KNX Database

BX-MFB04

Blumotix · Order number BX-MFB04 · BX-MFB04

BX-MFB04 - 4 channels multifunction actuator

Download .knxprod BX-MFB04 - 4 channels multifunction actuator 0.1 · 145 KB

Product

ManufacturerBlumotix
Product nameBX-MFB04
Order numberBX-MFB04
HardwareBX-MFB04
MediumTwisted Pair
Rail mountedYes
Width (mm)72
RegistrationCertified · 2015-05-27
Languagesen-US, it-IT
Catalog entryM-00A0_H-BX.2DMFB04-0_HP-B023-01-C206_CI-BX.2DMFB04-1
FingerprintC206
SHA-2568201ccc5628cb121de96655db7023aef2d0a6269d0128122766f8ba6c6e0cfc4
First seen2026-11-25
Markets69 markets

Application program: BX-MFB04 - 4 channels multifunction actuator 0.1

Application number$B023
Version0.1
Mask versionMV-0705 (7.5)
KNX Data SecureNo
Minimum ETS version3.0f
Parameters465
Group objects90
Group objects (90)
NoNameFunctionSizeDPTFlags
0Out ASet on-off1 Bit1.1 switchCRW
0Valve AActivation1 Bit1.1 switchCRW
0FancoilSet speed V11 Bit1.1 switchCRW
1Out BSet on-off1 Bit1.1 switchCRW
1Valve BActivation1 Bit1.1 switchCRW
1FancoilSet speed V21 Bit1.1 switchCRW
2Out CSet on-off1 Bit1.1 switchCRW
2Valve CActivation1 Bit1.1 switchCRW
2FancoilSet speed V31 Bit1.1 switchCRW
3Out DSet on-off1 Bit1.1 switchCRW
3Valve DActivation1 Bit1.1 switchCRW
3FancoilSet valve1 Bit1.1 switchCRW
4Out AOn-off status1 Bit1.1 switchCRT
4Valve AActivation status1 Bit1.1 switchCRT
4FancoilStatus speed V11 Bit1.1 switchCRT
5Out BOn-off status1 Bit1.1 switchCRT
5Valve BActivation status1 Bit1.1 switchCRT
5FancoilStatus speed V21 Bit1.1 switchCRT
6Out COn-off status1 Bit1.1 switchCRT
6Valve CActivation status1 Bit1.1 switchCRT
6FancoilStatus speed V31 Bit1.1 switchCRT
7Out DOn-off status1 Bit1.1 switchCRT
7Valve DActivation status1 Bit1.1 switchCRT
7FancoilStatus valve1 Bit1.1 switchCRT
8Out ASet scene1 ByteDPT.5CRWT
9Out BSet scene1 ByteDPT.5CRWT
10Out CSet scene1 ByteDPT.5CRWT
11Out DSet scene1 ByteDPT.5CRWT
12Shutter 1 (A-B)Set up/down1 Bit1.8 up/downCRW
13Shutter 2 (C-D)Set up/down1 Bit1.8 up/downCRW
14Shutter 1 (A-B)Up/down status1 Bit1.8 up/downCRT
15Shutter 2 (C-D)Up/down status1 Bit1.8 up/downCRT
16Shutter 1 (A-B)Set % position1 Byte5.1 percentage (0..100%)CRW
17Shutter 2 (C-D)Set % position1 Byte5.1 percentage (0..100%)CRW
18Shutter 1 (A-B)Position % status1 Byte5.1 percentage (0..100%)CRT
19Shutter 2 (C-D)Position % status1 Byte5.1 percentage (0..100%)CRT
20Shutter 1 (A-B)Set stop1 BitDPT.1CRW
20Shutter 1 (A-B)Stop/slats step1 BitDPT.1CRW
21Shutter 2 (C-D)Set stop1 BitDPT.1CRW
21Shutter 2 (C-D)Stop/slats step1 BitDPT.1CRW
22Shutter 1 (A-B)Set scene1 ByteDPT.5CRWT
23Shutter 2 (C-D)Set scene1 ByteDPT.5CRWT
24Logic function 1Variable1 Bit1.2 booleanCRWT
25Logic function 2Variable1 Bit1.2 booleanCRWT
26Logic function 3Variable1 Bit1.2 booleanCRWT
27Logic function 4Variable1 Bit1.2 booleanCRWT
28Logic function 5Variable1 Bit1.2 booleanCRWT
29Logic function 6Variable1 Bit1.2 booleanCRWT
30Logic function 7Variable1 Bit1.2 booleanCRWT
31Logic function 8Variable1 Bit1.2 booleanCRWT
32Logic function 9Variable1 Bit1.2 booleanCRWT
33Logic function 10Variable1 Bit1.2 booleanCRWT
34Logic function 11Variable1 Bit1.2 booleanCRWT
35Logic function 12Variable1 Bit1.2 booleanCRWT
36Logic function 13Variable1 Bit1.2 booleanCRWT
37Logic function 14Variable1 Bit1.2 booleanCRWT
38Logic function 15Variable1 Bit1.2 booleanCRWT
39Logic function 16Variable1 Bit1.2 booleanCRWT
40Out valve ASet duty cycle %1 Byte5.1 percentage (0..100%)CRW
41Out valve BSet duty cycle %1 Byte5.1 percentage (0..100%)CRW
42Out valve CSet duty cycle %1 Byte5.1 percentage (0..100%)CRW
43Out valve DSet duty cycle %1 Byte5.1 percentage (0..100%)CRW
44Out valve ADuty cycle % status1 Byte5.1 percentage (0..100%)CRT
45Out valve BDuty cycle % status1 Byte5.1 percentage (0..100%)CRT
46Out valve CDuty cycle % status1 Byte5.1 percentage (0..100%)CRT
47Out valve DDuty cycle % status1 Byte5.1 percentage (0..100%)CRT
112Shutter 1 (A-B)Moving up1 Bit1.2 booleanCRT
113Shutter 1 (A-B)Moving down1 Bit1.2 booleanCRT
114Shutter 2 (C-D)Moving up1 Bit1.2 booleanCRT
115Shutter 2 (C-D)Moving down1 Bit1.2 booleanCRT
124Shutter 1 (A-B)Up limit1 Bit1.2 booleanCRT
