Rollladenaktor 4fach REG 75314022
Berker · Order number 75314022 · Blinds/shutters › Blinds/shutters
75314022
Download .knxprod Rolllade 20CD11 1.1 · 99 KB
Product
| Manufacturer | Berker |
|---|---|
| Product name | Rollladenaktor 4fach REG |
| Order number | 75314022 |
| Hardware | REG 2010 Rollladenaktor 4fach REG |
| Medium | Twisted Pair |
| Bus current (mA) | 6 |
| Rail mounted | Yes |
| Width (mm) | 72 |
| Registration | Registered |
| Languages | de-DE |
| Catalog entry | M-0006_H-6.20.2F.2F.2075314022-1-O000A_HP-20CD-11-BE53-O000A_CI-75314022-1 |
| Fingerprint | BE53 |
| SHA-256 | 99c9134bcde1c591e71fe8dc14a4482018e7ba04c02d0deb15583f983b83d14d |
| First seen | 2026-11-25 |
| Markets | 69 markets |
Application program: Rolllade 20CD11 1.1
| Application number | $20CD |
|---|---|
| Version | 1.1 |
| Mask version | MV-0705 (7.5) |
| KNX Data Secure | No |
| Minimum ETS version | 3.0d |
| Parameters | 358 |
| Group objects | 261 |
Group objects (261)
| No | Name | Function | Size | DPT | Flags |
|---|---|---|---|---|---|
| 0 | Handbedienung | Sperren | 1 Bit | CW | |
| 0 | Object 1 | 1 Bit | CW | ||
| 1 | Handbedienung | Status | 1 Bit | CT | |
| 1 | Object 2 | 1 Bit | CT | ||
| 2 | Object 3 | 1 Bit | CW | ||
| 3 | Sicherheit | Windalarm 1 | 1 Bit | CW | |
| 3 | Object 4 | 1 Bit | CW | ||
| 4 | Sicherheit | Windalarm 2 | 1 Bit | CW | |
| 4 | Object 5 | 1 Bit | CW | ||
| 5 | Sicherheit | Windalarm 3 | 1 Bit | CW | |
| 5 | Object 6 | 1 Bit | CW | ||
| 6 | Sicherheit | Regenalarm | 1 Bit | CW | |
| 6 | Object 7 | 1 Bit | CW | ||
| 7 | Sicherheit | Frostalarm | 1 Bit | CW | |
| 7 | Object 8 | 1 Bit | CW | ||
| 8 | Object 9 | 1 Bit | CW | ||
| 9 | Object 10 | 4 Bytes | CT | ||
| 10 | Object 11 | 1 Bit | CW | ||
| 10 | Ausgang 1 | Langzeitbetrieb | 1 Bit | CW | |
| 11 | Object 12 | 1 Bit | CW | ||
| 11 | Ausgang 1 | Kurzzeitbetrieb | 1 Bit | CW | |
| 12 | Object 13 | 1 Bit | CW | ||
| 13 | Object 14 | 1 Byte | CW | ||
| 14 | Object 15 | 1 Bit | CT | ||
| 15 | Object 16 | 1 Bit | CW | ||
| 16 | Object 17 | 1 Bit | CW | ||
| 17 | Object 18 | 1 Bit | CW | ||
| 18 | Object 19 | 1 Bit | CW | ||
| 19 | Object 20 | 2 Bytes | CW | ||
| 20 | Object 21 | 1 Bit | CW | ||
| 21 | Object 22 | 2 Bytes | CT | ||
| 22 | Object 23 | 1 Bit | CT | ||
| 23 | Object 24 | 1 Bit | CW | ||
| 24 | Object 25 | 1 Byte | CT | ||
| 24 | Ausgang 1 | Rückmeldung Rollladenposition | 1 Byte | CR | |
| 24 | Ausgang 1 | Rückmeldung Rollladenposition | 1 Byte | CT | |
| 25 | Object 26 | 1 Byte | CT | ||
| 26 | Object 27 | 1 Bit | CR | ||
| 26 | Ausgang 1 | Rückmeldung ungültige Position | 1 Bit | CR | |
| 26 | Ausgang 1 | Rückmeldung ungültige Position | 1 Bit | CT | |
| 27 | Object 28 | 1 Bit | CT | ||
| 27 | Ausgang 1 | Rückmeldung Antriebsbewegung | 1 Bit | CR | |
