Jalousieaktor 4/2fach 230 V AC / 12-48 VDC REG 75314018
Berker · Order number 75314018 · Blinds/shutters › Blinds/shutters
75314018
Download .knxprod Jalousie 20A812 1.2 · 240 KB
Product
| Manufacturer | Berker |
|---|---|
| Product name | Jalousieaktor 4/2fach 230 V AC / 12-48 VDC REG |
| Order number | 75314018 |
| Hardware | REG 2006 Jalousieaktor 4fach 230V / 2fach 24VDC |
| Medium | Twisted Pair |
| Bus current (mA) | 6 |
| Rail mounted | Yes |
| Width (mm) | 72 |
| Registration | Certified |
| Languages | de-DE |
| Catalog entry | M-0006_H-6.20.2F.2F.2075314018-1-O000A_HP-20A8-12-3BD9-O000A_CI-75314018-1 |
| Fingerprint | 3BD9 |
| SHA-256 | 44a9cef2e5897f6590b42300866d71c5de670641faf75ffec36a60bb1b042e27 |
| First seen | 2026-11-25 |
| Markets | 69 markets |
Application program: Jalousie 20A812 1.2
| Application number | $20A8 |
|---|---|
| Version | 1.2 |
| Mask version | MV-0705 (7.5) |
| KNX Data Secure | No |
| Minimum ETS version | 3.0d |
| Parameters | 1899 |
| Group objects | 434 |
Group objects (434)
| No | Name | Function | Size | DPT | Flags |
|---|---|---|---|---|---|
| 0 | Handbedienung | Sperren | 1 Bit | CW | |
| 0 | Object 1 | 1 Bit | CW | ||
| 1 | Handbedienung | Status | 1 Bit | CT | |
| 1 | Object 2 | 1 Bit | CT | ||
| 2 | Object 3 | 1 Bit | CW | ||
| 2 | Alle Jalousieausgänge | Zentral fahren | 1 Bit | CW | |
| 3 | Sicherheit | Windalarm 1 | 1 Bit | CW | |
| 3 | Object 4 | 1 Bit | CW | ||
| 4 | Sicherheit | Windalarm 2 | 1 Bit | CW | |
| 4 | Object 5 | 1 Bit | CW | ||
| 5 | Sicherheit | Windalarm 3 | 1 Bit | CW | |
| 5 | Object 6 | 1 Bit | CW | ||
| 6 | Sicherheit | Regenalarm | 1 Bit | CW | |
| 6 | Object 7 | 1 Bit | CW | ||
| 7 | Sicherheit | Frostalarm | 1 Bit | CW | |
| 7 | Object 8 | 1 Bit | CW | ||
| 8 | Object 9 | 1 Bit | CW | ||
| 8 | Alle Schaltausgänge | Zentral schalten | 1 Bit | CW | |
| 9 | Object 10 | 4 Bytes | CT | ||
| 9 | Alle Schaltausgänge | Sammelrückmeldung | 4 Bytes | CT | |
| 9 | Alle Schaltausgänge | Sammelrückmeldung | 4 Bytes | CR | |
| 10 | Ausgang 1/2 | Langzeitbetrieb | 1 Bit | CW | |
| 10 | Object 11 | 1 Bit | CW | ||
| 10 | Ausgang 1 | Langzeitbetrieb | 1 Bit | CW | |
| 11 | Ausgang 1/2 | Kurzzeitbetrieb | 1 Bit | CW | |
| 11 | Object 12 | 1 Bit | CW | ||
| 11 | Ausgang 1 | Kurzzeitbetrieb | 1 Bit | CW | |
| 12 | Ausgang 1/2 | Zwangsstellung | 2 Bit | CW | |
| 12 | Object 13 | 1 Bit | CW | ||
| 12 | Ausgang 1 | Zwangsstellung | 2 Bit | CW | |
| 13 | Ausgang 1/2 | Szenennebenstelle | 1 Byte | CW | |
| 13 | Object 14 | 1 Byte | CW | ||
| 13 | Ausgang 1 | Szenennebenstelle | 1 Byte | CW | |
| 14 | Ausgang 1/2 | Szenenstatus | 1 Byte | CT | |
| 14 | Ausgang 1/2 | Szenenstatus | 1 Byte | CR | |
| 14 | Object 15 | 1 Bit | CT | ||
| 14 | Ausgang 1 | Szenenstatus | 1 Byte | CT | |
| 14 | Ausgang 1 | Szenenstatus | 1 Byte | CR | |
| 15 | Object 16 | 1 Bit | CW | ||
| 15 | Ausgang 1/2 | Automatik | 1 Bit | CW | |
| 15 | Ausgang 1 | Automatik | 1 Bit | CW | |
| 16 | Object 17 | 1 Bit | CW | ||
| 16 | Ausgang 1/2 | Automatik Sperren | 1 Bit | CW | |
| 16 | Ausgang 1/2 | Automatik | 1 Bit | CW | |
| 16 | Ausgang 1 | Automatik Sperren | 1 Bit | CW | |
| 16 | Ausgang 1 | Automatik | 1 Bit | CW | |
| 17 | Object 18 | 1 Bit | CW | ||
| 17 | Ausgang 1/2 | Direkten Betrieb Sperren | 1 Bit | CW | |
| 17 | Ausgang 1 | Direkten Betrieb Sperren | 1 Bit | CW | |
| 18 | Object 19 | 1 Bit | CW | ||
| 18 | Ausgang 1/2 | Sonne / Beschattung Fassade | 1 Bit | CW | |
| 18 | Ausgang 1 | Sonne / Beschattung Fassade | 1 Bit | CW | |
| 19 | Object 20 | 2 Bytes | CW | ||
| 19 | Ausgang 1/2 | Jalousiepos. Sonne/Beschattung | 1 Byte | CW | |
| 19 | Ausgang 1/2 | Rollladepos. Sonne/Beschattung | 1 Byte | CW | |
| 19 | Ausgang 1/2 | Lüftungspos. Sonne/Beschattung | 1 Byte | CW | |
| 19 | Ausgang 1 | Jalousiepos. Sonne/Beschattung | 1 Byte | CW | |
| 19 | Ausgang 1 | Rollladepos. Sonne/Beschattung | 1 Byte | CW | |
| 19 | Ausgang 1 | Lüftungspos. Sonne/Beschattung | 1 Byte | CW | |
| 20 | Object 21 | 1 Bit | CW | ||
| 20 | Ausgang 1/2 | Lamellenpos. Sonne/Beschattung | 1 Byte | CW | |
| 20 | Ausgang 1 | Lamellenpos. Sonne/Beschattung | 1 Byte | CW | |
| 21 | Object 22 | 2 Bytes | CT | ||
| 21 | Ausgang 1/2 | Offset Lamellenposition Sonne | 1 Byte | CW | |
| 21 | Ausgang 1 | Offset Lamellenposition Sonne | 1 Byte | CW | |
| 22 | Object 23 | 1 Bit | CT | ||
| 22 | Ausgang 1/2 | Heizen/Kühlen Präsenz | 1 Bit | CW | |
| 22 | Ausgang 1 | Heizen/Kühlen Präsenz | 1 Bit | CW | |
| 23 | Object 24 | 1 Bit | CW | ||
| 23 | Ausgang 1/2 | Heizen/Kühlen Umschaltung | 1 Bit | CW | |
| 23 | Ausgang 1 | Heizen/Kühlen Umschaltung | 1 Bit | CW | |
| 24 | Ausgang 1/2 | Rückmeldung Jalousieposition | 1 Byte | CR | |
| 24 | Ausgang 1/2 | Rückmeldung Jalousieposition | 1 Byte | CT | |
| 24 | Object 25 | 1 Byte | CT | ||
| 24 | Ausgang 1/2 | Rückmeldung Rollladenposition | 1 Byte | CR | |
| 24 | Ausgang 1/2 | Rückmeldung Rollladenposition | 1 Byte | CT | |
| 24 | Ausgang 1/2 | Rückmeldung Lüftungsklposition | 1 Byte | CR | |
| 24 | Ausgang 1/2 | Rückmeldung Lüftungsklposition | 1 Byte | CT | |
