KNX Database
Ekinex S.p.A. EK-CF2-TP Interface for load monitoring and control

Interface for load monitoring and control EK-CF2-TP

Ekinex S.p.A. · Order number EK-CF2-TP · Metering

Interface for load monitoring and control

Download .knxprod APEKCF2TP 0.2 · 136 KB

Product

ManufacturerEkinex S.p.A.
Product nameInterface for load monitoring and control
Order numberEK-CF2-TP
HardwareInterfaccia gestione consumi e carichi
MediumTwisted Pair
Bus current (mA)10
Rail mountedNo
RegistrationCertified · 2017-09-19
Languagesen-US, de-DE, fr-FR, it-IT
Catalog entryM-00B6_H-00B600000028-1_HP-4346-02-CA27_CI-EK.2DCF2.2DTP-1
FingerprintCA27
SHA-256143f93f183bed64f03656e368e97fbe3e47fc11989c30a611e4f9a0146cca812
First seen2026-11-25
Markets69 markets

Application program: APEKCF2TP 0.2

Application number$4346
Version0.2
Mask versionMV-0705 (7.5)
KNX Data SecureNo
Minimum ETS version4.0
Parameters562
Group objects232
Group objects (232)
NoNameFunctionSizeDPTFlags
0Channel 1 - Instantaneous current (mA)2 Bytes9.21 current (mA)CRT
1Channel 1 - Instantaneous power (W)4 Bytes14.56 power (W)CRT
1Channel 1 - Instantaneous power (W) from bus4 Bytes14.56 power (W)CWTU
2Channel 1 - Instantaneous power (kW)2 Bytes9.24 power (kW)CRT
2Channel 1 - Instantaneous power (kW) from bus2 Bytes9.24 power (kW)CWTU
3Channel 1 - Total energy consumed (kWh)4 Bytes13.13 active energy (kWh)CRT
4Channel 1 - Total energy consumed counter reset1 Bit1.15 resetCW
5Channel 1 - Threshold 14 Bytes14.56 power (W)CW
6Channel 1 - Threshold 24 Bytes14.56 power (W)CW
7Channel 1 - Threshold 34 Bytes14.56 power (W)CW
8Channel 1 - Threshold 44 Bytes14.56 power (W)CW
9Channel 1 - Threshold 54 Bytes14.56 power (W)CW
10Channel 1 - Threshold 64 Bytes14.56 power (W)CW
11Channel 1 - Threshold 74 Bytes14.56 power (W)CW
12Channel 1 - Threshold 84 Bytes14.56 power (W)CW
13Channel 1 - Threshold 1 block1 Bit1.3 enableCWU
14Channel 1 - Threshold 2 block1 Bit1.3 enableCWU
15Channel 1 - Threshold 3 block1 Bit1.3 enableCWU
16Channel 1 - Threshold 4 block1 Bit1.3 enableCWU
17Channel 1 - Threshold 5 block1 Bit1.3 enableCWU
18Channel 1 - Threshold 6 block1 Bit1.3 enableCWU
19Channel 1 - Threshold 7 block1 Bit1.3 enableCWU
20Channel 1 - Threshold 8 block1 Bit1.3 enableCWU
21Channel 1 - Threshold 1 status1 Bit1.1 switchCRT
22Channel 1 - Threshold 2 status1 Bit1.1 switchCRT
23Channel 1 - Threshold 3 status1 Bit1.1 switchCRT
24Channel 1 - Threshold 4 status1 Bit1.1 switchCRT
25Channel 1 - Threshold 5 status1 Bit1.1 switchCRT
26Channel 1 - Threshold 6 status1 Bit1.1 switchCRT
27Channel 1 - Threshold 7 status1 Bit1.1 switchCRT
28Channel 1 - Threshold 8 status1 Bit1.1 switchCRT
29Channel 1 - Load control power threshold writing4 Bytes14.56 power (W)CW
30Channel 1 - Load control power threshold reading4 Bytes14.56 power (W)CRT
31Channel 1 - Load 1 control status1 Bit1.1 switchCRT
32Channel 1 - Load 2 control status1 Bit1.1 switchCRT
33Channel 1 - Load 3 control status1 Bit1.1 switchCRT
