HS/S4.2.1 Outside Light Sensor Interface,MDRC 2CDG 120 044 R0011
ABB AG - STOTZ-KONTAKT · Order number 2CDG 120 044 R0011 · Lighting Control › Light Level Sensors
Brightness Sensor 4C/1.0a
Download .knxprod Brightness Sensor 4C/1.0a 1.0 · 307 KB
Product
| Manufacturer | ABB AG - STOTZ-KONTAKT |
|---|---|
| Product name | HS/S4.2.1 Outside Light Sensor Interface,MDRC |
| Order number | 2CDG 120 044 R0011 |
| Hardware | LUNA 134 |
| Medium | Twisted Pair |
| Bus current (mA) | 65535 |
| Rail mounted | Yes |
| Width (mm) | -1 |
| Registration | Registered |
| Languages | en-US, de-DE, es-ES, fr-FR, it-IT, nl-NL |
| Catalog entry | M-0002_H-1349200-1-O0048_HP-134A-10-2A22-O0048_CI-2CDG.20120.20044.20R0011-1 |
| Fingerprint | 2A22 |
| SHA-256 | 410e6b2228d5ad702da04c4d0ab8c565c288edd2b0801f7048d42d5c92bf02c8 |
| First seen | 2026-11-25 |
| Markets | 59 markets |
Application program: Brightness Sensor 4C/1.0a 1.0
| Application number | $134A |
|---|---|
| Version | 1.0 |
| Mask version | MV-0701 (7.1) |
| KNX Data Secure | No |
| Parameters | 1217 |
| Group objects | 328 |
Group objects (328)
| No | Name | Function | Size | DPT | Flags |
|---|---|---|---|---|---|
| 0 | Brightness value sensor 1 | Physical value | 2 Bytes | CRT | |
| 1 | Brightness value sensor 2 | Physical value | 2 Bytes | CRT | |
| 2 | Brightness value sensor 3 | Physical value | 2 Bytes | CRT | |
| 3 | Maximum brightness value | Physical value | 2 Bytes | CRT | |
| 4 | Temperature value | Physical value | 2 Bytes | CRT | |
| 5 | Wind speed | Physical value | 2 Bytes | CRT | |
| 6 | Rain sensor | Rain / no rain | 1 Bit | CRT | |
| 7 | Reserve | 3 Bytes | |||
| 8 | Reserve | 2 Bytes | |||
| 9 | Reserve | 2 Bytes | |||
| 10 | Reserve | 2 Bytes | |||
| 11 | Reserve | 2 Bytes | |||
| 12 | Reserve | 2 Bytes | |||
| 13 | Reserve | 2 Bytes | |||
| 14 | Wind sensor status | 0=OK, 1=Defective | 1 Bit | CRTU | |
| 15 | Temperature sensor status | 0=OK, 1=Defective | 1 Bit | CRTU | |
| 16 | Rain sensor status | 0=OK, 1=Defective | 1 Bit | CRTU | |
| 17 | Brightness sensors status | 0=OK, 1=Min. 1 sensor defect. | 1 Bit | CRTU | |
| 18 | Reserve | 2 Bytes | CRW | ||
| 19 | Reserve | 2 Bytes | CRW | ||
| 20 | C1.1 switching channel | priority | 2 Bit | CRT | |
| 20 | C1.1 switching channel | Valuator | 1 Byte | CRT | |
| 20 | C1.1 switching channel | Switching | 1 Bit | CRT | |
| 21 | C1.2 switching channel | Valuator | 1 Byte | CRT | |
| 21 | C1.2 switching channel | priority | 2 Bit | CRT | |
| 21 | C1.2 switching channel | Switching | 1 Bit | CRT | |
| 22 | C1 lock | lock = 0 | 1 Bit | CRW | |
| 22 | C1 lock | lock = 1 | 1 Bit | CRW | |
| 23 | C1 brightness threshold | specify/request | 2 Bytes | CRWT | |
| 23 | C1 brightness threshold | Request | 2 Bytes | CRT | |
| 24 | Reserve | 1 Byte | CRWTU | ||
| 24 | C2.1 switching channel | Switching | 1 Bit | CRT | |
| 24 | C2.1 switching channel | Valuator | 1 Byte | CRT | |
| 24 | C2.1 switching channel | priority | 2 Bit | CRT | |
| 25 | Reserve | 1 Bit | CRWTU | ||
| 25 | C2.2 switching channel | Switching | 1 Bit | CRT | |
| 25 | C2.2 switching channel | Valuator | 1 Byte | CRT | |
| 25 | C2.2 switching channel | priority | 2 Bit | CRT | |
| 26 | Reserve | 2 Bytes | CRWTU | ||
| 26 | C2 lock | lock = 0 | 1 Bit | CRW | |
| 26 | C2 lock | lock = 1 | 1 Bit | CRW | |
| 27 | Reserve | 1 Byte | CRWTU | ||
| 27 | C2 brightness threshold | specify/request | 2 Bytes | CRWT | |
| 27 | C2 brightness threshold | Request | 2 Bytes | CRT | |
| 28 | Reserve | 1 Byte | CRWTU | ||
| 28 | C3.1 switching channel | Switching | 1 Bit | CRT | |
| 28 | C3.1 switching channel | Valuator | 1 Byte | CRT | |
| 28 | C3.1 switching channel | priority | 2 Bit | CRT | |
| 29 | Reserve | 1 Bit | CRWTU | ||
