3025 4 CH - SB40A SB40A10KNX

Eelectron · Order number SB40A10KNX · Push Buttons 3025 › 4 Channels

SB40A 4 CH

Download .knxprod SB40AxxKNX 1.2 · 548 KB

Product

ManufacturerEelectron
Product name3025 4 CH - SB40A
Order numberSB40A10KNX
HardwareSB40AxxKNX
MediumTwisted Pair
Bus current (mA)5
Rail mountedNo
RegistrationCertified · 2018-09-14
Languagesfr-FR, it-IT, en-US, de-DE, es-ES, ru-RU
Catalog entryM-006C_H-SB40AxxKNX-16_HP-0080-12-386E_CI-SB40A10KNX-1
Fingerprint386E
SHA-2565e117275c15ba1784fbfbb3493ea04767d0390d40ad2b0e8e8681813d7b12d36
First seen2026-11-25
Markets59 markets

Application program: SB40AxxKNX 1.2

Application number$0080
Version1.2
Mask versionMV-0021 (2.1)
KNX Data SecureNo
Minimum ETS version4.0
Parameters927
Group objects595
Group objects (595)
NoNameFunctionSizeDPTFlags
0<Button UP> Sequence Command A0-100%1 Byte5.1 percentage (0..100%)CRT
0<Button UP> Sequence Command AHVAC Mode1 Byte20.102 HVAC modeCRT
0<Button UP> Sequence Command A0-2551 Byte5.10 counter pulses (0..255)CRT
0<Button UP> Sequence Command AOff/On1 Bit1.1 switchCRT
0<Button UP> Press ActionOff/On1 Bit1.1 switchCRWT
0<Button UP> Press Action0-100%1 Byte5.1 percentage (0..100%)CRT
0<Button UP> Press Action0-2551 Byte5.10 counter pulses (0..255)CRT
0<Button UP> Press ActionHVAC Mode1 Byte20.102 HVAC modeCRT
0<Button UP> Press - Release ActionOff/On1 Bit1.1 switchCRWT
0<Button UP> Press - Release Action0-100%1 Byte5.1 percentage (0..100%)CRT
0<Button UP> Press - Release Action0-2551 Byte5.10 counter pulses (0..255)CRT
0<Button UP> Press - Release ActionHVAC Mode1 Byte20.102 HVAC modeCRT
0<Button UP> ShutterUp/Down1 Bit1.8 up/downCRWT
0<Button UP> Short - Long PressOff/On1 Bit1.1 switchCRWT
0<Button UP> Short - Long Press0-100%1 Byte5.1 percentage (0..100%)CRT
0<Button UP> Short - Long Press0-2551 Byte5.10 counter pulses (0..255)CRT
0<Button UP> Short - Long PressHVAC Mode1 Byte20.102 HVAC modeCRT
0<Button UP> Dimmer On/OffOff/On1 Bit1.1 switchCRWT
0<Button UP> Recall/Learn SceneScene1 Byte18.1 scene controlCRT
0<Button UP> Red0-2551 Byte5.10 counter pulses (0..255)CRT
1<Button UP> Send Learn Scene TriggerDisable/Enable1 Bit1.3 enableCW
1<Button UP> Sequence Command B0-100%1 Byte5.1 percentage (0..100%)CRT
1<Button UP> Sequence Command BHVAC Mode1 Byte20.102 HVAC modeCRT
1<Button UP> Sequence Command B0-2551 Byte5.10 counter pulses (0..255)CRT
1<Button UP> Sequence Command BOff/On1 Bit1.1 switchCRT
1<Button UP> ShutterStep/Stop1 Bit1.7 stepCRT
1<Button UP> DimmingDimming Control4 Bit3.7 dimming controlCRT
1<Button UP> Release Action0-100%1 Byte5.1 percentage (0..100%)CRT
1<Button UP> Release Action0-2551 Byte5.10 counter pulses (0..255)CRT
1<Button UP> Long Press0-100%1 Byte5.1 percentage (0..100%)CRT
1<Button UP> Long PressHVAC Mode1 Byte20.102 HVAC modeCRT
1<Button UP> Long Press0-2551 Byte5.10 counter pulses (0..255)CRT
1<Button UP> Long PressOff/On1 Bit1.1 switchCRWT
1<Button UP> Release ActionOff/On1 Bit1.1 switchCRWT
1<Button UP> Green0-2551 Byte5.10 counter pulses (0..255)CRT
1<Button UP> Release ActionHVAC Mode1 Byte20.102 HVAC modeCRT
2<Button UP> Sequence Command COff/On1 Bit1.1 switchCRT
2<Button UP> Sequence Command C0-100%1 Byte5.1 percentage (0..100%)CRT
2<Button UP> Sequence Command CHVAC Mode1 Byte20.102 HVAC modeCRT
2<Button UP> Sequence Command C0-2551 Byte5.10 counter pulses (0..255)CRT
2<Button UP> FeedbackOff/On1 Bit1.1 switchCW
2<Button UP> FeedbackUp/Down1 Bit1.8 up/downCW
2<Button UP> Blue0-2551 Byte5.10 counter pulses (0..255)CRT
3<Button RIGHT> Press ActionOff/On1 Bit1.1 switchCRWT
3<Button RIGHT> Press Action0-2551 Byte5.10 counter pulses (0..255)CRT
3<Button RIGHT> Press Action0-100%1 Byte5.1 percentage (0..100%)CRT
3<Button RIGHT> Press ActionHVAC Mode1 Byte20.102 HVAC modeCRT
3<Button RIGHT> Press - Release ActionOff/On1 Bit1.1 switchCRWT
3<Button RIGHT> Press - Release Action0-2551 Byte5.10 counter pulses (0..255)CRT
3<Button RIGHT> Press - Release Action0-100%1 Byte5.1 percentage (0..100%)CRT
3<Button RIGHT> Press - Release ActionHVAC Mode1 Byte20.102 HVAC modeCRT
3<Button RIGHT> Short - Long PressOff/On1 Bit1.1 switchCRWT
3<Button RIGHT> Short - Long Press0-2551 Byte5.10 counter pulses (0..255)CRT
3<Button RIGHT> Short - Long Press0-100%1 Byte5.1 percentage (0..100%)CRT
3<Button RIGHT> Short - Long PressHVAC Mode1 Byte20.102 HVAC modeCRT
3<Button RIGHT> Dimmer On/OffOff/On1 Bit1.1 switchCRWT
3<Button RIGHT> ShutterUp/Down1 Bit1.8 up/downCRWT
3<Button RIGHT> Recall/Learn SceneScene1 Byte18.1 scene controlCRT
3<Button RIGHT> Sequence Command AOff/On1 Bit1.1 switchCRT
3<Button RIGHT> Sequence Command A0-2551 Byte5.10 counter pulses (0..255)CRT
3<Button RIGHT> Sequence Command A0-100%1 Byte5.1 percentage (0..100%)CRT
3<Button RIGHT> Sequence Command AHVAC Mode1 Byte20.102 HVAC modeCRT
3<Button RIGHT> Red0-2551 Byte5.10 counter pulses (0..255)CRT
4<Button RIGHT> Release ActionOff/On1 Bit1.1 switchCRWT
4<Button RIGHT> Release Action0-2551 Byte5.10 counter pulses (0..255)CRT
4<Button RIGHT> Release Action0-100%1 Byte5.1 percentage (0..100%)CRT
4<Button RIGHT> Long PressOff/On1 Bit1.1 switchCRWT
4<Button RIGHT> Long Press0-2551 Byte5.10 counter pulses (0..255)CRT
4<Button RIGHT> Long Press0-100%1 Byte5.1 percentage (0..100%)CRT
4<Button RIGHT> Long PressHVAC Mode1 Byte20.102 HVAC modeCRT
4<Button RIGHT> DimmingDimming Control4 Bit3.7 dimming controlCRT
4<Button RIGHT> ShutterStep/Stop1 Bit1.7 stepCRT
4<Button RIGHT> Send Learn Scene TriggerDisable/Enable1 Bit1.3 enableCW
4<Button RIGHT> Sequence Command BOff/On1 Bit1.1 switchCRT
4<Button RIGHT> Sequence Command B0-2551 Byte5.10 counter pulses (0..255)CRT
4<Button RIGHT> Sequence Command B0-100%1 Byte5.1 percentage (0..100%)CRT
4<Button RIGHT> Sequence Command BHVAC Mode1 Byte20.102 HVAC modeCRT
4<Button RIGHT> Green0-2551 Byte5.10 counter pulses (0..255)CRT
4<Button RIGHT> Release ActionHVAC Mode1 Byte20.102 HVAC modeCRT
5<Button RIGHT> FeedbackOff/On1 Bit1.1 switchCW
5<Button RIGHT> FeedbackUp/Down1 Bit1.8 up/downCW
5<Button RIGHT> Sequence Command COff/On1 Bit1.1 switchCRT
5<Button RIGHT> Sequence Command C0-2551 Byte5.10 counter pulses (0..255)CRT
5<Button RIGHT> Sequence Command C0-100%1 Byte5.1 percentage (0..100%)CRT
5<Button RIGHT> Sequence Command CHVAC Mode1 Byte20.102 HVAC modeCRT
5<Button RIGHT> Blue0-2551 Byte5.10 counter pulses (0..255)CRT
6<Button DOWN> Press ActionOff/On1 Bit1.1 switchCRWT
6<Button DOWN> Press Action0-2551 Byte5.10 counter pulses (0..255)CRT
