Download .knxprod SGPxx Switch 3.0 · 686 KB

Product

ManufacturerEAE
Product nameSGPxx Mona Switch
Order number48174
Product textSGPxx Switch
HardwareSwitch
MediumTwisted Pair
Bus current (mA)25
Rail mountedNo
RegistrationCertified · 2020-09-08
Languagesde-DE, es-ES, fr-FR, it-IT, en-US
Catalog entryM-011E_H-48174-1_HP-BC2E-30-18C2_CI-48174-1
Fingerprint18C2
SHA-2569aa3043e0057c3f27be5e8c4b3e49dc684d09983b3910d7f7df48bb8e10464b7
First seen2026-11-25
Markets69 markets

Application program: SGPxx Switch 3.0

Application number$BC2E
Version3.0
Mask versionMV-0705 (7.5)
KNX Data SecureNo
Minimum ETS version5.0
Parameters2552
Group objects6254
Group objects (6254)
NoNameFunctionSizeDPTFlags
0In Operation[0,1]1 Bit1.17 triggerCT
0Button 1 {{0:}}Switching <-> On/Off & Status1 Bit1.1 switchCWT
0Button 1 [Short Press]Dimming <-> On/Off & Status1 Bit1.1 switchCWT
0Button 1 {{0:}}Shutter <-> Up/Down1 Bit1.8 up/downCWT
0Button 1 [Short Press]Dimming --> On/Off1 Bit1.1 switchCT
0Button 1 {{0:}}Switching --> On/Off1 Bit1.1 switchCT
0Button 2 {{0:}}Switching <-> On/Off & Status1 Bit1.1 switchCWT
0Button 2 [Short Press]Dimming <-> On/Off & Status1 Bit1.1 switchCWT
0Button 2 {{0:}}Shutter <-> Up/Down1 Bit1.8 up/downCWT
0Button 2 [Short Press]Dimming --> On/Off1 Bit1.1 switchCT
0Button 2 {{0:}}Switching --> On/Off1 Bit1.1 switchCT
0Button 3 {{0:}}Switching <-> On/Off & Status1 Bit1.1 switchCWT
0Button 3 [Short Press]Dimming <-> On/Off & Status1 Bit1.1 switchCWT
0Button 3 {{0:}}Shutter <-> Up/Down1 Bit1.8 up/downCWT
0Button 3 [Short Press]Dimming --> On/Off1 Bit1.1 switchCT
0Button 3 {{0:}}Switching --> On/Off1 Bit1.1 switchCT
0Button 4 {{0:}}Switching <-> On/Off & Status1 Bit1.1 switchCWT
0Button 4 [Short Press]Dimming <-> On/Off & Status1 Bit1.1 switchCWT
0Button 4 {{0:}}Shutter <-> Up/Down1 Bit1.8 up/downCWT
0Button 4 [Short Press]Dimming --> On/Off1 Bit1.1 switchCT
0Button 4 {{0:}}Switching --> On/Off1 Bit1.1 switchCT
0Button 5 {{0:}}Switching <-> On/Off & Status1 Bit1.1 switchCWT
0Button 5 [Short Press]Dimming <-> On/Off & Status1 Bit1.1 switchCWT
0Button 5 {{0:}}Shutter <-> Up/Down1 Bit1.8 up/downCWT
0Button 5 [Short Press]Dimming --> On/Off1 Bit1.1 switchCT
0Button 5 {{0:}}Switching --> On/Off1 Bit1.1 switchCT
0Button 6 {{0:}}Switching <-> On/Off & Status1 Bit1.1 switchCWT
0Button 6 [Short Press]Dimming <-> On/Off & Status1 Bit1.1 switchCWT
0Button 6 {{0:}}Shutter <-> Up/Down1 Bit1.8 up/downCWT
0Button 6 [Short Press]Dimming --> On/Off1 Bit1.1 switchCT
0Button 6 {{0:}}Switching --> On/Off1 Bit1.1 switchCT
0Button 7 {{0:}}Switching <-> On/Off & Status1 Bit1.1 switchCWT
0Button 7 [Short Press]Dimming <-> On/Off & Status1 Bit1.1 switchCWT
0Button 7 {{0:}}Shutter <-> Up/Down1 Bit1.8 up/downCWT
0Button 7 [Short Press]Dimming --> On/Off1 Bit1.1 switchCT
0Button 7 {{0:}}Switching --> On/Off1 Bit1.1 switchCT
0Button 8 {{0:}}Switching <-> On/Off & Status1 Bit1.1 switchCWT
0Button 8 [Short Press]Dimming <-> On/Off & Status1 Bit1.1 switchCWT
0Button 8 {{0:}}Shutter <-> Up/Down1 Bit1.8 up/downCWT
0Button 8 [Short Press]Dimming --> On/Off1 Bit1.1 switchCT
0Button 8 {{0:}}Switching --> On/Off1 Bit1.1 switchCT
0Button 9 {{0:}}Switching <-> On/Off & Status1 Bit1.1 switchCWT
0Button 9 [Short Press]Dimming <-> On/Off & Status1 Bit1.1 switchCWT
0Button 9 {{0:}}Shutter <-> Up/Down1 Bit1.8 up/downCWT
0Button 9 [Short Press]Dimming --> On/Off1 Bit1.1 switchCT
0Button 9 {{0:}}Switching --> On/Off1 Bit1.1 switchCT
0Button 10 {{0:}}Switching <-> On/Off & Status1 Bit1.1 switchCWT
0Button 10 [Short Press]Dimming <-> On/Off & Status1 Bit1.1 switchCWT
0Button 10 {{0:}}Shutter <-> Up/Down1 Bit1.8 up/downCWT
0Button 10 [Short Press]Dimming --> On/Off1 Bit1.1 switchCT
0Button 10 {{0:}}Switching --> On/Off1 Bit1.1 switchCT
0Button 11 {{0:}}Switching <-> On/Off & Status1 Bit1.1 switchCWT
0Button 11 [Short Press]Dimming <-> On/Off & Status1 Bit1.1 switchCWT
0Button 11 {{0:}}Shutter <-> Up/Down1 Bit1.8 up/downCWT
0Button 11 [Short Press]Dimming --> On/Off1 Bit1.1 switchCT
0Button 11 {{0:}}Switching --> On/Off1 Bit1.1 switchCT
0Button 12 {{0:}}Switching <-> On/Off & Status1 Bit1.1 switchCWT
0Button 12 [Short Press]Dimming <-> On/Off & Status1 Bit1.1 switchCWT
0Button 12 {{0:}}Shutter <-> Up/Down1 Bit1.8 up/downCWT
0Button 12 [Short Press]Dimming --> On/Off1 Bit1.1 switchCT
0Button 12 {{0:}}Switching --> On/Off1 Bit1.1 switchCT
0Button 1 [Short Press 1]Value --> 1-bit1 Bit1.1 switchCT
0Button 1 [Short Press 1]Value --> 1-bit HVAC control mode1 Bit1.100 cooling/heatingCT
0Button 1 [Short Press 1]Value <-> 1-bit toggle1 Bit1.1 switchCWT
0Button 1 [Short Press 1]Value --> 1-byte unsigned1 Byte5.10 counter pulses (0..255)CT
0Button 1 [Short Press 1]Value --> 1-byte signed1 Byte6.10 counter pulses (-128..127)CT
0Button 1 [Short Press 1]Value --> 1-byte HVAC operating mode1 Byte20.102 HVAC modeCT
0Button 1 [Short Press 1]Value --> 1-byte percentage1 Byte5.1 percentage (0..100%)CT
0Button 1 [Short Press 1]Value --> 1-byte scene activate1 Byte18.1 scene controlCT
0Button 1 [Short Press 1]Value --> 2-byte unsigned2 Bytes7.1 pulsesCT
0Button 1 [Short Press 1]Value --> 2-byte signed2 Bytes8.1 pulses differenceCT
0Button 1 [Short Press 1]Value --> 2-byte float2 Bytes9.1 temperature (°C)CT
0Button 1 [Short Press 1]Value --> 4-byte unsigned4 Bytes12.1 counter pulses (unsigned)CT
0Button 1 [Short Press 1]Value --> 4-byte signed4 Bytes13.1 counter pulses (signed)CT
0Button 1 [Short Press 1]Value --> 4-byte float4 Bytes14.5 amplitudeCT
0Button 1 [Short Press 1]Value <-> 1-byte counter/sequence1 Byte5.10 counter pulses (0..255)CWT
0Button 1 [Short Press 1]Value --> 2-bit priority control2 Bit2.1 switch controlCT
0Button 1 [Short Press 1]Value --> 4-bit dimming control4 Bit3.7 dimming controlCT
0Button 1 [Short Press 1]Value --> 4-bit blind control4 Bit3.8 blind controlCT
0Button 1 [Short Press 1]Value --> 1-byte scene learn1 Byte18.1 scene controlCT
0Button 1 [Short Press 1]Value --> 3-byte color3 Bytes232.600 RGB value 3x(0..255)CT
0Button 1 [Double Press 1]Value --> 1-bit1 Bit1.1 switchCT
0Button 1 [Double Press 1]Value --> 1-bit HVAC control mode1 Bit1.100 cooling/heatingCT
0Button 1 [Double Press 1]Value <-> 1-bit toggle1 Bit1.1 switchCWT
0Button 1 [Double Press 1]Value --> 1-byte unsigned1 Byte5.10 counter pulses (0..255)CT
0Button 1 [Double Press 1]Value --> 1-byte signed1 Byte6.10 counter pulses (-128..127)CT
0Button 1 [Double Press 1]Value --> 1-byte HVAC operating mode1 Byte20.102 HVAC modeCT
0Button 1 [Double Press 1]Value --> 1-byte percentage1 Byte5.1 percentage (0..100%)CT
0Button 1 [Double Press 1]Value --> 1-byte scene activate1 Byte18.1 scene controlCT
0Button 1 [Double Press 1]Value --> 2-byte unsigned2 Bytes7.1 pulsesCT
0Button 1 [Double Press 1]Value --> 2-byte signed2 Bytes8.1 pulses differenceCT
0Button 1 [Double Press 1]Value --> 2-byte float2 Bytes9.1 temperature (°C)CT
0Button 1 [Double Press 1]Value --> 4-byte unsigned4 Bytes12.1 counter pulses (unsigned)CT
0Button 1 [Double Press 1]Value --> 4-byte signed4 Bytes13.1 counter pulses (signed)CT
0Button 1 [Double Press 1]Value --> 4-byte float4 Bytes14.5 amplitudeCT
0Button 1 [Double Press 1]Value <-> 1-byte counter/sequence1 Byte5.10 counter pulses (0..255)CWT
0Button 1 [Double Press 1]Value --> 2-bit priority control2 Bit2.1 switch controlCT
0Button 1 [Double Press 1]Value --> 4-bit dimming control4 Bit3.7 dimming controlCT
0Button 1 [Double Press 1]Value --> 4-bit blind control4 Bit3.8 blind controlCT
0Button 1 [Double Press 1]Value --> 1-byte scene learn1 Byte18.1 scene controlCT
0Button 1 [Double Press 1]Value --> 3-byte color3 Bytes232.600 RGB value 3x(0..255)CT
0Button 1 [Triple Press 1]Value --> 1-bit1 Bit1.1 switchCT
0Button 1 [Triple Press 1]Value --> 1-bit HVAC control mode1 Bit1.100 cooling/heatingCT
0Button 1 [Triple Press 1]Value <-> 1-bit toggle1 Bit1.1 switchCWT
0Button 1 [Triple Press 1]Value --> 1-byte unsigned1 Byte5.10 counter pulses (0..255)CT
0Button 1 [Triple Press 1]Value --> 1-byte signed1 Byte6.10 counter pulses (-128..127)CT
0Button 1 [Triple Press 1]Value --> 1-byte HVAC operating mode1 Byte20.102 HVAC modeCT
0Button 1 [Triple Press 1]Value --> 1-byte percentage1 Byte5.1 percentage (0..100%)CT
0Button 1 [Triple Press 1]Value --> 1-byte scene activate1 Byte18.1 scene controlCT
0Button 1 [Triple Press 1]Value --> 2-byte unsigned2 Bytes7.1 pulsesCT
0Button 1 [Triple Press 1]Value --> 2-byte signed2 Bytes8.1 pulses differenceCT
0Button 1 [Triple Press 1]Value --> 2-byte float2 Bytes9.1 temperature (°C)CT
0Button 1 [Triple Press 1]Value --> 4-byte unsigned4 Bytes12.1 counter pulses (unsigned)CT
0Button 1 [Triple Press 1]Value --> 4-byte signed4 Bytes13.1 counter pulses (signed)CT
0Button 1 [Triple Press 1]Value --> 4-byte float4 Bytes14.5 amplitudeCT
0Button 1 [Triple Press 1]Value <-> 1-byte counter/sequence1 Byte5.10 counter pulses (0..255)CWT
0Button 1 [Triple Press 1]Value --> 2-bit priority control2 Bit2.1 switch controlCT
0Button 1 [Triple Press 1]Value --> 4-bit dimming control4 Bit3.7 dimming controlCT
0Button 1 [Triple Press 1]Value --> 4-bit blind control4 Bit3.8 blind controlCT
0Button 1 [Triple Press 1]Value --> 1-byte scene learn1 Byte18.1 scene controlCT
0Button 1 [Triple Press 1]Value --> 3-byte color3 Bytes232.600 RGB value 3x(0..255)CT
0Button 1 [Long Press 1]Value --> 1-bit1 Bit1.1 switchCT
0Button 1 [Long Press 1]Value --> 1-bit HVAC control mode1 Bit1.100 cooling/heatingCT
0Button 1 [Long Press 1]Value <-> 1-bit toggle1 Bit1.1 switchCWT
0Button 1 [Long Press 1]Value --> 1-byte unsigned1 Byte5.10 counter pulses (0..255)CT
0Button 1 [Long Press 1]Value --> 1-byte signed1 Byte6.10 counter pulses (-128..127)CT
0Button 1 [Long Press 1]Value --> 1-byte HVAC operating mode1 Byte20.102 HVAC modeCT
0Button 1 [Long Press 1]Value --> 1-byte percentage1 Byte5.1 percentage (0..100%)CT
0Button 1 [Long Press 1]Value --> 1-byte scene activate1 Byte18.1 scene controlCT
0Button 1 [Long Press 1]Value --> 2-byte unsigned2 Bytes7.1 pulsesCT
0Button 1 [Long Press 1]Value --> 2-byte signed2 Bytes8.1 pulses differenceCT
0Button 1 [Long Press 1]Value --> 2-byte float2 Bytes9.1 temperature (°C)CT
0Button 1 [Long Press 1]Value --> 4-byte unsigned4 Bytes12.1 counter pulses (unsigned)CT
0Button 1 [Long Press 1]Value --> 4-byte signed4 Bytes13.1 counter pulses (signed)CT
0Button 1 [Long Press 1]Value --> 4-byte float4 Bytes14.5 amplitudeCT
0Button 1 [Long Press 1]Value <-> 1-byte counter/sequence1 Byte5.10 counter pulses (0..255)CWT
0Button 1 [Long Press 1]Value --> 2-bit priority control2 Bit2.1 switch controlCT
0Button 1 [Long Press 1]Value --> 4-bit dimming control4 Bit3.7 dimming controlCT
0Button 1 [Long Press 1]Value --> 4-bit blind control4 Bit3.8 blind controlCT
0Button 1 [Long Press 1]Value --> 1-byte scene learn1 Byte18.1 scene controlCT
0Button 1 [Long Press 1]Value --> 3-byte color3 Bytes232.600 RGB value 3x(0..255)CT
0Button 1 [Long Press Repeat 1]Value --> 1-bit1 Bit1.1 switchCT
0Button 1 [Long Press Repeat 1]Value --> 1-bit HVAC control mode1 Bit1.100 cooling/heatingCT
0Button 1 [Long Press Repeat 1]Value <-> 1-bit toggle1 Bit1.1 switchCWT
0Button 1 [Long Press Repeat 1]Value --> 1-byte unsigned1 Byte5.10 counter pulses (0..255)CT
0Button 1 [Long Press Repeat 1]Value --> 1-byte signed1 Byte6.10 counter pulses (-128..127)CT
0Button 1 [Long Press Repeat 1]Value --> 1-byte HVAC operating mode1 Byte20.102 HVAC modeCT
0Button 1 [Long Press Repeat 1]Value --> 1-byte percentage1 Byte5.1 percentage (0..100%)CT
0Button 1 [Long Press Repeat 1]Value --> 1-byte scene activate1 Byte18.1 scene controlCT
0Button 1 [Long Press Repeat 1]Value --> 2-byte unsigned2 Bytes7.1 pulsesCT
0Button 1 [Long Press Repeat 1]Value --> 2-byte signed2 Bytes8.1 pulses differenceCT
0Button 1 [Long Press Repeat 1]Value --> 2-byte float2 Bytes9.1 temperature (°C)CT