| 29 | C3.2 switching channel | Switching | 1 Bit | CRT | |
| 29 | C3.2 switching channel | Valuator | 1 Byte | CRT | |
| 29 | C3.2 switching channel | priority | 2 Bit | CRT | |
| 30 | Reserve | 2 Bytes | CRWTU | ||
| 30 | C3 lock | lock = 0 | 1 Bit | CRW | |
| 30 | C3 lock | lock = 1 | 1 Bit | CRW | |
| 31 | Reserve | 1 Byte | CRWTU | ||
| 31 | C3 brightness threshold | Request | 2 Bytes | CRT | |
| 31 | C3 brightness threshold | specify/request | 2 Bytes | CRWT | |
| 32 | Reserve | 1 Byte | CRWTU | ||
| 32 | C4.1 switching channel | priority | 2 Bit | CRT | |
| 32 | C4.1 switching channel | Valuator | 1 Byte | CRT | |
| 32 | C4.1 switching channel | Switching | 1 Bit | CRT | |
| 33 | Reserve | 1 Bit | CRWTU | ||
| 33 | C4.2 switching channel | priority | 2 Bit | CRT | |
| 33 | C4.2 switching channel | Switching | 1 Bit | CRT | |
| 33 | C4.2 switching channel | Valuator | 1 Byte | CRT | |
| 34 | Reserve | 2 Bytes | CRWTU | ||
| 34 | C4 lock | lock = 1 | 1 Bit | CRW | |
| 34 | C4 lock | lock = 0 | 1 Bit | CRW | |
| 35 | Reserve | 1 Byte | CRWTU | ||
| 35 | C4 brightness threshold | specify/request | 2 Bytes | CRWT | |
| 35 | C4 brightness threshold | Request | 2 Bytes | CRT | |
| 36 | Reserve | 1 Byte | CRWTU | ||
| 36 | C5.1 switching channel | priority | 2 Bit | CRT | |
| 36 | C5.1 switching channel | Valuator | 1 Byte | CRT | |
| 36 | C5.1 switching channel | Switching | 1 Bit | CRT | |
| 37 | Reserve | 1 Bit | CRWTU | ||
| 37 | C5.2 switching channel | Valuator | 1 Byte | CRT | |
| 37 | C5.2 switching channel | priority | 2 Bit | CRT | |
| 37 | C5.2 switching channel | Switching | 1 Bit | CRT | |
| 38 | Reserve | 2 Bytes | CRWTU | ||
| 38 | C5 lock | lock = 0 | 1 Bit | CRW | |
| 38 | C5 lock | lock = 1 | 1 Bit | CRW | |
| 39 | Reserve | 1 Byte | CRWTU | ||
| 39 | C5 brightness threshold | Request | 2 Bytes | CRT | |
| 39 | C5 brightness threshold | specify/request | 2 Bytes | CRWT | |
| 40 | Reserve | 1 Byte | CRWTU | ||
| 40 | C6.1 switching channel | Switching | 1 Bit | CRT | |
| 40 | C6.1 switching channel | priority | 2 Bit | CRT | |
| 40 | C6.1 switching channel | Valuator | 1 Byte | CRT | |
| 41 | Reserve | 1 Bit | CRWTU | ||
| 41 | C6.2 switching channel | Switching | 1 Bit | CRT | |
| 41 | C6.2 switching channel | Valuator | 1 Byte | CRT | |
| 41 | C6.2 switching channel | priority | 2 Bit | CRT | |
| 42 | Reserve | 2 Bytes | CRWTU | ||
| 42 | C6 lock | lock = 1 | 1 Bit | CRW | |
| 42 | C6 lock | lock = 0 | 1 Bit | CRW | |
| 43 | Reserve | 1 Byte | CRWTU | ||
| 43 | C6 brightness threshold | specify/request | 2 Bytes | CRWT | |
| 43 | C6 brightness threshold | Request | 2 Bytes | CRT | |
| 44 | Reserve | 1 Byte | CRWTU | ||
| 44 | C7.1 switching channel | priority | 2 Bit | CRT | |
| 44 | C7.1 switching channel | Valuator | 1 Byte | CRT | |
| 44 | C7.1 switching channel | Switching | 1 Bit | CRT | |
| 45 | Reserve | 1 Bit | CRWTU | ||
| 45 | C7.2 switching channel | Valuator | 1 Byte | CRT | |
| 45 | C7.2 switching channel | priority | 2 Bit | CRT | |
| 45 | C7.2 switching channel | Switching | 1 Bit | CRT | |
| 46 | Reserve | 2 Bytes | CRWTU | ||
| 46 | C7 lock | lock = 0 | 1 Bit | CRW | |
| 46 | C7 lock | lock = 1 | 1 Bit | CRW | |
| 47 | Reserve | 1 Byte | CRWTU | ||
| 47 | C7 brightness threshold | Request | 2 Bytes | CRT | |
| 47 | C7 brightness threshold | specify/request | 2 Bytes | CRWT | |
| 48 | Reserve | 1 Byte | CRWTU | ||
| 48 | C8.1 switching channel | priority | 2 Bit | CRT | |
| 48 | C8.1 switching channel | Valuator | 1 Byte | CRT | |
| 48 | C8.1 switching channel | Switching | 1 Bit | CRT | |
| 49 | Reserve | 1 Bit | CRWTU | ||
| 49 | C8.2 switching channel | Valuator | 1 Byte | CRT | |
| 49 | C8.2 switching channel | priority | 2 Bit | CRT | |
