ABB SpA-SACE Division 2CSY244280R1202 RT/U 1.1.ZW Thermostat

RT/U 1.1.ZW Thermostat 2CSY244280R1202

ABB SpA-SACE Division · Order number 2CSY244280R1202 · Heating, air conditioning, ventilation › Thermostat with display

Download .knxprod Thermostat/2.0 2.12 · 151 KB

Product

ManufacturerABB SpA-SACE Division
Product nameRT/U 1.1.ZW Thermostat
Order number2CSY244280R1202
HardwareTermostato solo TP
MediumTwisted Pair
Bus current (mA)12
Rail mountedNo
RegistrationCertified · 2021-06-11
Languagesen-US, it-IT, de-DE, es-ES
Catalog entryM-000E_H-E0002D-1_HP-000D-2C-5AC1_CI-2CSY244280R1202-1
Fingerprint5AC1
SHA-25687554d5bbeff2581873d4830a37b616bf1be4591304f6aafc76d2ba779df36e5
First seen2026-11-25
MarketsFrance, Germany, Greece, Italy, Saudi Arabia, Spain

Application program: Thermostat/2.0 2.12

Application number$000D
Version2.12
Mask versionMV-0701 (7.1)
KNX Data SecureNo
Parameters118
Group objects47
Group objects (47)
NoNameFunctionSizeDPTFlags
0GeneralIn operation1 Bit1.1 switchCT
1Operating modeFrost/heat protection1 Bit1.1 switchCRW
2Operating modeNight mode1 Bit1.1 switchCRW
3Operating modeComfort/Stand by mode1 Bit1.1 switchCRWT
8Operating modeOperating mode switching1 ByteCRWT
9ControlTemper. sending2 Bytes9.1 temperature (°C)CRT
10ControlHeating status1 Bit1.3 enableCRWTU
10ControlHeating status1 Bit1.3 enableCRWT
12ControlCooling status1 Bit1.3 enableCRWTU
12ControlCooling status1 Bit1.3 enableCRT
13ControlHeat. contr.value (switching)1 Bit1.1 switchCRT
13ControlHeat. contr.value (count)1 Byte5.1 percentage (0..100%)CRT
13ControlHeat./Cool. contr.value (count1 Byte5.1 percentage (0..100%)CRT
13ControlHeat./Cool. contr.value (switc1 Bit1.1 switchCRT
14ControlCool. contr.value (count)1 Byte5.1 percentage (0..100%)CRT
14ControlCool. contr.value (switching)1 Bit1.1 switchCRT
15ControlCurrent setpoint - Cool.2 Bytes9.1 temperature (°C)CRWT
16ControlCurrent setpoint - Heat.2 Bytes9.1 temperature (°C)CRWT
17ControlCommunication obj. for reset1 Bit1.1 switchCW
18ControlBase setpoint2 Bytes9.1 temperature (°C)CRW
18ControlBase setpoint2 Bytes9.1 temperature (°C)CWT
19GeneralDevice ON/OFF1 Bit1.1 switchCRWT
20Fan auto/manManual On/Off1 Bit1.1 switchCRWT
20Fan auto/manAutomatic On/Off1 Bit1.1 switchCRWT
21Manual fanFan 1 byte manual control1 Byte5.10 counter pulses (0..255)CRWT
21Manual fanFan 1 byte manual control1 Byte5.1 percentage (0..100%)CRWT
23Manual fanFan stage manual control 11 Bit1.1 switchCRWT
24Manual fanFan stage manual control 21 Bit1.1 switchCRWT
25Manual fanFan stage manual control 31 Bit1.1 switchCRWT
26Operating modeSwitching heating/cooling1 Bit1.1 switchCRWT
26Operating modeSwitching heating/cooling1 Bit1.1 switchCRT
27ControlComfort setpoint - Heat.2 Bytes9.1 temperature (°C)CW
28ControlSetpoint Stand By - Heat.2 Bytes9.1 temperature (°C)CW
29ControlNight setpoint - Heat.2 Bytes9.1 temperature (°C)CW
30ControlSetpoint frost protection2 Bytes9.1 temperature (°C)CW
31ControlComfort setpoint - Cool.2 Bytes9.1 temperature (°C)CW
32ControlSetpoint Standby - Cooling2 Bytes9.1 temperature (°C)CW
33ControlNight setpoint - Cool.2 Bytes9.1 temperature (°C)CW
34ControlHeat setpoint - Cooling2 Bytes9.1 temperature (°C)CW
35ControlReceiving actuator status1 Bit1.1 switchCW
36Fan automaticFan autom. Level 11 Bit1.3 enableCRT
37Fan automaticFan autom. Level 21 Bit1.3 enableCRT
38Fan automaticFan autom. Level 31 Bit1.3 enableCRT
39ControlAdd. heat. contr.value1 Bit1.1 switchCRT
39ControlAdd. heat. contr.value1 Byte5.1 percentage (0..100%)CRT
40ControlAdd. cool. contr.value1 Bit1.1 switchCRT
40ControlAdd. cool. contr.value1 Byte5.1 percentage (0..100%)CRT
Parameters (74)
ParameterTypeDefault
GenerallistComfort/Stand by/OFF
"In operation" telegram cyclic sendinglistCyclic sending value 0
Transmission period [0......65535] secondsunsignedInt 0…655350
