KNX Database
Ekinex S.p.A. EK-DF2-TP EK-DF2-TP

EK-DF2-TP

Ekinex S.p.A. · Order number EK-DF2-TP · Presence sensors › Indoor

Download .knxprod KXA04 0.1 · 121 KB

Product

ManufacturerEkinex S.p.A.
Product nameEK-DF2-TP
Order numberEK-DF2-TP
HardwareEK-DG2-TP
MediumTwisted Pair
Bus current (mA)10
Rail mountedNo
RegistrationCertified · 2020-02-11
Languagesen-US, de-DE, fr-FR, it-IT
Catalog entryM-00B6_H-SN005-1-O0153_HP-0001-01-CE00-O0153_CI-EK.2DDF2.2DTP-1
FingerprintCE00
SHA-2569d7b657ec938ceb9f92abfb229c07b75dff924931f34af900491f711a6f5ec32
First seen2026-11-25
Markets69 markets

Application program: KXA04 0.1

Application number$0001
Version0.1
Mask versionMV-07B0 (System B)
KNX Data SecureNo
Minimum ETS version5.0
Parameters59
Group objects18
Group objects (18)
NoNameFunctionSizeDPTFlags
1Slave inputSlave motion1 Bit1.17 triggerCW
2Slave outputSlave motion1 Bit1.1 switchCRT
3Test outputON/OFF1 Bit1.1 switchCRT
4Measured lux value outputCurrent light value2 Bytes9.4 lux (Lux)CRT
5C1 manual inputON/OFF/Dim1 Bit1.1 switchCW
6C2 manual inputON/OFF/Dim1 Bit1.1 switchCW
7C3 manual inputON/OFF1 Bit1.1 switchCW
8C4 manual inputON/OFF1 Bit1.1 switchCW
9C1 Light control outputON/OFF1 Bit1.1 switchCRT
10C1 Light control dimming valueDim value1 Byte5.1 percentage (0..100%)CRT
11C1 Constant light controloutput4 BitDPT.3CRT
12C2 Light control outputON/OFF1 Bit1.1 switchCRT
13C2 Light control dimming valueDim value1 Byte5.1 percentage (0..100%)CRT
14C2 Constant light controloutput4 BitDPT.3CRT
15C3 HVAC control outputON/OFF1 Bit1.1 switchCRT
16C4 HVAC control outputON/OFF1 Bit1.1 switchCRT
17Lock alarm1 locks; 0unlocks"1 Bit1.3 enableCW
18Alarm outputON/OFF1 Bit1.5 alarmCRT
Parameters (41)
ParameterTypeDefault
HVAC switch-'ON' delaylist1min.
> HVAC control output C4listDisable
> Switch ON Lux valuelist2000Lux
- Time after switch-on until constant light control startslist1min.
LED ON when PIR triggedlistEnable
Lux/Time/Meter/STBY selected bylistETS
Behaviour at switching off lock by communication objectlistSwitch off
Duration of one switch-off windowlist0.5sec.
Behaviour at switching on lock by communication objectlistNo reaction
Output typelistSwitching
Number of switch-off windowsunsignedInt 0…10010
> HVAC control output C3listEnable
delayTime1unsignedInt 0…65535100
Behaviour at switching on lock by communication objectlistSwitch on
Behaviour at switching off lock by communication objectlistNo reaction
Auto/Semi auto selectlistAuto
> Alarm functionlistDisable
Number of switch-on windowsunsignedInt 0…10010
> Light control output C2listDisable
> Lighting delay timelist5min.
The device type islistMaster
- Lux deviationunsignedInt 0…25510
HVAC delay timelist5min.
> Lighting standby timelistDisable
- Standby brightnesslist10%
- Preset setpointlist300Lux
> Constant light controllistDisable
> Input SlavelistLight output C1
> Dimming value during ON phaselist100%
External switch as ON/OFF/Dim inputlistNO
> Light control output C1listEnable
Duration of one switch-on windowlist0.5sec.
- Standby timelist5min.
> Test mode (activated for 10min. After download by choosing Enable)"listDisable
> Sensor sensitivitylistMaximum
> Sensor sensitivity (Lower area)listMaximum
Sensor warm-up time after voltage recoverytextNeed about 60sec to stabilize the sensor
When Lux/Time/Meter/STBY selected bytextETS
When the device type is selected bytextSlave
ETS_SetupFlagunsignedInt 0…255255
> Measured lux value reportlistDisable

Version history

ApplicationApp noFingerprintFirst seenSizeFile
KXA04 0.1 latest$0001CE002026-11-25121 KBDownload

About this file

This is the official ETS product database for the Ekinex S.p.A. EK-DF2-TP (EK-DF2-TP), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.

More from Ekinex S.p.A.

All Ekinex S.p.A. products