0Button 1 [Long Press Repeat 1]Value --> 4-byte unsigned4 Bytes12.1 counter pulses (unsigned)CT
0Button 1 [Long Press Repeat 1]Value --> 4-byte signed4 Bytes13.1 counter pulses (signed)CT
0Button 1 [Long Press Repeat 1]Value --> 4-byte float4 Bytes14.5 amplitudeCT
0Button 1 [Long Press Repeat 1]Value <-> 1-byte counter/sequence1 Byte5.10 counter pulses (0..255)CWT
0Button 1 [Long Press Repeat 1]Value --> 2-bit priority control2 Bit2.1 switch controlCT
0Button 1 [Long Press Repeat 1]Value --> 4-bit dimming control4 Bit3.7 dimming controlCT
0Button 1 [Long Press Repeat 1]Value --> 4-bit blind control4 Bit3.8 blind controlCT
0Button 1 [Long Press Repeat 1]Value --> 1-byte scene learn1 Byte18.1 scene controlCT
0Button 1 [Long Press Repeat 1]Value --> 3-byte color3 Bytes232.600 RGB value 3x(0..255)CT
0Button 1 [Long Press Release 1]Value --> 1-bit1 Bit1.1 switchCT
0Button 1 [Long Press Release 1]Value --> 1-bit HVAC control mode1 Bit1.100 cooling/heatingCT
0Button 1 [Long Press Release 1]Value <-> 1-bit toggle1 Bit1.1 switchCWT
0Button 1 [Long Press Release 1]Value --> 1-byte unsigned1 Byte5.10 counter pulses (0..255)CT
0Button 1 [Long Press Release 1]Value --> 1-byte signed1 Byte6.10 counter pulses (-128..127)CT
0Button 1 [Long Press Release 1]Value --> 1-byte HVAC operating mode1 Byte20.102 HVAC modeCT
0Button 1 [Long Press Release 1]Value --> 1-byte percentage1 Byte5.1 percentage (0..100%)CT
0Button 1 [Long Press Release 1]Value --> 1-byte scene activate1 Byte18.1 scene controlCT
0Button 1 [Long Press Release 1]Value --> 2-byte unsigned2 Bytes7.1 pulsesCT
0Button 1 [Long Press Release 1]Value --> 2-byte signed2 Bytes8.1 pulses differenceCT
0Button 1 [Long Press Release 1]Value --> 2-byte float2 Bytes9.1 temperature (°C)CT
0Button 1 [Long Press Release 1]Value --> 4-byte unsigned4 Bytes12.1 counter pulses (unsigned)CT
0Button 1 [Long Press Release 1]Value --> 4-byte signed4 Bytes13.1 counter pulses (signed)CT
0Button 1 [Long Press Release 1]Value --> 4-byte float4 Bytes14.5 amplitudeCT
0Button 1 [Long Press Release 1]Value <-> 1-byte counter/sequence1 Byte5.10 counter pulses (0..255)CWT
0Button 1 [Long Press Release 1]Value --> 2-bit priority control2 Bit2.1 switch controlCT
0Button 1 [Long Press Release 1]Value --> 4-bit dimming control4 Bit3.7 dimming controlCT
0Button 1 [Long Press Release 1]Value --> 4-bit blind control4 Bit3.8 blind controlCT
0Button 1 [Long Press Release 1]Value --> 1-byte scene learn1 Byte18.1 scene controlCT
0Button 1 [Long Press Release 1]Value --> 3-byte color3 Bytes232.600 RGB value 3x(0..255)CT
0Button 1 [Short Press 2]Value --> 1-bit1 Bit1.1 switchCT
0Button 1 [Short Press 2]Value --> 1-bit HVAC control mode1 Bit1.100 cooling/heatingCT
0Button 1 [Short Press 2]Value <-> 1-bit toggle1 Bit1.1 switchCWT
0Button 1 [Short Press 2]Value --> 1-byte unsigned1 Byte5.10 counter pulses (0..255)CT
0Button 1 [Short Press 2]Value --> 1-byte signed1 Byte6.10 counter pulses (-128..127)CT
0Button 1 [Short Press 2]Value --> 1-byte HVAC operating mode1 Byte20.102 HVAC modeCT
0Button 1 [Short Press 2]Value --> 1-byte percentage1 Byte5.1 percentage (0..100%)CT
0Button 1 [Short Press 2]Value --> 1-byte scene activate1 Byte18.1 scene controlCT
0Button 1 [Short Press 2]Value --> 2-byte unsigned2 Bytes7.1 pulsesCT
0Button 1 [Short Press 2]Value --> 2-byte signed2 Bytes8.1 pulses differenceCT
0Button 1 [Short Press 2]Value --> 2-byte float2 Bytes9.1 temperature (°C)CT
0Button 1 [Short Press 2]Value --> 4-byte unsigned4 Bytes12.1 counter pulses (unsigned)CT
0Button 1 [Short Press 2]Value --> 4-byte signed4 Bytes13.1 counter pulses (signed)CT
0Button 1 [Short Press 2]Value --> 4-byte float4 Bytes14.5 amplitudeCT
0Button 1 [Short Press 2]Value <-> 1-byte counter/sequence1 Byte5.10 counter pulses (0..255)CWT
0Button 1 [Short Press 2]Value --> 2-bit priority control2 Bit2.1 switch controlCT
0Button 1 [Short Press 2]Value --> 4-bit dimming control4 Bit3.7 dimming controlCT
0Button 1 [Short Press 2]Value --> 4-bit blind control4 Bit3.8 blind controlCT
0Button 1 [Short Press 2]Value --> 1-byte scene learn1 Byte18.1 scene controlCT
0Button 1 [Short Press 2]Value --> 3-byte color3 Bytes232.600 RGB value 3x(0..255)CT
0Button 1 [Double Press 2]Value --> 1-bit1 Bit1.1 switchCT
0Button 1 [Double Press 2]Value --> 1-bit HVAC control mode1 Bit1.100 cooling/heatingCT
0Button 1 [Double Press 2]Value <-> 1-bit toggle1 Bit1.1 switchCWT
0Button 1 [Double Press 2]Value --> 1-byte unsigned1 Byte5.10 counter pulses (0..255)CT
0Button 1 [Double Press 2]Value --> 1-byte signed1 Byte6.10 counter pulses (-128..127)CT
0Button 1 [Double Press 2]Value --> 1-byte HVAC operating mode1 Byte20.102 HVAC modeCT
0Button 1 [Double Press 2]Value --> 1-byte percentage1 Byte5.1 percentage (0..100%)CT
0Button 1 [Double Press 2]Value --> 1-byte scene activate1 Byte18.1 scene controlCT
0Button 1 [Double Press 2]Value --> 2-byte unsigned2 Bytes7.1 pulsesCT
0Button 1 [Double Press 2]Value --> 2-byte signed2 Bytes8.1 pulses differenceCT
0Button 1 [Double Press 2]Value --> 2-byte float2 Bytes9.1 temperature (°C)CT
0Button 1 [Double Press 2]Value --> 4-byte unsigned4 Bytes12.1 counter pulses (unsigned)CT
0Button 1 [Double Press 2]Value --> 4-byte signed4 Bytes13.1 counter pulses (signed)CT
0Button 1 [Double Press 2]Value --> 4-byte float4 Bytes14.5 amplitudeCT
0Button 1 [Double Press 2]Value <-> 1-byte counter/sequence1 Byte5.10 counter pulses (0..255)CWT
0Button 1 [Double Press 2]Value --> 2-bit priority control2 Bit2.1 switch controlCT
0Button 1 [Double Press 2]Value --> 4-bit dimming control4 Bit3.7 dimming controlCT
0Button 1 [Double Press 2]Value --> 4-bit blind control4 Bit3.8 blind controlCT
0Button 1 [Double Press 2]Value --> 1-byte scene learn1 Byte18.1 scene controlCT
0Button 1 [Double Press 2]Value --> 3-byte color3 Bytes232.600 RGB value 3x(0..255)CT
0Button 1 [Triple Press 2]Value --> 1-bit1 Bit1.1 switchCT
0Button 1 [Triple Press 2]Value --> 1-bit HVAC control mode1 Bit1.100 cooling/heatingCT
0Button 1 [Triple Press 2]Value <-> 1-bit toggle1 Bit1.1 switchCWT
0Button 1 [Triple Press 2]Value --> 1-byte unsigned1 Byte5.10 counter pulses (0..255)CT
0Button 1 [Triple Press 2]Value --> 1-byte signed1 Byte6.10 counter pulses (-128..127)CT
0Button 1 [Triple Press 2]Value --> 1-byte HVAC operating mode1 Byte20.102 HVAC modeCT
0Button 1 [Triple Press 2]Value --> 1-byte percentage1 Byte5.1 percentage (0..100%)CT
0Button 1 [Triple Press 2]Value --> 1-byte scene activate1 Byte18.1 scene controlCT
0Button 1 [Triple Press 2]Value --> 2-byte unsigned2 Bytes7.1 pulsesCT
0Button 1 [Triple Press 2]Value --> 2-byte signed2 Bytes8.1 pulses differenceCT
0Button 1 [Triple Press 2]Value --> 2-byte float2 Bytes9.1 temperature (°C)CT
0Button 1 [Triple Press 2]Value --> 4-byte unsigned4 Bytes12.1 counter pulses (unsigned)CT
0Button 1 [Triple Press 2]Value --> 4-byte signed4 Bytes13.1 counter pulses (signed)CT
0Button 1 [Triple Press 2]Value --> 4-byte float4 Bytes14.5 amplitudeCT
0Button 1 [Triple Press 2]Value <-> 1-byte counter/sequence1 Byte5.10 counter pulses (0..255)CWT
0Button 1 [Triple Press 2]Value --> 2-bit priority control2 Bit2.1 switch controlCT
0Button 1 [Triple Press 2]Value --> 4-bit dimming control4 Bit3.7 dimming controlCT
0Button 1 [Triple Press 2]Value --> 4-bit blind control4 Bit3.8 blind controlCT
0Button 1 [Triple Press 2]Value --> 1-byte scene learn1 Byte18.1 scene controlCT
0Button 1 [Triple Press 2]Value --> 3-byte color3 Bytes232.600 RGB value 3x(0..255)CT
0Button 1 [Long Press 2]Value --> 1-bit1 Bit1.1 switchCT
0Button 1 [Long Press 2]Value --> 1-bit HVAC control mode1 Bit1.100 cooling/heatingCT
0Button 1 [Long Press 2]Value <-> 1-bit toggle1 Bit1.1 switchCWT
0Button 1 [Long Press 2]Value --> 1-byte unsigned1 Byte5.10 counter pulses (0..255)CT
0Button 1 [Long Press 2]Value --> 1-byte signed1 Byte6.10 counter pulses (-128..127)CT
0Button 1 [Long Press 2]Value --> 1-byte HVAC operating mode1 Byte20.102 HVAC modeCT
0Button 1 [Long Press 2]Value --> 1-byte percentage1 Byte5.1 percentage (0..100%)CT
0Button 1 [Long Press 2]Value --> 1-byte scene activate1 Byte18.1 scene controlCT
0Button 1 [Long Press 2]Value --> 2-byte unsigned2 Bytes7.1 pulsesCT
0Button 1 [Long Press 2]Value --> 2-byte signed2 Bytes8.1 pulses differenceCT
0Button 1 [Long Press 2]Value --> 2-byte float2 Bytes9.1 temperature (°C)CT
0Button 1 [Long Press 2]Value --> 4-byte unsigned4 Bytes12.1 counter pulses (unsigned)CT
0Button 1 [Long Press 2]Value --> 4-byte signed4 Bytes13.1 counter pulses (signed)CT
0Button 1 [Long Press 2]Value --> 4-byte float4 Bytes14.5 amplitudeCT
0Button 1 [Long Press 2]Value <-> 1-byte counter/sequence1 Byte5.10 counter pulses (0..255)CWT
0Button 1 [Long Press 2]Value --> 2-bit priority control2 Bit2.1 switch controlCT
0Button 1 [Long Press 2]Value --> 4-bit dimming control4 Bit3.7 dimming controlCT
0Button 1 [Long Press 2]Value --> 4-bit blind control4 Bit3.8 blind controlCT
0Button 1 [Long Press 2]Value --> 1-byte scene learn1 Byte18.1 scene controlCT
0Button 1 [Long Press 2]Value --> 3-byte color3 Bytes232.600 RGB value 3x(0..255)CT
0Button 1 [Long Press Repeat 2]Value --> 1-bit1 Bit1.1 switchCT
0Button 1 [Long Press Repeat 2]Value --> 1-bit HVAC control mode1 Bit1.100 cooling/heatingCT
0Button 1 [Long Press Repeat 2]Value <-> 1-bit toggle1 Bit1.1 switchCWT
0Button 1 [Long Press Repeat 2]Value --> 1-byte unsigned1 Byte5.10 counter pulses (0..255)CT
0Button 1 [Long Press Repeat 2]Value --> 1-byte signed1 Byte6.10 counter pulses (-128..127)CT
0Button 1 [Long Press Repeat 2]Value --> 1-byte HVAC operating mode1 Byte20.102 HVAC modeCT
0Button 1 [Long Press Repeat 2]Value --> 1-byte percentage1 Byte5.1 percentage (0..100%)CT
0Button 1 [Long Press Repeat 2]Value --> 1-byte scene activate1 Byte18.1 scene controlCT
0Button 1 [Long Press Repeat 2]Value --> 2-byte unsigned2 Bytes7.1 pulsesCT
0Button 1 [Long Press Repeat 2]Value --> 2-byte signed2 Bytes8.1 pulses differenceCT
0Button 1 [Long Press Repeat 2]Value --> 2-byte float2 Bytes9.1 temperature (°C)CT
0Button 1 [Long Press Repeat 2]Value --> 4-byte unsigned4 Bytes12.1 counter pulses (unsigned)CT
0Button 1 [Long Press Repeat 2]Value --> 4-byte signed4 Bytes13.1 counter pulses (signed)CT
0Button 1 [Long Press Repeat 2]Value --> 4-byte float4 Bytes14.5 amplitudeCT
0Button 1 [Long Press Repeat 2]Value <-> 1-byte counter/sequence1 Byte5.10 counter pulses (0..255)CWT
0Button 1 [Long Press Repeat 2]Value --> 2-bit priority control2 Bit2.1 switch controlCT
0Button 1 [Long Press Repeat 2]Value --> 4-bit dimming control4 Bit3.7 dimming controlCT
0Button 1 [Long Press Repeat 2]Value --> 4-bit blind control4 Bit3.8 blind controlCT
0Button 1 [Long Press Repeat 2]Value --> 1-byte scene learn1 Byte18.1 scene controlCT
0Button 1 [Long Press Repeat 2]Value --> 3-byte color3 Bytes232.600 RGB value 3x(0..255)CT
0Button 1 [Long Press Release 2]Value --> 1-bit1 Bit1.1 switchCT
0Button 1 [Long Press Release 2]Value --> 1-bit HVAC control mode1 Bit1.100 cooling/heatingCT
0Button 1 [Long Press Release 2]Value <-> 1-bit toggle1 Bit1.1 switchCWT
0Button 1 [Long Press Release 2]Value --> 1-byte unsigned1 Byte5.10 counter pulses (0..255)CT
0Button 1 [Long Press Release 2]Value --> 1-byte signed1 Byte6.10 counter pulses (-128..127)CT
0Button 1 [Long Press Release 2]Value --> 1-byte HVAC operating mode1 Byte20.102 HVAC modeCT
0Button 1 [Long Press Release 2]Value --> 1-byte percentage1 Byte5.1 percentage (0..100%)CT
0Button 1 [Long Press Release 2]Value --> 1-byte scene activate1 Byte18.1 scene controlCT
0Button 1 [Long Press Release 2]Value --> 2-byte unsigned2 Bytes7.1 pulsesCT
0Button 1 [Long Press Release 2]Value --> 2-byte signed2 Bytes8.1 pulses differenceCT
0Button 1 [Long Press Release 2]Value --> 2-byte float2 Bytes9.1 temperature (°C)CT
0Button 1 [Long Press Release 2]Value --> 4-byte unsigned4 Bytes12.1 counter pulses (unsigned)CT