| 27 | Ausgang 1 | Rückmeldung Antriebsbewegung | 1 Bit | CT | |
| 28 | Object 29 | 1 Byte | CW | ||
| 28 | Ausgang 1 | Position Rolllade/Markise | 1 Byte | CW | |
| 29 | Object 30 | 1 Byte | CW | ||
| 30 | Object 31 | 1 Bit | CT | ||
| 31 | Object 32 | 1 Bit | CT | ||
| 32 | Object 33 | 2 Bytes | CW | ||
| 33 | Object 34 | 1 Bit | CW | ||
| 34 | Object 35 | 2 Bytes | CT | ||
| 35 | Object 36 | 1 Bit | CT | ||
| 36 | Object 37 | 1 Bit | CW | ||
| 36 | Ausgang 2 | Langzeitbetrieb | 1 Bit | CW | |
| 37 | Object 38 | 1 Bit | CW | ||
| 37 | Ausgang 2 | Kurzzeitbetrieb | 1 Bit | CW | |
| 38 | Object 39 | 1 Bit | CW | ||
| 39 | Object 40 | 1 Bit | CW | ||
| 40 | Object 41 | 1 Bit | CW | ||
| 41 | Object 42 | 1 Byte | CW | ||
| 42 | Object 43 | 1 Byte | CW | ||
| 43 | Object 44 | 1 Byte | CT | ||
| 44 | Object 45 | 1 Bit | CT | ||
| 45 | Object 46 | 2 Bytes | CW | ||
| 46 | Object 47 | 1 Bit | CW | ||
| 47 | Object 48 | 2 Bytes | CT | ||
| 48 | Object 49 | 1 Bit | CT | ||
| 49 | Object 50 | 1 Bit | CW | ||
| 50 | Object 51 | 1 Bit | CW | ||
| 50 | Ausgang 2 | Rückmeldung Rollladenposition | 1 Byte | CR | |
| 50 | Ausgang 2 | Rückmeldung Rollladenposition | 1 Byte | CT | |
| 51 | Object 52 | 1 Bit | CW | ||
| 52 | Object 53 | 1 Bit | CW | ||
| 52 | Ausgang 2 | Rückmeldung ungültige Position | 1 Bit | CR | |
| 52 | Ausgang 2 | Rückmeldung ungültige Position | 1 Bit | CT | |
| 53 | Object 54 | 1 Bit | CW | ||
| 53 | Ausgang 2 | Rückmeldung Antriebsbewegung | 1 Bit | CR | |
| 53 | Ausgang 2 | Rückmeldung Antriebsbewegung | 1 Bit | CT | |
| 54 | Object 55 | 1 Byte | CW | ||
| 54 | Ausgang 2 | Position Rolllade/Markise | 1 Byte | CW | |
| 55 | Object 56 | 1 Byte | CW | ||
| 56 | Object 57 | 1 Byte | CT | ||
| 57 | Object 58 | 1 Bit | CT | ||
| 58 | Object 59 | 2 Bytes | CW | ||
| 59 | Object 60 | 1 Bit | CW | ||
| 60 | Object 61 | 2 Bytes | CT | ||
| 61 | Object 62 | 1 Bit | CT | ||
| 62 | Object 63 | 1 Bit | CW | ||
| 62 | Ausgang 3 | Langzeitbetrieb | 1 Bit | CW | |
| 63 | Object 64 | 1 Bit | CW | ||
| 63 | Ausgang 3 | Kurzzeitbetrieb | 1 Bit | CW | |
| 64 | Object 65 | 1 Bit | CW | ||
| 65 | Object 66 | 1 Bit | CW | ||
| 66 | Object 67 | 1 Bit | CW | ||
| 67 | Object 68 | 1 Byte | CW | ||
| 68 | Object 69 | 1 Byte | CW | ||
| 69 | Object 70 | 1 Byte | CT | ||
| 70 | Object 71 | 1 Bit | CT | ||
| 71 | Object 72 | 2 Bytes | CW | ||
| 72 | Object 73 | 1 Bit | CW | ||
| 73 | Object 74 | 2 Bytes | CT | ||
| 74 | Object 75 | 1 Bit | CT | ||
| 75 | Object 76 | 1 Bit | CW | ||
| 76 | Object 77 | 1 Bit | CW | ||
| 76 | Ausgang 3 | Rückmeldung Rollladenposition | 1 Byte | CR | |
| 76 | Ausgang 3 | Rückmeldung Rollladenposition | 1 Byte | CT | |
| 77 | Object 78 | 1 Bit | CW | ||
| 78 | Object 79 | 1 Bit | CW | ||
| 78 | Ausgang 3 | Rückmeldung ungültige Position | 1 Bit | CR | |