6<Button DOWN> Press Action0-100%1 Byte5.1 percentage (0..100%)CRT
6<Button DOWN> Press ActionHVAC Mode1 Byte20.102 HVAC modeCRT
6<Button DOWN> Press - Release ActionOff/On1 Bit1.1 switchCRWT
6<Button DOWN> Press - Release Action0-2551 Byte5.10 counter pulses (0..255)CRT
6<Button DOWN> Press - Release Action0-100%1 Byte5.1 percentage (0..100%)CRT
6<Button DOWN> Press - Release ActionHVAC Mode1 Byte20.102 HVAC modeCRT
6<Button DOWN> Short - Long PressOff/On1 Bit1.1 switchCRWT
6<Button DOWN> Short - Long Press0-2551 Byte5.10 counter pulses (0..255)CRT
6<Button DOWN> Short - Long Press0-100%1 Byte5.1 percentage (0..100%)CRT
6<Button DOWN> Short - Long PressHVAC Mode1 Byte20.102 HVAC modeCRT
6<Button DOWN> Dimmer On/OffOff/On1 Bit1.1 switchCRWT
6<Button DOWN> ShutterUp/Down1 Bit1.8 up/downCRWT
6<Button DOWN> Recall/Learn SceneScene1 Byte18.1 scene controlCRT
6<Button DOWN> Sequence Command AOff/On1 Bit1.1 switchCRT
6<Button DOWN> Sequence Command A0-2551 Byte5.10 counter pulses (0..255)CRT
6<Button DOWN> Sequence Command A0-100%1 Byte5.1 percentage (0..100%)CRT
6<Button DOWN> Sequence Command AHVAC Mode1 Byte20.102 HVAC modeCRT
6<Button DOWN> Red0-2551 Byte5.10 counter pulses (0..255)CRT
7<Button DOWN> Release ActionOff/On1 Bit1.1 switchCRWT
7<Button DOWN> Release Action0-2551 Byte5.10 counter pulses (0..255)CRT
7<Button DOWN> Release Action0-100%1 Byte5.1 percentage (0..100%)CRT
7<Button DOWN> Long PressOff/On1 Bit1.1 switchCRWT
7<Button DOWN> Long Press0-2551 Byte5.10 counter pulses (0..255)CRT
7<Button DOWN> Long Press0-100%1 Byte5.1 percentage (0..100%)CRT
7<Button DOWN> Long PressHVAC Mode1 Byte20.102 HVAC modeCRT
7<Button DOWN> DimmingDimming Control4 Bit3.7 dimming controlCRT
7<Button DOWN> ShutterStep/Stop1 Bit1.7 stepCRT
7<Button DOWN> Send Learn Scene TriggerDisable/Enable1 Bit1.3 enableCW
7<Button DOWN> Sequence Command BOff/On1 Bit1.1 switchCRT
7<Button DOWN> Sequence Command B0-2551 Byte5.10 counter pulses (0..255)CRT
7<Button DOWN> Sequence Command B0-100%1 Byte5.1 percentage (0..100%)CRT
7<Button DOWN> Sequence Command BHVAC Mode1 Byte20.102 HVAC modeCRT
7<Button DOWN> Green0-2551 Byte5.10 counter pulses (0..255)CRT
7<Button DOWN> Release ActionHVAC Mode1 Byte20.102 HVAC modeCRT
8<Button DOWN> FeedbackOff/On1 Bit1.1 switchCW
8<Button DOWN> FeedbackUp/Down1 Bit1.8 up/downCW
8<Button DOWN> Sequence Command COff/On1 Bit1.1 switchCRT
8<Button DOWN> Sequence Command C0-2551 Byte5.10 counter pulses (0..255)CRT
8<Button DOWN> Sequence Command C0-100%1 Byte5.1 percentage (0..100%)CRT
8<Button DOWN> Sequence Command CHVAC Mode1 Byte20.102 HVAC modeCRT
8<Button DOWN> Blue0-2551 Byte5.10 counter pulses (0..255)CRT
9<Button LEFT> Press ActionOff/On1 Bit1.1 switchCRWT
9<Button LEFT> Press Action0-2551 Byte5.10 counter pulses (0..255)CRT
9<Button LEFT> Press Action0-100%1 Byte5.1 percentage (0..100%)CRT
9<Button LEFT> Press ActionHVAC Mode1 Byte20.102 HVAC modeCRT
9<Button LEFT> Press - Release ActionOff/On1 Bit1.1 switchCRWT
9<Button LEFT> Press - Release Action0-2551 Byte5.10 counter pulses (0..255)CRT
9<Button LEFT> Press - Release Action0-100%1 Byte5.1 percentage (0..100%)CRT
9<Button LEFT> Press - Release ActionHVAC Mode1 Byte20.102 HVAC modeCRT
9<Button LEFT> Short - Long PressOff/On1 Bit1.1 switchCRWT
9<Button LEFT> Short - Long Press0-2551 Byte5.10 counter pulses (0..255)CRT
9<Button LEFT> Short - Long Press0-100%1 Byte5.1 percentage (0..100%)CRT
9<Button LEFT> Short - Long PressHVAC Mode1 Byte20.102 HVAC modeCRT
9<Button LEFT> Dimmer On/OffOff/On1 Bit1.1 switchCRWT
9<Button LEFT> ShutterUp/Down1 Bit1.8 up/downCRWT
9<Button LEFT> Recall/Learn SceneScene1 Byte18.1 scene controlCRT
9<Button LEFT> Sequence Command AOff/On1 Bit1.1 switchCRT
9<Button LEFT> Sequence Command A0-2551 Byte5.10 counter pulses (0..255)CRT
9<Button LEFT> Sequence Command A0-100%1 Byte5.1 percentage (0..100%)CRT
9<Button LEFT> Sequence Command AHVAC Mode1 Byte20.102 HVAC modeCRT
9<Button LEFT> Red0-2551 Byte5.10 counter pulses (0..255)CRT
10<Button LEFT> Release ActionOff/On1 Bit1.1 switchCRWT
10<Button LEFT> Release Action0-2551 Byte5.10 counter pulses (0..255)CRT
10<Button LEFT> Release Action0-100%1 Byte5.1 percentage (0..100%)CRT
10<Button LEFT> Long PressOff/On1 Bit1.1 switchCRWT
10<Button LEFT> Long Press0-2551 Byte5.10 counter pulses (0..255)CRT
10<Button LEFT> Long Press0-100%1 Byte5.1 percentage (0..100%)CRT
10<Button LEFT> Long PressHVAC Mode1 Byte20.102 HVAC modeCRT
10<Button LEFT> DimmingDimming Control4 Bit3.7 dimming controlCRT
10<Button LEFT> ShutterStep/Stop1 Bit1.7 stepCRT
10<Button LEFT> Send Learn Scene TriggerDisable/Enable1 Bit1.3 enableCW
10<Button LEFT> Sequence Command BOff/On1 Bit1.1 switchCRT
10<Button LEFT> Sequence Command B0-2551 Byte5.10 counter pulses (0..255)CRT
10<Button LEFT> Sequence Command B0-100%1 Byte5.1 percentage (0..100%)CRT
10<Button LEFT> Sequence Command BHVAC Mode1 Byte20.102 HVAC modeCRT
10<Button LEFT> Green0-2551 Byte5.10 counter pulses (0..255)CRT
10<Button LEFT> Release ActionHVAC Mode1 Byte20.102 HVAC modeCRT
11<Button LEFT> FeedbackOff/On1 Bit1.1 switchCW
11<Button LEFT> FeedbackUp/Down1 Bit1.8 up/downCW
11<Button LEFT> Sequence Command COff/On1 Bit1.1 switchCRT
11<Button LEFT> Sequence Command C0-2551 Byte5.10 counter pulses (0..255)CRT
11<Button LEFT> Sequence Command C0-100%1 Byte5.1 percentage (0..100%)CRT
11<Button LEFT> Sequence Command CHVAC Mode1 Byte20.102 HVAC modeCRT
11<Button LEFT> Blue0-2551 Byte5.10 counter pulses (0..255)CRT
12<Temperature> Actual TemperatureValue °C2 Bytes9.1 temperature (°C)CRT
12<Input> Press ActionOff/On1 Bit1.1 switchCRWT
12<Input> Press Action0-2551 Byte5.10 counter pulses (0..255)CRT
12<Input> Press Action0-100%1 Byte5.1 percentage (0..100%)CRT
12<Input> Press ActionHVAC Mode1 Byte20.102 HVAC modeCRT
12<Input> Press - Release ActionOff/On1 Bit1.1 switchCRWT
12<Input> Press - Release Action0-2551 Byte5.10 counter pulses (0..255)CRT
12<Input> Press - Release Action0-100%1 Byte5.1 percentage (0..100%)CRT
12<Input> Press - Release ActionHVAC Mode1 Byte20.102 HVAC modeCRT
12<Input> Short - Long PressOff/On1 Bit1.1 switchCRWT
12<Input> Short - Long Press0-2551 Byte5.10 counter pulses (0..255)CRT
12<Input> Short - Long Press0-100%1 Byte5.1 percentage (0..100%)CRT
12<Input> Short - Long PressHVAC Mode1 Byte20.102 HVAC modeCRT
12<Input> Dimmer On/OffOff/On1 Bit1.1 switchCRWT
12<Input> ShutterUp/Down1 Bit1.8 up/downCRWT
12<Input> Recall/Learn SceneScene1 Byte18.1 scene controlCRT
