KNX Database

Heating actuator 6 channels KNX, with regulation, 24/230V 75316403

Berker · Order number 75316403 · heating, air conditioning, ventilation › regulator

Download .knxprod S75316403 1.1 · 1.2 MB

Product

ManufacturerBerker
Product nameHeating actuator 6 channels KNX, with regulation, 24/230V
Order number75316403
Hardware75316403
MediumTwisted Pair
Bus current (mA)19
Rail mountedYes
RegistrationRegistered · 2019-10-06
Languagesfr-FR, de-DE, it-IT, nl-NL, pt-PT, es-ES, nb-NO, sv-SE
Catalog entryM-0006_H-6.20.2F.2F.2075316403-17_HP-E0D1-11-CFE1_CI-75316403-1
FingerprintCFE1
SHA-256822c9299e50a1d1e0b6afbc96d3ebfd5e343debb1a61927edd142f80d435ae40
First seen2026-11-25
Markets69 markets

Application program: S75316403 1.1

Application number$E0D1
Version1.1
Mask versionMV-07B0 (System B)
KNX Data SecureNo
Minimum ETS version5.0
Parameters6264
Group objects1461
Group objects (1461)
NoNameFunctionSizeDPTFlags
1{{0}}ON/OFF1 Bit1.1 switchCWTU
2{{0}}Valve position in %1 Byte5.1 percentage (0..100%)CWTU
3{{0}}Status indication ON/OFF1 Bit1.1 switchCRT
4{{0}}Status valve position in %1 Byte5.1 percentage (0..100%)CRT
5{{0}}Command value monitoring failure1 Bit1.5 alarmCRT
6{{0}}Short circuit/Overload status indication1 Bit1.5 alarmCRT
7{{0}}Priority2 Bit2.2 boolean controlCWTU
8{{0}}Priority (1 bit)1 Bit1.3 enableCWTU
9{{0}}Status indication priority1 Bit1.3 enableCRT
10{{0}}Heating/Cooling - changeover1 Bit1.100 cooling/heatingCWTU
11{{0}}Command value limitation activation1 Bit1.3 enableCWTU
12{{0}}Hours counter value (h)2 Bytes7.7 time (h)CRT
13{{0}}Hours counter value (s)4 Bytes13.100 time lag (s)CRT
14{{0}}Reset hours counter value1 Bit1.15 resetCWTU
15{{0}}Hours counter setpoint reached1 Bit1.11 stateCRT
16{{0}}Hours counter setpoint (h)2 Bytes7.7 time (h)CWTU
17{{0}}Hours counter setpoint (s)4 Bytes13.100 time lag (s)CWTU
18{{0}}Valve protection date3 Bytes11.1 dateCWTU
19{{0}}Valve protection time3 Bytes10.1 time of dayCWTU
20{{0}}Valve protection date and time8 Bytes19.1 date timeCWTU
21{{0}}Valve protection duration2 Bytes7.6 time (min)CWTU
22{{0}}Valve protection periodicity2 Bytes7.7 time (h)CWTU
23{{0}}Valve protection start/stop1 Bit1.10 start/stopCWTU
24{{0}}Lock-up 11 Bit1.3 enableCWTU
25{{0}}Lock-up 21 Bit1.3 enableCWTU
26{{0}}Status indication lock-up1 Bit1.3 enableCRT
27{{0}}Room temperature failure1 Bit1.5 alarmCWTU
28{{0}}ON/OFF1 Bit1.1 switchCWTU
29{{0}}Valve position in %1 Byte5.1 percentage (0..100%)CWTU
30{{0}}Status indication ON/OFF1 Bit1.1 switchCRT
31{{0}}Status valve position in %1 Byte5.1 percentage (0..100%)CRT
32{{0}}Command value monitoring failure1 Bit1.5 alarmCRT
33{{0}}Short circuit/Overload status indication1 Bit1.5 alarmCRT
34{{0}}Priority2 Bit2.2 boolean controlCWTU
35{{0}}Priority (1 bit)1 Bit1.3 enableCWTU
36{{0}}Status indication priority1 Bit1.3 enableCRT
37{{0}}Heating/Cooling - changeover1 Bit1.100 cooling/heatingCWTU
38{{0}}Command value limitation activation1 Bit1.3 enableCWTU
39{{0}}Hours counter value (h)2 Bytes7.7 time (h)CRT
40{{0}}Hours counter value (s)4 Bytes13.100 time lag (s)CRT
41{{0}}Reset hours counter value1 Bit1.15 resetCWTU
42{{0}}Hours counter setpoint reached1 Bit1.11 stateCRT
43{{0}}Hours counter setpoint (h)2 Bytes7.7 time (h)CWTU
44{{0}}Hours counter setpoint (s)4 Bytes13.100 time lag (s)CWTU
45{{0}}Valve protection date3 Bytes11.1 dateCWTU
46{{0}}Valve protection time3 Bytes10.1 time of dayCWTU
47{{0}}Valve protection date and time8 Bytes19.1 date timeCWTU
48{{0}}Valve protection duration2 Bytes7.6 time (min)CWTU
49{{0}}Valve protection periodicity2 Bytes7.7 time (h)CWTU
50{{0}}Valve protection start/stop1 Bit1.10 start/stopCWTU
51{{0}}Lock-up 11 Bit1.3 enableCWTU
52{{0}}Lock-up 21 Bit1.3 enableCWTU
53{{0}}Status indication lock-up1 Bit1.3 enableCRT
54{{0}}Room temperature failure1 Bit1.5 alarmCWTU
55{{0}}ON/OFF1 Bit1.1 switchCWTU
56{{0}}Valve position in %1 Byte5.1 percentage (0..100%)CWTU
57{{0}}Status indication ON/OFF1 Bit1.1 switchCRT
58{{0}}Status valve position in %1 Byte5.1 percentage (0..100%)CRT
59{{0}}Command value monitoring failure1 Bit1.5 alarmCRT
60{{0}}Short circuit/Overload status indication1 Bit1.5 alarmCRT
61{{0}}Priority2 Bit2.2 boolean controlCWTU
62{{0}}Priority (1 bit)1 Bit1.3 enableCWTU
63{{0}}Status indication priority1 Bit1.3 enableCRT
64{{0}}Heating/Cooling - changeover1 Bit1.100 cooling/heatingCWTU
65{{0}}Command value limitation activation1 Bit1.3 enableCWTU
66{{0}}Hours counter value (h)2 Bytes7.7 time (h)CRT
67{{0}}Hours counter value (s)4 Bytes13.100 time lag (s)CRT
68{{0}}Reset hours counter value1 Bit1.15 resetCWTU
69{{0}}Hours counter setpoint reached1 Bit1.11 stateCRT
70{{0}}Hours counter setpoint (h)2 Bytes7.7 time (h)CWTU
71{{0}}Hours counter setpoint (s)4 Bytes13.100 time lag (s)CWTU
72{{0}}Valve protection date3 Bytes11.1 dateCWTU
73{{0}}Valve protection time3 Bytes10.1 time of dayCWTU
74{{0}}Valve protection date and time8 Bytes19.1 date timeCWTU
75{{0}}Valve protection duration2 Bytes7.6 time (min)CWTU
76{{0}}Valve protection periodicity2 Bytes7.7 time (h)CWTU
77{{0}}Valve protection start/stop1 Bit1.10 start/stopCWTU
78{{0}}Lock-up 11 Bit1.3 enableCWTU
79{{0}}Lock-up 21 Bit1.3 enableCWTU
80{{0}}Status indication lock-up1 Bit1.3 enableCRT
81{{0}}Room temperature failure1 Bit1.5 alarmCWTU
82{{0}}ON/OFF1 Bit1.1 switchCWTU
83{{0}}Valve position in %1 Byte5.1 percentage (0..100%)CWTU
84{{0}}Status indication ON/OFF1 Bit1.1 switchCRT
85{{0}}Status valve position in %1 Byte5.1 percentage (0..100%)CRT
86{{0}}Command value monitoring failure1 Bit1.5 alarmCRT
87{{0}}Short circuit/Overload status indication1 Bit1.5 alarmCRT
88{{0}}Priority2 Bit2.2 boolean controlCWTU
89{{0}}Priority (1 bit)1 Bit1.3 enableCWTU
90{{0}}Status indication priority1 Bit1.3 enableCRT
91{{0}}Heating/Cooling - changeover1 Bit1.100 cooling/heatingCWTU
92{{0}}Command value limitation activation1 Bit1.3 enableCWTU
93{{0}}Hours counter value (h)2 Bytes7.7 time (h)CRT
94{{0}}Hours counter value (s)4 Bytes13.100 time lag (s)CRT
95{{0}}Reset hours counter value1 Bit1.15 resetCWTU
96{{0}}Hours counter setpoint reached1 Bit1.11 stateCRT
97{{0}}Hours counter setpoint (h)2 Bytes7.7 time (h)CWTU
98{{0}}Hours counter setpoint (s)4 Bytes13.100 time lag (s)CWTU
99{{0}}Valve protection date3 Bytes11.1 dateCWTU
100{{0}}Valve protection time3 Bytes10.1 time of dayCWTU
101{{0}}Valve protection date and time8 Bytes19.1 date timeCWTU
102{{0}}Valve protection duration2 Bytes7.6 time (min)CWTU
103{{0}}Valve protection periodicity2 Bytes7.7 time (h)CWTU
104{{0}}Valve protection start/stop1 Bit1.10 start/stopCWTU
105{{0}}Lock-up 11 Bit1.3 enableCWTU
106{{0}}Lock-up 21 Bit1.3 enableCWTU
107{{0}}Status indication lock-up1 Bit1.3 enableCRT
108{{0}}Room temperature failure1 Bit1.5 alarmCWTU
109{{0}}ON/OFF1 Bit1.1 switchCWTU
110{{0}}Valve position in %1 Byte5.1 percentage (0..100%)CWTU
111{{0}}Status indication ON/OFF1 Bit1.1 switchCRT
112{{0}}Status valve position in %1 Byte5.1 percentage (0..100%)CRT
113{{0}}Command value monitoring failure1 Bit1.5 alarmCRT
114{{0}}Short circuit/Overload status indication1 Bit1.5 alarmCRT
115{{0}}Priority2 Bit2.2 boolean controlCWTU
116{{0}}Priority (1 bit)1 Bit1.3 enableCWTU
117{{0}}Status indication priority1 Bit1.3 enableCRT
118{{0}}Heating/Cooling - changeover1 Bit1.100 cooling/heatingCWTU
119{{0}}Command value limitation activation1 Bit1.3 enableCWTU
120{{0}}Hours counter value (h)2 Bytes7.7 time (h)CRT
121{{0}}Hours counter value (s)4 Bytes13.100 time lag (s)CRT
122{{0}}Reset hours counter value1 Bit1.15 resetCWTU
123{{0}}Hours counter setpoint reached1 Bit1.11 stateCRT
124{{0}}Hours counter setpoint (h)2 Bytes7.7 time (h)CWTU
125{{0}}Hours counter setpoint (s)4 Bytes13.100 time lag (s)CWTU
126{{0}}Valve protection date3 Bytes11.1 dateCWTU
127{{0}}Valve protection time3 Bytes10.1 time of dayCWTU
128{{0}}Valve protection date and time8 Bytes19.1 date timeCWTU
129{{0}}Valve protection duration2 Bytes7.6 time (min)CWTU
130{{0}}Valve protection periodicity2 Bytes7.7 time (h)CWTU
131{{0}}Valve protection start/stop1 Bit1.10 start/stopCWTU
132{{0}}Lock-up 11 Bit1.3 enableCWTU
133{{0}}Lock-up 21 Bit1.3 enableCWTU
134{{0}}Status indication lock-up1 Bit1.3 enableCRT
135{{0}}Room temperature failure1 Bit1.5 alarmCWTU
136{{0}}ON/OFF1 Bit1.1 switchCWTU
137{{0}}Valve position in %1 Byte5.1 percentage (0..100%)CWTU
138{{0}}Status indication ON/OFF1 Bit1.1 switchCRT
139{{0}}Status valve position in %1 Byte5.1 percentage (0..100%)CRT
140{{0}}Command value monitoring failure1 Bit1.5 alarmCRT
141{{0}}Short circuit/Overload status indication1 Bit1.5 alarmCRT
142{{0}}Priority2 Bit2.2 boolean controlCWTU
143{{0}}Priority (1 bit)1 Bit1.3 enableCWTU
144{{0}}Status indication priority1 Bit1.3 enableCRT
145{{0}}Heating/Cooling - changeover1 Bit1.100 cooling/heatingCWTU
146{{0}}Command value limitation activation1 Bit1.3 enableCWTU
147{{0}}Hours counter value (h)2 Bytes7.7 time (h)CRT
148{{0}}Hours counter value (s)4 Bytes13.100 time lag (s)CRT
149{{0}}Reset hours counter value1 Bit1.15 resetCWTU
150{{0}}Hours counter setpoint reached1 Bit1.11 stateCRT
151{{0}}Hours counter setpoint (h)2 Bytes7.7 time (h)CWTU
152{{0}}Hours counter setpoint (s)4 Bytes13.100 time lag (s)CWTU
153{{0}}Valve protection date3 Bytes11.1 dateCWTU
154{{0}}Valve protection time3 Bytes10.1 time of dayCWTU
155{{0}}Valve protection date and time8 Bytes19.1 date timeCWTU
156{{0}}Valve protection duration2 Bytes7.6 time (min)CWTU
157{{0}}Valve protection periodicity2 Bytes7.7 time (h)CWTU
158{{0}}Valve protection start/stop1 Bit1.10 start/stopCWTU
159{{0}}Lock-up 11 Bit1.3 enableCWTU
160{{0}}Lock-up 21 Bit1.3 enableCWTU