| 78 | Ausgang 3 | Rückmeldung ungültige Position | 1 Bit | CT | |
| 79 | Object 80 | 1 Bit | CW | ||
| 79 | Ausgang 3 | Rückmeldung Antriebsbewegung | 1 Bit | CR | |
| 79 | Ausgang 3 | Rückmeldung Antriebsbewegung | 1 Bit | CT | |
| 80 | Object 81 | 1 Byte | CW | ||
| 80 | Ausgang 3 | Position Rolllade/Markise | 1 Byte | CW | |
| 81 | Object 82 | 1 Byte | CW | ||
| 82 | Object 83 | 1 Byte | CT | ||
| 83 | Object 84 | 1 Bit | CT | ||
| 84 | Object 85 | 2 Bytes | CW | ||
| 85 | Object 86 | 1 Bit | CW | ||
| 86 | Object 87 | 2 Bytes | CT | ||
| 87 | Object 88 | 1 Bit | CT | ||
| 88 | Object 89 | 1 Bit | CW | ||
| 88 | Ausgang 4 | Langzeitbetrieb | 1 Bit | CW | |
| 89 | Object 90 | 1 Bit | CW | ||
| 89 | Ausgang 4 | Kurzzeitbetrieb | 1 Bit | CW | |
| 90 | Object 91 | 1 Bit | CW | ||
| 91 | Object 92 | 1 Bit | CW | ||
| 92 | Object 93 | 1 Bit | CW | ||
| 93 | Object 94 | 1 Byte | CW | ||
| 94 | Object 95 | 1 Byte | CW | ||
| 95 | Object 96 | 1 Byte | CT | ||
| 96 | Object 97 | 1 Bit | CT | ||
| 97 | Object 98 | 2 Bytes | CW | ||
| 98 | Object 99 | 1 Bit | CW | ||
| 99 | Object 100 | 2 Bytes | CT | ||
| 100 | Object 101 | 1 Bit | CT | ||
| 101 | Object 102 | 1 Bit | CW | ||
| 102 | Object 103 | 1 Bit | CW | ||
| 102 | Ausgang 4 | Rückmeldung Rollladenposition | 1 Byte | CT | |
| 102 | Ausgang 4 | Rückmeldung Rollladenposition | 1 Byte | CR | |
| 103 | Object 104 | 1 Bit | CW | ||
| 104 | Object 105 | 1 Bit | CW | ||
| 104 | Ausgang 4 | Rückmeldung ungültige Position | 1 Bit | CT | |
| 104 | Ausgang 4 | Rückmeldung ungültige Position | 1 Bit | CR | |
| 105 | Object 106 | 1 Bit | CW | ||
| 105 | Ausgang 4 | Rückmeldung Antriebsbewegung | 1 Bit | CT | |
| 105 | Ausgang 4 | Rückmeldung Antriebsbewegung | 1 Bit | CR | |
| 106 | Object 107 | 1 Byte | CW | ||
| 106 | Ausgang 4 | Position Rolllade/Markise | 1 Byte | CW | |
| 107 | Object 108 | 1 Byte | CW | ||
| 108 | Object 109 | 1 Byte | CT | ||
| 109 | Object 110 | 1 Bit | CT | ||
| 110 | Object 111 | 2 Bytes | CW | ||
| 111 | Object 112 | 1 Bit | CW | ||
| 112 | Object 113 | 2 Bytes | CT | ||
| 113 | Object 114 | 1 Bit | CT | ||
| 114 | Object 115 | 1 Bit | CW | ||
| 115 | Object 116 | 1 Bit | CW | ||
| 116 | Object 117 | 1 Bit | CW | ||
| 117 | Object 118 | 1 Bit | CW | ||
| 118 | Object 119 | 1 Bit | CW | ||
| 119 | Object 120 | 1 Byte | CW | ||
| 120 | Object 121 | 1 Byte | CW | ||
| 121 | Object 122 | 1 Byte | CT | ||
| 122 | Object 123 | 1 Bit | CT | ||
| 123 | Object 124 | 2 Bytes | CW | ||
| 124 | Object 125 | 1 Bit | CW | ||
| 125 | Object 126 | 2 Bytes | CT | ||
| 126 | Object 127 | 1 Bit | CT | ||
| 127 | Object 128 | 1 Bit | CW | ||
| 128 | Object 129 | 1 Bit | CW | ||
| 129 | Object 130 | 1 Bit | CW | ||
| 130 | Object 131 | 1 Bit | CW | ||
| 131 | Object 132 | 1 Bit | CW | ||