| 24 | Ausgang 1 | Rückmeldung Lüftungsklposition | 1 Byte | CR | |
| 24 | Ausgang 1 | Rückmeldung Lüftungsklposition | 1 Byte | CT | |
| 24 | Ausgang 1 | Rückmeldung Jalousieposition | 1 Byte | CR | |
| 24 | Ausgang 1 | Rückmeldung Jalousieposition | 1 Byte | CT | |
| 24 | Ausgang 1 | Rückmeldung Rollladenposition | 1 Byte | CR | |
| 24 | Ausgang 1 | Rückmeldung Rollladenposition | 1 Byte | CT | |
| 25 | Ausgang 1/2 | Rückmeldung Lamellenposition | 1 Byte | CR | |
| 25 | Ausgang 1/2 | Rückmeldung Lamellenposition | 1 Byte | CT | |
| 25 | Object 26 | 1 Byte | CT | ||
| 25 | Ausgang 1 | Rückmeldung Lamellenposition | 1 Byte | CR | |
| 25 | Ausgang 1 | Rückmeldung Lamellenposition | 1 Byte | CT | |
| 26 | Ausgang 1/2 | Rückmeldung ungültige Position | 1 Bit | CR | |
| 26 | Ausgang 1/2 | Rückmeldung ungültige Position | 1 Bit | CT | |
| 26 | Object 27 | 1 Bit | CR | ||
| 26 | Ausgang 1 | Rückmeldung ungültige Position | 1 Bit | CR | |
| 26 | Ausgang 1 | Rückmeldung ungültige Position | 1 Bit | CT | |
| 27 | Ausgang 1/2 | Rückmeldung Antriebsbewegung | 1 Bit | CR | |
| 27 | Ausgang 1/2 | Rückmeldung Antriebsbewegung | 1 Bit | CT | |
| 27 | Object 28 | 1 Bit | CT | ||
| 27 | Ausgang 1 | Rückmeldung Antriebsbewegung | 1 Bit | CR | |
| 27 | Ausgang 1 | Rückmeldung Antriebsbewegung | 1 Bit | CT | |
| 28 | Ausgang 1/2 | Position Jalousie | 1 Byte | CW | |
| 28 | Ausgang 1/2 | Position Rolllade/Markise | 1 Byte | CW | |
| 28 | Ausgang 1/2 | Position Lüftungsklappe | 1 Byte | CW | |
| 28 | Object 29 | 1 Byte | CW | ||
| 28 | Ausgang 1 | Position Jalousie | 1 Byte | CW | |
| 28 | Ausgang 1 | Position Rolllade/Markise | 1 Byte | CW | |
| 28 | Ausgang 1 | Position Lüftungsklappe | 1 Byte | CW | |
| 29 | Ausgang 1/2 | Position Lamelle | 1 Byte | CW | |
| 29 | Object 30 | 1 Byte | CW | ||
| 29 | Ausgang 1 | Position Lamelle | 1 Byte | CW | |
| 30 | Object 31 | 1 Bit | CT | ||
| 31 | Object 32 | 1 Bit | CT | ||
| 32 | Object 33 | 2 Bytes | CW | ||
| 33 | Object 34 | 1 Bit | CW | ||
| 34 | Object 35 | 2 Bytes | CT | ||
| 35 | Object 36 | 1 Bit | CT | ||
| 36 | Object 37 | 1 Bit | CW | ||
| 36 | Ausgang 2 | Langzeitbetrieb | 1 Bit | CW | |
| 37 | Object 38 | 1 Bit | CW | ||
| 37 | Ausgang 2 | Kurzzeitbetrieb | 1 Bit | CW | |
| 38 | Object 39 | 1 Bit | CW | ||
| 38 | Ausgang 2 | Zwangsstellung | 2 Bit | CW | |
| 39 | Object 40 | 1 Bit | CW | ||
| 39 | Ausgang 2 | Szenennebenstelle | 1 Byte | CW | |
| 40 | Object 41 | 1 Bit | CW | ||
| 40 | Ausgang 2 | Szenenstatus | 1 Byte | CT | |
| 40 | Ausgang 2 | Szenenstatus | 1 Byte | CR | |
| 41 | Object 42 | 1 Byte | CW | ||
| 41 | Ausgang 2 | Automatik | 1 Bit | CW | |
| 42 | Object 43 | 1 Byte | CW | ||
| 42 | Ausgang 2 | Automatik Sperren | 1 Bit | CW | |
| 42 | Ausgang 2 | Automatik | 1 Bit | CW | |
| 43 | Object 44 | 1 Byte | CT | ||
| 43 | Ausgang 2 | Direkten Betrieb Sperren | 1 Bit | CW | |
| 44 | Object 45 | 1 Bit | CT | ||
| 44 | Ausgang 2 | Sonne / Beschattung Fassade | 1 Bit | CW | |
| 45 | Object 46 | 2 Bytes | CW | ||
| 45 | Ausgang 2 | Jalousiepos. Sonne/Beschattung | 1 Byte | CW | |
| 45 | Ausgang 2 | Rollladepos. Sonne/Beschattung | 1 Byte | CW | |
| 45 | Ausgang 2 | Lüftungspos. Sonne/Beschattung | 1 Byte | CW | |
| 46 | Object 47 | 1 Bit | CW | ||
| 46 | Ausgang 2 | Lamellenpos. Sonne/Beschattung | 1 Byte | CW | |
| 47 | Object 48 | 2 Bytes | CT | ||
| 47 | Ausgang 2 | Offset Lamellenposition Sonne | 1 Byte | CW | |
| 48 | Object 49 | 1 Bit | CT | ||
| 48 | Ausgang 2 | Heizen/Kühlen Präsenz | 1 Bit | CW | |
| 49 | Object 50 | 1 Bit | CW | ||
| 49 | Ausgang 2 | Heizen/Kühlen Umschaltung | 1 Bit | CW | |
| 50 | Object 51 | 1 Bit | CW | ||
| 50 | Ausgang 2 | Rückmeldung Jalousieposition | 1 Byte | CT | |
| 50 | Ausgang 2 | Rückmeldung Jalousieposition | 1 Byte | CR | |
| 50 | Ausgang 2 | Rückmeldung Rollladenposition | 1 Byte | CR | |
| 50 | Ausgang 2 | Rückmeldung Rollladenposition | 1 Byte | CT | |
| 50 | Ausgang 2 | Rückmeldung Lüftungsklposition | 1 Byte | CR | |
| 50 | Ausgang 2 | Rückmeldung Lüftungsklposition | 1 Byte | CT | |
| 51 | Object 52 | 1 Bit | CW | ||
| 51 | Ausgang 2 | Rückmeldung Lamellenposition | 1 Byte | CT | |
| 51 | Ausgang 2 | Rückmeldung Lamellenposition | 1 Byte | CR | |
| 52 | Object 53 | 1 Bit | CW | ||
| 52 | Ausgang 2 | Rückmeldung ungültige Position | 1 Bit | CT | |
| 52 | Ausgang 2 | Rückmeldung ungültige Position | 1 Bit | CR | |
| 53 | Object 54 | 1 Bit | CW | ||
| 53 | Ausgang 2 | Rückmeldung Antriebsbewegung | 1 Bit | CT | |
| 53 | Ausgang 2 | Rückmeldung Antriebsbewegung | 1 Bit | CR | |
| 54 | Object 55 | 1 Byte | CW | ||
| 54 | Ausgang 2 | Position Jalousie | 1 Byte | CW | |
| 54 | Ausgang 2 | Position Rolllade/Markise | 1 Byte | CW | |
| 54 | Ausgang 2 | Position Lüftungsklappe | 1 Byte | CW | |
| 55 | Object 56 | 1 Byte | CW | ||
| 55 | Ausgang 2 | Position Lamelle | 1 Byte | CW | |
| 56 | Object 57 | 1 Byte | CT | ||
| 57 | Object 58 | 1 Bit | CT | ||
| 58 | Object 59 | 2 Bytes | CW | ||
| 59 | Object 60 | 1 Bit | CW | ||
| 60 | Object 61 | 2 Bytes | CT | ||
| 61 | Object 62 | 1 Bit | CT | ||
| 62 | Object 63 | 1 Bit | CW | ||