12<Input> Sequence Command AOff/On1 Bit1.1 switchCRT
12<Input> Sequence Command A0-2551 Byte5.10 counter pulses (0..255)CRT
12<Input> Sequence Command A0-100%1 Byte5.1 percentage (0..100%)CRT
12<Input> Sequence Command AHVAC Mode1 Byte20.102 HVAC modeCRT
12<Input> Red0-2551 Byte5.10 counter pulses (0..255)CRT
13<Temperature> KNX Probe TemperatureValue °C2 Bytes9.1 temperature (°C)CW
13<Input> Release ActionOff/On1 Bit1.1 switchCRWT
13<Input> Release Action0-2551 Byte5.10 counter pulses (0..255)CRT
13<Input> Release Action0-100%1 Byte5.1 percentage (0..100%)CRT
13<Input> Long PressOff/On1 Bit1.1 switchCRWT
13<Input> Long Press0-2551 Byte5.10 counter pulses (0..255)CRT
13<Input> Long Press0-100%1 Byte5.1 percentage (0..100%)CRT
13<Input> Long PressHVAC Mode1 Byte20.102 HVAC modeCRT
13<Input> DimmingDimming Control4 Bit3.7 dimming controlCRT
13<Input> ShutterStep/Stop1 Bit1.7 stepCRT
13<Input> Send Learn Scene TriggerDisable/Enable1 Bit1.3 enableCW
13<Input> Sequence Command BOff/On1 Bit1.1 switchCRT
13<Input> Sequence Command B0-2551 Byte5.10 counter pulses (0..255)CRT
13<Input> Sequence Command B0-100%1 Byte5.1 percentage (0..100%)CRT
13<Input> Sequence Command BHVAC Mode1 Byte20.102 HVAC modeCRT
13<Input> Green0-2551 Byte5.10 counter pulses (0..255)CRT
13<Input> Release ActionHVAC Mode1 Byte20.102 HVAC modeCRT
14<T. Sensor> Trigger T1Off/On1 Bit1.1 switchCRT
14<Thermostat> Heat/Cool ModeHeat/Cool1 Bit1.100 heating/coolingCW
14<Thermostat> Heat/Cool ModeHeat/Cool1 Bit1.100 heating/coolingCRT
14<Input> FeedbackOff/On1 Bit1.1 switchCW
14<Input> FeedbackUp/Down1 Bit1.8 up/downCW
14<Input> Sequence Command COff/On1 Bit1.1 switchCRT
14<Input> Sequence Command C0-2551 Byte5.10 counter pulses (0..255)CRT
14<Input> Sequence Command C0-100%1 Byte5.1 percentage (0..100%)CRT
14<Input> Sequence Command CHVAC Mode1 Byte20.102 HVAC modeCRT
14<Input> Blue0-2551 Byte5.10 counter pulses (0..255)CRT
15<T. Sensor> Trigger T2Off/On1 Bit1.1 switchCRT
15<Thermostat> Window ContactClose/Open1 Bit1.19 window/doorCW
16<T. Sensor> Enable Trigger T1/T2Disable/Enable1 Bit1.3 enableCW
16<Thermostat> Comfort ModeOff/On1 Bit1.1 switchCW
17<Thermostat> HVAC ModeComf/Standby/Eco/B.protection1 Byte20.102 HVAC modeCW
18<Thermostat> Actual SetpointValue °C2 Bytes9.1 temperature (°C)CRT
19<Thermostat> Setpoint AdjustmentValue °C2 Bytes9.1 temperature (°C)CW
19<Thermostat> Setpoint AdjustmentValue °C1 Bit1.7 stepCW
20<Thermostat> SP Economy HeatingValue °C2 Bytes9.1 temperature (°C)CW
20<Thermostat> SP EconomyValue °C2 Bytes9.1 temperature (°C)CW
20<Thermostat> Base SetpointValue °C2 Bytes9.1 temperature (°C)CW
21<Thermostat> SP Standby HeatingValue °C2 Bytes9.1 temperature (°C)CW
21<Thermostat> SP StandbyValue °C2 Bytes9.1 temperature (°C)CW
22<Thermostat> SP Comfort HeatingValue °C2 Bytes9.1 temperature (°C)CW
22<Thermostat> SP ComfortValue °C2 Bytes9.1 temperature (°C)CW
23<Thermostat> SP Economy CoolingValue °C2 Bytes9.1 temperature (°C)CW
24<Thermostat> SP Standby CoolingValue °C2 Bytes9.1 temperature (°C)CW
25<Thermostat> SP Comfort CoolingValue °C2 Bytes9.1 temperature (°C)CW
26<Thermostat> HeatingOff/On1 Bit1.1 switchCRT
26<Thermostat> Heating0-100%1 Byte5.1 percentage (0..100%)CRT
26<Fan Coil> Heating ValveOff/On1 Bit1.1 switchCRT
26<Fan Coil> Heating/Cooling ValveOff/On1 Bit1.1 switchCRT
27<Thermostat> CoolingOff/On1 Bit1.1 switchCRT
27<Thermostat> Cooling0-100%1 Byte5.1 percentage (0..100%)CRT
27<Fan Coil> Cooling ValveOff/On1 Bit1.1 switchCRT
28<Thermostat> Off/On 2nd Stage HeatingOff/On1 Bit1.1 switchCRT
29<Thermostat> Off/On 2nd Stage CoolingOff/On1 Bit1.1 switchCRT
30<Fan Coil> Speed 1Off/On1 Bit1.1 switchCRT
30<Fan Coil> Continuous Control %0-100%1 Byte5.1 percentage (0..100%)CRT
30<Fan Coil> Speed 1 HeatingOff/On1 Bit1.1 switchCRT
30<Fan Coil> Speed 1 CoolingOff/On1 Bit1.1 switchCRT
30<Fan Coil> Continuous Control % Heating0-100%1 Byte5.1 percentage (0..100%)CRT
30<Fan Coil> Continuous Control % Cooling0-100%1 Byte5.1 percentage (0..100%)CRT
31<Fan Coil> Speed 2Off/On1 Bit1.1 switchCRT
31<Fan Coil> Speed 2 HeatingOff/On1 Bit1.1 switchCRT
31<Fan Coil> Speed 2 CoolingOff/On1 Bit1.1 switchCRT
32<Fan Coil> Speed 3Off/On1 Bit1.1 switchCRT
32<Fan Coil> Speed 3 HeatingOff/On1 Bit1.1 switchCRT
32<Fan Coil> Speed 3 CoolingOff/On1 Bit1.1 switchCRT
33<Fan Coil> Set Man/Auto ModeManual (0) / Auto (1)1 Bit1.1 switchCW
34<Fan Coil> Force Value in Man Mode Speed 1Off/On1 Bit1.1 switchCW
34<Fan Coil> Force Speed Control in Man Mode0-100%1 Byte5.1 percentage (0..100%)CW
35<Fan Coil> Force Value in Man Mode Speed 2Off/On1 Bit1.1 switchCW
36<Fan Coil> Force Value in Man Mode Speed 3Off/On1 Bit1.1 switchCW
37<Thermostat> OFF ThermostatOff/On1 Bit1.1 switchCW
39<Additional Valve> Percentage0-100%1 Byte5.1 percentage (0..100%)CRT
39<Additional Valve> PWMOff/On1 Bit1.1 switchCRT
40<Thermostat> Temperature AlarmOff/On1 Bit1.1 switchCRT
42<RGB LED> Off/OnOff/On1 Bit1.1 switchCW
42<RGB LED> Feedback KNX 1Off/On1 Bit1.1 switchCW
42<RGB LED> Physical dimension1 Byte Signed1 ByteDPT.6CW
42<RGB LED> Physical dimension1 Byte Unsigned1 ByteDPT.5CW
42<RGB LED> Physical dimension2 Byte signed2 BytesDPT.8CW
42<RGB LED> Physical dimension2 Bytes Unsigned2 BytesDPT.7CW
42<RGB LED> Physical dimension2 Byte float2 BytesDPT.9CW
42<RGB LED> Physical dimension4 Bytes Signed4 BytesDPT.13CW
42<RGB LED> Physical dimension4 Bytes Float4 BytesDPT.14CW
42<RGB LED> Physical dimension4 Bytes Unsigned4 BytesDPT.12CW
42<RGB LED> Physical dimensionTemperature2 Bytes9.1 temperature (°C)CW
42<RGB LED> Physical dimensionPower4 Bytes14.56 power (W)CW
42<RGB LED> Physical dimensionEnergy4 Bytes13.13 active energy (kWh)CW
42<RGB LED> Physical dimension0-100%1 Byte5.1 percentage (0..100%)CW
42<RGB LED> Stop color loopStop-Start1 Bit1.10 start/stopCW
43<RGB LED> Red Component0-100%1 Byte5.1 percentage (0..100%)CW
43<RGB LED> Feedback KNX 2Off/On1 Bit1.1 switchCW
44<RGB LED> Green Component0-100%1 Byte5.1 percentage (0..100%)CW
44<RGB LED> Feedback KNX 3Off/On1 Bit1.1 switchCW
45<RGB LED> Blue Component0-100%1 Byte5.1 percentage (0..100%)CW
45<RGB LED> Feedback KNX 4Off/On1 Bit1.1 switchCW
46<RGB LED> RGB ComponentRGB Color3 Bytes232.600 RGB value 3x(0..255)CW
46<RGB LED> Feedback KNX 5Off/On1 Bit1.1 switchCW
47<RGB LED> Night ModeOff/On1 Bit1.1 switchCW
47<RGB LED> Brightness0-100%1 Byte5.1 percentage (0..100%)CW
48<RGB LED> Step Light ModeOff/On1 Bit1.1 switchCW