0Button 1 [Long Press Release 2]Value --> 4-byte signed4 Bytes13.1 counter pulses (signed)CT
0Button 1 [Long Press Release 2]Value --> 4-byte float4 Bytes14.5 amplitudeCT
0Button 1 [Long Press Release 2]Value <-> 1-byte counter/sequence1 Byte5.10 counter pulses (0..255)CWT
0Button 1 [Long Press Release 2]Value --> 2-bit priority control2 Bit2.1 switch controlCT
0Button 1 [Long Press Release 2]Value --> 4-bit dimming control4 Bit3.7 dimming controlCT
0Button 1 [Long Press Release 2]Value --> 4-bit blind control4 Bit3.8 blind controlCT
0Button 1 [Long Press Release 2]Value --> 1-byte scene learn1 Byte18.1 scene controlCT
0Button 1 [Long Press Release 2]Value --> 3-byte color3 Bytes232.600 RGB value 3x(0..255)CT
0Button 1 [Short Press 3]Value --> 1-bit1 Bit1.1 switchCT
0Button 1 [Short Press 3]Value --> 1-bit HVAC control mode1 Bit1.100 cooling/heatingCT
0Button 1 [Short Press 3]Value <-> 1-bit toggle1 Bit1.1 switchCWT
0Button 1 [Short Press 3]Value --> 1-byte unsigned1 Byte5.10 counter pulses (0..255)CT
0Button 1 [Short Press 3]Value --> 1-byte signed1 Byte6.10 counter pulses (-128..127)CT
0Button 1 [Short Press 3]Value --> 1-byte HVAC operating mode1 Byte20.102 HVAC modeCT
0Button 1 [Short Press 3]Value --> 1-byte percentage1 Byte5.1 percentage (0..100%)CT
0Button 1 [Short Press 3]Value --> 1-byte scene activate1 Byte18.1 scene controlCT
0Button 1 [Short Press 3]Value --> 2-byte unsigned2 Bytes7.1 pulsesCT
0Button 1 [Short Press 3]Value --> 2-byte signed2 Bytes8.1 pulses differenceCT
0Button 1 [Short Press 3]Value --> 2-byte float2 Bytes9.1 temperature (°C)CT
0Button 1 [Short Press 3]Value --> 4-byte unsigned4 Bytes12.1 counter pulses (unsigned)CT
0Button 1 [Short Press 3]Value --> 4-byte signed4 Bytes13.1 counter pulses (signed)CT
0Button 1 [Short Press 3]Value --> 4-byte float4 Bytes14.5 amplitudeCT
0Button 1 [Short Press 3]Value <-> 1-byte counter/sequence1 Byte5.10 counter pulses (0..255)CWT
0Button 1 [Short Press 3]Value --> 2-bit priority control2 Bit2.1 switch controlCT
0Button 1 [Short Press 3]Value --> 4-bit dimming control4 Bit3.7 dimming controlCT
0Button 1 [Short Press 3]Value --> 4-bit blind control4 Bit3.8 blind controlCT
0Button 1 [Short Press 3]Value --> 1-byte scene learn1 Byte18.1 scene controlCT
0Button 1 [Short Press 3]Value --> 3-byte color3 Bytes232.600 RGB value 3x(0..255)CT
0Button 1 [Double Press 3]Value --> 1-bit1 Bit1.1 switchCT
0Button 1 [Double Press 3]Value --> 1-bit HVAC control mode1 Bit1.100 cooling/heatingCT
0Button 1 [Double Press 3]Value <-> 1-bit toggle1 Bit1.1 switchCWT
0Button 1 [Double Press 3]Value --> 1-byte unsigned1 Byte5.10 counter pulses (0..255)CT
0Button 1 [Double Press 3]Value --> 1-byte signed1 Byte6.10 counter pulses (-128..127)CT
0Button 1 [Double Press 3]Value --> 1-byte HVAC operating mode1 Byte20.102 HVAC modeCT
0Button 1 [Double Press 3]Value --> 1-byte percentage1 Byte5.1 percentage (0..100%)CT
0Button 1 [Double Press 3]Value --> 1-byte scene activate1 Byte18.1 scene controlCT
0Button 1 [Double Press 3]Value --> 2-byte unsigned2 Bytes7.1 pulsesCT
0Button 1 [Double Press 3]Value --> 2-byte signed2 Bytes8.1 pulses differenceCT
0Button 1 [Double Press 3]Value --> 2-byte float2 Bytes9.1 temperature (°C)CT
0Button 1 [Double Press 3]Value --> 4-byte unsigned4 Bytes12.1 counter pulses (unsigned)CT
0Button 1 [Double Press 3]Value --> 4-byte signed4 Bytes13.1 counter pulses (signed)CT
0Button 1 [Double Press 3]Value --> 4-byte float4 Bytes14.5 amplitudeCT
0Button 1 [Double Press 3]Value <-> 1-byte counter/sequence1 Byte5.10 counter pulses (0..255)CWT
0Button 1 [Double Press 3]Value --> 2-bit priority control2 Bit2.1 switch controlCT
0Button 1 [Double Press 3]Value --> 4-bit dimming control4 Bit3.7 dimming controlCT
0Button 1 [Double Press 3]Value --> 4-bit blind control4 Bit3.8 blind controlCT
0Button 1 [Double Press 3]Value --> 1-byte scene learn1 Byte18.1 scene controlCT
0Button 1 [Double Press 3]Value --> 3-byte color3 Bytes232.600 RGB value 3x(0..255)CT
0Button 1 [Triple Press 3]Value --> 1-bit1 Bit1.1 switchCT
0Button 1 [Triple Press 3]Value --> 1-bit HVAC control mode1 Bit1.100 cooling/heatingCT
0Button 1 [Triple Press 3]Value <-> 1-bit toggle1 Bit1.1 switchCWT
0Button 1 [Triple Press 3]Value --> 1-byte unsigned1 Byte5.10 counter pulses (0..255)CT
0Button 1 [Triple Press 3]Value --> 1-byte signed1 Byte6.10 counter pulses (-128..127)CT
0Button 1 [Triple Press 3]Value --> 1-byte HVAC operating mode1 Byte20.102 HVAC modeCT
0Button 1 [Triple Press 3]Value --> 1-byte percentage1 Byte5.1 percentage (0..100%)CT
0Button 1 [Triple Press 3]Value --> 1-byte scene activate1 Byte18.1 scene controlCT
0Button 1 [Triple Press 3]Value --> 2-byte unsigned2 Bytes7.1 pulsesCT
0Button 1 [Triple Press 3]Value --> 2-byte signed2 Bytes8.1 pulses differenceCT
0Button 1 [Triple Press 3]Value --> 2-byte float2 Bytes9.1 temperature (°C)CT
0Button 1 [Triple Press 3]Value --> 4-byte unsigned4 Bytes12.1 counter pulses (unsigned)CT
0Button 1 [Triple Press 3]Value --> 4-byte signed4 Bytes13.1 counter pulses (signed)CT
0Button 1 [Triple Press 3]Value --> 4-byte float4 Bytes14.5 amplitudeCT
0Button 1 [Triple Press 3]Value <-> 1-byte counter/sequence1 Byte5.10 counter pulses (0..255)CWT
0Button 1 [Triple Press 3]Value --> 2-bit priority control2 Bit2.1 switch controlCT
0Button 1 [Triple Press 3]Value --> 4-bit dimming control4 Bit3.7 dimming controlCT
0Button 1 [Triple Press 3]Value --> 4-bit blind control4 Bit3.8 blind controlCT
0Button 1 [Triple Press 3]Value --> 1-byte scene learn1 Byte18.1 scene controlCT
0Button 1 [Triple Press 3]Value --> 3-byte color3 Bytes232.600 RGB value 3x(0..255)CT
0Button 1 [Long Press 3]Value --> 1-bit1 Bit1.1 switchCT
0Button 1 [Long Press 3]Value --> 1-bit HVAC control mode1 Bit1.100 cooling/heatingCT
0Button 1 [Long Press 3]Value <-> 1-bit toggle1 Bit1.1 switchCWT
0Button 1 [Long Press 3]Value --> 1-byte unsigned1 Byte5.10 counter pulses (0..255)CT
0Button 1 [Long Press 3]Value --> 1-byte signed1 Byte6.10 counter pulses (-128..127)CT
0Button 1 [Long Press 3]Value --> 1-byte HVAC operating mode1 Byte20.102 HVAC modeCT
0Button 1 [Long Press 3]Value --> 1-byte percentage1 Byte5.1 percentage (0..100%)CT
0Button 1 [Long Press 3]Value --> 1-byte scene activate1 Byte18.1 scene controlCT
0Button 1 [Long Press 3]Value --> 2-byte unsigned2 Bytes7.1 pulsesCT
0Button 1 [Long Press 3]Value --> 2-byte signed2 Bytes8.1 pulses differenceCT
0Button 1 [Long Press 3]Value --> 2-byte float2 Bytes9.1 temperature (°C)CT
0Button 1 [Long Press 3]Value --> 4-byte unsigned4 Bytes12.1 counter pulses (unsigned)CT
0Button 1 [Long Press 3]Value --> 4-byte signed4 Bytes13.1 counter pulses (signed)CT
0Button 1 [Long Press 3]Value --> 4-byte float4 Bytes14.5 amplitudeCT
0Button 1 [Long Press 3]Value <-> 1-byte counter/sequence1 Byte5.10 counter pulses (0..255)CWT
0Button 1 [Long Press 3]Value --> 2-bit priority control2 Bit2.1 switch controlCT
0Button 1 [Long Press 3]Value --> 4-bit dimming control4 Bit3.7 dimming controlCT
0Button 1 [Long Press 3]Value --> 4-bit blind control4 Bit3.8 blind controlCT
0Button 1 [Long Press 3]Value --> 1-byte scene learn1 Byte18.1 scene controlCT
0Button 1 [Long Press 3]Value --> 3-byte color3 Bytes232.600 RGB value 3x(0..255)CT
0Button 1 [Long Press Repeat 3]Value --> 1-bit1 Bit1.1 switchCT
0Button 1 [Long Press Repeat 3]Value --> 1-bit HVAC control mode1 Bit1.100 cooling/heatingCT
0Button 1 [Long Press Repeat 3]Value <-> 1-bit toggle1 Bit1.1 switchCWT
0Button 1 [Long Press Repeat 3]Value --> 1-byte unsigned1 Byte5.10 counter pulses (0..255)CT
0Button 1 [Long Press Repeat 3]Value --> 1-byte signed1 Byte6.10 counter pulses (-128..127)CT
0Button 1 [Long Press Repeat 3]Value --> 1-byte HVAC operating mode1 Byte20.102 HVAC modeCT
0Button 1 [Long Press Repeat 3]Value --> 1-byte percentage1 Byte5.1 percentage (0..100%)CT
0Button 1 [Long Press Repeat 3]Value --> 1-byte scene activate1 Byte18.1 scene controlCT
0Button 1 [Long Press Repeat 3]Value --> 2-byte unsigned2 Bytes7.1 pulsesCT
0Button 1 [Long Press Repeat 3]Value --> 2-byte signed2 Bytes8.1 pulses differenceCT
0Button 1 [Long Press Repeat 3]Value --> 2-byte float2 Bytes9.1 temperature (°C)CT
0Button 1 [Long Press Repeat 3]Value --> 4-byte unsigned4 Bytes12.1 counter pulses (unsigned)CT
0Button 1 [Long Press Repeat 3]Value --> 4-byte signed4 Bytes13.1 counter pulses (signed)CT
0Button 1 [Long Press Repeat 3]Value --> 4-byte float4 Bytes14.5 amplitudeCT
0Button 1 [Long Press Repeat 3]Value <-> 1-byte counter/sequence1 Byte5.10 counter pulses (0..255)CWT
0Button 1 [Long Press Repeat 3]Value --> 2-bit priority control2 Bit2.1 switch controlCT
0Button 1 [Long Press Repeat 3]Value --> 4-bit dimming control4 Bit3.7 dimming controlCT
0Button 1 [Long Press Repeat 3]Value --> 4-bit blind control4 Bit3.8 blind controlCT
0Button 1 [Long Press Repeat 3]Value --> 1-byte scene learn1 Byte18.1 scene controlCT
0Button 1 [Long Press Repeat 3]Value --> 3-byte color3 Bytes232.600 RGB value 3x(0..255)CT
0Button 1 [Long Press Release 3]Value --> 1-bit1 Bit1.1 switchCT
0Button 1 [Long Press Release 3]Value --> 1-bit HVAC control mode1 Bit1.100 cooling/heatingCT
0Button 1 [Long Press Release 3]Value <-> 1-bit toggle1 Bit1.1 switchCWT
0Button 1 [Long Press Release 3]Value --> 1-byte unsigned1 Byte5.10 counter pulses (0..255)CT
0Button 1 [Long Press Release 3]Value --> 1-byte signed1 Byte6.10 counter pulses (-128..127)CT
0Button 1 [Long Press Release 3]Value --> 1-byte HVAC operating mode1 Byte20.102 HVAC modeCT
0Button 1 [Long Press Release 3]Value --> 1-byte percentage1 Byte5.1 percentage (0..100%)CT
0Button 1 [Long Press Release 3]Value --> 1-byte scene activate1 Byte18.1 scene controlCT
0Button 1 [Long Press Release 3]Value --> 2-byte unsigned2 Bytes7.1 pulsesCT
0Button 1 [Long Press Release 3]Value --> 2-byte signed2 Bytes8.1 pulses differenceCT
0Button 1 [Long Press Release 3]Value --> 2-byte float2 Bytes9.1 temperature (°C)CT
0Button 1 [Long Press Release 3]Value --> 4-byte unsigned4 Bytes12.1 counter pulses (unsigned)CT
0Button 1 [Long Press Release 3]Value --> 4-byte signed4 Bytes13.1 counter pulses (signed)CT
0Button 1 [Long Press Release 3]Value --> 4-byte float4 Bytes14.5 amplitudeCT
0Button 1 [Long Press Release 3]Value <-> 1-byte counter/sequence1 Byte5.10 counter pulses (0..255)CWT
0Button 1 [Long Press Release 3]Value --> 2-bit priority control2 Bit2.1 switch controlCT
0Button 1 [Long Press Release 3]Value --> 4-bit dimming control4 Bit3.7 dimming controlCT
0Button 1 [Long Press Release 3]Value --> 4-bit blind control4 Bit3.8 blind controlCT
0Button 1 [Long Press Release 3]Value --> 1-byte scene learn1 Byte18.1 scene controlCT
0Button 1 [Long Press Release 3]Value --> 3-byte color3 Bytes232.600 RGB value 3x(0..255)CT
0Button 1 [Short Press 4]Value --> 1-bit1 Bit1.1 switchCT
0Button 1 [Short Press 4]Value --> 1-bit HVAC control mode1 Bit1.100 cooling/heatingCT
0Button 1 [Short Press 4]Value <-> 1-bit toggle1 Bit1.1 switchCWT
0Button 1 [Short Press 4]Value --> 1-byte unsigned1 Byte5.10 counter pulses (0..255)CT
0Button 1 [Short Press 4]Value --> 1-byte signed1 Byte6.10 counter pulses (-128..127)CT
0Button 1 [Short Press 4]Value --> 1-byte HVAC operating mode1 Byte20.102 HVAC modeCT
0Button 1 [Short Press 4]Value --> 1-byte percentage1 Byte5.1 percentage (0..100%)CT
0Button 1 [Short Press 4]Value --> 1-byte scene activate1 Byte18.1 scene controlCT
0Button 1 [Short Press 4]Value --> 2-byte unsigned2 Bytes7.1 pulsesCT
0Button 1 [Short Press 4]Value --> 2-byte signed2 Bytes8.1 pulses differenceCT
0Button 1 [Short Press 4]Value --> 2-byte float2 Bytes9.1 temperature (°C)CT
0Button 1 [Short Press 4]Value --> 4-byte unsigned4 Bytes12.1 counter pulses (unsigned)CT
0Button 1 [Short Press 4]Value --> 4-byte signed4 Bytes13.1 counter pulses (signed)CT