| 49 | C8.2 switching channel | Switching | 1 Bit | CRT | |
| 50 | Reserve | 2 Bytes | CRWTU | ||
| 50 | C8 lock | lock = 0 | 1 Bit | CRW | |
| 50 | C8 lock | lock = 1 | 1 Bit | CRW | |
| 51 | Reserve | 1 Byte | CRWTU | ||
| 51 | C8 brightness threshold | Request | 2 Bytes | CRT | |
| 51 | C8 brightness threshold | specify/request | 2 Bytes | CRWT | |
| 52 | Reserve | 1 Byte | CRWTU | ||
| 52 | C9.1 switching channel | priority | 2 Bit | CRT | |
| 52 | C9.1 switching channel | Valuator | 1 Byte | CRT | |
| 52 | C9.1 switching channel | Switching | 1 Bit | CRT | |
| 53 | Reserve | 1 Bit | CRWTU | ||
| 53 | C9.2 switching channel | Valuator | 1 Byte | CRT | |
| 53 | C9.2 switching channel | priority | 2 Bit | CRT | |
| 53 | C9.2 switching channel | Switching | 1 Bit | CRT | |
| 54 | Reserve | 2 Bytes | CRWTU | ||
| 54 | C9 lock | lock = 0 | 1 Bit | CRW | |
| 54 | C9 lock | lock = 1 | 1 Bit | CRW | |
| 55 | Reserve | 1 Byte | CRWTU | ||
| 55 | C9 brightness threshold | Request | 2 Bytes | CRT | |
| 55 | C9 brightness threshold | specify/request | 2 Bytes | CRWT | |
| 56 | Reserve | 1 Byte | CRWTU | ||
| 56 | C10.1 switching channel | Switching | 1 Bit | CRT | |
| 56 | C10.1 switching channel | priority | 2 Bit | CRT | |
| 56 | C10.1 switching channel | Valuator | 1 Byte | CRT | |
| 57 | Reserve | 1 Bit | CRWTU | ||
| 57 | C10.2 switching channel | Valuator | 1 Byte | CRT | |
| 57 | C10.2 switching channel | priority | 2 Bit | CRT | |
| 57 | C10.2 switching channel | Switching | 1 Bit | CRT | |
| 58 | Reserve | 2 Bytes | CRWTU | ||
| 58 | C10 lock | lock = 0 | 1 Bit | CRW | |
| 58 | C10 lock | lock = 1 | 1 Bit | CRW | |
| 59 | Reserve | 2 Bytes | CRWTU | ||
| 59 | C10 brightness threshold | specify/request | 2 Bytes | CRWT | |
| 59 | C10 brightness threshold | Request | 2 Bytes | CRT | |
| 60 | C11 threshold switch input | EIS 5 | 2 Bytes | CRW | |
| 60 | C11 threshold switch input | 0..65535 | 2 Bytes | CRW | |
| 60 | C11 threshold switch input | 0..255 | 1 Byte | CRW | |
| 60 | C11 threshold switch input | Percent | 1 Byte | CRW | |
| 61 | C11 lock | lock = 1 | 1 Bit | CRW | |
| 61 | C11 lock | lock = 0 | 1 Bit | CRW | |
| 62 | C11.1 threshold switch | Valuator | 1 Byte | CRT | |
| 62 | C11.1 threshold switch | Switching | 1 Bit | CRT | |
| 62 | C11.1 threshold switch | priority | 2 Bit | CRT | |
| 63 | C11.2 threshold switch | Valuator | 1 Byte | CRT | |
| 63 | C11.2 threshold switch | priority | 2 Bit | CRT | |
| 63 | C11.2 threshold switch | Switching | 1 Bit | CRT | |
| 64 | C12 threshold switch input | 0..65535 | 2 Bytes | CRW | |
| 64 | C12 threshold switch input | EIS 5 | 2 Bytes | CRW | |
| 64 | C12 threshold switch input | Percent | 1 Byte | CRW | |
| 64 | C12 threshold switch input | 0..255 | 1 Byte | CRW | |
| 65 | C12 lock | lock = 0 | 1 Bit | CRW | |
| 65 | C12 lock | lock = 1 | 1 Bit | CRW | |
| 66 | C12.1 threshold switch | priority | 2 Bit | CRT | |
| 66 | C12.1 threshold switch | Switching | 1 Bit | CRT | |
| 66 | C12.1 threshold switch | Valuator | 1 Byte | CRT | |
| 67 | C12.2 threshold switch input | Valuator | 1 Byte | CRT | |
| 67 | C12.2 threshold switch input | priority | 2 Bit | CRT | |
| 67 | C12.2 threshold switch input | Switching | 1 Bit | CRT | |
| 68 | Reserve | 1 Bit | CRWTU | ||
| 68 | C13 threshold switch input | 0..65535 | 2 Bytes | CRW | |
| 68 | C13 threshold switch input | EIS 5 | 2 Bytes | CRW | |
| 68 | C13 threshold switch input | Percent | 1 Byte | CRW | |
| 68 | C13 threshold switch input | 0..255 | 1 Byte | CRW | |
| 69 | Reserve | 1 Byte | CRWTU | ||
| 69 | C13 lock | lock = 1 | 1 Bit | CRW | |
| 69 | C13 lock | lock = 0 | 1 Bit | CRW | |
| 70 | Reserve | 1 Byte | CRWTU | ||
| 70 | C13.1 threshold switch | priority | 2 Bit | CRT | |
