KNX Database
Ekinex S.p.A. EK-E20-TP-4TS-P Pushbutton 20venti 4-fold left with backlit text/symbols and proximity sensor

Pushbutton 20venti 4-fold left with backlit text/symbols and proximity sensor EK-E20-TP-4TS-P

Ekinex S.p.A. · Order number EK-E20-TP-4TS-P · Pushbuttons and displays

4/8-fold KNX 20venti series pushbutton

Download .knxprod APEKE20TP 0.2 · 448 KB

Product

ManufacturerEkinex S.p.A.
Product namePushbutton 20venti 4-fold left with backlit text/symbols and proximity sensor
Order numberEK-E20-TP-4TS-P
Product text4/8-fold KNX 20venti series pushbutton
Hardware4/8-fold KNX 20venti series pushbutton
MediumTwisted Pair
Bus current (mA)17
Rail mountedNo
RegistrationCertified · 2020-10-22
Languagesen-US, de-DE, fr-FR, it-IT
Catalog entryM-00B6_H-00B600000047-1_HP-4532-02-D257_CI-EK.2DE20.2DTP.2D4TS.2DP-1
FingerprintD257
SHA-2563e1b37f5df6ba4aa70cf44abeccb79bcdf35aba873c2bcf55c62bc960b5028c4
First seen2026-11-25
Markets68 markets

Application program: APEKE20TP 0.2

Application number$4532
Version0.2
Mask versionMV-07B0 (System B)
KNX Data SecureNo
Minimum ETS version4.0
Parameters2556
Group objects754
Group objects (754)
NoNameFunctionSizeDPTFlags
1Technical alarm1 Bit1.5 alarmCW
2Max leds intensity percentage1 Byte5.1 percentage (0..100%)CW
3Proximity sensor1 Bit1.17 triggerCWTU
4Button 1 left - Lock command1 Bit1.3 enableCW
4Buttons 1 and 2 - Lock command1 Bit1.3 enableCW
5Button 1 left - Switching status 1-bit object 11 Bit1.1 switchCWTU
5Button 1 left - Switching status 2-bits object 12 Bit2.1 switch controlCWTU
5Button 1 left - Switching status 1-unsigned byte object 11 Byte5.1 percentage (0..100%)CWTU
5Button 1 left - Switching status 1-signed byte object 11 Byte6.1 percentage (-128..127%)CWTU
5Button 1 left - Switching status 2-unsigned bytes object 12 Bytes7.1 pulsesCWTU
5Button 1 left - Switching status 2-signed bytes object 12 Bytes8.1 pulses differenceCWTU
5Button 1 left - Switching status 2-bytes floating value object 12 Bytes9.1 temperature (°C)CWTU
6Button 1 left - Switching status 1-bit object 21 Bit1.1 switchCWTU
6Button 1 left - Switching status 2-bits object 22 Bit2.1 switch controlCWTU
6Button 1 left - Switching status 1-unsigned byte object 21 Byte5.1 percentage (0..100%)CWTU
6Button 1 left - Switching status 1-signed byte object 21 Byte6.1 percentage (-128..127%)CWTU
6Button 1 left - Switching status 2-unsigned bytes object 22 Bytes7.1 pulsesCWTU
6Button 1 left - Switching status 2-signed bytes object 22 Bytes8.1 pulses differenceCWTU
6Button 1 left - Switching status 2-bytes floating value object 22 Bytes9.1 temperature (°C)CWTU
7Button 1 left - Switching status 1-bit object 31 Bit1.1 switchCWTU
7Button 1 left - Switching status 2-bits object 32 Bit2.1 switch controlCWTU
7Button 1 left - Switching status 1-unsigned byte object 31 Byte5.1 percentage (0..100%)CWTU
7Button 1 left - Switching status 1-signed byte object 31 Byte6.1 percentage (-128..127%)CWTU
7Button 1 left - Switching status 2-unsigned bytes object 32 Bytes7.1 pulsesCWTU
7Button 1 left - Switching status 2-signed bytes object 32 Bytes8.1 pulses differenceCWTU
7Button 1 left - Switching status 2-bytes floating value object 32 Bytes9.1 temperature (°C)CWTU
8Button 1 left - Switching status 1-bit object 41 Bit1.1 switchCWTU
8Button 1 left - Switching status 2-bits object 42 Bit2.1 switch controlCWTU
8Button 1 left - Switching status 1-unsigned byte object 41 Byte5.1 percentage (0..100%)CWTU
8Button 1 left - Switching status 1-signed byte object 41 Byte6.1 percentage (-128..127%)CWTU
8Button 1 left - Switching status 2-unsigned bytes object 42 Bytes7.1 pulsesCWTU
8Button 1 left - Switching status 2-signed bytes object 42 Bytes8.1 pulses differenceCWTU
8Button 1 left - Switching status 2-bytes floating value object 42 Bytes9.1 temperature (°C)CWTU
9Button 1 left - Switching status 1-bit object 51 Bit1.1 switchCWTU
9Button 1 left - Switching status 2-bits object 52 Bit2.1 switch controlCWTU
9Button 1 left - Switching status 1-unsigned byte object 51 Byte5.1 percentage (0..100%)CWTU
9Button 1 left - Switching status 1-signed byte object 51 Byte6.1 percentage (-128..127%)CWTU
9Button 1 left - Switching status 2-unsigned bytes object 52 Bytes7.1 pulsesCWTU
9Button 1 left - Switching status 2-signed bytes object 52 Bytes8.1 pulses differenceCWTU
9Button 1 left - Switching status 2-bytes floating value object 52 Bytes9.1 temperature (°C)CWTU
10Button 1 left - Switching status 1-bit object 61 Bit1.1 switchCWTU
10Button 1 left - Switching status 2-bits object 62 Bit2.1 switch controlCWTU
10Button 1 left - Switching status 1-unsigned byte object 61 Byte5.1 percentage (0..100%)CWTU
10Button 1 left - Switching status 1-signed byte object 61 Byte6.1 percentage (-128..127%)CWTU
10Button 1 left - Switching status 2-unsigned bytes object 62 Bytes7.1 pulsesCWTU
10Button 1 left - Switching status 2-signed bytes object 62 Bytes8.1 pulses differenceCWTU
10Button 1 left - Switching status 2-bytes floating value object 62 Bytes9.1 temperature (°C)CWTU
11Button 1 left - Switching status 1-bit object 71 Bit1.1 switchCWTU
11Button 1 left - Switching status 2-bits object 72 Bit2.1 switch controlCWTU
11Button 1 left - Switching status 1-unsigned byte object 71 Byte5.1 percentage (0..100%)CWTU
11Button 1 left - Switching status 1-signed byte object 71 Byte6.1 percentage (-128..127%)CWTU
11Button 1 left - Switching status 2-unsigned bytes object 72 Bytes7.1 pulsesCWTU
11Button 1 left - Switching status 2-signed bytes object 72 Bytes8.1 pulses differenceCWTU
11Button 1 left - Switching status 2-bytes floating value object 72 Bytes9.1 temperature (°C)CWTU
12Button 1 left - Switching status 1-bit object 81 Bit1.1 switchCWTU
12Button 1 left - Switching status 2-bits object 82 Bit2.1 switch controlCWTU
12Button 1 left - Switching status 1-unsigned byte object 81 Byte5.1 percentage (0..100%)CWTU
12Button 1 left - Switching status 1-signed byte object 81 Byte6.1 percentage (-128..127%)CWTU
12Button 1 left - Switching status 2-unsigned bytes object 82 Bytes7.1 pulsesCWTU
12Button 1 left - Switching status 2-signed bytes object 82 Bytes8.1 pulses differenceCWTU
12Button 1 left - Switching status 2-bytes floating value object 82 Bytes9.1 temperature (°C)CWTU
13Button 1 left - Switching command1 Bit1.1 switchCWTU
13Button 1 left - Dedicated stop command1 Bit1.17 triggerCT
13Buttons 1 and 2 - Switching command1 Bit1.1 switchCWTU
13Buttons 1 and 2 - Dedicated stop command1 Bit1.17 triggerCT
14Buttons 1 and 2 - Dimming up / down / stop command4 Bit3.7 dimming controlCRT
14Button 1 left - Dimming up / down / stop command4 Bit3.7 dimming controlCRT
15Button 1 left - Stop-step up / down command1 Bit1.7 stepCT
15Buttons 1 and 2 - Stop-step up / down command1 Bit1.7 stepCT
16Buttons 1 and 2 - Move up / down command1 Bit1.8 up/downCT
16Button 1 left - Move up / down command1 Bit1.8 up/downCT
17Button 1 left - Scene number1 Byte17.1 scene numberCT
20Button 2 left - Lock command1 Bit1.3 enableCW
21Button 2 left - Switching status 1-bit object 11 Bit1.1 switchCWTU
21Button 2 left - Switching status 2-bits object 12 Bit2.1 switch controlCWTU
21Button 2 left - Switching status 1-unsigned byte object 11 Byte5.1 percentage (0..100%)CWTU
21Button 2 left - Switching status 1-signed byte object 11 Byte6.1 percentage (-128..127%)CWTU
21Button 2 left - Switching status 2-unsigned bytes object 12 Bytes7.1 pulsesCWTU
21Button 2 left - Switching status 2-signed bytes object 12 Bytes8.1 pulses differenceCWTU
21Button 2 left - Switching status 2-bytes floating value object 12 Bytes9.1 temperature (°C)CWTU
22Button 2 left - Switching status 1-bit object 21 Bit1.1 switchCWTU
22Button 2 left - Switching status 2-bits object 22 Bit2.1 switch controlCWTU
22Button 2 left - Switching status 1-unsigned byte object 21 Byte5.1 percentage (0..100%)CWTU
22Button 2 left - Switching status 1-signed byte object 21 Byte6.1 percentage (-128..127%)CWTU
22Button 2 left - Switching status 2-unsigned bytes object 22 Bytes7.1 pulsesCWTU
22Button 2 left - Switching status 2-signed bytes object 22 Bytes8.1 pulses differenceCWTU
22Button 2 left - Switching status 2-bytes floating value object 22 Bytes9.1 temperature (°C)CWTU
23Button 2 left - Switching status 1-bit object 31 Bit1.1 switchCWTU
23Button 2 left - Switching status 2-bits object 32 Bit2.1 switch controlCWTU
23Button 2 left - Switching status 1-unsigned byte object 31 Byte5.1 percentage (0..100%)CWTU
23Button 2 left - Switching status 1-signed byte object 31 Byte6.1 percentage (-128..127%)CWTU
23Button 2 left - Switching status 2-unsigned bytes object 32 Bytes7.1 pulsesCWTU
23Button 2 left - Switching status 2-signed bytes object 32 Bytes8.1 pulses differenceCWTU
23Button 2 left - Switching status 2-bytes floating value object 32 Bytes9.1 temperature (°C)CWTU