50<Logic 1> Output1 Byte1 Byte5.10 counter pulses (0..255)CRT
50<Logic 1> OutputLogic1 Bit1.2 booleanCRT
50<Logic 1> Output1 Bit1 Bit1.2 booleanCRT
50<Logic 1> Output 4Byte CountOutput 4Byte Count4 Bytes13.1 counter pulses (signed)CRT
50<Logic 1> Output 4Byte UCountOutput 4Byte UCount4 Bytes12.1 counter pulses (unsigned)CRT
50<Logic 1> Output 4Byte FloatOutput 4Byte Float4 Bytes14.56 power (W)CRT
50<Logic 1> Output 2Byte CountOutput 2Byte Count2 Bytes8.1 pulses differenceCRT
50<Logic 1> Output 2Byte UCountOutput 2Byte UCount2 Bytes7.1 pulsesCRT
50<Logic 1> Output 2Byte FloatOutput 2Byte Float2 Bytes9.1 temperature (°C)CRT
50<Logic 1> Output CountOutput Count1 Byte6.10 counter pulses (-128..127)CRT
50<Logic 1> Output UCountOutput UCount1 Byte5.10 counter pulses (0..255)CRT
50<Logic 1> Output BitOutput Bit1 Bit1.2 booleanCRT
51<Logic 1> Input1 Byte1 Byte5.10 counter pulses (0..255)CW
51<Logic 1> InputLogic1 Bit1.2 booleanCW
51<Logic 1> Input ALogic1 Bit1.2 booleanCW
51<Logic 1> Input1 Bit1 Bit1.2 booleanCW
51<Logic 1> Input2 Bytes2 Bytes9.1 temperature (°C)CW
51<Logic 1> Input4 Bytes4 Bytes14.56 power (W)CW
51<Logic 1> Input A 4Byte CountInput A 4Byte Count4 Bytes13.1 counter pulses (signed)CW
51<Logic 1> Input A 4Byte UCountInput A 4Byte UCount4 Bytes12.1 counter pulses (unsigned)CW
51<Logic 1> Input A 4Byte FloatInput A 4Byte Float4 Bytes14.56 power (W)CW
51<Logic 1> Input A 2Byte CountInput A 2Byte Count2 Bytes8.1 pulses differenceCW
51<Logic 1> Input A 2Byte UCountInput A 2Byte UCount2 Bytes7.1 pulsesCW
51<Logic 1> Input A 2Byte FloatInput A 2Byte Float2 Bytes9.1 temperature (°C)CW
51<Logic 1> Input A CountInput A Count1 Byte6.10 counter pulses (-128..127)CW
51<Logic 1> Input A UCountInput A UCount1 Byte5.10 counter pulses (0..255)CW
51<Logic 1> Input A BitInput A Bit1 Bit1.2 booleanCW
52<Logic 1> Input BLogic1 Bit1.2 booleanCW
52<Logic 1> Input B 4Byte FloatInput B 4Byte Float4 Bytes13.1 counter pulses (signed)CW
52<Logic 1> Input B 4Byte CountInput B 4Byte Count4 Bytes12.1 counter pulses (unsigned)CW
52<Logic 1> Input B 4Byte UCountInput B 4Byte UCount4 Bytes14.56 power (W)CW
52<Logic 1> Input B 2Byte CountInput B 2Byte Count2 Bytes8.1 pulses differenceCW
52<Logic 1> Input B 2Byte UCountInput B 2Byte UCount2 Bytes7.1 pulsesCW
52<Logic 1> Input B 2Byte FloatInput B 2Byte Float2 Bytes9.1 temperature (°C)CW
52<Logic 1> Input B CountInput B Count1 Byte6.10 counter pulses (-128..127)CW
52<Logic 1> Input B UCountInput B UCount1 Byte5.10 counter pulses (0..255)CW
52<Logic 1> Input B BitInput B Bit1 Bit1.2 booleanCW
53<Logic 1> Input C 4Byte FloatInput C 4Byte Float4 Bytes13.1 counter pulses (signed)CW
53<Logic 1> Input C 4Byte CountInput C 4Byte Count4 Bytes12.1 counter pulses (unsigned)CW
53<Logic 1> Input C 4Byte UCountInput C 4Byte UCount4 Bytes14.56 power (W)CW
53<Logic 1> Input C 2Byte CountInput C 2Byte Count2 Bytes8.1 pulses differenceCW
53<Logic 1> Input C 2Byte UCountInput C 2Byte UCount2 Bytes7.1 pulsesCW
53<Logic 1> Input C 2Byte FloatInput C 2Byte Float2 Bytes9.1 temperature (°C)CW
53<Logic 1> Input C CountInput C Count1 Byte6.10 counter pulses (-128..127)CW
53<Logic 1> Input C UCountInput C UCount1 Byte5.10 counter pulses (0..255)CW
53<Logic 1> Input C BitInput C Bit1 Bit1.2 booleanCW
54<Logic 1> Input D 4Byte FloatInput D 4Byte Float4 Bytes13.1 counter pulses (signed)CW
54<Logic 1> Input D 4Byte CountInput D 4Byte Count4 Bytes12.1 counter pulses (unsigned)CW
54<Logic 1> Input D 4Byte UCountInput D 4Byte UCount4 Bytes14.56 power (W)CW
54<Logic 1> Input D 2Byte CountInput D 2Byte Count2 Bytes8.1 pulses differenceCW
54<Logic 1> Input D 2Byte UCountInput D 2Byte UCount2 Bytes7.1 pulsesCW
54<Logic 1> Input D 2Byte FloatInput D 2Byte Float2 Bytes9.1 temperature (°C)CW
54<Logic 1> Input D CountInput D Count1 Byte6.10 counter pulses (-128..127)CW
54<Logic 1> Input D UCountInput D UCount1 Byte5.10 counter pulses (0..255)CW
54<Logic 1> Input D BitInput D Bit1 Bit1.2 booleanCW
55<Logic 2> OutputLogic1 Bit1.2 booleanCRT
55<Logic 2> Output1 Byte1 Byte5.10 counter pulses (0..255)CRT
55<Logic 2> Output1 Bit1 Bit1.2 booleanCRT
55<Logic 2> Output 4Byte CountOutput 4Byte Count4 Bytes13.1 counter pulses (signed)CRT
55<Logic 2> Output 4Byte UCountOutput 4Byte UCount4 Bytes12.1 counter pulses (unsigned)CRT
55<Logic 2> Output 4Byte FloatOutput 4Byte Float4 Bytes14.56 power (W)CRT
55<Logic 2> Output 2Byte CountOutput 2Byte Count2 Bytes8.1 pulses differenceCRT
55<Logic 2> Output 2Byte UCountOutput 2Byte UCount2 Bytes7.1 pulsesCRT
55<Logic 2> Output 2Byte FloatOutput 2Byte Float2 Bytes9.1 temperature (°C)CRT
55<Logic 2> Output CountOutput Count1 Byte6.10 counter pulses (-128..127)CRT
55<Logic 2> Output UCountOutput UCount1 Byte5.10 counter pulses (0..255)CRT
55<Logic 2> Output BitOutput Bit1 Bit1.2 booleanCRT
55<VH> Room BookedRoom Booked1 Bit1.2 booleanCW
56<Logic 2> InputLogic1 Bit1.2 booleanCW
56<Logic 2> Input1 Byte1 Byte5.10 counter pulses (0..255)CW
56<Logic 2> Input ALogic1 Bit1.2 booleanCW
56<Logic 2> Input1 Bit1 Bit1.2 booleanCW
56<Logic 2> Input2 Bytes2 Bytes9.1 temperature (°C)CW
56<Logic 2> Input4 Bytes4 Bytes14.56 power (W)CW
56<Logic 2> Input A 4Byte CountInput A 4Byte Count4 Bytes13.1 counter pulses (signed)CW
56<Logic 2> Input A 4Byte UCountInput A 4Byte UCount4 Bytes12.1 counter pulses (unsigned)CW
56<Logic 2> Input A 4Byte FloatInput A 4Byte Float4 Bytes14.56 power (W)CW
56<Logic 2> Input A 2Byte CountInput A 2Byte Count2 Bytes8.1 pulses differenceCW
56<Logic 2> Input A 2Byte UCountInput A 2Byte UCount2 Bytes7.1 pulsesCW
56<Logic 2> Input A 2Byte FloatInput A 2Byte Float2 Bytes9.1 temperature (°C)CW
56<Logic 2> Input A CountInput A Count1 Byte6.10 counter pulses (-128..127)CW
56<Logic 2> Input A UCountInput A UCount1 Byte5.10 counter pulses (0..255)CW
56<Logic 2> Input A BitInput A Bit1 Bit1.2 booleanCW
56<VH> Remote Inputs Enable (Global Enable)Remote Inputs Enable (Global Enable)1 Bit1.2 booleanCW
57<Logic 2> Input BLogic1 Bit1.2 booleanCW
57<Logic 2> Input B 4Byte CountInput B 4Byte Count4 Bytes12.1 counter pulses (unsigned)CW
57<Logic 2> Input B 4Byte UCountInput B 4Byte UCount4 Bytes14.56 power (W)CW
57<Logic 2> Input B 4Byte FloatInput B 4Byte Float4 Bytes13.1 counter pulses (signed)CW
57<Logic 2> Input B 2Byte CountInput B 2Byte Count2 Bytes8.1 pulses differenceCW
57<Logic 2> Input B 2Byte UCountInput B 2Byte UCount2 Bytes7.1 pulsesCW
57<Logic 2> Input B 2Byte FloatInput B 2Byte Float2 Bytes9.1 temperature (°C)CW