161{{0}}Status indication lock-up1 Bit1.3 enableCRT
162{{0}}Room temperature failure1 Bit1.5 alarmCWTU
163GeneralSummer/winter mode changeover1 Bit1.1 switchCWTU
164GeneralSummer/winter changeover date3 Bytes11.1 dateCWTU
165GeneralWinter/summer changeover date3 Bytes11.1 dateCWTU
166GeneralValves operating voltage failure1 Bit1.5 alarmCRT
167GeneralReset short circuit/overload1 Bit1.2 booleanCWTU
168GeneralHeat requirement1 Bit1.2 booleanCRT
169GeneralExternal heat requirement1 Bit1.2 booleanCWTU
170GeneralLargest command value1 Byte5.1 percentage (0..100%)CRT
171GeneralExternal largest command value1 Byte5.1 percentage (0..100%)CWTU
172GeneralService mode2 Bit2.1 switch controlCWTU
173GeneralStatus indication service mode1 Bit1.2 booleanCRT
174GeneralPump ON/OFF1 Bit1.1 switchCRT
175GeneralExternal pump control1 Bit1.1 switchCWTU
176GeneralPump protection date3 Bytes11.1 dateCWTU
177GeneralPump protection time3 Bytes10.1 time of dayCWTU
178GeneralPump protection date and time8 Bytes19.1 date timeCWTU
179GeneralPump protection duration2 Bytes7.6 time (min)CWTU
180GeneralPump protection periodicity2 Bytes7.7 time (h)CWTU
181GeneralPump protection start/stop1 Bit1.10 start/stopCWTU
182GeneralHeating activation1 Bit1.1 switchCWTU
183{{0}}Setpoint selection1 Byte20.102 HVAC modeCWTU
184{{0}}Comfort1 Bit1.1 switchCWTU
185{{0}}Standby mode1 Bit1.1 switchCWTU
186{{0}}Night setpoint1 Bit1.1 switchCWTU
187{{0}}Frost/heat protection1 Bit1.1 switchCWTU
188{{0}}Setpoint selection automatic control1 Byte20.102 HVAC modeCWTU
189{{0}}Automatic control deactivation1 Bit1.3 enableCWTU
190{{0}}Heating/Cooling - changeover1 Bit1.100 cooling/heatingCWTU
191{{0}}Priority2 BitCWTU
192{{0}}Priority1 Bit1.11 stateCWTU
193{{0}}Priority1 Byte20.102 HVAC modeCWTU
194{{0}}Windows contact1 Bit1.19 window/doorCWTU
195{{0}}Scene1 Byte18.1 scene controlCWTU
196{{0}}Status indication setpoint selection1 Byte20.102 HVAC modeCRT
197{{0}}Automatic control deactivation status1 Bit1.3 enableCRT
198{{0}}Heating/Cooling - status indication1 Bit1.100 cooling/heatingCRT
199{{0}}Status indication heating active1 Bit1.11 stateCRT
200{{0}}Status indication cooling active1 Bit1.11 stateCRT
201{{0}}Status indication priority1 Bit1.11 stateCRT
202{{0}}ON/OFF - basic heating1 Bit1.1 switchCRT
202{{0}}ON/OFF1 Bit1.1 switchCRT
203{{0}}Valve position in % - basic heating1 Byte5.1 percentage (0..100%)CRT
203{{0}}Valve position in %1 Byte5.1 percentage (0..100%)CRT
204{{0}}ON/OFF - basic cooling1 Bit1.1 switchCRT
205{{0}}Valve position in % - basic cooling1 Byte5.1 percentage (0..100%)CRT
206{{0}}ON/OFF - additional heating1 Bit1.1 switchCRT
206{{0}}ON/OFF - additional1 Bit1.1 switchCRT
207{{0}}Valve position in % - additional heating1 Byte5.1 percentage (0..100%)CRT
207{{0}}Valve position in % - additional1 Byte5.1 percentage (0..100%)CRT
208{{0}}ON/OFF - additional cooling1 Bit1.1 switchCRT
209{{0}}Valve position in % - additional cooling1 Byte5.1 percentage (0..100%)CRT
210{{0}}Room temperature 12 Bytes9.1 temperature (°C)CWTU
211{{0}}Room temperature 22 Bytes9.1 temperature (°C)CWTU
212{{0}}Room temperature 32 Bytes9.1 temperature (°C)CWTU
213{{0}}Floor temperature2 Bytes9.1 temperature (°C)CWTU
214{{0}}Status indication room temperature2 Bytes9.1 temperature (°C)CRT
215{{0}}Room temperature failure1 Bit1.5 alarmCRT
216{{0}}Minimum room temperature1 Bit1.5 alarmCRT
217{{0}}Maximum room temperature1 Bit1.5 alarmCRT
218{{0}}Ventilation automatic/manual mode1 Bit1.1 switchCWTU
219{{0}}Status ventilation step 1-61 Byte5.10 counter pulses (0..255)CWTU
220{{0}}Status ventilation step 11 Bit1.1 switchCWTU
221{{0}}Status ventilation step 21 Bit1.1 switchCWTU
222{{0}}Status ventilation step 31 Bit1.1 switchCWTU
223{{0}}Status ventilation step 41 Bit1.1 switchCWTU
224{{0}}Status ventilation step 51 Bit1.1 switchCWTU
225{{0}}Status ventilation step 61 Bit1.1 switchCWTU
226{{0}}Ventilation step 1-61 Byte5.10 counter pulses (0..255)CRT
227{{0}}Ventilation step 11 Bit1.1 switchCRT
228{{0}}Ventilation step 21 Bit1.1 switchCRT
229{{0}}Ventilation step 31 Bit1.1 switchCRT
230{{0}}Ventilation step 41 Bit1.1 switchCRT
231{{0}}Ventilation step 51 Bit1.1 switchCRT
232{{0}}Ventilation step 61 Bit1.1 switchCRT
233{{0}}Comfort setpoint heating2 Bytes9.1 temperature (°C)CWTU
233{{0}}Reference setpoint2 Bytes9.1 temperature (°C)CWTU
234{{0}}Standby setpoint heating2 Bytes9.1 temperature (°C)CWTU
235{{0}}Night setpoint heating2 Bytes9.1 temperature (°C)CWTU
236{{0}}Frost protection setpoint heating2 Bytes9.1 temperature (°C)CWTU
237{{0}}Setpoints heating8 BytesCWTU
238{{0}}Comfort setpoint cooling2 Bytes9.1 temperature (°C)CWTU
239{{0}}Standby setpoint cooling2 Bytes9.1 temperature (°C)CWTU
240{{0}}Night setpoint cooling2 Bytes9.1 temperature (°C)CWTU
241{{0}}Heat protection setpoint cooling2 Bytes9.1 temperature (°C)CWTU
242{{0}}Setpoints cooling8 BytesCWTU
243{{0}}Setpoint shift2 Bytes9.2 temperature difference (K)CWTU
244{{0}}Current setpoint2 Bytes9.1 temperature (°C)CWTU
245{{0}}Status indication setpoint shift2 Bytes9.2 temperature difference (K)CRT
246{{0}}Status indication reference setpoint2 Bytes9.1 temperature (°C)CRT
247{{0}}Status indication comfort setpoint heating2 Bytes9.1 temperature (°C)CRT
248{{0}}Status indication standby setpoint heating2 Bytes9.1 temperature (°C)CRT
249{{0}}Status indication night setpoint heating2 Bytes9.1 temperature (°C)CRT
250{{0}}Status indication frost protection setpoint heating2 Bytes9.1 temperature (°C)CRT
251{{0}}Status indication setpoints heating8 BytesCRT
252{{0}}Status indication comfort setpoint cooling2 Bytes9.1 temperature (°C)CRT
253{{0}}Status indication standby setpoint cooling2 Bytes9.1 temperature (°C)CRT
254{{0}}Status indication night setpoint cooling2 Bytes9.1 temperature (°C)CRT
255{{0}}Status indication heat protection setpoint cooling2 Bytes9.1 temperature (°C)CRT
256{{0}}Status indication setpoints cooling8 BytesCRT
257{{0}}Status current setpoint2 Bytes9.1 temperature (°C)CRT
258{{0}}Presence1 Bit1.1 switchCWTU
259{{0}}Lock-up additional step1 Bit1.1 switchCWTU
260{{0}}Heating deactivation1 Bit1.3 enableCWTU
261{{0}}Cooling deactivation1 Bit1.3 enableCWTU
262{{0}}Heating deactivation status1 Bit1.3 enableCRT
263{{0}}Cooling deactivation status1 Bit1.3 enableCRT
264{{0}}Thermostat deactivation1 Bit1.3 enableCWTU
265{{0}}Status indication thermostat deactivation1 Bit1.3 enableCRT
266{{0}}Timer1 Bit1.10 start/stopCWTU
267{{0}}Timer duration3 Bytes10.1 time of dayCWTU
268{{0}}Timer setpoint selection1 Byte20.102 HVAC modeCWTU
269{{0}}Preset 11 Bit1.3 enableCWTU
270{{0}}Preset 21 Bit1.3 enableCWTU
271{{0}}Preset 1 authorization1 Bit1.3 enableCWTU
272{{0}}Preset 2 authorization1 Bit1.3 enableCWTU
273{{0}}Lock-up 11 Bit1.3 enableCWTU
274{{0}}Lock-up 21 Bit1.3 enableCWTU
275{{0}}Status indication lock-up1 Bit1.3 enableCRT
276{{0}}Valve protection date3 Bytes11.1 dateCWTU
277{{0}}Valve protection time3 Bytes10.1 time of dayCWTU
278{{0}}Valve protection date and time8 Bytes19.1 date timeCWTU
279{{0}}Valve protection duration2 Bytes7.6 time (min)CWTU
280{{0}}Valve protection periodicity2 Bytes7.7 time (h)CWTU
281{{0}}Valve protection start/stop1 Bit1.10 start/stopCWTU
282{{0}}Setpoint selection1 Byte20.102 HVAC modeCWTU
283{{0}}Comfort1 Bit1.1 switchCWTU
284{{0}}Standby mode1 Bit1.1 switchCWTU
285{{0}}Night setpoint1 Bit1.1 switchCWTU
286{{0}}Frost/heat protection1 Bit1.1 switchCWTU
287{{0}}Setpoint selection automatic control1 Byte20.102 HVAC modeCWTU
288{{0}}Automatic control deactivation1 Bit1.3 enableCWTU
289{{0}}Heating/Cooling - changeover1 Bit1.100 cooling/heatingCWTU
290{{0}}Priority2 Bit2.2 boolean controlCWTU
291{{0}}Priority1 Bit1.11 stateCWTU
292{{0}}Priority1 Byte20.102 HVAC modeCWTU
293{{0}}Windows contact1 Bit1.19 window/doorCWTU
294{{0}}Scene1 Byte18.1 scene controlCWTU
295{{0}}Status indication setpoint selection1 Byte20.102 HVAC modeCRT
296{{0}}Automatic control deactivation status1 Bit1.3 enableCRT
297{{0}}Heating/Cooling - status indication1 Bit1.100 cooling/heatingCRT
298{{0}}Status indication heating active1 Bit1.11 stateCRT
299{{0}}Status indication cooling active1 Bit1.11 stateCRT
300{{0}}Status indication priority1 Bit1.11 stateCRT
301{{0}}ON/OFF - basic heating1 Bit1.1 switchCRT
301{{0}}ON/OFF1 Bit1.1 switchCRT
302{{0}}Valve position in % - basic heating1 Byte5.1 percentage (0..100%)CRT
302{{0}}Valve position in %1 Byte5.1 percentage (0..100%)CRT
303{{0}}ON/OFF - basic cooling1 Bit1.1 switchCRT
304{{0}}Valve position in % - basic cooling1 Byte5.1 percentage (0..100%)CRT
305{{0}}ON/OFF - additional heating1 Bit1.1 switchCRT
305{{0}}ON/OFF - additional1 Bit1.1 switchCRT
306{{0}}Valve position in % - additional heating1 Byte5.1 percentage (0..100%)CRT
306{{0}}Valve position in % - additional1 Byte5.1 percentage (0..100%)CRT
307{{0}}ON/OFF - additional cooling1 Bit1.1 switchCRT
308{{0}}Valve position in % - additional cooling1 Byte5.1 percentage (0..100%)CRT
309{{0}}Room temperature 12 Bytes9.1 temperature (°C)CWTU
310{{0}}Room temperature 22 Bytes9.1 temperature (°C)CWTU
311{{0}}Room temperature 32 Bytes9.1 temperature (°C)CWTU
312{{0}}Floor temperature2 Bytes9.1 temperature (°C)CWTU
313{{0}}Status indication room temperature2 Bytes9.1 temperature (°C)CRT
314{{0}}Room temperature failure1 Bit1.5 alarmCRT
315{{0}}Minimum room temperature1 Bit1.5 alarmCRT
316{{0}}Maximum room temperature1 Bit1.5 alarmCRT
317{{0}}Ventilation automatic/manual mode1 Bit1.1 switchCWTU
318{{0}}Status ventilation step 1-61 Byte5.10 counter pulses (0..255)CWTU
319{{0}}Status ventilation step 11 Bit1.1 switchCWTU
320{{0}}Status ventilation step 21 Bit1.1 switchCWTU