34Channel 1 - Load 4 control status1 Bit1.1 switchCRT
35Channel 1 - Load 5 control status1 Bit1.1 switchCRT
36Channel 1 - Load 6 control status1 Bit1.1 switchCRT
37Channel 1 - Load 7 control status1 Bit1.1 switchCRT
38Channel 1 - Load 8 control status1 Bit1.1 switchCRT
39Channel 1 - Load 1 control exclusion1 Bit1.3 enableCWU
40Channel 1 - Load 2 control exclusion1 Bit1.3 enableCWU
41Channel 1 - Load 3 control exclusion1 Bit1.3 enableCWU
42Channel 1 - Load 4 control exclusion1 Bit1.3 enableCWU
43Channel 1 - Load 5 control exclusion1 Bit1.3 enableCWU
44Channel 1 - Load 6 control exclusion1 Bit1.3 enableCWU
45Channel 1 - Load 7 control exclusion1 Bit1.3 enableCWU
46Channel 1 - Load 8 control exclusion1 Bit1.3 enableCWU
47Channel 1 - Load control reset1 Bit1.15 resetCW
48Channel 1 - Load control status1 Bit1.1 switchCRT
49Channel 1 - Load control threshold status1 Bit1.1 switchCRT
50Channel 1 - Load control threshold status reset1 Bit1.15 resetCW
51Channel 2 - Instantaneous current (mA)2 Bytes9.21 current (mA)CRT
52Channel 2 - Instantaneous power (W)4 Bytes14.56 power (W)CRT
52Channel 2 - Instantaneous power (W) from bus4 Bytes14.56 power (W)CWTU
53Channel 2 - Instantaneous power (kW)2 Bytes9.24 power (kW)CRT
53Channel 2 - Instantaneous power (kW) from bus2 Bytes9.24 power (kW)CWTU
54Channel 2 - Total energy consumed (kWh)4 Bytes13.13 active energy (kWh)CRT
55Channel 2 - Total energy consumed counter reset1 Bit1.15 resetCW
56Channel 2 - Threshold 14 Bytes14.56 power (W)CW
57Channel 2 - Threshold 24 Bytes14.56 power (W)CW
58Channel 2 - Threshold 34 Bytes14.56 power (W)CW
59Channel 2 - Threshold 44 Bytes14.56 power (W)CW
60Channel 2 - Threshold 54 Bytes14.56 power (W)CW
61Channel 2 - Threshold 64 Bytes14.56 power (W)CW
62Channel 2 - Threshold 74 Bytes14.56 power (W)CW
63Channel 2 - Threshold 84 Bytes14.56 power (W)CW
64Channel 2 - Threshold 1 block1 Bit1.3 enableCWU
65Channel 2 - Threshold 2 block1 Bit1.3 enableCWU
66Channel 2 - Threshold 3 block1 Bit1.3 enableCWU
67Channel 2 - Threshold 4 block1 Bit1.3 enableCWU
68Channel 2 - Threshold 5 block1 Bit1.3 enableCWU
69Channel 2 - Threshold 6 block1 Bit1.3 enableCWU
70Channel 2 - Threshold 7 block1 Bit1.3 enableCWU
71Channel 2 - Threshold 8 block1 Bit1.3 enableCWU
72Channel 2 - Threshold 1 status1 Bit1.1 switchCRT
73Channel 2 - Threshold 2 status1 Bit1.1 switchCRT
74Channel 2 - Threshold 3 status1 Bit1.1 switchCRT
75Channel 2 - Threshold 4 status1 Bit1.1 switchCRT
76Channel 2 - Threshold 5 status1 Bit1.1 switchCRT
77Channel 2 - Threshold 6 status1 Bit1.1 switchCRT
78Channel 2 - Threshold 7 status1 Bit1.1 switchCRT
79Channel 2 - Threshold 8 status1 Bit1.1 switchCRT
80Channel 2 - Load control power threshold writing4 Bytes14.56 power (W)CW
81Channel 2 - Load control power threshold reading4 Bytes14.56 power (W)CRT
82Channel 2 - Load 1 control status1 Bit1.1 switchCRT
83Channel 2 - Load 2 control status1 Bit1.1 switchCRT