57<Logic 2> Input B CountInput B Count1 Byte6.10 counter pulses (-128..127)CW
57<Logic 2> Input B UCountInput B UCount1 Byte5.10 counter pulses (0..255)CW
57<Logic 2> Input B BitInput B Bit1 Bit1.2 booleanCW
57<VH> Presence OutputPresence Output1 Bit1.2 booleanCRT
58<Logic 2> Input C 4Byte CountInput C 4Byte Count4 Bytes12.1 counter pulses (unsigned)CW
58<Logic 2> Input C 4Byte UCountInput C 4Byte UCount4 Bytes14.56 power (W)CW
58<Logic 2> Input C 4Byte FloatInput C 4Byte Float4 Bytes13.1 counter pulses (signed)CW
58<Logic 2> Input C 2Byte CountInput C 2Byte Count2 Bytes8.1 pulses differenceCW
58<Logic 2> Input C 2Byte UCountInput C 2Byte UCount2 Bytes7.1 pulsesCW
58<Logic 2> Input C 2Byte FloatInput C 2Byte Float2 Bytes9.1 temperature (°C)CW
58<Logic 2> Input C CountInput C Count1 Byte6.10 counter pulses (-128..127)CW
58<Logic 2> Input C UCountInput C UCount1 Byte5.10 counter pulses (0..255)CW
58<Logic 2> Input C BitInput C Bit1 Bit1.2 booleanCW
58<VH> HVAC OutputHVAC Output1 Byte20.102 HVAC modeCRT
59<Logic 2> Input D 4Byte CountInput D 4Byte Count4 Bytes12.1 counter pulses (unsigned)CW
59<Logic 2> Input D 4Byte UCountInput D 4Byte UCount4 Bytes14.56 power (W)CW
59<Logic 2> Input D 4Byte FloatInput D 4Byte Float4 Bytes13.1 counter pulses (signed)CW
59<Logic 2> Input D 2Byte CountInput D 2Byte Count2 Bytes8.1 pulses differenceCW
59<Logic 2> Input D 2Byte UCountInput D 2Byte UCount2 Bytes7.1 pulsesCW
59<Logic 2> Input D 2Byte FloatInput D 2Byte Float2 Bytes9.1 temperature (°C)CW
59<Logic 2> Input D CountInput D Count1 Byte6.10 counter pulses (-128..127)CW
59<Logic 2> Input D UCountInput D UCount1 Byte5.10 counter pulses (0..255)CW
59<Logic 2> Input D BitInput D Bit1 Bit1.2 booleanCW
59<VH> Additional OutputAdditional Output1 Byte5.10 counter pulses (0..255)CRT
60<Logic 3> OutputLogic1 Bit1.2 booleanCRT
60<Logic 3> Output1 Byte1 Byte5.10 counter pulses (0..255)CRT
60<Logic 3> Output1 Bit1 Bit1.2 booleanCRT
60<Logic 3> Output 4Byte CountOutput 4Byte Count4 Bytes13.1 counter pulses (signed)CRT
60<Logic 3> Output 4Byte UCountOutput 4Byte UCount4 Bytes12.1 counter pulses (unsigned)CRT
60<Logic 3> Output 4Byte FloatOutput 4Byte Float4 Bytes14.56 power (W)CRT
60<Logic 3> Output 2Byte CountOutput 2Byte Count2 Bytes8.1 pulses differenceCRT
60<Logic 3> Output 2Byte UCountOutput 2Byte UCount2 Bytes7.1 pulsesCRT
60<Logic 3> Output 2Byte FloatOutput 2Byte Float2 Bytes9.1 temperature (°C)CRT
60<Logic 3> Output CountOutput Count1 Byte6.10 counter pulses (-128..127)CRT
60<Logic 3> Output UCountOutput UCount1 Byte5.10 counter pulses (0..255)CRT
60<Logic 3> Output BitOutput Bit1 Bit1.2 booleanCRT
61<Logic 3> InputLogic1 Bit1.2 booleanCW
61<Logic 3> Input1 Byte1 Byte5.10 counter pulses (0..255)CW
61<Logic 3> Input ALogic1 Bit1.2 booleanCW
61<Logic 3> Input1 Bit1 Bit1.2 booleanCW
61<Logic 3> Input2 Bytes2 Bytes9.1 temperature (°C)CW
61<Logic 3> Input4 Bytes4 Bytes14.56 power (W)CW
61<Logic 3> Input A 4Byte CountInput A 4Byte Count4 Bytes13.1 counter pulses (signed)CW
61<Logic 3> Input A 4Byte UCountInput A 4Byte UCount4 Bytes12.1 counter pulses (unsigned)CW
61<Logic 3> Input A 4Byte FloatInput A 4Byte Float4 Bytes14.56 power (W)CW
61<Logic 3> Input A 2Byte CountInput A 2Byte Count2 Bytes8.1 pulses differenceCW
61<Logic 3> Input A 2Byte UCountInput A 2Byte UCount2 Bytes7.1 pulsesCW
61<Logic 3> Input A 2Byte FloatInput A 2Byte Float2 Bytes9.1 temperature (°C)CW
61<Logic 3> Input A CountInput A Count1 Byte6.10 counter pulses (-128..127)CW
61<Logic 3> Input A UCountInput A UCount1 Byte5.10 counter pulses (0..255)CW
61<Logic 3> Input A BitInput A Bit1 Bit1.2 booleanCW
61<VH> Presence for Guest (Type1)Presence for Guest (Type1)1 Bit1.2 booleanCRT
62<Logic 3> Input BLogic1 Bit1.2 booleanCW
62<Logic 3> Input B 4Byte CountInput B 4Byte Count4 Bytes12.1 counter pulses (unsigned)CW
62<Logic 3> Input B 4Byte UCountInput B 4Byte UCount4 Bytes14.56 power (W)CW
62<Logic 3> Input B 4Byte FloatInput B 4Byte Float4 Bytes13.1 counter pulses (signed)CW
62<Logic 3> Input B 2Byte CountInput B 2Byte Count2 Bytes8.1 pulses differenceCW
62<Logic 3> Input B 2Byte UCountInput B 2Byte UCount2 Bytes7.1 pulsesCW
62<Logic 3> Input B 2Byte FloatInput B 2Byte Float2 Bytes9.1 temperature (°C)CW
62<Logic 3> Input B CountInput B Count1 Byte6.10 counter pulses (-128..127)CW
62<Logic 3> Input B UCountInput B UCount1 Byte5.10 counter pulses (0..255)CW
62<Logic 3> Input B BitInput B Bit1 Bit1.2 booleanCW
62<VH> Signal Guest (Type1)Signal Guest (Type1)1 Bit1.2 booleanCW
63<Logic 3> Input C 4Byte CountInput C 4Byte Count4 Bytes12.1 counter pulses (unsigned)CW
63<Logic 3> Input C 4Byte UCountInput C 4Byte UCount4 Bytes14.56 power (W)CW
63<Logic 3> Input C 4Byte FloatInput C 4Byte Float4 Bytes13.1 counter pulses (signed)CW
63<Logic 3> Input C 2Byte CountInput C 2Byte Count2 Bytes8.1 pulses differenceCW
63<Logic 3> Input C 2Byte UCountInput C 2Byte UCount2 Bytes7.1 pulsesCW
63<Logic 3> Input C 2Byte FloatInput C 2Byte Float2 Bytes9.1 temperature (°C)CW
63<Logic 3> Input C CountInput C Count1 Byte6.10 counter pulses (-128..127)CW
63<Logic 3> Input C UCountInput C UCount1 Byte5.10 counter pulses (0..255)CW
63<Logic 3> Input C BitInput C Bit1 Bit1.2 booleanCW
63<VH> Presence for Service (Type2)Presence for Service (Type2)1 Bit1.2 booleanCRT
64<Logic 3> Input D 4Byte CountInput D 4Byte Count4 Bytes12.1 counter pulses (unsigned)CW
64<Logic 3> Input D 4Byte UCountInput D 4Byte UCount4 Bytes14.56 power (W)CW
64<Logic 3> Input D 4Byte FloatInput D 4Byte Float4 Bytes13.1 counter pulses (signed)CW
64<Logic 3> Input D 2Byte CountInput D 2Byte Count2 Bytes8.1 pulses differenceCW
64<Logic 3> Input D 2Byte UCountInput D 2Byte UCount2 Bytes7.1 pulsesCW
64<Logic 3> Input D 2Byte FloatInput D 2Byte Float2 Bytes9.1 temperature (°C)CW
64<Logic 3> Input D CountInput D Count1 Byte6.10 counter pulses (-128..127)CW
64<Logic 3> Input D UCountInput D UCount1 Byte5.10 counter pulses (0..255)CW
64<Logic 3> Input D BitInput D Bit1 Bit1.2 booleanCW
64<VH> Signal Service (Type2)Signal Service (Type2)1 Bit1.2 booleanCW
65<Logic 4> OutputLogic1 Bit1.2 booleanCRT
65<Logic 4> Output1 Byte1 Byte5.10 counter pulses (0..255)CRT
65<Logic 4> Output1 Bit1 Bit1.2 booleanCRT
65<Logic 4> Output 4Byte CountOutput 4Byte Count4 Bytes13.1 counter pulses (signed)CRT
65<Logic 4> Output 4Byte UCountOutput 4Byte UCount4 Bytes12.1 counter pulses (unsigned)CRT
65<Logic 4> Output 4Byte FloatOutput 4Byte Float4 Bytes14.56 power (W)CRT
