KNX Database
ABB AG - STOTZ-KONTAKT 2CDG 110 280 R0011 BE/S8.230.3.2 Binary Input, 8-fold, 230V AC/DC, MDRC

BE/S8.230.3.2 Binary Input, 8-fold, 230V AC/DC, MDRC 2CDG 110 280 R0011

ABB AG - STOTZ-KONTAKT · Order number 2CDG 110 280 R0011 · Standard Inputs › Binary Inputs AC/DC

Download .knxprod Binary Input 8f 230V/1.0 1.0 · 1.4 MB

Product

ManufacturerABB AG - STOTZ-KONTAKT
Product nameBE/S8.230.3.2 Binary Input, 8-fold, 230V AC/DC, MDRC
Order number2CDG 110 280 R0011
HardwareBE/S8.230.3.2 Binary Input, 8-fold, 230V AC/DC, MDRC
MediumTwisted Pair
Bus current (mA)10
Rail mountedYes
Width (mm)70
RegistrationRegistered · 2024-10-02
Languagesen-US, de-DE, es-ES, fr-FR, it-IT, nl-NL, pl-PL, ru-RU
Catalog entryM-0002_H-2CDG.20110.20280.20R0011-1_HP-A0EA-10-90D5-A0EA-20-EB57_CI-2CDG.20110.20280.20R0011-1
Fingerprint90D5
SHA-256bc2885f4727f19fbdbfba5be74ccad47d6a3496862e46e1625402094b15bb18e
First seen2026-11-25
Markets59 markets

Application program: Binary Input 8f 230V/1.0 1.0

Application number$A0EA
Version1.0
Mask versionMV-07B0 (System B)
KNX Data SecureYes
Minimum ETS version5.0
Parameters9047
Group objects1168
Group objects (1168)
NoNameFunctionSizeDPTFlags
1Central – General: In operation1 Bit1.2 booleanCRT
2Central – Date/time: Set time3 Bytes10.1 time of dayCW
3Central – Date/time: Set date3 Bytes11.1 dateCW
4Central – Date/time: Set date/time8 Bytes19.1 date timeCW
5Central – Date/time: Request date/time1 Bit1.17 triggerCT
6Central – Manual operation: Status Manual operation1 Bit1.11 stateCRT
7Central – Manual operation: Enable/block manual operation1 Bit1.3 enableCW
8Central – Manual operation: Deactivate Manual operation1 Bit1.17 triggerCW
9Logic – Connection 1: Connection A1 Bit1.2 booleanCWTU
10Logic – Connection 1: Connection B1 Bit1.2 booleanCWTU
11Logic – Result 1: Status Result1 Bit1.2 booleanCRT
12Logic – Block 1: Block logic1 Bit1.3 enableCW
13Logic – Request 1: Request status values1 Bit1.17 triggerCW
14Logic – Connection 2: Connection A1 Bit1.2 booleanCWTU
15Logic – Connection 2: Connection B1 Bit1.2 booleanCWTU
16Logic – Result 2: Status Result1 Bit1.2 booleanCRT
17Logic – Block 2: Block logic1 Bit1.3 enableCW
18Logic – Request 2: Request status values1 Bit1.17 triggerCW
19Logic – Connection 3: Connection A1 Bit1.2 booleanCWTU
20Logic – Connection 3: Connection B1 Bit1.2 booleanCWTU
21Logic – Result 3: Status Result1 Bit1.2 booleanCRT
22Logic – Block 3: Block logic1 Bit1.3 enableCW
23Logic – Request 3: Request status values1 Bit1.17 triggerCW
24Logic – Connection 4: Connection A1 Bit1.2 booleanCWTU
25Logic – Connection 4: Connection B1 Bit1.2 booleanCWTU
26Logic – Result 4: Status Result1 Bit1.2 booleanCRT
27Logic – Block 4: Block logic1 Bit1.3 enableCW
28Logic – Request 4: Request status values1 Bit1.17 triggerCW
29Logic – Connection 5: Connection A1 Bit1.2 booleanCWTU
30Logic – Connection 5: Connection B1 Bit1.2 booleanCWTU
31Logic – Result 5: Status Result1 Bit1.2 booleanCRT
32Logic – Block 5: Block logic1 Bit1.3 enableCW
33Logic – Request 5: Request status values1 Bit1.17 triggerCW
34Logic – Connection 6: Connection A1 Bit1.2 booleanCWTU
35Logic – Connection 6: Connection B1 Bit1.2 booleanCWTU
36Logic – Result 6: Status Result1 Bit1.2 booleanCRT
37Logic – Block 6: Block logic1 Bit1.3 enableCW
38Logic – Request 6: Request status values1 Bit1.17 triggerCW
39Logic – Connection 7: Connection A1 Bit1.2 booleanCWTU
40Logic – Connection 7: Connection B1 Bit1.2 booleanCWTU
41Logic – Result 7: Status Result1 Bit1.2 booleanCRT
42Logic – Block 7: Block logic1 Bit1.3 enableCW
43Logic – Request 7: Request status values1 Bit1.17 triggerCW
44Logic – Connection 8: Connection A1 Bit1.2 booleanCWTU
45Logic – Connection 8: Connection B1 Bit1.2 booleanCWTU
46Logic – Result 8: Status Result1 Bit1.2 booleanCRT
47Logic – Block 8: Block logic1 Bit1.3 enableCW
48Logic – Request 8: Request status values1 Bit1.17 triggerCW
49Input a – Switch: {{0}}Switch1 Bit1.1 switchCWTU
49Input a+b – Switch: {{0}}Switch1 Bit1.1 switchCWTU
49Input a – Blind/shutter: {{0}}Up/down1 Bit1.8 up/downCWTU
49Input a+b – Blind/shutter: {{0}}Up/down1 Bit1.8 up/downCWTU