24Button 2 left - Switching status 1-bit object 41 Bit1.1 switchCWTU
24Button 2 left - Switching status 2-bits object 42 Bit2.1 switch controlCWTU
24Button 2 left - Switching status 1-unsigned byte object 41 Byte5.1 percentage (0..100%)CWTU
24Button 2 left - Switching status 1-signed byte object 41 Byte6.1 percentage (-128..127%)CWTU
24Button 2 left - Switching status 2-unsigned bytes object 42 Bytes7.1 pulsesCWTU
24Button 2 left - Switching status 2-signed bytes object 42 Bytes8.1 pulses differenceCWTU
24Button 2 left - Switching status 2-bytes floating value object 42 Bytes9.1 temperature (°C)CWTU
25Button 2 left - Switching status 1-bit object 51 Bit1.1 switchCWTU
25Button 2 left - Switching status 2-bits object 52 Bit2.1 switch controlCWTU
25Button 2 left - Switching status 1-unsigned byte object 51 Byte5.1 percentage (0..100%)CWTU
25Button 2 left - Switching status 1-signed byte object 51 Byte6.1 percentage (-128..127%)CWTU
25Button 2 left - Switching status 2-unsigned bytes object 52 Bytes7.1 pulsesCWTU
25Button 2 left - Switching status 2-signed bytes object 52 Bytes8.1 pulses differenceCWTU
25Button 2 left - Switching status 2-bytes floating value object 52 Bytes9.1 temperature (°C)CWTU
26Button 2 left - Switching status 1-bit object 61 Bit1.1 switchCWTU
26Button 2 left - Switching status 2-bits object 62 Bit2.1 switch controlCWTU
26Button 2 left - Switching status 1-unsigned byte object 61 Byte5.1 percentage (0..100%)CWTU
26Button 2 left - Switching status 1-signed byte object 61 Byte6.1 percentage (-128..127%)CWTU
26Button 2 left - Switching status 2-unsigned bytes object 62 Bytes7.1 pulsesCWTU
26Button 2 left - Switching status 2-signed bytes object 62 Bytes8.1 pulses differenceCWTU
26Button 2 left - Switching status 2-bytes floating value object 62 Bytes9.1 temperature (°C)CWTU
27Button 2 left - Switching status 1-bit object 71 Bit1.1 switchCWTU
27Button 2 left - Switching status 2-bits object 72 Bit2.1 switch controlCWTU
27Button 2 left - Switching status 1-unsigned byte object 71 Byte5.1 percentage (0..100%)CWTU
27Button 2 left - Switching status 1-signed byte object 71 Byte6.1 percentage (-128..127%)CWTU
27Button 2 left - Switching status 2-unsigned bytes object 72 Bytes7.1 pulsesCWTU
27Button 2 left - Switching status 2-signed bytes object 72 Bytes8.1 pulses differenceCWTU
27Button 2 left - Switching status 2-bytes floating value object 72 Bytes9.1 temperature (°C)CWTU
28Button 2 left - Switching status 1-bit object 81 Bit1.1 switchCWTU
28Button 2 left - Switching status 2-bits object 82 Bit2.1 switch controlCWTU
28Button 2 left - Switching status 1-unsigned byte object 81 Byte5.1 percentage (0..100%)CWTU
28Button 2 left - Switching status 1-signed byte object 81 Byte6.1 percentage (-128..127%)CWTU
28Button 2 left - Switching status 2-unsigned bytes object 82 Bytes7.1 pulsesCWTU
28Button 2 left - Switching status 2-signed bytes object 82 Bytes8.1 pulses differenceCWTU
28Button 2 left - Switching status 2-bytes floating value object 82 Bytes9.1 temperature (°C)CWTU
29Button 2 left - Switching command1 Bit1.1 switchCWTU
29Button 2 left - Dedicated stop command1 Bit1.17 triggerCT
30Button 2 left - Dimming up / down / stop command4 Bit3.7 dimming controlCRT
31Button 2 left - Stop-step up / down command1 Bit1.7 stepCT
32Button 2 left - Move up / down command1 Bit1.8 up/downCT
33Button 2 left - Scene number1 Byte17.1 scene numberCT
36Button 3 left - Lock command1 Bit1.3 enableCW
36Buttons 3 and 4 - Lock command1 Bit1.3 enableCW
37Button 3 left - Switching status 1-bit object 11 Bit1.1 switchCWTU
37Button 3 left - Switching status 2-bits object 12 Bit2.1 switch controlCWTU
37Button 3 left - Switching status 1-unsigned byte object 11 Byte5.1 percentage (0..100%)CWTU
37Button 3 left - Switching status 1-signed byte object 11 Byte6.1 percentage (-128..127%)CWTU
37Button 3 left - Switching status 2-unsigned bytes object 12 Bytes7.1 pulsesCWTU
37Button 3 left - Switching status 2-signed bytes object 12 Bytes8.1 pulses differenceCWTU
37Button 3 left - Switching status 2-bytes floating value object 12 Bytes9.1 temperature (°C)CWTU
38Button 3 left - Switching status 1-bit object 21 Bit1.1 switchCWTU
38Button 3 left - Switching status 2-bits object 22 Bit2.1 switch controlCWTU
38Button 3 left - Switching status 1-unsigned byte object 21 Byte5.1 percentage (0..100%)CWTU
38Button 3 left - Switching status 1-signed byte object 21 Byte6.1 percentage (-128..127%)CWTU
38Button 3 left - Switching status 2-unsigned bytes object 22 Bytes7.1 pulsesCWTU
38Button 3 left - Switching status 2-signed bytes object 22 Bytes8.1 pulses differenceCWTU
38Button 3 left - Switching status 2-bytes floating value object 22 Bytes9.1 temperature (°C)CWTU
39Button 3 left - Switching status 1-bit object 31 Bit1.1 switchCWTU
39Button 3 left - Switching status 2-bits object 32 Bit2.1 switch controlCWTU
39Button 3 left - Switching status 1-unsigned byte object 31 Byte5.1 percentage (0..100%)CWTU
39Button 3 left - Switching status 1-signed byte object 31 Byte6.1 percentage (-128..127%)CWTU
39Button 3 left - Switching status 2-unsigned bytes object 32 Bytes7.1 pulsesCWTU
39Button 3 left - Switching status 2-signed bytes object 32 Bytes8.1 pulses differenceCWTU
39Button 3 left - Switching status 2-bytes floating value object 32 Bytes9.1 temperature (°C)CWTU
40Button 3 left - Switching status 1-bit object 41 Bit1.1 switchCWTU
40Button 3 left - Switching status 2-bits object 42 Bit2.1 switch controlCWTU
40Button 3 left - Switching status 1-unsigned byte object 41 Byte5.1 percentage (0..100%)CWTU
40Button 3 left - Switching status 1-signed byte object 41 Byte6.1 percentage (-128..127%)CWTU
40Button 3 left - Switching status 2-unsigned bytes object 42 Bytes7.1 pulsesCWTU
40Button 3 left - Switching status 2-signed bytes object 42 Bytes8.1 pulses differenceCWTU
40Button 3 left - Switching status 2-bytes floating value object 42 Bytes9.1 temperature (°C)CWTU
41Button 3 left - Switching status 1-bit object 51 Bit1.1 switchCWTU
41Button 3 left - Switching status 2-bits object 52 Bit2.1 switch controlCWTU
41Button 3 left - Switching status 1-unsigned byte object 51 Byte5.1 percentage (0..100%)CWTU
41Button 3 left - Switching status 1-signed byte object 51 Byte6.1 percentage (-128..127%)CWTU
41Button 3 left - Switching status 2-unsigned bytes object 52 Bytes7.1 pulsesCWTU
41Button 3 left - Switching status 2-signed bytes object 52 Bytes8.1 pulses differenceCWTU
41Button 3 left - Switching status 2-bytes floating value object 52 Bytes9.1 temperature (°C)CWTU
42Button 3 left - Switching status 1-bit object 61 Bit1.1 switchCWTU
42Button 3 left - Switching status 2-bits object 62 Bit2.1 switch controlCWTU
42Button 3 left - Switching status 1-unsigned byte object 61 Byte5.1 percentage (0..100%)CWTU
42Button 3 left - Switching status 1-signed byte object 61 Byte6.1 percentage (-128..127%)CWTU
42Button 3 left - Switching status 2-unsigned bytes object 62 Bytes7.1 pulsesCWTU
42Button 3 left - Switching status 2-signed bytes object 62 Bytes8.1 pulses differenceCWTU
42Button 3 left - Switching status 2-bytes floating value object 62 Bytes9.1 temperature (°C)CWTU
43Button 3 left - Switching status 1-bit object 71 Bit1.1 switchCWTU
43Button 3 left - Switching status 2-bits object 72 Bit2.1 switch controlCWTU
43Button 3 left - Switching status 1-unsigned byte object 71 Byte5.1 percentage (0..100%)CWTU
43Button 3 left - Switching status 1-signed byte object 71 Byte6.1 percentage (-128..127%)CWTU
43Button 3 left - Switching status 2-unsigned bytes object 72 Bytes7.1 pulsesCWTU
43Button 3 left - Switching status 2-signed bytes object 72 Bytes8.1 pulses differenceCWTU
43Button 3 left - Switching status 2-bytes floating value object 72 Bytes9.1 temperature (°C)CWTU
44Button 3 left - Switching status 1-bit object 81 Bit1.1 switchCWTU
44Button 3 left - Switching status 2-bits object 82 Bit2.1 switch controlCWTU
44Button 3 left - Switching status 1-unsigned byte object 81 Byte5.1 percentage (0..100%)CWTU
44Button 3 left - Switching status 1-signed byte object 81 Byte6.1 percentage (-128..127%)CWTU
44Button 3 left - Switching status 2-unsigned bytes object 82 Bytes7.1 pulsesCWTU
44Button 3 left - Switching status 2-signed bytes object 82 Bytes8.1 pulses differenceCWTU
44Button 3 left - Switching status 2-bytes floating value object 82 Bytes9.1 temperature (°C)CWTU
45Button 3 left - Switching command1 Bit1.1 switchCWTU
45Button 3 left - Dedicated stop command1 Bit1.17 triggerCT
45Buttons 3 and 4 - Switching command1 Bit1.1 switchCWTU
45Buttons 3 and 4 - Dedicated stop command1 Bit1.17 triggerCT
46Button 3 left - Dimming up / down / stop command4 Bit3.7 dimming controlCRT
46Buttons 3 and 4 - Dimming up / down / stop command4 Bit3.7 dimming controlCRT
