-signed bytes object 82 Bytes8.1 pulses differenceCWTU
124Button 4B - Switching status 2-bytes floating value object 82 Bytes9.1 temperature (°C)CWTU
125Button 4B - Switching command1 Bit1.1 switchCWTU
125Button 4B - Dedicated stop command1 Bit1.17 triggerCT
126Button 4B - Dimming up / down / stop command4 Bit3.7 dimming controlCRT
127Button 4B - Stop-step up / down command1 Bit1.7 stepCT
128Button 4B - Move up / down command1 Bit1.8 up/downCT
129Button 4B - Scene number1 Byte17.1 scene numberCT
129Button 4B - Scene number1 ByteDPT.18CT
132Proximity - Lock command1 Bit1.3 enableCW
133Proximity - Switching status 1-bit object 11 Bit1.1 switchCWTU
133Proximity - Switching status 2-bits object 12 Bit2.1 switch controlCWTU
133Proximity - Switching status 1-unsigned byte object 11 Byte5.1 percentage (0..100%)CWTU
133Proximity - Switching status 1-signed byte object 11 Byte6.1 percentage (-128..127%)CWTU
133Proximity - Switching status 2-unsigned bytes object 12 Bytes7.1 pulsesCWTU
133Proximity - Switching status 2-signed bytes object 12 Bytes8.1 pulses differenceCWTU
133Proximity - Switching status 2-bytes floating value object 12 Bytes9.1 temperature (°C)CWTU
134Proximity - Switching status 1-bit object 21 Bit1.1 switchCWTU
134Proximity - Switching status 2-bits object 22 Bit2.1 switch controlCWTU
134Proximity - Switching status 1-unsigned byte object 21 Byte5.1 percentage (0..100%)CWTU
134Proximity - Switching status 1-signed byte object 21 Byte6.1 percentage (-128..127%)CWTU
134Proximity - Switching status 2-unsigned bytes object 22 Bytes7.1 pulsesCWTU
134Proximity - Switching status 2-signed bytes object 22 Bytes8.1 pulses differenceCWTU
134Proximity - Switching status 2-bytes floating value object 22 Bytes9.1 temperature (°C)CWTU
135Proximity - Switching status 1-bit object 31 Bit1.1 switchCWTU
135Proximity - Switching status 2-bits object 32 Bit2.1 switch controlCWTU
135Proximity - Switching status 1-unsigned byte object 31 Byte5.1 percentage (0..100%)CWTU
135Proximity - Switching status 1-signed byte object 31 Byte6.1 percentage (-128..127%)CWTU
135Proximity - Switching status 2-unsigned bytes object 32 Bytes7.1 pulsesCWTU
135Proximity - Switching status 2-signed bytes object 32 Bytes8.1 pulses differenceCWTU
135Proximity - Switching status 2-bytes floating value object 32 Bytes9.1 temperature (°C)CWTU
136Proximity - Switching status 1-bit object 41 Bit1.1 switchCWTU
136Proximity - Switching status 2-bits object 42 Bit2.1 switch controlCWTU
136Proximity - Switching status 1-unsigned byte object 41 Byte5.1 percentage (0..100%)CWTU
136Proximity - Switching status 1-signed byte object 41 Byte6.1 percentage (-128..127%)CWTU
136Proximity - Switching status 2-unsigned bytes object 42 Bytes7.1 pulsesCWTU
136Proximity - Switching status 2-signed bytes object 42 Bytes8.1 pulses differenceCWTU
136Proximity - Switching status 2-bytes floating value object 42 Bytes9.1 temperature (°C)CWTU
137Proximity - Switching status 1-bit object 51 Bit1.1 switchCWTU
137Proximity - Switching status 2-bits object 52 Bit2.1 switch controlCWTU
137Proximity - Switching status 1-unsigned byte object 51 Byte5.1 percentage (0..100%)CWTU
137Proximity - Switching status 1-signed byte object 51 Byte6.1 percentage (-128..127%)CWTU
137Proximity - Switching status 2-unsigned bytes object 52 Bytes7.1 pulsesCWTU
137Proximity - Switching status 2-signed bytes object 52 Bytes8.1 pulses differenceCWTU