49Input a – Switch/dim: {{0}}Dimming4 Bit3.7 dimming controlCT
49Input a+b – Switch/dim: {{0}}Dimming4 Bit3.7 dimming controlCT
49Input a – Scene: {{0}}Scene 1…641 Byte18.1 scene controlCT
49Input a – Send value: {{0}}Value 1: Switch1 Bit1.1 switchCWTU
49Input a – Send value: {{0}}Value 1: Percent1 Byte5.1 percentage (0..100%)CWTU
49Input a – Send value: {{0}}Value 1: Forced operation2 Bit2.1 switch controlCRWT
49Input a – Send value: {{0}}Value 1: Temperature2 Bytes9.1 temperature (°C)CWTU
49Input a – Send value: {{0}}Value 1: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
49Input a – Send value: {{0}}Value 1: HVAC mode1 Byte20.102 HVAC modeCWTU
49Input a – Send value: {{0}}Value 1: 1 byte1 Byte5.10 counter pulses (0..255)CWTU
49Input a – Send value: {{0}}Value 1: 1 byte signed1 Byte6.10 counter pulses (-128..127)CWTU
49Input a – Send value: {{0}}Value 1: 2 bytes2 Bytes7.1 pulsesCWTU
49Input a – Send value: {{0}}Value 1: 2 bytes signed2 Bytes8.1 pulses differenceCWTU
49Input a – Send value: {{0}}Value 1: 4 bytes4 Bytes12.1 counter pulses (unsigned)CWTU
49Input a – Fault indicator/logic input: {{0}}Status Fault1 Bit1.11 stateCRWT
49Input a – Switching sequence: {{0}}Value 1: Switch1 Bit1.1 switchCWTU
49Input a – Switching sequence: {{0}}Value 1: Percent1 Byte5.1 percentage (0..100%)CWTU
49Input a – Switching sequence: {{0}}Value 1: Byte1 Byte5.10 counter pulses (0..255)CWTU
49Input a – Switching sequence: {{0}}Value 1: Scene1 Byte18.1 scene controlCWTU
49Input a – Switching sequence: {{0}}Value 1: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
49Input a – Switching sequence: {{0}}Value 1: HVAC mode1 Byte20.102 HVAC modeCWTU
49Input a+b – Switching sequence: {{0}}Value 1: Switch1 Bit1.1 switchCWTU
49Input a+b – Switching sequence: {{0}}Value 1: Percent1 Byte5.1 percentage (0..100%)CWTU
49Input a+b – Switching sequence: {{0}}Value 1: Byte1 Byte5.10 counter pulses (0..255)CWTU
49Input a+b – Switching sequence: {{0}}Value 1: Scene1 Byte18.1 scene controlCWTU
49Input a+b – Switching sequence: {{0}}Value 1: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
49Input a+b – Switching sequence: {{0}}Value 1: HVAC mode1 Byte20.102 HVAC modeCWTU
49Input a – Pulse counter 1: {{0}}Counter value1 Byte6.10 counter pulses (-128..127)CRT
49Input a – Pulse counter 1: {{0}}Counter value1 Byte5.10 counter pulses (0..255)CRT
49Input a – Pulse counter 1: {{0}}Counter value2 Bytes8.1 pulses differenceCRT
49Input a – Pulse counter 1: {{0}}Counter value2 Bytes7.1 pulsesCRT
49Input a – Pulse counter 1: {{0}}Counter value4 Bytes13.1 counter pulses (signed)CRT
49Input a – Pulse counter 1: {{0}}Counter value4 Bytes12.1 counter pulses (unsigned)CRT
50Input a – Switch: {{0}}Block1 Bit1.3 enableCW
50Input a+b – Switch: {{0}}Block1 Bit1.3 enableCW
50Input a – Blind/shutter: {{0}}Step/stop1 Bit1.7 stepCWTU
50Input a – Blind/shutter: {{0}}Stop1 Bit1.17 triggerCWTU
50Input a+b – Blind/shutter: {{0}}Step/stop1 Bit1.7 stepCWTU
50Input a+b – Blind/shutter: {{0}}Stop1 Bit1.17 triggerCWTU
50Input a – Switch/dim: {{0}}Switch1 Bit1.1 switchCWTU
50Input a+b – Switch/dim: {{0}}Switch1 Bit1.1 switchCWTU
50Input a – Scene: {{0}}Block1 Bit1.3 enableCW
50Input a – Send value: {{0}}Value 2: Switch1 Bit1.1 switchCWTU
50Input a – Send value: {{0}}Value 2: Percent1 Byte5.1 percentage (0..100%)CWTU
50Input a – Send value: {{0}}Value 2: Forced operation2 Bit2.1 switch controlCRWT
50Input a – Send value: {{0}}Value 2: Temperature2 Bytes9.1 temperature (°C)CWTU
50Input a – Send value: {{0}}Value 2: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
50Input a – Send value: {{0}}Value 2: HVAC mode1 Byte20.102 HVAC modeCWTU
50Input a – Send value: {{0}}Value 2: 1 byte1 Byte5.10 counter pulses (0..255)CWTU
50Input a – Send value: {{0}}Value 2: 1 byte signed1 Byte6.10 counter pulses (-128..127)CWTU
50Input a – Send value: {{0}}Value 2: 2 bytes2 Bytes7.1 pulsesCWTU
50Input a – Send value: {{0}}Value 2: 2 bytes signed2 Bytes8.1 pulses differenceCWTU
50Input a – Send value: {{0}}Value 2: 4 bytes4 Bytes12.1 counter pulses (unsigned)CWTU
50Input a – Fault indicator/logic input: {{0}}Block1 Bit1.3 enableCW
50Input a – Switching sequence: {{0}}Value 2: Switch1 Bit1.1 switchCWTU
