442KNXMF-VO Room Controller S44 442KNXMF-VO

Ave S.p.A. · Order number 442KNXMF-VO · Thermoregulation devices

442KNXMF-VO Room Controller S44

Download .knxprod Ave. Room Controller S44 0.2 · 371 KB

Product

ManufacturerAve S.p.A.
Product name442KNXMF-VO Room Controller S44
Order number442KNXMF-VO
Hardware44xKNXMFxx
MediumTwisted Pair
Bus current (mA)15
Rail mountedNo
RegistrationCertified · 2021-01-12
Languagesde-DE, fr-FR, it-IT, en-US
Catalog entryM-01A7_H-01A720000000-1_HP-0005-02-5317_CI-442KNXMF.2DVO-1
Fingerprint5317
SHA-256cb8444c7e3d03bc34328b3a85409a21da1aa808c1a3b94265f16c3ada4ba2511
First seen2026-11-25
Markets59 markets

Application program: Ave. Room Controller S44 0.2

Application number$0005
Version0.2
Mask versionMV-07B0 (System B)
KNX Data SecureNo
Minimum ETS version5.0
Parameters1250
Group objects755
Group objects (755)
NoNameFunctionSizeDPTFlags
1LED sxFeedback 11 BitDPT.1CW
2LED sxFeedback 21 BitDPT.1CW
3LED sxFeedback 31 BitDPT.1CW
4LED sxFeedback 41 BitDPT.1CW
5LED sxFeedback 51 BitDPT.1CW
6LED sxFeedback 11 Byte5.4 percentage (0..255%)CW
7LED sxFeedback 21 Byte5.4 percentage (0..255%)CW
8LED sxFeedback 31 Byte5.4 percentage (0..255%)CW
9LED sxFeedback 41 Byte5.4 percentage (0..255%)CW
10LED sxFeedback 51 Byte5.4 percentage (0..255%)CW
11LED sxFeedback 12 BytesDPT.7CW
12LED sxFeedback 22 BytesDPT.7CW
13LED sxFeedback 32 BytesDPT.7CW
14LED sxFeedback 42 BytesDPT.7CW
15LED sxFeedback 52 BytesDPT.7CW
16LED dxFeedback 11 BitDPT.1CW
17LED dxFeedback 21 BitDPT.1CW
18LED dxFeedback 31 BitDPT.1CW
19LED dxFeedback 41 BitDPT.1CW
20LED dxFeedback 51 BitDPT.1CW
21LED dxFeedback 11 Byte5.4 percentage (0..255%)CW
22LED dxFeedback 21 Byte5.4 percentage (0..255%)CW
23LED dxFeedback 31 Byte5.4 percentage (0..255%)CW
24LED dxFeedback 41 Byte5.4 percentage (0..255%)CW
25LED dxFeedback 51 Byte5.4 percentage (0..255%)CW
26LED dxFeedback12 BytesDPT.7CW
27LED dxFeedback 22 BytesDPT.7CW
28LED dxFeedback 32 BytesDPT.7CW
29LED dxFeedback 42 BytesDPT.7CW
30LED dxFeedback 52 BytesDPT.7CW
31AlarmSound 11 Bit1.5 alarmCW
32AlarmSound 21 Bit1.5 alarmCW
33AlarmSound 31 Bit1.5 alarmCW
34AlarmSound 41 Bit1.5 alarmCW
35AlarmSound 51 Bit1.5 alarmCW
36AlarmSound 11 Byte5.4 percentage (0..255%)CW
37AlarmSound 21 Byte5.4 percentage (0..255%)CW
38AlarmSound 31 Byte5.4 percentage (0..255%)CW
39AlarmSound 41 Byte5.4 percentage (0..255%)CW
40AlarmSound 51 Byte5.4 percentage (0..255%)CW
41AlarmSound 12 BytesDPT.7CW
42AlarmSound 22 BytesDPT.7CW
43AlarmSound 32 BytesDPT.7CW
44AlarmSound 42 BytesDPT.7CW
45AlarmSound 52 BytesDPT.7CW
46Keypad lockActivation1 Bit1.3 enableCW
47Keypad lockActivation state1 Bit1.11 stateCRT
48Temperature setpointCurrent setpoint2 Bytes9.1 temperature (°C)CRT
49SeasonCurrent heating/cooling season1 Bit1.100 cooling/heatingCRT
50SeasonHeating/cooling season change1 Bit1.100 cooling/heatingCWU
51HVACCrono1 Byte20.102 HVAC modeCW
52HVACRemote1 Byte20.102 HVAC modeCW
53HVACCurrent1 Byte20.102 HVAC modeCRT
54HVACForced state1 Bit1.11 stateCRT
55Temperature setpoint Remote setpoint2 Bytes9.1 temperature (°C)CW
56Error conditionNumber code error1 ByteCRT
57HeatingSetpoint comfort2 Bytes9.1 temperature (°C)CRWU
58HeatingSetpoint standby2 Bytes9.1 temperature (°C)CRWU
59HeatingSetpoint economy2 Bytes9.1 temperature (°C)CRWU
60HeatingSetpoint protection2 Bytes9.1 temperature (°C)CRWU
61HeatingCommand On/Off1 Bit1.1 switchCRT
62Heating&CoolingCommand On/Off1 Bit1.1 switchCRT
63HeatingPercentage command1 Byte5.1 percentage (0..100%)CRT
64Heating&CoolingPercentage command1 Byte5.1 percentage (0..100%)CRT
65Heating auxiliaryCommand On/Off1 Bit1.1 switchCRT
66Heating&Cooling auxiliaryCommand On/Off1 Bit1.1 switchCRT
67Heating auxiliaryDisable function1 Bit1.3 enableCWU
68HeatingState1 Bit1.11 stateCRT
69CoolingSetpoint comfort2 Bytes9.1 temperature (°C)CRWU
70CoolingSetpoint standby2 Bytes9.1 temperature (°C)CRWU
71CoolingSetpoint economy2 Bytes9.1 temperature (°C)CRWU
72CoolingSetpoint protection2 Bytes9.1 temperature (°C)CRWU
73CoolingCommand On/Off1 Bit1.1 switchCRT
74CoolingPercentage command1 Byte5.1 percentage (0..100%)CRT
75Cooling auxiliaryCommand On/Off1 Bit1.1 switchCRT
76Cooling auxiliaryDisable function1 Bit1.3 enableCWU
77CoolingState1 Bit1.11 stateCRT
78VentilationDisable function1 Bit1.3 enableCW
79VentilationSpeed 11 Bit1.1 switchCRT
80VentilationSpeed 21 Bit1.1 switchCRT
81VentilationSpeed 31 Bit1.1 switchCRT
82VentilationSpeeds counter1 Byte5.10 counter pulses (0..255)CRT
83VentilationPercentage speed1 Byte5.1 percentage (0..100%)CRT
84VentilationManual speed1 Byte5.10 counter pulses (0..255)CWU
85VentilationManual fan insertion1 Bit1.11 stateCRWTU
86HumidificationCommand On/Off1 Bit1.1 switchCRT
87HumidificationFunction disable1 Bit1.3 enableCW
88Humidification Setpoint2 Bytes9.7 humidity (%)CRWTU
89DehumidificationCommand On/Off1 Bit1.1 switchCRT
90DehumidificationFunction disable1 Bit1.3 enableCW
91DehumidificationSetpoint2 Bytes9.7 humidity (%)CRWTU
92DehumidificationWater command1 Bit1.1 switchCRT
93DehumidificationIntegration control1 Bit1.1 switchCRT
94DewpointTemperature value2 Bytes9.1 temperature (°C)CRT
95Perceived temperatureTemperature value2 Bytes9.1 temperature (°C)CRT
96A) Internal temperature probeTemperature value2 Bytes9.1 temperature (°C)CRT
97A) Internal temperature probeThreshold 11 Bit1.1 switchCRT
98A) Internal temperature probeThreshold 21 Bit1.1 switchCRT
99B) Internal humidity probeHumidity value - 1 Byte1 Byte5.1 percentage (0..100%)CRT
100B) Internal humidity probeHumidity value - 2 Byte2 Bytes9.7 humidity (%)CRT
101B) Internal humidity probeThreshold 11 Bit1.1 switchCRT
102B) Internal humidity probeThreshold 21 Bit1.1 switchCRT
103C) Remote temperature probe 1Temperature value2 Bytes9.1 temperature (°C)CWU
104C) Remote temperature probe 2Temperature value2 Bytes9.1 temperature (°C)CWU
105C) Remote temperature probe 3Temperature value2 Bytes9.1 temperature (°C)CWU
106C) Remote temperature probe 4Temperature value2 Bytes9.1 temperature (°C)CWU
107D) Remote humidity probe 1Humidity value - 1 Byte1 Byte5.1 percentage (0..100%)CWU
108D) Remote humidity probe 1Humidity value - 2 Byte2 Bytes9.7 humidity (%)CWU
109D) Remote humidity probe 2Humidity value - 1 Byte1 Byte5.1 percentage (0..100%)CWU
110D) Remote humidity probe 2Humidity value - 2 Byte2 Bytes9.7 humidity (%)CWU
111E) Antistratification temperature probeTemperature value2 Bytes9.1 temperature (°C)CWU
112F) Outdoor tempertaure probeTemperature value2 Bytes9.1 temperature (°C)CWTU
113G) Floor surface temperature probeTemperature value2 Bytes9.1 temperature (°C)CWU
114H) Cooling pump flow temperature probeTemperature value2 Bytes9.1 temperature (°C)CWU
115I) Air quality CO2 probe (ppm)Concentration2 Bytes9.8 parts/million (ppm)CWTU
116L) Zone 2 - TemperatureTemperature value2 Bytes9.1 temperature (°C)CWTU
117L) Zone 2 - TemperatureSeason change1 Bit1.100 cooling/heatingCWU