| 62 | Ausgang 3/4 | Langzeitbetrieb | 1 Bit | CW | |
| 62 | Ausgang 3 | Langzeitbetrieb | 1 Bit | CW | |
| 63 | Object 64 | 1 Bit | CW | ||
| 63 | Ausgang 3/4 | Kurzzeitbetrieb | 1 Bit | CW | |
| 63 | Ausgang 3 | Kurzzeitbetrieb | 1 Bit | CW | |
| 64 | Object 65 | 1 Bit | CW | ||
| 64 | Ausgang 3/4 | Zwangsstellung | 2 Bit | CW | |
| 64 | Ausgang 3 | Zwangsstellung | 2 Bit | CW | |
| 65 | Object 66 | 1 Bit | CW | ||
| 65 | Ausgang 3/4 | Szenennebenstelle | 1 Byte | CW | |
| 65 | Ausgang 3 | Szenennebenstelle | 1 Byte | CW | |
| 66 | Object 67 | 1 Bit | CW | ||
| 66 | Ausgang 3/4 | Szenenstatus | 1 Byte | CT | |
| 66 | Ausgang 3/4 | Szenenstatus | 1 Byte | CR | |
| 66 | Ausgang 3 | Szenenstatus | 1 Byte | CT | |
| 66 | Ausgang 3 | Szenenstatus | 1 Byte | CR | |
| 67 | Object 68 | 1 Byte | CW | ||
| 67 | Ausgang 3/4 | Automatik | 1 Bit | CW | |
| 67 | Ausgang 3 | Automatik | 1 Bit | CW | |
| 68 | Object 69 | 1 Byte | CW | ||
| 68 | Ausgang 3/4 | Automatik Sperren | 1 Bit | CW | |
| 68 | Ausgang 3/4 | Automatik | 1 Bit | CW | |
| 68 | Ausgang 3 | Automatik Sperren | 1 Bit | CW | |
| 68 | Ausgang 3 | Automatik | 1 Bit | CW | |
| 69 | Object 70 | 1 Byte | CT | ||
| 69 | Ausgang 3/4 | Direkten Betrieb Sperren | 1 Bit | CW | |
| 69 | Ausgang 3/4 | Sonne / Beschattung Fassade | 1 Bit | CW | |
| 69 | Ausgang 3 | Direkten Betrieb Sperren | 1 Bit | CW | |
| 69 | Ausgang 3 | Sonne / Beschattung Fassade | 1 Bit | CW | |
| 70 | Object 71 | 1 Bit | CT | ||
| 70 | Ausgang 3/4 | Sonne / Beschattung Fassade | 1 Bit | CW | |
| 70 | Ausgang 3 | Sonne / Beschattung Fassade | 1 Bit | CW | |
| 71 | Object 72 | 2 Bytes | CW | ||
| 71 | Ausgang 3/4 | Rollladepos. Sonne/Beschattung | 1 Byte | CW | |
| 71 | Ausgang 3/4 | Lüftungspos. Sonne/Beschattung | 1 Byte | CW | |
| 71 | Ausgang 3/4 | Jalousiepos. Sonne/Beschattung | 1 Byte | CW | |
| 71 | Ausgang 3 | Jalousiepos. Sonne/Beschattung | 1 Byte | CW | |
| 71 | Ausgang 3 | Rollladepos. Sonne/Beschattung | 1 Byte | CW | |
| 71 | Ausgang 3 | Lüftungspos. Sonne/Beschattung | 1 Byte | CW | |
| 72 | Object 73 | 1 Bit | CW | ||
| 72 | Ausgang 3/4 | Lamellenpos. Sonne/Beschattung | 1 Byte | CW | |
| 72 | Ausgang 3 | Lamellenpos. Sonne/Beschattung | 1 Byte | CW | |
| 73 | Object 74 | 2 Bytes | CT | ||
| 73 | Ausgang 3/4 | Offset Lamellenposition Sonne | 1 Byte | CW | |
| 73 | Ausgang 3 | Offset Lamellenposition Sonne | 1 Byte | CW | |
| 74 | Object 75 | 1 Bit | CT | ||
| 74 | Ausgang 3/4 | Heizen/Kühlen Präsenz | 1 Bit | CW | |
| 74 | Ausgang 3 | Heizen/Kühlen Präsenz | 1 Bit | CW | |
| 75 | Object 76 | 1 Bit | CW | ||
| 75 | Ausgang 3/4 | Heizen/Kühlen Umschaltung | 1 Bit | CW | |
| 75 | Ausgang 3 | Heizen/Kühlen Umschaltung | 1 Bit | CW | |
| 76 | Object 77 | 1 Bit | CW | ||
| 76 | Ausgang 3/4 | Rückmeldung Lüftungsklposition | 1 Byte | CT | |
| 76 | Ausgang 3/4 | Rückmeldung Lüftungsklposition | 1 Byte | CR | |
| 76 | Ausgang 3/4 | Rückmeldung Rollladenposition | 1 Byte | CR | |
| 76 | Ausgang 3/4 | Rückmeldung Rollladenposition | 1 Byte | CT | |
| 76 | Ausgang 3/4 | Rückmeldung Jalousieposition | 1 Byte | CT | |
| 76 | Ausgang 3/4 | Rückmeldung Jalousieposition | 1 Byte | CR | |
| 76 | Ausgang 3 | Rückmeldung Rollladenposition | 1 Byte | CR | |
| 76 | Ausgang 3 | Rückmeldung Rollladenposition | 1 Byte | CT | |
| 76 | Ausgang 3 | Rückmeldung Jalousieposition | 1 Byte | CT | |
| 76 | Ausgang 3 | Rückmeldung Jalousieposition | 1 Byte | CR | |
| 76 | Ausgang 3 | Rückmeldung Lüftungsklposition | 1 Byte | CT | |
| 76 | Ausgang 3 | Rückmeldung Lüftungsklposition | 1 Byte | CR | |
| 77 | Object 78 | 1 Bit | CW | ||
| 77 | Ausgang 3/4 | Rückmeldung Lamellenposition | 1 Byte | CT | |
| 77 | Ausgang 3/4 | Rückmeldung Lamellenposition | 1 Byte | CR | |
| 77 | Ausgang 3 | Rückmeldung Lamellenposition | 1 Byte | CT | |
| 77 | Ausgang 3 | Rückmeldung Lamellenposition | 1 Byte | CR | |
| 78 | Object 79 | 1 Bit | CW | ||
| 78 | Ausgang 3/4 | Rückmeldung ungültige Position | 1 Bit | CT | |
| 78 | Ausgang 3/4 | Rückmeldung ungültige Position | 1 Bit | CR | |
| 78 | Ausgang 3 | Rückmeldung ungültige Position | 1 Bit | CR | |
| 78 | Ausgang 3 | Rückmeldung ungültige Position | 1 Bit | CT | |
| 79 | Object 80 | 1 Bit | CW | ||
| 79 | Ausgang 3/4 | Rückmeldung Antriebsbewegung | 1 Bit | CT | |
| 79 | Ausgang 3/4 | Rückmeldung Antriebsbewegung | 1 Bit | CR | |
| 79 | Ausgang 3 | Rückmeldung Antriebsbewegung | 1 Bit | CR | |
| 79 | Ausgang 3 | Rückmeldung Antriebsbewegung | 1 Bit | CT | |
| 80 | Object 81 | 1 Byte | CW | ||
| 80 | Ausgang 3/4 | Position Jalousie | 1 Byte | CW | |
| 80 | Ausgang 3/4 | Position Lüftungsklappe | 1 Byte | CW | |
| 80 | Ausgang 3/4 | Position Rolllade/Markise | 1 Byte | CW | |
| 80 | Ausgang 3 | Position Jalousie | 1 Byte | CW | |
| 80 | Ausgang 3 | Position Lüftungsklappe | 1 Byte | CW | |
| 80 | Ausgang 3 | Position Rolllade/Markise | 1 Byte | CW | |
| 81 | Object 82 | 1 Byte | CW | ||
| 81 | Ausgang 3/4 | Position Lamelle | 1 Byte | CW | |
| 81 | Ausgang 3 | Position Lamelle | 1 Byte | CW | |
| 82 | Object 83 | 1 Byte | CT | ||
| 83 | Object 84 | 1 Bit | CT | ||
| 84 | Object 85 | 2 Bytes | CW | ||