50Input a – Switching sequence: {{0}}Value 2: Percent1 Byte5.1 percentage (0..100%)CWTU
50Input a – Switching sequence: {{0}}Value 2: Byte1 Byte5.10 counter pulses (0..255)CWTU
50Input a – Switching sequence: {{0}}Value 2: Scene1 Byte18.1 scene controlCWTU
50Input a – Switching sequence: {{0}}Value 2: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
50Input a – Switching sequence: {{0}}Value 2: HVAC mode1 Byte20.102 HVAC modeCWTU
50Input a+b – Switching sequence: {{0}}Value 2: Switch1 Bit1.1 switchCWTU
50Input a+b – Switching sequence: {{0}}Value 2: Percent1 Byte5.1 percentage (0..100%)CWTU
50Input a+b – Switching sequence: {{0}}Value 2: Byte1 Byte5.10 counter pulses (0..255)CWTU
50Input a+b – Switching sequence: {{0}}Value 2: Scene1 Byte18.1 scene controlCWTU
50Input a+b – Switching sequence: {{0}}Value 2: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
50Input a+b – Switching sequence: {{0}}Value 2: HVAC mode1 Byte20.102 HVAC modeCWTU
50Input a – Pulse counter 1: {{0}}Reset counter value1 Bit1.15 resetCW
51Input a – Switch: {{0}}Switch 21 Bit1.1 switchCWTU
51Input a+b – Blind/shutter: {{0}}Status Upper end position1 Bit1.2 booleanCWU
51Input a+b – Switch/dim: {{0}}Block1 Bit1.3 enableCW
51Input a – Send value: {{0}}Value 3: Switch1 Bit1.1 switchCWTU
51Input a – Send value: {{0}}Value 3: Percent1 Byte5.1 percentage (0..100%)CWTU
51Input a – Send value: {{0}}Value 3: Forced operation2 Bit2.1 switch controlCWTU
51Input a – Send value: {{0}}Value 3: Temperature2 Bytes9.1 temperature (°C)CWTU
51Input a – Send value: {{0}}Value 3: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
51Input a – Send value: {{0}}Value 3: HVAC mode1 Byte20.102 HVAC modeCWTU
51Input a – Send value: {{0}}Value 3: 1 byte1 Byte5.10 counter pulses (0..255)CWTU
51Input a – Send value: {{0}}Value 3: 1 byte signed1 Byte6.10 counter pulses (-128..127)CWTU
51Input a – Send value: {{0}}Value 3: 2 bytes2 Bytes7.1 pulsesCWTU
51Input a – Send value: {{0}}Value 3: 2 bytes signed2 Bytes8.1 pulses differenceCWTU
51Input a – Send value: {{0}}Value 3: 4 bytes4 Bytes12.1 counter pulses (unsigned)CWTU
51Input a – Fault indicator/logic input: {{0}}Request status Fault1 Bit1.17 triggerCW
51Input a – Switching sequence: {{0}}Value 3: Switch1 Bit1.1 switchCWTU
51Input a – Switching sequence: {{0}}Value 3: Percent1 Byte5.1 percentage (0..100%)CWTU
51Input a – Switching sequence: {{0}}Value 3: Byte1 Byte5.10 counter pulses (0..255)CWTU
51Input a – Switching sequence: {{0}}Value 3: Scene1 Byte18.1 scene controlCWTU
51Input a – Switching sequence: {{0}}Value 3: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
51Input a – Switching sequence: {{0}}Value 3: HVAC mode1 Byte20.102 HVAC modeCWTU
51Input a+b – Switching sequence: {{0}}Value 3: Switch1 Bit1.1 switchCWTU
51Input a+b – Switching sequence: {{0}}Value 3: Percent1 Byte5.1 percentage (0..100%)CWTU
51Input a+b – Switching sequence: {{0}}Value 3: Byte1 Byte5.10 counter pulses (0..255)CWTU
51Input a+b – Switching sequence: {{0}}Value 3: Scene1 Byte18.1 scene controlCWTU
51Input a+b – Switching sequence: {{0}}Value 3: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
51Input a+b – Switching sequence: {{0}}Value 3: HVAC mode1 Byte20.102 HVAC modeCWTU
51Input a – Pulse counter 1: {{0}}Request counter value1 Bit1.17 triggerCW
52Input a – Switch: {{0}}Block 21 Bit1.3 enableCW
52Input a – Blind/shutter: {{0}}Status Upper end position1 Bit1.2 booleanCWU
52Input a+b – Blind/shutter: {{0}}Status Lower end position1 Bit1.2 booleanCWU
52Input a – Switch/dim: {{0}}Block1 Bit1.3 enableCW
52Input a – Send value: {{0}}Value 4: Switch1 Bit1.1 switchCWTU
52Input a – Send value: {{0}}Value 4: Percent1 Byte5.1 percentage (0..100%)CWTU
52Input a – Send value: {{0}}Value 4: Forced operation2 Bit2.1 switch controlCWTU
52Input a – Send value: {{0}}Value 4: Temperature2 Bytes9.1 temperature (°C)CWTU
52Input a – Send value: {{0}}Value 4: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
52Input a – Send value: {{0}}Value 4: HVAC mode1 Byte20.102 HVAC modeCWTU
52Input a – Send value: {{0}}Value 4: 1 byte1 Byte5.10 counter pulses (0..255)CWTU
