| Objects | list | invisible |
| EE_CkLimit | list | $FD |
| $101 | unsignedInt 0…255 | 2 |
| $102 | unsignedInt 0…255 | 66 |
| $103 | unsignedInt 0…255 | 0 |
| Function channel 1 | list | binary input |
| Channel 1:
Output signal flashing? | list | NO |
| Flashing frequency | list | slow (approx. 1 Hz) |
| Flashing frequency | list | NO |
| Function channel 2 | list | binary input |
| Channel 2:
Output signal flashing? | list | NO |
| Function channel 3 | list | binary input |
| Function channel 4 | list | binary input |
| Delay on return of bus voltage
Base | list | 1 s |
| Delay on return of bus voltage
Factor (3...127) | unsignedInt 3…127 | 17 |
| Debouncing time for binary inputs
Factor (10...255) * 0.5 ms | unsignedInt 10…255 | 60 |
| Telegram rate limitation | list | disabled |
| Telegrams per 17 s | list | 30 |
| Function input 1 | list | switching |
| Funktion_Schaltausgang | list | output |
| keine_Funktion | list | no function |
| Operation | list | n.o. contact |
| Response to bus voltage return | list | none |
| Switching | list | no function |
| Command on rising edge
Switching object 1.1 | list | ON |
| Command on falling edge
Switching object 1.1 | list | OFF |
| Command on rising edge
Switching object 1.2 | list | no reaction |
| Command on falling edge
Switching object 1.2 | list | no reaction |
| Response to bus voltage return | list | no reaction |
| Cyclical transmission? | list | no cyclical transmission |
| Time base for cyclical transmission
Switching object 1.1 | list | 1 s |
| Time base for cyclical transmission
Switching object 1.2 | list | no cyclical transmission via switching object X.2 |
| Time factor for cyclical transmission
Switching object 1.1 and 1.2 (3...127) | unsignedInt 3…127 | 60 |
| Dimming | list | no function |
| Response to bus voltage return | list | open contact |
| Operation | list | double-button operation: brighter (ON) |
| Time between switching and dimming
Base | list | 130 ms |
| Time between switching and dimming
Factor (4...127) | unsignedInt 4…127 | 4 |
| Verh_Bspwdk_$1D7 | list | YES |
| Verh_Bspwdk_$1D8 | list | YES |
| dummy | list | NO |
| Increase brightness by | list | 100 % |
| Reduce brightness by | list | 100 % |
| Transmit stop telegram? | list | YES |
| Repeat telegram? | list | NO |
| Time between two telegrams
Base | list | 130 ms |
| Time between two telegrams
Factor (3...127) | unsignedInt 3…127 | 10 |
| Shutter/blind | list | no function |
| Time function | list | none |
| Command on rising edge | list | DOWN |
| Turn-on delay factor (0...127) | unsignedInt 0…127 | 0 |
| Turn-off delay factor (0...127) | unsignedInt 0…127 | 10 |
| Turn-off delay base | list | 130 ms |
| Turn-on and turn-off delay base | list | 130 ms |
| Turn-on delay base | list | 130 ms |
| Operating concept | list | step - move - step |
| Timer function | list | OFF |
| Reaction to OFF telegram | list | switch off |
| Time between STEP and MOVE operation
Base | list | 130 ms |
| Time between STEP and MOVE operation
Factor (4...127) | unsignedInt 4…127 | 4 |
| Slat adjustment time
Base | list | 130 ms |
| Slat adjustment time
Factor (3...127) | unsignedInt 3…127 | 20 |
| Function as | list | dimming value transmitter |
| Feedback | list | none |
| LS_ohne_Spfnkt | list | light-scene extension without storage function |
| Dimming value transmitter | list | dimming value transmitter |
| LS_mit_Spfnkt | list | light-scene extension without storage function |
| Tempareture value transmitter | list | tempareture value transmitter |
| Brightness value transmitter | list | brightness value transmitter |