| 132 | Object 133 | 1 Byte | CW | ||
| 133 | Object 134 | 1 Byte | CW | ||
| 134 | Object 135 | 1 Byte | CT | ||
| 135 | Object 136 | 1 Bit | CT | ||
| 136 | Object 137 | 2 Bytes | CW | ||
| 137 | Object 138 | 1 Bit | CW | ||
| 138 | Object 139 | 2 Bytes | CT | ||
| 139 | Object 140 | 1 Bit | CT | ||
| 140 | Object 141 | 1 Bit | CW | ||
| 141 | Object 142 | 1 Bit | CW | ||
| 142 | Object 143 | 1 Bit | CW | ||
| 143 | Object 144 | 1 Bit | CW | ||
| 144 | Object 145 | 1 Bit | CW | ||
| 145 | Object 146 | 1 Byte | CW | ||
| 146 | Object 147 | 1 Byte | CW | ||
| 147 | Object 148 | 1 Byte | CT | ||
| 148 | Object 149 | 1 Bit | CT | ||
| 149 | Object 150 | 2 Bytes | CW | ||
| 150 | Object 151 | 1 Bit | CW | ||
| 151 | Object 152 | 2 Bytes | CT | ||
| 152 | Object 153 | 1 Bit | CT | ||
| 153 | Object 154 | 1 Bit | CW | ||
| 154 | Object 155 | 1 Bit | CW | ||
| 155 | Object 156 | 1 Bit | CW | ||
| 156 | Object 157 | 1 Bit | CW | ||
| 157 | Object 158 | 1 Bit | CW | ||
| 158 | Object 159 | 1 Byte | CW | ||
| 159 | Object 160 | 1 Byte | CW | ||
| 160 | Object 161 | 1 Byte | CT | ||
| 161 | Object 162 | 1 Bit | CT | ||
| 162 | Object 163 | 2 Bytes | CW | ||
| 163 | Object 164 | 1 Bit | CW | ||
| 164 | Object 165 | 2 Bytes | CT | ||
| 165 | Object 166 | 1 Bit | CT | ||
| 166 | Object 167 | 1 Bit | CW | ||
| 167 | Object 168 | 1 Bit | CW | ||
| 168 | Object 169 | 1 Bit | CW | ||
| 169 | Object 170 | 1 Bit | CW | ||
| 170 | Object 171 | 1 Bit | CW | ||
| 171 | Object 172 | 1 Byte | CW | ||
| 172 | Object 173 | 1 Byte | CW | ||
| 173 | Object 174 | 1 Byte | CT | ||
| 174 | Object 175 | 1 Bit | CT | ||
| 175 | Object 176 | 2 Bytes | CW | ||
| 176 | Object 177 | 1 Bit | CW | ||
| 177 | Object 178 | 2 Bytes | CT | ||
| 178 | Object 179 | 1 Bit | CT | ||
| 179 | Object 180 | 1 Bit | CW | ||
| 180 | Object 181 | 1 Bit | CW | ||
| 181 | Object 182 | 1 Bit | CW | ||
| 182 | Object 183 | 1 Bit | CW | ||
| 183 | Object 184 | 1 Bit | CW | ||
| 184 | Object 185 | 1 Byte | CW | ||
| 185 | Object 186 | 1 Byte | CW | ||
| 186 | Object 187 | 1 Byte | CT | ||
| 187 | Object 188 | 1 Bit | CT | ||
| 188 | Object 189 | 2 Bytes | CW | ||
| 189 | Object 190 | 1 Bit | CW | ||
| 190 | Object 191 | 2 Bytes | CT | ||
| 191 | Object 192 | 1 Bit | CT | ||
| 192 | Object 193 | 1 Bit | CW | ||
| 193 | Object 194 | 1 Bit | CW | ||
| 194 | Object 195 | 1 Bit | CW | ||
| 195 | Object 196 | 1 Bit | CW | ||
| 196 | Object 197 | 1 Bit | CW | ||
| 197 | Object 198 | 1 Byte | CW | ||
| 198 | Object 199 | 1 Byte | CW | ||
| 199 | Object 200 | 1 Byte | CT | ||
| 200 | Object 201 | 1 Bit | CT | ||
| 201 | Object 202 | 2 Bytes | CW | ||
| 202 | Object 203 | 1 Bit | CW | ||
| 203 | Object 204 | 2 Bytes | CT | ||
| 204 | Object 205 | 1 Bit | CT | ||
| 205 | Object 206 | 1 Bit | CW | ||
