| Normal backlight [10..100] | unsignedInt 10…100 | 10 |
| Standby backlight [0..30] | unsignedInt 0…30 | 10 |
| Normal to standby delay time [1..60] | unsignedInt 1…60 | 5 |
| Buzzer volume level [0..5, 0=inactive] | list | 0 |
| Ventilation function | unsignedInt 0…1 | 0 |
| Floor heating function | unsignedInt 0…1 | 0 |
| Room temperature reference from | list | Internal sensor |
| Time period for request external sensor [0...255] | unsignedInt 0…255 | 10 |
| Object type of AC ON/OFF | list | 1Bit |
| Output value for AC ON | unsignedInt 0…255 | 1 |
| Status value for AC ON | unsignedInt 0…255 | 1 |
| Output value for AC OFF | unsignedInt 0…255 | 0 |
| Status value for AC OFF | unsignedInt 0…255 | 0 |
| When voltage recovery, AC status is | list | Last Status |
| ON/OFF status | list | ON |
| Mode | list | Cool |
| Fan speed | list | High |
| Temperature setpoint [16..30] | unsignedInt 16…30 | 26 |
| AC Setting for Preset value='0' | list | OFF |
| AC Setting for Preset value='1' | list | ON |
| Min. setpoint temperature [16..30] | unsignedInt 16…30 | 16 |
| Max. setpoint temperature [16..30] | unsignedInt 16…30 | 30 |
| Scene | unsignedInt 0…1 | 0 |
| Object datatype of 1byte fan speed | list | Percentage (DPT_5.001) |
| Output value for fan speed auto | unsignedInt 0…100 | 0 |
| Output value for fan speed low | unsignedInt 0…100 | 33 |
| Output value for fan speed medium | unsignedInt 0…100 | 67 |
| Output value for fan speed high | unsignedInt 0…100 | 100 |
| Output value for fan speed auto | unsignedInt 0…255 | 0 |
| Output value for fan speed low | unsignedInt 0…255 | 1 |
| Output value for fan speed medium | unsignedInt 0…255 | 2 |
| Output value for fan speed high | unsignedInt 0…255 | 3 |
| Status value for fan speed auto | unsignedInt 0…100 | 0 |
| Status value for fan speed low | unsignedInt 0…100 | 33 |
| Status value for fan speed medium | unsignedInt 0…100 | 67 |
| Status value for fan speed high | unsignedInt 0…100 | 100 |
| Status value for fan speed auto | unsignedInt 0…255 | 0 |
| Status value for fan speed low | unsignedInt 0…255 | 1 |
| Status value for fan speed medium | unsignedInt 0…255 | 2 |
| Status value for fan speed high | unsignedInt 0…255 | 3 |
| Auto mode | unsignedInt 0…1 | 1 |
| Output value for Auto [0..255] | unsignedInt 0…255 | 0 |
| Status value for Auto [0..255] | unsignedInt 0…255 | 0 |
| Heat mode | unsignedInt 0…1 | 1 |
| Output value for Heat [0..255] | unsignedInt 0…255 | 1 |
| Status value for Heat [0..255] | unsignedInt 0…255 | 1 |
| Cool mode | unsignedInt 0…1 | 1 |
| Output value for Cool [0..255] | unsignedInt 0…255 | 3 |
| Status value for Cool [0..255] | unsignedInt 0…255 | 3 |
| Fan mode | unsignedInt 0…1 | 1 |
| Output value for Fan [0..255] | unsignedInt 0…255 | 9 |
| Status value for fan [0..255] | unsignedInt 0…255 | 9 |
| Dehumidification mode | unsignedInt 0…1 | 1 |
| Output value for Dehumidification [0..255] | unsignedInt 0…255 | 14 |
| Status value for Dehumidification [0..255] | unsignedInt 0…255 | 14 |
| 1->Assign scene NO.[1..64,0=inactive] | unsignedInt 0…64 | 0 |
| 2->Assign scene NO.[1..64,0=inactive] | unsignedInt 0…64 | 0 |
| 3->Assign scene NO.[1..64,0=inactive] | unsignedInt 0…64 | 0 |
| 4->Assign scene NO.[1..64,0=inactive] | unsignedInt 0…64 | 0 |
| When voltage recovery, Ventilation status is | list | Last Status |
| 1Bit Preset Speed for value='0' | list | OFF |
| 1Bit Preset Speed for value='1' | list | Medium |
| Object value for fan speed off | list | No.1=0, No.2=0, No.3=0 |
| Object value for fan speed low | list | No.1=1, No.2=0, No.3=0 |