137Proximity - Switching status 2-bytes floating value object 52 Bytes9.1 temperature (°C)CWTU
138Proximity - Switching status 1-bit object 61 Bit1.1 switchCWTU
138Proximity - Switching status 2-bits object 62 Bit2.1 switch controlCWTU
138Proximity - Switching status 1-unsigned byte object 61 Byte5.1 percentage (0..100%)CWTU
138Proximity - Switching status 1-signed byte object 61 Byte6.1 percentage (-128..127%)CWTU
138Proximity - Switching status 2-unsigned bytes object 62 Bytes7.1 pulsesCWTU
138Proximity - Switching status 2-signed bytes object 62 Bytes8.1 pulses differenceCWTU
138Proximity - Switching status 2-bytes floating value object 62 Bytes9.1 temperature (°C)CWTU
139Proximity - Switching status 1-bit object 71 Bit1.1 switchCWTU
139Proximity - Switching status 2-bits object 72 Bit2.1 switch controlCWTU
139Proximity - Switching status 1-unsigned byte object 71 Byte5.1 percentage (0..100%)CWTU
139Proximity - Switching status 1-signed byte object 71 Byte6.1 percentage (-128..127%)CWTU
139Proximity - Switching status 2-unsigned bytes object 72 Bytes7.1 pulsesCWTU
139Proximity - Switching status 2-signed bytes object 72 Bytes8.1 pulses differenceCWTU
139Proximity - Switching status 2-bytes floating value object 72 Bytes9.1 temperature (°C)CWTU
140Proximity - Switching status 1-bit object 81 Bit1.1 switchCWTU
140Proximity - Switching status 2-bits object 82 Bit2.1 switch controlCWTU
140Proximity - Switching status 1-unsigned byte object 81 Byte5.1 percentage (0..100%)CWTU
140Proximity - Switching status 1-signed byte object 81 Byte6.1 percentage (-128..127%)CWTU
140Proximity - Switching status 2-unsigned bytes object 82 Bytes7.1 pulsesCWTU
140Proximity - Switching status 2-signed bytes object 82 Bytes8.1 pulses differenceCWTU
140Proximity - Switching status 2-bytes floating value object 82 Bytes9.1 temperature (°C)CWTU
148Led 1A - Command 2 unsigned bytes2 Bytes7.1 pulsesCWTU
148Led 1A - Command 1 bit1 Bit1.1 switchCWTU
148Led 1A - Command 2 bit2 Bit2.1 switch controlCWTU
148Led 1A - Command 1 unsigned byte1 Byte5.10 counter pulses (0..255)CWTU
148Led 1A - Command 1 signed byte1 Byte6.10 counter pulses (-128..127)CWTU
148Led 1A - Command 2 signed bytes2 Bytes8.1 pulses differenceCWTU
148Led 1A - Command 2 floating bytes2 Bytes9.1 temperature (°C)CWTU
149Led 2A - Command 1 bit1 Bit1.1 switchCWTU
149Led 2A - Command 2 bit2 Bit2.1 switch controlCWTU
149Led 2A - Command 1 signed byte1 Byte6.10 counter pulses (-128..127)CWTU
149Led 2A - Command 1 unsigned byte1 Byte5.10 counter pulses (0..255)CWTU
149Led 2A - Command 2 signed bytes2 Bytes8.1 pulses differenceCWTU
149Led 2A - Command 2 unsigned bytes2 Bytes7.1 pulsesCWTU
149Led 2A - Command 2 floating bytes2 Bytes9.1 temperature (°C)CWTU
150Led 3A - Command 1 bit1 Bit1.1 switchCWTU
150Led 3A - Command 2 bit2 Bit2.1 switch controlCWTU
150Led 3A - Command 1 signed byte1 Byte6.10 counter pulses (-128..127)CWTU
150Led 3A - Command 1 unsigned byte1 Byte5.10 counter pulses (0..255)CWTU
150Led 3A - Command 2 signed bytes2 Bytes8.1 pulses differenceCWTU
150Led 3A - Command 2 unsigned bytes2 Bytes7.1 pulsesCWTU
150Led 3A - Command 2 floating bytes2 Bytes9.1 temperature (°C)CWTU
151Led 4A - Command 1 bit1 Bit1.1 switchCWTU
151Led 4A - Command 2 bit2 Bit2.1 switch controlCWTU
151Led 4A - Command 1 signed byte1 Byte6.10 counter pulses (-128..127)CWTU
151Led 4A - Command 1 unsigned byte1 Byte5.10 counter pulses (0..255)CWTU
151Led 4A - Command 2 signed bytes2 Bytes8.1 pulses differenceCWTU