| 206 | Object 207 | 1 Bit | CW | ||
| 207 | Object 208 | 1 Bit | CW | ||
| 208 | Object 209 | 1 Bit | CW | ||
| 209 | Object 210 | 1 Bit | CW | ||
| 210 | Object 211 | 1 Byte | CW | ||
| 211 | Object 212 | 1 Byte | CW | ||
| 212 | Object 213 | 1 Byte | CT | ||
| 213 | Object 214 | 1 Bit | CT | ||
| 214 | Object 215 | 2 Bytes | CW | ||
| 215 | Object 216 | 1 Bit | CW | ||
| 216 | Object 217 | 2 Bytes | CT | ||
| 217 | Object 218 | 1 Bit | CT |
Parameters (118)
| Parameter | Type | Default |
|---|---|---|
| Objekte | list | freigegeben |
| Müll | list | gesperrt |
| Hardware | list | 000A0000004D |
| Müll | list | Aus |
| ETS_Download_I | unsignedInt 0…255 | 1 |
| ETS_Download_II | unsignedInt 0…255 | 1 |
| Maximal zulässige Fahrzeitänderung | list | 25 % |
| Kanaldefinition | list | vierkanalig (4 x 230 V AC) |
| Definition_Relaistyp_A2 | list | vierkanalig (4 x 230 V AC) |
| Definition_Relaistyp_A3 | list | vierkanalig (4 x 230 V AC) |
| Definition_Relaistyp_JA_A4 | list | vierkanalig (4 x 230 V AC) |
| Verzögerung nach Busspannungswiederkehr Tage (0...7) | unsignedInt 0…7 | 0 |
| Verzögerung nach Busspannungswiederkehr Stunden (0...23) | unsignedInt 0…23 | 0 |
| Verzögerung nach Busspannungswiederkehr Minuten (0...59) | unsignedInt 0…59 | 0 |
| Sekunden (0...59) | unsignedInt 0…59 | 17 |
| Millisekunden (0...99) | unsignedInt 0…99 | 0 |
| Zentralfunktion für Schaltausgänge ? | list | Nein |
| Zentralfunktion ? | list | Nein |
| Sammelrückmeldung für Schaltausgänge nutzen ? | list | Nein |
| Zeit für Blinken (alle zugeordneten Schaltausgänge) | list | 1 s |
| Zeit für zyklische Überwachung Tage (0...7) | unsignedInt 0…7 | 0 |
| Zeit für zyklische Überwachung Stunden (0...23) | unsignedInt 0…23 | 0 |
| Minuten (0...59) | unsignedInt 0…59 | 2 |
| Sekunden (10...59) | unsignedInt 10…59 | 10 |
| Zeit für zykl. Senden der Rückmeldung Tage (0...7) | unsignedInt 0…7 | 0 |
| Zeit für zykl. Senden der Rückmeldung Stunden (0...23) | unsignedInt 0…23 | 0 |
| Zeit für zykl. Senden Betriebsstunden Tage (0...7) | unsignedInt 0…7 | 1 |
| Stunden (0...23) | unsignedInt 0…23 | 0 |
| Minuten (0...59) | unsignedInt 0…59 | 0 |
| Freigabe_Ja | list | Ja |
| Freigabe_Nein | list | Nein |
| Sicherheitsfunktionen | list | gesperrt |
| Windalarm 1 | list | gesperrt |
| Windalarm 2 | list | gesperrt |
| Windalarm 3 | list | gesperrt |
| Regenalarm | list | gesperrt |
| Frostalarm | list | gesperrt |
| Priorität der Sicherheits-Alarme (hoch --> mittel --> niedrig) | list | Wind --> Regen --> Frost |
| Überwachung für Windalarme verwenden ? (Nur bei freigegebenen Windalarmen!) | list | Nein |
| Zeit für Überwachung Windalarm Tage (0...7) | unsignedInt 0…7 | 7 |
| Zeit für Überwachung Windalarm Stunden (0...23) | unsignedInt 0…23 | 23 |
| Minuten (1...59) | unsignedInt 1…59 | 59 |