| Object value for fan speed medium | list | No.1=1, No.2=1, No.3=0 |
| Object value for fan speed high | list | No.1=1, No.2=1, No.3=1 |
| Output value for fan speed off | unsignedInt 0…100 | 0 |
| Output value for fan speed off | unsignedInt 0…255 | 0 |
| Status value for fan speed off | unsignedInt 0…100 | 0 |
| Status value for fan speed high | unsignedInt 0…100 | 100 |
| Status value for fan speed off | unsignedInt 0…255 | 0 |
| Fan Status | list | OFF |
| Fan Status | list | Low |
| Fan Status | list | Medium |
| Fan Status | list | High |
| When voltage recovery, Floor heating status is | list | Last status |
| Temperature setpoint [10..30] | unsignedInt 10…30 | 26 |
| 1Bit Preset Speed for value='0' | list | ON |
| 1Bit Preset Speed for value='1' | list | ON |
| Temperature setpoint after download | unsignedInt 10…30 | 26 |
| Output value for Floor heating ON | unsignedInt 0…255 | 1 |
| Status value for Floor heating ON | unsignedInt 0…255 | 1 |
| Output value for Floor heating OFF | unsignedInt 0…255 | 0 |
| Status value for Floor heating OFF | unsignedInt 0…255 | 0 |
| Min. setpoint temperature [10..30] | unsignedInt 10…30 | 10 |
| Max. setpoint temperature [10..30] | unsignedInt 10…30 | 30 |
| Temperature calibration | list | 0.0 |
| Send temperature when the result change by [0..10] | list | 1.0 |
| Cyclically send temperature [0..255,0=inactive] | unsignedInt 0…255 | 10 |
| Object type of Floor heating ON/OFF | list | 1Bit |
| Temperature control method | list | 2 point control |
| Lower Hysteresis[0...200] | unsignedInt 0…200 | 10 |
| Upper Hysteresis[0...200] | unsignedInt 0…200 | 10 |
| Room temperature control function as | list | Disable |
| Setpoint Temperature error | unsignedInt 0…1 | 0 |
| Work mode | list | Master |
| Period for request external sensor [0..255] | unsignedInt 0…255 | 5 |
| Interface display temperature | list | Actual temperature |
| Setpoint temperature adjustment step | list | 0.5K |
| Min. setpoint temperature [5..37] | list | 5 |
| Max. setpoint temperature [5..37] | list | 37 |
| Power on/off status after download | list | ON |
| Power on/off status after voltage recovery | list | As before voltage failure |
| Temperature | list | 10 |
| Room temperature control mode | list | Cooling |
| Room temperature operation mode | unsignedInt 0…1 | 1 |
| Initial setpoint temperature | list | 20.0 |
| Controller status after download | list | Standby mode |
| Controller status after voltage recovery | list | As before voltage failure |
| Extended comfort mode [0..255,0=inactive] | unsignedInt 0…255 | 0 |
| Setpoint method for operating mode | list | Absolute |
| Base setpoint temperature | list | 20.0 |
| Reduced heating in standby mode [0..10] | list | 2 |
| Reduced heating in economy mode [0..10] | list | 4 |
| Setpoint temperature in frost protection [5..10] | list | 7 |
| Setpoint temperature in comfort mode [5..37] | list | 21 |
| Setpoint temperature in standby mode [5..37] | list | 19 |
| Setpoint temperature in economy mode [5..37] | list | 17 |
| Type of heating control | list | Switching on/off(use 2-point control) |
| Invert control value | unsignedInt 0…1 | 0 |
| Lower Hysteresis [0..200] | unsignedInt 0…200 | 10 |
| Upper Hysteresis [0..200] | unsignedInt 0…200 | 10 |
| PWM cycle time [1..255] | unsignedInt 1…255 | 15 |
| Heating speed | list | Hot water heating(5K/150min) |
| Proportional range [10..100] | unsignedInt 10…100 | 40 |
| Reset time [0..255] | unsignedInt 0…255 | 150 |
| Send control value on change by [0..100,0=inactive] | unsignedInt 0…100 | 4 |