0Button 1 [Short Press 4]Value --> 4-byte float4 Bytes14.5 amplitudeCT
0Button 1 [Short Press 4]Value <-> 1-byte counter/sequence1 Byte5.10 counter pulses (0..255)CWT
0Button 1 [Short Press 4]Value --> 2-bit priority control2 Bit2.1 switch controlCT
0Button 1 [Short Press 4]Value --> 4-bit dimming control4 Bit3.7 dimming controlCT
0Button 1 [Short Press 4]Value --> 4-bit blind control4 Bit3.8 blind controlCT
0Button 1 [Short Press 4]Value --> 1-byte scene learn1 Byte18.1 scene controlCT
0Button 1 [Short Press 4]Value --> 3-byte color3 Bytes232.600 RGB value 3x(0..255)CT
0Button 1 [Double Press 4]Value --> 1-bit1 Bit1.1 switchCT
0Button 1 [Double Press 4]Value --> 1-bit HVAC control mode1 Bit1.100 cooling/heatingCT
0Button 1 [Double Press 4]Value <-> 1-bit toggle1 Bit1.1 switchCWT
0Button 1 [Double Press 4]Value --> 1-byte unsigned1 Byte5.10 counter pulses (0..255)CT
0Button 1 [Double Press 4]Value --> 1-byte signed1 Byte6.10 counter pulses (-128..127)CT
0Button 1 [Double Press 4]Value --> 1-byte HVAC operating mode1 Byte20.102 HVAC modeCT
0Button 1 [Double Press 4]Value --> 1-byte percentage1 Byte5.1 percentage (0..100%)CT
0Button 1 [Double Press 4]Value --> 1-byte scene activate1 Byte18.1 scene controlCT
0Button 1 [Double Press 4]Value --> 2-byte unsigned2 Bytes7.1 pulsesCT
0Button 1 [Double Press 4]Value --> 2-byte signed2 Bytes8.1 pulses differenceCT
0Button 1 [Double Press 4]Value --> 2-byte float2 Bytes9.1 temperature (°C)CT
0Button 1 [Double Press 4]Value --> 4-byte unsigned4 Bytes12.1 counter pulses (unsigned)CT
0Button 1 [Double Press 4]Value --> 4-byte signed4 Bytes13.1 counter pulses (signed)CT
0Button 1 [Double Press 4]Value --> 4-byte float4 Bytes14.5 amplitudeCT
0Button 1 [Double Press 4]Value <-> 1-byte counter/sequence1 Byte5.10 counter pulses (0..255)CWT
0Button 1 [Double Press 4]Value --> 2-bit priority control2 Bit2.1 switch controlCT
0Button 1 [Double Press 4]Value --> 4-bit dimming control4 Bit3.7 dimming controlCT
0Button 1 [Double Press 4]Value --> 4-bit blind control4 Bit3.8 blind controlCT
0Button 1 [Double Press 4]Value --> 1-byte scene learn1 Byte18.1 scene controlCT
0Button 1 [Double Press 4]Value --> 3-byte color3 Bytes232.600 RGB value 3x(0..255)CT
0Button 1 [Triple Press 4]Value --> 1-bit1 Bit1.1 switchCT
0Button 1 [Triple Press 4]Value --> 1-bit HVAC control mode1 Bit1.100 cooling/heatingCT
0Button 1 [Triple Press 4]Value <-> 1-bit toggle1 Bit1.1 switchCWT
0Button 1 [Triple Press 4]Value --> 1-byte unsigned1 Byte5.10 counter pulses (0..255)CT
0Button 1 [Triple Press 4]Value --> 1-byte signed1 Byte6.10 counter pulses (-128..127)CT
0Button 1 [Triple Press 4]Value --> 1-byte HVAC operating mode1 Byte20.102 HVAC modeCT
0Button 1 [Triple Press 4]Value --> 1-byte percentage1 Byte5.1 percentage (0..100%)CT
0Button 1 [Triple Press 4]Value --> 1-byte scene activate1 Byte18.1 scene controlCT
0Button 1 [Triple Press 4]Value --> 2-byte unsigned2 Bytes7.1 pulsesCT
0Button 1 [Triple Press 4]Value --> 2-byte signed2 Bytes8.1 pulses differenceCT
0Button 1 [Triple Press 4]Value --> 2-byte float2 Bytes9.1 temperature (°C)CT
0Button 1 [Triple Press 4]Value --> 4-byte unsigned4 Bytes12.1 counter pulses (unsigned)CT
0Button 1 [Triple Press 4]Value --> 4-byte signed4 Bytes13.1 counter pulses (signed)CT
0Button 1 [Triple Press 4]Value --> 4-byte float4 Bytes14.5 amplitudeCT
0Button 1 [Triple Press 4]Value <-> 1-byte counter/sequence1 Byte5.10 counter pulses (0..255)CWT
0Button 1 [Triple Press 4]Value --> 2-bit priority control2 Bit2.1 switch controlCT
0Button 1 [Triple Press 4]Value --> 4-bit dimming control4 Bit3.7 dimming controlCT
0Button 1 [Triple Press 4]Value --> 4-bit blind control4 Bit3.8 blind controlCT
0Button 1 [Triple Press 4]Value --> 1-byte scene learn1 Byte18.1 scene controlCT
0Button 1 [Triple Press 4]Value --> 3-byte color3 Bytes232.600 RGB value 3x(0..255)CT
0Button 1 [Long Press 4]Value --> 1-bit1 Bit1.1 switchCT
0Button 1 [Long Press 4]Value --> 1-bit HVAC control mode1 Bit1.100 cooling/heatingCT
0Button 1 [Long Press 4]Value <-> 1-bit toggle1 Bit1.1 switchCWT
0Button 1 [Long Press 4]Value --> 1-byte unsigned1 Byte5.10 counter pulses (0..255)CT
0Button 1 [Long Press 4]Value --> 1-byte signed1 Byte6.10 counter pulses (-128..127)CT
0Button 1 [Long Press 4]Value --> 1-byte HVAC operating mode1 Byte20.102 HVAC modeCT
0Button 1 [Long Press 4]Value --> 1-byte percentage1 Byte5.1 percentage (0..100%)CT
0Button 1 [Long Press 4]Value --> 1-byte scene activate1 Byte18.1 scene controlCT
0Button 1 [Long Press 4]Value --> 2-byte unsigned2 Bytes7.1 pulsesCT
0Button 1 [Long Press 4]Value --> 2-byte signed2 Bytes8.1 pulses differenceCT
0Button 1 [Long Press 4]Value --> 2-byte float2 Bytes9.1 temperature (°C)CT
0Button 1 [Long Press 4]Value --> 4-byte unsigned4 Bytes12.1 counter pulses (unsigned)CT
0Button 1 [Long Press 4]Value --> 4-byte signed4 Bytes13.1 counter pulses (signed)CT
0Button 1 [Long Press 4]Value --> 4-byte float4 Bytes14.5 amplitudeCT
0Button 1 [Long Press 4]Value <-> 1-byte counter/sequence1 Byte5.10 counter pulses (0..255)CWT
0Button 1 [Long Press 4]Value --> 2-bit priority control2 Bit2.1 switch controlCT
0Button 1 [Long Press 4]Value --> 4-bit dimming control4 Bit3.7 dimming controlCT
0Button 1 [Long Press 4]Value --> 4-bit blind control4 Bit3.8 blind controlCT
0Button 1 [Long Press 4]Value --> 1-byte scene learn1 Byte18.1 scene controlCT
0Button 1 [Long Press 4]Value --> 3-byte color3 Bytes232.600 RGB value 3x(0..255)CT
0Button 1 [Long Press Repeat 4]Value --> 1-bit1 Bit1.1 switchCT
0Button 1 [Long Press Repeat 4]Value --> 1-bit HVAC control mode1 Bit1.100 cooling/heatingCT
0Button 1 [Long Press Repeat 4]Value <-> 1-bit toggle1 Bit1.1 switchCWT
0Button 1 [Long Press Repeat 4]Value --> 1-byte unsigned1 Byte5.10 counter pulses (0..255)CT
0Button 1 [Long Press Repeat 4]Value --> 1-byte signed1 Byte6.10 counter pulses (-128..127)CT
0Button 1 [Long Press Repeat 4]Value --> 1-byte HVAC operating mode1 Byte20.102 HVAC modeCT
0Button 1 [Long Press Repeat 4]Value --> 1-byte percentage1 Byte5.1 percentage (0..100%)CT
0Button 1 [Long Press Repeat 4]Value --> 1-byte scene activate1 Byte18.1 scene controlCT
0Button 1 [Long Press Repeat 4]Value --> 2-byte unsigned2 Bytes7.1 pulsesCT
0Button 1 [Long Press Repeat 4]Value --> 2-byte signed2 Bytes8.1 pulses differenceCT
0Button 1 [Long Press Repeat 4]Value --> 2-byte float2 Bytes9.1 temperature (°C)CT
0Button 1 [Long Press Repeat 4]Value --> 4-byte unsigned4 Bytes12.1 counter pulses (unsigned)CT
0Button 1 [Long Press Repeat 4]Value --> 4-byte signed4 Bytes13.1 counter pulses (signed)CT
0Button 1 [Long Press Repeat 4]Value --> 4-byte float4 Bytes14.5 amplitudeCT
0Button 1 [Long Press Repeat 4]Value <-> 1-byte counter/sequence1 Byte5.10 counter pulses (0..255)CWT
0Button 1 [Long Press Repeat 4]Value --> 2-bit priority control2 Bit2.1 switch controlCT
0Button 1 [Long Press Repeat 4]Value --> 4-bit dimming control4 Bit3.7 dimming controlCT
0Button 1 [Long Press Repeat 4]Value --> 4-bit blind control4 Bit3.8 blind controlCT
0Button 1 [Long Press Repeat 4]Value --> 1-byte scene learn1 Byte18.1 scene controlCT
0Button 1 [Long Press Repeat 4]Value --> 3-byte color3 Bytes232.600 RGB value 3x(0..255)CT
0Button 1 [Long Press Release 4]Value --> 1-bit1 Bit1.1 switchCT
0Button 1 [Long Press Release 4]Value --> 1-bit HVAC control mode1 Bit1.100 cooling/heatingCT
0Button 1 [Long Press Release 4]Value <-> 1-bit toggle1 Bit1.1 switchCWT
0Button 1 [Long Press Release 4]Value --> 1-byte unsigned1 Byte5.10 counter pulses (0..255)CT
0Button 1 [Long Press Release 4]Value --> 1-byte signed1 Byte6.10 counter pulses (-128..127)CT
0Button 1 [Long Press Release 4]Value --> 1-byte HVAC operating mode1 Byte20.102 HVAC modeCT
0Button 1 [Long Press Release 4]Value --> 1-byte percentage1 Byte5.1 percentage (0..100%)CT
0Button 1 [Long Press Release 4]Value --> 1-byte scene activate1 Byte18.1 scene controlCT
0Button 1 [Long Press Release 4]Value --> 2-byte unsigned2 Bytes7.1 pulsesCT
0Button 1 [Long Press Release 4]Value --> 2-byte signed2 Bytes8.1 pulses differenceCT
0Button 1 [Long Press Release 4]Value --> 2-byte float2 Bytes9.1 temperature (°C)CT
0Button 1 [Long Press Release 4]Value --> 4-byte unsigned4 Bytes12.1 counter pulses (unsigned)CT
0Button 1 [Long Press Release 4]Value --> 4-byte signed4 Bytes13.1 counter pulses (signed)CT
0Button 1 [Long Press Release 4]Value --> 4-byte float4 Bytes14.5 amplitudeCT
0Button 1 [Long Press Release 4]Value <-> 1-byte counter/sequence1 Byte5.10 counter pulses (0..255)CWT
0Button 1 [Long Press Release 4]Value --> 2-bit priority control2 Bit2.1 switch controlCT
0Button 1 [Long Press Release 4]Value --> 4-bit dimming control4 Bit3.7 dimming controlCT
0Button 1 [Long Press Release 4]Value --> 4-bit blind control4 Bit3.8 blind controlCT
0Button 1 [Long Press Release 4]Value --> 1-byte scene learn1 Byte18.1 scene controlCT
0Button 1 [Long Press Release 4]Value --> 3-byte color3 Bytes232.600 RGB value 3x(0..255)CT
0Button 2 [Short Press 1]Value --> 1-bit1 Bit1.1 switchCT
0Button 2 [Short Press 1]Value --> 1-bit HVAC control mode1 Bit1.100 cooling/heatingCT
0Button 2 [Short Press 1]Value <-> 1-bit toggle1 Bit1.1 switchCWT
0Button 2 [Short Press 1]Value --> 1-byte unsigned1 Byte5.10 counter pulses (0..255)CT
0Button 2 [Short Press 1]Value --> 1-byte signed1 Byte6.10 counter pulses (-128..127)CT
0Button 2 [Short Press 1]Value --> 1-byte HVAC operating mode1 Byte20.102 HVAC modeCT
0Button 2 [Short Press 1]Value --> 1-byte percentage1 Byte5.1 percentage (0..100%)CT
0Button 2 [Short Press 1]Value --> 1-byte scene activate1 Byte18.1 scene controlCT
0Button 2 [Short Press 1]Value --> 2-byte unsigned2 Bytes7.1 pulsesCT
0Button 2 [Short Press 1]Value --> 2-byte signed2 Bytes8.1 pulses differenceCT
0Button 2 [Short Press 1]Value --> 2-byte float2 Bytes9.1 temperature (°C)CT
0Button 2 [Short Press 1]Value --> 4-byte unsigned4 Bytes12.1 counter pulses (unsigned)CT
0Button 2 [Short Press 1]Value --> 4-byte signed4 Bytes13.1 counter pulses (signed)CT
0Button 2 [Short Press 1]Value --> 4-byte float4 Bytes14.5 amplitudeCT
0Button 2 [Short Press 1]Value <-> 1-byte counter/sequence1 Byte5.10 counter pulses (0..255)CWT
0Button 2 [Short Press 1]Value --> 2-bit priority control2 Bit2.1 switch controlCT
0Button 2 [Short Press 1]Value --> 4-bit dimming control4 Bit3.7 dimming controlCT
0Button 2 [Short Press 1]Value --> 4-bit blind control4 Bit3.8 blind controlCT
0Button 2 [Short Press 1]Value --> 1-byte scene learn1 Byte18.1 scene controlCT
0Button 2 [Short Press 1]Value --> 3-byte color3 Bytes232.600 RGB value 3x(0..255)CT
0Button 2 [Double Press 1]Value --> 1-bit1 Bit1.1 switchCT
0Button 2 [Double Press 1]Value --> 1-bit HVAC control mode1 Bit1.100 cooling/heatingCT
0Button 2 [Double Press 1]Value <-> 1-bit toggle1 Bit1.1 switchCWT
0Button 2 [Double Press 1]Value --> 1-byte unsigned1 Byte5.10 counter pulses (0..255)CT
0Button 2 [Double Press 1]Value --> 1-byte signed1 Byte6.10 counter pulses (-128..127)CT
0Button 2 [Double Press 1]Value --> 1-byte HVAC operating mode1 Byte20.102 HVAC modeCT
0Button 2 [Double Press 1]Value --> 1-byte percentage1 Byte5.1 percentage (0..100%)CT
0Button 2 [Double Press 1]Value --> 1-byte scene activate1 Byte18.1 scene controlCT
0Button 2 [Double Press 1]Value --> 2-byte unsigned2 Bytes7.1 pulsesCT
0Button 2 [Double Press 1]Value --> 2-byte signed2 Bytes8.1 pulses differenceCT
0Button 2 [Double Press 1]Value --> 2-byte float2 Bytes9.1 temperature (°C)CT
0Button 2 [Double Press 1]Value --> 4-byte unsigned4 Bytes12.1 counter pulses (unsigned)CT
0Button 2 [Double Press 1]Value --> 4-byte signed4 Bytes13.1 counter pulses (signed)CT
0Button 2 [Double Press 1]Value --> 4-byte float4 Bytes14.5 amplitudeCT
0Button 2 [Double Press 1]Value <-> 1-byte counter/sequence1 Byte5.10 counter pulses (0..255)CWT