84Channel 2 - Load 3 control status1 Bit1.1 switchCRT
85Channel 2 - Load 4 control status1 Bit1.1 switchCRT
86Channel 2 - Load 5 control status1 Bit1.1 switchCRT
87Channel 2 - Load 6 control status1 Bit1.1 switchCRT
88Channel 2 - Load 7 control status1 Bit1.1 switchCRT
89Channel 2 - Load 8 control status1 Bit1.1 switchCRT
90Channel 2 - Load 1 control exclusion1 Bit1.3 enableCWU
91Channel 2 - Load 2 control exclusion1 Bit1.3 enableCWU
92Channel 2 - Load 3 control exclusion1 Bit1.3 enableCWU
93Channel 2 - Load 4 control exclusion1 Bit1.3 enableCWU
94Channel 2 - Load 5 control exclusion1 Bit1.3 enableCWU
95Channel 2 - Load 6 control exclusion1 Bit1.3 enableCWU
96Channel 2 - Load 7 control exclusion1 Bit1.3 enableCWU
97Channel 2 - Load 8 control exclusion1 Bit1.3 enableCWU
98Channel 2 - Load control reset1 Bit1.15 resetCW
99Channel 2 - Load control status1 Bit1.1 switchCRT
100Channel 2 - Load control threshold status1 Bit1.1 switchCRT
101Channel 2 - Load control threshold status reset1 Bit1.15 resetCW
102Channel 3 - Instantaneous current (mA)2 Bytes9.21 current (mA)CRT
103Channel 3 - Instantaneous power (W)4 Bytes14.56 power (W)CRT
103Channel 3 - Instantaneous power (W) from bus4 Bytes14.56 power (W)CWTU
104Channel 3 - Instantaneous power (kW)2 Bytes9.24 power (kW)CRT
104Channel 3 - Instantaneous power (kW) from bus2 Bytes9.24 power (kW)CWTU
105Channel 3 - Total energy consumed (kWh)4 Bytes13.13 active energy (kWh)CRT
106Channel 3 - Total energy consumed counter reset1 Bit1.15 resetCW
107Channel 3 - Threshold 14 Bytes14.56 power (W)CW
108Channel 3 - Threshold 24 Bytes14.56 power (W)CW
109Channel 3 - Threshold 34 Bytes14.56 power (W)CW
110Channel 3 - Threshold 44 Bytes14.56 power (W)CW
111Channel 3 - Threshold 54 Bytes14.56 power (W)CW
112Channel 3 - Threshold 64 Bytes14.56 power (W)CW
113Channel 3 - Threshold 74 Bytes14.56 power (W)CW
114Channel 3 - Threshold 84 Bytes14.56 power (W)CW
115Channel 3 - Threshold 1 block1 Bit1.3 enableCWU
116Channel 3 - Threshold 2 block1 Bit1.3 enableCWU
117Channel 3 - Threshold 3 block1 Bit1.3 enableCWU
118Channel 3 - Threshold 4 block1 Bit1.3 enableCWU
119Channel 3 - Threshold 5 block1 Bit1.3 enableCWU
120Channel 3 - Threshold 6 block1 Bit1.3 enableCWU
121Channel 3 - Threshold 7 block1 Bit1.3 enableCWU
122Channel 3 - Threshold 8 block1 Bit1.3 enableCWU
123Channel 3 - Threshold 1 status1 Bit1.1 switchCRT
124Channel 3 - Threshold 2 status1 Bit1.1 switchCRT
125Channel 3 - Threshold 3 status1 Bit1.1 switchCRT
126Channel 3 - Threshold 4 status1 Bit1.1 switchCRT
127Channel 3 - Threshold 5 status1 Bit1.1 switchCRT
128Channel 3 - Threshold 6 status1 Bit1.1 switchCRT
129Channel 3 - Threshold 7 status1 Bit1.1 switchCRT
130Channel 3 - Threshold 8 status1 Bit1.1 switchCRT
131Channel 3 - Load control power threshold writing4 Bytes14.56 power (W)CW
132Channel 3 - Load control power threshold reading4 Bytes14.56 power (W)CRT
133Channel 3 - Load 1 control status1 Bit1.1 switchCRT