| 70 | C13.1 threshold switch | Switching | 1 Bit | CRT | |
| 70 | C13.1 threshold switch | Valuator | 1 Byte | CRT | |
| 71 | Reserve | 1 Bit | CRWTU | ||
| 71 | C13.2 threshold switch | Valuator | 1 Byte | CRT | |
| 71 | C13.2 threshold switch | priority | 2 Bit | CRT | |
| 71 | C13.2 threshold switch | Switching | 1 Bit | CRT | |
| 72 | Reserve | 1 Bit | CRWTU | ||
| 72 | C14 threshold switch input | 0..65535 | 2 Bytes | CRW | |
| 72 | C14 threshold switch input | EIS 5 | 2 Bytes | CRW | |
| 72 | C14 threshold switch input | Percent | 1 Byte | CRW | |
| 72 | C14 threshold switch input | 0..255 | 1 Byte | CRW | |
| 73 | Reserve | 1 Bit | CRWTU | ||
| 73 | C14 lock | lock = 0 | 1 Bit | CRW | |
| 73 | C14 lock | lock = 1 | 1 Bit | CRW | |
| 74 | Reserve | 2 Bytes | CRWTU | ||
| 74 | C14.1 threshold switch | priority | 2 Bit | CRT | |
| 74 | C14.1 threshold switch | Switching | 1 Bit | CRT | |
| 74 | C14.1 threshold switch | Valuator | 1 Byte | CRT | |
| 75 | Reserve | 2 Bytes | CRWTU | ||
| 75 | C14.2 threshold switch | Valuator | 1 Byte | CRT | |
| 75 | C14.2 threshold switch | priority | 2 Bit | CRT | |
| 75 | C14.2 threshold switch | Switching | 1 Bit | CRT | |
| 76 | C15 Logic module | Logic input 1 in XOR gate | 1 Bit | CRWU | |
| 76 | C15 Logic module | Logic input 1 in OR gate | 1 Bit | CRWU | |
| 76 | C15 Logic module | Logic input 1 in AND gate | 1 Bit | CRWU | |
| 76 | Reserve | Logic input 1 in XOR gate | 1 Bit | CRWTU | |
| 77 | C15 Logic module | Logic input 2 in XOR gate | 1 Bit | CRWU | |
| 77 | C15 Logic module | Logic input 2 in OR gate | 1 Bit | CRWU | |
| 77 | C15 Logic module | Logic input 2 in AND gate | 1 Bit | CRWU | |
| 77 | Reserve | Logic input 2 in XOR gate | 1 Byte | CRWTU | |
| 78 | C15 Logic module | Logic input 3 in AND gate | 1 Bit | CRWU | |
| 78 | C15 Logic module | Logic input 3 in OR gate | 1 Bit | CRWU | |
| 78 | Reserve | Logic input 3 in AND gate | 1 Byte | CRWTU | |
| 79 | C15 Logic module | Logic input 4 in OR gate | 1 Bit | CRWU | |
| 79 | C15 Logic module | Logic input 4 in AND gate | 1 Bit | CRWU | |
| 79 | Reserve | Logic input 4 in OR gate | 1 Bit | CRWTU | |
| 80 | C15 Logic module | lock = 0 | 1 Bit | CRW | |
| 80 | C15 Logic module | lock = 1 | 1 Bit | CRW | |
| 80 | Reserve | lock = 0 | 1 Bit | CRWTU | |
| 81 | C15.1 Logic module | Valuator | 1 Byte | CRT | |
| 81 | C15.1 Logic module | priority | 2 Bit | CRT | |
| 81 | C15.1 Logic module | Switching | 1 Bit | CRT | |
| 81 | Reserve | Valuator | 1 Bit | CRWTU | |
| 82 | C15.2 Logic module | Valuator | 1 Byte | CRT | |
| 82 | C15.2 Logic module | priority | 2 Bit | CRT | |
| 82 | C15.2 Logic module | Switching | 1 Bit | CRT | |
| 82 | Reserve | Valuator | 2 Bytes | CRWTU | |
| 83 | Reserve | 2 Bytes | CRWTU | ||
| 83 | C16 Logic module | Logic input 1 in OR gate | 1 Bit | CRWU | |
| 83 | C16 Logic module | Logic input 1 in AND gate | 1 Bit | CRWU | |
| 83 | C16 Logic module | Logic input 1 in XOR gate | 1 Bit | CRWU | |
| 84 | C16 Logic module | Logic input 2 in OR gate | 1 Bit | CRWU | |
| 84 | C16 Logic module | Logic input 2 in AND gate | 1 Bit | CRWU | |
| 84 | C16 Logic module | Logic input 2 in XOR gate | 1 Bit | CRWU | |
| 85 | C16 Logic module | Logic input 3 in OR gate | 1 Bit | CRWU | |
| 85 | C16 Logic module | Logic input 3 in AND gate | 1 Bit | CRWU | |
| 86 | C16 Logic module | Logic input 4 in OR gate | 1 Bit | CRWU | |
| 86 | C16 Logic module | Logic input 4 in AND gate | 1 Bit | CRWU | |
| 87 | C16 Logic module | lock = 0 | 1 Bit | CRW | |
| 87 | C16 Logic module | lock = 1 | 1 Bit | CRW | |
| 88 | C16.1 Logic module | priority | 2 Bit | CRT | |
| 88 | C16.1 Logic module | Switching | 1 Bit | CRT | |
| 88 | C16.1 Logic module | Valuator | 1 Byte | CRT | |