151Led 4A - Command 2 unsigned bytes2 Bytes7.1 pulsesCWTU
151Led 4A - Command 2 floating bytes2 Bytes9.1 temperature (°C)CWTU
152Led 1B - Command 1 bit1 Bit1.1 switchCWTU
152Led 1B - Command 2 bit2 Bit2.1 switch controlCWTU
152Led 1B - Command 1 signed byte1 Byte6.10 counter pulses (-128..127)CWTU
152Led 1B - Command 1 unsigned byte1 Byte5.10 counter pulses (0..255)CWTU
152Led 1B - Command 2 signed bytes2 Bytes8.1 pulses differenceCWTU
152Led 1B - Command 2 unsigned bytes2 Bytes7.1 pulsesCWTU
152Led 1B - Command 2 floating bytes2 Bytes9.1 temperature (°C)CWTU
153Led 2B - Command 1 bit1 Bit1.1 switchCWTU
153Led 2B - Command 2 bit2 Bit2.1 switch controlCWTU
153Led 2B - Command 1 signed byte1 Byte6.10 counter pulses (-128..127)CWTU
153Led 2B - Command 1 unsigned byte1 Byte5.10 counter pulses (0..255)CWTU
153Led 2B - Command 2 signed bytes2 Bytes8.1 pulses differenceCWTU
153Led 2B - Command 2 unsigned bytes2 Bytes7.1 pulsesCWTU
153Led 2B - Command 2 floating bytes2 Bytes9.1 temperature (°C)CWTU
154Led 3B - Command 1 bit1 Bit1.1 switchCWTU
154Led 3B - Command 2 bit2 Bit2.1 switch controlCWTU
154Led 3B - Command 1 signed byte1 Byte6.10 counter pulses (-128..127)CWTU
154Led 3B - Command 1 unsigned byte1 Byte5.10 counter pulses (0..255)CWTU
154Led 3B - Command 2 signed bytes2 Bytes8.1 pulses differenceCWTU
154Led 3B - Command 2 unsigned bytes2 Bytes7.1 pulsesCWTU
154Led 3B - Command 2 floating bytes2 Bytes9.1 temperature (°C)CWTU
155Led 4B - Command 1 bit1 Bit1.1 switchCWTU
155Led 4B - Command 2 bit2 Bit2.1 switch controlCWTU
155Led 4B - Command 1 signed byte1 Byte6.10 counter pulses (-128..127)CWTU
155Led 4B - Command 1 unsigned byte1 Byte5.10 counter pulses (0..255)CWTU
155Led 4B - Command 2 signed bytes2 Bytes8.1 pulses differenceCWTU
155Led 4B - Command 2 unsigned bytes2 Bytes7.1 pulsesCWTU
155Led 4B - Command 2 floating bytes2 Bytes9.1 temperature (°C)CWTU
156Logic function 1 - Input 11 Bit1.1 switchCWTU
157Logic function 1 - Input 21 Bit1.1 switchCWTU
158Logic function 1 - Input 31 Bit1.1 switchCWTU
159Logic function 1 - Input 41 Bit1.1 switchCWTU
160Logic function 1 - Output1 Bit1.1 switchCRT
161Logic function 2 - Input 11 Bit1.1 switchCWTU
162Logic function 2 - Input 21 Bit1.1 switchCWTU
163Logic function 2 - Input 31 Bit1.1 switchCWTU
164Logic function 2 - Input 41 Bit1.1 switchCWTU
165Logic function 2 - Output1 Bit1.1 switchCRT
166Logic function 3 - Input 11 Bit1.1 switchCWTU
167Logic function 3 - Input 21 Bit1.1 switchCWTU
168Logic function 3 - Input 31 Bit1.1 switchCWTU
169Logic function 3 - Input 41 Bit1.1 switchCWTU
170Logic function 3 - Output1 Bit1.1 switchCRT
171Logic function 4 - Input 11 Bit1.1 switchCWTU
172Logic function 4 - Input 21 Bit1.1 switchCWTU
173Logic function 4 - Input 31 Bit1.1 switchCWTU
174Logic function 4 - Input 41 Bit1.1 switchCWTU
175Logic function 4 - Output1 Bit1.1 switchCRT
176Logic function 5 - Input 11 Bit1.1 switchCWTU
177Logic function 5 - Input 21 Bit1.1 switchCWTU
178Logic function 5 - Input 31 Bit1.1 switchCWTU
179Logic function 5 - Input 41 Bit1.1 switchCWTU
180Logic function 5 - Output1 Bit1.1 switchCRT
181Logic function 6 - Input 11 Bit1.1 switchCWTU
182Logic function 6 - Input 21 Bit1.1 switchCWTU
183Logic function 6 - Input 31 Bit1.1 switchCWTU
184Logic function 6 - Input 41 Bit1.1 switchCWTU
185Logic function 6 - Output1 Bit1.1 switchCRT
186Logic function 7 - Input 11 Bit1.1 switchCWTU
187Logic function 7 - Input 21 Bit1.1 switchCWTU
188Logic function 7 - Input 31 Bit1.1 switchCWTU