134Channel 3 - Load 2 control status1 Bit1.1 switchCRT
135Channel 3 - Load 3 control status1 Bit1.1 switchCRT
136Channel 3 - Load 4 control status1 Bit1.1 switchCRT
137Channel 3 - Load 5 control status1 Bit1.1 switchCRT
138Channel 3 - Load 6 control status1 Bit1.1 switchCRT
139Channel 3 - Load 7 control status1 Bit1.1 switchCRT
140Channel 3 - Load 8 control status1 Bit1.1 switchCRT
141Channel 3 - Load 1 control exclusion1 Bit1.3 enableCWU
142Channel 3 - Load 2 control exclusion1 Bit1.3 enableCWU
143Channel 3 - Load 3 control exclusion1 Bit1.3 enableCWU
144Channel 3 - Load 4 control exclusion1 Bit1.3 enableCWU
145Channel 3 - Load 5 control exclusion1 Bit1.3 enableCWU
146Channel 3 - Load 6 control exclusion1 Bit1.3 enableCWU
147Channel 3 - Load 7 control exclusion1 Bit1.3 enableCWU
148Channel 3 - Load 8 control exclusion1 Bit1.3 enableCWU
149Channel 3 - Load control reset1 Bit1.15 resetCW
150Channel 3 - Load control status1 Bit1.1 switchCRT
151Channel 3 - Load control threshold status1 Bit1.1 switchCRT
152Channel 3 - Load control threshold status reset1 Bit1.15 resetCW
153Channel 4 - Instantaneous current (mA)2 Bytes9.21 current (mA)CRT
154Channel 4 - Instantaneous power (W)4 Bytes14.56 power (W)CRT
154Channel 4 - Instantaneous power (W) from bus4 Bytes14.56 power (W)CWTU
155Channel 4 - Instantaneous power (kW)2 Bytes9.24 power (kW)CRT
155Channel 4 - Instantaneous power (kW) from bus2 Bytes9.24 power (kW)CWTU
156Channel 4 - Total energy consumed (kWh)4 Bytes13.13 active energy (kWh)CRT
157Channel 4 - Total energy consumed counter reset1 Bit1.15 resetCW
158Channel 4 - Threshold 14 Bytes14.56 power (W)CW
159Channel 4 - Threshold 24 Bytes14.56 power (W)CW
160Channel 4 - Threshold 34 Bytes14.56 power (W)CW
161Channel 4 - Threshold 44 Bytes14.56 power (W)CW
162Channel 4 - Threshold 54 Bytes14.56 power (W)CW
163Channel 4 - Threshold 64 Bytes14.56 power (W)CW
164Channel 4 - Threshold 74 Bytes14.56 power (W)CW
165Channel 4 - Threshold 84 Bytes14.56 power (W)CW
166Channel 4 - Threshold 1 block1 Bit1.3 enableCWU
167Channel 4 - Threshold 2 block1 Bit1.3 enableCWU
168Channel 4 - Threshold 3 block1 Bit1.3 enableCWU
169Channel 4 - Threshold 4 block1 Bit1.3 enableCWU
170Channel 4 - Threshold 5 block1 Bit1.3 enableCWU
171Channel 4 - Threshold 6 block1 Bit1.3 enableCWU
172Channel 4 - Threshold 7 block1 Bit1.3 enableCWU
173Channel 4 - Threshold 8 block1 Bit1.3 enableCWU
174Channel 4 - Threshold 1 status1 Bit1.1 switchCRT
175Channel 4 - Threshold 2 status1 Bit1.1 switchCRT
176Channel 4 - Threshold 3 status1 Bit1.1 switchCRT
177Channel 4 - Threshold 4 status1 Bit1.1 switchCRT
178Channel 4 - Threshold 5 status1 Bit1.1 switchCRT
179Channel 4 - Threshold 6 status1 Bit1.1 switchCRT
180Channel 4 - Threshold 7 status1 Bit1.1 switchCRT
181Channel 4 - Threshold 8 status1 Bit1.1 switchCRT
182Channel 4 - Load control power threshold writing4 Bytes14.56 power (W)CW