0Button 2 [Double Press 1]Value --> 2-bit priority control2 Bit2.1 switch controlCT
0Button 2 [Double Press 1]Value --> 4-bit dimming control4 Bit3.7 dimming controlCT
0Button 2 [Double Press 1]Value --> 4-bit blind control4 Bit3.8 blind controlCT
0Button 2 [Double Press 1]Value --> 1-byte scene learn1 Byte18.1 scene controlCT
0Button 2 [Double Press 1]Value --> 3-byte color3 Bytes232.600 RGB value 3x(0..255)CT
0Button 2 [Triple Press 1]Value --> 1-bit1 Bit1.1 switchCT
0Button 2 [Triple Press 1]Value --> 1-bit HVAC control mode1 Bit1.100 cooling/heatingCT
0Button 2 [Triple Press 1]Value <-> 1-bit toggle1 Bit1.1 switchCWT
0Button 2 [Triple Press 1]Value --> 1-byte unsigned1 Byte5.10 counter pulses (0..255)CT
0Button 2 [Triple Press 1]Value --> 1-byte signed1 Byte6.10 counter pulses (-128..127)CT
0Button 2 [Triple Press 1]Value --> 1-byte HVAC operating mode1 Byte20.102 HVAC modeCT
0Button 2 [Triple Press 1]Value --> 1-byte percentage1 Byte5.1 percentage (0..100%)CT
0Button 2 [Triple Press 1]Value --> 1-byte scene activate1 Byte18.1 scene controlCT
0Button 2 [Triple Press 1]Value --> 2-byte unsigned2 Bytes7.1 pulsesCT
0Button 2 [Triple Press 1]Value --> 2-byte signed2 Bytes8.1 pulses differenceCT
0Button 2 [Triple Press 1]Value --> 2-byte float2 Bytes9.1 temperature (°C)CT
0Button 2 [Triple Press 1]Value --> 4-byte unsigned4 Bytes12.1 counter pulses (unsigned)CT
0Button 2 [Triple Press 1]Value --> 4-byte signed4 Bytes13.1 counter pulses (signed)CT
0Button 2 [Triple Press 1]Value --> 4-byte float4 Bytes14.5 amplitudeCT
0Button 2 [Triple Press 1]Value <-> 1-byte counter/sequence1 Byte5.10 counter pulses (0..255)CWT
0Button 2 [Triple Press 1]Value --> 2-bit priority control2 Bit2.1 switch controlCT
0Button 2 [Triple Press 1]Value --> 4-bit dimming control4 Bit3.7 dimming controlCT
0Button 2 [Triple Press 1]Value --> 4-bit blind control4 Bit3.8 blind controlCT
0Button 2 [Triple Press 1]Value --> 1-byte scene learn1 Byte18.1 scene controlCT
0Button 2 [Triple Press 1]Value --> 3-byte color3 Bytes232.600 RGB value 3x(0..255)CT
0Button 2 [Long Press 1]Value --> 1-bit1 Bit1.1 switchCT
0Button 2 [Long Press 1]Value --> 1-bit HVAC control mode1 Bit1.100 cooling/heatingCT
0Button 2 [Long Press 1]Value <-> 1-bit toggle1 Bit1.1 switchCWT
0Button 2 [Long Press 1]Value --> 1-byte unsigned1 Byte5.10 counter pulses (0..255)CT
0Button 2 [Long Press 1]Value --> 1-byte signed1 Byte6.10 counter pulses (-128..127)CT
0Button 2 [Long Press 1]Value --> 1-byte HVAC operating mode1 Byte20.102 HVAC modeCT
0Button 2 [Long Press 1]Value --> 1-byte percentage1 Byte5.1 percentage (0..100%)CT
0Button 2 [Long Press 1]Value --> 1-byte scene activate1 Byte18.1 scene controlCT
0Button 2 [Long Press 1]Value --> 2-byte unsigned2 Bytes7.1 pulsesCT
0Button 2 [Long Press 1]Value --> 2-byte signed2 Bytes8.1 pulses differenceCT
0Button 2 [Long Press 1]Value --> 2-byte float2 Bytes9.1 temperature (°C)CT
0Button 2 [Long Press 1]Value --> 4-byte unsigned4 Bytes12.1 counter pulses (unsigned)CT
0Button 2 [Long Press 1]Value --> 4-byte signed4 Bytes13.1 counter pulses (signed)CT
0Button 2 [Long Press 1]Value --> 4-byte float4 Bytes14.5 amplitudeCT
0Button 2 [Long Press 1]Value <-> 1-byte counter/sequence1 Byte5.10 counter pulses (0..255)CWT
0Button 2 [Long Press 1]Value --> 2-bit priority control2 Bit2.1 switch controlCT
0Button 2 [Long Press 1]Value --> 4-bit dimming control4 Bit3.7 dimming controlCT
0Button 2 [Long Press 1]Value --> 4-bit blind control4 Bit3.8 blind controlCT
0Button 2 [Long Press 1]Value --> 1-byte scene learn1 Byte18.1 scene controlCT
0Button 2 [Long Press 1]Value --> 3-byte color3 Bytes232.600 RGB value 3x(0..255)CT
0Button 2 [Long Press Repeat 1]Value --> 1-bit1 Bit1.1 switchCT
0Button 2 [Long Press Repeat 1]Value --> 1-bit HVAC control mode1 Bit1.100 cooling/heatingCT
0Button 2 [Long Press Repeat 1]Value <-> 1-bit toggle1 Bit1.1 switchCWT
0Button 2 [Long Press Repeat 1]Value --> 1-byte unsigned1 Byte5.10 counter pulses (0..255)CT
0Button 2 [Long Press Repeat 1]Value --> 1-byte signed1 Byte6.10 counter pulses (-128..127)CT
0Button 2 [Long Press Repeat 1]Value --> 1-byte HVAC operating mode1 Byte20.102 HVAC modeCT
0Button 2 [Long Press Repeat 1]Value --> 1-byte percentage1 Byte5.1 percentage (0..100%)CT
0Button 2 [Long Press Repeat 1]Value --> 1-byte scene activate1 Byte18.1 scene controlCT
0Button 2 [Long Press Repeat 1]Value --> 2-byte unsigned2 Bytes7.1 pulsesCT
0Button 2 [Long Press Repeat 1]Value --> 2-byte signed2 Bytes8.1 pulses differenceCT
0Button 2 [Long Press Repeat 1]Value --> 2-byte float2 Bytes9.1 temperature (°C)CT
0Button 2 [Long Press Repeat 1]Value --> 4-byte unsigned4 Bytes12.1 counter pulses (unsigned)CT
0Button 2 [Long Press Repeat 1]Value --> 4-byte signed4 Bytes13.1 counter pulses (signed)CT
0Button 2 [Long Press Repeat 1]Value --> 4-byte float4 Bytes14.5 amplitudeCT
0Button 2 [Long Press Repeat 1]Value <-> 1-byte counter/sequence1 Byte5.10 counter pulses (0..255)CWT
0Button 2 [Long Press Repeat 1]Value --> 2-bit priority control2 Bit2.1 switch controlCT
0Button 2 [Long Press Repeat 1]Value --> 4-bit dimming control4 Bit3.7 dimming controlCT
0Button 2 [Long Press Repeat 1]Value --> 4-bit blind control4 Bit3.8 blind controlCT
0Button 2 [Long Press Repeat 1]Value --> 1-byte scene learn1 Byte18.1 scene controlCT
0Button 2 [Long Press Repeat 1]Value --> 3-byte color3 Bytes232.600 RGB value 3x(0..255)CT
0Button 2 [Long Press Release 1]Value --> 1-bit1 Bit1.1 switchCT
0Button 2 [Long Press Release 1]Value --> 1-bit HVAC control mode1 Bit1.100 cooling/heatingCT
0Button 2 [Long Press Release 1]Value <-> 1-bit toggle1 Bit1.1 switchCWT
0Button 2 [Long Press Release 1]Value --> 1-byte unsigned1 Byte5.10 counter pulses (0..255)CT
0Button 2 [Long Press Release 1]Value --> 1-byte signed1 Byte6.10 counter pulses (-128..127)CT
0Button 2 [Long Press Release 1]Value --> 1-byte HVAC operating mode1 Byte20.102 HVAC modeCT
0Button 2 [Long Press Release 1]Value --> 1-byte percentage1 Byte5.1 percentage (0..100%)CT
0Button 2 [Long Press Release 1]Value --> 1-byte scene activate1 Byte18.1 scene controlCT
0Button 2 [Long Press Release 1]Value --> 2-byte unsigned2 Bytes7.1 pulsesCT
0Button 2 [Long Press Release 1]Value --> 2-byte signed2 Bytes8.1 pulses differenceCT
0Button 2 [Long Press Release 1]Value --> 2-byte float2 Bytes9.1 temperature (°C)CT
0Button 2 [Long Press Release 1]Value --> 4-byte unsigned4 Bytes12.1 counter pulses (unsigned)CT
0Button 2 [Long Press Release 1]Value --> 4-byte signed4 Bytes13.1 counter pulses (signed)CT
0Button 2 [Long Press Release 1]Value --> 4-byte float4 Bytes14.5 amplitudeCT
0Button 2 [Long Press Release 1]Value <-> 1-byte counter/sequence1 Byte5.10 counter pulses (0..255)CWT
0Button 2 [Long Press Release 1]Value --> 2-bit priority control2 Bit2.1 switch controlCT
0Button 2 [Long Press Release 1]Value --> 4-bit dimming control4 Bit3.7 dimming controlCT
0Button 2 [Long Press Release 1]Value --> 4-bit blind control4 Bit3.8 blind controlCT
0Button 2 [Long Press Release 1]Value --> 1-byte scene learn1 Byte18.1 scene controlCT
0Button 2 [Long Press Release 1]Value --> 3-byte color3 Bytes232.600 RGB value 3x(0..255)CT
0Button 2 [Short Press 2]Value --> 1-bit1 Bit1.1 switchCT
0Button 2 [Short Press 2]Value --> 1-bit HVAC control mode1 Bit1.100 cooling/heatingCT
0Button 2 [Short Press 2]Value <-> 1-bit toggle1 Bit1.1 switchCWT
0Button 2 [Short Press 2]Value --> 1-byte unsigned1 Byte5.10 counter pulses (0..255)CT
0Button 2 [Short Press 2]Value --> 1-byte signed1 Byte6.10 counter pulses (-128..127)CT
0Button 2 [Short Press 2]Value --> 1-byte HVAC operating mode1 Byte20.102 HVAC modeCT
0Button 2 [Short Press 2]Value --> 1-byte percentage1 Byte5.1 percentage (0..100%)CT
0Button 2 [Short Press 2]Value --> 1-byte scene activate1 Byte18.1 scene controlCT
0Button 2 [Short Press 2]Value --> 2-byte unsigned2 Bytes7.1 pulsesCT
0Button 2 [Short Press 2]Value --> 2-byte signed2 Bytes8.1 pulses differenceCT
0Button 2 [Short Press 2]Value --> 2-byte float2 Bytes9.1 temperature (°C)CT
0Button 2 [Short Press 2]Value --> 4-byte unsigned4 Bytes12.1 counter pulses (unsigned)CT
0Button 2 [Short Press 2]Value --> 4-byte signed4 Bytes13.1 counter pulses (signed)CT
0Button 2 [Short Press 2]Value --> 4-byte float4 Bytes14.5 amplitudeCT
0Button 2 [Short Press 2]Value <-> 1-byte counter/sequence1 Byte5.10 counter pulses (0..255)CWT
0Button 2 [Short Press 2]Value --> 2-bit priority control2 Bit2.1 switch controlCT
0Button 2 [Short Press 2]Value --> 4-bit dimming control4 Bit3.7 dimming controlCT
0Button 2 [Short Press 2]Value --> 4-bit blind control4 Bit3.8 blind controlCT
0Button 2 [Short Press 2]Value --> 1-byte scene learn1 Byte18.1 scene controlCT
0Button 2 [Short Press 2]Value --> 3-byte color3 Bytes232.600 RGB value 3x(0..255)CT
0Button 2 [Double Press 2]Value --> 1-bit1 Bit1.1 switchCT
0Button 2 [Double Press 2]Value --> 1-bit HVAC control mode1 Bit1.100 cooling/heatingCT
0Button 2 [Double Press 2]Value <-> 1-bit toggle1 Bit1.1 switchCWT
0Button 2 [Double Press 2]Value --> 1-byte unsigned1 Byte5.10 counter pulses (0..255)CT
0Button 2 [Double Press 2]Value --> 1-byte signed1 Byte6.10 counter pulses (-128..127)CT
0Button 2 [Double Press 2]Value --> 1-byte HVAC operating mode1 Byte20.102 HVAC modeCT
0Button 2 [Double Press 2]Value --> 1-byte percentage1 Byte5.1 percentage (0..100%)CT
0Button 2 [Double Press 2]Value --> 1-byte scene activate1 Byte18.1 scene controlCT
0Button 2 [Double Press 2]Value --> 2-byte unsigned2 Bytes7.1 pulsesCT
0Button 2 [Double Press 2]Value --> 2-byte signed2 Bytes8.1 pulses differenceCT
0Button 2 [Double Press 2]Value --> 2-byte float2 Bytes9.1 temperature (°C)CT
0Button 2 [Double Press 2]Value --> 4-byte unsigned4 Bytes12.1 counter pulses (unsigned)CT
0Button 2 [Double Press 2]Value --> 4-byte signed4 Bytes13.1 counter pulses (signed)CT
0Button 2 [Double Press 2]Value --> 4-byte float4 Bytes14.5 amplitudeCT
0Button 2 [Double Press 2]Value <-> 1-byte counter/sequence1 Byte5.10 counter pulses (0..255)CWT
0Button 2 [Double Press 2]Value --> 2-bit priority control2 Bit2.1 switch controlCT
0Button 2 [Double Press 2]Value --> 4-bit dimming control4 Bit3.7 dimming controlCT
0Button 2 [Double Press 2]Value --> 4-bit blind control4 Bit3.8 blind controlCT
0Button 2 [Double Press 2]Value --> 1-byte scene learn1 Byte18.1 scene controlCT
0Button 2 [Double Press 2]Value --> 3-byte color3 Bytes232.600 RGB value 3x(0..255)CT
0Button 2 [Triple Press 2]Value --> 1-bit1 Bit1.1 switchCT
0Button 2 [Triple Press 2]Value --> 1-bit HVAC control mode1 Bit1.100 cooling/heatingCT
0Button 2 [Triple Press 2]Value <-> 1-bit toggle1 Bit1.1 switchCWT
0Button 2 [Triple Press 2]Value --> 1-byte unsigned1 Byte5.10 counter pulses (0..255)CT
0Button 2 [Triple Press 2]Value --> 1-byte signed1 Byte6.10 counter pulses (-128..127)CT
0Button 2 [Triple Press 2]Value --> 1-byte HVAC operating mode1 Byte20.102 HVAC modeCT
0Button 2 [Triple Press 2]Value --> 1-byte percentage1 Byte5.1 percentage (0..100%)CT
0Button 2 [Triple Press 2]Value --> 1-byte scene activate1 Byte18.1 scene controlCT
0Button 2 [Triple Press 2]Value --> 2-byte unsigned2 Bytes7.1 pulsesCT
0Button 2 [Triple Press 2]Value --> 2-byte signed2 Bytes8.1 pulses differenceCT
0Button 2 [Triple Press 2]Value --> 2-byte float2 Bytes9.1 temperature (°C)CT
0Button 2 [Triple Press 2]Value --> 4-byte unsigned4 Bytes12.1 counter pulses (unsigned)CT
0Button 2 [Triple Press 2]Value --> 4-byte signed4 Bytes13.1 counter pulses (signed)CT
0Button 2 [Triple Press 2]Value --> 4-byte float4 Bytes14.5 amplitudeCT
0Button 2 [Triple Press 2]Value <-> 1-byte counter/sequence1 Byte5.10 counter pulses (0..255)CWT
0Button 2 [Triple Press 2]Value --> 2-bit priority control2 Bit2.1 switch controlCT
0Button 2 [Triple Press 2]Value --> 4-bit dimming control4 Bit3.7 dimming controlCT