118L) Zone 2 - TemperatureCurrent season1 Bit1.100 cooling/heatingCRT
119L) Zone 2 - TemperatureValve state1 Bit1.1 switchCWTU
120L) Zone 2 - TemperatureSetpoint2 Bytes9.1 temperature (°C)CRWTU
121L) Zone 2 - TemperatureHVAC input1 Byte20.102 HVAC modeCWTU
122L) Zone 2 - TemperatureHVAC output1 Byte20.102 HVAC modeCRT
123M) Zone 2 - HumidityHumidity value - 1 Byte1 Byte5.1 percentage (0..100%)CWTU
124M) Zone 2 - HumidityHumidity value - 2 Byte2 Bytes9.7 humidity (%)CWTU
125N) Coil battery probeTemperature value2 Bytes9.1 temperature (°C)CWU
126O) Anticondensation contactSwitch state1 Bit1.11 stateCWU
127Anticondensation alarmAlarm state1 Bit1.5 alarmCRT
128P) Window contact 1Contact state1 Bit1.19 window/doorCWU
129P) Window contact 2Contact state1 Bit1.19 window/doorCWU
130P) Window contact 3Contact state1 Bit1.19 window/doorCWU
131P) Window contact 4Contact state1 Bit1.19 window/doorCWU
132Q) Presence sensor contact 1Contact state1 Bit1.18 occupancyCWU
133Q) Presence sensor contact 2Contact state1 Bit1.18 occupancyCWU
134Q) Presence sensor contact 3Contact state1 Bit1.18 occupancyCWU
135Q) Presence sensor contact 4Contact state1 Bit1.18 occupancyCWU
136R) Card holder contactContact state1 Bit1.1 switchCWU
137S1) Room temperatureTemperature value2 Bytes9.1 temperature (°C)CRT
138S1) Coil battery temperatureTemperature value2 Bytes9.1 temperature (°C)CRT
139S1) Antistratification temperatureTemperature value2 Bytes9.1 temperature (°C)CRT
140S1) Outdoor temperatureTemperature value2 Bytes9.1 temperature (°C)CRT
141S1) Floor surface temperatureTemperature value2 Bytes9.1 temperature (°C)CRT
142S1) Generic NTC temperatureTemperature value2 Bytes9.1 temperature (°C)CRT
143S1) Threshold 1Level1 Bit1.1 switchCRT
144S1) Threshold 2Level1 Bit1.1 switchCRT
145S1) Windows contactContact state1 Bit1.19 window/doorCRT
146S1) Anticondensation contactContact state1 Bit1.5 alarmCRT
147S1) Card holder contactContact state1 Bit1.18 occupancyCRT
148S1) Presence contactContact state1 Bit1.18 occupancyCRT
149S2) Room temperatureTemperature value2 Bytes9.1 temperature (°C)CRT
150S2) Coil battery temperatureTemperature value2 Bytes9.1 temperature (°C)CRT
151S2) Antistratification temperatureTemperature value2 Bytes9.1 temperature (°C)CRT
152S2) Outdoor temperatureTemperature value2 Bytes9.1 temperature (°C)CRT
153S2) Floor surface temperatureTemperature value2 Bytes9.1 temperature (°C)CRT
154S2) Generic NTC temperatureTemperature value2 Bytes9.1 temperature (°C)CRT
155S2) Threshold 1Level1 Bit1.1 switchCRT
156S2) Threshold 2Level1 Bit1.1 switchCRT
157S2) Windows contactContact state1 Bit1.19 window/doorCRT
158S2) Anticondensation contactContact state1 Bit1.5 alarmCRT
159S2) Card holder contactContact state1 Bit1.18 occupancyCRT
160S2) Presence contactContact state1 Bit1.18 occupancyCRT
161S3) Room temperatureTemperature value2 Bytes9.1 temperature (°C)CRT
162S3) Coil battery temperature Temperature value2 Bytes9.1 temperature (°C)CRT
163S3) Antistratification temperatureTemperature value2 Bytes9.1 temperature (°C)CRT
164S3) Outdoor temperatureTemperature value2 Bytes9.1 temperature (°C)CRT
165S3) Floor surface temperatureTemperature value2 Bytes9.1 temperature (°C)CRT
166S3) Generic NTC temperatureTemperature value2 Bytes9.1 temperature (°C)CRT
167S3) Threshold 1Level1 Bit1.1 switchCRT
168S3) Threshold 2Level1 Bit1.1 switchCRT
169S3) Windows contactContact state1 Bit1.19 window/doorCRT
170S3) Anticondensation contactContact state1 Bit1.5 alarmCRT
171S3) Card holder contactContact state1 Bit1.18 occupancyCRT
172S3) Presence contactContact state1 Bit1.18 occupancyCRT
173Average temperatureTemperature value2 Bytes9.1 temperature (°C)CRT
174Average humidityHumidity value - 1 Byte1 Byte5.1 percentage (0..100%)CRT
175Average humidityHumidity value - 2 byte2 Bytes9.7 humidity (%)CRT
176Scene A1Enable lock function1 Bit1.3 enableCWU
177Scene A1State lock1 Bit1.11 stateCRT
178Scene A1Action 1 (Short press) - Switch1 Bit1.1 switchCT
178Scene A1Action 1 (Short press) - Move1 Bit1.8 up/downCT
178Scene A1Action 1 (Short press) - Call1 Byte17.1 scene numberCT
178Scene A1Action 1 (Short press) - Value1 Byte5.10 counter pulses (0..255)CT
178Scene A1Action 1 (Short press) - Percentage value1 Byte5.4 percentage (0..255%)CT
178Scene A1Action 1 (Short press) - HVAC1 Byte20.102 HVAC modeCT
179Scene A1Action 2 (Short press) - Switch1 Bit1.1 switchCT
179Scene A1Action 2 (Short press) - Move1 Bit1.8 up/downCT
179Scene A1Action 2 (Short press) - Call1 Byte17.1 scene numberCT
179Scene A1Action 2 (Short press) - Value1 Byte5.10 counter pulses (0..255)CT
179Scene A1Action 2 (Short press) - Percentage value1 Byte5.4 percentage (0..255%)CT
179Scene A1Action 2 (Short press) - HVAC1 Byte20.102 HVAC modeCT
180Scene A1Action 3 (Short press) - Switch1 Bit1.1 switchCT
180Scene A1Action 3 (Short press) - Move1 Bit1.8 up/downCT
180Scene A1Action 3 (Short press) - Call1 Byte17.1 scene numberCT
180Scene A1Action 3 (Short press) - Value1 Byte5.10 counter pulses (0..255)CT
180Scene A1Action 3 (Short press) - Percentage value1 Byte5.4 percentage (0..255%)CT
180Scene A1Action 3 (Short press) - HVAC1 Byte20.102 HVAC modeCT
181Scene A1Action 1 (Long press) - Switch1 Bit1.1 switchCT
181Scene A1Action 1 (Long press) - Move1 Bit1.8 up/downCT
181Scene A1Action 1 (Long press) - Call1 Byte17.1 scene numberCT
181Scene A1Action 1 (Long press) - Save1 Byte18.1 scene controlCT
181Scene A1Action 1 (Long press) - Value1 Byte5.10 counter pulses (0..255)CT
181Scene A1Action 1 (Long press) - Percentage value1 Byte5.4 percentage (0..255%)CT
181Scene A1Action 1 (Long press) - HVAC1 Byte20.102 HVAC modeCT
182Scene A1Action 2 (Long press) - Switch1 Bit1.1 switchCT
182Scene A1Action 2 (Long press) - Move1 Bit1.8 up/downCT
182Scene A1Action 2 (Long press) - Call1 Byte17.1 scene numberCT
182Scene A1Action 2 (Long press) - Save1 Byte18.1 scene controlCT
182Scene A1Action 2 (Long press) - Value1 Byte5.10 counter pulses (0..255)CT
182Scene A1Action 2 (Long press) - Percentage value1 Byte5.4 percentage (0..255%)CT
182Scene A1Action 2 (Long press) - HVAC1 Byte20.102 HVAC modeCT
183Scene A1Action 3 (Long press) - Switch1 Bit1.1 switchCT
183Scene A1Action 3 (Long press) - Move1 Bit1.8 up/downCT
183Scene A1Action 3 (Long press) - Call1 Byte17.1 scene numberCT
183Scene A1Action 3 (Long press) - Save1 Byte18.1 scene controlCT
183Scene A1Action 3 (Long press) - Value1 Byte5.10 counter pulses (0..255)CT
183Scene A1Action 3 (Long press) - Percentage value1 Byte5.4 percentage (0..255%)CT
183Scene A1Action 3 (Long press) - HVAC1 Byte20.102 HVAC modeCT
184Scene A2Enable lock function1 Bit1.3 enableCWU
185Scene A2State lock1 Bit1.11 stateCRT
186Scene A2Action 1 (Short press) - Switch1 Bit1.1 switchCT
186Scene A2Action 1 (Short press) - Move1 Bit1.8 up/downCT
186Scene A2Action 1 (Short press) - Call1 Byte17.1 scene numberCT
186Scene A2Action 1 (Short press) - Value1 Byte5.10 counter pulses (0..255)CT