189Logic function 7 - Input 41 Bit1.1 switchCWTU
190Logic function 7 - Output1 Bit1.1 switchCRT
191Logic function 8 - Input 11 Bit1.1 switchCWTU
192Logic function 8 - Input 21 Bit1.1 switchCWTU
193Logic function 8 - Input 31 Bit1.1 switchCWTU
194Logic function 8 - Input 41 Bit1.1 switchCWTU
195Logic function 8 - Output1 Bit1.1 switchCRT
196Temperature value2 Bytes9.1 temperature (°C)CRT
197Temperature threshold 1 - Switch1 Bit1.1 switchCRT
198Temperature threshold 1 - Lock1 Bit1.3 enableCW
199Temperature threshold 1 - Value (from bus)2 Bytes9.1 temperature (°C)CW
200Temperature threshold 2 - Switch1 Bit1.1 switchCRT
201Temperature threshold 2 - Lock1 Bit1.3 enableCW
202Temperature threshold 2 - Value (from bus)2 Bytes9.1 temperature (°C)CW
203Thermostat - Room temperature (from bus)2 Bytes9.1 temperature (°C)CWTU
204Thermostat - Humidity (2 bytes, from bus)2 Bytes9.7 humidity (%)CWTU
205Thermostat - Humidity (1 byte, from bus)1 Byte5.1 percentage (0..100%)CWTU
206Thermostat - Antistratification temperature (from bus)2 Bytes9.1 temperature (°C)CWTU
207Thermostat - Outdoor temperature (from bus)2 Bytes9.1 temperature (°C)CWTU
208Thermostat - Coil temperature (from bus)2 Bytes9.1 temperature (°C)CWTU
209Thermostat - Floor temperature (from bus)2 Bytes9.1 temperature (°C)CWTU
210Thermostat - Flow temperature (from bus)2 Bytes9.1 temperature (°C)CWTU
211Thermostat - Windows contact sensor 1 (from bus)1 Bit1.19 window/doorCWTU
212Thermostat - Windows contact sensor 2 (from bus)1 Bit1.19 window/doorCWTU
213Thermostat - Presence sensor 1 (from bus)1 Bit1.18 occupancyCWTU
214Thermostat - Presence sensor 2 (from bus)1 Bit1.18 occupancyCWTU
215Thermostat - Card holder contact (from bus)1 Bit1.18 occupancyCWTU
216Thermostat - Anticondensation (from bus)1 Bit1.1 switchCWTU
217Thermostat - Weighted temperature2 Bytes9.1 temperature (°C)CRT
218Thermostat - Heating/cooling status out1 Bit1.100 cooling/heatingCRT
219Thermostat - Heating/cooling status in1 Bit1.100 cooling/heatingCW
220Thermostat - HVAC mode in1 Byte20.102 HVAC modeCW
221Thermostat - HVAC forced mode in1 Byte20.102 HVAC modeCW
222Thermostat - HVAC mode out1 Byte20.102 HVAC modeCRT
223Thermostat - HVAC manual mode1 Byte20.102 HVAC modeCWTU
224Thermostat - Chrono active status1 Bit1.11 stateCRWTU
225Thermostat - Actual setpoint2 Bytes9.1 temperature (°C)CRT
226Thermostat - Manual setpoint2 Bytes9.1 temperature (°C)CW
227Thermostat - Comfort setpoint (heating)2 Bytes9.1 temperature (°C)CRWTU
227Thermostat - Input setpoint2 Bytes9.1 temperature (°C)CRWTU
228Thermostat - Comfort setpoint (cooling)2 Bytes9.1 temperature (°C)CRWTU
229Thermostat - Standby setpoint (heating)2 Bytes9.1 temperature (°C)CRWTU
229Thermostat - Standby offset (heating)2 Bytes9.2 temperature difference (K)CRWTU
230Thermostat - Standby setpoint (cooling)2 Bytes9.1 temperature (°C)CRWTU
230Thermostat - Standby offset (cooling)2 Bytes9.2 temperature difference (K)CRWTU
231Thermostat - Economy setpoint (heating)2 Bytes9.1 temperature (°C)CRWTU
231Thermostat - Economy offset (heating)2 Bytes9.2 temperature difference (K)CRWTU
232Thermostat - Economy setpoint (cooling)2 Bytes9.1 temperature (°C)CRWTU
232Thermostat - Economy offset (cooling)2 Bytes9.2 temperature difference (K)CRWTU
233Thermostat - Building protection setpoint (heating)2 Bytes9.1 temperature (°C)CRWTU
234Thermostat - Building protection setpoint (cooling)2 Bytes9.1 temperature (°C)CRWTU