0Button 2 [Triple Press 2]Value --> 4-bit blind control4 Bit3.8 blind controlCT
0Button 2 [Triple Press 2]Value --> 1-byte scene learn1 Byte18.1 scene controlCT
0Button 2 [Triple Press 2]Value --> 3-byte color3 Bytes232.600 RGB value 3x(0..255)CT
0Button 2 [Long Press 2]Value --> 1-bit1 Bit1.1 switchCT
0Button 2 [Long Press 2]Value --> 1-bit HVAC control mode1 Bit1.100 cooling/heatingCT
0Button 2 [Long Press 2]Value <-> 1-bit toggle1 Bit1.1 switchCWT
0Button 2 [Long Press 2]Value --> 1-byte unsigned1 Byte5.10 counter pulses (0..255)CT
0Button 2 [Long Press 2]Value --> 1-byte signed1 Byte6.10 counter pulses (-128..127)CT
0Button 2 [Long Press 2]Value --> 1-byte HVAC operating mode1 Byte20.102 HVAC modeCT
0Button 2 [Long Press 2]Value --> 1-byte percentage1 Byte5.1 percentage (0..100%)CT
0Button 2 [Long Press 2]Value --> 1-byte scene activate1 Byte18.1 scene controlCT
0Button 2 [Long Press 2]Value --> 2-byte unsigned2 Bytes7.1 pulsesCT
0Button 2 [Long Press 2]Value --> 2-byte signed2 Bytes8.1 pulses differenceCT
0Button 2 [Long Press 2]Value --> 2-byte float2 Bytes9.1 temperature (°C)CT
0Button 2 [Long Press 2]Value --> 4-byte unsigned4 Bytes12.1 counter pulses (unsigned)CT
0Button 2 [Long Press 2]Value --> 4-byte signed4 Bytes13.1 counter pulses (signed)CT
0Button 2 [Long Press 2]Value --> 4-byte float4 Bytes14.5 amplitudeCT
0Button 2 [Long Press 2]Value <-> 1-byte counter/sequence1 Byte5.10 counter pulses (0..255)CWT
0Button 2 [Long Press 2]Value --> 2-bit priority control2 Bit2.1 switch controlCT
0Button 2 [Long Press 2]Value --> 4-bit dimming control4 Bit3.7 dimming controlCT
0Button 2 [Long Press 2]Value --> 4-bit blind control4 Bit3.8 blind controlCT
0Button 2 [Long Press 2]Value --> 1-byte scene learn1 Byte18.1 scene controlCT
0Button 2 [Long Press 2]Value --> 3-byte color3 Bytes232.600 RGB value 3x(0..255)CT
0Button 2 [Long Press Repeat 2]Value --> 1-bit1 Bit1.1 switchCT
0Button 2 [Long Press Repeat 2]Value --> 1-bit HVAC control mode1 Bit1.100 cooling/heatingCT
0Button 2 [Long Press Repeat 2]Value <-> 1-bit toggle1 Bit1.1 switchCWT
0Button 2 [Long Press Repeat 2]Value --> 1-byte unsigned1 Byte5.10 counter pulses (0..255)CT
0Button 2 [Long Press Repeat 2]Value --> 1-byte signed1 Byte6.10 counter pulses (-128..127)CT
0Button 2 [Long Press Repeat 2]Value --> 1-byte HVAC operating mode1 Byte20.102 HVAC modeCT
0Button 2 [Long Press Repeat 2]Value --> 1-byte percentage1 Byte5.1 percentage (0..100%)CT
0Button 2 [Long Press Repeat 2]Value --> 1-byte scene activate1 Byte18.1 scene controlCT
0Button 2 [Long Press Repeat 2]Value --> 2-byte unsigned2 Bytes7.1 pulsesCT
0Button 2 [Long Press Repeat 2]Value --> 2-byte signed2 Bytes8.1 pulses differenceCT
0Button 2 [Long Press Repeat 2]Value --> 2-byte float2 Bytes9.1 temperature (°C)CT
0Button 2 [Long Press Repeat 2]Value --> 4-byte unsigned4 Bytes12.1 counter pulses (unsigned)CT
0Button 2 [Long Press Repeat 2]Value --> 4-byte signed4 Bytes13.1 counter pulses (signed)CT
0Button 2 [Long Press Repeat 2]Value --> 4-byte float4 Bytes14.5 amplitudeCT
0Button 2 [Long Press Repeat 2]Value <-> 1-byte counter/sequence1 Byte5.10 counter pulses (0..255)CWT
0Button 2 [Long Press Repeat 2]Value --> 2-bit priority control2 Bit2.1 switch controlCT
0Button 2 [Long Press Repeat 2]Value --> 4-bit dimming control4 Bit3.7 dimming controlCT
0Button 2 [Long Press Repeat 2]Value --> 4-bit blind control4 Bit3.8 blind controlCT
0Button 2 [Long Press Repeat 2]Value --> 1-byte scene learn1 Byte18.1 scene controlCT
0Button 2 [Long Press Repeat 2]Value --> 3-byte color3 Bytes232.600 RGB value 3x(0..255)CT
0Button 2 [Long Press Release 2]Value --> 1-bit1 Bit1.1 switchCT
0Button 2 [Long Press Release 2]Value --> 1-bit HVAC control mode1 Bit1.100 cooling/heatingCT
0Button 2 [Long Press Release 2]Value <-> 1-bit toggle1 Bit1.1 switchCWT
0Button 2 [Long Press Release 2]Value --> 1-byte unsigned1 Byte5.10 counter pulses (0..255)CT
0Button 2 [Long Press Release 2]Value --> 1-byte signed1 Byte6.10 counter pulses (-128..127)CT
0Button 2 [Long Press Release 2]Value --> 1-byte HVAC operating mode1 Byte20.102 HVAC modeCT
0Button 2 [Long Press Release 2]Value --> 1-byte percentage1 Byte5.1 percentage (0..100%)CT
0Button 2 [Long Press Release 2]Value --> 1-byte scene activate1 Byte18.1 scene controlCT
0Button 2 [Long Press Release 2]Value --> 2-byte unsigned2 Bytes7.1 pulsesCT
0Button 2 [Long Press Release 2]Value --> 2-byte signed2 Bytes8.1 pulses differenceCT
0Button 2 [Long Press Release 2]Value --> 2-byte float2 Bytes9.1 temperature (°C)CT
0Button 2 [Long Press Release 2]Value --> 4-byte unsigned4 Bytes12.1 counter pulses (unsigned)CT
0Button 2 [Long Press Release 2]Value --> 4-byte signed4 Bytes13.1 counter pulses (signed)CT
0Button 2 [Long Press Release 2]Value --> 4-byte float4 Bytes14.5 amplitudeCT
0Button 2 [Long Press Release 2]Value <-> 1-byte counter/sequence1 Byte5.10 counter pulses (0..255)CWT
0Button 2 [Long Press Release 2]Value --> 2-bit priority control2 Bit2.1 switch controlCT
0Button 2 [Long Press Release 2]Value --> 4-bit dimming control4 Bit3.7 dimming controlCT
0Button 2 [Long Press Release 2]Value --> 4-bit blind control4 Bit3.8 blind controlCT
0Button 2 [Long Press Release 2]Value --> 1-byte scene learn1 Byte18.1 scene controlCT
0Button 2 [Long Press Release 2]Value --> 3-byte color3 Bytes232.600 RGB value 3x(0..255)CT
0Button 2 [Short Press 3]Value --> 1-bit1 Bit1.1 switchCT
0Button 2 [Short Press 3]Value --> 1-bit HVAC control mode1 Bit1.100 cooling/heatingCT
0Button 2 [Short Press 3]Value <-> 1-bit toggle1 Bit1.1 switchCWT
0Button 2 [Short Press 3]Value --> 1-byte unsigned1 Byte5.10 counter pulses (0..255)CT
0Button 2 [Short Press 3]Value --> 1-byte signed1 Byte6.10 counter pulses (-128..127)CT
0Button 2 [Short Press 3]Value --> 1-byte HVAC operating mode1 Byte20.102 HVAC modeCT
0Button 2 [Short Press 3]Value --> 1-byte percentage1 Byte5.1 percentage (0..100%)CT
0Button 2 [Short Press 3]Value --> 1-byte scene activate1 Byte18.1 scene controlCT
0Button 2 [Short Press 3]Value --> 2-byte unsigned2 Bytes7.1 pulsesCT
0Button 2 [Short Press 3]Value --> 2-byte signed2 Bytes8.1 pulses differenceCT
0Button 2 [Short Press 3]Value --> 2-byte float2 Bytes9.1 temperature (°C)CT
0Button 2 [Short Press 3]Value --> 4-byte unsigned4 Bytes12.1 counter pulses (unsigned)CT
0Button 2 [Short Press 3]Value --> 4-byte signed4 Bytes13.1 counter pulses (signed)CT
0Button 2 [Short Press 3]Value --> 4-byte float4 Bytes14.5 amplitudeCT
0Button 2 [Short Press 3]Value <-> 1-byte counter/sequence1 Byte5.10 counter pulses (0..255)CWT
0Button 2 [Short Press 3]Value --> 2-bit priority control2 Bit2.1 switch controlCT
0Button 2 [Short Press 3]Value --> 4-bit dimming control4 Bit3.7 dimming controlCT
0Button 2 [Short Press 3]Value --> 4-bit blind control4 Bit3.8 blind controlCT
0Button 2 [Short Press 3]Value --> 1-byte scene learn1 Byte18.1 scene controlCT
0Button 2 [Short Press 3]Value --> 3-byte color3 Bytes232.600 RGB value 3x(0..255)CT
0Button 2 [Double Press 3]Value --> 1-bit1 Bit1.1 switchCT
0Button 2 [Double Press 3]Value --> 1-bit HVAC control mode1 Bit1.100 cooling/heatingCT
0Button 2 [Double Press 3]Value <-> 1-bit toggle1 Bit1.1 switchCWT
0Button 2 [Double Press 3]Value --> 1-byte unsigned1 Byte5.10 counter pulses (0..255)CT
0Button 2 [Double Press 3]Value --> 1-byte signed1 Byte6.10 counter pulses (-128..127)CT
0Button 2 [Double Press 3]Value --> 1-byte HVAC operating mode1 Byte20.102 HVAC modeCT
0Button 2 [Double Press 3]Value --> 1-byte percentage1 Byte5.1 percentage (0..100%)CT
0Button 2 [Double Press 3]Value --> 1-byte scene activate1 Byte18.1 scene controlCT
0Button 2 [Double Press 3]Value --> 2-byte unsigned2 Bytes7.1 pulsesCT
0Button 2 [Double Press 3]Value --> 2-byte signed2 Bytes8.1 pulses differenceCT
0Button 2 [Double Press 3]Value --> 2-byte float2 Bytes9.1 temperature (°C)CT
0Button 2 [Double Press 3]Value --> 4-byte unsigned4 Bytes12.1 counter pulses (unsigned)CT
0Button 2 [Double Press 3]Value --> 4-byte signed4 Bytes13.1 counter pulses (signed)CT
0Button 2 [Double Press 3]Value --> 4-byte float4 Bytes14.5 amplitudeCT
0Button 2 [Double Press 3]Value <-> 1-byte counter/sequence1 Byte5.10 counter pulses (0..255)CWT
0Button 2 [Double Press 3]Value --> 2-bit priority control2 Bit2.1 switch controlCT
0Button 2 [Double Press 3]Value --> 4-bit dimming control4 Bit3.7 dimming controlCT
0Button 2 [Double Press 3]Value --> 4-bit blind control4 Bit3.8 blind controlCT
0Button 2 [Double Press 3]Value --> 1-byte scene learn1 Byte18.1 scene controlCT
0Button 2 [Double Press 3]Value --> 3-byte color3 Bytes232.600 RGB value 3x(0..255)CT
0Button 2 [Triple Press 3]Value --> 1-bit1 Bit1.1 switchCT
0Button 2 [Triple Press 3]Value --> 1-bit HVAC control mode1 Bit1.100 cooling/heatingCT
0Button 2 [Triple Press 3]Value <-> 1-bit toggle1 Bit1.1 switchCWT
0Button 2 [Triple Press 3]Value --> 1-byte unsigned1 Byte5.10 counter pulses (0..255)CT
0Button 2 [Triple Press 3]Value --> 1-byte signed1 Byte6.10 counter pulses (-128..127)CT
0Button 2 [Triple Press 3]Value --> 1-byte HVAC operating mode1 Byte20.102 HVAC modeCT
0Button 2 [Triple Press 3]Value --> 1-byte percentage1 Byte5.1 percentage (0..100%)CT
0Button 2 [Triple Press 3]Value --> 1-byte scene activate1 Byte18.1 scene controlCT
0Button 2 [Triple Press 3]Value --> 2-byte unsigned2 Bytes7.1 pulsesCT
0Button 2 [Triple Press 3]Value --> 2-byte signed2 Bytes8.1 pulses differenceCT
0Button 2 [Triple Press 3]Value --> 2-byte float2 Bytes9.1 temperature (°C)CT
0Button 2 [Triple Press 3]Value --> 4-byte unsigned4 Bytes12.1 counter pulses (unsigned)CT
0Button 2 [Triple Press 3]Value --> 4-byte signed4 Bytes13.1 counter pulses (signed)CT
0Button 2 [Triple Press 3]Value --> 4-byte float4 Bytes14.5 amplitudeCT
0Button 2 [Triple Press 3]Value <-> 1-byte counter/sequence1 Byte5.10 counter pulses (0..255)CWT
0Button 2 [Triple Press 3]Value --> 2-bit priority control2 Bit2.1 switch controlCT
0Button 2 [Triple Press 3]Value --> 4-bit dimming control4 Bit3.7 dimming controlCT
0Button 2 [Triple Press 3]Value --> 4-bit blind control4 Bit3.8 blind controlCT
0Button 2 [Triple Press 3]Value --> 1-byte scene learn1 Byte18.1 scene controlCT
0Button 2 [Triple Press 3]Value --> 3-byte color3 Bytes232.600 RGB value 3x(0..255)CT
0Button 2 [Long Press 3]Value --> 1-bit1 Bit1.1 switchCT
0Button 2 [Long Press 3]Value --> 1-bit HVAC control mode1 Bit1.100 cooling/heatingCT
0Button 2 [Long Press 3]Value <-> 1-bit toggle1 Bit1.1 switchCWT
0Button 2 [Long Press 3]Value --> 1-byte unsigned1 Byte5.10 counter pulses (0..255)CT
0Button 2 [Long Press 3]Value --> 1-byte signed1 Byte6.10 counter pulses (-128..127)CT
0Button 2 [Long Press 3]Value --> 1-byte HVAC operating mode1 Byte20.102 HVAC modeCT
0Button 2 [Long Press 3]Value --> 1-byte percentage1 Byte5.1 percentage (0..100%)CT
0Button 2 [Long Press 3]Value --> 1-byte scene activate1 Byte18.1 scene controlCT
0Button 2 [Long Press 3]Value --> 2-byte unsigned2 Bytes7.1 pulsesCT
0Button 2 [Long Press 3]Value --> 2-byte signed2 Bytes8.1 pulses differenceCT
0Button 2 [Long Press 3]Value --> 2-byte float2 Bytes9.1 temperature (°C)CT
0Button 2 [Long Press 3]Value --> 4-byte unsigned4 Bytes12.1 counter pulses (unsigned)CT
0Button 2 [Long Press 3]Value --> 4-byte signed4 Bytes13.1 counter pulses (signed)CT
0Button 2 [Long Press 3]Value --> 4-byte float4 Bytes14.5 amplitudeCT
0Button 2 [Long Press 3]Value <-> 1-byte counter/sequence1 Byte5.10 counter pulses (0..255)CWT
0Button 2 [Long Press 3]Value --> 2-bit priority control2 Bit2.1 switch controlCT
0Button 2 [Long Press 3]Value --> 4-bit dimming control4 Bit3.7 dimming controlCT
0Button 2 [Long Press 3]Value --> 4-bit blind control4 Bit3.8 blind controlCT
0Button 2 [Long Press 3]Value --> 1-byte scene learn1 Byte18.1 scene controlCT