65<Logic 4> Output 2Byte CountOutput 2Byte Count2 Bytes8.1 pulses differenceCRT
65<Logic 4> Output 2Byte UCountOutput 2Byte UCount2 Bytes7.1 pulsesCRT
65<Logic 4> Output 2Byte FloatOutput 2Byte Float2 Bytes9.1 temperature (°C)CRT
65<Logic 4> Output CountOutput Count1 Byte6.10 counter pulses (-128..127)CRT
65<Logic 4> Output UCountOutput UCount1 Byte5.10 counter pulses (0..255)CRT
65<Logic 4> Output BitOutput Bit1 Bit1.2 booleanCRT
65<VH> Presence for Maintenance (Type3)Presence Maintenance (Type3)1 Bit1.2 booleanCRT
66<Logic 4> InputLogic1 Bit1.2 booleanCW
66<Logic 4> Input1 Byte1 Byte5.10 counter pulses (0..255)CW
66<Logic 4> Input ALogic1 Bit1.2 booleanCW
66<Logic 4> Input1 Bit1 Bit1.2 booleanCW
66<Logic 4> Input2 Bytes2 Bytes9.1 temperature (°C)CW
66<Logic 4> Input4 Bytes4 Bytes14.56 power (W)CW
66<Logic 4> Input A 4Byte CountInput A 4Byte Count4 Bytes13.1 counter pulses (signed)CW
66<Logic 4> Input A 4Byte UCountInput A 4Byte UCount4 Bytes12.1 counter pulses (unsigned)CW
66<Logic 4> Input A 4Byte FloatInput A 4Byte Float4 Bytes14.56 power (W)CW
66<Logic 4> Input A 2Byte CountInput A 2Byte Count2 Bytes8.1 pulses differenceCW
66<Logic 4> Input A 2Byte UCountInput A 2Byte UCount2 Bytes7.1 pulsesCW
66<Logic 4> Input A 2Byte FloatInput A 2Byte Float2 Bytes9.1 temperature (°C)CW
66<Logic 4> Input A CountInput A Count1 Byte6.10 counter pulses (-128..127)CW
66<Logic 4> Input A UCountInput A UCount1 Byte5.10 counter pulses (0..255)CW
66<Logic 4> Input A BitInput A Bit1 Bit1.2 booleanCW
66<VH> Signal Maintenance (Type3)Signal Maintenance (Type3)1 Bit1.2 booleanCW
67<Logic 4> Input BLogic1 Bit1.2 booleanCW
67<Logic 4> Input B 4Byte CountInput B 4Byte Count4 Bytes12.1 counter pulses (unsigned)CW
67<Logic 4> Input B 4Byte UCountInput B 4Byte UCount4 Bytes14.56 power (W)CW
67<Logic 4> Input B 4Byte FloatInput B 4Byte Float4 BytesDPT.14CW
67<Logic 4> Input B 2Byte CountInput B 2Byte Count2 Bytes8.1 pulses differenceCW
67<Logic 4> Input B 2Byte UCountInput B 2Byte UCount2 Bytes7.1 pulsesCW
67<Logic 4> Input B 2Byte FloatInput B 2Byte Float2 Bytes9.1 temperature (°C)CW
67<Logic 4> Input B CountInput B Count1 Byte6.10 counter pulses (-128..127)CW
67<Logic 4> Input B UCountInput B UCount1 Byte5.10 counter pulses (0..255)CW
67<Logic 4> Input B BitInput B Bit1 Bit1.2 booleanCW
67<VH> Remote Input 1 DoorRemote Input 1 Door1 Bit1.2 booleanCW
67<VH> Remote Input 1 PresenceRemote Input 1 Presence1 Bit1.2 booleanCW
67<VH> Remote Input 1 SnifferRemote Input 1 Sniffer1 Bit1.2 booleanCW
68<Logic 4> Input C 4Byte CountInput C 4Byte Count4 Bytes12.1 counter pulses (unsigned)CW
68<Logic 4> Input C 4Byte UCountInput C 4Byte UCount4 Bytes14.56 power (W)CW
68<Logic 4> Input C 4Byte FloatInput C 4Byte Float4 BytesDPT.14CW
68<Logic 4> Input C 2Byte CountInput C 2Byte Count2 Bytes8.1 pulses differenceCW
68<Logic 4> Input C 2Byte UCountInput C 2Byte UCount2 Bytes7.1 pulsesCW
68<Logic 4> Input C 2Byte FloatInput C 2Byte Float2 Bytes9.1 temperature (°C)CW
68<Logic 4> Input C CountInput C Count1 Byte6.10 counter pulses (-128..127)CW
68<Logic 4> Input C UCountInput C UCount1 Byte5.10 counter pulses (0..255)CW
68<Logic 4> Input C BitInput C Bit1 Bit1.2 booleanCW
68<VH> Remote Input 2 DoorRemote Input 2 Door1 Bit1.2 booleanCW
68<VH> Remote Input 2 PresenceRemote Input 2 Presence1 Bit1.2 booleanCW
68<VH> Remote Input 2 SnifferRemote Input 2 Sniffer1 Bit1.2 booleanCW
69<Logic 4> Input D 4Byte CountInput D 4Byte Count4 Bytes12.1 counter pulses (unsigned)CW
69<Logic 4> Input D 4Byte FloatInput D 4Byte Float4 BytesDPT.14CW
69<Logic 4> Input D 4Byte UCountInput D 4Byte UCount4 Bytes14.56 power (W)CW
69<Logic 4> Input D 2Byte CountInput D 2Byte Count2 Bytes8.1 pulses differenceCW
69<Logic 4> Input D 2Byte UCountInput D 2Byte UCount2 Bytes7.1 pulsesCW
69<Logic 4> Input D 2Byte FloatInput D 2Byte Float2 Bytes9.1 temperature (°C)CW
69<Logic 4> Input D CountInput D Count1 Byte6.10 counter pulses (-128..127)CW
69<Logic 4> Input D UCountInput D UCount1 Byte5.10 counter pulses (0..255)CW
69<Logic 4> Input D BitInput D Bit1 Bit1.2 booleanCW
69<VH> Remote Input 3 DoorRemote Input 3 Door1 Bit1.2 booleanCW
69<VH> Remote Input 3 PresenceRemote Input 3 Presence1 Bit1.2 booleanCW
69<VH> Remote Input 3 SnifferRemote Input 3 Sniffer1 Bit1.2 booleanCW
70<Logic 5> OutputLogic1 Bit1.2 booleanCRT
70<Logic 5> Output1 Byte1 Byte5.10 counter pulses (0..255)CRT
70<Logic 5> Output1 Bit1 Bit1.2 booleanCRT
70<Logic 5> Output 4Byte CountOutput 4Byte Count4 Bytes13.1 counter pulses (signed)CRT
70<Logic 5> Output 4Byte UCountOutput 4Byte UCount4 Bytes12.1 counter pulses (unsigned)CRT
70<Logic 5> Output 4Byte FloatOutput 4Byte Float4 Bytes14.56 power (W)CRT
70<Logic 5> Output 2Byte CountOutput 2Byte Count2 Bytes8.1 pulses differenceCRT
70<Logic 5> Output 2Byte UCountOutput 2Byte UCount2 Bytes7.1 pulsesCRT
70<Logic 5> Output 2Byte FloatOutput 2Byte Float2 Bytes9.1 temperature (°C)CRT
70<Logic 5> Output CountOutput Count1 Byte6.10 counter pulses (-128..127)CRT
70<Logic 5> Output UCountOutput UCount1 Byte5.10 counter pulses (0..255)CRT
70<Logic 5> Output BitOutput Bit1 Bit1.2 booleanCRT
70<VH> Remote Input 4 DoorRemote Input 4 Door1 Bit1.2 booleanCW
70<VH> Remote Input 4 PresenceRemote Input 4 Presence1 Bit1.2 booleanCW
70<VH> Remote Input 4 SnifferRemote Input 4 Sniffer1 Bit1.2 booleanCW
71<Logic 5> InputLogic1 Bit1.2 booleanCW
71<Logic 5> Input1 Byte1 Byte5.10 counter pulses (0..255)CW
71<Logic 5> Input ALogic1 Bit1.2 booleanCW
71<Logic 5> Input1 Bit1 Bit1.2 booleanCW
71<Logic 5> Input2 Bytes2 Bytes9.1 temperature (°C)CW
71<Logic 5> Input4 Bytes4 BytesDPT.14CW
71<Logic 5> Input A 4Byte CountInput A 4Byte Count4 Bytes13.1 counter pulses (signed)CW
71<Logic 5> Input A 4Byte UCountInput A 4Byte UCount4 Bytes12.1 counter pulses (unsigned)CW
71<Logic 5> Input A 4Byte FloatInput A 4Byte Float4 Bytes14.56 power (W)CW
71<Logic 5> Input A 2Byte CountInput A 2Byte Count2 Bytes8.1 pulses differenceCW
71<Logic 5> Input A 2Byte UCountInput A 2Byte UCount2 Bytes7.1 pulsesCW
71<Logic 5> Input A 2Byte FloatInput A 2Byte Float2 Bytes9.1 temperature (°C)CW
71<Logic 5> Input A CountInput A Count1 Byte6.10 counter pulses (-128..127)CW
71<Logic 5> Input A UCountInput A UCount1 Byte5.10 counter pulses (0..255)CW
71<Logic 5> Input A BitInput A Bit1 Bit1.2 booleanCW
71<VH> Remote Input 5 DoorRemote Input 5 Door1 Bit1.2 booleanCW
71<VH> Remote Input 5 PresenceRemote Input 5 Presence1 Bit1.2 booleanCW
71<VH> Remote Input 5 SnifferRemote Input 5 Sniffer1 Bit1.2 booleanCW