| 85 | Object 86 | 1 Bit | CW | ||
| 86 | Object 87 | 2 Bytes | CT | ||
| 87 | Object 88 | 1 Bit | CT | ||
| 88 | Object 89 | 1 Bit | CW | ||
| 88 | Ausgang 4 | Langzeitbetrieb | 1 Bit | CW | |
| 89 | Object 90 | 1 Bit | CW | ||
| 89 | Ausgang 4 | Kurzzeitbetrieb | 1 Bit | CW | |
| 90 | Object 91 | 1 Bit | CW | ||
| 90 | Ausgang 4 | Zwangsstellung | 2 Bit | CW | |
| 91 | Object 92 | 1 Bit | CW | ||
| 91 | Ausgang 4 | Szenennebenstelle | 1 Byte | CW | |
| 92 | Object 93 | 1 Bit | CW | ||
| 92 | Ausgang 4 | Szenenstatus | 1 Byte | CT | |
| 92 | Ausgang 4 | Szenenstatus | 1 Byte | CR | |
| 93 | Object 94 | 1 Byte | CW | ||
| 93 | Ausgang 4 | Automatik | 1 Bit | CW | |
| 94 | Object 95 | 1 Byte | CW | ||
| 94 | Ausgang 4 | Automatik Sperren | 1 Bit | CW | |
| 94 | Ausgang 4 | Automatik | 1 Bit | CW | |
| 95 | Object 96 | 1 Byte | CT | ||
| 95 | Ausgang 4 | Direkten Betrieb Sperren | 1 Bit | CW | |
| 96 | Object 97 | 1 Bit | CT | ||
| 96 | Ausgang 4 | Sonne / Beschattung Fassade | 1 Bit | CW | |
| 97 | Object 98 | 2 Bytes | CW | ||
| 97 | Ausgang 4 | Jalousiepos. Sonne/Beschattung | 1 Byte | CW | |
| 97 | Ausgang 4 | Rollladepos. Sonne/Beschattung | 1 Byte | CW | |
| 97 | Ausgang 4 | Lüftungspos. Sonne/Beschattung | 1 Byte | CW | |
| 98 | Object 99 | 1 Bit | CW | ||
| 98 | Ausgang 4 | Lamellenpos. Sonne/Beschattung | 1 Byte | CW | |
| 99 | Object 100 | 2 Bytes | CT | ||
| 99 | Ausgang 4 | Offset Lamellenposition Sonne | 1 Byte | CW | |
| 100 | Object 101 | 1 Bit | CT | ||
| 100 | Ausgang 4 | Heizen/Kühlen Präsenz | 1 Bit | CW | |
| 101 | Object 102 | 1 Bit | CW | ||
| 101 | Ausgang 4 | Heizen/Kühlen Umschaltung | 1 Bit | CW | |
| 102 | Object 103 | 1 Bit | CW | ||
| 102 | Ausgang 4 | Rückmeldung Rollladenposition | 1 Byte | CT | |
| 102 | Ausgang 4 | Rückmeldung Jalousieposition | 1 Byte | CR | |
| 102 | Ausgang 4 | Rückmeldung Jalousieposition | 1 Byte | CT | |
| 102 | Ausgang 4 | Rückmeldung Lüftungsklposition | 1 Byte | CT | |
| 102 | Ausgang 4 | Rückmeldung Lüftungsklposition | 1 Byte | CR | |
| 103 | Object 104 | 1 Bit | CW | ||
| 103 | Ausgang 4 | Rückmeldung Lamellenposition | 1 Byte | CT | |
| 103 | Ausgang 4 | Rückmeldung Lamellenposition | 1 Byte | CR | |
| 104 | Object 105 | 1 Bit | CW | ||
| 104 | Ausgang 4 | Rückmeldung ungültige Position | 1 Bit | CT | |
| 104 | Ausgang 4 | Rückmeldung ungültige Position | 1 Bit | CR | |
| 105 | Object 106 | 1 Bit | CW | ||
| 105 | Ausgang 4 | Rückmeldung Antriebsbewegung | 1 Bit | CT | |
| 105 | Ausgang 4 | Rückmeldung Antriebsbewegung | 1 Bit | CR | |
| 106 | Object 107 | 1 Byte | CW | ||
| 106 | Ausgang 4 | Position Jalousie | 1 Byte | CW | |
| 106 | Ausgang 4 | Position Rolllade/Markise | 1 Byte | CW | |
| 106 | Ausgang 4 | Position Lüftungsklappe | 1 Byte | CW | |
| 107 | Object 108 | 1 Byte | CW | ||
| 107 | Ausgang 4 | Position Lamelle | 1 Byte | CW | |
| 108 | Object 109 | 1 Byte | CT | ||
| 109 | Object 110 | 1 Bit | CT | ||
| 110 | Object 111 | 2 Bytes | CW | ||
| 111 | Object 112 | 1 Bit | CW | ||
| 112 | Object 113 | 2 Bytes | CT | ||
| 113 | Object 114 | 1 Bit | CT | ||
| 114 | Object 115 | 1 Bit | CW | ||
| 115 | Object 116 | 1 Bit | CW | ||
| 116 | Object 117 | 1 Bit | CW | ||
| 117 | Object 118 | 1 Bit | CW | ||
| 118 | Object 119 | 1 Bit | CW | ||
| 119 | Object 120 | 1 Byte | CW | ||
| 120 | Object 121 | 1 Byte | CW | ||
| 121 | Object 122 | 1 Byte | CT | ||
| 122 | Object 123 | 1 Bit | CT | ||
| 123 | Object 124 | 2 Bytes | CW | ||
| 124 | Object 125 | 1 Bit | CW | ||
| 125 | Object 126 | 2 Bytes | CT | ||
| 126 | Object 127 | 1 Bit | CT | ||
| 127 | Object 128 | 1 Bit | CW | ||
| 128 | Object 129 | 1 Bit | CW | ||
| 129 | Object 130 | 1 Bit | CW | ||
| 130 | Object 131 | 1 Bit | CW | ||
| 131 | Object 132 | 1 Bit | CW | ||
| 132 | Object 133 | 1 Byte | CW | ||
| 133 | Object 134 | 1 Byte | CW | ||
| 134 | Object 135 | 1 Byte | CT | ||
| 135 | Object 136 | 1 Bit | CT | ||
| 136 | Object 137 | 2 Bytes | CW | ||
| 137 | Object 138 | 1 Bit | CW | ||
| 138 | Object 139 | 2 Bytes | CT | ||
| 139 | Object 140 | 1 Bit | CT | ||
| 140 | Object 141 | 1 Bit | CW | ||
| 141 | Object 142 | 1 Bit | CW | ||
| 142 | Object 143 | 1 Bit | CW | ||
| 143 | Object 144 | 1 Bit | CW | ||
| 144 | Object 145 | 1 Bit | CW | ||
| 145 | Object 146 | 1 Byte | CW | ||
| 146 | Object 147 | 1 Byte | CW | ||
| 147 | Object 148 | 1 Byte | CT | ||
| 148 | Object 149 | 1 Bit | CT | ||
| 149 | Object 150 | 2 Bytes | CW | ||
| 150 | Object 151 | 1 Bit | CW | ||
| 151 | Object 152 | 2 Bytes | CT | ||
| 152 | Object 153 | 1 Bit | CT | ||
| 153 | Object 154 | 1 Bit | CW | ||
| 154 | Object 155 | 1 Bit | CW | ||
| 155 | Object 156 | 1 Bit | CW | ||
| 156 | Object 157 | 1 Bit | CW | ||
| 157 | Object 158 | 1 Bit | CW | ||
| 158 | Object 159 | 1 Byte | CW | ||
| 159 | Object 160 | 1 Byte | CW | ||
| 160 | Object 161 | 1 Byte | CT | ||
| 161 | Object 162 | 1 Bit | CT | ||
| 162 | Object 163 | 2 Bytes | CW | ||
| 163 | Object 164 | 1 Bit | CW | ||
| 164 | Object 165 | 2 Bytes | CT | ||
| 165 | Object 166 | 1 Bit | CT | ||
| 166 | Object 167 | 1 Bit | CW | ||
| 167 | Object 168 | 1 Bit | CW | ||