235Thermostat - Room temperature controller status1 Bit1.3 enableCRT
236Thermostat - Heating out command1 Byte5.1 percentage (0..100%)CRT
236Thermostat - Heating out command1 Bit1.1 switchCRT
236Thermostat - Heating and cooling out command1 Bit1.1 switchCRT
236Thermostat - Heating and cooling out command1 Byte5.1 percentage (0..100%)CRT
237Thermostat - Cooling out command1 Byte5.1 percentage (0..100%)CRT
237Thermostat - Cooling out command1 Bit1.1 switchCRT
238Thermostat - Auxiliary heating output command1 Bit1.1 switchCRT
238Thermostat - Auxiliary heating and cooling output command1 Bit1.1 switchCRT
239Thermostat - Auxiliary cooling output command1 Bit1.1 switchCRT
240Thermostat - Auxiliary heating disable1 Bit1.3 enableCW
241Thermostat - Auxiliary cooling disable1 Bit1.3 enableCW
242Thermostat - Fan continuous speed1 Byte5.1 percentage (0..100%)CRT
243Thermostat - Fan speed 11 Bit1.1 switchCRT
244Thermostat - Fan speed 21 Bit1.1 switchCRT
245Thermostat - Fan speed 31 Bit1.1 switchCRT
246Thermostat - Fan control disable1 Bit1.2 booleanCW
247Thermostat - Alarm text14 Bytes16.0 Character String (ASCII)CRT
248Thermostat - Manual setpoint active status1 Bit1.11 stateCRWTU
249Thermostat - Fan manual speed1 Byte5.10 counter pulses (0..255)CRWTU
250Thermostat - Fan speed1 Byte5.10 counter pulses (0..255)CRT
251Thermostat - Fan manual active status1 Bit1.11 stateCRWTU
252Thermostat - Room temperature control alarm1 Bit1.5 alarmCRT
253Thermostat - Disable room temperature controller1 Bit1.1 switchCW
254Thermostat - Dew-point temperature2 Bytes9.1 temperature (°C)CRT
255Thermostat - Relative humidity setpoint for dehumidification2 Bytes9.7 humidity (%)CRWTU
256Thermostat - Relative humidity setpoint for humidification2 Bytes9.7 humidity (%)CRWTU
257Thermostat - Dehumidification command1 Bit1.1 switchCRT
258Thermostat - Dehumidification water battery command1 Bit1.1 switchCRT
259Thermostat - Dehumidification integration control1 Bit1.1 switchCRT
260Thermostat - Dehumidification control disable1 Bit1.2 booleanCW
261Thermostat - Humidification command1 Bit1.1 switchCRT
262Thermostat - Humidification control disable1 Bit1.2 booleanCW
263Thermostat - Anticondensation alarm1 Bit1.5 alarmCRT
264Thermostat - Thermal generator lock1 Bit1.5 alarmCW
265Thermostat - Building protection HVAC mode active1 Bit1.11 stateCRT
266Thermostat - Fan manual speed percentage1 Byte5.1 percentage (0..100%)CRT
267Thermostat - Fan manual speed off status1 Bit1.11 stateCRT
268Shift Register command 1 1 Byte5.10 counter pulses (0..255)CRT
269Shift Register command 2 1 Byte5.10 counter pulses (0..255)CRT
270Shift Register command 3 1 Byte5.10 counter pulses (0..255)CRT
271Shift Register command 41 Byte5.10 counter pulses (0..255)CRT
272Shift Register command 51 Byte5.10 counter pulses (0..255)CRT
273Shift Register command 61 Byte5.10 counter pulses (0..255)CRT
274Shift Register command 71 Byte5.10 counter pulses (0..255)CRT
275Shift Register command 81 Byte5.10 counter pulses (0..255)CRT
276Internal humidity sensor (2 byte) 2 BytesDPT.9CRT
276Internal humidity sensor (1 byte) 1 Byte5.1 percentage (0..100%)CRT
277Command LED standby 1 Bit1.1 switchCWI
278Command enable LED night mode 1 Bit1.3 enableCWI
279Command LED brightness top side 1 Byte5.1 percentage (0..100%)CWI
280Command LED brightness bottom side 1 Byte5.1 percentage (0..100%)CWI
281Command LED night brightness top side 1 Byte5.1 percentage (0..100%)CWI
282Command LED night brightness bottom side 1 Byte5.1 percentage (0..100%)CWI