125Shutter 1 (A-B)Down limit1 Bit1.2 booleanCRT
126Shutter 2 (C-D)Up limit1 Bit1.2 booleanCRT
127Shutter 2 (C-D)Down limit1 Bit1.2 booleanCRT
136Out ASet stairs light1 Bit1.1 switchCRW
137Out BSet stairs light1 Bit1.1 switchCRW
138Out CSet stairs light1 Bit1.1 switchCRW
139Out DSet stairs light1 Bit1.1 switchCRW
148FancoilSet speed %1 Byte5.1 percentage (0..100%)CRW
149FancoilStatus speed %1 Byte5.1 percentage (0..100%)CRT
150Slats 1 (A-B)Set % position1 Byte5.1 percentage (0..100%)CRW
151Slats 2 (C-D)Set % position1 Byte5.1 percentage (0..100%)CRW
156Slats 1 (A-B)Position % status1 Byte5.1 percentage (0..100%)CRT
157Slats 2 (C-D)Position % status1 Byte5.1 percentage (0..100%)CRT
162All single outsSet on-off1 Bit1.1 switchCRW
163All single stairs lightsSet on-off1 Bit1.1 switchCRW
164All shuttersSet up/down1 Bit1.8 up/downCRW
165All shuttersSet % position1 Byte5.1 percentage (0..100%)CRW
166All shutters/all slatsSet stop/step position1 BitDPT.1CRW
167All slatsSet % position1 Byte5.1 percentage (0..100%)CRW
Parameters (90)
ParameterTypeDefault
Module configurationlistBX-MFB04
Logic functions on single outputslistNo
EtsDownloadDetectlistDetectEtsDownload
Enable FancoillistNo
A-B ConfigurationlistSingle outputs
Output A typelistGeneric output
Output B typelistGeneric output
C-D ConfigurationlistSingle outputs
Output D typelistGeneric output
Contact typelistNormally open
Output condition at startuplistAlways off
Stairs light functionlistNo
Time base for stairs lightlist1 Second
Time factor for stairs lightunsignedInt 1…25530
RetriggerablelistNo
Stairs light activation messagelistActive with message 1
Enable sceneslistNo
Enable general commandslistNo
All turn off before new scenelistNo
Scene 1 numberlist1
Scene 1 valuelistOff
Enable scene 1 storagelistNo
Scene 2 numberlist2
Scene 2 numberlistOff
Enable scene 2 storagelistNo
Scene 3 numberlist3
Scene 3 valuelistOff
Enable scene 3 storagelistNo
Scene 4 numberlist4
Scene 4 valuelistOff
Enable scene 4 storagelistNo
Scene 5 numberlist5
Scene 5 valuelistOff
Enable scene 5 storagelistNo
Scene 6 numberlist6
Scene 6 valuelistOff
Enable scene 6 storagelistNo
Scene 7 numberlist7
Scene 7 valuelistOff
Enable scene 7 storagelistNo
Scene 8 numberlist8
Scene 8 valuelistOff
Enable scene 8 storagelistNo
Cycle timelist20 min
Valve anti-lock functionlistNo
Valve anti-lock intervallist3 days
Scene 2 valuelistOff
Travel time (sec)unsignedInt 1…200030
Travel extra time (sec)unsignedInt 0…2553
Stop time between 2 movementslist500 ms
Startup positionlistPrevious position
Movement messagelistNo
Movement message typelistMessage 1 during movement
Limit messagelistNo
Limit message typelistMessage 1 on limit
BlindslistNo
Slats run time (* 100 msec)unsignedInt 1…25550
Slats time when shutter down (*100 msec)unsignedInt 5…25550
Slats unlock time (*100 msec)unsignedInt 0…2550
Slats step timelist300 msec
Slat pos. % at end of drivinglist50 %
Scene 1 valuelist10 %
Scene 2 valuelist20 %
Scene 3 valuelist30 %
Scene 4 valuelist40 %
Scene 5 valuelist50 %
Scene 6 valuelist60 %
Scene 7 valuelist70 %
Scene 8 valuelist80 %
Slats scene 1 valuelist10 %
Slats scene 2 valuelist20 %
Slats scene 3 valuelist30 %
Slats scene 4 valuelist40 %
Slats scene 5 valuelist50 %
Slats scene 6 valuelist60 %
Slats scene 7 valuelist70 %
Slats scene 8 valuelist80 %
Valve relay contact typelistNormally open
Wait for speed change (sec)unsignedInt 0…2552
Heating conditioning delay (min)unsignedInt 0…2550
Set speed message typelist3 messages (1 bit)
Minimum speed thresholdlist0 %
V1-V2 speed thresholdlist40 %
V2-V3 speed thresholdlist70 %
Outputs behavior at startuplistOff
Outputs behavior at shutdownlistUntouched
Logic function enablelistNo
Channel matchedlistA
Logic operatorlistAND
Variable valuelistStraight value

Version history

ApplicationApp noFingerprintFirst seenSizeFile
BX-MFB04 - 4 channels multifunction actuator 0.1 latest$B023C2062026-11-25145 KBDownload

About this file

This is the official ETS product database for the Blumotix BX-MFB04 (BX-MFB04), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.

More from Blumotix

All Blumotix products