| 168 | Object 169 | 1 Bit | CW | ||
| 169 | Object 170 | 1 Bit | CW | ||
| 170 | Object 171 | 1 Bit | CW | ||
| 171 | Object 172 | 1 Byte | CW | ||
| 172 | Object 173 | 1 Byte | CW | ||
| 173 | Object 174 | 1 Byte | CT | ||
| 174 | Object 175 | 1 Bit | CT | ||
| 175 | Object 176 | 2 Bytes | CW | ||
| 176 | Object 177 | 1 Bit | CW | ||
| 177 | Object 178 | 2 Bytes | CT | ||
| 178 | Object 179 | 1 Bit | CT | ||
| 179 | Object 180 | 1 Bit | CW | ||
| 180 | Object 181 | 1 Bit | CW | ||
| 181 | Object 182 | 1 Bit | CW | ||
| 182 | Object 183 | 1 Bit | CW | ||
| 183 | Object 184 | 1 Bit | CW | ||
| 184 | Object 185 | 1 Byte | CW | ||
| 185 | Object 186 | 1 Byte | CW | ||
| 186 | Object 187 | 1 Byte | CT | ||
| 187 | Object 188 | 1 Bit | CT | ||
| 188 | Object 189 | 2 Bytes | CW | ||
| 189 | Object 190 | 1 Bit | CW | ||
| 190 | Object 191 | 2 Bytes | CT | ||
| 191 | Object 192 | 1 Bit | CT | ||
| 192 | Object 193 | 1 Bit | CW | ||
| 193 | Object 194 | 1 Bit | CW | ||
| 194 | Object 195 | 1 Bit | CW | ||
| 195 | Object 196 | 1 Bit | CW | ||
| 196 | Object 197 | 1 Bit | CW | ||
| 197 | Object 198 | 1 Byte | CW | ||
| 198 | Object 199 | 1 Byte | CW | ||
| 199 | Object 200 | 1 Byte | CT | ||
| 200 | Object 201 | 1 Bit | CT | ||
| 201 | Object 202 | 2 Bytes | CW | ||
| 202 | Object 203 | 1 Bit | CW | ||
| 203 | Object 204 | 2 Bytes | CT | ||
| 204 | Object 205 | 1 Bit | CT | ||
| 205 | Object 206 | 1 Bit | CW | ||
| 206 | Object 207 | 1 Bit | CW | ||
| 207 | Object 208 | 1 Bit | CW | ||
| 208 | Object 209 | 1 Bit | CW | ||
| 209 | Object 210 | 1 Bit | CW | ||
| 210 | Object 211 | 1 Byte | CW | ||
| 211 | Object 212 | 1 Byte | CW | ||
| 212 | Object 213 | 1 Byte | CT | ||
| 213 | Object 214 | 1 Bit | CT | ||
| 214 | Object 215 | 2 Bytes | CW | ||
| 215 | Object 216 | 1 Bit | CW | ||
| 216 | Object 217 | 2 Bytes | CT | ||
| 217 | Object 218 | 1 Bit | CT |
Parameters (265)
| Parameter | Type | Default |
|---|---|---|
| Objekte | list | freigegeben |
| Hardware | list | 000A00000005 |
| Müll | list | Aus |
| Müll | list | gesperrt |
| ETS_Download_I | unsignedInt 0…255 | 1 |
| ETS_Download_II | unsignedInt 0…255 | 1 |
| Maximal zulässige Fahrzeitänderung | list | 25 % |
| Kanaldefinition | list | vierkanalig (4 x 230 V AC) |
| Definition_Relaistyp_A2 | list | vierkanalig (4 x 230 V AC) |
| Definition_Relaistyp_A3 | list | vierkanalig (4 x 230 V AC) |
| Definition_Relaistyp_JA_A4 | list | zweikanalig (2 x 24 V DC) |
| Verzögerung nach Busspannungswiederkehr Tage (0...7) | unsignedInt 0…7 | 0 |
| Verzögerung nach Busspannungswiederkehr Stunden (0...23) | unsignedInt 0…23 | 0 |
| Verzögerung nach Busspannungswiederkehr Minuten (0...59) | unsignedInt 0…59 | 0 |
| Sekunden (0...59) | unsignedInt 0…59 | 17 |
| Millisekunden (0...99) | unsignedInt 0…99 | 0 |
| Zentralfunktion für Schaltausgänge ? | list | Nein |
| Polarität Zentralobjekt | list | 0 = ausschalten; 1 = einschalten |
| Zentralfunktion ? | list | Nein |
| Polarität Zentralobjekt | list | 0 = AUF; 1 = AB |
| Sammelrückmeldung für Schaltausgänge nutzen ? | list | Nein |
| Zeitverzögerung für Rückmeldung nach Busspannungswiederkehr ? | list | Ja |
| Zyklisches Senden der Sammelrückmeldung ? | list | Nein (Senden nur bei Änderung) |
| Zeit für Blinken (alle zugeordneten Schaltausgänge) | list | 1 s |
| Zeit für zyklische Überwachung Tage (0...7) | unsignedInt 0…7 | 0 |
| Zeit für zyklische Überwachung Stunden (0...23) | unsignedInt 0…23 | 0 |
| Minuten (0...59) | unsignedInt 0…59 | 2 |
| Sekunden (10...59) | unsignedInt 10…59 | 10 |
| Zeit für zykl. Senden der Rückmeldung Tage (0...7) | unsignedInt 0…7 | 0 |
| Zeit für zykl. Senden der Rückmeldung Stunden (0...23) | unsignedInt 0…23 | 0 |
| Zeit für zykl. Senden Betriebsstunden Tage (0...7) | unsignedInt 0…7 | 1 |
| Stunden (0...23) | unsignedInt 0…23 | 0 |
| Minuten (0...59) | unsignedInt 0…59 | 0 |
| Sicherheitsfunktionen | list | gesperrt |
| Freigabe_Ja | list | Ja |
| Freigabe_Nein | list | Nein |
| Windalarm 1 | list | gesperrt |
| Windalarm 2 | list | gesperrt |
| Windalarm 3 | list | gesperrt |
| Regenalarm | list | gesperrt |
| Frostalarm | list | gesperrt |
| Priorität der Sicherheits-Alarme (hoch --> mittel --> niedrig) | list | Wind --> Regen --> Frost |
| Überwachung für Windalarme verwenden ? (Nur bei freigegebenen Windalarmen!) | list | Nein |
| Zeit für Überwachung Windalarm Tage (0...7) | unsignedInt 0…7 | 7 |
| Zeit für Überwachung Windalarm Stunden (0...23) | unsignedInt 0…23 | 0 |
| Minuten (1...59) | unsignedInt 1…59 | 25 |
| Sekunden (0...59) | unsignedInt 0…59 | 0 |
| Überwachung für Regenalarm verwenden ? | list | Nein |
| Zeit für Überwachung Regenalarm Tage (0...7) | unsignedInt 0…7 | 7 |
| Zeit für Überwachung Regenalarm Stunden (0...23) | unsignedInt 0…23 | 0 |
| Minuten (1...59) | unsignedInt 1…59 | 2 |
| Überwachung für Frostalarm verwenden ? | list | Nein |
| Zeit für Überwachung Frostalarm Tage (0...7) | unsignedInt 0…7 | 7 |
| Zeit für Überwachung Frostalarm Stunden (0...23) | unsignedInt 0…23 | 0 |
| Handbedienung bei Busspannungsausfall | list | freigegeben |
| Handbedienung bei Busbetrieb | list | freigegeben |