Parameters (287)
ParameterTypeDefault
PID_HARDWARE_TYPE_PARAMETERlist
Signallistnot inverted
Cyclic reading eachlistno reading
Hysteresis positionlistbelow
Hysteresis positionlistabove
Delay for alarm signallist5 min
Thermostat functionlistheating
Heating - cooling cyclic sending intervallistno sending
Heating/cooling changeoverlistfrom bus
Analog sensors timeouttime300
Dehumidification functionlistdisabled
Humidification functionlistdisabled
Flow temperature (project)list14 °C
Digital sensors timeouttime300
Room temperaturelistdisabled
Relative humiditylistdisabled
Antistratification temperaturelistdisabled
Outdoor temperaturelistdisabled
Coil temperaturelistdisabled
Floor surface temperaturelistdisabled
Flow temperaturelistdisabled
Window contact 1listdisabled
Window contact 2listdisabled
Presence sensor 1listdisabled
Presence sensor 2listdisabled
Card holder contactlistdisabled
Humidity CO dimensionlist2 bytes
Cyclic sending intervallistno sending
Minimum change of value to send [K]float 0…50.5
Anticondensationlistdisabled
Relative weightlist50% / 50%
Setpoint cyclic sending intervallistno sending
Comfort temperature setpoint [°C]float 10…5021
Standby temperature offset [0.1 K]signedInt -50…-10-30
Economy temperature offset [0.1 K]signedInt -80…-10-50
Building protection temperature [°C]float 2…107
Control typelist2 points hysteresis
Command Communication Objectlistseparated
Hysteresislist0.3 K
PWM cycle timetime15
Proportional band [0.1K]unsignedInt 5…10040
Integral time [min]unsignedInt 0…25590
Valve protection functionlistdisabled
Frequencylistonce a week
Time intervallist10 s
Floor temperature limitationlistdisabled
Temperature limit [°C]float 20…4029
Auxiliary heatinglistdisabled
Communication objectlistseparated
Offset from setpointlist0.6 K
Disabled from buslistno
Cooling typelistfloor radiant panels
Anticondensation with probelistdisabled
Min control value [%]unsignedInt 0…3015
Min. change of value to send [%]unsignedInt 0…10010
Anticondensation hysteresis rangelist0.5 K
Auxiliary coolinglistdisabled
Control typelist1 speed
Threshold first speed [0.1K]unsignedInt 0…2550
Threshold second speed [0.1K]unsignedInt 0…25510
Threshold third speed [0.1K]unsignedInt 0…25520
Manual operationlistnot depending on the temperature
Hot startlistno
Use coil battery temperature sensor for dehumidificationlistno
Speed control hysteresislist0.3 K
Speed proportional band [0.1K]unsignedInt 5…10030
Min. change of value to send [%]unsignedInt 2…4010
Min. temp. to start ventilation [°C]unsignedInt 28…4028
Min. temp. to start dehumidif. [°C]unsignedInt 0…25510
Relative humidity setpoint [%]unsignedInt 0…10065
Relative humidity setpoint [%]list0.6 %
Max. temp. diff. to disable dehum. [°C]float 0…500.5
Forced speedlist1 speed
Forced speedunsignedInt 0…10020
Antistratification functionlistdisabled
Antistratification temp. differentiallist2.00 [K/m]
Hysteresislist0.5 K
Disable ventilation from buslistno
Signal from buslistnot inverted
Fan start delaylist0 s
Fan stop delaylist0 s
Dew-point temperaturelistdisabled
Min. change of value to send [K]list0.2 K
Windows contacts functionlistdisabled
Presence sensors functionlistdisabled
Presence sensors uselistcomfort extension
Thermostat modeslistcomfort - standby
Wait time to building protection modetime60
Absence time to switch HVAC modetime60
Card holder functionlistdisabled
On card insertion switch HVAC mode tolistcomfort
On card removal switch HVAC mode toliststandby