321{{0}}Status ventilation step 31 Bit1.1 switchCWTU
322{{0}}Status ventilation step 41 Bit1.1 switchCWTU
323{{0}}Status ventilation step 51 Bit1.1 switchCWTU
324{{0}}Status ventilation step 61 Bit1.1 switchCWTU
325{{0}}Ventilation step 1-61 Byte5.10 counter pulses (0..255)CRT
326{{0}}Ventilation step 11 Bit1.1 switchCRT
327{{0}}Ventilation step 21 Bit1.1 switchCRT
328{{0}}Ventilation step 31 Bit1.1 switchCRT
329{{0}}Ventilation step 41 Bit1.1 switchCRT
330{{0}}Ventilation step 51 Bit1.1 switchCRT
331{{0}}Ventilation step 61 Bit1.1 switchCRT
332{{0}}Comfort setpoint heating2 Bytes9.1 temperature (°C)CWTU
332{{0}}Reference setpoint2 Bytes9.1 temperature (°C)CWTU
333{{0}}Standby setpoint heating2 Bytes9.1 temperature (°C)CWTU
334{{0}}Night setpoint heating2 Bytes9.1 temperature (°C)CWTU
335{{0}}Frost protection setpoint heating2 Bytes9.1 temperature (°C)CWTU
336{{0}}Setpoints heating8 BytesCWTU
337{{0}}Comfort setpoint cooling2 Bytes9.1 temperature (°C)CWTU
338{{0}}Standby setpoint cooling2 Bytes9.1 temperature (°C)CWTU
339{{0}}Night setpoint cooling2 Bytes9.1 temperature (°C)CWTU
340{{0}}Heat protection setpoint cooling2 Bytes9.1 temperature (°C)CWTU
341{{0}}Setpoints cooling8 BytesCWTU
342{{0}}Setpoint shift2 Bytes9.2 temperature difference (K)CWTU
343{{0}}Current setpoint2 Bytes9.1 temperature (°C)CWTU
344{{0}}Status indication setpoint shift2 Bytes9.2 temperature difference (K)CRT
345{{0}}Status indication reference setpoint2 Bytes9.1 temperature (°C)CRT
346{{0}}Status indication comfort setpoint heating2 Bytes9.1 temperature (°C)CRT
347{{0}}Status indication standby setpoint heating2 Bytes9.1 temperature (°C)CRT
348{{0}}Status indication night setpoint heating2 Bytes9.1 temperature (°C)CRT
349{{0}}Status indication frost protection setpoint heating2 Bytes9.1 temperature (°C)CRT
350{{0}}Status indication setpoints heating8 BytesCRT
351{{0}}Status indication comfort setpoint cooling2 Bytes9.1 temperature (°C)CRT
352{{0}}Status indication standby setpoint cooling2 Bytes9.1 temperature (°C)CRT
353{{0}}Status indication night setpoint cooling2 Bytes9.1 temperature (°C)CRT
354{{0}}Status indication heat protection setpoint cooling2 Bytes9.1 temperature (°C)CRT
355{{0}}Status indication setpoints cooling8 BytesCRT
356{{0}}Status current setpoint2 Bytes9.1 temperature (°C)CRT
357{{0}}Presence1 Bit1.1 switchCWTU
358{{0}}Lock-up additional step1 Bit1.1 switchCWTU
359{{0}}Heating deactivation1 Bit1.3 enableCWTU
360{{0}}Cooling deactivation1 Bit1.3 enableCWTU
361{{0}}Heating deactivation status1 Bit1.3 enableCRT
362{{0}}Cooling deactivation status1 Bit1.3 enableCRT
363{{0}}Thermostat deactivation1 Bit1.3 enableCWTU
364{{0}}Status indication thermostat deactivation1 Bit1.3 enableCRT
365{{0}}Timer1 Bit1.10 start/stopCWTU
366{{0}}Timer duration3 Bytes10.1 time of dayCWTU
367{{0}}Timer setpoint selection1 Byte20.102 HVAC modeCWTU
368{{0}}Preset 11 Bit1.3 enableCWTU
369{{0}}Preset 21 Bit1.3 enableCWTU
370{{0}}Preset 1 authorization1 Bit1.3 enableCWTU
371{{0}}Preset 2 authorization1 Bit1.3 enableCWTU
372{{0}}Lock-up 11 Bit1.3 enableCWTU
373{{0}}Lock-up 21 Bit1.3 enableCWTU
374{{0}}Status indication lock-up1 Bit1.3 enableCRT
375{{0}}Valve protection date3 Bytes11.1 dateCWTU
376{{0}}Valve protection time3 Bytes10.1 time of dayCWTU
377{{0}}Valve protection date and time8 Bytes19.1 date timeCWTU
378{{0}}Valve protection duration2 Bytes7.6 time (min)CWTU
379{{0}}Valve protection periodicity2 Bytes7.7 time (h)CWTU
380{{0}}Valve protection start/stop1 Bit1.10 start/stopCWTU
381{{0}}Setpoint selection1 Byte20.102 HVAC modeCWTU
382{{0}}Comfort1 Bit1.1 switchCWTU
383{{0}}Standby mode1 Bit1.1 switchCWTU
384{{0}}Night setpoint1 Bit1.1 switchCWTU
385{{0}}Frost/heat protection1 Bit1.1 switchCWTU
386{{0}}Setpoint selection automatic control1 Byte20.102 HVAC modeCWTU
387{{0}}Automatic control deactivation1 Bit1.3 enableCWTU
388{{0}}Heating/Cooling - changeover1 Bit1.100 cooling/heatingCWTU
389{{0}}Priority2 Bit2.2 boolean controlCWTU
390{{0}}Priority1 Bit1.11 stateCWTU
391{{0}}Priority1 Byte20.102 HVAC modeCWTU
392{{0}}Windows contact1 Bit1.19 window/doorCWTU
393{{0}}Scene1 Byte18.1 scene controlCWTU
394{{0}}Status indication setpoint selection1 Byte20.102 HVAC modeCRT
395{{0}}Automatic control deactivation status1 Bit1.3 enableCRT
396{{0}}Heating/Cooling - status indication1 Bit1.100 cooling/heatingCRT
397{{0}}Status indication heating active1 Bit1.11 stateCRT
398{{0}}Status indication cooling active1 Bit1.11 stateCRT
399{{0}}Status indication priority1 Bit1.11 stateCRT
400{{0}}ON/OFF - basic heating1 Bit1.1 switchCRT
400{{0}}ON/OFF1 Bit1.1 switchCRT
401{{0}}Valve position in % - basic heating1 Byte5.1 percentage (0..100%)CRT
401{{0}}Valve position in %1 Byte5.1 percentage (0..100%)CRT
402{{0}}ON/OFF - basic cooling1 Bit1.1 switchCRT
403{{0}}Valve position in % - basic cooling1 Byte5.1 percentage (0..100%)CRT
404{{0}}ON/OFF - additional heating1 Bit1.1 switchCRT
404{{0}}ON/OFF - additional1 Bit1.1 switchCRT
405{{0}}Valve position in % - additional heating1 Byte5.1 percentage (0..100%)CRT
405{{0}}Valve position in % - additional1 Byte5.1 percentage (0..100%)CRT
406{{0}}ON/OFF - additional cooling1 Bit1.1 switchCRT
407{{0}}Valve position in % - additional cooling1 Byte5.1 percentage (0..100%)CRT
408{{0}}Room temperature 12 Bytes9.1 temperature (°C)CWTU
409{{0}}Room temperature 22 Bytes9.1 temperature (°C)CWTU
410{{0}}Room temperature 32 Bytes9.1 temperature (°C)CWTU
411{{0}}Floor temperature2 Bytes9.1 temperature (°C)CWTU
412{{0}}Status indication room temperature2 Bytes9.1 temperature (°C)CRT
413{{0}}Room temperature failure1 Bit1.5 alarmCRT
414{{0}}Minimum room temperature1 Bit1.5 alarmCRT
415{{0}}Maximum room temperature1 Bit1.5 alarmCRT
416{{0}}Ventilation automatic/manual mode1 Bit1.1 switchCWTU
417{{0}}Status ventilation step 1-61 Byte5.10 counter pulses (0..255)CWTU
418{{0}}Status ventilation step 11 Bit1.1 switchCWTU
419{{0}}Status ventilation step 21 Bit1.1 switchCWTU
420{{0}}Status ventilation step 31 Bit1.1 switchCWTU
421{{0}}Status ventilation step 41 Bit1.1 switchCWTU
422{{0}}Status ventilation step 51 Bit1.1 switchCWTU
423{{0}}Status ventilation step 61 Bit1.1 switchCWTU
424{{0}}Ventilation step 1-61 Byte5.10 counter pulses (0..255)CRT
425{{0}}Ventilation step 11 Bit1.1 switchCRT
426{{0}}Ventilation step 21 Bit1.1 switchCRT
427{{0}}Ventilation step 31 Bit1.1 switchCRT
428{{0}}Ventilation step 41 Bit1.1 switchCRT
429{{0}}Ventilation step 51 Bit1.1 switchCRT
430{{0}}Ventilation step 61 Bit1.1 switchCRT
431{{0}}Comfort setpoint heating2 Bytes9.1 temperature (°C)CWTU
431{{0}}Comfort setpoint2 Bytes9.1 temperature (°C)CWTU
431{{0}}Reference setpoint2 Bytes9.1 temperature (°C)CWTU
432{{0}}Standby setpoint heating2 Bytes9.1 temperature (°C)CWTU
433{{0}}Night setpoint heating2 Bytes9.1 temperature (°C)CWTU
434{{0}}Frost protection setpoint heating2 Bytes9.1 temperature (°C)CWTU
435{{0}}Setpoints heating8 BytesCWTU
436{{0}}Comfort setpoint cooling2 Bytes9.1 temperature (°C)CWTU
437{{0}}Standby setpoint cooling2 Bytes9.1 temperature (°C)CWTU
438{{0}}Night setpoint cooling2 Bytes9.1 temperature (°C)CWTU
439{{0}}Heat protection setpoint cooling2 Bytes9.1 temperature (°C)CWTU
440{{0}}Setpoints cooling8 BytesCWTU
441{{0}}Setpoint shift2 Bytes9.2 temperature difference (K)CWTU
442{{0}}Current setpoint2 Bytes9.1 temperature (°C)CWTU
443{{0}}Status indication setpoint shift2 Bytes9.2 temperature difference (K)CRT
444{{0}}Status indication reference setpoint2 Bytes9.1 temperature (°C)CRT
445{{0}}Status indication comfort setpoint heating2 Bytes9.1 temperature (°C)CRT
446{{0}}Status indication standby setpoint heating2 Bytes9.1 temperature (°C)CRT
447{{0}}Status indication night setpoint heating2 Bytes9.1 temperature (°C)CRT
448{{0}}Status indication frost protection setpoint heating2 Bytes9.1 temperature (°C)CRT
449{{0}}Status indication setpoints heating8 BytesCRT
450{{0}}Status indication comfort setpoint cooling2 Bytes9.1 temperature (°C)CRT
451{{0}}Status indication standby setpoint cooling2 Bytes9.1 temperature (°C)CRT
452{{0}}Status indication night setpoint cooling2 Bytes9.1 temperature (°C)CRT
453{{0}}Status indication heat protection setpoint cooling2 Bytes9.1 temperature (°C)CRT
454{{0}}Status indication setpoints cooling8 BytesCRT
455{{0}}Status current setpoint2 Bytes9.1 temperature (°C)CRT
456{{0}}Presence1 Bit1.1 switchCWTU
457{{0}}Lock-up additional step1 Bit1.1 switchCWTU
458{{0}}Heating deactivation1 Bit1.3 enableCWTU
459{{0}}Cooling deactivation1 Bit1.3 enableCWTU
460{{0}}Heating deactivation status1 Bit1.3 enableCRT
461{{0}}Cooling deactivation status1 Bit1.3 enableCRT
462{{0}}Thermostat deactivation1 Bit1.3 enableCWTU
463{{0}}Status indication thermostat deactivation1 Bit1.3 enableCRT
464{{0}}Timer1 Bit1.10 start/stopCWTU
465{{0}}Timer duration3 Bytes10.1 time of dayCWTU
466{{0}}Timer setpoint selection1 Byte20.102 HVAC modeCWTU
467{{0}}Preset 11 Bit1.3 enableCWTU
468{{0}}Preset 21 Bit1.3 enableCWTU
469{{0}}Preset 1 authorization1 Bit1.3 enableCWTU
470{{0}}Preset 2 authorization1 Bit1.3 enableCWTU
471{{0}}Lock-up 11 Bit1.3 enableCWTU
472{{0}}Lock-up 21 Bit1.3 enableCWTU
473{{0}}Status indication lock-up1 Bit1.3 enableCRT
474{{0}}Valve protection date3 Bytes11.1 dateCWTU
475{{0}}Valve protection time3 Bytes10.1 time of dayCWTU
476{{0}}Valve protection date and time8 Bytes19.1 date timeCWTU
477{{0}}Valve protection duration2 Bytes7.6 time (min)CWTU
478{{0}}Valve protection periodicity2 Bytes7.7 time (h)CWTU
479{{0}}Valve protection start/stop1 Bit1.10 start/stopCWTU
480{{0}}Setpoint selection1 Byte20.102 HVAC modeCWTU
481{{0}}Comfort1 Bit1.1 switchCWTU
482{{0}}Standby mode1 Bit1.1 switchCWTU