| Sperrfunktion ? | list | Nein |
| Polarität des Sperrobjektes | list | 0 = freigegeben; 1 = gesperrt |
| Status senden ? | list | Nein |
| Funktion und Polarität Statusobjekt | list | 0 = inaktiv; 1 = Handb. aktiv |
| Verhalten am Ende der permanenten Handbedienung bei Busbetrieb | list | keine Änderung |
| Bussteuerung von einzelnen Ausgängen bei Busbetrieb sperrbar ? | list | Nein |
| Ausgang 1 | list | 1 x Jalousieausgang |
| Ausgang 2 | list | 1 x Jalousieausgang |
| Ausgang 3 | list | 1 x Jalousieausgang |
| Ausgang 4 | list | 1 x Jalousieausgang |
| Ausgang 5 | list | 1 x Jalousieausgang |
| Ausgang 6 | list | 1 x Jalousieausgang |
| Ausgang 7 | list | 1 x Jalousieausgang |
| Ausgang 8 | list | 1 x Jalousieausgang |
| Betriebsart (Bitte zuerst einstellen!) | list | Jalousie |
| Verhalten nach ETS-Programmiervorgang | list | stopp |
| Verhalten bei Busspannungsausfall | list | keine Reaktion |
| Position Jalousie bei Busspannungsausfall (0...100%) | unsignedInt 0…100 | 0 |
| Position Rolllade / Markise bei Busspannungsausfall (0...100%) | unsignedInt 0…100 | 0 |
| Position Lüftungsklappe bei Busspannungsausfall (0...100%) | unsignedInt 0…100 | 0 |
| Position Rolllade / Markise bei Busspannungsausfall 0...100%) | unsignedInt 0…100 | 0 |
| Position Lamelle bei Busspannungsausfall (0...100%) | unsignedInt 0…100 | 0 |
| Verhalten nach Bus- oder Netzspannungswiederkehr | list | stopp |
| Position Jalousie bei Bus-/Netzspgs.wiederkehr (0...100%) | unsignedInt 0…100 | 0 |
| Position Rolllade / Markise bei Bus-/Netzspgs.wiederkehr (0...100%) | unsignedInt 0…100 | 0 |
| Position Lüftungsklappe bei Bus-/Netzspgs.wiederkehr (0...100%) | unsignedInt 0…100 | 0 |
| Position Lamelle bei Bus-/Netzspgs.wiederkehr (0...100%) | unsignedInt 0…100 | 0 |
| Fahrzeitverlängerung für Aufwärtsfahrt | list | 2 % |
| Automatische Endlagenerkennung ? | list | Nein |
| Kurzzeitbetrieb | list | Ja |
| Kurzzeitbetrieb Tage (0...7) | unsignedInt 0…7 | 0 |
| Kurzzeitbetrieb Stunden (0...23) | unsignedInt 0…23 | 0 |
| Kurzzeitbetrieb Minuten (0...59) | unsignedInt 0…59 | 0 |
| Zeit für Kurzzeitbetrieb Sekunden (0...59) | unsignedInt 0…59 | 0 |
| Millisekunden (0...99 x 10) | unsignedInt 0…99 | 50 |
| Langzeitbetrieb | list | wie Fahrzeit Lüftungsklappe + 20 % |
| Langzeitbetrieb | list | wie Fahrzeit Rolllade/Markise + 20 % |
| Langzeitbetrieb | list | wie Fahrzeit Jalousie + 20 % |
| Fahrzeit Jalousie Minuten (0...59) | unsignedInt 0…59 | 1 |
| Fahrzeit Rolllade / Markise Minuten (0...59) | unsignedInt 0…59 | 1 |
| Fahrzeit Lüftungsklappe Minuten (0...59) | unsignedInt 0…59 | 1 |
| Fahrzeit Jalousie Minuten (0...19) | unsignedInt 0…19 | 1 |
| Fahrzeit Rolllade / Markise Minuten (0...19) | unsignedInt 0…19 | 1 |
| Fahrzeit Lüftungsklappe Minuten (0...19) | unsignedInt 0…19 | 1 |
| Fahrzeit Behang Tage (0...7) | unsignedInt 0…7 | 0 |
| Fahrzeit Behang Stunden (0...23) | unsignedInt 0…23 | 0 |
| Fahrzeit Behang Millisekunden (0...99) | unsignedInt 0…99 | 0 |
| Fahrzeit Lamellen Tage (0...7) | unsignedInt 0…7 | 0 |
| Fahrzeit Lamellen Stunden (0...23) | unsignedInt 0…23 | 0 |
| Fahrzeit Lamellen Minuten (0...19) | unsignedInt 0…19 | 0 |
| Sekunden (0...59) | unsignedInt 0…59 | 4 |
| Millisekunden (0...9 x 100) (Zeit Lamellen < Zeit Jalousie!) | unsignedInt 0…9 | 0 |
| Umschaltzeit bei Fahrtrichtungswechsel Tage | unsignedInt 0…7 | 0 |
| Umschaltzeit bei Fahrtrichtungswechsel | list | 1 s |
| Umschaltzeit bei Fahrtrichtungswechsel Stunden | unsignedInt 0…23 | 0 |
| Umschaltzeit bei Fahrtrichtungswechsel Minuten | unsignedInt 0…59 | 0 |
| Umschaltzeit bei Fahrtrichtungswechsel Sekunden (0...59) | unsignedInt 0…59 | 0 |
| Millisekunden (0...9 x 100) | unsignedInt 0…9 | 5 |
| Rückmeldungs-Funktionen | list | gesperrt |
| Sicherheits-Funktionen | list | gesperrt |
| Sonnenschutz-Funktionen | list | gesperrt |
| Szenenfunktion | list | gesperrt |
| Zwangsstellungs-Funktion | list | gesperrt |
| Funktion Tuchstraffung | list | gesperrt |
| Zuordnung zur Zentralfunktion ? | list | Nein |
| Rückmeldung Lüftungsklappenposition | list | Rückmeldeobjekt ist aktives Meldeobjekt |
| Rückmeldung Jalousieposition | list | Rückmeldeobjekt ist aktives Meldeobjekt |
| Rückmeldung Rollladen-/Markisenposition | list | Rückmeldeobjekt ist aktives Meldeobjekt |
| Zeitverzögerung für Rückmeldung nach Busspannungswiederkehr ? | list | Nein |
| Rückmeldung Lamellenposition | list | Rückmeldeobjekt ist aktives Meldeobjekt |
| Rückmeldung ungültige Jalousieposition | list | keine Rückmeldung |
| Rückmeldung ungültige Rollladen- / Markisenposition | list | keine Rückmeldung |
| Rückmeldung ungültige Lüftungsklappenposition | list | keine Rückmeldung |
| Rückmeldung Antriebsbewegung | list | keine Rückmeldung |
| Zuordnung zu Windalarmen | list | Nein |
| Verhalten bei Windalarm | list | keine Reaktion |
| Zuordnung zum Regenalarm | list | Nein |
| Verhalten bei Regenalarm | list | keine Reaktion |
| Zuordnung zum Frostalarm | list | Nein |
| Verhalten bei Frostalarm | list | keine Reaktion |
| Verhalten am Ende der Sicherheit (Wind, Regen, Frost) | list | keine Reaktion |