47Button 3 left - Stop-step up / down command1 Bit1.7 stepCT
47Buttons 3 and 4 - Stop-step up / down command1 Bit1.7 stepCT
48Button 3 left - Move up / down command1 Bit1.8 up/downCT
48Buttons 3 and 4 - Move up / down command1 Bit1.8 up/downCT
49Button 3 left - Scene number1 Byte17.1 scene numberCT
52Button 4 left - Lock command1 Bit1.3 enableCW
53Button 4 left - Switching status 1-bit object 11 Bit1.1 switchCWTU
53Button 4 left - Switching status 2-bits object 12 Bit2.1 switch controlCWTU
53Button 4 left - Switching status 1-unsigned byte object 11 Byte5.1 percentage (0..100%)CWTU
53Button 4 left - Switching status 1-signed byte object 11 Byte6.1 percentage (-128..127%)CWTU
53Button 4 left - Switching status 2-unsigned bytes object 12 Bytes7.1 pulsesCWTU
53Button 4 left - Switching status 2-signed bytes object 12 Bytes8.1 pulses differenceCWTU
53Button 4 left - Switching status 2-bytes floating value object 12 Bytes9.1 temperature (°C)CWTU
54Button 4 left - Switching status 1-bit object 21 Bit1.1 switchCWTU
54Button 4 left - Switching status 2-bits object 22 Bit2.1 switch controlCWTU
54Button 4 left - Switching status 1-unsigned byte object 21 Byte5.1 percentage (0..100%)CWTU
54Button 4 left - Switching status 1-signed byte object 21 Byte6.1 percentage (-128..127%)CWTU
54Button 4 left - Switching status 2-unsigned bytes object 22 Bytes7.1 pulsesCWTU
54Button 4 left - Switching status 2-signed bytes object 22 Bytes8.1 pulses differenceCWTU
54Button 4 left - Switching status 2-bytes floating value object 22 Bytes9.1 temperature (°C)CWTU
55Button 4 left - Switching status 1-bit object 31 Bit1.1 switchCWTU
55Button 4 left - Switching status 2-bits object 32 Bit2.1 switch controlCWTU
55Button 4 left - Switching status 1-unsigned byte object 31 Byte5.1 percentage (0..100%)CWTU
55Button 4 left - Switching status 1-signed byte object 31 Byte6.1 percentage (-128..127%)CWTU
55Button 4 left - Switching status 2-unsigned bytes object 32 Bytes7.1 pulsesCWTU
55Button 4 left - Switching status 2-signed bytes object 32 Bytes8.1 pulses differenceCWTU
55Button 4 left - Switching status 2-bytes floating value object 32 Bytes9.1 temperature (°C)CWTU
56Button 4 left - Switching status 1-bit object 41 Bit1.1 switchCWTU
56Button 4 left - Switching status 2-bits object 42 Bit2.1 switch controlCWTU
56Button 4 left - Switching status 1-unsigned byte object 41 Byte5.1 percentage (0..100%)CWTU
56Button 4 left - Switching status 1-signed byte object 41 Byte6.1 percentage (-128..127%)CWTU
56Button 4 left - Switching status 2-unsigned bytes object 42 Bytes7.1 pulsesCWTU
56Button 4 left - Switching status 2-signed bytes object 42 Bytes8.1 pulses differenceCWTU
56Button 4 left - Switching status 2-bytes floating value object 42 Bytes9.1 temperature (°C)CWTU
57Button 4 left - Switching status 1-bit object 51 Bit1.1 switchCWTU
57Button 4 left - Switching status 2-bits object 52 Bit2.1 switch controlCWTU
57Button 4 left - Switching status 1-unsigned byte object 51 Byte5.1 percentage (0..100%)CWTU
57Button 4 left - Switching status 1-signed byte object 51 Byte6.1 percentage (-128..127%)CWTU
57Button 4 left - Switching status 2-unsigned bytes object 52 Bytes7.1 pulsesCWTU
57Button 4 left - Switching status 2-signed bytes object 52 Bytes8.1 pulses differenceCWTU
57Button 4 left - Switching status 2-bytes floating value object 52 Bytes9.1 temperature (°C)CWTU
58Button 4 left - Switching status 1-bit object 61 Bit1.1 switchCWTU
58Button 4 left - Switching status 2-bits object 62 Bit2.1 switch controlCWTU
58Button 4 left - Switching status 1-unsigned byte object 61 Byte5.1 percentage (0..100%)CWTU
58Button 4 left - Switching status 1-signed byte object 61 Byte6.1 percentage (-128..127%)CWTU
58Button 4 left - Switching status 2-unsigned bytes object 62 Bytes7.1 pulsesCWTU
58Button 4 left - Switching status 2-signed bytes object 62 Bytes8.1 pulses differenceCWTU
58Button 4 left - Switching status 2-bytes floating value object 62 Bytes9.1 temperature (°C)CWTU
59Button 4 left - Switching status 1-bit object 71 Bit1.1 switchCWTU
59Button 4 left - Switching status 2-bits object 72 Bit2.1 switch controlCWTU
59Button 4 left - Switching status 1-unsigned byte object 71 Byte5.1 percentage (0..100%)CWTU
59Button 4 left - Switching status 1-signed byte object 71 Byte6.1 percentage (-128..127%)CWTU
59Button 4 left - Switching status 2-unsigned bytes object 72 Bytes7.1 pulsesCWTU
59Button 4 left - Switching status 2-signed bytes object 72 Bytes8.1 pulses differenceCWTU
59Button 4 left - Switching status 2-bytes floating value object 72 Bytes9.1 temperature (°C)CWTU
60Button 4 left - Switching status 1-bit object 81 Bit1.1 switchCWTU
60Button 4 left - Switching status 2-bits object 82 Bit2.1 switch controlCWTU
60Button 4 left - Switching status 1-unsigned byte object 81 Byte5.1 percentage (0..100%)CWTU
60Button 4 left - Switching status 1-signed byte object 81 Byte6.1 percentage (-128..127%)CWTU
60Button 4 left - Switching status 2-unsigned bytes object 82 Bytes7.1 pulsesCWTU
60Button 4 left - Switching status 2-signed bytes object 82 Bytes8.1 pulses differenceCWTU
60Button 4 left - Switching status 2-bytes floating value object 82 Bytes9.1 temperature (°C)CWTU
61Button 4 left - Switching command1 Bit1.1 switchCWTU
61Button 4 left - Dedicated stop command1 Bit1.17 triggerCT
62Button 4 left - Dimming up / down / stop command4 Bit3.7 dimming controlCRT
63Button 4 left - Stop-step up / down command1 Bit1.7 stepCT
64Button 4 left - Move up / down command1 Bit1.8 up/downCT
65Button 4 left - Scene number1 Byte17.1 scene numberCT
68Button 1 right - Lock command1 Bit1.3 enableCW
69Button 1 right - Switching status 1-bit object 11 Bit1.1 switchCWTU
69Button 1 right - Switching status 2-bits object 12 Bit2.1 switch controlCWTU
69Button 1 right - Switching status 1-unsigned byte object 11 Byte5.1 percentage (0..100%)CWTU
69Button 1 right - Switching status 1-signed byte object 11 Byte6.1 percentage (-128..127%)CWTU
69Button 1 right - Switching status 2-unsigned bytes object 12 Bytes7.1 pulsesCWTU
69Button 1 right - Switching status 2-signed bytes object 12 Bytes8.1 pulses differenceCWTU
69Button 1 right - Switching status 2-bytes floating value object 12 Bytes9.1 temperature (°C)CWTU
70Button 1 right - Switching status 1-bit object 21 Bit1.1 switchCWTU
70Button 1 right - Switching status 2-bits object 22 Bit2.1 switch controlCWTU
70Button 1 right - Switching status 1-unsigned byte object 21 Byte5.1 percentage (0..100%)CWTU
70Button 1 right - Switching status 1-signed byte object 21 Byte6.1 percentage (-128..127%)CWTU
70Button 1 right - Switching status 2-unsigned bytes object 22 Bytes7.1 pulsesCWTU
70Button 1 right - Switching status 2-signed bytes object 22 Bytes8.1 pulses differenceCWTU
70Button 1 right - Switching status 2-bytes floating value object 22 Bytes9.1 temperature (°C)CWTU
71Button 1 right - Switching status 1-bit object 31 Bit1.1 switchCWTU
71Button 1 right - Switching status 2-bits object 32 Bit2.1 switch controlCWTU
71Button 1 right - Switching status 1-unsigned byte object 31 Byte5.1 percentage (0..100%)CWTU
71Button 1 right - Switching status 1-signed byte object 31 Byte6.1 percentage (-128..127%)CWTU
71Button 1 right - Switching status 2-unsigned bytes object 32 Bytes7.1 pulsesCWTU
71Button 1 right - Switching status 2-signed bytes object 32 Bytes8.1 pulses differenceCWTU
71Button 1 right - Switching status 2-bytes floating value object 32 Bytes9.1 temperature (°C)CWTU
72Button 1 right - Switching status 1-bit object 41 Bit1.1 switchCWTU
72Button 1 right - Switching status 2-bits object 42 Bit2.1 switch controlCWTU
72Button 1 right - Switching status 1-unsigned byte object 41 Byte5.1 percentage (0..100%)CWTU
72Button 1 right - Switching status 1-signed byte object 41 Byte6.1 percentage (-128..127%)CWTU
72Button 1 right - Switching status 2-unsigned bytes object 42 Bytes7.1 pulsesCWTU
72Button 1 right - Switching status 2-signed bytes object 42 Bytes8.1 pulses differenceCWTU
72Button 1 right - Switching status 2-bytes floating value object 42 Bytes9.1 temperature (°C)CWTU
73Button 1 right - Switching status 1-bit object 51 Bit1.1 switchCWTU
73Button 1 right - Switching status 2-bits object 52 Bit2.1 switch controlCWTU
73Button 1 right - Switching status 1-unsigned byte object 51 Byte5.1 percentage (0..100%)CWTU
73Button 1 right - Switching status 1-signed byte object 51 Byte6.1 percentage (-128..127%)CWTU
73Button 1 right - Switching status 2-unsigned bytes object 52 Bytes7.1 pulsesCWTU
73Button 1 right - Switching status 2-signed bytes object 52 Bytes8.1 pulses differenceCWTU
73Button 1 right - Switching status 2-bytes floating value object 52 Bytes9.1 temperature (°C)CWTU
74Button 1 right - Switching status 1-bit object 61 Bit1.1 switchCWTU
74Button 1 right - Switching status 2-bits object 62 Bit2.1 switch controlCWTU