52Input a – Send value: {{0}}Value 4: 1 byte signed1 Byte6.10 counter pulses (-128..127)CWTU
52Input a – Send value: {{0}}Value 4: 2 bytes2 Bytes7.1 pulsesCWTU
52Input a – Send value: {{0}}Value 4: 2 bytes signed2 Bytes8.1 pulses differenceCWTU
52Input a – Send value: {{0}}Value 4: 4 bytes4 Bytes12.1 counter pulses (unsigned)CWTU
52Input a – Switching sequence: {{0}}Value 4: Switch1 Bit1.1 switchCWTU
52Input a – Switching sequence: {{0}}Value 4: Percent1 Byte5.1 percentage (0..100%)CWTU
52Input a – Switching sequence: {{0}}Value 4: Byte1 Byte5.10 counter pulses (0..255)CWTU
52Input a – Switching sequence: {{0}}Value 4: Scene1 Byte18.1 scene controlCWTU
52Input a – Switching sequence: {{0}}Value 4: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
52Input a – Switching sequence: {{0}}Value 4: HVAC mode1 Byte20.102 HVAC modeCWTU
52Input a+b – Switching sequence: {{0}}Value 4: Switch1 Bit1.1 switchCWTU
52Input a+b – Switching sequence: {{0}}Value 4: Percent1 Byte5.1 percentage (0..100%)CWTU
52Input a+b – Switching sequence: {{0}}Value 4: Byte1 Byte5.10 counter pulses (0..255)CWTU
52Input a+b – Switching sequence: {{0}}Value 4: Scene1 Byte18.1 scene controlCWTU
52Input a+b – Switching sequence: {{0}}Value 4: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
52Input a+b – Switching sequence: {{0}}Value 4: HVAC mode1 Byte20.102 HVAC modeCWTU
52Input a – Pulse counter 1: {{0}}Limit value reached1 Bit1.2 booleanCRT
53Input a – Blind/shutter: {{0}}Status Lower end position1 Bit1.2 booleanCWU
53Input a+b – Blind/shutter: {{0}}Status Move1 Bit1.2 booleanCWU
53Input a – Send value: {{0}}Block1 Bit1.3 enableCWTU
53Input a – Switching sequence: {{0}}Value 5: Switch1 Bit1.1 switchCWTU
53Input a – Switching sequence: {{0}}Value 5: Percent1 Byte5.1 percentage (0..100%)CWTU
53Input a – Switching sequence: {{0}}Value 5: Byte1 Byte5.10 counter pulses (0..255)CWTU
53Input a – Switching sequence: {{0}}Value 5: Scene1 Byte18.1 scene controlCWTU
53Input a – Switching sequence: {{0}}Value 5: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
53Input a – Switching sequence: {{0}}Value 5: HVAC mode1 Byte20.102 HVAC modeCWTU
53Input a+b – Switching sequence: {{0}}Value 5: Switch1 Bit1.1 switchCWTU
53Input a+b – Switching sequence: {{0}}Value 5: Percent1 Byte5.1 percentage (0..100%)CWTU
53Input a+b – Switching sequence: {{0}}Value 5: Byte1 Byte5.10 counter pulses (0..255)CWTU
53Input a+b – Switching sequence: {{0}}Value 5: Scene1 Byte18.1 scene controlCWTU
53Input a+b – Switching sequence: {{0}}Value 5: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
53Input a+b – Switching sequence: {{0}}Value 5: HVAC mode1 Byte20.102 HVAC modeCWTU
53Input a – Pulse counter 2: {{0}}Counter value1 Byte6.10 counter pulses (-128..127)CRT
53Input a – Pulse counter 2: {{0}}Counter value1 Byte5.10 counter pulses (0..255)CRT
53Input a – Pulse counter 2: {{0}}Counter value2 Bytes8.1 pulses differenceCRT
53Input a – Pulse counter 2: {{0}}Counter value2 Bytes7.1 pulsesCRT
53Input a – Pulse counter 2: {{0}}Counter value4 Bytes13.1 counter pulses (signed)CRT
53Input a – Pulse counter 2: {{0}}Counter value4 Bytes12.1 counter pulses (unsigned)CRT
54Input a – Blind/shutter: {{0}}Status Move1 Bit1.2 booleanCWU
54Input a+b – Blind/shutter: {{0}}Block1 Bit1.3 enableCW
54Input a – Switching sequence: {{0}}Number of operations1 Byte5.10 counter pulses (0..255)CWTU
54Input a+b – Switching sequence: {{0}}Number of operations1 Byte5.10 counter pulses (0..255)CWTU
54Input a – Pulse counter 2: {{0}}Reset counter value1 Bit1.15 resetCW
55Input a – Blind/shutter: {{0}}Block1 Bit1.3 enableCW
55Input a – Switching sequence: {{0}}Reset switching sequence1 Bit1.17 triggerCW
55Input a+b – Switching sequence: {{0}}Reset switching sequence1 Bit1.17 triggerCW
55Input a – Pulse counter 2: {{0}}Request counter value1 Bit1.17 triggerCW
56Input a – Switching sequence: {{0}}Next/previous step1 Bit1.7 stepCW
56Input a+b – Switching sequence: {{0}}Next/previous step1 Bit1.7 stepCW
56Input a – Pulse counter 2: {{0}}Limit value reached1 Bit1.2 booleanCRT
57Input a – Switching sequence: {{0}}Block1 Bit1.3 enableCW
57Input a+b – Switching sequence: {{0}}Block1 Bit1.3 enableCW