483{{0}}Night setpoint1 Bit1.1 switchCWTU
484{{0}}Frost/heat protection1 Bit1.1 switchCWTU
485{{0}}Setpoint selection automatic control1 Byte20.102 HVAC modeCWTU
486{{0}}Automatic control deactivation1 Bit1.3 enableCWTU
487{{0}}Heating/Cooling - changeover1 Bit1.100 cooling/heatingCWTU
488{{0}}Priority2 Bit2.2 boolean controlCWTU
489{{0}}Priority1 Bit1.11 stateCWTU
490{{0}}Priority1 Byte20.102 HVAC modeCWTU
491{{0}}Windows contact1 Bit1.19 window/doorCWTU
492{{0}}Scene1 Byte18.1 scene controlCWTU
493{{0}}Status indication setpoint selection1 Byte20.102 HVAC modeCRT
494{{0}}Automatic control deactivation status1 Bit1.3 enableCRT
495{{0}}Heating/Cooling - status indication1 Bit1.100 cooling/heatingCRT
496{{0}}Status indication heating active1 Bit1.11 stateCRT
497{{0}}Status indication cooling active1 Bit1.11 stateCRT
498{{0}}Status indication priority1 Bit1.11 stateCRT
499{{0}}ON/OFF - basic heating1 Bit1.1 switchCRT
499{{0}}ON/OFF1 Bit1.1 switchCRT
500{{0}}Valve position in % - basic heating1 Byte5.1 percentage (0..100%)CRT
500{{0}}Valve position in %1 Byte5.1 percentage (0..100%)CRT
501{{0}}ON/OFF - basic cooling1 Bit1.1 switchCRT
502{{0}}Valve position in % - basic cooling1 Byte5.1 percentage (0..100%)CRT
503{{0}}ON/OFF - additional heating1 Bit1.1 switchCRT
503{{0}}ON/OFF - additional1 Bit1.1 switchCRT
504{{0}}Valve position in % - additional heating1 Byte5.1 percentage (0..100%)CRT
504{{0}}Valve position in % - additional1 Byte5.1 percentage (0..100%)CRT
505{{0}}ON/OFF - additional cooling1 Bit1.1 switchCRT
506{{0}}Valve position in % - additional cooling1 Byte5.1 percentage (0..100%)CRT
507{{0}}Room temperature 12 Bytes9.1 temperature (°C)CWTU
508{{0}}Room temperature 22 Bytes9.1 temperature (°C)CWTU
509{{0}}Room temperature 32 Bytes9.1 temperature (°C)CWTU
510{{0}}Floor temperature2 Bytes9.1 temperature (°C)CWTU
511{{0}}Status indication room temperature2 Bytes9.1 temperature (°C)CRT
512{{0}}Room temperature failure1 Bit1.5 alarmCRT
513{{0}}Minimum room temperature1 Bit1.5 alarmCRT
514{{0}}Maximum room temperature1 Bit1.5 alarmCRT
515{{0}}Ventilation automatic/manual mode1 Bit1.1 switchCWTU
516{{0}}Status ventilation step 1-61 Byte5.10 counter pulses (0..255)CWTU
517{{0}}Status ventilation step 11 Bit1.1 switchCWTU
518{{0}}Status ventilation step 21 Bit1.1 switchCWTU
519{{0}}Status ventilation step 31 Bit1.1 switchCWTU
520{{0}}Status ventilation step 41 Bit1.1 switchCWTU
521{{0}}Status ventilation step 51 Bit1.1 switchCWTU
522{{0}}Status ventilation step 61 Bit1.1 switchCWTU
523{{0}}Ventilation step 1-61 Byte5.10 counter pulses (0..255)CRT
524{{0}}Ventilation step 11 Bit1.1 switchCRT
525{{0}}Ventilation step 21 Bit1.1 switchCRT
526{{0}}Ventilation step 31 Bit1.1 switchCRT
527{{0}}Ventilation step 41 Bit1.1 switchCRT
528{{0}}Ventilation step 51 Bit1.1 switchCRT
529{{0}}Ventilation step 61 Bit1.1 switchCRT
530{{0}}Comfort setpoint heating2 Bytes9.1 temperature (°C)CWTU
530{{0}}Comfort setpoint2 Bytes9.1 temperature (°C)CWTU
530{{0}}Reference setpoint2 Bytes9.1 temperature (°C)CWTU
531{{0}}Standby setpoint heating2 Bytes9.1 temperature (°C)CWTU
532{{0}}Night setpoint heating2 Bytes9.1 temperature (°C)CWTU
533{{0}}Frost protection setpoint heating2 Bytes9.1 temperature (°C)CWTU
534{{0}}Setpoints heating8 BytesCWTU
535{{0}}Comfort setpoint cooling2 Bytes9.1 temperature (°C)CWTU
536{{0}}Standby setpoint cooling2 Bytes9.1 temperature (°C)CWTU
537{{0}}Night setpoint cooling2 Bytes9.1 temperature (°C)CWTU
538{{0}}Heat protection setpoint cooling2 Bytes9.1 temperature (°C)CWTU
539{{0}}Setpoints cooling8 BytesCWTU
540{{0}}Setpoint shift2 Bytes9.2 temperature difference (K)CWTU
541{{0}}Current setpoint2 Bytes9.1 temperature (°C)CWTU
542{{0}}Status indication setpoint shift2 Bytes9.2 temperature difference (K)CRT
543{{0}}Status indication reference setpoint2 Bytes9.1 temperature (°C)CRT
544{{0}}Status indication comfort setpoint heating2 Bytes9.1 temperature (°C)CRT
545{{0}}Status indication standby setpoint heating2 Bytes9.1 temperature (°C)CRT
546{{0}}Status indication night setpoint heating2 Bytes9.1 temperature (°C)CRT
547{{0}}Status indication frost protection setpoint heating2 Bytes9.1 temperature (°C)CRT
548{{0}}Status indication setpoints heating8 BytesCRT
549{{0}}Status indication comfort setpoint cooling2 Bytes9.1 temperature (°C)CRT
550{{0}}Status indication standby setpoint cooling2 Bytes9.1 temperature (°C)CRT
551{{0}}Status indication night setpoint cooling2 Bytes9.1 temperature (°C)CRT
552{{0}}Status indication heat protection setpoint cooling2 Bytes9.1 temperature (°C)CRT
553{{0}}Status indication setpoints cooling8 BytesCRT
554{{0}}Status current setpoint2 Bytes9.1 temperature (°C)CRT
555{{0}}Presence1 Bit1.1 switchCWTU
556{{0}}Lock-up additional step1 Bit1.1 switchCWTU
557{{0}}Heating deactivation1 Bit1.3 enableCWTU
558{{0}}Cooling deactivation1 Bit1.3 enableCWTU
559{{0}}Heating deactivation status1 Bit1.3 enableCRT
560{{0}}Cooling deactivation status1 Bit1.3 enableCRT
561{{0}}Thermostat deactivation1 Bit1.3 enableCWTU
562{{0}}Status indication thermostat deactivation1 Bit1.3 enableCRT
563{{0}}Timer1 Bit1.10 start/stopCWTU
564{{0}}Timer duration3 Bytes10.1 time of dayCWTU
565{{0}}Timer setpoint selection1 Byte20.102 HVAC modeCWTU
566{{0}}Preset 11 Bit1.3 enableCWTU
567{{0}}Preset 21 Bit1.3 enableCWTU
568{{0}}Preset 1 authorization1 Bit1.3 enableCWTU
569{{0}}Preset 2 authorization1 Bit1.3 enableCWTU
570{{0}}Lock-up 11 Bit1.3 enableCWTU
571{{0}}Lock-up 21 Bit1.3 enableCWTU
572{{0}}Status indication lock-up1 Bit1.3 enableCRT
573{{0}}Valve protection date3 Bytes11.1 dateCWTU
574{{0}}Valve protection time3 Bytes10.1 time of dayCWTU
575{{0}}Valve protection date and time8 Bytes19.1 date timeCWTU
576{{0}}Valve protection duration2 Bytes7.6 time (min)CWTU
577{{0}}Valve protection periodicity2 Bytes7.7 time (h)CWTU
578{{0}}Valve protection start/stop1 Bit1.10 start/stopCWTU
579{{0}}Setpoint selection1 Byte20.102 HVAC modeCWTU
580{{0}}Comfort1 Bit1.1 switchCWTU
581{{0}}Standby mode1 Bit1.1 switchCWTU
582{{0}}Night setpoint1 Bit1.1 switchCWTU
583{{0}}Frost/heat protection1 Bit1.1 switchCWTU
584{{0}}Setpoint selection automatic control1 Byte20.102 HVAC modeCWTU
585{{0}}Automatic control deactivation1 Bit1.3 enableCWTU
586{{0}}Heating/Cooling - changeover1 Bit1.100 cooling/heatingCWTU
587{{0}}Priority2 Bit2.2 boolean controlCWTU
588{{0}}Priority1 Bit1.11 stateCWTU
589{{0}}Priority1 Byte20.102 HVAC modeCWTU
590{{0}}Windows contact1 Bit1.19 window/doorCWTU
591{{0}}Scene1 Byte18.1 scene controlCWTU
592{{0}}Status indication setpoint selection1 Byte20.102 HVAC modeCRT
593{{0}}Automatic control deactivation status1 Bit1.3 enableCRT
594{{0}}Heating/Cooling - status indication1 Bit1.100 cooling/heatingCRT
595{{0}}Status indication heating active1 Bit1.11 stateCRT
596{{0}}Status indication cooling active1 Bit1.11 stateCRT
597{{0}}Status indication priority1 Bit1.11 stateCRT
598{{0}}ON/OFF - basic heating1 Bit1.1 switchCRT
598{{0}}ON/OFF1 Bit1.1 switchCRT
599{{0}}Valve position in % - basic heating1 Byte5.1 percentage (0..100%)CRT
599{{0}}Valve position in %1 Byte5.1 percentage (0..100%)CRT
600{{0}}ON/OFF - basic cooling1 Bit1.1 switchCRT
601{{0}}Valve position in % - basic cooling1 Byte5.1 percentage (0..100%)CRT
602{{0}}ON/OFF - additional heating1 Bit1.1 switchCRT
602{{0}}ON/OFF - additional1 Bit1.1 switchCRT
603{{0}}Valve position in % - additional heating1 Byte5.1 percentage (0..100%)CRT
603{{0}}Valve position in % - additional1 Byte5.1 percentage (0..100%)CRT
604{{0}}ON/OFF - additional cooling1 Bit1.1 switchCRT
605{{0}}Valve position in % - additional cooling1 Byte5.1 percentage (0..100%)CRT
606{{0}}Room temperature 12 Bytes9.1 temperature (°C)CWTU
607{{0}}Room temperature 22 Bytes9.1 temperature (°C)CWTU
608{{0}}Room temperature 32 Bytes9.1 temperature (°C)CWTU
609{{0}}Floor temperature2 Bytes9.1 temperature (°C)CWTU
610{{0}}Status indication room temperature2 Bytes9.1 temperature (°C)CRT
611{{0}}Room temperature failure1 Bit1.5 alarmCRT
612{{0}}Minimum room temperature1 Bit1.5 alarmCRT
613{{0}}Maximum room temperature1 Bit1.5 alarmCRT
614{{0}}Ventilation automatic/manual mode1 Bit1.1 switchCWTU
615{{0}}Status ventilation step 1-61 Byte5.10 counter pulses (0..255)CWTU
616{{0}}Status ventilation step 11 Bit1.1 switchCWTU
617{{0}}Status ventilation step 21 Bit1.1 switchCWTU
618{{0}}Status ventilation step 31 Bit1.1 switchCWTU
619{{0}}Status ventilation step 41 Bit1.1 switchCWTU
620{{0}}Status ventilation step 51 Bit1.1 switchCWTU
621{{0}}Status ventilation step 61 Bit1.1 switchCWTU
622{{0}}Ventilation step 1-61 Byte5.10 counter pulses (0..255)CRT
623{{0}}Ventilation step 11 Bit1.1 switchCRT
624{{0}}Ventilation step 21 Bit1.1 switchCRT
625{{0}}Ventilation step 31 Bit1.1 switchCRT
626{{0}}Ventilation step 41 Bit1.1 switchCRT
627{{0}}Ventilation step 51 Bit1.1 switchCRT
628{{0}}Ventilation step 61 Bit1.1 switchCRT
629{{0}}Comfort setpoint heating2 Bytes9.1 temperature (°C)CWTU
629{{0}}Comfort setpoint2 Bytes9.1 temperature (°C)CWTU
629{{0}}Reference setpoint2 Bytes9.1 temperature (°C)CWTU
630{{0}}Standby setpoint heating2 Bytes9.1 temperature (°C)CWTU
631{{0}}Night setpoint heating2 Bytes9.1 temperature (°C)CWTU
632{{0}}Frost protection setpoint heating2 Bytes9.1 temperature (°C)CWTU
633{{0}}Setpoints heating8 BytesCWTU
634{{0}}Comfort setpoint cooling2 Bytes9.1 temperature (°C)CWTU
635{{0}}Standby setpoint cooling2 Bytes9.1 temperature (°C)CWTU
636{{0}}Night setpoint cooling2 Bytes9.1 temperature (°C)CWTU
637{{0}}Heat protection setpoint cooling2 Bytes9.1 temperature (°C)CWTU
638{{0}}Setpoints cooling8 BytesCWTU
639{{0}}Setpoint shift2 Bytes9.2 temperature difference (K)CWTU