186Scene A2Action 1 (Short press) - Percentage value1 Byte5.4 percentage (0..255%)CT
186Scene A2Action 1 (Short press) - HVAC1 Byte20.102 HVAC modeCT
187Scene A2Action 2 (Short press) - Switch1 Bit1.1 switchCT
187Scene A2Action 2 (Short press) - Move1 Bit1.8 up/downCT
187Scene A2Action 2 (Short press) - Call1 Byte17.1 scene numberCT
187Scene A2Action 2 (Short press) - Value1 Byte5.10 counter pulses (0..255)CT
187Scene A2Action 2 (Short press) - Percentage value1 Byte5.4 percentage (0..255%)CT
187Scene A2Action 2 (Short press) - HVAC1 Byte20.102 HVAC modeCT
188Scene A2Action 3 (Short press) - Switch1 Bit1.1 switchCT
188Scene A2Action 3 (Short press) - Move1 Bit1.8 up/downCT
188Scene A2Action 3 (Short press) - Call1 Byte17.1 scene numberCT
188Scene A2Action 3 (Short press) - Value1 Byte5.10 counter pulses (0..255)CT
188Scene A2Action 3 (Short press) - Percentage value1 Byte5.4 percentage (0..255%)CT
188Scene A2Action 3 (Short press) - HVAC1 Byte20.102 HVAC modeCT
189Scene A2Action 1 (Long press) - Switch1 Bit1.1 switchCT
189Scene A2Action 1 (Long press) - Move1 Bit1.8 up/downCT
189Scene A2Action 1 (Long press) - Call1 Byte17.1 scene numberCT
189Scene A2Action 1 (Long press) - Save1 Byte18.1 scene controlCT
189Scene A2Action 1 (Long press) - Value1 Byte5.10 counter pulses (0..255)CT
189Scene A2Action 1 (Long press) - Percentage value1 Byte5.4 percentage (0..255%)CT
189Scene A2Action 1 (Long press) - HVAC1 Byte20.102 HVAC modeCT
190Scene A2Action 2 (Long press) - Switch1 Bit1.1 switchCT
190Scene A2Action 2 (Long press) - Move1 Bit1.8 up/downCT
190Scene A2Action 2 (Long press) - Call1 Byte17.1 scene numberCT
190Scene A2Action 2 (Long press) - Save1 Byte18.1 scene controlCT
190Scene A2Action 2 (Long press) - Value1 Byte5.10 counter pulses (0..255)CT
190Scene A2Action 2 (Long press) - Percentage value1 Byte5.4 percentage (0..255%)CT
190Scene A2Action 2 (Long press) - HVAC1 Byte20.102 HVAC modeCT
191Scene A2Action 3 (Long press) - Switch1 Bit1.1 switchCT
191Scene A2Action 3 (Long press) - Move1 Bit1.8 up/downCT
191Scene A2Action 3 (Long press) - Call1 Byte17.1 scene numberCT
191Scene A2Action 3 (Long press) - Save1 Byte18.1 scene controlCT
191Scene A2Action 3 (Long press) - Value1 Byte5.10 counter pulses (0..255)CT
191Scene A2Action 3 (Long press) - Percentage value1 Byte5.4 percentage (0..255%)CT
191Scene A2Action 3 (Long press) - HVAC1 Byte20.102 HVAC modeCT
192Scene A3Enable lock function1 Bit1.3 enableCWU
193Scene A3State lock1 Bit1.11 stateCRT
194Scene A3Action 1 (Short press) - Switch1 Bit1.1 switchCT
194Scene A3Action 1 (Short press) - Move1 Bit1.8 up/downCT
194Scene A3Action 1 (Short press) - Call1 Byte17.1 scene numberCT
194Scene A3Action 1 (Short press) - Value1 Byte5.10 counter pulses (0..255)CT
194Scene A3Action 1 (Short press) - Percentage value1 Byte5.4 percentage (0..255%)CT
194Scene A3Action 1 (Short press) - HVAC1 Byte20.102 HVAC modeCT
195Scene A3Action 2 (Short press) - Switch1 Bit1.1 switchCT
195Scene A3Action 2 (Short press) - Move1 Bit1.8 up/downCT
195Scene A3Action 2 (Short press) - Call1 Byte17.1 scene numberCT
195Scene A3Action 2 (Short press) - Value1 Byte5.10 counter pulses (0..255)CT
195Scene A3Action 2 (Short press) - Percentage value1 Byte5.4 percentage (0..255%)CT
195Scene A3Action 2 (Short press) - HVAC1 Byte20.102 HVAC modeCT
196Scene A3Action 3 (Short press) - Switch1 Bit1.1 switchCT
196Scene A3Action 3 (Short press) - Move1 Bit1.8 up/downCT
196Scene A3Action 3 (Short press) - Call1 Byte17.1 scene numberCT
196Scene A3Action 3 (Short press) - Value1 Byte5.10 counter pulses (0..255)CT
196Scene A3Action 3 (Short press) - Percentage value1 Byte5.4 percentage (0..255%)CT
196Scene A3Action 3 (Short press) - HVAC1 Byte20.102 HVAC modeCT
197Scene A3Action 1 (Long press) - Switch1 Bit1.1 switchCT
197Scene A3Action 1 (Long press) - Move1 Bit1.8 up/downCT
197Scene A3Action 1 (Long press) - Call1 Byte17.1 scene numberCT
197Scene A3Action 1 (Long press) - Save1 Byte18.1 scene controlCT
197Scene A3Action 1 (Long press) - Value1 Byte5.10 counter pulses (0..255)CT
197Scene A3Action 1 (Long press) - Percentage value1 Byte5.4 percentage (0..255%)CT
197Scene A3Action 1 (Long press) - HVAC1 Byte20.102 HVAC modeCT
198Scene A3Action 2 (Long press) - Switch1 Bit1.1 switchCT
198Scene A3Action 2 (Long press) - Move1 Bit1.8 up/downCT
198Scene A3Action 2 (Long press) - Call1 Byte17.1 scene numberCT
198Scene A3Action 2 (Long press) - Save1 Byte18.1 scene controlCT
198Scene A3Action 2 (Long press) - Value1 Byte5.10 counter pulses (0..255)CT
198Scene A3Action 2 (Long press) - Percentage value1 Byte5.4 percentage (0..255%)CT
198Scene A3Action 2 (Long press) - HVAC1 Byte20.102 HVAC modeCT
199Scene A3Action 3 (Long press) - Switch1 Bit1.1 switchCT
199Scene A3Action 3 (Long press) - Move1 Bit1.8 up/downCT
199Scene A3Action 3 (Long press) - Call1 Byte17.1 scene numberCT
199Scene A3Action 3 (Long press) - Save1 Byte18.1 scene controlCT
199Scene A3Action 3 (Long press) - Value1 Byte5.10 counter pulses (0..255)CT
199Scene A3Action 3 (Long press) - Percentage value1 Byte5.4 percentage (0..255%)CT
199Scene A3Action 3 (Long press) - HVAC1 Byte20.102 HVAC modeCT
200Scene A4Enable lock function1 Bit1.3 enableCWU
201Scene A4State lock1 Bit1.11 stateCRT
202Scene A4Action 1 (Short press) - Switch1 Bit1.1 switchCT
202Scene A4Action 1 (Short press) - Move1 Bit1.8 up/downCT
202Scene A4Action 1 (Short press) - Call1 Byte17.1 scene numberCT
202Scene A4Action 1 (Short press) - Value1 Byte5.10 counter pulses (0..255)CT
202Scene A4Action 1 (Short press) - Percentage value1 Byte5.4 percentage (0..255%)CT
202Scene A4Action 1 (Short press) - HVAC1 Byte20.102 HVAC modeCT
203Scene A4Action 2 (Short press) - Switch1 Bit1.1 switchCT
203Scene A4Action 2 (Short press) - Move1 Bit1.8 up/downCT
203Scene A4Action 2 (Short press) - Call1 Byte17.1 scene numberCT
203Scene A4Action 2 (Short press) - Value1 Byte5.10 counter pulses (0..255)CT
203Scene A4Action 2 (Short press) - Percentage value1 Byte5.4 percentage (0..255%)CT
203Scene A4Action 2 (Short press) - HVAC1 Byte20.102 HVAC modeCT
204Scene A4Action 3 (Short press) - Switch1 Bit1.1 switchCT
204Scene A4Action 3 (Short press) - Move1 Bit1.8 up/downCT
204Scene A4Action 3 (Short press) - Call1 Byte17.1 scene numberCT
204Scene A4Action 3 (Short press) - Value1 Byte5.10 counter pulses (0..255)CT
204Scene A4Action 3 (Short press) - Percentage value1 Byte5.4 percentage (0..255%)CT
204Scene A4Action 3 (Short press) - HVAC1 Byte20.102 HVAC modeCT
205Scene A4Action 1 (Long press) - Switch1 Bit1.1 switchCT
205Scene A4Action 1 (Long press) - Move1 Bit1.8 up/downCT
205Scene A4Action 1 (Long press) - Call1 Byte17.1 scene numberCT
205Scene A4Action 1 (Long press) - Save1 Byte18.1 scene controlCT
205Scene A4Action 1 (Long press) - Value1 Byte5.10 counter pulses (0..255)CT
205Scene A4Action 1 (Long press) - Percentage value1 Byte5.4 percentage (0..255%)CT