0Button 2 [Long Press 3]Value --> 3-byte color3 Bytes232.600 RGB value 3x(0..255)CT
0Button 2 [Long Press Repeat 3]Value --> 1-bit1 Bit1.1 switchCT
0Button 2 [Long Press Repeat 3]Value --> 1-bit HVAC control mode1 Bit1.100 cooling/heatingCT
0Button 2 [Long Press Repeat 3]Value <-> 1-bit toggle1 Bit1.1 switchCWT
0Button 2 [Long Press Repeat 3]Value --> 1-byte unsigned1 Byte5.10 counter pulses (0..255)CT
0Button 2 [Long Press Repeat 3]Value --> 1-byte signed1 Byte6.10 counter pulses (-128..127)CT
0Button 2 [Long Press Repeat 3]Value --> 1-byte HVAC operating mode1 Byte20.102 HVAC modeCT
0Button 2 [Long Press Repeat 3]Value --> 1-byte percentage1 Byte5.1 percentage (0..100%)CT
0Button 2 [Long Press Repeat 3]Value --> 1-byte scene activate1 Byte18.1 scene controlCT
0Button 2 [Long Press Repeat 3]Value --> 2-byte unsigned2 Bytes7.1 pulsesCT
0Button 2 [Long Press Repeat 3]Value --> 2-byte signed2 Bytes8.1 pulses differenceCT
0Button 2 [Long Press Repeat 3]Value --> 2-byte float2 Bytes9.1 temperature (°C)CT
0Button 2 [Long Press Repeat 3]Value --> 4-byte unsigned4 Bytes12.1 counter pulses (unsigned)CT
0Button 2 [Long Press Repeat 3]Value --> 4-byte signed4 Bytes13.1 counter pulses (signed)CT
0Button 2 [Long Press Repeat 3]Value --> 4-byte float4 Bytes14.5 amplitudeCT
0Button 2 [Long Press Repeat 3]Value <-> 1-byte counter/sequence1 Byte5.10 counter pulses (0..255)CWT
0Button 2 [Long Press Repeat 3]Value --> 2-bit priority control2 Bit2.1 switch controlCT
0Button 2 [Long Press Repeat 3]Value --> 4-bit dimming control4 Bit3.7 dimming controlCT
0Button 2 [Long Press Repeat 3]Value --> 4-bit blind control4 Bit3.8 blind controlCT
0Button 2 [Long Press Repeat 3]Value --> 1-byte scene learn1 Byte18.1 scene controlCT
0Button 2 [Long Press Repeat 3]Value --> 3-byte color3 Bytes232.600 RGB value 3x(0..255)CT
0Button 2 [Long Press Release 3]Value --> 1-bit1 Bit1.1 switchCT
0Button 2 [Long Press Release 3]Value --> 1-bit HVAC control mode1 Bit1.100 cooling/heatingCT
0Button 2 [Long Press Release 3]Value <-> 1-bit toggle1 Bit1.1 switchCWT
0Button 2 [Long Press Release 3]Value --> 1-byte unsigned1 Byte5.10 counter pulses (0..255)CT
0Button 2 [Long Press Release 3]Value --> 1-byte signed1 Byte6.10 counter pulses (-128..127)CT
0Button 2 [Long Press Release 3]Value --> 1-byte HVAC operating mode1 Byte20.102 HVAC modeCT
0Button 2 [Long Press Release 3]Value --> 1-byte percentage1 Byte5.1 percentage (0..100%)CT
0Button 2 [Long Press Release 3]Value --> 1-byte scene activate1 Byte18.1 scene controlCT
0Button 2 [Long Press Release 3]Value --> 2-byte unsigned2 Bytes7.1 pulsesCT
0Button 2 [Long Press Release 3]Value --> 2-byte signed2 Bytes8.1 pulses differenceCT
0Button 2 [Long Press Release 3]Value --> 2-byte float2 Bytes9.1 temperature (°C)CT
0Button 2 [Long Press Release 3]Value --> 4-byte unsigned4 Bytes12.1 counter pulses (unsigned)CT
0Button 2 [Long Press Release 3]Value --> 4-byte signed4 Bytes13.1 counter pulses (signed)CT
0Button 2 [Long Press Release 3]Value --> 4-byte float4 Bytes14.5 amplitudeCT
0Button 2 [Long Press Release 3]Value <-> 1-byte counter/sequence1 Byte5.10 counter pulses (0..255)CWT
0Button 2 [Long Press Release 3]Value --> 2-bit priority control2 Bit2.1 switch controlCT
0Button 2 [Long Press Release 3]Value --> 4-bit dimming control4 Bit3.7 dimming controlCT
0Button 2 [Long Press Release 3]Value --> 4-bit blind control4 Bit3.8 blind controlCT
0Button 2 [Long Press Release 3]Value --> 1-byte scene learn1 Byte18.1 scene controlCT
0Button 2 [Long Press Release 3]Value --> 3-byte color3 Bytes232.600 RGB value 3x(0..255)CT
0Button 2 [Short Press 4]Value --> 1-bit1 Bit1.1 switchCT
0Button 2 [Short Press 4]Value --> 1-bit HVAC control mode1 Bit1.100 cooling/heatingCT
0Button 2 [Short Press 4]Value <-> 1-bit toggle1 Bit1.1 switchCWT
0Button 2 [Short Press 4]Value --> 1-byte unsigned1 Byte5.10 counter pulses (0..255)CT
0Button 2 [Short Press 4]Value --> 1-byte signed1 Byte6.10 counter pulses (-128..127)CT
0Button 2 [Short Press 4]Value --> 1-byte HVAC operating mode1 Byte20.102 HVAC modeCT
0Button 2 [Short Press 4]Value --> 1-byte percentage1 Byte5.1 percentage (0..100%)CT
0Button 2 [Short Press 4]Value --> 1-byte scene activate1 Byte18.1 scene controlCT
0Button 2 [Short Press 4]Value --> 2-byte unsigned2 Bytes7.1 pulsesCT
0Button 2 [Short Press 4]Value --> 2-byte signed2 Bytes8.1 pulses differenceCT
0Button 2 [Short Press 4]Value --> 2-byte float2 Bytes9.1 temperature (°C)CT
0Button 2 [Short Press 4]Value --> 4-byte unsigned4 Bytes12.1 counter pulses (unsigned)CT
0Button 2 [Short Press 4]Value --> 4-byte signed4 Bytes13.1 counter pulses (signed)CT
0Button 2 [Short Press 4]Value --> 4-byte float4 Bytes14.5 amplitudeCT
0Button 2 [Short Press 4]Value <-> 1-byte counter/sequence1 Byte5.10 counter pulses (0..255)CWT
0Button 2 [Short Press 4]Value --> 2-bit priority control2 Bit2.1 switch controlCT
0Button 2 [Short Press 4]Value --> 4-bit dimming control4 Bit3.7 dimming controlCT
0Button 2 [Short Press 4]Value --> 4-bit blind control4 Bit3.8 blind controlCT
0Button 2 [Short Press 4]Value --> 1-byte scene learn1 Byte18.1 scene controlCT
0Button 2 [Short Press 4]Value --> 3-byte color3 Bytes232.600 RGB value 3x(0..255)CT
0Button 2 [Double Press 4]Value --> 1-bit1 Bit1.1 switchCT
0Button 2 [Double Press 4]Value --> 1-bit HVAC control mode1 Bit1.100 cooling/heatingCT
0Button 2 [Double Press 4]Value <-> 1-bit toggle1 Bit1.1 switchCWT
0Button 2 [Double Press 4]Value --> 1-byte unsigned1 Byte5.10 counter pulses (0..255)CT
0Button 2 [Double Press 4]Value --> 1-byte signed1 Byte6.10 counter pulses (-128..127)CT
0Button 2 [Double Press 4]Value --> 1-byte HVAC operating mode1 Byte20.102 HVAC modeCT
0Button 2 [Double Press 4]Value --> 1-byte percentage1 Byte5.1 percentage (0..100%)CT
0Button 2 [Double Press 4]Value --> 1-byte scene activate1 Byte18.1 scene controlCT
0Button 2 [Double Press 4]Value --> 2-byte unsigned2 Bytes7.1 pulsesCT
0Button 2 [Double Press 4]Value --> 2-byte signed2 Bytes8.1 pulses differenceCT
0Button 2 [Double Press 4]Value --> 2-byte float2 Bytes9.1 temperature (°C)CT
0Button 2 [Double Press 4]Value --> 4-byte unsigned4 Bytes12.1 counter pulses (unsigned)CT
0Button 2 [Double Press 4]Value --> 4-byte signed4 Bytes13.1 counter pulses (signed)CT
0Button 2 [Double Press 4]Value --> 4-byte float4 Bytes14.5 amplitudeCT
0Button 2 [Double Press 4]Value <-> 1-byte counter/sequence1 Byte5.10 counter pulses (0..255)CWT
0Button 2 [Double Press 4]Value --> 2-bit priority control2 Bit2.1 switch controlCT
0Button 2 [Double Press 4]Value --> 4-bit dimming control4 Bit3.7 dimming controlCT
0Button 2 [Double Press 4]Value --> 4-bit blind control4 Bit3.8 blind controlCT
0Button 2 [Double Press 4]Value --> 1-byte scene learn1 Byte18.1 scene controlCT
0Button 2 [Double Press 4]Value --> 3-byte color3 Bytes232.600 RGB value 3x(0..255)CT
0Button 2 [Triple Press 4]Value --> 1-bit1 Bit1.1 switchCT
0Button 2 [Triple Press 4]Value --> 1-bit HVAC control mode1 Bit1.100 cooling/heatingCT
0Button 2 [Triple Press 4]Value <-> 1-bit toggle1 Bit1.1 switchCWT
0Button 2 [Triple Press 4]Value --> 1-byte unsigned1 Byte5.10 counter pulses (0..255)CT
0Button 2 [Triple Press 4]Value --> 1-byte signed1 Byte6.10 counter pulses (-128..127)CT
0Button 2 [Triple Press 4]Value --> 1-byte HVAC operating mode1 Byte20.102 HVAC modeCT
0Button 2 [Triple Press 4]Value --> 1-byte percentage1 Byte5.1 percentage (0..100%)CT
0Button 2 [Triple Press 4]Value --> 1-byte scene activate1 Byte18.1 scene controlCT
0Button 2 [Triple Press 4]Value --> 2-byte unsigned2 Bytes7.1 pulsesCT
0Button 2 [Triple Press 4]Value --> 2-byte signed2 Bytes8.1 pulses differenceCT
0Button 2 [Triple Press 4]Value --> 2-byte float2 Bytes9.1 temperature (°C)CT
0Button 2 [Triple Press 4]Value --> 4-byte unsigned4 Bytes12.1 counter pulses (unsigned)CT
0Button 2 [Triple Press 4]Value --> 4-byte signed4 Bytes13.1 counter pulses (signed)CT
0Button 2 [Triple Press 4]Value --> 4-byte float4 Bytes14.5 amplitudeCT
0Button 2 [Triple Press 4]Value <-> 1-byte counter/sequence1 Byte5.10 counter pulses (0..255)CWT
0Button 2 [Triple Press 4]Value --> 2-bit priority control2 Bit2.1 switch controlCT
0Button 2 [Triple Press 4]Value --> 4-bit dimming control4 Bit3.7 dimming controlCT
0Button 2 [Triple Press 4]Value --> 4-bit blind control4 Bit3.8 blind controlCT
0Button 2 [Triple Press 4]Value --> 1-byte scene learn1 Byte18.1 scene controlCT
0Button 2 [Triple Press 4]Value --> 3-byte color3 Bytes232.600 RGB value 3x(0..255)CT
0Button 2 [Long Press 4]Value --> 1-bit1 Bit1.1 switchCT
0Button 2 [Long Press 4]Value --> 1-bit HVAC control mode1 Bit1.100 cooling/heatingCT
0Button 2 [Long Press 4]Value <-> 1-bit toggle1 Bit1.1 switchCWT
0Button 2 [Long Press 4]Value --> 1-byte unsigned1 Byte5.10 counter pulses (0..255)CT
0Button 2 [Long Press 4]Value --> 1-byte signed1 Byte6.10 counter pulses (-128..127)CT
0Button 2 [Long Press 4]Value --> 1-byte HVAC operating mode1 Byte20.102 HVAC modeCT
0Button 2 [Long Press 4]Value --> 1-byte percentage1 Byte5.1 percentage (0..100%)CT
0Button 2 [Long Press 4]Value --> 1-byte scene activate1 Byte18.1 scene controlCT
0Button 2 [Long Press 4]Value --> 2-byte unsigned2 Bytes7.1 pulsesCT
0Button 2 [Long Press 4]Value --> 2-byte signed2 Bytes8.1 pulses differenceCT
0Button 2 [Long Press 4]Value --> 2-byte float2 Bytes9.1 temperature (°C)CT
0Button 2 [Long Press 4]Value --> 4-byte unsigned4 Bytes12.1 counter pulses (unsigned)CT
0Button 2 [Long Press 4]Value --> 4-byte signed4 Bytes13.1 counter pulses (signed)CT
0Button 2 [Long Press 4]Value --> 4-byte float4 Bytes14.5 amplitudeCT
0Button 2 [Long Press 4]Value <-> 1-byte counter/sequence1 Byte5.10 counter pulses (0..255)CWT
0Button 2 [Long Press 4]Value --> 2-bit priority control2 Bit2.1 switch controlCT
0Button 2 [Long Press 4]Value --> 4-bit dimming control4 Bit3.7 dimming controlCT
0Button 2 [Long Press 4]Value --> 4-bit blind control4 Bit3.8 blind controlCT
0Button 2 [Long Press 4]Value --> 1-byte scene learn1 Byte18.1 scene controlCT
0Button 2 [Long Press 4]Value --> 3-byte color3 Bytes232.600 RGB value 3x(0..255)CT
0Button 2 [Long Press Repeat 4]Value --> 1-bit1 Bit1.1 switchCT
0Button 2 [Long Press Repeat 4]Value --> 1-bit HVAC control mode1 Bit1.100 cooling/heatingCT
0Button 2 [Long Press Repeat 4]Value <-> 1-bit toggle1 Bit1.1 switchCWT
0Button 2 [Long Press Repeat 4]Value --> 1-byte unsigned1 Byte5.10 counter pulses (0..255)CT
0Button 2 [Long Press Repeat 4]Value --> 1-byte signed1 Byte6.10 counter pulses (-128..127)CT
0Button 2 [Long Press Repeat 4]Value --> 1-byte HVAC operating mode1 Byte20.102 HVAC modeCT
0Button 2 [Long Press Repeat 4]Value --> 1-byte percentage1 Byte5.1 percentage (0..100%)CT
0Button 2 [Long Press Repeat 4]Value --> 1-byte scene activate1 Byte18.1 scene controlCT
0Button 2 [Long Press Repeat 4]Value --> 2-byte unsigned2 Bytes7.1 pulsesCT
0Button 2 [Long Press Repeat 4]Value --> 2-byte signed2 Bytes8.1 pulses differenceCT
0Button 2 [Long Press Repeat 4]Value --> 2-byte float2 Bytes9.1 temperature (°C)CT
0Button 2 [Long Press Repeat 4]Value --> 4-byte unsigned4 Bytes12.1 counter pulses (unsigned)CT
0Button 2 [Long Press Repeat 4]Value --> 4-byte signed4 Bytes13.1 counter pulses (signed)CT
0Button 2 [Long Press Repeat 4]Value --> 4-byte float4 Bytes14.5 amplitudeCT
0Button 2 [Long Press Repeat 4]Value <-> 1-byte counter/sequence1 Byte5.10 counter pulses (0..255)CWT
0Button 2 [Long Press Repeat 4]Value --> 2-bit priority control2 Bit2.1 switch controlCT
0Button 2 [Long Press Repeat 4]Value --> 4-bit dimming control4 Bit3.7 dimming controlCT
0Button 2 [Long Press Repeat 4]Value --> 4-bit blind control4 Bit3.8 blind controlCT
0Button 2 [Long Press Repeat 4]Value --> 1-byte scene learn1 Byte18.1 scene controlCT

First 1000 of 6254 group objects shown. Download the .knxprod for the full list.