| 89 | C16.2 Logic module | Switching | 1 Bit | CRT | |
| 89 | C16.2 Logic module | Valuator | 1 Byte | CRT | |
| 89 | C16.2 Logic module | priority | 2 Bit | CRT | |
| 90 | C17 Logic module | Logic input 1 in OR gate | 1 Bit | CRWU | |
| 90 | C17 Logic module | Logic input 1 in AND gate | 1 Bit | CRWU | |
| 90 | C17 Logic module | Logic input 1 in XOR gate | 1 Bit | CRWU | |
| 91 | C17 Logic module | Logic input 2 in OR gate | 1 Bit | CRWU | |
| 91 | C17 Logic module | Logic input 2 in AND gate | 1 Bit | CRWU | |
| 91 | C17 Logic module | Logic input 2 in XOR gate | 1 Bit | CRWU | |
| 92 | C17 Logic module | Logic input 3 in OR gate | 1 Bit | CRWU | |
| 92 | C17 Logic module | Logic input 3 in AND gate | 1 Bit | CRWU | |
| 93 | C17 Logic module | Logic input 4 in OR gate | 1 Bit | CRWU | |
| 93 | C17 Logic module | Logic input 4 in AND gate | 1 Bit | CRWU | |
| 94 | C17 Logic module | lock = 1 | 1 Bit | CRW | |
| 94 | C17 Logic module | lock = 0 | 1 Bit | CRW | |
| 95 | C17.1 Logic module | priority | 2 Bit | CRT | |
| 95 | C17.1 Logic module | Switching | 1 Bit | CRT | |
| 95 | C17.1 Logic module | Valuator | 1 Byte | CRT | |
| 96 | C17.2 Logic module | Switching | 1 Bit | CRT | |
| 96 | C17.2 Logic module | Valuator | 1 Byte | CRT | |
| 96 | C17.2 Logic module | priority | 2 Bit | CRT | |
| 97 | C18 Logic module | Logic input 1 in OR gate | 1 Bit | CRWU | |
| 97 | C18 Logic module | Logic input 1 in AND gate | 1 Bit | CRWU | |
| 97 | C18 Logic module | Logic input 1 in XOR gate | 1 Bit | CRWU | |
| 98 | C18 Logic module | Logic input 2 in OR gate | 1 Bit | CRWU | |
| 98 | C18 Logic module | Logic input 2 in AND gate | 1 Bit | CRWU | |
| 98 | C18 Logic module | Logic input 2 in XOR gate | 1 Bit | CRWU | |
| 99 | C18 Logic module | Logic input 3 in OR gate | 1 Bit | CRWU | |
| 99 | C18 Logic module | Logic input 3 in AND gate | 1 Bit | CRWU | |
| 100 | C18 Logic module | Logic input 4 in OR gate | 1 Bit | CRWU | |
| 100 | C18 Logic module | Logic input 4 in AND gate | 1 Bit | CRWU | |
| 101 | C18 Logic module | lock = 0 | 1 Bit | CRW | |
| 101 | C18 Logic module | lock = 1 | 1 Bit | CRW | |
| 102 | C18.1 Logic module | priority | 2 Bit | CRT | |
| 102 | C18.1 Logic module | Switching | 1 Bit | CRT | |
| 102 | C18.1 Logic module | Valuator | 1 Byte | CRT | |
| 103 | C18.2 Logic module | Switching | 1 Bit | CRT | |
| 103 | C18.2 Logic module | Valuator | 1 Byte | CRT | |
| 103 | C18.2 Logic module | priority | 2 Bit | CRT | |
| 104 | C19 Logic module | Logic input 1 in OR gate | 1 Bit | CRWU | |
| 104 | C19 Logic module | Logic input 1 in AND gate | 1 Bit | CRWU | |
| 104 | C19 Logic module | Logic input 1 in XOR gate | 1 Bit | CRWU | |
| 105 | C19 Logic module | Logic input 2 in OR gate | 1 Bit | CRWU | |
| 105 | C19 Logic module | Logic input 2 in AND gate | 1 Bit | CRWU | |
| 105 | C19 Logic module | Logic input 2 in XOR gate | 1 Bit | CRWU | |
| 106 | C19 Logic module | Logic input 3 in OR gate | 1 Bit | CRWU | |
| 106 | C19 Logic module | Logic input 3 in AND gate | 1 Bit | CRWU | |
| 107 | C19 Logic module | Logic input 4 in OR gate | 1 Bit | CRWU | |
| 107 | C19 Logic module | Logic input 4 in AND gate | 1 Bit | CRWU | |
| 108 | C19 Logic module | lock = 1 | 1 Bit | CRW | |
| 108 | C19 Logic module | lock = 0 | 1 Bit | CRW | |
| 109 | C19.1 Logic module | priority | 2 Bit | CRT | |
| 109 | C19.1 Logic module | Switching | 1 Bit | CRT | |
| 109 | C19.1 Logic module | Valuator | 1 Byte | CRT | |
| 110 | C19.2 Logic module | Switching | 1 Bit | CRT | |
| 110 | C19.2 Logic module | Valuator | 1 Byte | CRT | |
| 110 | C19.2 Logic module | priority | 2 Bit | CRT | |
| 111 | C20 Logic module | Logic input 1 in AND gate | 1 Bit | CRWU | |
| 111 | C20 Logic module | Logic input 1 in XOR gate | 1 Bit | CRWU | |