640{{0}}Current setpoint2 Bytes9.1 temperature (°C)CWTU
641{{0}}Status indication setpoint shift2 Bytes9.2 temperature difference (K)CRT
642{{0}}Status indication reference setpoint2 Bytes9.1 temperature (°C)CRT
643{{0}}Status indication comfort setpoint heating2 Bytes9.1 temperature (°C)CRT
644{{0}}Status indication standby setpoint heating2 Bytes9.1 temperature (°C)CRT
645{{0}}Status indication night setpoint heating2 Bytes9.1 temperature (°C)CRT
646{{0}}Status indication frost protection setpoint heating2 Bytes9.1 temperature (°C)CRT
647{{0}}Status indication setpoints heating8 BytesCRT
648{{0}}Status indication comfort setpoint cooling2 Bytes9.1 temperature (°C)CRT
649{{0}}Status indication standby setpoint cooling2 Bytes9.1 temperature (°C)CRT
650{{0}}Status indication night setpoint cooling2 Bytes9.1 temperature (°C)CRT
651{{0}}Status indication heat protection setpoint cooling2 Bytes9.1 temperature (°C)CRT
652{{0}}Status indication setpoints cooling8 BytesCRT
653{{0}}Status current setpoint2 Bytes9.1 temperature (°C)CRT
654{{0}}Presence1 Bit1.1 switchCWTU
655{{0}}Lock-up additional step1 Bit1.1 switchCWTU
656{{0}}Heating deactivation1 Bit1.3 enableCWTU
657{{0}}Cooling deactivation1 Bit1.3 enableCWTU
658{{0}}Heating deactivation status1 Bit1.3 enableCRT
659{{0}}Cooling deactivation status1 Bit1.3 enableCRT
660{{0}}Thermostat deactivation1 Bit1.3 enableCWTU
661{{0}}Status indication thermostat deactivation1 Bit1.3 enableCRT
662{{0}}Timer1 Bit1.10 start/stopCWTU
663{{0}}Timer duration3 Bytes10.1 time of dayCWTU
664{{0}}Timer setpoint selection1 Byte20.102 HVAC modeCWTU
665{{0}}Preset 11 Bit1.3 enableCWTU
666{{0}}Preset 21 Bit1.3 enableCWTU
667{{0}}Preset 1 authorization1 Bit1.3 enableCWTU
668{{0}}Preset 2 authorization1 Bit1.3 enableCWTU
669{{0}}Lock-up 11 Bit1.3 enableCWTU
670{{0}}Lock-up 21 Bit1.3 enableCWTU
671{{0}}Status indication lock-up1 Bit1.3 enableCRT
672{{0}}Valve protection date3 Bytes11.1 dateCWTU
673{{0}}Valve protection time3 Bytes10.1 time of dayCWTU
674{{0}}Valve protection date and time8 Bytes19.1 date timeCWTU
675{{0}}Valve protection duration2 Bytes7.6 time (min)CWTU
676{{0}}Valve protection periodicity2 Bytes7.7 time (h)CWTU
677{{0}}Valve protection start/stop1 Bit1.10 start/stopCWTU
678{{0}}Setpoint selection1 Byte20.102 HVAC modeCWTU
679{{0}}Comfort1 Bit1.1 switchCWTU
680{{0}}Standby mode1 Bit1.1 switchCWTU
681{{0}}Night setpoint1 Bit1.1 switchCWTU
682{{0}}Frost/heat protection1 Bit1.1 switchCWTU
683{{0}}Setpoint selection automatic control1 Byte20.102 HVAC modeCWTU
684{{0}}Automatic control deactivation1 Bit1.3 enableCWTU
685{{0}}Heating/Cooling - changeover1 Bit1.100 cooling/heatingCWTU
686{{0}}Priority2 Bit2.2 boolean controlCWTU
687{{0}}Priority1 Bit1.11 stateCWTU
688{{0}}Priority1 Byte20.102 HVAC modeCWTU
689{{0}}Windows contact1 Bit1.19 window/doorCWTU
690{{0}}Scene1 Byte18.1 scene controlCWTU
691{{0}}Status indication setpoint selection1 Byte20.102 HVAC modeCRT
692{{0}}Automatic control deactivation status1 Bit1.3 enableCRT
693{{0}}Heating/Cooling - status indication1 Bit1.100 cooling/heatingCRT
694{{0}}Status indication heating active1 Bit1.11 stateCRT
695{{0}}Status indication cooling active1 Bit1.11 stateCRT
696{{0}}Status indication priority1 Bit1.11 stateCRT
697{{0}}ON/OFF - basic heating1 Bit1.1 switchCRT
697{{0}}ON/OFF1 Bit1.1 switchCRT
698{{0}}Valve position in % - basic heating1 Byte5.1 percentage (0..100%)CRT
698{{0}}Valve position in %1 Byte5.1 percentage (0..100%)CRT
699{{0}}ON/OFF - basic cooling1 Bit1.1 switchCRT
700{{0}}Valve position in % - basic cooling1 Byte5.1 percentage (0..100%)CRT
701{{0}}ON/OFF - additional heating1 Bit1.1 switchCRT
701{{0}}ON/OFF - additional1 Bit1.1 switchCRT
702{{0}}Valve position in % - additional heating1 Byte5.1 percentage (0..100%)CRT
702{{0}}Valve position in % - additional1 Byte5.1 percentage (0..100%)CRT
703{{0}}ON/OFF - additional cooling1 Bit1.1 switchCRT
704{{0}}Valve position in % - additional cooling1 Byte5.1 percentage (0..100%)CRT
705{{0}}Room temperature 12 Bytes9.1 temperature (°C)CWTU
706{{0}}Room temperature 22 Bytes9.1 temperature (°C)CWTU
707{{0}}Room temperature 32 Bytes9.1 temperature (°C)CWTU
708{{0}}Floor temperature2 Bytes9.1 temperature (°C)CWTU
709{{0}}Status indication room temperature2 Bytes9.1 temperature (°C)CRT
710{{0}}Room temperature failure1 Bit1.5 alarmCRT
711{{0}}Minimum room temperature1 Bit1.5 alarmCRT
712{{0}}Maximum room temperature1 Bit1.5 alarmCRT
713{{0}}Ventilation automatic/manual mode1 Bit1.1 switchCWTU
714{{0}}Status ventilation step 1-61 Byte5.10 counter pulses (0..255)CWTU
715{{0}}Status ventilation step 11 Bit1.1 switchCWTU
716{{0}}Status ventilation step 21 Bit1.1 switchCWTU
717{{0}}Status ventilation step 31 Bit1.1 switchCWTU
718{{0}}Status ventilation step 41 Bit1.1 switchCWTU
719{{0}}Status ventilation step 51 Bit1.1 switchCWTU
720{{0}}Status ventilation step 61 Bit1.1 switchCWTU
721{{0}}Ventilation step 1-61 Byte5.10 counter pulses (0..255)CRT
722{{0}}Ventilation step 11 Bit1.1 switchCRT
723{{0}}Ventilation step 21 Bit1.1 switchCRT
724{{0}}Ventilation step 31 Bit1.1 switchCRT
725{{0}}Ventilation step 41 Bit1.1 switchCRT
726{{0}}Ventilation step 51 Bit1.1 switchCRT
727{{0}}Ventilation step 61 Bit1.1 switchCRT
728{{0}}Comfort setpoint heating2 Bytes9.1 temperature (°C)CWTU
728{{0}}Comfort setpoint2 Bytes9.1 temperature (°C)CWTU
728{{0}}Reference setpoint2 Bytes9.1 temperature (°C)CWTU
729{{0}}Standby setpoint heating2 Bytes9.1 temperature (°C)CWTU
730{{0}}Night setpoint heating2 Bytes9.1 temperature (°C)CWTU
731{{0}}Frost protection setpoint heating2 Bytes9.1 temperature (°C)CWTU
732{{0}}Setpoints heating8 BytesCWTU
733{{0}}Comfort setpoint cooling2 Bytes9.1 temperature (°C)CWTU
734{{0}}Standby setpoint cooling2 Bytes9.1 temperature (°C)CWTU
735{{0}}Night setpoint cooling2 Bytes9.1 temperature (°C)CWTU
736{{0}}Heat protection setpoint cooling2 Bytes9.1 temperature (°C)CWTU
737{{0}}Setpoints cooling8 BytesCWTU
738{{0}}Setpoint shift2 Bytes9.2 temperature difference (K)CWTU
739{{0}}Current setpoint2 Bytes9.1 temperature (°C)CWTU
740{{0}}Status indication setpoint shift2 Bytes9.2 temperature difference (K)CRT
741{{0}}Status indication reference setpoint2 Bytes9.1 temperature (°C)CRT
742{{0}}Status indication comfort setpoint heating2 Bytes9.1 temperature (°C)CRT
743{{0}}Status indication standby setpoint heating2 Bytes9.1 temperature (°C)CRT
744{{0}}Status indication night setpoint heating2 Bytes9.1 temperature (°C)CRT
745{{0}}Status indication frost protection setpoint heating2 Bytes9.1 temperature (°C)CRT
746{{0}}Status indication setpoints heating8 BytesCRT
747{{0}}Status indication comfort setpoint cooling2 Bytes9.1 temperature (°C)CRT
748{{0}}Status indication standby setpoint cooling2 Bytes9.1 temperature (°C)CRT
749{{0}}Status indication night setpoint cooling2 Bytes9.1 temperature (°C)CRT
750{{0}}Status indication heat protection setpoint cooling2 Bytes9.1 temperature (°C)CRT
751{{0}}Status indication setpoints cooling8 BytesCRT
752{{0}}Status current setpoint2 Bytes9.1 temperature (°C)CRT
753{{0}}Presence1 Bit1.1 switchCWTU
754{{0}}Lock-up additional step1 Bit1.1 switchCWTU
755{{0}}Heating deactivation1 Bit1.3 enableCWTU
756{{0}}Cooling deactivation1 Bit1.3 enableCWTU
757{{0}}Heating deactivation status1 Bit1.3 enableCRT
758{{0}}Cooling deactivation status1 Bit1.3 enableCRT
759{{0}}Thermostat deactivation1 Bit1.3 enableCWTU
760{{0}}Status indication thermostat deactivation1 Bit1.3 enableCRT
761{{0}}Timer1 Bit1.10 start/stopCWTU
762{{0}}Timer duration3 Bytes10.1 time of dayCWTU
763{{0}}Timer setpoint selection1 Byte20.102 HVAC modeCWTU
764{{0}}Preset 11 Bit1.3 enableCWTU
765{{0}}Preset 21 Bit1.3 enableCWTU
766{{0}}Preset 1 authorization1 Bit1.3 enableCWTU
767{{0}}Preset 2 authorization1 Bit1.3 enableCWTU
768{{0}}Lock-up 11 Bit1.3 enableCWTU
769{{0}}Lock-up 21 Bit1.3 enableCWTU
770{{0}}Status indication lock-up1 Bit1.3 enableCRT
771{{0}}Valve protection date3 Bytes11.1 dateCWTU
772{{0}}Valve protection time3 Bytes10.1 time of dayCWTU
773{{0}}Valve protection date and time8 Bytes19.1 date timeCWTU
774{{0}}Valve protection duration2 Bytes7.6 time (min)CWTU
775{{0}}Valve protection periodicity2 Bytes7.7 time (h)CWTU
776{{0}}Valve protection start/stop1 Bit1.10 start/stopCWTU
777{{0}}Setpoint selection1 Byte20.102 HVAC modeCWTU
778{{0}}Comfort1 Bit1.1 switchCWTU
779{{0}}Standby mode1 Bit1.1 switchCWTU
780{{0}}Night setpoint1 Bit1.1 switchCWTU
781{{0}}Frost/heat protection1 Bit1.1 switchCWTU
782{{0}}Setpoint selection automatic control1 Byte20.102 HVAC modeCWTU
783{{0}}Automatic control deactivation1 Bit1.3 enableCWTU
784{{0}}Heating/Cooling - changeover1 Bit1.100 cooling/heatingCWTU
785{{0}}Priority2 Bit2.2 boolean controlCWTU
786{{0}}Priority1 Bit1.11 stateCWTU
787{{0}}Priority1 Byte20.102 HVAC modeCWTU
788{{0}}Windows contact1 Bit1.19 window/doorCWTU
789{{0}}Scene1 Byte18.1 scene controlCWTU
790{{0}}Status indication setpoint selection1 Byte20.102 HVAC modeCRT
791{{0}}Automatic control deactivation status1 Bit1.3 enableCRT
792{{0}}Heating/Cooling - status indication1 Bit1.100 cooling/heatingCRT
793{{0}}Status indication heating active1 Bit1.11 stateCRT
794{{0}}Status indication cooling active1 Bit1.11 stateCRT
795{{0}}Status indication priority1 Bit1.11 stateCRT
796{{0}}ON/OFF - basic heating1 Bit1.1 switchCRT
796{{0}}ON/OFF1 Bit1.1 switchCRT
797{{0}}Valve position in % - basic heating1 Byte5.1 percentage (0..100%)CRT
797{{0}}Valve position in %1 Byte5.1 percentage (0..100%)CRT
798{{0}}ON/OFF - basic cooling1 Bit1.1 switchCRT
799{{0}}Valve position in % - basic cooling1 Byte5.1 percentage (0..100%)CRT