Activation delay on card insertiontime0
Activation delay on card removaltime0
Ventilation for auxiliary coolinglistdisabled
End of manual operationlistat first telegram from bus
Heating typelistradiators
Heating typelistfancoils
Humidity hysteresislist0.8 %
Subordinated to temperature controllistyes
Humidity setpointunsignedInt 20…8055
Integrationlistno
Dehumidification start delaytime300
Temperature difference for integrationlist1.5 °C
Hysteresis for integrationlist0.5 K
Disable dehumid. control from buslistno
Humidity setpointunsignedInt 20…8035
Disable humidification control from buslistno
Max control value [%]unsignedInt 70…10085
Active anticondensationlistdisabled
Transmission delay after mode changetime400
Channel 1listindependent or single
Channel 2listindependent or single
Delay after bus voltage recoverytime400
Button 1Alistenabled
Long press timetime80
Lock functionlistdisabled
Invert lock device signallistnot inverted
Lock after bus recoverylistno
Typelistsend values or sequences
Number of Communication ObjectsunsignedInt 1…81
Eventlistactivation / release
Behavior at lockinglistnone
Behavior at unlockinglistnone
Send cyclicallylistnone
Cyclic sending intervaltime120
Send delaytime0
Communication object dimensionlist1 bit value
Reaction to activationliston
Reaction to releaselistoff
Reaction to short pressliston
Reaction to long presslistoff
Reaction to activationlistenable on / down
Reaction to releaselistdisable
Reaction to short presslistenable on / down
Reaction to long presslistdisable
Reaction to activationlistsend value 1
Reaction to releaselistnone
Reaction to short presslistsend value 1
Reaction to long presslistnone
Value 1unsignedInt 0…2550
Value 2unsignedInt 0…2550
Value 1signedInt -128…1270
Value 2signedInt -128…1270
Value 1unsignedInt 0…655350
Value 2unsignedInt 0…655350
Value 1signedInt -32768…327670
Value 2signedInt -32768…327670
Value 1float -671088…6705970
Value 2float -671088…6705970
Toggle modelistenabled
Short / long actionlistoff / darker
Up / down actionlistup
Venetian blind modelistdisabled
Learning modelistdisabled
Scene activationlistsend first scene only
First scene numberunsignedInt 1…641
Second scene numberunsignedInt 1…642
Button 2Alistenabled
Typelistdimming
1 and 2 uselistA increases, B decreases
1 and 2 uselistA up, B down
1 and 2 uselistA on, B off
Button 3Alistenabled
Button 4Alistenabled
3 and 4 uselistA on, B off
3 and 4 uselistA increases, B decreases
3 and 4 uselistA up, B down
Reaction to long presslistdarker
Value 1unsignedInt 0…1000
Value 2unsignedInt 0…1000
Logic functionlistdisabled
Logic operationlistOR
Output cyclic transmission intervallistno sending
Logic object 1listdisabled
Logic object 2listdisabled
Logic object 3listdisabled
Logic object 4listdisabled
Logic object 1 negatedlistno
Logic object 2 negatedlistno
Logic object 3 negatedlistno
Logic object 4 negatedlistno
Logic object 1 read at startuplistno
Logic object 2 read at startuplistno
Logic object 3 read at startuplistno
Logic object 4 read at startuplistno
Logic object 1 default valuelistnone
Logic object 2 default valuelistnone
Logic object 3 default valuelistnone
Logic object 4 default valuelistnone
Output sendlistboth values
Output updatingliston value change
Technical alarmlistdisabled
Contact typelistNO (normally open)
Setpoint typelistsingle
Ventilation for auxiliary heatinglistdisabled
Threshold 1listnot active
Threshold 2listnot active
Value [°C]float 0…5045