Temperature unit of measurementlistCelsius
Display heat/cond is activelistOnly if operating mode is active
Operating mode switchoverlist1 bit (3 x DPT_Switch)
1 = Comfort, 2 = Night, 3 = Stand by 4 = Frost/heat protectionlist<----------------------------------------NOTE
Switching Comfort/Stand by via buttonlistComfort/Stand by
Operation mode after resetlistComfort
Offset for room temp. \measured ((-30.....30) * 0.1 °C)list0
Minimum temperature variation so that it is sent over the buslistInactive
Period of room temperature cyclic sending (0 - not active) minunsignedInt 0…600
Thermostat functionslistHeating
Switchover between heating and coolinglistAutomatic
Add. heating controllistno
Add. cooling controllistno
Number of output chann.list1 channel for heating/cooling
Status send heat requirementlistno
Cycle time control value sending 0...60 min. (0 - inactive)unsignedInt 0…600
Control modelist2points
Hystereslist1.0°C
Minimum control value variation so that it is sent over the busunsignedInt 0…155
Minimum value variation so that it is sent over the busunsignedInt 0…155
Minimum variation of the value sent over the busunsignedInt 0…155
Invert heatinglistno
Status send cool requirementlistno
Invert coolinglistno
Control typelist1 bit control
Invert control valuelistno
Additional control value interval (0…127) x 0.1°CunsignedInt 0…12730
Cyclic sending of setpoint 0...60 minutes (0 – inactive, min)unsignedInt 0…600
Select base setpointlistDependent setpoints
Reference base setpointlistHeating
Manual setpoint adjustment at reset of change from night/to nightlistno
Manual setpoint adjustmentlistyes
Maximum manual setpoint increaselist5°C
Maximum manual setpoint reductionlist5°C
Setpoints reset trough comunication objectlistno
When receiving a new base setpointlistRetain manual setpoint adjust.
Setpoint in Comfort modelist21.0 °C
Setpoint in Comfort modelist23.0 °C
Heating setpoint comfort modelist21.0 °C
Heating setpoint comfort modelist21.0 °C
Heating setpoint standby modelist19.0 °C
Cooling setpoint decrease Stand by modelist2.0°C
Cooling setpoint decrease Stand by modelist19.0 °C
Cooling setpoint increase Stand by modelist2.0°C
Heating setpoint night modelist15.0 °C
Heating setpoint in Stand by modelist25.0 °C
Cooling setpoint decrease night modelist4.0°C
Cooling setpoint decrease night modelist15.0 °C
Cooling setpoint increase night modelist4.0°C
Heating setpoint night modelist27.0 °C
Cooling setpoint comfortmodelist23.0 °C
Setpoint \frost protectionlist7°C
Setpoint \heat protectionlistCheck disabled
Cooling setpoint standby modelist25.0 °C
Cooling setpoint night modelist27.0 °C
Minimum distance between heating and cooling setpointlist2.0°C
Number of fan levelslist3 Levels
The manual mode is indicated to actuator throughlistCommunication object "On/Off Automatic"
Object manual fan stage send has the following codelist1 1-byte CO with values from 0 to 100%
Send cycle time of actuator in sec [0...65535] (0-disab)unsignedInt 0…655350
FanCoil stage after resetlistAutomatic
Step limit in ight modelistNo limit
Cycle time PWM control value (min)unsignedInt 0…6010
Return to automatic mode from manual adjustment (0 - not active,min)unsignedInt 0…600
Minimum percentage for termovalve activationunsignedInt 0…3010
Return to auto mode from FanCoil OFFlistyes
Maximum percentage for termovalve deactivationunsignedInt 70…10090
Stage1 threshold (%)unsignedInt 0…10010
PWM cycle is 100% up to \control valueunsignedInt 70…10090
Stage2 threshold (%)unsignedInt 0…10040
Stage3 threshold (%)unsignedInt 0…10070

Version history

ApplicationApp noFingerprintFirst seenSizeFile
Thermostat/2.0 2.12 latest$000D5AC12026-11-25151 KBDownload

About this file

This is the official ETS product database for the ABB SpA-SACE Division RT/U 1.1.ZW Thermostat (2CSY244280R1202), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.