57Input a – Pulse counter: {{0}}Block1 Bit1.3 enableCW
58Input b – Switch: {{0}}Switch1 Bit1.1 switchCWTU
58Input b – Blind/shutter: {{0}}Up/down1 Bit1.8 up/downCWTU
58Input b – Switch/dim: {{0}}Dimming4 Bit3.7 dimming controlCT
58Input b – Scene: {{0}}Scene 1…641 Byte18.1 scene controlCT
58Input b – Send value: {{0}}Value 1: Switch1 Bit1.1 switchCWTU
58Input b – Send value: {{0}}Value 1: Percent1 Byte5.1 percentage (0..100%)CWTU
58Input b – Send value: {{0}}Value 1: Forced operation2 Bit2.1 switch controlCRWT
58Input b – Send value: {{0}}Value 1: Temperature2 Bytes9.1 temperature (°C)CWTU
58Input b – Send value: {{0}}Value 1: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
58Input b – Send value: {{0}}Value 1: HVAC mode1 Byte20.102 HVAC modeCWTU
58Input b – Send value: {{0}}Value 1: 1 byte1 Byte5.10 counter pulses (0..255)CWTU
58Input b – Send value: {{0}}Value 1: 1 byte signed1 Byte6.10 counter pulses (-128..127)CWTU
58Input b – Send value: {{0}}Value 1: 2 bytes2 Bytes7.1 pulsesCWTU
58Input b – Send value: {{0}}Value 1: 2 bytes signed2 Bytes8.1 pulses differenceCWTU
58Input b – Send value: {{0}}Value 1: 4 bytes4 Bytes12.1 counter pulses (unsigned)CWTU
58Input b – Fault indicator/logic input: {{0}}Status Fault1 Bit1.11 stateCRWT
58Input b – Switching sequence: {{0}}Value 1: Switch1 Bit1.1 switchCWTU
58Input b – Switching sequence: {{0}}Value 1: Percent1 Byte5.1 percentage (0..100%)CWTU
58Input b – Switching sequence: {{0}}Value 1: Byte1 Byte5.10 counter pulses (0..255)CWTU
58Input b – Switching sequence: {{0}}Value 1: Scene1 Byte18.1 scene controlCWTU
58Input b – Switching sequence: {{0}}Value 1: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
58Input b – Switching sequence: {{0}}Value 1: HVAC mode1 Byte20.102 HVAC modeCWTU
58Input b – Pulse counter 1: {{0}}Counter value1 Byte6.10 counter pulses (-128..127)CRT
58Input b – Pulse counter 1: {{0}}Counter value1 Byte5.10 counter pulses (0..255)CRT
58Input b – Pulse counter 1: {{0}}Counter value2 Bytes8.1 pulses differenceCRT
58Input b – Pulse counter 1: {{0}}Counter value2 Bytes7.1 pulsesCRT
58Input b – Pulse counter 1: {{0}}Counter value4 Bytes13.1 counter pulses (signed)CRT
58Input b – Pulse counter 1: {{0}}Counter value4 Bytes12.1 counter pulses (unsigned)CRT
59Input b – Switch: {{0}}Block1 Bit1.3 enableCW
59Input b – Blind/shutter: {{0}}Step/stop1 Bit1.7 stepCWTU
59Input b – Blind/shutter: {{0}}Stop1 Bit1.17 triggerCWTU
59Input b – Switch/dim: {{0}}Switch1 Bit1.1 switchCWTU
59Input b – Scene: {{0}}Block1 Bit1.3 enableCW
59Input b – Send value: {{0}}Value 2: Switch1 Bit1.1 switchCWTU
59Input b – Send value: {{0}}Value 2: Percent1 Byte5.1 percentage (0..100%)CWTU
59Input b – Send value: {{0}}Value 2: Forced operation2 Bit2.1 switch controlCRWT
59Input b – Send value: {{0}}Value 2: Temperature2 Bytes9.1 temperature (°C)CWTU
59Input b – Send value: {{0}}Value 2: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
59Input b – Send value: {{0}}Value 2: HVAC mode1 Byte20.102 HVAC modeCWTU
59Input b – Send value: {{0}}Value 2: 1 byte1 Byte5.10 counter pulses (0..255)CWTU
59Input b – Send value: {{0}}Value 2: 1 byte signed1 Byte6.10 counter pulses (-128..127)CWTU
59Input b – Send value: {{0}}Value 2: 2 bytes2 Bytes7.1 pulsesCWTU
59Input b – Send value: {{0}}Value 2: 2 bytes signed2 Bytes8.1 pulses differenceCWTU
59Input b – Send value: {{0}}Value 2: 4 bytes4 Bytes12.1 counter pulses (unsigned)CWTU
59Input b – Fault indicator/logic input: {{0}}Block1 Bit1.3 enableCW
59Input b – Switching sequence: {{0}}Value 2: Switch1 Bit1.1 switchCWTU
59Input b – Switching sequence: {{0}}Value 2: Percent1 Byte5.1 percentage (0..100%)CWTU
59Input b – Switching sequence: {{0}}Value 2: Byte1 Byte5.10 counter pulses (0..255)CWTU
59Input b – Switching sequence: {{0}}Value 2: Scene1 Byte18.1 scene controlCWTU
59Input b – Switching sequence: {{0}}Value 2: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
59Input b – Switching sequence: {{0}}Value 2: HVAC mode1 Byte20.102 HVAC modeCWTU
59Input b – Pulse counter 1: {{0}}Reset counter value1 Bit1.15 resetCW
60Input b – Switch: {{0}}Switch 21 Bit1.1 switchCWTU