205Scene A4Action 1 (Long press) - HVAC1 Byte20.102 HVAC modeCT
206Scene A4Action 2 (Long press) - Switch1 Bit1.1 switchCT
206Scene A4Action 2 (Long press) - Move1 Bit1.8 up/downCT
206Scene A4Action 2 (Long press) - Call1 Byte17.1 scene numberCT
206Scene A4Action 2 (Long press) - Save1 Byte18.1 scene controlCT
206Scene A4Action 2 (Long press) - Value1 Byte5.10 counter pulses (0..255)CT
206Scene A4Action 2 (Long press) - Percentage value1 Byte5.4 percentage (0..255%)CT
206Scene A4Action 2 (Long press) - HVAC1 Byte20.102 HVAC modeCT
207Scene A4Action 3 (Long press) - Switch1 Bit1.1 switchCT
207Scene A4Action 3 (Long press) - Move1 Bit1.8 up/downCT
207Scene A4Action 3 (Long press) - Call1 Byte17.1 scene numberCT
207Scene A4Action 3 (Long press) - Save1 Byte18.1 scene controlCT
207Scene A4Action 3 (Long press) - Value1 Byte5.10 counter pulses (0..255)CT
207Scene A4Action 3 (Long press) - Percentage value1 Byte5.4 percentage (0..255%)CT
207Scene A4Action 3 (Long press) - HVAC1 Byte20.102 HVAC modeCT
208Scene B1Enable lock function1 Bit1.3 enableCWU
209Scene B1State lock1 Bit1.11 stateCRT
210Scene B1Action 1 (Short press) - Switch1 Bit1.1 switchCT
210Scene B1Action 1 (Short press) - Move1 Bit1.8 up/downCT
210Scene B1Action 1 (Short press) - Call1 Byte17.1 scene numberCT
210Scene B1Action 1 (Short press) - Value1 Byte5.10 counter pulses (0..255)CT
210Scene B1Action 1 (Short press) - Percentage value1 Byte5.4 percentage (0..255%)CT
210Scene B1Action 1 (Short press) - HVAC1 Byte20.102 HVAC modeCT
211Scene B1Action 2 (Short press) - Switch1 Bit1.1 switchCT
211Scene B1Action 2 (Short press) - Move1 Bit1.8 up/downCT
211Scene B1Action 2 (Short press) - Call1 Byte17.1 scene numberCT
211Scene B1Action 2 (Short press) - Value1 Byte5.10 counter pulses (0..255)CT
211Scene B1Action 2 (Short press) - Percentage value1 Byte5.4 percentage (0..255%)CT
211Scene B1Action 2 (Short press) - HVAC1 Byte20.102 HVAC modeCT
212Scene B1Action 3 (Short press) - Switch1 Bit1.1 switchCT
212Scene B1Action 3 (Short press) - Move1 Bit1.8 up/downCT
212Scene B1Action 3 (Short press) - Call1 Byte17.1 scene numberCT
212Scene B1Action 3 (Short press) - Value1 Byte5.10 counter pulses (0..255)CT
212Scene B1Action 3 (Short press) - Percentage value1 Byte5.4 percentage (0..255%)CT
212Scene B1Action 3 (Short press) - HVAC1 Byte20.102 HVAC modeCT
213Scene B1Action 1 (Long press) - Switch1 Bit1.1 switchCT
213Scene B1Action 1 (Long press) - Move1 Bit1.8 up/downCT
213Scene B1Action 1 (Long press) - Call1 Byte17.1 scene numberCT
213Scene B1Action 1 (Long press) - Save1 Byte18.1 scene controlCT
213Scene B1Action 1 (Long press) - Value1 Byte5.10 counter pulses (0..255)CT
213Scene B1Action 1 (Long press) - Percentage value1 Byte5.4 percentage (0..255%)CT
213Scene B1Action 1 (Long press) - HVAC1 Byte20.102 HVAC modeCT
214Scene B1Action 2 (Long press) - Switch1 Bit1.1 switchCT
214Scene B1Action 2 (Long press) - Move1 Bit1.8 up/downCT
214Scene B1Action 2 (Long press) - Call1 Byte17.1 scene numberCT
214Scene B1Action 2 (Long press) - Save1 Byte18.1 scene controlCT
214Scene B1Action 2 (Long press) - Value1 Byte5.10 counter pulses (0..255)CT
214Scene B1Action 2 (Long press) - Percentage value1 Byte5.4 percentage (0..255%)CT
214Scene B1Action 2 (Long press) - HVAC1 Byte20.102 HVAC modeCT
215Scene B1Action 3 (Long press) - Switch1 Bit1.1 switchCT
215Scene B1Action 3 (Long press) - Move1 Bit1.8 up/downCT
215Scene B1Action 3 (Long press) - Call1 Byte17.1 scene numberCT
215Scene B1Action 3 (Long press) - Save1 Byte18.1 scene controlCT
215Scene B1Action 3 (Long press) - Value1 Byte5.10 counter pulses (0..255)CT
215Scene B1Action 3 (Long press) - Percentage value1 Byte5.4 percentage (0..255%)CT
215Scene B1Action 3 (Long press) - HVAC1 Byte20.102 HVAC modeCT
216Scene B2Enable lock function1 Bit1.3 enableCWU
217Scene B2State lock1 Bit1.11 stateCRT
218Scene B2Action 1 (Short press) - Switch1 Bit1.1 switchCT
218Scene B2Action 1 (Short press) - Move1 Bit1.8 up/downCT
218Scene B2Action 1 (Short press) - Call1 Byte17.1 scene numberCT
218Scene B2Action 1 (Short press) - Value1 Byte5.10 counter pulses (0..255)CT
218Scene B2Action 1 (Short press) - Percentage value1 Byte5.4 percentage (0..255%)CT
218Scene B2Action 1 (Short press) - HVAC1 Byte20.102 HVAC modeCT
219Scene B2Action 2 (Short press) - Switch1 Bit1.1 switchCT
219Scene B2Action 2 (Short press) - Move1 Bit1.8 up/downCT
219Scene B2Action 2 (Short press) - Call1 Byte17.1 scene numberCT
219Scene B2Action 2 (Short press) - Value1 Byte5.10 counter pulses (0..255)CT
219Scene B2Action 2 (Short press) - Percentage value1 Byte5.4 percentage (0..255%)CT
219Scene B2Action 2 (Short press) - HVAC1 Byte20.102 HVAC modeCT
220Scene B2Action 3 (Short press) - Switch1 Bit1.1 switchCT
220Scene B2Action 3 (Short press) - Move1 Bit1.8 up/downCT
220Scene B2Action 3 (Short press) - Call1 Byte17.1 scene numberCT
220Scene B2Action 3 (Short press) - Value1 Byte5.10 counter pulses (0..255)CT
220Scene B2Action 3 (Short press) - Percentage value1 Byte5.4 percentage (0..255%)CT
220Scene B2Action 3 (Short press) - HVAC1 Byte20.102 HVAC modeCT
221Scene B2Action 1 (Long press) - Switch1 Bit1.1 switchCT
221Scene B2Action 1 (Long press) - Move1 Bit1.8 up/downCT
221Scene B2Action 1 (Long press) - Call1 Byte17.1 scene numberCT
221Scene B2Action 1 (Long press) - Save1 Byte18.1 scene controlCT
221Scene B2Action 1 (Long press) - Value1 Byte5.10 counter pulses (0..255)CT
221Scene B2Action 1 (Long press) - Percentage value1 Byte5.4 percentage (0..255%)CT
221Scene B2Action 1 (Long press) - HVAC1 Byte20.102 HVAC modeCT
222Scene B2Action 2 (Long press) - Switch1 Bit1.1 switchCT
222Scene B2Action 2 (Long press) - Move1 Bit1.8 up/downCT
222Scene B2Action 2 (Long press) - Call1 Byte17.1 scene numberCT
222Scene B2Action 2 (Long press) - Save1 Byte18.1 scene controlCT
222Scene B2Action 2 (Long press) - Value1 Byte5.10 counter pulses (0..255)CT
222Scene B2Action 2 (Long press) - Percentage value1 Byte5.4 percentage (0..255%)CT
222Scene B2Action 2 (Long press) - HVAC1 Byte20.102 HVAC modeCT
223Scene B2Action 3 (Long press) - Switch1 Bit1.1 switchCT
223Scene B2Action 3 (Long press) - Move1 Bit1.8 up/downCT
223Scene B2Action 3 (Long press) - Call1 Byte17.1 scene numberCT
223Scene B2Action 3 (Long press) - Save1 Byte18.1 scene controlCT
223Scene B2Action 3 (Long press) - Value1 Byte5.10 counter pulses (0..255)CT
223Scene B2Action 3 (Long press) - Percentage value1 Byte5.4 percentage (0..255%)CT
223Scene B2Action 3 (Long press) - HVAC1 Byte20.102 HVAC modeCT
224Scene B3Enable lock function1 Bit1.3 enableCWU
225Scene B3State lock1 Bit1.11 stateCRT
226Scene B3Action 1 (Short press) - Switch1 Bit1.1 switchCT
226Scene B3Action 1 (Short press) - Move1 Bit1.8 up/downCT
226Scene B3Action 1 (Short press) - Call1 Byte17.1 scene numberCT
226Scene B3Action 1 (Short press) - Value1 Byte5.10 counter pulses (0..255)CT
226Scene B3Action 1 (Short press) - Percentage value1 Byte5.4 percentage (0..255%)CT