74Button 1 right - Switching status 1-unsigned byte object 61 Byte5.1 percentage (0..100%)CWTU
74Button 1 right - Switching status 1-signed byte object 61 Byte6.1 percentage (-128..127%)CWTU
74Button 1 right - Switching status 2-unsigned bytes object 62 Bytes7.1 pulsesCWTU
74Button 1 right - Switching status 2-signed bytes object 62 Bytes8.1 pulses differenceCWTU
74Button 1 right - Switching status 2-bytes floating value object 62 Bytes9.1 temperature (°C)CWTU
75Button 1 right - Switching status 1-bit object 71 Bit1.1 switchCWTU
75Button 1 right - Switching status 2-bits object 72 Bit2.1 switch controlCWTU
75Button 1 right - Switching status 1-unsigned byte object 71 Byte5.1 percentage (0..100%)CWTU
75Button 1 right - Switching status 1-signed byte object 71 Byte6.1 percentage (-128..127%)CWTU
75Button 1 right - Switching status 2-unsigned bytes object 72 Bytes7.1 pulsesCWTU
75Button 1 right - Switching status 2-signed bytes object 72 Bytes8.1 pulses differenceCWTU
75Button 1 right - Switching status 2-bytes floating value object 72 Bytes9.1 temperature (°C)CWTU
76Button 1 right - Switching status 1-bit object 81 Bit1.1 switchCWTU
76Button 1 right - Switching status 2-bits object 82 Bit2.1 switch controlCWTU
76Button 1 right - Switching status 1-unsigned byte object 81 Byte5.1 percentage (0..100%)CWTU
76Button 1 right - Switching status 1-signed byte object 81 Byte6.1 percentage (-128..127%)CWTU
76Button 1 right - Switching status 2-unsigned bytes object 82 Bytes7.1 pulsesCWTU
76Button 1 right - Switching status 2-signed bytes object 82 Bytes8.1 pulses differenceCWTU
76Button 1 right - Switching status 2-bytes floating value object 82 Bytes9.1 temperature (°C)CWTU
77Button 1 right - Switching command1 Bit1.1 switchCWTU
77Button 1 right - Dedicated stop command1 Bit1.17 triggerCT
78Button 1 right - Dimming up / down / stop command4 Bit3.7 dimming controlCRT
79Button 1 right - Stop-step up / down command1 Bit1.7 stepCT
80Button 1 right - Move up / down command1 Bit1.8 up/downCT
81Button 1 right - Scene number1 Byte17.1 scene numberCT
84Button 2 right - Lock command1 Bit1.3 enableCW
85Button 2 right - Switching status 1-bit object 11 Bit1.1 switchCWTU
85Button 2 right - Switching status 2-bits object 12 Bit2.1 switch controlCWTU
85Button 2 right - Switching status 1-unsigned byte object 11 Byte5.1 percentage (0..100%)CWTU
85Button 2 right - Switching status 1-signed byte object 11 Byte6.1 percentage (-128..127%)CWTU
85Button 2 right - Switching status 2-unsigned bytes object 12 Bytes7.1 pulsesCWTU
85Button 2 right - Switching status 2-signed bytes object 12 Bytes8.1 pulses differenceCWTU
85Button 2 right - Switching status 2-bytes floating value object 12 Bytes9.1 temperature (°C)CWTU
86Button 2 right - Switching status 1-bit object 21 Bit1.1 switchCWTU
86Button 2 right - Switching status 2-bits object 22 Bit2.1 switch controlCWTU
86Button 2 right - Switching status 1-unsigned byte object 21 Byte5.1 percentage (0..100%)CWTU
86Button 2 right - Switching status 1-signed byte object 21 Byte6.1 percentage (-128..127%)CWTU
86Button 2 right - Switching status 2-unsigned bytes object 22 Bytes7.1 pulsesCWTU
86Button 2 right - Switching status 2-signed bytes object 22 Bytes8.1 pulses differenceCWTU
86Button 2 right - Switching status 2-bytes floating value object 22 Bytes9.1 temperature (°C)CWTU
87Button 2 right - Switching status 1-bit object 31 Bit1.1 switchCWTU
87Button 2 right - Switching status 2-bits object 32 Bit2.1 switch controlCWTU
87Button 2 right - Switching status 1-unsigned byte object 31 Byte5.1 percentage (0..100%)CWTU
87Button 2 right - Switching status 1-signed byte object 31 Byte6.1 percentage (-128..127%)CWTU
87Button 2 right - Switching status 2-unsigned bytes object 32 Bytes7.1 pulsesCWTU
87Button 2 right - Switching status 2-signed bytes object 32 Bytes8.1 pulses differenceCWTU
87Button 2 right - Switching status 2-bytes floating value object 32 Bytes9.1 temperature (°C)CWTU
88Button 2 right - Switching status 1-bit object 41 Bit1.1 switchCWTU
88Button 2 right - Switching status 2-bits object 42 Bit2.1 switch controlCWTU
88Button 2 right - Switching status 1-unsigned byte object 41 Byte5.1 percentage (0..100%)CWTU
88Button 2 right - Switching status 1-signed byte object 41 Byte6.1 percentage (-128..127%)CWTU
88Button 2 right - Switching status 2-unsigned bytes object 42 Bytes7.1 pulsesCWTU
88Button 2 right - Switching status 2-signed bytes object 42 Bytes8.1 pulses differenceCWTU
88Button 2 right - Switching status 2-bytes floating value object 42 Bytes9.1 temperature (°C)CWTU
89Button 2 right - Switching status 1-bit object 51 Bit1.1 switchCWTU
89Button 2 right - Switching status 2-bits object 52 Bit2.1 switch controlCWTU
89Button 2 right - Switching status 1-unsigned byte object 51 Byte5.1 percentage (0..100%)CWTU
89Button 2 right - Switching status 1-signed byte object 51 Byte6.1 percentage (-128..127%)CWTU
89Button 2 right - Switching status 2-unsigned bytes object 52 Bytes7.1 pulsesCWTU
89Button 2 right - Switching status 2-signed bytes object 52 Bytes8.1 pulses differenceCWTU
89Button 2 right - Switching status 2-bytes floating value object 52 Bytes9.1 temperature (°C)CWTU
90Button 2 right - Switching status 1-bit object 61 Bit1.1 switchCWTU
90Button 2 right - Switching status 2-bits object 62 Bit2.1 switch controlCWTU
90Button 2 right - Switching status 1-unsigned byte object 61 Byte5.1 percentage (0..100%)CWTU
90Button 2 right - Switching status 1-signed byte object 61 Byte6.1 percentage (-128..127%)CWTU
90Button 2 right - Switching status 2-unsigned bytes object 62 Bytes7.1 pulsesCWTU
90Button 2 right - Switching status 2-signed bytes object 62 Bytes8.1 pulses differenceCWTU
90Button 2 right - Switching status 2-bytes floating value object 62 Bytes9.1 temperature (°C)CWTU
91Button 2 right - Switching status 1-bit object 71 Bit1.1 switchCWTU
91Button 2 right - Switching status 2-bits object 72 Bit2.1 switch controlCWTU
91Button 2 right - Switching status 1-unsigned byte object 71 Byte5.1 percentage (0..100%)CWTU
91Button 2 right - Switching status 1-signed byte object 71 Byte6.1 percentage (-128..127%)CWTU
91Button 2 right - Switching status 2-unsigned bytes object 72 Bytes7.1 pulsesCWTU
91Button 2 right - Switching status 2-signed bytes object 72 Bytes8.1 pulses differenceCWTU
91Button 2 right - Switching status 2-bytes floating value object 72 Bytes9.1 temperature (°C)CWTU
92Button 2 right - Switching status 1-bit object 81 Bit1.1 switchCWTU
92Button 2 right - Switching status 2-bits object 82 Bit2.1 switch controlCWTU
92Button 2 right - Switching status 1-unsigned byte object 81 Byte5.1 percentage (0..100%)CWTU
92Button 2 right - Switching status 1-signed byte object 81 Byte6.1 percentage (-128..127%)CWTU
92Button 2 right - Switching status 2-unsigned bytes object 82 Bytes7.1 pulsesCWTU
92Button 2 right - Switching status 2-signed bytes object 82 Bytes8.1 pulses differenceCWTU
92Button 2 right - Switching status 2-bytes floating value object 82 Bytes9.1 temperature (°C)CWTU
93Button 2 right - Switching command1 Bit1.1 switchCWTU
93Button 2 right - Dedicated stop command1 Bit1.17 triggerCT
94Button 2 right - Dimming up / down / stop command4 Bit3.7 dimming controlCRT
95Button 2 right - Stop-step up / down command1 Bit1.7 stepCT
96Button 2 right - Move up / down command1 Bit1.8 up/downCT
97Button 2 right - Scene number1 Byte17.1 scene numberCT
100Button 3 right - Lock command1 Bit1.3 enableCW
101Button 3 right - Switching status 1-bit object 11 Bit1.1 switchCWTU
101Button 3 right - Switching status 2-bits object 12 Bit2.1 switch controlCWTU
101Button 3 right - Switching status 1-unsigned byte object 11 Byte5.1 percentage (0..100%)CWTU
101Button 3 right - Switching status 1-signed byte object 11 Byte6.1 percentage (-128..127%)CWTU
101Button 3 right - Switching status 2-unsigned bytes object 12 Bytes7.1 pulsesCWTU
101Button 3 right - Switching status 2-signed bytes object 12 Bytes8.1 pulses differenceCWTU
101Button 3 right - Switching status 2-bytes floating value object 12 Bytes9.1 temperature (°C)CWTU
102Button 3 right - Switching status 1-bit object 21 Bit1.1 switchCWTU
102Button 3 right - Switching status 2-bits object 22 Bit2.1 switch controlCWTU
102Button 3 right - Switching status 1-unsigned byte object 21 Byte5.1 percentage (0..100%)CWTU
102Button 3 right - Switching status 1-signed byte object 21 Byte6.1 percentage (-128..127%)CWTU
102Button 3 right - Switching status 2-unsigned bytes object 22 Bytes7.1 pulsesCWTU
102Button 3 right - Switching status 2-signed bytes object 22 Bytes8.1 pulses differenceCWTU
102Button 3 right - Switching status 2-bytes floating value object 22 Bytes9.1 temperature (°C)CWTU
103Button 3 right - Switching status 1-bit object 31 Bit1.1 switchCWTU