| 111 | C20 Logic module | Logic input 1 in OR gate | 1 Bit | CRWU | |
| 112 | C20 Logic module | Logic input 2 in AND gate | 1 Bit | CRWU | |
| 112 | C20 Logic module | Logic input 2 in XOR gate | 1 Bit | CRWU | |
| 112 | C20 Logic module | Logic input 2 in OR gate | 1 Bit | CRWU | |
| 113 | C20 Logic module | Logic input 3 in AND gate | 1 Bit | CRWU | |
| 113 | C20 Logic module | Logic input 3 in OR gate | 1 Bit | CRWU | |
| 114 | C20 Logic module | Logic input 4 in AND gate | 1 Bit | CRWU | |
| 114 | C20 Logic module | Logic input 4 in OR gate | 1 Bit | CRWU | |
| 115 | C20 Logic module | lock = 0 | 1 Bit | CRW | |
| 115 | C20 Logic module | lock = 1 | 1 Bit | CRW | |
| 116 | C20.1 Logic module | priority | 2 Bit | CRT | |
| 116 | C20.1 Logic module | Switching | 1 Bit | CRT | |
| 116 | C20.1 Logic module | Valuator | 1 Byte | CRT | |
| 117 | C20.2 Logic module | Switching | 1 Bit | CRT | |
| 117 | C20.2 Logic module | Valuator | 1 Byte | CRT | |
| 117 | C20.2 Logic module | priority | 2 Bit | CRT |
Parameters (176)
| Parameter | Type | Default |
|---|---|---|
| Activate switching channel C1 | list | no |
| Activate switching channel C2 | list | no |
| Activate switching channel C3 | list | no |
| Activate switching channel C4 | list | no |
| Activate switching channel C5 | list | no |
| Activate switching channel C6 | list | no |
| Activate switching channel C7 | list | no |
| Activate switching channel C8 | list | no |
| Activate switching channel C9 | list | no |
| Activate switching channel C10 | list | no |
| Activate threshold channel C11 | list | no |
| Activate threshold channel C12 | list | no |
| Activate threshold channel C13 | list | no |
| Activate threshold channel C14 | list | no |
| Activate logic channel C15 | list | no |
| Activate logic channel C16 | list | no |
| Activate logic channel C17 | list | no |
| Activate logic channel C18 | list | no |
| Activate logic channel C19 | list | no |
| Activate logic channel C20 | list | no |
| Language after download | list | German |
| Backlit display after download | list | when operated |
| Device settings | list | enabled |
| Language after download | unsignedInt 0…16383 | 0 |
| PIN code 1000-9999 | unsignedInt 1000…9999 | 1234 |
| Weitere DATABUS Sensoren aktivieren? WIRD AUSGEBLENDET | list | no |
| Send brightness value on change | list | from 30 %, but at least 1 lx |
| Transmit brightness value and sensor status cyclically | list | do not send cyclically |
| Name for brightness sensor 1 (appears on screen) | text | Sensor 1 |
| Brightness calibration sensor 1 [%] | signedInt -30…30 | 0 |
| Name for brightness sensor 2 (appears on screen) | text | Sensor 2 |
| Transmit temperature in the event of change | list | from 1.0 °C |
| Brightness calibration sensor 2 [%] if available | signedInt -30…30 | 0 |
| Temperature calibration in 0.1 °C stages (-64 .. 63) | signedInt -64…63 | 0 |
| Name for brightness sensor 3 (appears on screen) | text | Sensor 3 |
| Send temperature cyclically | list | do not send cyclically |
| Brightness calibration sensor 3 [%] if available | signedInt -30…30 | 0 |
| Send wind speed in | list | m/s |
| Send wind speed in the event of a change | list | from 20 %, but at least 0.5 m/s |
| Send wind speed in the event of a change | list | On change of wind speed |
| Send wind speed in the event of a change | list | from 20 %, but at least 1.8 km/h |
| Send wind velocity value cyclically | list | do not send cyclically |
| Send rain in the event of change | list | Yes |
| Send rain cyclically | list | no |
| Empfindlichkeit des Regensensors | list | normal sensitivity |
| Off-delay | list | 1 min. |
| Activate dew suppression (rain sensor is always heated) | list | no |