226Scene B3Action 1 (Short press) - HVAC1 Byte20.102 HVAC modeCT
227Scene B3Action 2 (Short press) - Switch1 Bit1.1 switchCT
227Scene B3Action 2 (Short press) - Move1 Bit1.8 up/downCT
227Scene B3Action 2 (Short press) - Call1 Byte17.1 scene numberCT
227Scene B3Action 2 (Short press) - Value1 Byte5.10 counter pulses (0..255)CT
227Scene B3Action 2 (Short press) - Percentage value1 Byte5.4 percentage (0..255%)CT
227Scene B3Action 2 (Short press) - HVAC1 Byte20.102 HVAC modeCT
228Scene B3Action 3 (Short press) - Switch1 Bit1.1 switchCT
228Scene B3Action 3 (Short press) - Move1 Bit1.8 up/downCT
228Scene B3Action 3 (Short press) - Call1 Byte17.1 scene numberCT
228Scene B3Action 3 (Short press) - Value1 Byte5.10 counter pulses (0..255)CT
228Scene B3Action 3 (Short press) - Percentage value1 Byte5.4 percentage (0..255%)CT
228Scene B3Action 3 (Short press) - HVAC1 Byte20.102 HVAC modeCT
229Scene B3Action 1 (Long press) - Switch1 Bit1.1 switchCT
229Scene B3Action 1 (Long press) - Move1 Bit1.8 up/downCT
229Scene B3Action 1 (Long press) - Call1 Byte17.1 scene numberCT
229Scene B3Action 1 (Long press) - Save1 Byte18.1 scene controlCT
229Scene B3Action 1 (Long press) - Value1 Byte5.10 counter pulses (0..255)CT
229Scene B3Action 1 (Long press) - Percentage value1 Byte5.4 percentage (0..255%)CT
229Scene B3Action 1 (Long press) - HVAC1 Byte20.102 HVAC modeCT
230Scene B3Action 2 (Long press) - Switch1 Bit1.1 switchCT
230Scene B3Action 2 (Long press) - Move1 Bit1.8 up/downCT
230Scene B3Action 2 (Long press) - Call1 Byte17.1 scene numberCT
230Scene B3Action 2 (Long press) - Save1 Byte18.1 scene controlCT
230Scene B3Action 2 (Long press) - Value1 Byte5.10 counter pulses (0..255)CT
230Scene B3Action 2 (Long press) - Percentage value1 Byte5.4 percentage (0..255%)CT
230Scene B3Action 2 (Long press) - HVAC1 Byte20.102 HVAC modeCT
231Scene B3Action 3 (Long press) - Switch1 Bit1.1 switchCT
231Scene B3Action 3 (Long press) - Move1 Bit1.8 up/downCT
231Scene B3Action 3 (Long press) - Call1 Byte17.1 scene numberCT
231Scene B3Action 3 (Long press) - Save1 Byte18.1 scene controlCT
231Scene B3Action 3 (Long press) - Value1 Byte5.10 counter pulses (0..255)CT
231Scene B3Action 3 (Long press) - Percentage value1 Byte5.4 percentage (0..255%)CT
231Scene B3Action 3 (Long press) - HVAC1 Byte20.102 HVAC modeCT
232Scene B4Enable lock function1 Bit1.3 enableCWU
233Scene B4State lock1 Bit1.11 stateCRT
234Scene B4Action 1 (Short press) - Switch1 Bit1.1 switchCT
234Scene B4Action 1 (Short press) - Move1 Bit1.8 up/downCT
234Scene B4Action 1 (Short press) - Call1 Byte17.1 scene numberCT
234Scene B4Action 1 (Short press) - Value1 Byte5.10 counter pulses (0..255)CT
234Scene B4Action 1 (Short press) - Percentage value1 Byte5.4 percentage (0..255%)CT
234Scene B4Action 1 (Short press) - HVAC1 Byte20.102 HVAC modeCT
235Scene B4Action 2 (Short press) - Switch1 Bit1.1 switchCT
235Scene B4Action 2 (Short press) - Move1 Bit1.8 up/downCT
235Scene B4Action 2 (Short press) - Call1 Byte17.1 scene numberCT
235Scene B4Action 2 (Short press) - Value1 Byte5.10 counter pulses (0..255)CT
235Scene B4Action 2 (Short press) - Percentage value1 Byte5.4 percentage (0..255%)CT
235Scene B4Action 2 (Short press) - HVAC1 Byte20.102 HVAC modeCT
236Scene B4Action 3 (Short press) - Switch1 Bit1.1 switchCT
236Scene B4Action 3 (Short press) - Move1 Bit1.8 up/downCT
236Scene B4Action 3 (Short press) - Call1 Byte17.1 scene numberCT
236Scene B4Action 3 (Short press) - Value1 Byte5.10 counter pulses (0..255)CT
236Scene B4Action 3 (Short press) - Percentage value1 Byte5.4 percentage (0..255%)CT
236Scene B4Action 3 (Short press) - HVAC1 Byte20.102 HVAC modeCT
237Scene B4Action 1 (Long press) - Switch1 Bit1.1 switchCT
237Scene B4Action 1 (Long press) - Move1 Bit1.8 up/downCT
237Scene B4Action 1 (Long press) - Call1 Byte17.1 scene numberCT
237Scene B4Action 1 (Long press) - Save1 Byte18.1 scene controlCT
237Scene B4Action 1 (Long press) - Value1 Byte5.10 counter pulses (0..255)CT
237Scene B4Action 1 (Long press) - Percentage value1 Byte5.4 percentage (0..255%)CT
237Scene B4Action 1 (Long press) - HVAC1 Byte20.102 HVAC modeCT
238Scene B4Action 2 (Long press) - Switch1 Bit1.1 switchCT
238Scene B4Action 2 (Long press) - Move1 Bit1.8 up/downCT
238Scene B4Action 2 (Long press) - Call1 Byte17.1 scene numberCT
238Scene B4Action 2 (Long press) - Save1 Byte18.1 scene controlCT
238Scene B4Action 2 (Long press) - Value1 Byte5.10 counter pulses (0..255)CT
238Scene B4Action 2 (Long press) - Percentage value1 Byte5.4 percentage (0..255%)CT
238Scene B4Action 2 (Long press) - HVAC1 Byte20.102 HVAC modeCT
239Scene B4Action 3 (Long press) - Switch1 Bit1.1 switchCT
239Scene B4Action 3 (Long press) - Move1 Bit1.8 up/downCT
239Scene B4Action 3 (Long press) - Call1 Byte17.1 scene numberCT
239Scene B4Action 3 (Long press) - Save1 Byte18.1 scene controlCT
239Scene B4Action 3 (Long press) - Value1 Byte5.10 counter pulses (0..255)CT
239Scene B4Action 3 (Long press) - Percentage value1 Byte5.4 percentage (0..255%)CT
239Scene B4Action 3 (Long press) - HVAC1 Byte20.102 HVAC modeCT
240Light A1Switch command1 Bit1.1 switchCRWTU
241Light A1Enable lock function1 Bit1.3 enableCWU
242Light A1State lock1 Bit1.11 stateCRT
243Light A1State On/Off1 Bit1.1 switchCWTU
244Light A1Dimming regulation4 Bit3.7 dimming controlCRWTU
245Light A1Dimming feedback1 Byte5.1 percentage (0..100%)CWTU
246Light A1Dimming level1 Byte5.1 percentage (0..100%)CT
247Light A2 Switch command1 Bit1.1 switchCRWTU
248Light A2Enable lock function1 Bit1.3 enableCWU
249Light A2State lock1 Bit1.11 stateCRT
250Light A2State On/Off1 Bit1.1 switchCWTU
251Light A2Dimming regulation4 Bit3.7 dimming controlCRWTU
252Light A2Dimming feedback1 Byte5.1 percentage (0..100%)CWTU
253Light A2Dimming level1 Byte5.1 percentage (0..100%)CT
254Light A3Switch command1 Bit1.1 switchCRWTU
255Light A3Enable lock function1 Bit1.3 enableCWU
256Light A3State lock1 Bit1.11 stateCRT
257Light A3State On/Off1 Bit1.1 switchCWTU
258Light A3Dimming regulation4 Bit3.7 dimming controlCRWTU
259Light A3Dimming feedback1 Byte5.1 percentage (0..100%)CWTU
260Light A3Dimming level1 Byte5.1 percentage (0..100%)CT
261Light A4Switch command1 Bit1.1 switchCRWTU
262Light A4Enable lock function1 Bit1.3 enableCWU
263Light A4State lock1 Bit1.11 stateCRT
264Light A4State On/Off1 Bit1.1 switchCWTU
265Light A4Dimming regulation4 Bit3.7 dimming controlCRWTU
266Light A4Dimming feedback1 Byte5.1 percentage (0..100%)CWTU
267Light A4Dimming level1 Byte5.1 percentage (0..100%)CT
268Light A5Switch command1 Bit1.1 switchCRWTU
269Light A5Enable lock function1 Bit1.3 enableCWU
270Light A5State lock1 Bit1.11 stateCRT
271Light A5State On/Off1 Bit1.1 switchCWTU
272Light A5Dimming regulation4 Bit3.7 dimming controlCRWTU
273Light A5Dimming feedback1 Byte5.1 percentage (0..100%)CWTU
274Light A5Dimming level1 Byte5.1 percentage (0..100%)CT
275Light A6Switch command1 Bit1.1 switchCRWTU