| Sekunden (0...59) | unsignedInt 0…59 | 59 |
| Millisekunden (0...99) | unsignedInt 0…99 | 99 |
| Überwachung für Regenalarm verwenden ? | list | Nein |
| Zeit für Überwachung Regenalarm Tage (0...7) | unsignedInt 0…7 | 7 |
| Zeit für Überwachung Regenalarm Stunden (0...23) | unsignedInt 0…23 | 23 |
| Überwachung für Frostalarm verwenden ? | list | Nein |
| Zeit für Überwachung Frostalarm Tage (0...7) | unsignedInt 0…7 | 7 |
| Zeit für Überwachung Frostalarm Stunden (0...23) | unsignedInt 0…23 | 23 |
| Handbedienung bei Busspannungsausfall | list | freigegeben |
| Handbedienung bei Busbetrieb | list | freigegeben |
| Sperrfunktion ? | list | Nein |
| Polarität des Sperrobjektes | list | 0 = freigegeben; 1 = gesperrt |
| Status senden ? | list | Nein |
| Funktion und Polarität Statusobjekt | list | 0 = inaktiv; 1 = Handb. aktiv |
| Verhalten am Ende der permanenten Handbedienung bei Busbetrieb | list | keine Änderung |
| Bussteuerung von einzelnen Ausgängen bei Busbetrieb sperrbar ? | list | Nein |
| Ausgang 1 | list | 1 x Jalousieausgang |
| Ausgang 2 | list | 1 x Jalousieausgang |
| Ausgang 3 | list | 1 x Jalousieausgang |
| Ausgang 4 | list | 1 x Jalousieausgang |
| Ausgang 5 | list | 1 x Jalousieausgang |
| Ausgang 6 | list | 1 x Jalousieausgang |
| Ausgang 7 | list | 1 x Jalousieausgang |
| Ausgang 8 | list | 1 x Jalousieausgang |
| Betriebsart (Bitte zuerst einstellen!) | list | Rolllade / Markise |
| Verhalten nach ETS-Programmiervorgang | list | stopp |
| Verhalten bei Busspannungsausfall | list | keine Reaktion |
| Position Rolllade / Markise bei Busspannungsausfall 0...100%) | unsignedInt 0…100 | 0 |
| Verhalten nach Bus- oder Netzspannungswiederkehr | list | stopp |
| Position Rolllade / Markise bei Bus-/Netzspgs.wiederkehr (0...100%) | unsignedInt 0…100 | 0 |
| Fahrzeitverlängerung für Aufwärtsfahrt | list | 2 % |
| Automatische Endlagenerkennung ? | list | Nein |
| Kurzzeitbetrieb | list | Ja |
| Kurzzeitbetrieb Tage (0...7) | unsignedInt 0…7 | 0 |
| Kurzzeitbetrieb Stunden (0...23) | unsignedInt 0…23 | 0 |
| Kurzzeitbetrieb Minuten (0...59) | unsignedInt 0…59 | 0 |
| Zeit für Kurzzeitbetrieb Sekunden (0...59) | unsignedInt 0…59 | 0 |
| Millisekunden (0...99 x 10) | unsignedInt 0…99 | 50 |
| Langzeitbetrieb | list | wie Fahrzeit Rolllade/Markise + 20 % |
| Fahrzeit Behang Tage (0...7) | unsignedInt 0…7 | 0 |
| Fahrzeit Behang Stunden (0...23) | unsignedInt 0…23 | 0 |
| Fahrzeit Rolllade / Markise Minuten (0...19) | unsignedInt 0…19 | 1 |
| Sekunden (0...59) | unsignedInt 0…59 | 0 |
| Fahrzeit Behang Millisekunden (0...99) | unsignedInt 0…99 | 0 |
| Fahrzeit Lamellen Tage (0...7) | unsignedInt 0…7 | 0 |
| Fahrzeit Lamellen Stunden (0...23) | unsignedInt 0…23 | 0 |
| Umschaltzeit bei Fahrtrichtungswechsel Tage | unsignedInt 0…7 | 0 |