60Input b – Send value: {{0}}Value 3: Switch1 Bit1.1 switchCWTU
60Input b – Send value: {{0}}Value 3: Percent1 Byte5.1 percentage (0..100%)CWTU
60Input b – Send value: {{0}}Value 3: Forced operation2 Bit2.1 switch controlCWTU
60Input b – Send value: {{0}}Value 3: Temperature2 Bytes9.1 temperature (°C)CWTU
60Input b – Send value: {{0}}Value 3: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
60Input b – Send value: {{0}}Value 3: HVAC mode1 Byte20.102 HVAC modeCWTU
60Input b – Send value: {{0}}Value 3: 1 byte1 Byte5.10 counter pulses (0..255)CWTU
60Input b – Send value: {{0}}Value 3: 1 byte signed1 Byte6.10 counter pulses (-128..127)CWTU
60Input b – Send value: {{0}}Value 3: 2 bytes2 Bytes7.1 pulsesCWTU
60Input b – Send value: {{0}}Value 3: 2 bytes signed2 Bytes8.1 pulses differenceCWTU
60Input b – Send value: {{0}}Value 3: 4 bytes4 Bytes12.1 counter pulses (unsigned)CWTU
60Input b – Fault indicator/logic input: {{0}}Request status Fault1 Bit1.17 triggerCW
60Input b – Switching sequence: {{0}}Value 3: Switch1 Bit1.1 switchCWTU
60Input b – Switching sequence: {{0}}Value 3: Percent1 Byte5.1 percentage (0..100%)CWTU
60Input b – Switching sequence: {{0}}Value 3: Byte1 Byte5.10 counter pulses (0..255)CWTU
60Input b – Switching sequence: {{0}}Value 3: Scene1 Byte18.1 scene controlCWTU
60Input b – Switching sequence: {{0}}Value 3: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
60Input b – Switching sequence: {{0}}Value 3: HVAC mode1 Byte20.102 HVAC modeCWTU
60Input b – Pulse counter 1: {{0}}Request counter value1 Bit1.17 triggerCW
61Input b – Switch: {{0}}Block 21 Bit1.3 enableCW
61Input b – Blind/shutter: {{0}}Status Upper end position1 Bit1.2 booleanCWU
61Input b – Switch/dim: {{0}}Block1 Bit1.3 enableCW
61Input b – Send value: {{0}}Value 4: Switch1 Bit1.1 switchCWTU
61Input b – Send value: {{0}}Value 4: Percent1 Byte5.1 percentage (0..100%)CWTU
61Input b – Send value: {{0}}Value 4: Forced operation2 Bit2.1 switch controlCWTU
61Input b – Send value: {{0}}Value 4: Temperature2 Bytes9.1 temperature (°C)CWTU
61Input b – Send value: {{0}}Value 4: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
61Input b – Send value: {{0}}Value 4: HVAC mode1 Byte20.102 HVAC modeCWTU
61Input b – Send value: {{0}}Value 4: 1 byte1 Byte5.10 counter pulses (0..255)CWTU
61Input b – Send value: {{0}}Value 4: 1 byte signed1 Byte6.10 counter pulses (-128..127)CWTU
61Input b – Send value: {{0}}Value 4: 2 bytes2 Bytes7.1 pulsesCWTU
61Input b – Send value: {{0}}Value 4: 2 bytes signed2 Bytes8.1 pulses differenceCWTU
61Input b – Send value: {{0}}Value 4: 4 bytes4 Bytes12.1 counter pulses (unsigned)CWTU
61Input b – Switching sequence: {{0}}Value 4: Switch1 Bit1.1 switchCWTU
61Input b – Switching sequence: {{0}}Value 4: Percent1 Byte5.1 percentage (0..100%)CWTU
61Input b – Switching sequence: {{0}}Value 4: Byte1 Byte5.10 counter pulses (0..255)CWTU
61Input b – Switching sequence: {{0}}Value 4: Scene1 Byte18.1 scene controlCWTU
61Input b – Switching sequence: {{0}}Value 4: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
61Input b – Switching sequence: {{0}}Value 4: HVAC mode1 Byte20.102 HVAC modeCWTU
61Input b – Pulse counter 1: {{0}}Limit value reached1 Bit1.2 booleanCRT
62Input b – Blind/shutter: {{0}}Status Lower end position1 Bit1.2 booleanCWU
62Input b – Send value: {{0}}Block1 Bit1.3 enableCWTU
62Input b – Switching sequence: {{0}}Value 5: Switch1 Bit1.1 switchCWTU
62Input b – Switching sequence: {{0}}Value 5: Percent1 Byte5.1 percentage (0..100%)CWTU
62Input b – Switching sequence: {{0}}Value 5: Byte1 Byte5.10 counter pulses (0..255)CWTU
62Input b – Switching sequence: {{0}}Value 5: Scene1 Byte18.1 scene controlCWTU
62Input b – Switching sequence: {{0}}Value 5: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
62Input b – Switching sequence: {{0}}Value 5: HVAC mode1 Byte20.102 HVAC modeCWTU
62Input b – Pulse counter 2: {{0}}Counter value1 Byte6.10 counter pulses (-128..127)CRT
62Input b – Pulse counter 2: {{0}}Counter value1 Byte5.10 counter pulses (0..255)CRT
62Input b – Pulse counter 2: {{0}}Counter value2 Bytes8.1 pulses differenceCRT
62Input b – Pulse counter 2: {{0}}Counter value2 Bytes7.1 pulsesCRT