| Transmit value | list | on rising edge (push button as n.o. contact) |
| Transmit light-scene number | list | on rising edge (push button as n.o. contact) |
| Value on rising edge
(0...255) | unsignedInt 0…255 | 0 |
| Light-scene on rising edge
(1...64) | unsignedInt 1…64 | 1 |
| Value on rising edge | list | 20 °C |
| Value on rising edge | list | 200 Lux |
| Light-scene on falling edge
(1...64) | unsignedInt 1…64 | 1 |
| Value on falling edge
(0...255) | unsignedInt 0…255 | 0 |
| Value on falling edge | list | 18 °C |
| Value on falling edge | list | 0 Lux |
| Transmit value on rising edge? | list | NO |
| Transmit value on falling edge? | list | YES |
| Speicherfnkt_Freig | list | NO |
| Value change by long press? | list | NO |
| Time between two telegrams
Factor (3...127) | unsignedInt 3…127 | 60 |
| Step width (1...10) | unsignedInt 1…10 | 10 |
| Step width | list | 50 Lux |
| Step width | list | 1 °C |
| Storage function only? | list | NO |
| Timer2_130msfest | list | 130 ms |
| Time of a long press for storage
Base | list | 130 ms |
| Feedback | list | inverted |
| Time of a long press for storage
Factor (4...127) | unsignedInt 4…127 | 4 |
| Time of a long press for storage
Factor (0...127) | unsignedInt 0…127 | 0 |
| Time of a long press for storage
Factor (9...127) | unsignedInt 9…127 | 10 |
| Time of a long press for storage
Factor (13...127) | unsignedInt 13…127 | 19 |
| Time of a long press for storage
Factor (24...127) | unsignedInt 24…127 | 38 |
| Additional function | list | none |
| Objekt_3_Zuordnung | list | 1 |
| Funktion_3_Objekt | list | logic-operation object |
| Pulse counter | list | no function |
| Count pulse at | list | input 1 |
| Sync signal at | list | input 3 |
| Count pulses at the input | list | on rising edge |
| Transmit interval time for count
Base | list | 130 ms |
| Transmit interval time for count
Factor (3...127) | unsignedInt 3…127 | 60 |
| Reset count and interval time
by sync signal | list | on rising edge |
| Telegram on reception of a
sync signal | list | rising edge = ON, falling edge = --- |
| S+G1851witching event counter | list | no function |
| Maximun count
(1...65535) | unsignedInt 1…65535 | 65535 |
| Command on maximum count | list | ON |
| Step width counter status output
(1...255) | unsignedInt 1…255 | 255 |
| Disabling function | list | disabled |
| Funktion_gesp | list | no reaction |
| Disabling object polarity | list | disable = 1 (enable = 0) |
| Response at the beginning of disabling
Switching objects 1.1 and 1.2 | list | no reaction |
| Response at the beginning of disabling | list | no reaction |
| Response at the end of disabling | list | no reaction |
| Response at the end of disabling
Switching objects 1.1 and 1.2 | list | no reaction |
| Response at the end of disabling | list | YES |
| Response at the end of disabling | list | NO |
| Logic operation | list | AND |
| Disabling object polarity | list | enabled = 0, disabled = 1 |
| Function at the beginning of disabling
(keep to the parameter "Mode") | list | switch off |
| Function at the end of disabling
(keep to the parameter "Mode") | list | no change |
| Function input 2 | list | switching |
| keine_Funktion | list | pulse counter |
| Switching | list | pulse counter |
| Command on rising edge
Switching object 2.1 | list | ON |
| Command on falling edge
Switching object 2.1 | list | OFF |
| Command on rising edge
Switching object 2.2 | list | no reaction |
| Command on falling edge
Switching object 2.2 | list | no reaction |
| Time base for cyclical transmission