103Button 3 right - Switching status 2-bits object 32 Bit2.1 switch controlCWTU
103Button 3 right - Switching status 1-unsigned byte object 31 Byte5.1 percentage (0..100%)CWTU
103Button 3 right - Switching status 1-signed byte object 31 Byte6.1 percentage (-128..127%)CWTU
103Button 3 right - Switching status 2-unsigned bytes object 32 Bytes7.1 pulsesCWTU
103Button 3 right - Switching status 2-signed bytes object 32 Bytes8.1 pulses differenceCWTU
103Button 3 right - Switching status 2-bytes floating value object 32 Bytes9.1 temperature (°C)CWTU
104Button 3 right - Switching status 1-bit object 41 Bit1.1 switchCWTU
104Button 3 right - Switching status 2-bits object 42 Bit2.1 switch controlCWTU
104Button 3 right - Switching status 1-unsigned byte object 41 Byte5.1 percentage (0..100%)CWTU
104Button 3 right - Switching status 1-signed byte object 41 Byte6.1 percentage (-128..127%)CWTU
104Button 3 right - Switching status 2-unsigned bytes object 42 Bytes7.1 pulsesCWTU
104Button 3 right - Switching status 2-signed bytes object 42 Bytes8.1 pulses differenceCWTU
104Button 3 right - Switching status 2-bytes floating value object 42 Bytes9.1 temperature (°C)CWTU
105Button 3 right - Switching status 1-bit object 51 Bit1.1 switchCWTU
105Button 3 right - Switching status 2-bits object 52 Bit2.1 switch controlCWTU
105Button 3 right - Switching status 1-unsigned byte object 51 Byte5.1 percentage (0..100%)CWTU
105Button 3 right - Switching status 1-signed byte object 51 Byte6.1 percentage (-128..127%)CWTU
105Button 3 right - Switching status 2-unsigned bytes object 52 Bytes7.1 pulsesCWTU
105Button 3 right - Switching status 2-signed bytes object 52 Bytes8.1 pulses differenceCWTU
105Button 3 right - Switching status 2-bytes floating value object 52 Bytes9.1 temperature (°C)CWTU
106Button 3 right - Switching status 1-bit object 61 Bit1.1 switchCWTU
106Button 3 right - Switching status 2-bits object 62 Bit2.1 switch controlCWTU
106Button 3 right - Switching status 1-unsigned byte object 61 Byte5.1 percentage (0..100%)CWTU
106Button 3 right - Switching status 1-signed byte object 61 Byte6.1 percentage (-128..127%)CWTU
106Button 3 right - Switching status 2-unsigned bytes object 62 Bytes7.1 pulsesCWTU
106Button 3 right - Switching status 2-signed bytes object 62 Bytes8.1 pulses differenceCWTU
106Button 3 right - Switching status 2-bytes floating value object 62 Bytes9.1 temperature (°C)CWTU
107Button 3 right - Switching status 1-bit object 71 Bit1.1 switchCWTU
107Button 3 right - Switching status 2-bits object 72 Bit2.1 switch controlCWTU
107Button 3 right - Switching status 1-unsigned byte object 71 Byte5.1 percentage (0..100%)CWTU
107Button 3 right - Switching status 1-signed byte object 71 Byte6.1 percentage (-128..127%)CWTU
107Button 3 right - Switching status 2-unsigned bytes object 72 Bytes7.1 pulsesCWTU
107Button 3 right - Switching status 2-signed bytes object 72 Bytes8.1 pulses differenceCWTU
107Button 3 right - Switching status 2-bytes floating value object 72 Bytes9.1 temperature (°C)CWTU
108Button 3 right - Switching status 1-bit object 81 Bit1.1 switchCWTU
108Button 3 right - Switching status 2-bits object 82 Bit2.1 switch controlCWTU
108Button 3 right - Switching status 1-unsigned byte object 81 Byte5.1 percentage (0..100%)CWTU
108Button 3 right - Switching status 1-signed byte object 81 Byte6.1 percentage (-128..127%)CWTU
108Button 3 right - Switching status 2-unsigned bytes object 82 Bytes7.1 pulsesCWTU
108Button 3 right - Switching status 2-signed bytes object 82 Bytes8.1 pulses differenceCWTU
108Button 3 right - Switching status 2-bytes floating value object 82 Bytes9.1 temperature (°C)CWTU
109Button 3 right - Switching command1 Bit1.1 switchCWTU
109Button 3 right - Dedicated stop command1 Bit1.17 triggerCT
110Button 3 right - Dimming up / down / stop command4 Bit3.7 dimming controlCRT
111Button 3 right - Stop-step up / down command1 Bit1.7 stepCT
112Button 3 right - Move up / down command1 Bit1.8 up/downCT
113Button 3 right - Scene number1 Byte17.1 scene numberCT
116Button 4 right - Lock command1 Bit1.3 enableCW
117Button 4 right - Switching status 1-bit object 11 Bit1.1 switchCWTU
117Button 4 right - Switching status 2-bits object 12 Bit2.1 switch controlCWTU
117Button 4 right - Switching status 1-unsigned byte object 11 Byte5.1 percentage (0..100%)CWTU
117Button 4 right - Switching status 1-signed byte object 11 Byte6.1 percentage (-128..127%)CWTU
117Button 4 right - Switching status 2-unsigned bytes object 12 Bytes7.1 pulsesCWTU
117Button 4 right - Switching status 2-signed bytes object 12 Bytes8.1 pulses differenceCWTU
117Button 4 right - Switching status 2-bytes floating value object 12 Bytes9.1 temperature (°C)CWTU
118Button 4 right - Switching status 1-bit object 21 Bit1.1 switchCWTU
118Button 4 right - Switching status 2-bits object 22 Bit2.1 switch controlCWTU
118Button 4 right - Switching status 1-unsigned byte object 21 Byte5.1 percentage (0..100%)CWTU
118Button 4 right - Switching status 1-signed byte object 21 Byte6.1 percentage (-128..127%)CWTU
118Button 4 right - Switching status 2-unsigned bytes object 22 Bytes7.1 pulsesCWTU
118Button 4 right - Switching status 2-signed bytes object 22 Bytes8.1 pulses differenceCWTU
118Button 4 right - Switching status 2-bytes floating value object 22 Bytes9.1 temperature (°C)CWTU
119Button 4 right - Switching status 1-bit object 31 Bit1.1 switchCWTU
119Button 4 right - Switching status 2-bits object 32 Bit2.1 switch controlCWTU
119Button 4 right - Switching status 1-unsigned byte object 31 Byte5.1 percentage (0..100%)CWTU
119Button 4 right - Switching status 1-signed byte object 31 Byte6.1 percentage (-128..127%)CWTU
119Button 4 right - Switching status 2-unsigned bytes object 32 Bytes7.1 pulsesCWTU
119Button 4 right - Switching status 2-signed bytes object 32 Bytes8.1 pulses differenceCWTU
119Button 4 right - Switching status 2-bytes floating value object 32 Bytes9.1 temperature (°C)CWTU
120Button 4 right - Switching status 1-bit object 41 Bit1.1 switchCWTU
120Button 4 right - Switching status 2-bits object 42 Bit2.1 switch controlCWTU
120Button 4 right - Switching status 1-unsigned byte object 41 Byte5.1 percentage (0..100%)CWTU
120Button 4 right - Switching status 1-signed byte object 41 Byte6.1 percentage (-128..127%)CWTU
120Button 4 right - Switching status 2-unsigned bytes object 42 Bytes7.1 pulsesCWTU
120Button 4 right - Switching status 2-signed bytes object 42 Bytes8.1 pulses differenceCWTU
120Button 4 right - Switching status 2-bytes floating value object 42 Bytes9.1 temperature (°C)CWTU
121Button 4 right - Switching status 1-bit object 51 Bit1.1 switchCWTU
121Button 4 right - Switching status 2-bits object 52 Bit2.1 switch controlCWTU
121Button 4 right - Switching status 1-unsigned byte object 51 Byte5.1 percentage (0..100%)CWTU
121Button 4 right - Switching status 1-signed byte object 51 Byte6.1 percentage (-128..127%)CWTU
121Button 4 right - Switching status 2-unsigned bytes object 52 Bytes7.1 pulsesCWTU
121Button 4 right - Switching status 2-signed bytes object 52 Bytes8.1 pulses differenceCWTU
121Button 4 right - Switching status 2-bytes floating value object 52 Bytes9.1 temperature (°C)CWTU
122Button 4 right - Switching status 1-bit object 61 Bit1.1 switchCWTU
122Button 4 right - Switching status 2-bits object 62 Bit2.1 switch controlCWTU
122Button 4 right - Switching status 1-unsigned byte object 61 Byte5.1 percentage (0..100%)CWTU
122Button 4 right - Switching status 1-signed byte object 61 Byte6.1 percentage (-128..127%)CWTU
122Button 4 right - Switching status 2-unsigned bytes object 62 Bytes7.1 pulsesCWTU
122Button 4 right - Switching status 2-signed bytes object 62 Bytes8.1 pulses differenceCWTU
122Button 4 right - Switching status 2-bytes floating value object 62 Bytes9.1 temperature (°C)CWTU
123Button 4 right - Switching status 1-bit object 71 Bit1.1 switchCWTU
123Button 4 right - Switching status 2-bits object 72 Bit2.1 switch controlCWTU
123Button 4 right - Switching status 1-unsigned byte object 71 Byte5.1 percentage (0..100%)CWTU
123Button 4 right - Switching status 1-signed byte object 71 Byte6.1 percentage (-128..127%)CWTU
123Button 4 right - Switching status 2-unsigned bytes object 72 Bytes7.1 pulsesCWTU
123Button 4 right - Switching status 2-signed bytes object 72 Bytes8.1 pulses differenceCWTU
123Button 4 right - Switching status 2-bytes floating value object 72 Bytes9.1 temperature (°C)CWTU
124Button 4 right - Switching status 1-bit object 81 Bit1.1 switchCWTU
124Button 4 right - Switching status 2-bits object 82 Bit2.1 switch controlCWTU
124Button 4 right - Switching status 1-unsigned byte object 81 Byte5.1 percentage (0..100%)CWTU
124Button 4 right - Switching status 1-signed byte object 81 Byte6.1 percentage (-128..127%)CWTU