Hysteresislist0.4 K
Temperature offsetlist0.0 °C
Thermostat functionalitieslistdisabled
Filter typelistmedium
Temperature setpoint [°C]float 10…5021
Temperature setpoint [°C]float 10…5023
Standby temperature offset [0.1 K]signedInt 10…5030
Economy temperature offset [0.1 K]signedInt 10…8050
Building protection temperature [°C]float 10…5036
Disable temperature controller from buslistno
Thermostat function after downloadlistno change
Neutral zone [0.1 K]signedInt 10…8020
Channel 3listindependent or single
Channel 4listindependent or single
Proximity sensorlistdisabled
Temperature sensorlistdisabled
Threshold value update from buslistno
Threshold lock enablelistno
Behaviour at locklistnone
Behaviour at bus recoverylistprevious state
Led 1A - Activationliston contact closed
Color Offcolor#00D4FF
Color Oncolor#00FF00
Off delaytime10
Blinking periodlistnone
Threshold typelist1 bit
Number of thresholdsunsignedInt 1…81
ValueunsignedInt 0…655350
Leds intensityunsignedInt 0…10050
Sensitivitylistmedium
Maximum standby intensityunsignedInt 0…10080
Send values or sequenceslistenabled
Reaction to presence detectedliston
Reaction to presence not detectedlistoff
Reaction to presence detectedlistenable on / down
Reaction to presence not detectedlistdisable
Reaction to presence detectedlistsend value 1
Reaction to presence not detectedlistnone
Colorcolor#00D4FF
Colorcolor#FFFF00
ValuesignedInt -32768…327670
ValueunsignedInt 0…2550
ValuesignedInt -128…1270
Valuefloat -671088…6705970
Product codelist----------
Button 1Blistenabled
Button 2Blistenabled
Button 3Blistenabled
Button 4Blistenabled
Leds intensity from buslistno
Backlight durationtime0
Led 2A - Activationliston contact closed
Led 3A - Activationliston contact closed
Led 4A - Activationliston contact closed
Led 1B - Activationliston contact closed
Led 2B - Activationliston contact closed
Led 3B - Activationliston contact closed
Led 4B - Activationliston contact closed
Standby temperature setpoint [°C]float 10…5018
Economy temperature setpoint [°C]float 10…5016
Standby temperature setpoint [°C]float 10…5026
Economy temperature setpoint [°C]float 10…5028
AlwaysYeslistyes
Shift Register maximum valueunsignedInt 0…2550
Shift Register minimum valueunsignedInt 0…2550
Shift Register step valuesignedInt -128…1270
Shift Register directionlistfrom lowest to highest value
Shift Register reset enablelistno reset
Shift Register Step valuesignedInt -128…1270
Humidity sensorlistdisabled
Humidity CO dimensionlist1 byte
Color standbycolor#FFFF00
Brightness top sideunsignedInt 0…10050
Brightness bottom sideunsignedInt 0…10050
Brightness night top sideunsignedInt 0…10050
Brightness night bottom sideunsignedInt 0…10050
Color choicelistPicker
Color OnlistAluminum Grey
Color OfflistAluminum Grey
Color standbylistAluminum Grey
ColorlistAluminum Grey
Humidity offsetsignedInt -10…100
Minimum change of value to sendunsignedInt 0…101
Cyclic sending eachlistNo sending
Function standbylistdisabled
Night functionlistdisabled
Side management from buslistdisabled
Enable brightness group objectslistdisabled

Version history

ApplicationApp noFingerprintFirst seenSizeFile
APERATP 0.2 latest$5241BE5A2026-11-25530 KBDownload
APERATP 0.1$5241A8B22026-11-25532 KBDownload

About this file

This is the official ETS product database for the Ekinex S.p.A. KNX ERA series pushbutton (EK-ERA-TP), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.

More from Ekinex S.p.A.

All Ekinex S.p.A. products