Switching object 2.1 | list | 1 s |
| Time base for cyclical transmission
Switching object 2.2 | list | no cyclical transmission via switching object X.2 |
| Time factor for cyclical transmission
Switching object 2.1 and 2.2 (3...127) | unsignedInt 3…127 | 3 |
| Dimming | list | pulse counter |
| Time between switching and dimming
Base | list | 520 ms |
| Verh_Bspwdk_$1DB | list | NO |
| Verh_Bspwdk_$1DC | list | NO |
| Repeat telegram? | list | YES |
| Time between two telegrams
Factor (3...127) | unsignedInt 3…127 | 3 |
| Shutter/blind | list | pulse counter |
| Time between STEP and MOVE operation
Base | list | 2.1 s |
| Time between STEP and MOVE operation
Factor (4...127) | unsignedInt 4…127 | 5 |
| Value on rising edge
(0...255) | unsignedInt 0…255 | 100 |
| Value on falling edge
(0...255) | unsignedInt 0…255 | 100 |
| Transmit value on rising edge? | list | YES |
| Speicherfnkt_Freig | list | YES |
| Time between two telegrams
Base | list | 520 ms |
| Time of a long press for storage
Base | list | 520 ms |
| Time of a long press for storage
Factor (4...127) | unsignedInt 4…127 | 5 |
| Objekt_3_Zuordnung | list | 2 |
| Pulse counter | list | pulse counter |
| Count pulse at | list | input 2 |
| Sync signal at | list | input 4 |
| Transmit interval time for count
Base | list | 2.1 s |
| Transmit interval time for count
Factor (3...127) | unsignedInt 3…127 | 3 |
| Switching event counter | list | pulse counter |
| Response at the beginning of disabling
Switching objects 2.1 and 3.2 | list | no reaction |
| Response at the end of disabling
Switching objects 2.1 and 2.2 | list | no reaction |
| Function input 3 | list | switching |
| keine_Funktion | list | sync input |
| Switching | list | sync input |
| Command on rising edge
Switching object 3.1 | list | ON |
| Command on falling edge
Switching object 3.1 | list | OFF |
| Command on rising edge
Switching object 3.2 | list | no reaction |
| Command on falling edge
Switching object 3.2 | list | no reaction |
| Time base for cyclical transmission
Switching object 3.1 | list | 1 s |
| Time base for cyclical transmission
Switching object 3.2 | list | no cyclical transmission via switching object X.2 |
| Time factor for cyclical transmission
Switching object 3.1 and 3.2 (3...127) | unsignedInt 3…127 | 3 |
| Dimming | list | sync input |
| Verh_Bspwdk_$1DF | list | YES |
| Verh_Bspwdk_$1E0 | list | YES |
| Shutter/blind | list | sync input |
| Command on rising edge | list | UP |
| Transmit value on falling edge? | list | NO |
| Function | list | sync input |
| Response at the beginning of disabling
Switching objects 3.1 and 3.2 | list | no reaction |
| Response at the end of disabling
Switching objects 3.1 and 3.2 | list | no reaction |
| Function input 4 | list | switching |
| Command on rising edge
Switching object 4.1 | list | ON |
| Command on falling edge
Switching object 4.1 | list | OFF |
| Command on rising edge
Switching object 4.2 | list | no reaction |
| Command on falling edge
Switching object 4.2 | list | no reaction |
| Time base for cyclical transmission
Switching object 4.1 | list | 1 s |
| Time base for cyclical transmission
Switching object 4.2 | list | no cyclical transmission via switching object X.2 |
| Time factor for cyclical transmission
Switching object 4.1 and 4.2 (3...127) | unsignedInt 3…127 | 60 |
| Verh_Bspwdk_$1E3 | list | YES |
| Verh_Bspwdk_$1E4 | list | YES |
| Response at the beginning of disabling
Switching objects 4.1 and 4.2 | list | no reaction |
| Response at the end of disabling