62Input b – Pulse counter 2: {{0}}Counter value4 Bytes13.1 counter pulses (signed)CRT
62Input b – Pulse counter 2: {{0}}Counter value4 Bytes12.1 counter pulses (unsigned)CRT
63Input b – Blind/shutter: {{0}}Status Move1 Bit1.2 booleanCWU
63Input b – Switching sequence: {{0}}Number of operations1 Byte5.10 counter pulses (0..255)CWTU
63Input b – Pulse counter 2: {{0}}Reset counter value1 Bit1.15 resetCW
64Input b – Blind/shutter: {{0}}Block1 Bit1.3 enableCW
64Input b – Switching sequence: {{0}}Reset switching sequence1 Bit1.17 triggerCW
64Input b – Pulse counter 2: {{0}}Request counter value1 Bit1.17 triggerCW
65Input b – Switching sequence: {{0}}Next/previous step1 Bit1.7 stepCW
65Input b – Pulse counter 2: {{0}}Limit value reached1 Bit1.2 booleanCRT
66Input b – Switching sequence: {{0}}Block1 Bit1.3 enableCW
66Input b – Pulse counter: {{0}}Block1 Bit1.3 enableCW
67Input c – Switch: {{0}}Switch1 Bit1.1 switchCWTU
67Input c+d – Switch: {{0}}Switch1 Bit1.1 switchCWTU
67Input c – Blind/shutter: {{0}}Up/down1 Bit1.8 up/downCWTU
67Input c+d – Blind/shutter: {{0}}Up/down1 Bit1.8 up/downCWTU
67Input c – Switch/dim: {{0}}Dimming4 Bit3.7 dimming controlCT
67Input c+d – Switch/dim: {{0}}Dimming4 Bit3.7 dimming controlCT
67Input c – Scene: {{0}}Scene 1…641 Byte18.1 scene controlCT
67Input c – Send value: {{0}}Value 1: Switch1 Bit1.1 switchCWTU
67Input c – Send value: {{0}}Value 1: Percent1 Byte5.1 percentage (0..100%)CWTU
67Input c – Send value: {{0}}Value 1: Forced operation2 Bit2.1 switch controlCRWT
67Input c – Send value: {{0}}Value 1: Temperature2 Bytes9.1 temperature (°C)CWTU
67Input c – Send value: {{0}}Value 1: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
67Input c – Send value: {{0}}Value 1: HVAC mode1 Byte20.102 HVAC modeCWTU
67Input c – Send value: {{0}}Value 1: 1 byte1 Byte5.10 counter pulses (0..255)CWTU
67Input c – Send value: {{0}}Value 1: 1 byte signed1 Byte6.10 counter pulses (-128..127)CWTU
67Input c – Send value: {{0}}Value 1: 2 bytes2 Bytes7.1 pulsesCWTU
67Input c – Send value: {{0}}Value 1: 2 bytes signed2 Bytes8.1 pulses differenceCWTU
67Input c – Send value: {{0}}Value 1: 4 bytes4 Bytes12.1 counter pulses (unsigned)CWTU
67Input c – Fault indicator/logic input: {{0}}Status Fault1 Bit1.11 stateCRWT
67Input c – Switching sequence: {{0}}Value 1: Switch1 Bit1.1 switchCWTU
67Input c – Switching sequence: {{0}}Value 1: Percent1 Byte5.1 percentage (0..100%)CWTU
67Input c – Switching sequence: {{0}}Value 1: Byte1 Byte5.10 counter pulses (0..255)CWTU
67Input c – Switching sequence: {{0}}Value 1: Scene1 Byte18.1 scene controlCWTU
67Input c – Switching sequence: {{0}}Value 1: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
67Input c – Switching sequence: {{0}}Value 1: HVAC mode1 Byte20.102 HVAC modeCWTU
67Input c+d – Switching sequence: {{0}}Value 1: Switch1 Bit1.1 switchCWTU
67Input c+d – Switching sequence: {{0}}Value 1: Percent1 Byte5.1 percentage (0..100%)CWTU
67Input c+d – Switching sequence: {{0}}Value 1: Byte1 Byte5.10 counter pulses (0..255)CWTU
67Input c+d – Switching sequence: {{0}}Value 1: Scene1 Byte18.1 scene controlCWTU
67Input c+d – Switching sequence: {{0}}Value 1: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
67Input c+d – Switching sequence: {{0}}Value 1: HVAC mode1 Byte20.102 HVAC modeCWTU
67Input c – Pulse counter 1: {{0}}Counter value1 Byte6.10 counter pulses (-128..127)CRT
67Input c – Pulse counter 1: {{0}}Counter value1 Byte5.10 counter pulses (0..255)CRT
67Input c – Pulse counter 1: {{0}}Counter value2 Bytes8.1 pulses differenceCRT
67Input c – Pulse counter 1: {{0}}Counter value2 Bytes7.1 pulsesCRT
67Input c – Pulse counter 1: {{0}}Counter value4 Bytes13.1 counter pulses (signed)CRT
67Input c – Pulse counter 1: {{0}}Counter value4 Bytes12.1 counter pulses (unsigned)CRT
68Input c – Switch: {{0}}Block1 Bit1.3 enableCW
68Input c+d – Switch: {{0}}Block1 Bit1.3 enableCW
68Input c – Blind/shutter: {{0}}Step/stop1 Bit1.7 stepCWTU
68Input c – Blind/shutter: {{0}}Stop1 Bit1.17 triggerCWTU
68Input c+d – Blind/shutter: {{0}}Step/stop1 Bit1.7 stepCWTU
68Input c+d – Blind/shutter: {{0}}Stop1 Bit1.17 triggerCWTU
68Input c – Switch/dim: {{0}}Switch1 Bit1.1 switchCWTU