124Button 4 right - Switching status 2-unsigned bytes object 82 Bytes7.1 pulsesCWTU
124Button 4 right - Switching status 2-signed bytes object 82 Bytes8.1 pulses differenceCWTU
124Button 4 right - Switching status 2-bytes floating value object 82 Bytes9.1 temperature (°C)CWTU
125Button 4 right - Switching command1 Bit1.1 switchCWTU
125Button 4 right - Dedicated stop command1 Bit1.17 triggerCT
126Button 4 right - Dimming up / down / stop command4 Bit3.7 dimming controlCRT
127Button 4 right - Stop-step up / down command1 Bit1.7 stepCT
128Button 4 right - Move up / down command1 Bit1.8 up/downCT
129Button 4 right - Scene number1 Byte17.1 scene numberCT
132Proximity - Lock command1 Bit1.3 enableCW
133Proximity - Switching status 1-bit object 11 Bit1.1 switchCWTU
133Proximity - Switching status 2-bits object 12 Bit2.1 switch controlCWTU
133Proximity - Switching status 1-unsigned byte object 11 Byte5.1 percentage (0..100%)CWTU
133Proximity - Switching status 1-signed byte object 11 Byte6.1 percentage (-128..127%)CWTU
133Proximity - Switching status 2-unsigned bytes object 12 Bytes7.1 pulsesCWTU
133Proximity - Switching status 2-signed bytes object 12 Bytes8.1 pulses differenceCWTU
133Proximity - Switching status 2-bytes floating value object 12 Bytes9.1 temperature (°C)CWTU
134Proximity - Switching status 1-bit object 21 Bit1.1 switchCWTU
134Proximity - Switching status 2-bits object 22 Bit2.1 switch controlCWTU
134Proximity - Switching status 1-unsigned byte object 21 Byte5.1 percentage (0..100%)CWTU
134Proximity - Switching status 1-signed byte object 21 Byte6.1 percentage (-128..127%)CWTU
134Proximity - Switching status 2-unsigned bytes object 22 Bytes7.1 pulsesCWTU
134Proximity - Switching status 2-signed bytes object 22 Bytes8.1 pulses differenceCWTU
134Proximity - Switching status 2-bytes floating value object 22 Bytes9.1 temperature (°C)CWTU
135Proximity - Switching status 1-bit object 31 Bit1.1 switchCWTU
135Proximity - Switching status 2-bits object 32 Bit2.1 switch controlCWTU
135Proximity - Switching status 1-unsigned byte object 31 Byte5.1 percentage (0..100%)CWTU
135Proximity - Switching status 1-signed byte object 31 Byte6.1 percentage (-128..127%)CWTU
135Proximity - Switching status 2-unsigned bytes object 32 Bytes7.1 pulsesCWTU
135Proximity - Switching status 2-signed bytes object 32 Bytes8.1 pulses differenceCWTU
135Proximity - Switching status 2-bytes floating value object 32 Bytes9.1 temperature (°C)CWTU
136Proximity - Switching status 1-bit object 41 Bit1.1 switchCWTU
136Proximity - Switching status 2-bits object 42 Bit2.1 switch controlCWTU
136Proximity - Switching status 1-unsigned byte object 41 Byte5.1 percentage (0..100%)CWTU
136Proximity - Switching status 1-signed byte object 41 Byte6.1 percentage (-128..127%)CWTU
136Proximity - Switching status 2-unsigned bytes object 42 Bytes7.1 pulsesCWTU
136Proximity - Switching status 2-signed bytes object 42 Bytes8.1 pulses differenceCWTU
136Proximity - Switching status 2-bytes floating value object 42 Bytes9.1 temperature (°C)CWTU
137Proximity - Switching status 1-bit object 51 Bit1.1 switchCWTU
137Proximity - Switching status 2-bits object 52 Bit2.1 switch controlCWTU
137Proximity - Switching status 1-unsigned byte object 51 Byte5.1 percentage (0..100%)CWTU
137Proximity - Switching status 1-signed byte object 51 Byte6.1 percentage (-128..127%)CWTU
137Proximity - Switching status 2-unsigned bytes object 52 Bytes7.1 pulsesCWTU
137Proximity - Switching status 2-signed bytes object 52 Bytes8.1 pulses differenceCWTU
137Proximity - Switching status 2-bytes floating value object 52 Bytes9.1 temperature (°C)CWTU
138Proximity - Switching status 1-bit object 61 Bit1.1 switchCWTU
138Proximity - Switching status 2-bits object 62 Bit2.1 switch controlCWTU
138Proximity - Switching status 1-unsigned byte object 61 Byte5.1 percentage (0..100%)CWTU
138Proximity - Switching status 1-signed byte object 61 Byte6.1 percentage (-128..127%)CWTU
138Proximity - Switching status 2-unsigned bytes object 62 Bytes7.1 pulsesCWTU
138Proximity - Switching status 2-signed bytes object 62 Bytes8.1 pulses differenceCWTU
138Proximity - Switching status 2-bytes floating value object 62 Bytes9.1 temperature (°C)CWTU
139Proximity - Switching status 1-bit object 71 Bit1.1 switchCWTU
139Proximity - Switching status 2-bits object 72 Bit2.1 switch controlCWTU
139Proximity - Switching status 1-unsigned byte object 71 Byte5.1 percentage (0..100%)CWTU
139Proximity - Switching status 1-signed byte object 71 Byte6.1 percentage (-128..127%)CWTU
139Proximity - Switching status 2-unsigned bytes object 72 Bytes7.1 pulsesCWTU
139Proximity - Switching status 2-signed bytes object 72 Bytes8.1 pulses differenceCWTU
139Proximity - Switching status 2-bytes floating value object 72 Bytes9.1 temperature (°C)CWTU
140Proximity - Switching status 1-bit object 81 Bit1.1 switchCWTU
140Proximity - Switching status 2-bits object 82 Bit2.1 switch controlCWTU
140Proximity - Switching status 1-unsigned byte object 81 Byte5.1 percentage (0..100%)CWTU
140Proximity - Switching status 1-signed byte object 81 Byte6.1 percentage (-128..127%)CWTU
140Proximity - Switching status 2-unsigned bytes object 82 Bytes7.1 pulsesCWTU
140Proximity - Switching status 2-signed bytes object 82 Bytes8.1 pulses differenceCWTU
140Proximity - Switching status 2-bytes floating value object 82 Bytes9.1 temperature (°C)CWTU
148Led 1 left - Command 2 unsigned bytes2 Bytes7.1 pulsesCWTU
148Led 1 left - Command 1 bit1 Bit1.1 switchCWTU
148Led 1 left - Command 2 bit2 Bit2.1 switch controlCWTU
148Led 1 left - Command 1 unsigned byte1 Byte5.10 counter pulses (0..255)CWTU
148Led 1 left - Command 1 signed byte1 Byte6.10 counter pulses (-128..127)CWTU
148Led 1 left - Command 2 signed bytes2 Bytes8.1 pulses differenceCWTU
148Led 1 left - Command 2 floating bytes2 Bytes9.1 temperature (°C)CWTU
149Led 2 left - Command 1 bit1 Bit1.1 switchCWTU
149Led 2 left - Command 2 bit2 Bit2.1 switch controlCWTU
149Led 2 left - Command 1 signed byte1 Byte6.10 counter pulses (-128..127)CWTU
149Led 2 left - Command 1 unsigned byte1 Byte5.10 counter pulses (0..255)CWTU
149Led 2 left - Command 2 signed bytes2 Bytes8.1 pulses differenceCWTU
149Led 2 left - Command 2 unsigned bytes2 Bytes7.1 pulsesCWTU
149Led 2 left - Command 2 floating bytes2 Bytes9.1 temperature (°C)CWTU
150Led 3 left - Command 1 bit1 Bit1.1 switchCWTU
150Led 3 left - Command 2 bit2 Bit2.1 switch controlCWTU
150Led 3 left - Command 1 signed byte1 Byte6.10 counter pulses (-128..127)CWTU
150Led 3 left - Command 1 unsigned byte1 Byte5.10 counter pulses (0..255)CWTU
150Led 3 left - Command 2 signed bytes2 Bytes8.1 pulses differenceCWTU
150Led 3 left - Command 2 unsigned bytes2 Bytes7.1 pulsesCWTU
150Led 3 left - Command 2 floating bytes2 Bytes9.1 temperature (°C)CWTU
151Led 4 left - Command 1 bit1 Bit1.1 switchCWTU
151Led 4 left - Command 2 bit2 Bit2.1 switch controlCWTU
151Led 4 left - Command 1 signed byte1 Byte6.10 counter pulses (-128..127)CWTU
151Led 4 left - Command 1 unsigned byte1 Byte5.10 counter pulses (0..255)CWTU
151Led 4 left - Command 2 signed bytes2 Bytes8.1 pulses differenceCWTU
151Led 4 left - Command 2 unsigned bytes2 Bytes7.1 pulsesCWTU
151Led 4 left - Command 2 floating bytes2 Bytes9.1 temperature (°C)CWTU
152Led 1 right - Command 1 bit1 Bit1.1 switchCWTU
152Led 1 right - Command 2 bit2 Bit2.1 switch controlCWTU
152Led 1 right - Command 1 signed byte1 Byte6.10 counter pulses (-128..127)CWTU
152Led 1 right - Command 1 unsigned byte1 Byte5.10 counter pulses (0..255)CWTU
152Led 1 right - Command 2 signed bytes2 Bytes8.1 pulses differenceCWTU
152Led 1 right - Command 2 unsigned bytes2 Bytes7.1 pulsesCWTU
152Led 1 right - Command 2 floating bytes2 Bytes9.1 temperature (°C)CWTU
153Led 2 right - Command 1 bit1 Bit1.1 switchCWTU
153Led 2 right - Command 2 bit2 Bit2.1 switch controlCWTU
153Led 2 right - Command 1 signed byte1 Byte6.10 counter pulses (-128..127)CWTU
153Led 2 right - Command 1 unsigned byte1 Byte5.10 counter pulses (0..255)CWTU
153Led 2 right - Command 2 signed bytes2 Bytes8.1 pulses differenceCWTU
153Led 2 right - Command 2 unsigned bytes2 Bytes7.1 pulsesCWTU
153Led 2 right - Command 2 floating bytes2 Bytes9.1 temperature (°C)CWTU
154Led 3 right - Command 1 bit1 Bit1.1 switchCWTU
154Led 3 right - Command 2 bit2 Bit2.1 switch controlCWTU
154Led 3 right - Command 1 signed byte1 Byte6.10 counter pulses (-128..127)CWTU
154Led 3 right - Command 1 unsigned byte1 Byte5.10 counter pulses (0..255)CWTU
154Led 3 right - Command 2 signed bytes2 Bytes8.1 pulses differenceCWTU
154Led 3 right - Command 2 unsigned bytes2 Bytes7.1 pulsesCWTU
154Led 3 right - Command 2 floating bytes2 Bytes9.1 temperature (°C)CWTU
155Led 4 right - Command 1 bit1 Bit1.1 switchCWTU
155Led 4 right - Command 2 bit2 Bit2.1 switch controlCWTU