| Umschaltzeit bei Fahrtrichtungswechsel | list | 1 s |
| Umschaltzeit bei Fahrtrichtungswechsel Stunden | unsignedInt 0…23 | 0 |
| Umschaltzeit bei Fahrtrichtungswechsel Minuten | unsignedInt 0…59 | 0 |
| Umschaltzeit bei Fahrtrichtungswechsel Sekunden (0...59) | unsignedInt 0…59 | 1 |
| Millisekunden (0...9 x 100) | unsignedInt 0…9 | 0 |
| Rückmeldungs-Funktionen | list | gesperrt |
| Sicherheits-Funktionen | list | gesperrt |
| Sonnenschutz-Funktionen | list | gesperrt |
| Szenenfunktion | list | gesperrt |
| Zwangsstellungs-Funktion | list | gesperrt |
| Funktion Tuchstraffung | list | gesperrt |
| Zuordnung zur Zentralfunktion ? | list | Nein |
| Rückmeldung Rollladen-/Markisenposition | list | Rückmeldeobjekt ist aktives Meldeobjekt |
| Zeitverzögerung für Rückmeldung nach Busspannungswiederkehr ? | list | Nein |
| Rückmeldung ungültige Rollladen- / Markisenposition | list | keine Rückmeldung |
| Rückmeldung Antriebsbewegung | list | keine Rückmeldung |
| Zuordnung zu Windalarmen | list | Nein |
| Verhalten bei Windalarm | list | keine Reaktion |
| Zuordnung zum Regenalarm | list | Nein |
| Verhalten bei Regenalarm | list | keine Reaktion |
| Zuordnung zum Frostalarm | list | Nein |
| Verhalten bei Frostalarm | list | keine Reaktion |
| Verhalten am Ende der Sicherheit (Wind, Regen, Frost) | list | keine Reaktion |
| Art des Sonnenschutzes | list | einfacher Sonnenschutz |
| Priorität von Sonnenschutz-Betrieb zu direktem Betrieb | list | gleiche Priorität |
| Polarität Objekt "Sonne / Beschattung Fassade" | list | Sonnenschein = 1; kein Sonnenschein = 0 |
| Position Rolllade / Markise bei Busspannungsausfall (0...100%) | unsignedInt 0…100 | 0 |
| Umschaltzeit bei Fahrtrichtungswechsel Sekunden (0...59) | unsignedInt 0…59 | 0 |
| Millisekunden (0...9 x 100) | unsignedInt 0…9 | 5 |
Version history
| Application | App no | Fingerprint | First seen | Size | File |
|---|---|---|---|---|---|
| Rolllade 20CD11 1.1 latest | $20CD | BE53 | 2026-11-25 | 99 KB | Download |
About this file
This is the official ETS product database for the Berker Rollladenaktor 4fach REG (75314022), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.
More from Berker
- Jalousieaktor 4fach 6A 24V DC Hand REG 75314011
- Jalousieaktor 4/2fach 230 V AC / 12-48 VDC REG 75314018
- 4-fold shutter actuator 6A 230V AC 75314023
- 4-fold blind/shutter actuator 6A 24V DC 75314111
- 4-fold shutter actuator 6A 24V DC 75314118
- 4-fold blind/shutter actuator 6A 230V AC 75314119
- Jalousieaktor 8/4fach 230 V AC / 12-48 V DC REG 75318008
- 8-fold shutter actuator 6A 230V AC 75318107
- 8-fold blind actuator 6A 230V AC 75318108
- 12-fold blind/shutter actuator 6A 230V AC 75319010
- Jalousieaktor 1fach 3A UP 75341004
- Fensterschnittstelle 1/1fach UP 75341006