| Art des Sonnenschutzes | list | einfacher Sonnenschutz |
| Priorität von Automatik-Betrieb zu direktem Betrieb | list | gleiche Priorität |
| Priorität von Sonnenschutz-Betrieb zu direktem Betrieb | list | gleiche Priorität |
| Polarität Objekt "Sonne / Beschattung Fassade" | list | Sonnenschein = 1; kein Sonnenschein = 0 |
| Aktivierung Automatik-Betrieb über | list | Obj. "Automatik" & sofortige Nachführung |
| Sperrfunktion für Automatik-Betrieb? | list | Nein |
| Automatik | list | über Objekt |
| Polarität Objekt "Automatik Sperren" | list | Automatik: freigegeben = 0; gesperrt = 1 |
| Polarität Objekt "Automatik" | list | Automatik: aktiviert = 1; deaktiviert = 0 |
| Sperrfunktion für direkten Betrieb? | list | Nein |
| Polarität Objekt "Direkten Betrieb Sperren" | list | direkter Betrieb: freigegeben = 0; gesperrt = 1 |
| Reaktion bei Automatik-Betrieb Ende | list | auffahren |
| Reaktion bei Automatik-Betrieb Ende | list | Klappe öffnen |
| Zeitverzögerung Sonne/Beschattung Anfang Tage (0...7) | unsignedInt 0…7 | 0 |
| Zeitverzögerung Sonne/Beschattung Anfang Stunden (0...23) | unsignedInt 0…23 | 0 |
| Zeitverzögerung Sonne/Beschattung Anfang Minuten (0...59) | unsignedInt 0…59 | 0 |
| Sekunden (0...59) | unsignedInt 0…59 | 30 |
| Reaktion bei Sonne/Beschattung Anfang | list | feste Jalousie- und Lamellenposition |
| Reaktion bei Sonne/Beschattung Anfang | list | feste Lüftungsklappenposition |
| Reaktion bei Sonne/Beschattung Anfang | list | feste Rollladen- / Markisenposition |
| Szenennummer (1...8) | unsignedInt 1…8 | 1 |
| Feste Jalousieposition | list | wie parametrierter Wert |
| Feste Lüftungsklappenposition | list | wie parametrierter Wert |
| Feste Rollladen- / Markisenposition | list | wie parametrierter Wert |
| Jalousieposition (0...100 %) | unsignedInt 0…255 | 255 |
| Lüftungsklappen- position (0...100 %) | unsignedInt 0…255 | 255 |
| Rollladen- / Markisenposition (0...100 %) | unsignedInt 0…255 | 255 |
| Lüftungsklappen- position (0...100 %) | unsignedInt 0…100 | 50 |
| Rollladen- / Markisenposition (0...100 %) | unsignedInt 0…100 | 50 |
| Jalousieposition (0...100 %) | unsignedInt 0…100 | 50 |
| Feste Lamellenposition (0...100 %) | unsignedInt 0…100 | 50 |
| Referenzfahrt vor jeder Sonnenschutzpositionierung ? | list | Nein |
| Offset bei fester und variabler Lamellenposition | list | kein Offset |
| Offset-Lamellenposition (-100...100%) | signedInt -100…100 | 0 |
| Offset-Lamellenposition durch Objekt bei Bus-/Netzsp.ausfall speichern ? | list | Ja |
| Zeitverzögerung Sonne/Beschattung Ende Tage (0...7) | unsignedInt 0…7 | 0 |
| Zeitverzögerung Sonne/Beschattung Ende Stunden (0...23) | unsignedInt 0…23 | 0 |
| Zeitverzögerung Sonne/Beschattung Ende Minuten (0...59) | unsignedInt 0…59 | 0 |
| Reaktion bei Sonne/Beschattung Ende | list | Klappe öffnen |
| Reaktion bei Sonne/Beschattung Ende | list | auffahren |
| Reaktion bei Sonne/Beschattung Ende | list | feste Rollladen- / Markisenposition |
| Reaktion bei Sonne/Beschattung Ende | list | feste Jalousie- und Lamellenposition |
| Reaktion bei Sonne/Beschattung Ende | list | feste Lüftungsklappenposition |
| Lüftungsklappen- position (0...100 %) | unsignedInt 0…100 | 0 |
| Rollladen- / Markisenposition (0...100 %) | unsignedInt 0…100 | 0 |
| Jalousieposition (0...100 %) | unsignedInt 0…100 | 0 |
| Feste Lamellenposition (0...100 %) | unsignedInt 0…100 | 0 |
| Heizen/Kühlen-Automatik | list | gesperrt |
| Polarität Objekt "Heizen/Kühlen Umschaltung" | list | Kühlen = 0; Heizen = 1 |
| Polarität Objekt "Heizen/Kühlen Präsenz" | list | keine Präsenz = 0; Präsenz = 1 |
| Zeitverzögerung bei Präsenz Anfang Tage | unsignedInt 0…7 | 0 |
| Zeitverzögerung bei Präsenz Anfang Stunden | unsignedInt 0…23 | 0 |
| Zeitverzögerung bei Präsenz Anfang Minuten (0...59) | unsignedInt 0…59 | 0 |
| Millisekunden | unsignedInt 0…99 | 0 |
| Zeitverzögerung bei Präsenz Ende Tage | unsignedInt 0…7 | 0 |
| Zeitverzögerung bei Präsenz Ende Stunden | unsignedInt 0…23 | 0 |
| Zeitverzögerung bei Präsenz Ende Minuten (0...59) | unsignedInt 0…59 | 0 |
| Reaktion bei Sonne/Beschattung Anfang bei Kühlen | list | keine Reaktion |
| Reaktion bei Sonne/Beschattung Ende bei Kühlen | list | keine Reaktion |
| Reaktion bei Sonne/Beschattung Anfang bei Heizen | list | keine Reaktion |
| Reaktion bei Sonne/Beschattung Ende bei Heizen | list | keine Reaktion |
| Szenenabruf verzögern ? | list | Nein |
| Verzögerungszeit Tage (0...7) | unsignedInt 0…7 | 0 |
| Verzögerungszeit Stunden (0...23) | unsignedInt 0…23 | 0 |
| Verzögerungszeit Minuten (0...59) | unsignedInt 0…59 | 0 |
| Sekunden (0...59) | unsignedInt 0…59 | 10 |
| Verzögerungszeit Millisekunden (0...99) | unsignedInt 0…99 | 0 |
| Szenenstatus (Wird später ausgeblendet!) | list | kein Szenenstatus |
| Im Gerät gespeicherte Werte beim ETS-Download überschreiben ? | list | Ja |
| Szene 1 aktivierbar durch Szenennummer (Szenennummer "0" = Szene deaktiviert) | unsignedInt 0…64 | 1 |
| Position Rolllade/Markise bei Szene 1 (0 ... 100 %) | unsignedInt 0…100 | 0 |