| Cyclically send control value[0..255] | unsignedInt 0…255 | 0 |
| Increased cooling in standby mode [0..10] | list | 2 |
| Increased cooling in economy mode[0..10] | list | 4 |
| Setpoint temperature in heat protection[30..37] | list | 35 |
| Setpoint temperature in comfort mode [5..37] | list | 23 |
| Setpoint temperature in standby mode [5..37] | list | 25 |
| Setpoint temperature in economy mode[5..37] | list | 27 |
| Setpoint temperature in heat protection [30..37] | list | 35 |
| Type of cooling control | list | Switching on/off(use 2-point control) |
| Cooling speed | list | Cooling ceiling(5K/240min) |
| Heating/Cooling switchover | list | Via both button and object |
| Heating/Cooling switchover | list | Automatic changeover |
| Heating/Cooling status after download | list | Cooling |
| Heating/Cooling status after voltage recovery | list | As before voltage failure |
| Room temperature control system | list | 4 pipes system |
| Upper dead zone | list | 2.0 |
| Lower dead zone | list | 2.0 |
| Minimum zone between heating and cooling setpoint | list | 2.0 |
| Type of heating/cooling control | list | Switching on/off(use 2-point control) |
| Window contact input function | unsignedInt 0…1 | 0 |
| Delay for window contact [0..65535] | unsignedInt 0…65535 | 15 |
| Operation mode for open window | list | Frost/heat protection |
| Bus presence detector function | unsignedInt 0…1 | 0 |
| Fan | unsignedInt 0…1 | 0 |
| Output value for Fan speed low | unsignedInt 1…100 | 33 |
| Output value for Fan speed medium | unsignedInt 1…100 | 67 |
| Output value for Fan speed high | unsignedInt 1…100 | 100 |
| Status value for Fan speed low | unsignedInt 1…100 | 33 |
| Status value for Fan speed medium | unsignedInt 1…100 | 67 |
| Status value for Fan speed high | unsignedInt 1…100 | 100 |
| Output value for Fan speed low | unsignedInt 1…255 | 1 |
| Output value for Fan speed medium | unsignedInt 1…255 | 2 |
| Output value for Fan speed high | unsignedInt 1…255 | 3 |
| Status value for Fan speed low | unsignedInt 1…255 | 1 |
| Status value for Fan speed medium | unsignedInt 1…255 | 2 |
| Status value for Fan speed high | unsignedInt 1…255 | 3 |
| Automatic operation function | list | Disable |
| Threshold value speed OFF<->low [1..255] | unsignedInt 1…255 | 80 |
| Threshold value speed low<->medium [1..255] | unsignedInt 1…255 | 150 |
| Threshold value speed medium<->high [1..255] | unsignedInt 1…255 | 200 |
| Hysteresis threshold value in +/-[0..50] | unsignedInt 0…50 | 10 |
| Temperature difference speed OFF<->low [1..200] | unsignedInt 1…200 | 20 |
| Temperature difference speed low<->medium [1..200] | unsignedInt 1…200 | 30 |
| Temperature difference speed medium<->high [1..200] | unsignedInt 1…200 | 40 |
| Hysteresis temperature difference in [0..50] | unsignedInt 0…50 | 10 |
| Minimum time in fan speed [0..65535] | unsignedInt 0…65535 | 60 |
| ON/OFF status | list | Unchange |
| Temperature | list | Unchange |
| Operation mode | list | Unchange |
| 5->Assign scene NO.[1..64,0=inactive] | unsignedInt 0…64 | 0 |
| Control value after temp. error [0..100]
(if 2-point control, set value '0'=0, set value '>0'=1) | unsignedInt 0…100 | 0 |
| Low temperature protection when power off | unsignedInt 0…1 | 1 |
| Fan speed auto function | unsignedInt 0…1 | 0 |
| Object type of mode | list | 1Byte |
| Output/Status value for Auto | list | 1 |
| Output/Status value for Cool | list | 0 |
| Output/Status value for Heat | list | 1 |
| Output/Status value for
Dehumidification | list | 1 |
| Output/Status value for Fan | list | 1 |