| Channel name (appears on the display) | text | Schaltkanal 1 |
| Channel function | list | Brightness sensor 2 .. 100 000 lx |
| Brightness | list | no |
| Wenn Helligkeit | list | Temperature sensor |
| Wenn Temperatur | list | Temperature sensor |
| Temperature | list | no |
| Wind | list | no |
| Windgeschwindigkeit | list | Temperature sensor |
| Wenn es | list | Temperature sensor |
| Rain | list | no |
| Type of link | list | AND |
| Brightness threshold value | list | below 20 lx |
| Value can be overwritten via object | list | Yes |
| Value overwritten on download | list | Yes |
| Source | list | Sensor 1 |
| Light hysteresis | list | 20 %, but at least 1 lx |
| Delay when brightness increases | list | 3 min. |
| Delay when brightness decreases | list | 10 min. |
| Temperature | list | above 18 °C |
| Temperature hysteresis | list | 1.0 K |
| Temperature hysteresis | list | 1.0 °C |
| Wind speed | list | above 4 m/s (approx. 14 km/h) |
| Wind off-delay | list | 3 min. |
| Rain condition | list | it is raining |
| Verzögerung Regen | list | none |
| Telegram type C1.1 | list | switching command |
| If the condition is met | list | send following telegram once |
| Telegram | list | ON |
| Telegram | list | priority, ON (down) |
| Telegram | unsignedInt 0…255 | 255 |
| Text on screen | text | EIN |
| If the condition is not met | list | send following telegram once |
| Telegram | list | priority, OFF (up) |
| Telegram | list | OFF |
| Telegram | unsignedInt 0…255 | 0 |
| Text on screen | text | AUS |
| Should a second telegram be sent? | list | no |
| Telegram type C1.2 | list | switching command |
| When the brightness condition is met | list | send following telegram once |
| Activate lock function | list | no |
| Lock telegram | list | lock with ON telegram |
| Behaviour when setting the lock | list | do not send |
| Behaviour when cancelling the lock | list | update channel |
| Cycle time (if used) | list | Every 60 min. |
| Telegram on detection of sensor fault | list | do not send any longer |
| Channel name (appears on the display) | text | Schaltkanal 2 |
| Wenn Helligkeit | list | Brightness sensor |
| Wenn Temperatur | list | Brightness sensor |
| Windgeschwindigkeit | list | Brightness sensor |
| Wenn es | list | Brightness sensor |
| Verzögerung Regen | list | 1 min. |
| Telegram type C2.1 | list | switching command |
| Telegram type C2.2 | list | switching command |
| Channel name (appears on the display) | text | Schaltkanal 3 |
| Telegram type C3.1 | list | switching command |
| Telegram type C3.2 | list | switching command |
| Channel name (appears on the display) | text | Schaltkanal 4 |
| Wenn Helligkeit | list | Rain sensor |
| Wenn Temperatur | list | Rain sensor |
| Windgeschwindigkeit | list | Rain sensor |
| Wenn es | list | Rain sensor |
| Telegram type C4.1 | list | switching command |
| Telegram type C4.2 | list | switching command |
| Channel name (appears on the display) | text | Schaltkanal 5 |
| Telegram type C5.1 | list | switching command |
| Telegram type C5.2 | list | switching command |
| Channel name (appears on the display) | text | Schaltkanal 6 |
| Telegram type C6.1 | list | switching command |
| Telegram type C6.2 | list | switching command |
| Channel name (appears on the display) | text | Schaltkanal 7 |
| Telegram type C7.1 | list | switching command |
| Telegram type C7.2 | list | switching command |
| Channel name (appears on the display) | text | Schaltkanal 8 |
| Wenn Helligkeit | list | Wind sensor |
| Wenn Temperatur | list | Wind sensor |
| Windgeschwindigkeit | list | Wind sensor |
| Wenn es | list | Wind sensor |
| Telegram type C8.1 | list | switching command |
| Telegram type C8.2 | list | switching command |