276Light A6Enable lock function1 Bit1.3 enableCWU
277Light A6State lock1 Bit1.11 stateCRT
278Light A6State On/Off1 Bit1.1 switchCWTU
279Light A6Dimming regulation4 Bit3.7 dimming controlCRWTU
280Light A6Dimming feedback1 Byte5.1 percentage (0..100%)CWTU
281Light A6Dimming level1 Byte5.1 percentage (0..100%)CT
282Light B1Switch command1 Bit1.1 switchCRWTU
283Light B1Enable lock function1 Bit1.3 enableCWU
284Light B1State lock1 Bit1.11 stateCRT
285Light B1State On/Off1 Bit1.1 switchCWTU
286Light B1Dimming regulation4 Bit3.7 dimming controlCRWTU
287Light B1Dimming feedback1 Byte5.1 percentage (0..100%)CWTU
288Light B1Dimming level1 Byte5.1 percentage (0..100%)CT
289Light B2Switch command1 Bit1.1 switchCRWTU
290Light B2Enable lock function1 Bit1.3 enableCWU
291Light B2State lock1 Bit1.11 stateCRT
292Light B2State On/Off1 Bit1.1 switchCWTU
293Light B2Dimming regulation4 Bit3.7 dimming controlCRWTU
294Light B2Dimming feedback1 Byte5.1 percentage (0..100%)CWTU
295Light B2Dimming level1 Byte5.1 percentage (0..100%)CT
296Light B3Switch command1 Bit1.1 switchCRWTU
297Light B3Enable lock function1 Bit1.3 enableCWU
298Light B3State lock1 Bit1.11 stateCRT
299Light B3State On/Off1 Bit1.1 switchCWTU
300Light B3Dimming regulation4 Bit3.7 dimming controlCRWTU
301Light B3Dimming feedback1 Byte5.1 percentage (0..100%)CWTU
302Light B3Dimming level1 Byte5.1 percentage (0..100%)CT
303Light B4Switch command1 Bit1.1 switchCRWTU
304Light B4Enable lock function1 Bit1.3 enableCWU
305Light B4State lock1 Bit1.11 stateCRT
306Light B4State On/Off1 Bit1.1 switchCWTU
307Light B4Dimming regulation4 Bit3.7 dimming controlCRWTU
308Light B4Dimming feedback1 Byte5.1 percentage (0..100%)CWTU
309Light B4Dimming level1 Byte5.1 percentage (0..100%)CT
310Light B5Switch command1 Bit1.1 switchCRWTU
311Light B5Enable lock function1 Bit1.3 enableCWU
312Light B5State lock1 Bit1.11 stateCRT
313Light B5State On/Off1 Bit1.1 switchCWTU
314Light B5Dimming regulation4 Bit3.7 dimming controlCRWTU
315Light B5Dimming feedback1 Byte5.1 percentage (0..100%)CWTU
316Light B5Dimming level1 Byte5.1 percentage (0..100%)CT
317Light B6Switch command1 Bit1.1 switchCRWTU
318Light B6Enable lock function1 Bit1.3 enableCWU
319Light B6State lock1 Bit1.11 stateCRT
320Light B6State On/Off1 Bit1.1 switchCWTU
321Light B6Dimming regulation4 Bit3.7 dimming controlCRWTU
322Light B6Dimming feedback1 Byte5.1 percentage (0..100%)CWTU
323Light B6Dimming level1 Byte5.1 percentage (0..100%)CT
324Shutter A1Enable lock function1 Bit1.3 enableCWU
325Shutter A1State lock1 Bit1.11 stateCRT
326Shutter A1Step/stop command1 Bit1.7 stepCT
327Shutter A1Move command1 Bit1.8 up/downCRWTU
328Shutter A1Feedback level1 Byte5.1 percentage (0..100%)CWTU
329Shutter A1Feedback Up position1 Bit1.7 stepCWU
330Shutter A1Feedback Down position1 Bit1.7 stepCWU
331Shutter A1Feedback state Up/Down1 Bit1.8 up/downCWU
332Shutter A1Feedback moving Up1 Bit1.7 stepCWU
333Shutter A1Feedback moving Down1 Bit1.7 stepCWU
334Shutter A1Feedback moving Up/Down1 Bit1.8 up/downCWU
335Shutter A2Enable lock function1 Bit1.3 enableCWU
336Shutter A2State lock1 Bit1.11 stateCRT
337Shutter A2Step/stop command1 Bit1.7 stepCT
338Shutter A2Move command1 Bit1.8 up/downCRWTU
339Shutter A2Feedback level1 Byte5.1 percentage (0..100%)CWTU
340Shutter A2Feedback Up position1 Bit1.7 stepCWU
341Shutter A2Feedback Down position1 Bit1.7 stepCWU
342Shutter A2Feedback state Up/Down1 Bit1.8 up/downCWU
343Shutter A2Feedback moving Up1 Bit1.7 stepCWU
344Shutter A2Feedback moving Down1 Bit1.7 stepCWU
345Shutter A2Feedback moving Up/Down1 Bit1.8 up/downCWU
346Shutter A3Enable lock function1 Bit1.3 enableCWU
347Shutter A3State lock1 Bit1.11 stateCRT
348Shutter A3Step/stop command1 Bit1.7 stepCT
349Shutter A3Move command1 Bit1.8 up/downCRWTU
350Shutter A3Feedback level1 Byte5.1 percentage (0..100%)CWTU
351Shutter A3Feedback Up position1 Bit1.7 stepCWU
352Shutter A3Feedback Down position1 Bit1.7 stepCWU
353Shutter A3Feedback state Up/Down1 Bit1.8 up/downCWU
354Shutter A3Feedback moving Up1 Bit1.7 stepCWU
355Shutter A3Feedback moving Down1 Bit1.7 stepCWU
356Shutter A3Feedback moving Up/Down1 Bit1.8 up/downCWU
357Shutter A4Enable lock function1 Bit1.3 enableCWU
358Shutter A4State lock1 Bit1.11 stateCRT
359Shutter A4Step/stop command1 Bit1.7 stepCT
360Shutter A4Move command1 Bit1.8 up/downCRWTU
361Shutter A4Feedback level1 Byte5.1 percentage (0..100%)CWTU
362Shutter A4Feedback Up position1 Bit1.7 stepCWU
363Shutter A4Feedback Down position1 Bit1.7 stepCWU
364Shutter A4Feedback state Up/Down1 Bit1.8 up/downCWU
365Shutter A4Feedback moving Up1 Bit1.7 stepCWU
366Shutter A4Feedback moving Down1 Bit1.7 stepCWU
367Shutter A4Feedback moving Up/Down1 Bit1.8 up/downCWU
368Shutter A5Enable lock function1 Bit1.3 enableCWU
369Shutter A5State lock1 Bit1.11 stateCRT
370Shutter A5Step/stop command1 Bit1.7 stepCT
371Shutter A5Move command1 Bit1.8 up/downCRWTU
372Shutter A5Feedback level1 Byte5.1 percentage (0..100%)CWTU
373Shutter A5Feedback Up position1 Bit1.7 stepCWU
374Shutter A5Feedback Down position1 Bit1.7 stepCWU
375Shutter A5Feedback state Up/Down1 Bit1.8 up/downCWU
376Shutter A5Feedback moving Up1 Bit1.7 stepCWU
377Shutter A5Feedback moving Down1 Bit1.7 stepCWU
378Shutter A5Feedback moving Up/Down1 Bit1.8 up/downCWU
379Shutter A6Enable lock function1 Bit1.3 enableCWU
380Shutter A6State lock1 Bit1.11 stateCRT
381Shutter A6Step/stop command1 Bit1.7 stepCT
382Shutter A6Move command1 Bit1.8 up/downCRWTU
383Shutter A6Feedback level1 Byte5.1 percentage (0..100%)CWTU
384Shutter A6Feedback Up position1 Bit1.7 stepCWU
385Shutter A6Feedback Down position1 Bit1.7 stepCWU
386Shutter A6Feedback state Up/Down1 Bit1.8 up/downCWU
387Shutter A6Feedback moving Up1 Bit1.7 stepCWU
388Shutter A6Feedback moving Down1 Bit1.7 stepCWU
389Shutter A6Feedback moving Up/Down1 Bit1.8 up/downCWU
390Shutter B1Enable lock function1 Bit1.3 enableCWU
391Shutter B1State lock1 Bit1.11 stateCRT
392Shutter B1Step/stop command1 Bit1.7 stepCT
393Shutter B1Move command1 Bit1.8 up/downCRWTU
394Shutter B1Feedback level1 Byte5.1 percentage (0..100%)CWTU
395Shutter B1Feedback Up position1 Bit1.7 stepCWU
396Shutter B1Feedback Down position1 Bit1.7 stepCWU
397Shutter B1Feedback state Up/Down1 Bit1.8 up/downCWU
398Shutter B1Feedback moving Up1 Bit1.7 stepCWU
399Shutter B1Feedback moving Down1 Bit1.7 stepCWU
400Shutter B1Feedback moving Up/Down1 Bit1.8 up/downCWU
401Shutter B2Enable lock function1 Bit1.3 enableCWU
402Shutter B2State lock1 Bit1.11 stateCRT
403Shutter B2Step/stop command1 Bit1.7 stepCT
404Shutter B2Move command1 Bit1.8 up/downCRWTU
405Shutter B2Feedback level1 Byte5.1 percentage (0..100%)CWTU
406Shutter B2Feedback Up position1 Bit1.7 stepCWU
407Shutter B2Feedback Down position1 Bit1.7 stepCWU
408Shutter B2Feedback state Up/Down1 Bit1.8 up/downCWU
409Shutter B2Feedback moving Up1 Bit1.7 stepCWU
410Shutter B2Feedback moving Down1 Bit1.7 stepCWU
411Shutter B2Feedback moving Up/Down1 Bit1.8 up/downCWU