800{{0}}ON/OFF - additional heating1 Bit1.1 switchCRT
800{{0}}ON/OFF - additional1 Bit1.1 switchCRT
801{{0}}Valve position in % - additional heating1 Byte5.1 percentage (0..100%)CRT
801{{0}}Valve position in % - additional1 Byte5.1 percentage (0..100%)CRT
802{{0}}ON/OFF - additional cooling1 Bit1.1 switchCRT
803{{0}}Valve position in % - additional cooling1 Byte5.1 percentage (0..100%)CRT
804{{0}}Room temperature 12 Bytes9.1 temperature (°C)CWTU
805{{0}}Room temperature 22 Bytes9.1 temperature (°C)CWTU
806{{0}}Room temperature 32 Bytes9.1 temperature (°C)CWTU
807{{0}}Floor temperature2 Bytes9.1 temperature (°C)CWTU
808{{0}}Status indication room temperature2 Bytes9.1 temperature (°C)CRT
809{{0}}Room temperature failure1 Bit1.5 alarmCRT
810{{0}}Minimum room temperature1 Bit1.5 alarmCRT
811{{0}}Maximum room temperature1 Bit1.5 alarmCRT
812{{0}}Ventilation automatic/manual mode1 Bit1.1 switchCWTU
813{{0}}Status ventilation step 1-61 Byte5.10 counter pulses (0..255)CWTU
814{{0}}Status ventilation step 11 Bit1.1 switchCWTU
815{{0}}Status ventilation step 21 Bit1.1 switchCWTU
816{{0}}Status ventilation step 31 Bit1.1 switchCWTU
817{{0}}Status ventilation step 41 Bit1.1 switchCWTU
818{{0}}Status ventilation step 51 Bit1.1 switchCWTU
819{{0}}Status ventilation step 61 Bit1.1 switchCWTU
820{{0}}Ventilation step 1-61 Byte5.10 counter pulses (0..255)CRT
821{{0}}Ventilation step 11 Bit1.1 switchCRT
822{{0}}Ventilation step 21 Bit1.1 switchCRT
823{{0}}Ventilation step 31 Bit1.1 switchCRT
824{{0}}Ventilation step 41 Bit1.1 switchCRT
825{{0}}Ventilation step 51 Bit1.1 switchCRT
826{{0}}Ventilation step 61 Bit1.1 switchCRT
827{{0}}Comfort setpoint heating2 Bytes9.1 temperature (°C)CWTU
827{{0}}Comfort setpoint2 Bytes9.1 temperature (°C)CWTU
827{{0}}Reference setpoint2 Bytes9.1 temperature (°C)CWTU
828{{0}}Standby setpoint heating2 Bytes9.1 temperature (°C)CWTU
829{{0}}Night setpoint heating2 Bytes9.1 temperature (°C)CWTU
830{{0}}Frost protection setpoint heating2 Bytes9.1 temperature (°C)CWTU
831{{0}}Setpoints heating8 BytesCWTU
832{{0}}Comfort setpoint cooling2 Bytes9.1 temperature (°C)CWTU
833{{0}}Standby setpoint cooling2 Bytes9.1 temperature (°C)CWTU
834{{0}}Night setpoint cooling2 Bytes9.1 temperature (°C)CWTU
835{{0}}Heat protection setpoint cooling2 Bytes9.1 temperature (°C)CWTU
836{{0}}Setpoints cooling8 BytesCWTU
837{{0}}Setpoint shift2 Bytes9.2 temperature difference (K)CWTU
838{{0}}Current setpoint2 Bytes9.1 temperature (°C)CWTU
839{{0}}Status indication setpoint shift2 Bytes9.2 temperature difference (K)CRT
840{{0}}Status indication reference setpoint2 Bytes9.1 temperature (°C)CRT
841{{0}}Status indication comfort setpoint heating2 Bytes9.1 temperature (°C)CRT
842{{0}}Status indication standby setpoint heating2 Bytes9.1 temperature (°C)CRT
843{{0}}Status indication night setpoint heating2 Bytes9.1 temperature (°C)CRT
844{{0}}Status indication frost protection setpoint heating2 Bytes9.1 temperature (°C)CRT
845{{0}}Status indication setpoints heating8 BytesCRT
846{{0}}Status indication comfort setpoint cooling2 Bytes9.1 temperature (°C)CRT
847{{0}}Status indication standby setpoint cooling2 Bytes9.1 temperature (°C)CRT
848{{0}}Status indication night setpoint cooling2 Bytes9.1 temperature (°C)CRT
849{{0}}Status indication heat protection setpoint cooling2 Bytes9.1 temperature (°C)CRT
850{{0}}Status indication setpoints cooling8 BytesCRT
851{{0}}Status current setpoint2 Bytes9.1 temperature (°C)CRT
852{{0}}Presence1 Bit1.1 switchCWTU
853{{0}}Lock-up additional step1 Bit1.1 switchCWTU
854{{0}}Heating deactivation1 Bit1.3 enableCWTU
855{{0}}Cooling deactivation1 Bit1.3 enableCWTU
856{{0}}Heating deactivation status1 Bit1.3 enableCRT
857{{0}}Cooling deactivation status1 Bit1.3 enableCRT
858{{0}}Thermostat deactivation1 Bit1.3 enableCWTU
859{{0}}Status indication thermostat deactivation1 Bit1.3 enableCRT
860{{0}}Timer1 Bit1.10 start/stopCWTU
861{{0}}Timer duration3 Bytes10.1 time of dayCWTU
862{{0}}Timer setpoint selection1 Byte20.102 HVAC modeCWTU
863{{0}}Preset 11 Bit1.3 enableCWTU
864{{0}}Preset 21 Bit1.3 enableCWTU
865{{0}}Preset 1 authorization1 Bit1.3 enableCWTU
866{{0}}Preset 2 authorization1 Bit1.3 enableCWTU
867{{0}}Lock-up 11 Bit1.3 enableCWTU
868{{0}}Lock-up 21 Bit1.3 enableCWTU
869{{0}}Status indication lock-up1 Bit1.3 enableCRT
870{{0}}Valve protection date3 Bytes11.1 dateCWTU
871{{0}}Valve protection time3 Bytes10.1 time of dayCWTU
872{{0}}Valve protection date and time8 Bytes19.1 date timeCWTU
873{{0}}Valve protection duration2 Bytes7.6 time (min)CWTU
874{{0}}Valve protection periodicity2 Bytes7.7 time (h)CWTU
875{{0}}Valve protection start/stop1 Bit1.10 start/stopCWTU
876{{0}}Setpoint selection1 Byte20.102 HVAC modeCWTU
877{{0}}Comfort1 Bit1.1 switchCWTU
878{{0}}Standby mode1 Bit1.1 switchCWTU
879{{0}}Night setpoint1 Bit1.1 switchCWTU
880{{0}}Frost/heat protection1 Bit1.1 switchCWTU
881{{0}}Setpoint selection automatic control1 Byte20.102 HVAC modeCWTU
882{{0}}Automatic control deactivation1 Bit1.3 enableCWTU
883{{0}}Heating/Cooling - changeover1 Bit1.100 cooling/heatingCWTU
884{{0}}Priority2 Bit2.2 boolean controlCWTU
885{{0}}Priority1 Bit1.11 stateCWTU
886{{0}}Priority1 Byte20.102 HVAC modeCWTU
887{{0}}Windows contact1 Bit1.19 window/doorCWTU
888{{0}}Scene1 Byte18.1 scene controlCWTU
889{{0}}Status indication setpoint selection1 Byte20.102 HVAC modeCRT
890{{0}}Automatic control deactivation status1 Bit1.3 enableCRT
891{{0}}Heating/Cooling - status indication1 Bit1.100 cooling/heatingCRT
892{{0}}Status indication heating active1 Bit1.11 stateCRT
893{{0}}Status indication cooling active1 Bit1.11 stateCRT
894{{0}}Status indication priority1 Bit1.11 stateCRT
895{{0}}ON/OFF - basic heating1 Bit1.1 switchCRT
895{{0}}ON/OFF1 Bit1.1 switchCRT
896{{0}}Valve position in % - basic heating1 Byte5.1 percentage (0..100%)CRT
896{{0}}Valve position in %1 Byte5.1 percentage (0..100%)CRT
897{{0}}ON/OFF - basic cooling1 Bit1.1 switchCRT
898{{0}}Valve position in % - basic cooling1 Byte5.1 percentage (0..100%)CRT
899{{0}}ON/OFF - additional heating1 Bit1.1 switchCRT
899{{0}}ON/OFF - additional1 Bit1.1 switchCRT
900{{0}}Valve position in % - additional heating1 Byte5.1 percentage (0..100%)CRT
900{{0}}Valve position in % - additional1 Byte5.1 percentage (0..100%)CRT
901{{0}}ON/OFF - additional cooling1 Bit1.1 switchCRT
902{{0}}Valve position in % - additional cooling1 Byte5.1 percentage (0..100%)CRT
903{{0}}Room temperature 12 Bytes9.1 temperature (°C)CWTU
904{{0}}Room temperature 22 Bytes9.1 temperature (°C)CWTU
905{{0}}Room temperature 32 Bytes9.1 temperature (°C)CWTU
906{{0}}Floor temperature2 Bytes9.1 temperature (°C)CWTU
907{{0}}Status indication room temperature2 Bytes9.1 temperature (°C)CRT
908{{0}}Room temperature failure1 Bit1.5 alarmCRT
909{{0}}Minimum room temperature1 Bit1.5 alarmCRT
910{{0}}Maximum room temperature1 Bit1.5 alarmCRT
911{{0}}Ventilation automatic/manual mode1 Bit1.1 switchCWTU
912{{0}}Status ventilation step 1-61 Byte5.10 counter pulses (0..255)CWTU
913{{0}}Status ventilation step 11 Bit1.1 switchCWTU
914{{0}}Status ventilation step 21 Bit1.1 switchCWTU
915{{0}}Status ventilation step 31 Bit1.1 switchCWTU
916{{0}}Status ventilation step 41 Bit1.1 switchCWTU
917{{0}}Status ventilation step 51 Bit1.1 switchCWTU
918{{0}}Status ventilation step 61 Bit1.1 switchCWTU
919{{0}}Ventilation step 1-61 Byte5.10 counter pulses (0..255)CRT
920{{0}}Ventilation step 11 Bit1.1 switchCRT
921{{0}}Ventilation step 21 Bit1.1 switchCRT
922{{0}}Ventilation step 31 Bit1.1 switchCRT
923{{0}}Ventilation step 41 Bit1.1 switchCRT
924{{0}}Ventilation step 51 Bit1.1 switchCRT
925{{0}}Ventilation step 61 Bit1.1 switchCRT
926{{0}}Comfort setpoint heating2 Bytes9.1 temperature (°C)CWTU
926{{0}}Comfort setpoint2 Bytes9.1 temperature (°C)CWTU
926{{0}}Reference setpoint2 Bytes9.1 temperature (°C)CWTU
927{{0}}Standby setpoint heating2 Bytes9.1 temperature (°C)CWTU
928{{0}}Night setpoint heating2 Bytes9.1 temperature (°C)CWTU
929{{0}}Frost protection setpoint heating2 Bytes9.1 temperature (°C)CWTU
930{{0}}Setpoints heating8 BytesCWTU
931{{0}}Comfort setpoint cooling2 Bytes9.1 temperature (°C)CWTU
932{{0}}Standby setpoint cooling2 Bytes9.1 temperature (°C)CWTU
933{{0}}Night setpoint cooling2 Bytes9.1 temperature (°C)CWTU
934{{0}}Heat protection setpoint cooling2 Bytes9.1 temperature (°C)CWTU
935{{0}}Setpoints cooling8 BytesCWTU
936{{0}}Setpoint shift2 Bytes9.2 temperature difference (K)CWTU
937{{0}}Current setpoint2 Bytes9.1 temperature (°C)CWTU
938{{0}}Status indication setpoint shift2 Bytes9.2 temperature difference (K)CRT
939{{0}}Status indication reference setpoint2 Bytes9.1 temperature (°C)CRT
940{{0}}Status indication comfort setpoint heating2 Bytes9.1 temperature (°C)CRT
941{{0}}Status indication standby setpoint heating2 Bytes9.1 temperature (°C)CRT
942{{0}}Status indication night setpoint heating2 Bytes9.1 temperature (°C)CRT
943{{0}}Status indication frost protection setpoint heating2 Bytes9.1 temperature (°C)CRT
944{{0}}Status indication setpoints heating8 BytesCRT
945{{0}}Status indication comfort setpoint cooling2 Bytes9.1 temperature (°C)CRT
946{{0}}Status indication standby setpoint cooling2 Bytes9.1 temperature (°C)CRT
947{{0}}Status indication night setpoint cooling2 Bytes9.1 temperature (°C)CRT
948{{0}}Status indication heat protection setpoint cooling2 Bytes9.1 temperature (°C)CRT
949{{0}}Status indication setpoints cooling8 BytesCRT
950{{0}}Status current setpoint2 Bytes9.1 temperature (°C)CRT
951{{0}}Presence1 Bit1.1 switchCWTU
952{{0}}Lock-up additional step1 Bit1.1 switchCWTU
953{{0}}Heating deactivation1 Bit1.3 enableCWTU
954{{0}}Cooling deactivation1 Bit1.3 enableCWTU