155Led 4 right - Command 1 signed byte1 Byte6.10 counter pulses (-128..127)CWTU
155Led 4 right - Command 1 unsigned byte1 Byte5.10 counter pulses (0..255)CWTU
155Led 4 right - Command 2 signed bytes2 Bytes8.1 pulses differenceCWTU
155Led 4 right - Command 2 unsigned bytes2 Bytes7.1 pulsesCWTU
155Led 4 right - Command 2 floating bytes2 Bytes9.1 temperature (°C)CWTU
156Logic function 1 - Input 11 Bit1.1 switchCWTU
157Logic function 1 - Input 21 Bit1.1 switchCWTU
158Logic function 1 - Input 31 Bit1.1 switchCWTU
159Logic function 1 - Input 41 Bit1.1 switchCWTU
160Logic function 1 - Output1 Bit1.1 switchCRT
161Logic function 2 - Input 11 Bit1.1 switchCWTU
162Logic function 2 - Input 21 Bit1.1 switchCWTU
163Logic function 2 - Input 31 Bit1.1 switchCWTU
164Logic function 2 - Input 41 Bit1.1 switchCWTU
165Logic function 2 - Output1 Bit1.1 switchCRT
166Logic function 3 - Input 11 Bit1.1 switchCWTU
167Logic function 3 - Input 21 Bit1.1 switchCWTU
168Logic function 3 - Input 31 Bit1.1 switchCWTU
169Logic function 3 - Input 41 Bit1.1 switchCWTU
170Logic function 3 - Output1 Bit1.1 switchCRT
171Logic function 4 - Input 11 Bit1.1 switchCWTU
172Logic function 4 - Input 21 Bit1.1 switchCWTU
173Logic function 4 - Input 31 Bit1.1 switchCWTU
174Logic function 4 - Input 41 Bit1.1 switchCWTU
175Logic function 4 - Output1 Bit1.1 switchCRT
176Logic function 5 - Input 11 Bit1.1 switchCWTU
177Logic function 5 - Input 21 Bit1.1 switchCWTU
178Logic function 5 - Input 31 Bit1.1 switchCWTU
179Logic function 5 - Input 41 Bit1.1 switchCWTU
180Logic function 5 - Output1 Bit1.1 switchCRT
181Logic function 6 - Input 11 Bit1.1 switchCWTU
182Logic function 6 - Input 21 Bit1.1 switchCWTU
183Logic function 6 - Input 31 Bit1.1 switchCWTU
184Logic function 6 - Input 41 Bit1.1 switchCWTU
185Logic function 6 - Output1 Bit1.1 switchCRT
186Logic function 7 - Input 11 Bit1.1 switchCWTU
187Logic function 7 - Input 21 Bit1.1 switchCWTU
188Logic function 7 - Input 31 Bit1.1 switchCWTU
189Logic function 7 - Input 41 Bit1.1 switchCWTU
190Logic function 7 - Output1 Bit1.1 switchCRT
191Logic function 8 - Input 11 Bit1.1 switchCWTU
192Logic function 8 - Input 21 Bit1.1 switchCWTU
193Logic function 8 - Input 31 Bit1.1 switchCWTU
194Logic function 8 - Input 41 Bit1.1 switchCWTU
195Logic function 8 - Output1 Bit1.1 switchCRT
196Temperature value2 Bytes9.1 temperature (°C)CRT
197Temperature threshold 1 - Switch1 Bit1.1 switchCRT
198Temperature threshold 1 - Lock1 Bit1.3 enableCW
199Temperature threshold 1 - Value (from bus)2 Bytes9.1 temperature (°C)CW
200Temperature threshold 2 - Switch1 Bit1.1 switchCRT
201Temperature threshold 2 - Lock1 Bit1.3 enableCW
202Temperature threshold 2 - Value (from bus)2 Bytes9.1 temperature (°C)CW
203Thermostat - Room temperature (from bus)2 Bytes9.1 temperature (°C)CWTU
204Thermostat - Humidity (2 bytes, from bus)2 Bytes9.7 humidity (%)CWTU
205Thermostat - Humidity (1 byte, from bus)1 Byte5.1 percentage (0..100%)CWTU
206Thermostat - Antistratification temperature (from bus)2 Bytes9.1 temperature (°C)CWTU
207Thermostat - Outdoor temperature (from bus)2 Bytes9.1 temperature (°C)CWTU
208Thermostat - Coil temperature (from bus)2 Bytes9.1 temperature (°C)CWTU
209Thermostat - Floor temperature (from bus)2 Bytes9.1 temperature (°C)CWTU
210Thermostat - Flow temperature (from bus)2 Bytes9.1 temperature (°C)CWTU
211Thermostat - Windows contact sensor 1 (from bus)1 Bit1.19 window/doorCWTU
212Thermostat - Windows contact sensor 2 (from bus)1 Bit1.19 window/doorCWTU
213Thermostat - Presence sensor 1 (from bus)1 Bit1.18 occupancyCWTU
214Thermostat - Presence sensor 2 (from bus)1 Bit1.18 occupancyCWTU
215Thermostat - Card holder contact (from bus)1 Bit1.18 occupancyCWTU
216Thermostat - Anticondensation (from bus)1 Bit1.1 switchCWTU
217Thermostat - Weighted temperature2 Bytes9.1 temperature (°C)CRT
218Thermostat - Heating/cooling status out1 Bit1.100 heating/coolingCRT
219Thermostat - Heating/cooling status in1 Bit1.100 heating/coolingCW
220Thermostat - HVAC mode in1 Byte20.102 HVAC modeCW
221Thermostat - HVAC forced mode in1 Byte20.102 HVAC modeCW
222Thermostat - HVAC mode out1 Byte20.102 HVAC modeCRT
223Thermostat - HVAC manual mode1 Byte20.102 HVAC modeCWTU
224Thermostat - Chrono active status1 Bit1.11 stateCRT
225Thermostat - Actual setpoint2 Bytes9.1 temperature (°C)CRT
226Thermostat - Manual setpoint2 Bytes9.1 temperature (°C)CW
227Thermostat - Comfort setpoint (heating)2 Bytes9.1 temperature (°C)CRWTU
227Thermostat - Input setpoint2 Bytes9.1 temperature (°C)CRWTU
228Thermostat - Comfort setpoint (cooling)2 Bytes9.1 temperature (°C)CRWTU
229Thermostat - Standby setpoint (heating)2 Bytes9.1 temperature (°C)CRWTU
229Thermostat - Standby offset (heating)2 Bytes9.2 temperature difference (K)CRWTU
230Thermostat - Standby setpoint (cooling)2 Bytes9.1 temperature (°C)CRWTU
230Thermostat - Standby offset (cooling)2 Bytes9.2 temperature difference (K)CRWTU
231Thermostat - Economy setpoint (heating)2 Bytes9.1 temperature (°C)CRWTU
231Thermostat - Economy offset (heating)2 Bytes9.2 temperature difference (K)CRWTU
232Thermostat - Economy setpoint (cooling)2 Bytes9.1 temperature (°C)CRWTU
232Thermostat - Economy offset (cooling)2 Bytes9.2 temperature difference (K)CRWTU
233Thermostat - Building protection setpoint (heating)2 Bytes9.1 temperature (°C)CRWTU
234Thermostat - Building protection setpoint (cooling)2 Bytes9.1 temperature (°C)CRWTU
235Thermostat - Room temperature controller status1 Bit1.3 enableCRT
236Thermostat - Heating out command1 Byte5.1 percentage (0..100%)CRT
236Thermostat - Heating out command1 Bit1.1 switchCRT
236Thermostat - Heating and cooling out command1 Bit1.1 switchCRT
236Thermostat - Heating and cooling out command1 Byte5.1 percentage (0..100%)CRT
237Thermostat - Cooling out command1 Byte5.1 percentage (0..100%)CRT
237Thermostat - Cooling out command1 Bit1.1 switchCRT
238Thermostat - Auxiliary heating output command1 Bit1.1 switchCRT
238Thermostat - Auxiliary heating and cooling output command1 Bit1.1 switchCRT
239Thermostat - Auxiliary cooling output command1 Bit1.1 switchCRT
240Thermostat - Auxiliary heating disable1 Bit1.3 enableCW
241Thermostat - Auxiliary cooling disable1 Bit1.3 enableCW
242Thermostat - Fan continuous speed1 Byte5.1 percentage (0..100%)CRT
243Thermostat - Fan speed 11 Bit1.1 switchCRT
244Thermostat - Fan speed 21 Bit1.1 switchCRT
245Thermostat - Fan speed 31 Bit1.1 switchCRT
246Thermostat - Fan control disable1 Bit1.2 booleanCW
247Thermostat - Alarm text14 Bytes16.0 Character String (ASCII)CRT
248Thermostat - Manual setpoint active status1 Bit1.11 stateCRWTU
249Thermostat - Fan manual speed1 Byte5.10 counter pulses (0..255)CRWTU
250Thermostat - Fan speed1 Byte5.10 counter pulses (0..255)CRT
251Thermostat - Fan manual active status1 Bit1.11 stateCRWTU
252Thermostat - Room temperature control alarm1 Bit1.5 alarmCRT
253Thermostat - Disable room temperature controller1 Bit1.1 switchCW
254Thermostat - Dew-point temperature2 Bytes9.1 temperature (°C)CRT
255Thermostat - Relative humidity setpoint for dehumidification2 Bytes9.7 humidity (%)CRWTU
256Thermostat - Relative humidity setpoint for humidification2 Bytes9.7 humidity (%)CRWTU
257Thermostat - Dehumidification command1 Bit1.1 switchCRT
258Thermostat - Dehumidification water battery command1 Bit1.1 switchCRT
259Thermostat - Dehumidification integration control1 Bit1.1 switchCRT
260Thermostat - Dehumidification control disable1 Bit1.2 booleanCW
261Thermostat - Humidification command1 Bit1.1 switchCRT
262Thermostat - Humidification control disable1 Bit1.2 booleanCW
263Thermostat - Anticondensation alarm1 Bit1.5 alarmCRT
264Thermostat - Thermal generator lock1 Bit1.5 alarmCW
265Thermostat - Building protection HVAC mode active1 Bit1.11 stateCRT
266Thermostat - Fan manual speed percentage1 Byte5.1 percentage (0..100%)CRT
267Thermostat - Fan manual speed off status1 Bit1.11 stateCRT
Parameters (265)
ParameterTypeDefault
Signallistnot inverted
Cyclic reading eachlistno reading
Hysteresis positionlistbelow
Hysteresis positionlistabove
Delay for alarm signallist5 min
Thermostat functionlistheating
Heating - cooling cyclic sending intervallistno sending
Heating/cooling changeoverlistfrom bus
Analog sensors timeouttime300
Dehumidification functionlistdisabled
Humidification functionlistdisabled
Flow temperature (project)list14 °C
Digital sensors timeouttime300
Room temperaturelistdisabled
Relative humiditylistdisabled
Antistratification temperaturelistdisabled
Outdoor temperaturelistdisabled
Coil temperaturelistdisabled
Floor surface temperaturelistdisabled
Flow temperaturelistdisabled
Window contact 1listdisabled
Window contact 2listdisabled
Presence sensor 1listdisabled
Presence sensor 2listdisabled
Card holder contactlistdisabled
Humidity CO dimensionlist2 bytes