72<Logic 5> Input BLogic1 Bit1.2 booleanCW
72<Logic 5> Input B 4Byte CountInput B 4Byte Count4 Bytes12.1 counter pulses (unsigned)CW
72<Logic 5> Input B 4Byte UCountInput B 4Byte UCount4 Bytes14.56 power (W)CW
72<Logic 5> Input B 4Byte FloatInput B 4Byte Float4 BytesDPT.14CW
72<Logic 5> Input B 2Byte CountInput B 2Byte Count2 Bytes8.1 pulses differenceCW
72<Logic 5> Input B 2Byte UCountInput B 2Byte UCount2 Bytes7.1 pulsesCW
72<Logic 5> Input B 2Byte FloatInput B 2Byte Float2 Bytes9.1 temperature (°C)CW
72<Logic 5> Input B CountInput B Count1 Byte6.10 counter pulses (-128..127)CW
72<Logic 5> Input B UCountInput B UCount1 Byte5.10 counter pulses (0..255)CW
72<Logic 5> Input B BitInput B Bit1 Bit1.2 booleanCW
73<Logic 5> Input C 4Byte CountInput C 4Byte Count4 Bytes12.1 counter pulses (unsigned)CW
73<Logic 5> Input C 4Byte UCountInput C 4Byte UCount4 Bytes14.56 power (W)CW
73<Logic 5> Input C 4Byte FloatInput C 4Byte Float4 BytesDPT.14CW
73<Logic 5> Input C 2Byte CountInput C 2Byte Count2 Bytes8.1 pulses differenceCW
73<Logic 5> Input C 2Byte UCountInput C 2Byte UCount2 Bytes7.1 pulsesCW
73<Logic 5> Input C 2Byte FloatInput C 2Byte Float2 Bytes9.1 temperature (°C)CW
73<Logic 5> Input C CountInput C Count1 Byte6.10 counter pulses (-128..127)CW
73<Logic 5> Input C UCountInput C UCount1 Byte5.10 counter pulses (0..255)CW
73<Logic 5> Input C BitInput C Bit1 Bit1.2 booleanCW
74<Logic 5> Input D 4Byte CountInput D 4Byte Count4 Bytes12.1 counter pulses (unsigned)CW
74<Logic 5> Input D 4Byte UCountInput D 4Byte UCount4 Bytes14.56 power (W)CW
74<Logic 5> Input D 4Byte FloatInput D 4Byte Float4 BytesDPT.14CW
74<Logic 5> Input D 2Byte CountInput D 2Byte Count2 Bytes8.1 pulses differenceCW
74<Logic 5> Input D 2Byte UCountInput D 2Byte UCount2 Bytes7.1 pulsesCW
74<Logic 5> Input D 2Byte FloatInput D 2Byte Float2 Bytes9.1 temperature (°C)CW
74<Logic 5> Input D CountInput D Count1 Byte6.10 counter pulses (-128..127)CW
74<Logic 5> Input D UCountInput D UCount1 Byte5.10 counter pulses (0..255)CW
74<Logic 5> Input D BitInput D Bit1 Bit1.2 booleanCW
Parameters (263)
ParameterTypeDefault
Functionlistnothing
Telegram associatedlist1 bit
Command associated with presslistoff
Feedback objectlistdisabled
Cyclic sending when button pressedlistnever
Command associated with presslistvalue 0-255
Value associated with pressunsignedInt 0…2550
Value associated with presslist0%
Value associated with presslistauto
Command associated with presslistnothing
Command associated with releaselistnothing
Communication object on releaselistdisabled
Command typelistvalue 0-255
Value associated with releaseunsignedInt 0…2550
Value associated with releaselist0%
Value associated with releaselistauto
Command associated with short presslistnothing
Command associated with long presslistnothing
Communication object on long presslistdisabled
Value associated with short pressunsignedInt 0…2550
Value associated with long pressunsignedInt 0…2550
Value associated with short presslist0%
Value associated with long presslist0%
Value associated with short presslistauto
Value associated with long presslistauto
Dimming modelistbrighter
Dimming steplistmaximum brightness
Dimming steplistminimum brightness
Dimming steplistmaximum/minimum brightness
Command drive shutterlistmove up
Scene number (0-63)unsignedInt 0…630
Store scene on long presslistdisabled
Enable learn scene objectlistdisabled
Telegram associated with command Alist1 bit
Telegram associated with command Blist1 bit
Telegram associated with command Clist1 bit
Command typelistnothing
Command associated with operation 1listnothing
Command associated with operation 2listnothing
Value associated with operation 1unsignedInt 0…2550
Value associated with operation 2unsignedInt 0…2550
Value associated with operation 1list0%
Value associated with operation 2list0%
Value associated with operation 1listauto
Value associated with operation 2listauto
Minimum time long press button UPlist0.3 s
Minimum time long press button RIGHTlist0.3 s
Minimum time long press button DOWNlist0.3 s
Minimum time long press button LEFTlist0.3 s
Delay between commandsunsignedInt 0…2550
Delay to send telegrams on power up [s]unsignedInt 5…155
Temperature functionlistdisabled
RTC functionlisttemperature sensor
Button configurationlistall independent
Temperature sourcelistwired probe
External sensor calibration [0.1°C]signedInt -100…1000
KNX sensor calibration [0.1°C]signedInt -100…1000
Temperature objectlistdisabled
Sending intervallistnever
Sending on variationlistnever
Enable threshold T1 (low)listdisabled
Enable threshold T2 (high)listdisabled
Object enable/disable for trigger 1 and 2listhide
Initial value for object enable(1)/disable(0)list0
Threshold T1signedInt -15…900
Threshold T2signedInt -15…900
Sensor codelistTS01A01ACC
Telegram to send when T < T1listtelegram "1"
Telegram to send when T > T2listtelegram "1"
Threshold T1signedInt -40…550
Threshold T2signedInt -40…550
Threshold T1signedInt -40…900
Threshold T2signedInt -40…900
Use thermostat to control fan coilslistno
Fan coil typelistfan coil control on / off
Thermostat control modelistHVAC mode (switched heat/cool)
Value of Heat/Cool object after downloadlist1 = heating
Value of HVAC mode object after downloadlistoff (frost / high temperature protection)
Control type when comfort endsliststandby
Comfort object prioritylistno
Comfort objectlisttime unlimited
Comfort overwrite time [min]unsignedInt 1…2551
Enable 1 bit comfort objectlistdisabled
Window contactlistdisabled
Thermostat OFF objectlistdisabled
Window contact activation telegramlisttelegram "1"
Setpoint adjustment value formatlist2 bytes object - temperature value
Adjustment allowedlist-/+ 3°C
Keep setpoint adjustment value on power uplistenabled
Increase setpoint adjustment withlisttelegram "0"
Enable setpoint adjustment objectlistdisabled
Weight wired probelist10%
Control algorithmlist2 points on/off control
Time period for on/off cyclic sendinglistno cyclic sending
Regulation differential value - heatinglist0.2°C
Regulation differential value - coolinglist0.2°C
Proportional band [Bp]list2°C
Cycle timelist10 min
Integration time [min] [Ti]unsignedInt 5…250120
Integration time [min] [Ti]unsignedInt 5…2505
Enable fancoil speeds onlistheating / cooling
System typelist2 pipes
Speed numberlist1 speed
Regulation differential value S1-heatinglist0.2°C
Regulation differential value S1-coolinglist0.2°C