First 1000 of 1461 group objects shown. Download the .knxprod for the full list.

Parameters (583)
ParameterTypeDefault
Authorization object logic blocklistNot active
Value at initializationlistValue before initialization
Polaritylist0 = Locked-up , 1 = Authorized
Logic function typelistOR
Logic result after authorisationlistImmediate emission when authorization
Emission of logic resultlistBy logic result value change
Number of logic inputslist1
Value at initialization of logic input 1listValue before initialization
Value at initialization of logic input 2listValue before initialization
Value at initialization of logic input 3listValue before initialization
Value at initialization of logic input 4listValue before initialization
Inverting value of logic input 1listMaintain status
Inverting value of logic input 2listMaintain status
Inverting value of logic input 3listMaintain status
Inverting value of logic input 4listMaintain status
Logic result acts on thermostatslistNo
Action if logic result = 0listAuto
Action if logic result = 1listAuto
Thermostat 1listNot active
Thermostat 2listNot active
Thermostat 3listNot active
Thermostat 4listNot active
Thermostat 5listNot active
Thermostat 6listNot active
Thermostat 7listNot active
Thermostat 8listNot active
Thermostat 9listNot active
Thermostat 10listNot active
Thermostat 11listNot active
Thermostat 12listNot active
Manual modelistActive
Object deactivation of manual modelistNot active
Polaritylist0=Manual mode locked-up, 1=Manual mode authorized
Object status indication manual modelistNot active
Polaritylist0=Manual mode deactivated, 1=Manual mode activated
PolaritylistActive
Duration of manual mode activationtime30
EmissionlistOn status change
Summer/winter changeover modelistBy date
Polaritylist1 = Summer, 0 = Winter
Summer/winter mode after ETS downloadlistNo change
Behaviour after service modelistTheoretical status without service mode
Emission periodtime1800
Polaritylist0 = Always OFF, 1 = Status indication
Device LED switch off objectlistNo
Status indicationlistActive
Service modelistNo
Device diagnosis objectlistNo
Logic block 1listNot active
Logic block 2listNot active
Summer/winter mode changeoverlistNo
Outputs parameters settingslistIndividual configuration
Number of used thermostatslist12 thermostats
Number of used outputslist6 outputs
Output 1 nametextOutput 1
Output 2 nametextOutput 2
Output 3 nametextOutput 3
Output 4 nametextOutput 4
Output 5 nametextOutput 5
Output 6 nametextOutput 6
Default valve statuslistNormally closed
Status after bus power cutlistValue as emergency
Behaviour after ETS downloadlistSpecific command value
Hours counterlistNot active
Output accounted for pump controllistYes
Output accounted for heating requirementlistYes
Output accounted for largest command valuelistYes
Output accounted for service modelistYes
Output accounted for manual modelistYes
Emission during manual modelistNot active
Hours counter directionlistIncrement
Hours counter setpointsignedInt 0…2147483647235926000
Counter setpoint value modifiable through objectlistNot active
Hours counter objects unitlistSeconds
EmissionlistPeriodically
Periodical emission delaytime1800
Value intervalunsignedInt 0…655351
EmissionlistOn status change and periodically
Valve protectionlistActive
Valve protection activationlistPeriodically
Polaritylist1 = Start, 0 = Stop
Smart valve protectionlistYes
Limiting value min. command valueunsignedInt 0…255204
PeriodicitylistEvery week
CH1_ValveRinsingDatedate2018-01-24
Timetime0
Lock-up durationlistPermanently
Polarity of lock-up object 1list0 = Lock-up deactivated, 1 = Lock-up activated
Polarity of lock-up object 2list0 = Lock-up deactivated, 1 = Lock-up activated
Priority between lock-up 1 and lock-up 2unsignedInt 0…2551
Status if lock-up 1listMaintain status
Status if lock-up 2listMaintain status
Status after lock-up function 1listMaintain status
Status after lock-up function 2listMaintain status
Activation of lock-up status objectlistNot active
Polaritylist0 = Lock-up deactivated, 1 = Lock-up activated
Emission periodtime600
Cycle time for continous control with PWMtime900
Thermostat 1 nametextThermostat 1
Thermostat 2 nametextThermostat 2
Thermostat 3 nametextThermostat 3
Thermostat 4 nametextThermostat 4
Thermostat 5 nametextThermostat 5
Thermostat 6 nametextThermostat 6
Thermostat 7 nametextThermostat 7
Thermostat 8 nametextThermostat 8
Thermostat 9 nametextThermostat 9
Thermostat 10 nametextThermostat 10
Thermostat 11 nametextThermostat 11
Thermostat 12 nametextThermostat 12
Function selectionlistHeating
Ventilation availableunsignedInt 0…10
Emission valve position heating and cooling to one common objectunsignedInt 0…11
Status after resetlistStatus before reset
Heating/Cooling - changeoverlistThrough object
Heat/cool mode after resetlistOperating mode before reset
Thermostat deactivationlistNo
Valve protectionlistHeating/Cooling
ThresholdunsignedInt 0…255204
Type of heating controllistSwitching PI-control (PWM)
Cycle timelist15 min
Proportional rangelist3,0K
Integration timelist30 min
Derivative timelist30 min
PolaritylistNot inverted
Floor temperature limitationunsignedInt 0…11
Ventilation also used for heatingunsignedInt 0…10
Hysteresislist+/-0,5K
Hysteresis durationlist5 min
Type of heating equipmentlistWarm water heating
Mode selectionlistThrough value (1 byte)
Presence detectionunsignedInt 0…10
Comfort lengthening timetime30
Floor temperature limitationunsignedInt 0…10
Type of cooling controllistSwitching PI-control (PWM)
Ventilation also used for coolingunsignedInt 0…10
Hysteresislist+/-0,3K
Type of cooling equipmentlistCooling ceiling
Room temperature detectionlistThrough 1 object
Timeout of room temperaturetime45
Temperature 1 weightingunsignedInt 1…10050
Temperature 2 weightingunsignedInt 1…10050
Temperature 3 weightingunsignedInt 1…10050
Floor temperature detectionlistYes
Timeout of floor temperaturetime45
Maximum floor temperatureunsignedInt 24…4628
Value emission by variation oflist0,5K
Emission room temperature alarm through objectsunsignedInt 0…10
Minimum room temperatureunsignedInt 0…407
Maximum room temperatureunsignedInt 0…4035
Ventilation objectlistValue object (1 byte)
Number of ventilation stepslist3 steps
Start ventilation step 1 byunsignedInt 0…1001
Start ventilation step 2 byunsignedInt 0…10020
Start ventilation step 3 byunsignedInt 0…10040
Start ventilation step 4 byunsignedInt 0…10060
Start ventilation step 5 byunsignedInt 0…10080
Start ventilation step 6 byunsignedInt 0…10090
HysteresisunsignedInt 0…1003
Timing between ventilation stepunsignedInt 0…2552
Overrun time heatingunsignedInt 0…2550
Overrun time coolingunsignedInt 0…2550
Value emission by variation ofunsignedInt 0…1003
Setpoints presetlistAbsolute (independent setpoint)
Comfort setpoint heatingunsignedInt 7…4021
Frost protection setpoint heatingunsignedInt 7…407
Heat protection setpoint coolingunsignedInt 7…4035
Comfort setpointunsignedInt 7…4021
Setpoint objectslistCombined
Difference between basic and additional stagesunsignedInt 1…202
Maximum setpointunsignedInt 1…203
Minimum setpointunsignedInt 1…203
Save changes permanentlyunsignedInt 0…10
Number of scenes usedunsignedInt 0…648
Scenes memorisation by long key pressunsignedInt 0…11
Scene 1unsignedInt 0…11
Scene 2unsignedInt 0…11
Scene 3unsignedInt 0…11
Scene 4unsignedInt 0…11
Scene 5unsignedInt 0…11
Scene 6unsignedInt 0…11
Scene 7unsignedInt 0…11
Scene 8unsignedInt 0…11
Scene 9unsignedInt 0…11
Scene 10unsignedInt 0…11
Scene 11unsignedInt 0…11
Scene 12unsignedInt 0…11
Scene 13unsignedInt 0…11
Scene 14unsignedInt 0…11
Scene 15unsignedInt 0…11
Scene 16unsignedInt 0…11
Scene 17unsignedInt 0…11
Scene 18unsignedInt 0…11
Scene 19unsignedInt 0…11
Scene 20unsignedInt 0…11
Scene 21unsignedInt 0…11
Scene 22unsignedInt 0…11
Scene 23unsignedInt 0…11
Scene 24unsignedInt 0…11
Scene 25unsignedInt 0…11
Scene 26unsignedInt 0…11
Scene 27unsignedInt 0…11
Scene 28unsignedInt 0…11
Scene 29unsignedInt 0…11
Scene 30unsignedInt 0…11
Scene 31unsignedInt 0…11
Scene 32unsignedInt 0…11
Scene 33unsignedInt 0…11
Scene 34unsignedInt 0…11
Scene 35unsignedInt 0…11
Scene 36unsignedInt 0…11
Scene 37unsignedInt 0…11
Scene 38unsignedInt 0…11
Scene 39unsignedInt 0…11
Scene 40unsignedInt 0…11
Scene 41unsignedInt 0…11
Scene 42unsignedInt 0…11
Scene 43unsignedInt 0…11
Scene 44unsignedInt 0…11
Scene 45unsignedInt 0…11
Scene 46unsignedInt 0…11
Scene 47unsignedInt 0…11
Scene 48unsignedInt 0…11
Scene 49unsignedInt 0…11
Scene 50unsignedInt 0…11
Scene 51unsignedInt 0…11
Scene 52unsignedInt 0…11
Scene 53unsignedInt 0…11
Scene 54unsignedInt 0…11
Scene 55unsignedInt 0…11
Scene 56unsignedInt 0…11
Scene 57unsignedInt 0…11
Scene 58unsignedInt 0…11
Scene 59unsignedInt 0…11
Scene 60unsignedInt 0…11
Scene 61unsignedInt 0…11
Scene 62unsignedInt 0…11
Scene 63unsignedInt 0…11
Scene 64unsignedInt 0…11
Scene 1 setpointlistComfort
Scene 2 setpointlistComfort
Scene 3 setpointlistComfort
Scene 4 setpointlistComfort
Scene 5 setpointlistComfort
Scene 6 setpointlistComfort
Scene 7 setpointlistComfort
Scene 8 setpointlistComfort
Scene 9 setpointlistComfort
Scene 10 setpointlistComfort
Scene 11 setpointlistComfort
Scene 12 setpointlistComfort
Scene 13 setpointlistComfort
Scene 14 setpointlistComfort
Scene 15 setpointlistComfort
Scene 16 setpointlistComfort
Scene 17 setpointlistComfort
Scene 18 setpointlistComfort
Scene 19 setpointlistComfort
Scene 20 setpointlistComfort
Scene 21 setpointlistComfort
Scene 22 setpointlistComfort
Scene 23 setpointlistComfort
Scene 24 setpointlistComfort
Scene 25 setpointlistComfort
Scene 26 setpointlistComfort
Scene 27 setpointlistComfort
Scene 28 setpointlistComfort
Scene 29 setpointlistComfort
Scene 30 setpointlistComfort
Scene 31 setpointlistComfort