Parameters (287)
ParameterTypeDefault
In Operation TelegramunsignedInt 0…10
In Operation Valuelist1
In Operation Sending IntervalunsignedInt 10…65535300
Telegram LimiterunsignedInt 0…10
Telegram Limit Period Durationlist50 ms
Maximum Telegram Count In PeriodunsignedInt 1…2551
Switch Configurationlist1 Button
Telegram Transmission Delay (after KNX bus recovery)unsignedInt 1…2551
Dark Levellist1 (1.5%) = Min
Bright Levellist7 (100%) = Max
Status LED "Operation Indication" Durationlist0.75 s
Ambient Light SensorunsignedInt 0…10
Custom Levellist1 (1.5%) = Min
Ambient Light DimunsignedInt 0…10
Proximity DimunsignedInt 0…10
Ambient Light DetectionunsignedInt 0…10
SourcelistObject (External)
Send Day/Night StatusunsignedInt 0…10
DPT Day/Night Objectlist0 = Day; 1 = Night [DPT_DayNight]
SendlistOn Change
Diagnostic ModeunsignedInt 0…10
Low Pass Filter Levellist4
ThresholdunsignedInt 1…2558
HyteresisunsignedInt 2…2552
Cyclic Sending IntervalunsignedInt 10…65535300
Day/Night SourcelistObject (External)
AdvancedunsignedInt 0…10
Proximity SensorunsignedInt 0…10
Proximity DetectionunsignedInt 0…10
Send Proximity StatusunsignedInt 0…10
Proximity SourcelistButton Press
Proximity Generator IDlist1
Presence Transmit Repeat IntervalunsignedInt 0…2550
Object Monitoring TimeoutunsignedInt 0…2550
Presence TimeoutunsignedInt 1…25510
Sensor SensitivitylistMedium
Proximity ObjectlistSingle Generator
Firmware Versiontext-----
Day/Night State after KNX Bus RecoverylistReset
Logic BlockslistNone
ets_data_struct_idunsignedInt 0…2551
virt_button_countunsignedInt 1…121
Ambient Light Sensortext-----
Proximity Sensortext-----
Uptimetext-----
sensor.als.use_default_sensor_settingsunsignedInt 0…10
virt_builtin_sensors_enabledlistFalse
Touch Feedback Max Duration (0 to wait until touch release)unsignedInt 0…2550
Touch FeedbackunsignedInt 0…10
Custom Color ObjectunsignedInt 0…10
Value after KNX bus recoverylistKeep
Exit feedback immediately on status LED updateunsignedInt 0…10
Custom ColorlistRed
Object DPTlistEnumerated
Object FeedbacklistNone
Feedback ColorlistRed
Thermocolor in Custom ColorslistNo
Custom Level ObjectunsignedInt 0…10
Humidity Sensortext-----
Temperature Sensortext-----
Humidity SensorunsignedInt 0…10
Alarm ObjectsunsignedInt 0…10
Send Humidity on AlarmunsignedInt 0…10
Send HumiditylistCyclic and Change
Minimum ChangeunsignedInt 1…1001
Alarm Exit HysteresisunsignedInt 0…1001
Low Humidity AlarmunsignedInt 0…10030
High Humidity AlarmunsignedInt 0…10060
Alarm DelayunsignedInt 0…655350
Cyclic Sending IntervalunsignedInt 0…6553560
Temperature SensorunsignedInt 0…10
Temperature UnitlistCelsius (°C)
OffsetsignedInt -128…1270
Send TemperaturelistCyclic and Change
Minimum ChangeunsignedInt 1…2551
Hardware Typetext-----
Dew Point Sensortext-----
Dew Point SensorunsignedInt 0…10
Alarm ObjectunsignedInt 0…10
Send Dew Point Temperature on AlarmunsignedInt 0…10
Send Dew Point TemperaturelistCyclic and Change
Dew Point Temperature UnitlistCelsius (°C)
Send Alarm CycliclistNever
Alarm Exit HysteresisunsignedInt 0…25510
Alarm ThresholdunsignedInt 0…25520
Cyclic Sending IntervalunsignedInt 1…6553560
Send Temperature on AlarmunsignedInt 0…10
Alarm Exit HysteresisunsignedInt 1…2555
Low Temperature AlarmsignedInt -128…1275
High Temperature AlarmunsignedInt 0…25540
Low Temperature AlarmsignedInt -128…12741
High Temperature AlarmunsignedInt 0…25595
I/O Configlist15 Input / 1 Output
Nametext
Data typelist1-bit
PreprocesslistPassthrough
greater than or equal tounsignedInt 0…2550
less than or equal tounsignedInt 0…255255
match 1unsignedInt 0…2550
match 2unsignedInt 0…2551
maskunsignedInt 1…2551
False if <=unsignedInt 0…255100
True if >=unsignedInt 0…255128
Initial statelistFalse
State after KNX bus recoverylistInitial
RegisterunsignedInt 0…10
IN1 {{0:}}unsignedInt 0…10
IN2 {{0:}}unsignedInt 0…10
IN3 {{0:}}unsignedInt 0…10
IN4 {{0:}}unsignedInt 0…10
IN5 {{0:}}unsignedInt 0…10
IN6 {{0:}}unsignedInt 0…10
IN7 {{0:}}unsignedInt 0…10
IN8 {{0:}}unsignedInt 0…10
IN9 {{0:}}unsignedInt 0…10
IN10 {{0:}}unsignedInt 0…10
IN11 {{0:}}unsignedInt 0…10
IN12 {{0:}}unsignedInt 0…10
IN13 {{0:}}unsignedInt 0…10
IN14 {{0:}}unsignedInt 0…10
IN15 {{0:}}unsignedInt 0…10
REG OUT2 {{0:}}unsignedInt 0…10
REG OUT3 {{0:}}unsignedInt 0…10
REG OUT4 {{0:}}unsignedInt 0…10
REG OUT5 {{0:}}unsignedInt 0…10
REG OUT6 {{0:}}unsignedInt 0…10
REG OUT7 {{0:}}unsignedInt 0…10
REG OUT8 {{0:}}unsignedInt 0…10
REG OUT9 {{0:}}unsignedInt 0…10
REG OUT10 {{0:}}unsignedInt 0…10
REG OUT11 {{0:}}unsignedInt 0…10
REG OUT12 {{0:}}unsignedInt 0…10
REG OUT13 {{0:}}unsignedInt 0…10
REG OUT14 {{0:}}unsignedInt 0…10
REG OUT15 {{0:}}unsignedInt 0…10
STATEunsignedInt 0…10
Descriptiontext
OperationlistPassthrough (unary)
Triggerlistoperand update
Sending blocked whenlistIN1
Send pending telegram after unblockingunsignedInt 0…10
Send value when expression islistTrue or False
False valuelist0
False valueunsignedInt 0…2550
False valuelist00b (No Priority, False)
True valuelist1
True valueunsignedInt 0…2551
True valuelist01b (No Priority, True)
Send only on changeunsignedInt 0…10
Send initial state after KNX bus recoveryunsignedInt 0…10
Timerlistnone
active when expression islistTrue or False
active when expression islistTrue
REG OUT1 {{0:}}unsignedInt 0…10
Cleaning ModeunsignedInt 0…10
Enter Cleaning Mode withlistObject only
DPT Cleaning Mode Objectlist0 = Disable; 1 = Enable [DPT_Enable]
LED FeedbacklistFlashing
ColorlistRed
TimeoutunsignedInt 0…655350
Long Press ButtonlistButton 1
Long Press DurationunsignedInt 5…10050
Exit Cleaning Mode by Long PressinglistSame Button
Exit Cleaning Mode by Long PressinglistNo
Presence sensorunsignedInt 0…10
Presence sizetext
Detector modelistMaster
Number of slaveslistNo Slave
Detector sensitivitylistHigh
byPresenceSwitchOnDelayunsignedInt 0…2550
Min number of movementsunsignedInt 0…2551
Type of outputlist1 Bit
Output object sends atlistSwitch On/Off
Cyclical repeating time[sec]unsignedInt 10…6553530
Value for switch offlistOff
Value for switch offunsignedInt 0…1000
Value for switch offunsignedInt 0…2550
Value for switch offlistscene 1
Value for switch offunsignedInt 0…655350
Value for switch offlisteco
Sending value for switch off cycliclistNo
Value for switch onlistOn
Value for switch onunsignedInt 0…100100
Value for switch onunsignedInt 0…255255
Value for switch onlistscene 1
Value for switch onunsignedInt 0…6553565535
Value for switch onlistcomfort
Sending value for switch on cycliclistNo
Stay on time[sec]time10
Break in presence detection[sec]unsignedInt 0…2552
Stay on time can be changed by buslistNo
Min cycle time for sendlist30 sec
Disable presence outputlistNo
Behaviour disable presencelistdetector sends no telegram
Behaviour enable presencelistdetector sends switch off
Cyclical repeating countunsignedInt 0…2550
Overwrite Stay on time parameter for ets downloadlistNo
pv_CyclicSendinglistYes
pv_OutputOnOff_0listYes
pv_OutputOnOff_1listYes
pv_OutputPercent_0listYes
pv_OutputPercent_1listYes
pv_OutputByte_0listYes
pv_OutputBytet_1listYes
pv_OutputScene_0listYes
pv_OutputScene_1listYes
pv_OutputDecimal_0listYes
pv_OutputDecimal_1listYes
pv_OutputRTC_0listYes
pv_OutputRTC_1listYes
Sending value for switch off cycliclistYes
pv_SendValuecyc_1listYes
Custom sensitivity valueunsignedInt 11…2511
On BrightnesslistBright
On ColorlistRed
Off BrightnesslistOff
Off ColorlistRed
Button Lock ObjectunsignedInt 0…10
DPT Lock Objectlist0 = Unlock; 1 = Lock
Lock State after KNX Bus RecoverylistKeep
LED Function when LockedlistActive
Disabled BrightnesslistOff
Disabled ColorlistRed
Button FunctionlistNo Function
Command on PresslistToggle
Command on ReleaselistNo Command
Function of LEDlistStatus Indication
Separate Switch Status ObjectunsignedInt 0…10
Dim OperationlistDarker/Brighter (Short Press Toggle)
Long Press Durationlist500 ms
Dimming TypelistStart Stop
Step Valuelist12.5 %
Step Send Intervallist1 s
Move CommandlistToggle
Control TypelistVenetian Blind
Function of LEDlistStatus and Movement Indication
Function of LEDlistOperation Indication
Repeat [Long Press] TelegramunsignedInt 0…10
Value 1listShort Press
Value 2listNone
Value 3listNone
Value 4listNone
Long Press Repeat Intervallist1 s
Multi Press TimeoutunsignedInt 20…20020
Lock Object Transmits StatusunsignedInt 0…10
Dim Direction after Switching OnlistDarker
Double Press TimeoutunsignedInt 20…20020
Step Valuelist1.56 %
Absolute ValueunsignedInt 0…255255
Step DirectionlistIncrease
Double Press ActionlistNone
On Reverse Move Command (if currently moving)listStop Movement
Short Press Action onlistPress
LED Blinking when Status OnunsignedInt 0…10
Color TemperatureunsignedInt 0…655352700
Absolute Value #2unsignedInt 0…2550
Color Temperature #2unsignedInt 0…655356500
BeginunsignedInt 0…2550
EndunsignedInt 0…255255
BeginunsignedInt 0…655352700
EndunsignedInt 0…655356500
StepunsignedInt 0…25526
StepunsignedInt 0…65535380
SequencelistCyclic
Step DirectionlistUp
Show InfounsignedInt 0…10
Data Typelist1-bit toggle
Valuelist0
ValuelistCool
Beginlist1
Counting SequencelistCyclic
StepunsignedInt 0…2551
ValuelistAuto
ValueunsignedInt 0…1000
SceneunsignedInt 1…641
ValuesignedInt -128…1270
ValueunsignedInt 0…2550
Valuefloat -671088…6707600
ValuesignedInt -32768…327670
ValueunsignedInt 0…655350
Valuefloat -1e+38…1e+380
ValuesignedInt -2147483648…21474836470
ValueunsignedInt 0…42949672950
Valuelist00b (No Priority, Off)
ValuelistDecrease, Break
ValuelistUp, Break
Valuecolor#FFFFFF

Version history

ApplicationApp noFingerprintFirst seenSizeFile
SGPxx Switch 3.0 latest$BC2E18C22026-11-25686 KBDownload
SGPxx Switch 2.0$BC2E525A2026-11-25387 KBDownload
SGPxx Switch 1.1$BC2E2F832026-11-25272 KBDownload

About this file

This is the official ETS product database for the EAE SGPxx Mona Switch (48174), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.