412Shutter B3Enable lock function1 Bit1.3 enableCWU
413Shutter B3State lock1 Bit1.11 stateCRT
414Shutter B3Step/stop command1 Bit1.7 stepCT
415Shutter B3Move command1 Bit1.8 up/downCRWTU
416Shutter B3Feedback level1 Byte5.1 percentage (0..100%)CWTU
417Shutter B3Feedback Up position1 Bit1.7 stepCWU
418Shutter B3Feedback Down position1 Bit1.7 stepCWU
419Shutter B3Feedback state Up/Down1 Bit1.8 up/downCWU
420Shutter B3Feedback moving Up1 Bit1.7 stepCWU
421Shutter B3Feedback moving Down1 Bit1.7 stepCWU
422Shutter B3Feedback moving Up/Down1 Bit1.8 up/downCWU
423Shutter B4Enable lock function1 Bit1.3 enableCWU
424Shutter B4State lock1 Bit1.11 stateCRT
425Shutter B4Step/stop command1 Bit1.7 stepCT
426Shutter B4Move command1 Bit1.8 up/downCRWTU
427Shutter B4Feedback level1 Byte5.1 percentage (0..100%)CWTU
428Shutter B4Feedback Up position1 Bit1.7 stepCWU
429Shutter B4Feedback Down position1 Bit1.7 stepCWU
430Shutter B4Feedback state Up/Down1 Bit1.8 up/downCWU
431Shutter B4Feedback moving Up1 Bit1.7 stepCWU
432Shutter B4Feedback moving Down1 Bit1.7 stepCWU
433Shutter B4Feedback moving Up/Down1 Bit1.8 up/downCWU
434Shutter B5Enable lock function1 Bit1.3 enableCWU
435Shutter B5State lock1 Bit1.11 stateCRT
436Shutter B5Step/stop command1 Bit1.7 stepCT
437Shutter B5Move command1 Bit1.8 up/downCRWTU
438Shutter B5Feedback level1 Byte5.1 percentage (0..100%)CWTU
439Shutter B5Feedback Up position1 Bit1.7 stepCWU
440Shutter B5Feedback Down position1 Bit1.7 stepCWU
441Shutter B5Feedback state Up/Down1 Bit1.8 up/downCWU
442Shutter B5Feedback moving Up1 Bit1.7 stepCWU
443Shutter B5Feedback moving Down1 Bit1.7 stepCWU
444Shutter B5Feedback moving Up/Down1 Bit1.8 up/downCWU
445Shutter B6Enable lock function1 Bit1.3 enableCWU
446Shutter B6State lock1 Bit1.11 stateCRT
447Shutter B6Step/stop command1 Bit1.7 stepCT
448Shutter B6Move command1 Bit1.8 up/downCRWTU
449Shutter B6Feedback level1 Byte5.1 percentage (0..100%)CWTU
450Shutter B6Feedback Up position1 Bit1.7 stepCWU
451Shutter B6Feedback Down position1 Bit1.7 stepCWU
452Shutter B6Feedback state Up/Down1 Bit1.8 up/downCWU
453Shutter B6Feedback moving Up1 Bit1.7 stepCWU
454Shutter B6Feedback moving Down1 Bit1.7 stepCWU
455Shutter B6Feedback moving Up/Down1 Bit1.8 up/downCWU
456MusicEnable lock function1 Bit1.3 enableCWU
457MusicState lock1 Bit1.11 stateCRT
458MusicVolume regulation4 Bit3.7 dimming controlCRT
459MusicVolume Up/Down1 Bit1.1 switchCRT
460MusicVolume feedback1 Byte5.1 percentage (0..100%)CWTU
461MusicSource selection1 Byte5.10 counter pulses (0..255)CRT
462MusicSkip track - Previous/Next1 Bit1.7 stepCRT
463MusicNext track1 Bit1.7 stepCRT
464MusicPrevious track1 Bit1.7 stepCRT
465MusicSource feedback1 Byte5.10 counter pulses (0..255)CWTU
466MusicZone switch on/off1 Bit1.1 switchCRT
467MusicZone on/off feedback state1 Bit1.11 stateCWTU
468Music source 1Switch on/off1 Bit1.1 switchCRT
469Music source 1On/off feedback state1 Bit1.11 stateCWTU
470Music source 2Switch on/off1 Bit1.1 switchCRT
471Music source 2On/off feedback state1 Bit1.11 stateCWTU
472Music source 3Switch on/off1 Bit1.1 switchCRT
473Music source 3On/off feedback state1 Bit1.11 stateCWTU
474Music source 4Switch on/off1 Bit1.1 switchCRT
475Music source 4On/off feedback state1 Bit1.11 stateCWTU
476Music source 5Switch on/off1 Bit1.1 switchCRT
477Music source 5On/off feedback state1 Bit1.11 stateCWTU
478Music source 6Switch on/off1 Bit1.1 switchCRT
479Music source 6On/off feedback state1 Bit1.11 stateCWTU
480Music source 1Text line14 Bytes16.0 Character String (ASCII)CWU
481Music source 2Text line14 Bytes16.0 Character String (ASCII)CWU
482Music source 3Text line14 Bytes16.0 Character String (ASCII)CWU
483Music source 4Text line14 Bytes16.0 Character String (ASCII)CWU
484Music source 5Text line14 Bytes16.0 Character String (ASCII)CWU
485Music source 6Text line14 Bytes16.0 Character String (ASCII)CWU
486MusicMute command1 Bit1.1 switchCRT
487MusicMute feedback1 Bit1.1 switchCWTU
488M) Zone 2 - HumidityHumidification valve state1 Bit1.1 switchCWTU
489M) Zone 2 - HumidityDehumidification valve state1 Bit1.1 switchCWTU
490L) Zone 2 - TemperatureCooling state1 Bit1.1 switchCWTU
491L) Zone 2 - TemperatureHeating state1 Bit1.1 switchCWTU
Parameters (284)
ParameterTypeDefault
RGB Colorcolor#000000
G) Floor temperature probelistDisable
Object datatypelistOne bit data
ConditionlistValue < X
Number Lights Blist1 Light
Feedback priority levellistMin
Sound melodylistMelody 1
S2) External input 2listDisable
Brightness levellistLow
Enable auxiliary ventilationlistDisable
Blinking (Ton = Toff)list0,5 s
Enable scenes A menulistDisable
Value Y 8 bitunsignedInt 0…2550
Display brightnesslistMedium
Cooling type systemlistFancoils
Position threshold 2listDisabled
Enable blinkinglistDisable
Position threshold 1listDisabled
Enable auxiliary coolinglistDisable
I) CO2 probelistDisable
Value X 8 bitunsignedInt 0…2550
Value X 16 bitunsignedInt 0…655350
Invert conditionlistDisable
Enable music menulistDisable
Value Y 16 bitunsignedInt 0…655350
Number feedback alarmunsignedInt 0…50
Time out to send messages after bus ontime400
D) Remote humidity probeslistDisable
S1) External input 1listDisable
Type command objectlistSeparated
Enable shutters A menulistDisable
Heating type systemlistFancoil
Heating type systemlistRadiators
Enable scenes B menulistDisable
Enable lights A menulistDisable
Activated seasonslistHeating
O) Anticondensation contactlistDisable
F) Outdoor temperature probelistDisable
Time to switch off displaytime60
Enable thermostat menulistEnable
Keypad locklistDisable
B) Integrated humidity probelistDisable
C) Remote temperature probeslistDisable
N) Battery temperature probelistDisable
L) Zone 2 - Temperature probelistDisable
Number Scenes Alist1 Scene
Number Scenes Blist1 Scene
S3) External input 3listDisable
A) Integrated temperature probelistEnable
E) Antistratification temperature probelistDisable
Number Shutters Alist1 Shutter
Enable auxiliary heatinglistDisable
Display icons colorlistWhite
Number Shutters Blist1 Shutter
Number feedbacks LED leftunsignedInt 0…50
H) Flow temperature probelistDisable
M) Zone 2 - Humidity probelistDisable
Enable lights B menulistDisable
Enable shutters B menulistDisable
R) Card holder contactlistDisable
Language menuslistEnglish
Number Lights Alist1 Light
Number feedbacks LED rightunsignedInt 0…50
VentilationEnlistDisable
RemSensorEnlistEnable
Enable local input pagelistDisable
Enable Thresholds input 1 pagelistDisable
Enable Thresholds input 2 pagelistDisable
Enable Thresholds input 3 pagelistDisable
EnWindowFunctionlistDisable
EnPresenceFunctionlistDisable
InputAntistratEnlistDisable
EnAntistratificationFunctionlistDisable
InputWindowEnlistDisable
InputPresenceEnlistDisable
InputFloorEnlistDisable
EnFloorFunctionlistDisable
EnTempFunctionlistEnable
InputTempEnlistDisable
EnCombinedFunctionlistDisable
Enable crono managementlistEnable