| Channel name (appears on the display) | text | Schaltkanal 9 |
| Telegram type C9.1 | list | switching command |
| Telegram type C9.2 | list | switching command |
| Channel name (appears on the display) | text | Schaltkanal 10 |
| Telegram type C10.1 | list | switching command |
| Telegram type C10.2 | list | switching command |
| Type of threshold value object | list | object type: Per cent (DPT 5.001) |
| Threshold value format: (-)000.00.. 99999 | text | 20,0 |
| Threshold value (in %) | unsignedInt 1…99 | 50 |
| Threshold value | unsignedInt 1…254 | 127 |
| Threshold value | unsignedInt 1…65534 | 1000 |
| Hysteresis format: 0.00..9999 | text | 1,0 |
| Hysteresis (as %) | unsignedInt 1…99 | 5 |
| Hysteresis | unsignedInt 1…254 | 5 |
| Hysteresis | unsignedInt 1…65534 | 5 |
| Delay with exceeding | list | none |
| Delay with falling below | list | none |
| Telegram type C11.1 | list | switching command |
| When exceeding the threshold | list | send following telegram once |
| When underrunning threshold | list | send following telegram once |
| Telegram type C11.2 | list | switching command |
| Telegram after reset or download | list | as with unfulfilled condition |
| Telegram type C12.1 | list | switching command |
| Telegram type C12.2 | list | switching command |
| Telegram type C13.1 | list | switching command |
| Telegram type C13.2 | list | switching command |
| Telegram type C14.1 | list | switching command |
| Telegram type C14.2 | list | switching command |
| Use input 1 | list | Yes |
| Use input 2 | list | Yes |
| Use input 3 | list | no |
| Use input 4 | list | no |
| Source for input 1 | list | input object |
| Source for input 2 | list | input object |
| Source for input 3 | list | input object |
| Source for input 4 | list | input object |
| Telegram type C15.1 | list | switching command |
| Telegram type C15.2 | list | switching command |
| Ausgang invertieren | list | no |
| Telegram type C16.1 | list | switching command |
| Telegram type C16.2 | list | switching command |
| Telegram type C17.1 | list | switching command |
| Telegram type C17.2 | list | switching command |
| Telegram type C18.1 | list | switching command |
| Telegram type C18.2 | list | switching command |
| Telegram type C19.1 | list | switching command |
| Telegram type C19.2 | list | switching command |
| Telegram type C20.1 | list | switching command |
| Telegram type C20.2 | list | switching command |
| Wert $AA, so erkennt Controller, dass Ap plikation neu runtergeladen wurde | unsignedInt 0…255 | 170 |
Version history
| Application | App no | Fingerprint | First seen | Size | File |
|---|---|---|---|---|---|
| Brightness Sensor 4C/1.0a 1.0 latest | $134A | 2A22 | 2026-11-25 | 307 KB | Download |
About this file
This is the official ETS product database for the ABB AG - STOTZ-KONTAKT HS/S4.2.1 Outside Light Sensor Interface,MDRC (2CDG 120 044 R0011), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.
More from ABB AG - STOTZ-KONTAKT
- DG/S8.1 DALI Gateway,8-fold,MDRC 2CDG 110 025 R0011
- SD/S2.16.1 Switch/Dim Actuator, 2-fold, MDRC 2CDG 110 079 R0011
- SD/S4.16.1 Switch/Dim Actuator, 4-fold, MDRC 2CDG 110 080 R0011
- SD/S8.16.1 Switch/Dim Actuator, 8-fold, MDRC 2CDG 110 081 R0011
- DLR/S8.16.1M DALI Light Controller,8f,MDRC 2CDG 110 101 R0011
- DLR/A4.8.1.1 DALI Light Controller,4-fold,SM 2CDG 110 172 R0011
- DG/S1.64.1.1 DALI Gateway,Basic,1f,MDRC 2CDG 110 198 R0011
- DG/S2.64.1.1 DALI Gateway,Basic,2f,MDRC 2CDG 110 199 R0011
- DG/S1.64.5.1 DALI Gateway,Premium,1f,MDRC 2CDG 110 273 R0011
- DG/S2.64.5.1 DALI Gateway,Premium,2f,MDRC 2CDG 110 274 R0011
- LR/S2.16.1 Light Controller,2f,1-10V,16A,MDRC 2CDG110 087 R0011
- LR/S4.16.1 Light Controller,4f,1-10V,16A,MDRC 2CDG110 088 R0011