Switching objects 4.1 and 4.2 | list | no reaction |
| Function input 5 | list | no function |
| keine_Funktion | list | shutter/blind |
| Switching | list | shutter/blind |
| Command on rising edge
Switching object 5.1 | list | ON |
| Command on falling edge
Switching object 5.1 | list | OFF |
| Command on rising edge
Switching object 5.2 | list | no reaction |
| Command on falling edge
Switching object 5.2 | list | no reaction |
| Time base for cyclical transmission
Switching object 5.1 | list | 1 s |
| Time base for cyclical transmission
Switching object 5.2 | list | no cyclical transmission via switching object X.2 |
| Time factor for cyclical transmission
Switching object 5.1 and 5.2 (3...127) | unsignedInt 3…127 | 60 |
| Dimming | list | shutter/blind |
| Verh_Bspwdk_$1E7 | list | NO |
| Verh_Bspwdk_$1E8 | list | NO |
| Shutter/blind | list | shutter/blind |
| Response at the beginning of disabling
Switching objects 5.1 and 5.2 | list | no reaction |
| Response at the end of disabling
Switching objects 5.1 and 5.2 | list | no reaction |
| Function input 6 | list | no function |
| Command on rising edge
Switching object 6.1 | list | ON |
| Command on falling edge
Switching object 6.1 | list | OFF |
| Command on rising edge
Switching object 6.2 | list | no reaction |
| Command on falling edge
Switching object 6.2 | list | no reaction |
| Time base for cyclical transmission
Switching object 6.1 | list | 1 s |
| Time base for cyclical transmission
Switching object 6.2 | list | no cyclical transmission via switching object X.2 |
| Time factor for cyclical transmission
Switching object 6.1 and 6.2 (3...127) | unsignedInt 3…127 | 60 |
| Verh_Bspwdk_$1EB | list | NO |
| Verh_Bspwdk_$1EC | list | NO |
| Response at the beginning of disabling
Switching objects 6.1 and 6.2 | list | no reaction |
| Response at the end of disabling
Switching objects 6.1 and 6.2 | list | no reaction |
| Function input 7 | list | no function |
| Command on rising edge
Switching object 7.1 | list | ON |
| Command on falling edge
Switching object 7.1 | list | OFF |
| Command on rising edge
Switching object 7.2 | list | no reaction |
| Command on falling edge
Switching object 7.2 | list | OFF |
| Time base for cyclical transmission
Switching object 7.1 | list | 1 s |
| Time base for cyclical transmission
Switching object 7.2 | list | no cyclical transmission via switching object X.2 |
| Time factor for cyclical transmission
Switching object 7.1 and 7.2 (3...127) | unsignedInt 3…127 | 60 |
| Verh_Bspwdk_$1EF | list | NO |
| Verh_Bspwdk_$1F0 | list | NO |
| Response at the beginning of disabling
Switching objects 7.1 and 7.2 | list | no reaction |
| Response at the end of disabling
Switching objects 7.1 and 7.2 | list | no reaction |
| Function input 8 | list | no function |
| Command on rising edge
Switching object 8.1 | list | ON |
| Command on falling edge
Switching object 8.1 | list | OFF |
| Command on rising edge
Switching object 8.2 | list | no reaction |
| Command on falling edge
Switching object 8.2 | list | OFF |
| Time base for cyclical transmission
Switching object 8.1 | list | 1 s |
| Time base for cyclical transmission
Switching object 8.2 | list | no cyclical transmission via switching object X.2 |
| Time factor for cyclical transmission
Switching object 8.1 and 8.2 (3...127) | unsignedInt 3…127 | 3 |
| Verh_Bspwdk_$1F3 | list | NO |
| Verh_Bspwdk_$1F4 | list | NO |
| Response at the beginning of disabling
Switching objects 8.1 and 8.2 | list | no reaction |
| Response at the end of disabling
Switching objects 8.1 and 8.2 | list | no reaction |