Scene 32 setpointlistComfort
Scene 33 setpointlistComfort
Scene 34 setpointlistComfort
Scene 35 setpointlistComfort
Scene 36 setpointlistComfort
Scene 37 setpointlistComfort
Scene 38 setpointlistComfort
Scene 39 setpointlistComfort
Scene 40 setpointlistComfort
Scene 41 setpointlistComfort
Scene 42 setpointlistComfort
Scene 43 setpointlistComfort
Scene 44 setpointlistComfort
Scene 45 setpointlistComfort
Scene 46 setpointlistComfort
Scene 47 setpointlistComfort
Scene 48 setpointlistComfort
Scene 49 setpointlistComfort
Scene 50 setpointlistComfort
Scene 51 setpointlistComfort
Scene 52 setpointlistComfort
Scene 53 setpointlistComfort
Scene 54 setpointlistComfort
Scene 55 setpointlistComfort
Scene 56 setpointlistComfort
Scene 57 setpointlistComfort
Scene 58 setpointlistComfort
Scene 59 setpointlistComfort
Scene 60 setpointlistComfort
Scene 61 setpointlistComfort
Scene 62 setpointlistComfort
Scene 63 setpointlistComfort
Scene 64 setpointlistComfort
TimerunsignedInt 0…10
PriorityunsignedInt 0…10
Automatic controlunsignedInt 0…10
Automatic control deactivationunsignedInt 0…10
SceneunsignedInt 0…10
Preset authorization objectslistNot active
Value of authorization preset 1 at initializationlistValue before initialization
Value of authorization preset 2 at initializationlistValue before initialization
Status if preset 1 object = 0listMaintain status
Status if preset 1 object = 1listMaintain status
Status if preset 2 object = 0listMaintain status
Status if preset 2 object = 1listMaintain status
Timer operationlistComfort
Timer durationtime14400
Timer interruptionlistYes
Timer retriggerabilitylistYes
Timer duration extension (10 first seconds)list6
Timer duration modifiable through objectlistNot active
Setpoint selection during timer modifiable through objectlistNot active
Lock-up typelistOutput lock-up
Mode selectionlistNo
ScenelistNo
TimerlistNo
Setpoint shiftlistNo
Presence/AbsencelistNo
Preset 1listNo
Preset 2listNo
Setpoint selection automatic controllistNo
Priority object formatlist2 bits
Activation of priority status objectlistActive
Polaritylist0 = Not forced, 1 = Forced
Status after prioritylistTheoretical status without priority
Polaritylist0 = deactivated, 1 = activated
Setpoint selection during prioritylistComfort
Emergency power summerunsignedInt 0…25576
Emergency power winterunsignedInt 0…255178
Emergency powerunsignedInt 0…25576
Emergency power summerunsignedInt 0…255178
Emergency powerunsignedInt 0…255178
Emergency power winterunsignedInt 0…25576
PolaritylistON = 1
Lock-up additional steplistNo
Valve protection durationtime10
Object room temperature failure polaritylistNot inverted
Object room temperature lower limit alarm polaritylistNot inverted
Object room temperature upper limit alarm polaritylistNot inverted
Start ventilation step 1 byunsignedInt 0…2552
Start ventilation step 2 byunsignedInt 0…25551
Start ventilation step 3 byunsignedInt 0…255102
Start ventilation step 4 byunsignedInt 0…255153
Start ventilation step 5 byunsignedInt 0…255204
Start ventilation step 6 byunsignedInt 0…255229
Standby setpoint heatingunsignedInt 7…4019
Standby offsetunsignedInt 1…202
Night setpoint coolingunsignedInt 7…4026
Night increaseunsignedInt 0…400
Night setpoint heatingunsignedInt 7…4016
Night offsetunsignedInt 1…205
Standby setpoint coolingunsignedInt 7…4023
Standby increaseunsignedInt 0…400
Comfort setpoint coolingunsignedInt 700…40002100
Difference between heating and coolingunsignedInt 0…400
ScenelistScene 1
ScenelistScene 2
Priority between lock-up 1 and lock-up 2listLock-up 1 > Lock-up 2
YearunsignedInt 0…40951972
MonthlistMarch
Daylist13
HourunsignedInt 0…230
MinutesunsignedInt 0…590
Year-MonthunsignedInt 0…6553510164
Same 2listNot active
Command value formatlistContinous with PWM (1 byte)
Command value monitoringlistYes
Monitoring timetime60
Command value limitationlistNot used
Command value limitation at bus returnlistNo
Command value limitation after ETS downloadlistNo
Minimum command valueunsignedInt 0…2550
Maximum command valueunsignedInt 0…255255
Cmd value if active emergency operation summerunsignedInt 0…25576
Cmd value if active emergency operation winterunsignedInt 0…255178
Command value if active forced position summerunsignedInt 0…25576
Command value if active forced position winterunsignedInt 0…255178
Priority object formatlistNot used
Polaritylist1 = Priority active, 0 = Priority not active
Short circuit/Overload status indicationlistNo
Value intervalunsignedInt 0…655351800
Lock-up valueunsignedInt 0…255255
MinunsignedInt 0…590
Emergency command value in summerunsignedInt 0…10030
Emergency command valueunsignedInt 0…10030
Emergency command value in winterunsignedInt 0…10070
Emergency command value in winterunsignedInt 0…10030
Emergency command value in summerunsignedInt 0…10070
Emergency command valueunsignedInt 0…10070
HysteresisunsignedInt 0…2557
Lock-up durationunsignedInt 0…4294967295900000
Status during deactivationlistFrost/heat protection
Heating deactivation polaritylistON = 1
Cooling deactivation polaritylistON = 1
Date and time request delay at initializationunsignedInt 0…25520
Date and time objectslist1 object (8 bytes)
Activ. of restore ETS-parameters objectlistNot active
Value after ETS programmingunsignedInt 0…2550
Application software versiontext1.1.8
Version of translation filelist11
Response to bus voltage failureunsignedInt 0…2550
SecondsunsignedInt 0…2550
Output 1 controlled bylistExternal thermostat
Output 2 controlled bylistExternal thermostat
Output 3 controlled bylistExternal thermostat
Output 4 controlled bylistExternal thermostat
Output 5 controlled bylistExternal thermostat
Output 6 controlled bylistExternal thermostat
Regulation typelistHeating
CH23_Output1RegulatorslistYes
CH23_Output1UsedlistYes
Polaritylist1 = Failure, 0 = No failure
Valves operating voltage failure objectlistNo
Short circuit/overload reset objectlistNo
Heat requirementlistYes
Polaritylist1 = Heat requirement, 0 = No heat requirement
External heat requirementlistNo
Threshold value for heat requirement sendingunsignedInt 0…1001
Hysteresis value for heat requirement sendingunsignedInt 1…201
Heat requirement activation delaytime300
Heat requirement deactivation delaytime0
Largest command valuelistNo
Value emission by variation ofunsignedInt 0…655357
External largest command valuelistNo
Pump controllistNo
Polaritylist1 = Pump ON, 0 = Pump OFF
External pump controllistNo
Threshold value for pump control sendingunsignedInt 0…1001
Pump activation delaytime300
Pump deactivation delaytime0
Pump protectionlistNo
Pump protection activationlistPeriodically
Smart pump protectionlistYes
Limiting value min. command valueunsignedInt 0…2550
Date of first activation (dd/mm/yyyy)date1972-03-13
Time of first activationtime0
Pump protection durationtime5
Floor temperature detectionlistNo
PresetunsignedInt 0…10
Lock-upunsignedInt 0…10
Start ventilation steplistStep 1
Minimum room temperatureunsignedInt 0…4000700
Maximum room temperatureunsignedInt 0…40003500
Maximum floor temperatureunsignedInt 2400…46002800
Difference between basic and additional stagesunsignedInt 100…2000200
Maximum setpointunsignedInt 100…2000300
Minimum setpointunsignedInt 100…2000300
Comfort setpointunsignedInt 700…40002100
Basic comfort setpointunsignedInt 700…40002100
Frost protection setpoint heatingunsignedInt 700…4000700
Setpoint frost protectionunsignedInt 700…4000700
Heat protection setpoint coolingunsignedInt 700…40003500
Setpoint heat protectionunsignedInt 700…40003500
CH8_SetpointsHeatingOffsetStandbyunsignedInt 100…2000200
CH8_SetpointsHeatingStandbyunsignedInt 700…40001900
CH8_SetpointsHeatingOffsetNightunsignedInt 100…2000500
CH8_SetpointsHeatingNightunsignedInt 700…40001600
Comfort setpoint coolingunsignedInt 700…40002300
CH8_SetpointsDeadZoneunsignedInt 0…40000
Night setpoint coolingunsignedInt 700…40002600
CH8_SetpointsCoolingOffsetNightunsignedInt 0…40000
Dead zone between heating and coolingunsignedInt 0…40000
Comfort setpoint coolingunsignedInt 7…4021
Emission modeunsignedInt 0…655351
Number of lock-up objectslist1
Summer/winter changeover datelistOctober
Winter/summer changeover datelistApril
Manual fan controllistNo
Polaritylist0 = automatic mode, 1 = manual mode
SecunsignedInt 0…590
Priority between lock-up 1 and lock-up 2unsignedInt 0…2550
Limiting value of the command value for opening the valveunsignedInt 0…25525
Hysteresis limiting value for closing the valveunsignedInt 0…25512
Status indication priority objectlistNot active
Command valueunsignedInt 0…1000
Minimum command valueunsignedInt 0…1000
Lock-up valueunsignedInt 0…100100
Maximum command valueunsignedInt 0…100100
Threshold value for valve opening/closingunsignedInt 0…10010
Hysteresis value for valve opening/closingunsignedInt 0…1005
Command value when priority active in winterunsignedInt 0…10070
Command value when priority active in summerunsignedInt 0…10030
Command value when emergency active in summerunsignedInt 0…10030
Command value when emergency active in winterunsignedInt 0…10070
Command value when priority activeunsignedInt 0…10030
Command value when emergency activeunsignedInt 0…10030
Valve protection minimum commande valueunsignedInt 0…10080
CH1_CommandLimitingValuelistNot active
{{0}}listTheoretical status without service mode
Same 0 1listNot active

First 500 of 583 parameters shown. Download the .knxprod for the full list.

Version history

ApplicationApp noFingerprintFirst seenSizeFile
S75316403 1.1 latest$E0D1CFE12026-11-251.2 MBDownload

About this file

This is the official ETS product database for the Berker Heating actuator 6 channels KNX, with regulation, 24/230V (75316403), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.

More from Berker

All Berker products