183Channel 4 - Load control power threshold reading4 Bytes14.56 power (W)CRT
184Channel 4 - Load 1 control status1 Bit1.1 switchCRT
185Channel 4 - Load 2 control status1 Bit1.1 switchCRT
186Channel 4 - Load 3 control status1 Bit1.1 switchCRT
187Channel 4 - Load 4 control status1 Bit1.1 switchCRT
188Channel 4 - Load 5 control status1 Bit1.1 switchCRT
189Channel 4 - Load 6 control status1 Bit1.1 switchCRT
190Channel 4 - Load 7 control status1 Bit1.1 switchCRT
191Channel 4 - Load 8 control status1 Bit1.1 switchCRT
192Channel 4 - Load 1 control exclusion1 Bit1.3 enableCWU
193Channel 4 - Load 2 control exclusion1 Bit1.3 enableCWU
194Channel 4 - Load 3 control exclusion1 Bit1.3 enableCWU
195Channel 4 - Load 4 control exclusion1 Bit1.3 enableCWU
196Channel 4 - Load 5 control exclusion1 Bit1.3 enableCWU
197Channel 4 - Load 6 control exclusion1 Bit1.3 enableCWU
198Channel 4 - Load 7 control exclusion1 Bit1.3 enableCWU
199Channel 4 - Load 8 control exclusion1 Bit1.3 enableCWU
200Channel 4 - Load control reset1 Bit1.15 resetCW
201Channel 4 - Load control status1 Bit1.1 switchCRT
202Channel 4 - Load control threshold status1 Bit1.1 switchCRT
203Channel 4 - Load control threshold status reset1 Bit1.15 resetCW
204Logic function 1 - Input 11 Bit1.1 switchCWTU
205Logic function 1 - Input 21 Bit1.1 switchCWTU
206Logic function 1 - Input 31 Bit1.1 switchCWTU
207Logic function 1 - Input 41 Bit1.1 switchCWTU
208Logic function 1 - Output1 Bit1.1 switchCRT
209Logic function 2 - Input 11 Bit1.1 switchCWTU
210Logic function 2 - Input 21 Bit1.1 switchCWTU
211Logic function 2 - Input 31 Bit1.1 switchCWTU
212Logic function 2 - Input 41 Bit1.1 switchCWTU
213Logic function 2 - Output1 Bit1.1 switchCRT
214Logic function 3 - Input 11 Bit1.1 switchCWTU
215Logic function 3 - Input 21 Bit1.1 switchCWTU
216Logic function 3 - Input 31 Bit1.1 switchCWTU
217Logic function 3 - Input 41 Bit1.1 switchCWTU
218Logic function 3 - Output1 Bit1.1 switchCRT
219Logic function 4 - Input 11 Bit1.1 switchCWTU
220Logic function 4 - Input 21 Bit1.1 switchCWTU
221Logic function 4 - Input 31 Bit1.1 switchCWTU
222Logic function 4 - Input 41 Bit1.1 switchCWTU
223Logic function 4 - Output1 Bit1.1 switchCRT
Parameters (92)
ParameterTypeDefault
Logic functionlistdisabled
Logic operationlistOR
Output cyclic transmission intervallistno sending
Delay after bus voltage recoverytime400
Logic object 1listdisabled
Logic object 2listdisabled
Logic object 3listdisabled
Logic object 4listdisabled
Logic object 1 negatedlistno
Logic object 2 negatedlistno
Logic object 3 negatedlistno
Logic object 4 negatedlistno
Logic object 1 read at startuplistno
Logic object 2 read at startuplistno
Logic object 3 read at startuplistno
Logic object 4 read at startuplistno
Logic object 1 default valuelistnone
Logic object 2 default valuelistnone
Logic object 3 default valuelistnone
Logic object 4 default valuelistnone
Delay after bus voltage recoverytime3
Measuring channel 1listdisable