Regulation differential value S2-heatinglist0.2°C
Regulation differential value S2-coolinglist0.2°C
Initial value MAN (0) / AUTO (1) objectlist1
Setpoint frost protectionlist7°C
Setpoint economy heating (Teh)list16°C
Setpoint standby heating (Tsh)list18°C
Setpoint comfort heating (Tch)list20°C
Setpoint high temperature protectionlist35°C
Setpoint economy cooling (Tec)list28°C
Setpoint standby cooling (Tsc)list26°C
Setpoint comfort cooling (Tcc)list24°C
Dead bandlist2°C
Minimum time long press INPUTlist0.3 s
Enable 2nd stage controllistdisabled
2nd Stage Heatinglistdisabled
2nd Stage Coolinglistdisabled
Bandgap [0.1°C*10]unsignedInt 0…25580
ComfortunsignedInt 0…10
StandbyunsignedInt 0…10
EconomyunsignedInt 0…10
Building protectionunsignedInt 0…10
Work over:listventilation
Activation telegram 2nd stage heatinglisttelegram "1"
Activation telegram 2nd stage coolinglisttelegram "1"
Led ON behaviourlistfixed
Activation telegramlisttelegram "1"
Initial state led RGBlistoff
LED ON time [0=while pressed / 1..20=1..20 s]unsignedInt 0…200
Color RGB Ledlistwhite
Object ON/OFFlistenabled
Communication object typelistboth
Telegram activation for night modelisttelegram "1"
Number of KNX feedbacklist2
Activation telegram KNX feedback 1listtelegram "0"
Activation telegram KNX feedback 2listtelegram "0"
Activation telegram KNX feedback 3listtelegram "0"
Activation telegram KNX feedback 4listtelegram "0"
Activation telegram KNX feedback 5listtelegram "0"
Color KNX feedback 1listwhite
Color KNX feedback 2listwhite
Color KNX feedback 3listwhite
Color KNX feedback 4listwhite
Color KNX feedback 5listwhite
Physical dimension sizelist1 byte unsigned
Default colorlistred [0]
Color at minimum valuelistred [0]
Color at maximum valuelistred-magenta [11]
Color directionlistCW
Min physical valuesignedInt -2147483648…2147483647-2147483648
Min physical valueunsignedInt 0…42949672950
Min physical valuefloat -9223372036854776000…87622034350120370000
Min physical valuesignedInt -32768…32767-32768
Min physical valueunsignedInt 0…655350
Min physical valuefloat -671088…670760-671088
Min physical valuesignedInt -128…127-128
Min physical valueunsignedInt 0…2550
Max physical valuesignedInt -32768…3276732767
Max physical valueunsignedInt 0…6553565535
Max physical valuefloat -671088…670760670760
Max physical valueunsignedInt 0…255255
Max physical valuesignedInt -128…127127
Max physical valuesignedInt -2147483648…21474836472147483647
Max physical valueunsignedInt 0…42949672954294967295
Max physical valuefloat -9223372036854776000…87622034350120370001280
Led color associated to physical valuepicture
Thermostat show typelistHVAC
Use same colors between heat and coolunsignedInt 0…10
Min. temperature heat [°C]unsignedInt 0…6318
Max. temperature heat [°C]unsignedInt 0…6324
Min. temperature cool [°C]unsignedInt 0…6322
Max. temperature cool [°C]unsignedInt 0…6326
Time of color changeunsignedInt 3…2553
Colors LEDlistall colors of wheel
RGB main functionlistnothing
RGB temporary functionlistnothing
Brightness limit nightlist50%
Brightness limit daylist100%
Initial colortext#FFFFFF
Standard physical dimensionlist0-100%
Physical dimensionlistphysical dimension size
Min physical valuelist0%
Max physical valuelist100%
Brightness limitlistnone
Initial brightnesslist100%
RGB step light modelistdisabled
Step light colorlistred
Blinklistblink 1 s
Stop actionlistswitch off led
Color stoplistred
Out scale min behaviourlistblink 1 s
Out scale max behaviourlistblink 1 s
Stop telegramlisttelegram "0"
Initial color settinglistcolor list
Initial colorlistwhite
Set valuelistred
Long press to change colorlistlong press disabled
Enable sending colors during transitionslistdisabled
Logic functionlistdisabled
Logic delaylist0
Number of transmissions on outputlist1
Retransmission delaylist2 s
Value sent when 0 is receivedunsignedInt 0…2550
Value sent when 1 is receivedunsignedInt 0…255128
Byte valueunsignedInt 0…255128
Output bit when byte is receivedlist1
Output bit otherwiselist0
Threshold valueunsignedInt 0…255128
Output bit when input > thresholdlist1
Output bit when input <= thresholdlist0
Threshold valuefloat -671088…6707600
Threshold valuefloat -9223372036854776000…87622034350120370000
DPT Outputlist1 bit
DPT Input Alist1 bit
DPT Input Blist1 bit
DPT Input Clist1 bit
DPT Input Dlist1 bit
Logic expressiontext0
Virtual holder2listdisabled
Virtual holder3listdisabled
Virtual holder4listdisabled
Virtual holder5listdisabled
Virtual holderlistdisabled
Presence Wait Timelist15 min
Cyclic Presence Send Timelistno cyclic send
Presence sensor OFF latency [s]unsignedInt 0…6310
Absence with door open (deny=if door open presence is active)listallow
Remote input type 1listdisabled
Remote input 1 subordinate to 'Global Enable'listnot subordinate
Remote input type 2listdisabled
Remote input 2 subordinate to 'Global Enable'listnot subordinate
Remote input type 3listdisabled
Remote input 3 subordinate to 'Global Enable'listnot subordinate
Remote input type 4listdisabled
Remote input 4 subordinate to 'Global Enable'listnot subordinate
Remote input type 5listdisabled
Remote input 5 subordinate to 'Global Enable'listnot subordinate
HVAC booked goodbyelistdo not send
HVAC non-booked goodbyelistdo not send
HVAC booked welcomelistdo not send
HVAC non-booked welcomelistdo not send
Send additional booked goodbyelistdo not send
Value additional booked goodbyeunsignedInt 0…2550
Send additional non-booked goodbyelistdo not send
Value additional non-booked goodbyeunsignedInt 0…2550
Send additional booked welcomelistdo not send
Value additional booked welcomeunsignedInt 0…2550
Send additional non-booked welcomelistdo not send
Value additional non-booked welcomeunsignedInt 0…2550
Global Enable state after downloadlistdisabled
Send welcome on unexpected presencelistdo not send
Booked state after downloadlistnot booked
Enable additional valvelistdisabled
Enable valve whenlistcooling
Control algorithmlistintegral proportional control PWM
Cyclic timelist10 min
Surveillance time for KNX probe (0=disabled) [min]unsignedInt 0…25515
Reset SP adjustment on HVAC economylistno reset
Reset SP adjustment on HEAT/COOL changelistno reset

Version history

ApplicationApp noFingerprintFirst seenSizeFile
SB40AxxKNX 1.2 latest$0080386E2026-11-25548 KBDownload

About this file

This is the official ETS product database for the Eelectron 3025 4 CH - SB40A (SB40A10KNX), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.

More from Eelectron

All Eelectron products