| Position Jalousie bei Szene 1 (0 ... 100 %) | unsignedInt 0…100 | 0 |
| Position Lüftungsklappe bei Szene 1 (0 ... 100 %) | unsignedInt 0…100 | 0 |
| Position Lamelle bei Szene 1 (0 ... 100 %) | unsignedInt 0…100 | 0 |
| Speicherfunktion für Szene 1 | list | Nein |
| Szene 2 aktivierbar durch Szenennummer (Szenennummer "0" = Szene deaktiviert) | unsignedInt 0…64 | 2 |
| Position Rolllade/Markise bei Szene 2 (0 ... 100 %) | unsignedInt 0…100 | 10 |
| Position Jalousie bei Szene 2 (0 ... 100 %) | unsignedInt 0…100 | 10 |
| Position Lüftungsklappe bei Szene 2 (0 ... 100 %) | unsignedInt 0…100 | 10 |
| Position Lamelle bei Szene 2 (0 ... 100 %) | unsignedInt 0…100 | 10 |
| Speicherfunktion für Szene 2 | list | Nein |
| Szene 3 aktivierbar durch Szenennummer (Szenennummer "0" = Szene deaktiviert) | unsignedInt 0…64 | 3 |
| Position Jalousie bei Szene 3 (0 ... 100 %) | unsignedInt 0…100 | 20 |
| Position Rolllade/Markise bei Szene 3 (0 ... 100 %) | unsignedInt 0…100 | 20 |
| Position Lüftungsklappe bei Szene 3 (0 ... 100 %) | unsignedInt 0…100 | 20 |
| Position Lamelle bei Szene 3 (0 ... 100 %) | unsignedInt 0…100 | 20 |
| Speicherfunktion für Szene 3 | list | Nein |
| Szene 4 aktivierbar durch Szenennummer (Szenennummer "0" = Szene deaktiviert) | unsignedInt 0…64 | 4 |
| Position Jalousie bei Szene 4 (0 ... 100 %) | unsignedInt 0…100 | 30 |
| Position Rolllade/Markise bei Szene 4 (0 ... 100 %) | unsignedInt 0…100 | 30 |
| Position Lüftungsklappe bei Szene 4 (0 ... 100 %) | unsignedInt 0…100 | 30 |
| Position Lamelle bei Szene 4 (0 ... 100 %) | unsignedInt 0…100 | 30 |
| Speicherfunktion für Szene 4 | list | Nein |
| Szene 5 aktivierbar durch Szenennummer (Szenennummer "0" = Szene deaktiviert) | unsignedInt 0…64 | 5 |
| Position Jalousie bei Szene 5 (0 ... 100 %) | unsignedInt 0…100 | 40 |
| Position Rolllade/Markise bei Szene 5 (0 ... 100 %) | unsignedInt 0…100 | 40 |
| Position Lüftungsklappe bei Szene 5 (0 ... 100 %) | unsignedInt 0…100 | 40 |
| Position Lamelle bei Szene 5 (0 ... 100 %) | unsignedInt 0…100 | 40 |
| Speicherfunktion für Szene 5 | list | Nein |
| Szene 6 aktivierbar durch Szenennummer (Szenennummer "0" = Szene deaktiviert) | unsignedInt 0…64 | 6 |
| Position Jalousie bei Szene 6 (0 ... 100 %) | unsignedInt 0…100 | 50 |
| Position Rolllade/Markise bei Szene 6 (0 ... 100 %) | unsignedInt 0…100 | 50 |
| Position Lüftungsklappe bei Szene 6 (0 ... 100 %) | unsignedInt 0…100 | 50 |
| Position Lamelle bei Szene 6 (0 ... 100 %) | unsignedInt 0…100 | 50 |
| Speicherfunktion für Szene 6 | list | Nein |
| Szene 7 aktivierbar durch Szenennummer (Szenennummer "0" = Szene deaktiviert) | unsignedInt 0…64 | 7 |
| Position Jalousie bei Szene 7 (0 ... 100 %) | unsignedInt 0…100 | 60 |
| Position Rolllade/Markise bei Szene 7 (0 ... 100 %) | unsignedInt 0…100 | 60 |
| Position Lüftungsklappe bei Szene 7 (0 ... 100 %) | unsignedInt 0…100 | 60 |
| Position Lamelle bei Szene 7 (0 ... 100 %) | unsignedInt 0…100 | 60 |
| Speicherfunktion für Szene 7 | list | Nein |
| Szene 8 aktivierbar durch Szenennummer (Szenennummer "0" = Szene deaktiviert) | unsignedInt 0…64 | 8 |
| Position Jalousie bei Szene 8 (0 ... 100 %) | unsignedInt 0…100 | 70 |
| Position Rolllade/Markise bei Szene 8 (0 ... 100 %) | unsignedInt 0…100 | 70 |
| Position Lüftungsklappe bei Szene 8 (0 ... 100 %) | unsignedInt 0…100 | 70 |
| Position Lamelle bei Szene 8 (0 ... 100 %) | unsignedInt 0…100 | 70 |
| Speicherfunktion für Szene 8 | list | Nein |
| Verhalten am Ende der Zwangsstellung | list | Position nachführen |
| Verhalten nach Busspannungswiederkehr | list | keine Zwangsstellung aktiv |
| Zeit für Tuchstraffung Tage (0...7) | unsignedInt 0…7 | 0 |
| Zeit für Tuchstraffung Stunden (0...23) | unsignedInt 0…23 | 0 |
| Zeit für Tuchstraffung Minuten (0...59) | unsignedInt 0…59 | 0 |
| Zeit für Tuchstraffung Sekunden (0...59) | unsignedInt 0…59 | 1 |
| Millisekunden (0...9 x 100) | unsignedInt 0…9 | 0 |
| Fahrzeit Lüftungsklappe Minuten (0...59) | unsignedInt 0…59 | 59 |
| Fahrzeit Jalousie Minuten (0...59) | unsignedInt 0…59 | 59 |
| Fahrzeit Rolllade / Markise Minuten (0...59) | unsignedInt 0…59 | 59 |
| Sekunden (0...59) | unsignedInt 0…59 | 59 |
Version history
| Application | App no | Fingerprint | First seen | Size | File |
|---|---|---|---|---|---|
| Jalousie 20A812 1.2 latest | $20A8 | 3BD9 | 2026-11-25 | 240 KB | Download |
About this file
This is the official ETS product database for the Berker Jalousieaktor 4/2fach 230 V AC / 12-48 VDC REG (75314018), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.
More from Berker
- Jalousieaktor 4fach 6A 24V DC Hand REG 75314011
- Rollladenaktor 4fach REG 75314022
- 4-fold shutter actuator 6A 230V AC 75314023
- 4-fold blind/shutter actuator 6A 24V DC 75314111
- 4-fold shutter actuator 6A 24V DC 75314118
- 4-fold blind/shutter actuator 6A 230V AC 75314119
- Jalousieaktor 8/4fach 230 V AC / 12-48 V DC REG 75318008
- 8-fold shutter actuator 6A 230V AC 75318107
- 8-fold blind actuator 6A 230V AC 75318108
- 12-fold blind/shutter actuator 6A 230V AC 75319010
- Jalousieaktor 1fach 3A UP 75341004
- Fensterschnittstelle 1/1fach UP 75341006