Power supply voltageunsignedInt 220…440230
Power factor (cosφ)list0.90
CT type at input 1list20 A
Current point 1 measured by inputfloat 0…600
Current point 1 measured by userfloat 0…600
Power and current values on change sendingunsignedInt 0…10000
Power and current values cyclical sendinglistno sending
Enable thresholdslistdisabled
Power value cyclical readinglistno reading
Power value at startup readinglistno
Power value reading timeouttime0
Energy counter cyclic sendinglistno sending
Energy counter sending on changesignedInt 0…500
Enable load controllistdisabled
Threshold 1listdisabled
ValueunsignedInt 10…32000500
Statuslistnot inverted
HysteresisunsignedInt 0…1000500
Typelistabove
disable from buslistno
Disable modelistnot inverted
Status cyclical sendinglistno sending
Threshold 2listdisabled
Threshold 3listdisabled
Threshold 4listdisabled
Threshold 5listdisabled
Threshold 6listdisabled
Threshold 7listdisabled
Threshold 8listdisabled
Load control number enabledunsignedInt 1…81
Load control resetlistdisabled
Load control reset modelistnot inverted
Load status cyclical sendinglistno sending
Threshold for load controlunsignedInt 100…320002900
Load deactivation timeunsignedInt 10…30010
Load reactivation timeunsignedInt 10…30010
Load 1 control exclusionlistdisabled
Load 2 control exclusionlistdisabled
Load 3 control exclusionlistdisabled
Load 4 control exclusionlistdisabled
Load 5 control exclusionlistdisabled
Load 6 control exclusionlistdisabled
Load 7 control exclusionlistdisabled
Load 8 control exclusionlistdisabled
Load 1 control exclusion modelistnot inverted
Load 2 control exclusion modelistnot inverted
Load 3 control exclusion modelistnot inverted
Load 4 control exclusion modelistnot inverted
Load 5 control exclusion modelistnot inverted
Load 6 control exclusion modelistnot inverted
Load 7 control exclusion modelistnot inverted
Load 8 control exclusion modelistnot inverted
Load exclusion reset timelist1 min
Load control threshold status reset timelistnone
Output sendinglistboth values
Output updatelistat value change
Measuring channel 2listdisable
Measuring channel 3listdisable
Measuring channel 4listdisable
Power supply voltageunsignedInt 220…440400
CT type at input 2list20 A
CT type at input 3list20 A
Threshold activation delayunsignedInt 0…2550
Load control hysteresisunsignedInt 50…100050
Current point 2 measured by inputfloat 0…600
Current point 2 measured by userfloat 0…600
Enable measure correctionlistdisabled
Counter reset after downloading the application swlistyes
Threshold reset after downloading the application swlistyes
Load control reset after downloading the application swlistyes

Version history

ApplicationApp noFingerprintFirst seenSizeFile
APEKCF2TP 0.2 latest$4346CA272026-11-25136 KBDownload

About this file

This is the official ETS product database for the Ekinex S.p.A. Interface for load monitoring and control (EK-CF2-TP), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.