Crono prioritylistPriority 0
Enable remote managementlistEnable
Remote control prioritylistPriority 0
Enable local managementlistEnable
Local input modelistSetpoint + HVAC
Local control prioritylistPriority 0
Temperature setpoint rangelistFree
Humidity setpoint rangelistDisabled
HVAC local selectionlistComfort, Setpoint, Economy, Protection
Forced HVAC releaselistManual Action
Displayed temperature unitlistCelsius
Setpoint cyclic sending intervallistNone
Time out analog sensorstime300
Time out digital sensorstime300
Filter widthlistMedium
Sensor weightlist100%
Probe temperature correctionfloat -5…50
Cyclic sending intervallistNone
Min delta for sendingfloat 0…50.5
Threshold levelfloat 0…507
Threshold levelfloat 0…5045
Threshold hysteresislist0,4 °C
Thresholds cyclic sending intervallistNone
Dimension humidity objectlistOne byte DataType
Min delta for sendingfloat 0…102
Threshold levelunsignedInt 0…10065
Threshold levelunsignedInt 0…10085
Threshold hysteresislist3,00%
Number probeslistOne sensor
Weight sensor 1list100%
Weight sensor 2list100%
Weight sensor 3list100%
Weight sensor 4list100%
Probe 1 Object type dimensionlistOne byte DataType
Probe 2 Object type dimensionlistOne byte DataType
Enable passive anticondensationlistDisable
Hysteresislist0,5 °C
Project fixed flow templist14,0 °C
Enable badge detectionlistDisable
HVAC on badge insertionlistComfort
Delay to activatetime0
HVAC on badge unplugginglistStandby
Delay to deactivatetime0
Input typelistDigital input
Contact typelistOpen window contact
Debouncetime400
Contact modelistNC (Normally close)
Probe typelistHeat recuperator temperature probe
Filter widthlistLow
Value correctionfloat -5…50
Min delta for sendingfloat 0…50
Threshold levelfloat -20…507
Threshold levelfloat -20…5045
Hysteresislist0,2 °C
Threshold 1 levelfloat -20…507
Threshold 2 levelfloat -20…5045
Actual season cyclic sending intervallistNone
Season change modelistFrom bus
Comfort HVAC levelfloat 10…5023
Standby HVAC levelfloat 10…5026
Economy HVAC levelfloat 10…5028
Protection HVAC levelfloat 30…5036
Type of controllistTwo point hysteresis
Hysteresis positionlistAbove
Two points hysteresis widthlist0,2 °C
Proportional bandunsignedInt 5…1005
Integration time [min]unsignedInt 0…2550
Minimum value of controlunsignedInt 0…3015
Maximum value of controlunsignedInt 70…10085
PWM cycle timetime15
Integration timeunsignedInt 0…2550
Min delta for sendingunsignedInt 0…10010
Setpoint deviationlist0,6 °C
Disable auxiliary cooling from buslistNo
Hysteresislist0,3 °C
Comfort HVAC levelfloat 10…5021
Standby HVAC levelfloat 10…5018
Economy HVAC levelfloat 10…5016
Protection HVAC levelfloat 2…107
Hysteresis positionlistUnder
Two points hysteresis widthlist0,3 °C
Integration time [min]unsignedInt 0…255144
Proportional bandunsignedInt 5…10050
Integration timeunsignedInt 0…255144
Auxiliary command object typelistSeparated
Disable auxiliary heating from buslistNo
IntegrationlistNo
Temp. difference for integrationlist+1,5 °C
Integration hysteresislist0,5 °C
Subordinated to temperature controllistYes
Delay to starttime300
Hysteresislist0,80%
Disable function from buslistNo
Lock message valuelistMessage 0
SetpointunsignedInt 20…8055
SetpointunsignedInt 20…8035
Enable antistratificationlistDisable
Delta temperature antistratificationlist2,00 [°C/m]
Enable windows detectionlistDisable
Wait to activate protectiontime60
Enable presence detectionlistDisable
Presence actionlistComfort extend
Reduction modelistComfort to standby
Delaytime60
Enable floor temp limitationlistDisable
Temperature limitfloat 20…4029
Type of controllistOne speed
Proportional bandunsignedInt 5…10030
Min delta for sendingunsignedInt 2…4010
Speed hysteresislist0,3 °C
Level speed 1unsignedInt 0…25510
Level speed 2unsignedInt 0…25520
Level speed 3unsignedInt 0…25530
Fan start delaylist0 s
Fan stop delaylist0 s
Manual functionalitylistTemperature independent
Disable ventilation from buslistNo
Minimum value to start ventilationunsignedInt 28…4035
Warm startlistOff
Enable dewpointlistDisable
Enable perceived temperaturelistDisable
Function locklistDisable
Number short actionslistNo action
Action 1listSwitching
Switch object valuelistOff
Move object valuelistUp
Number scene valuelist1
ValueunsignedInt 0…2550
Percentage valueunsignedInt 0…2550
HVAC object valuelistAutomatic
Action 2listSwitching
Action 3listSwitching
Number long actionslistNo action
Long pressure timelist0,5 s
Action 1 (long press)listSwitching
Action 2 (long press)listSwitching
Action 3 (long press)listSwitching
Icon selectionlistGeneric
Text labeltext
Status group objectlistDisable
FunctionlistSwitch
Icon selectionlistGeneric light
Step widthlistDisabled
Long press time detectionlist0,5 s
Icon selectionlistLight
Status feedback objectlistDisable
Long press timelist0,5 s
Short press Up modelistDisable
Release mode after long press UplistDisable
Long press Up modelistDisable
Short press Down modelistDisable
Release mode after long press DownlistDisable
Long press Down modelistDisable
Icon selectionlistShutter
Active seasonlistDisabled
LoadedParametersunsignedInt 0…255170
EnHumFunctionlistDisable
Six ways valve controllistDisable
Invert tubes connectionslistDisable
Menu level structurelistSingle level
EnPAnticondFunctionlistDisable
InputAnticondEnlistDisable
Fixed flow valuelistDisable
Measured flow temperaturelistDisable
Time to send alarmlist30 s
Enable advanced menulistEnable
Info in base menulistSetpoint & Measured (T & RH)
Number sourceslist1 Source
InputWaterTempEnlistDisable
EnWarmStartFunclistDisable
A_TempProbe_ThrEnlistDisable
TempProbeB_ThrEnlistDisable
Enable radiant tipologylistDisable
Enable anticondensation functionlistDisable
Feedback typelistFeedback 0-100
Regulation ramp timelist2 s
Volume feedback typelistFeedback 0-255
Icon selectionlistAmplifier 1
Source numberunsignedInt 0…2551
Source numberunsignedInt 0…2552
Source numberunsignedInt 0…2553
Source numberunsignedInt 0…2555
Source numberunsignedInt 0…2554
Regulation ramp timelist12 s
Source numberunsignedInt 0…2556
Track selection typelistOne bit control
Volume control typelistOne bit control (Up/Down)
Number contactslistOne contact
P) Window contactslistDisable
Q) Presence contactslistDisable
EnBadgeFunctionlistDisable
InputBadgeEnlistDisable
Min delta for sendingfloat 0…100
Plate cleaninglistDisable
Forced HVAClistProtection
Zone2EnablelistDisable
Text label zone 1 (main)text
Text label zone 2text
ShutLongA1listDisable
NumProbeunsignedInt 0…1001
NumHProbeunsignedInt 0…1000
Local input modelistSetpoint
HardwareChecklistHardwareType

Version history

ApplicationApp noFingerprintFirst seenSizeFile
Ave. Room Controller S44 0.2 latest$000553172026-11-25371 KBDownload

About this file

This is the official ETS product database for the Ave S.p.A. 442KNXMF-VO Room Controller S44 (442KNXMF-VO), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.

More from Ave S.p.A.

All Ave S.p.A. products