Cyclic sending intervallistno sending
Minimum change of value to send [K]float 0…50.5
Anticondensationlistdisabled
Relative weightlist50% / 50%
Setpoint cyclic sending intervallistno sending
Comfort temperature setpoint [°C]float 10…5021
Standby temperature offset [0.1 K]signedInt -50…-10-30
Economy temperature offset [0.1 K]signedInt -80…-10-50
Building protection temperature [°C]float 2…107
Control typelist2 points hysteresis
Command Communication Objectlistseparated
Hysteresislist0.3 K
PWM cycle timetime15
Proportional band [0.1K]unsignedInt 5…10040
Integral time [min]unsignedInt 0…25590
Valve protection functionlistdisabled
Frequencylistonce a week
Time intervallist10 s
Floor temperature limitationlistdisabled
Temperature limit [°C]float 20…4029
Auxiliary heatinglistdisabled
Communication objectlistseparated
Offset from setpointlist0.6 K
Disabled from buslistno
Cooling typelistfloor radiant panels
Anticondensation with probelistdisabled
Min control value [%]unsignedInt 0…3015
Min. change of value to send [%]unsignedInt 0…10010
Anticondensation hysteresis rangelist0.5 K
Auxiliary coolinglistdisabled
Control typelist1 speed
Threshold first speed [0.1K]unsignedInt 0…2550
Threshold second speed [0.1K]unsignedInt 0…25510
Threshold third speed [0.1K]unsignedInt 0…25520
Manual operationlistnot depending on the temperature
Hot startlistno
Use coil battery temperature sensor for dehumidificationlistno
Speed control hysteresislist0.3 K
Speed proportional band [0.1K]unsignedInt 5…10030
Min. change of value to send [%]unsignedInt 2…4010
Min. temp. to start ventilation [°C]unsignedInt 28…4028
Min. temp. to start dehumidif. [°C]unsignedInt 0…25510
Relative humidity setpoint [%]unsignedInt 0…10065
Relative humidity setpoint [%]list0.6 %
Max. temp. diff. to disable dehum. [°C]float 0…500.5
Forced speedlist1 speed
Forced speedunsignedInt 0…10020
Antistratification functionlistdisabled
Antistratification temp. differentiallist2.00 [K/m]
Hysteresislist0.5 K
Disable ventilation from buslistno
Signal from buslistnot inverted
Fan start delaylist0 s
Fan stop delaylist0 s
Dew-point temperaturelistdisabled
Min. change of value to send [K]list0.2 K
Windows contacts functionlistdisabled
Presence sensors functionlistdisabled
Presence sensors uselistcomfort extension
Thermostat modeslistcomfort - standby
Wait time to building protection modetime60
Absence time to switch HVAC modetime60
Card holder functionlistdisabled
On card insertion switch HVAC mode tolistcomfort
On card removal switch HVAC mode toliststandby
Activation delay on card insertiontime0
Activation delay on card removaltime0
Ventilation for auxiliary coolinglistdisabled
End of manual operationlistat first telegram from bus
Heating typelistradiators
Heating typelistfancoils
Humidity hysteresislist0.8 %
Subordinated to temperature controllistyes
Humidity setpointunsignedInt 20…8055
Integrationlistno
Dehumidification start delaytime300
Temperature difference for integrationlist1.5 °C
Hysteresis for integrationlist0.5 K
Disable dehumid. control from buslistno
Humidity setpointunsignedInt 20…8035
Disable humidification control from buslistno
Max control value [%]unsignedInt 70…10085
Active anticondensationlistdisabled
Transmission delay after mode changetime400
Channel 1listindependent or single
Channel 2listindependent or single
Delay after bus voltage recoverytime400
Button 1 leftlistenabled
Long press timetime80
Lock functionlistdisabled
Invert lock device signallistnot inverted
Lock after bus recoverylistno
Typelistsend values or sequences
Number of Communication ObjectsunsignedInt 1…81
Eventlistactivation / release
Behavior at lockinglistnone
Behavior at unlockinglistnone
Send cyclicallylistnone
Cyclic sending intervaltime120
Send delaytime0
Communication object dimensionlist1 bit value
Reaction to activationlisttoggle
Reaction to releaselistoff
Reaction to short presslisttoggle
Reaction to long presslistoff
Reaction to activationlistenable on / down
Reaction to releaselistdisable
Reaction to short presslistenable on / down
Reaction to long presslistdisable
Reaction to activationlistsend value 1
Reaction to releaselistnone
Reaction to short presslistsend value 1
Reaction to long presslistnone
Value 1unsignedInt 0…2550
Value 2unsignedInt 0…2550
Value 1signedInt -128…1270
Value 2signedInt -128…1270
Value 1unsignedInt 0…655350
Value 2unsignedInt 0…655350
Value 1signedInt -32768…327670
Value 2signedInt -32768…327670
Value 1float -671088.64…670760.960
Value 2float -671088.64…670760.960
Reaction to activationliston
Reaction to short pressliston
Toggle modelistenabled
Short / long actionlistoff / darker
Up / down actionlistup
Venetian blind modelistdisabled
Learning modelistdisabled
Scene activationlistsend first scene only
First scene numberunsignedInt 1…641
Second scene numberunsignedInt 1…642
Button 2 leftlistenabled
Typelistdimming
1 and 2 uselistA increases, B decreases
1 and 2 uselistA up, B down
1 and 2 uselistA on, B off
Button 3 leftlistenabled
Button 4 leftlistenabled
3 and 4 uselistA on, B off
3 and 4 uselistA increases, B decreases
3 and 4 uselistA up, B down
Reaction to long presslistdarker
Value 1unsignedInt 0…1000
Value 2unsignedInt 0…1000
Logic functionlistdisabled
Logic operationlistOR
Output cyclic transmission intervallistno sending
Logic object 1listdisabled
Logic object 2listdisabled
Logic object 3listdisabled
Logic object 4listdisabled
Logic object 1 negatedlistno
Logic object 2 negatedlistno
Logic object 3 negatedlistno
Logic object 4 negatedlistno
Logic object 1 read at startuplistno
Logic object 2 read at startuplistno
Logic object 3 read at startuplistno
Logic object 4 read at startuplistno
Logic object 1 default valuelistnone
Logic object 2 default valuelistnone
Logic object 3 default valuelistnone
Logic object 4 default valuelistnone
Output sendlistboth values
Output updatingliston value change
Technical alarmlistdisabled
Contact typelistNO (normally open)
Setpoint typelistsingle
Ventilation for auxiliary heatinglistdisabled
Threshold 1listnot active
Threshold 2listnot active
Value [°C]float 0…507
Value [°C]float 0…5045
Hysteresislist0.4 K
Temperature offsetlist0.0 °C
Thermostat functionalitieslistdisabled
Filter typelistmedium
Temperature setpoint [°C]float 10…5021
Temperature setpoint [°C]float 10…5023
Standby temperature offset [0.1 K]signedInt 10…5030
Economy temperature offset [0.1 K]signedInt 10…8050
Building protection temperature [°C]float 10…5036
Disable temperature controller from buslistno
HVAC mode after downloadlistno change
Neutral zone [0.1 K]signedInt 10…8020
Channel 3listindependent or single
Channel 4listindependent or single
Proximity sensorlistdisabled
Temperature sensorlistdisabled
Threshold value update from buslistno
Threshold lock enablelistno
Behaviour at locklistnone
Behaviour at bus recoverylistprevious state
Led 1 left activationliston contact closed
Color Offtext#00D4FF
Color Ontext#00FF00
Off delaytime10
Blinking periodlistnone
Threshold typelist1 bit
Number of thresholdsunsignedInt 1…81
ValueunsignedInt 0…655350
Leds intensityunsignedInt 0…10050
Sensitivitylistmedium
Maximum standby intensityunsignedInt 0…10080
Send values or sequenceslistdisabled
Reaction to presence detectedlisttoggle
Reaction to presence not detectedlistoff
Reaction to presence detectedlistenable on / down
Reaction to presence not detectedlistdisable
Reaction to presence detectedlistsend value 1
Reaction to presence not detectedlistnone
Reaction to presence detectedliston
Colortext#00D4FF
Colortext#FFFF00
ValuesignedInt -32768…327670
ValueunsignedInt 0…2550
ValuesignedInt -128…1270
Valuefloat -671088.64…670760.960
Product codelistEK-E20-TP-4LS
Button 1 rightlistenabled
Button 2 rightlistenabled
Button 3 rightlistenabled
Button 4 rightlistenabled
Leds intensity from buslistno
Backlight durationtime0
Led 2 left activationliston contact closed
Led 3 left activationliston contact closed
Led 4 left activationliston contact closed
Led 1 right activationliston contact closed
Led 2 right activationliston contact closed
Led 3 right activationliston contact closed
Led 4 right activationliston contact closed
Standby temperature setpoint [°C]float 10…5018
Economy temperature setpoint [°C]float 10…5016
Standby temperature setpoint [°C]float 10…5026
Economy temperature setpoint [°C]float 10…5028
AlwaysYeslistyes

Version history

ApplicationApp noFingerprintFirst seenSizeFile
APEKE20TP 0.3 latest$453244742026-11-25448 KBDownload
APEKE20TP 0.2$4532D2572026-11-25448 KBDownload

About this file

This is the official ETS product database for the Ekinex S.p.A. Pushbutton 20venti 4-fold left with backlit text/symbols and proximity sensor (EK-E20-TP-4TS-P), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.

More from Ekinex S.p.A.

All Ekinex S.p.A. products