68Input c+d – Switch/dim: {{0}}Switch1 Bit1.1 switchCWTU
68Input c – Scene: {{0}}Block1 Bit1.3 enableCW
68Input c – Send value: {{0}}Value 2: Switch1 Bit1.1 switchCWTU
68Input c – Send value: {{0}}Value 2: Percent1 Byte5.1 percentage (0..100%)CWTU
68Input c – Send value: {{0}}Value 2: Forced operation2 Bit2.1 switch controlCRWT
68Input c – Send value: {{0}}Value 2: Temperature2 Bytes9.1 temperature (°C)CWTU
68Input c – Send value: {{0}}Value 2: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
68Input c – Send value: {{0}}Value 2: HVAC mode1 Byte20.102 HVAC modeCWTU
68Input c – Send value: {{0}}Value 2: 1 byte1 Byte5.10 counter pulses (0..255)CWTU
68Input c – Send value: {{0}}Value 2: 1 byte signed1 Byte6.10 counter pulses (-128..127)CWTU
68Input c – Send value: {{0}}Value 2: 2 bytes2 Bytes7.1 pulsesCWTU
68Input c – Send value: {{0}}Value 2: 2 bytes signed2 Bytes8.1 pulses differenceCWTU
68Input c – Send value: {{0}}Value 2: 4 bytes4 Bytes12.1 counter pulses (unsigned)CWTU
68Input c – Fault indicator/logic input: {{0}}Block1 Bit1.3 enableCW
68Input c – Switching sequence: {{0}}Value 2: Switch1 Bit1.1 switchCWTU
68Input c – Switching sequence: {{0}}Value 2: Percent1 Byte5.1 percentage (0..100%)CWTU
68Input c – Switching sequence: {{0}}Value 2: Byte1 Byte5.10 counter pulses (0..255)CWTU
68Input c – Switching sequence: {{0}}Value 2: Scene1 Byte18.1 scene controlCWTU
68Input c – Switching sequence: {{0}}Value 2: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
68Input c – Switching sequence: {{0}}Value 2: HVAC mode1 Byte20.102 HVAC modeCWTU
68Input c+d – Switching sequence: {{0}}Value 2: Switch1 Bit1.1 switchCWTU
68Input c+d – Switching sequence: {{0}}Value 2: Percent1 Byte5.1 percentage (0..100%)CWTU
68Input c+d – Switching sequence: {{0}}Value 2: Byte1 Byte5.10 counter pulses (0..255)CWTU
68Input c+d – Switching sequence: {{0}}Value 2: Scene1 Byte18.1 scene controlCWTU
68Input c+d – Switching sequence: {{0}}Value 2: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
68Input c+d – Switching sequence: {{0}}Value 2: HVAC mode1 Byte20.102 HVAC modeCWTU
68Input c – Pulse counter 1: {{0}}Reset counter value1 Bit1.15 resetCW
69Input c – Switch: {{0}}Switch 21 Bit1.1 switchCWTU
69Input c+d – Blind/shutter: {{0}}Status Upper end position1 Bit1.2 booleanCWU
69Input c+d – Switch/dim: {{0}}Block1 Bit1.3 enableCW
69Input c – Send value: {{0}}Value 3: Switch1 Bit1.1 switchCWTU
69Input c – Send value: {{0}}Value 3: Percent1 Byte5.1 percentage (0..100%)CWTU
69Input c – Send value: {{0}}Value 3: Forced operation2 Bit2.1 switch controlCWTU
69Input c – Send value: {{0}}Value 3: Temperature2 Bytes9.1 temperature (°C)CWTU
69Input c – Send value: {{0}}Value 3: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
69Input c – Send value: {{0}}Value 3: HVAC mode1 Byte20.102 HVAC modeCWTU
69Input c – Send value: {{0}}Value 3: 1 byte1 Byte5.10 counter pulses (0..255)CWTU
69Input c – Send value: {{0}}Value 3: 1 byte signed1 Byte6.10 counter pulses (-128..127)CWTU
69Input c – Send value: {{0}}Value 3: 2 bytes2 Bytes7.1 pulsesCWTU
69Input c – Send value: {{0}}Value 3: 2 bytes signed2 Bytes8.1 pulses differenceCWTU
69Input c – Send value: {{0}}Value 3: 4 bytes4 Bytes12.1 counter pulses (unsigned)CWTU
69Input c – Fault indicator/logic input: {{0}}Request status Fault1 Bit1.17 triggerCW
69Input c – Switching sequence: {{0}}Value 3: Switch1 Bit1.1 switchCWTU
69Input c – Switching sequence: {{0}}Value 3: Percent1 Byte5.1 percentage (0..100%)CWTU
69Input c – Switching sequence: {{0}}Value 3: Byte1 Byte5.10 counter pulses (0..255)CWTU
69Input c – Switching sequence: {{0}}Value 3: Scene1 Byte18.1 scene controlCWTU
69Input c – Switching sequence: {{0}}Value 3: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
69Input c – Switching sequence: {{0}}Value 3: HVAC mode1 Byte20.102 HVAC modeCWTU
69Input c+d – Switching sequence: {{0}}Value 3: Switch1 Bit1.1 switchCWTU
69Input c+d – Switching sequence: {{0}}Value 3: Percent1 Byte5.1 percentage (0..100%)CWTU
69Input c+d – Switching sequence: {{0}}Value 3: Byte1 Byte5.10 counter pulses (0..255)CWTU
69Input c+d – Switching sequence: {{0}}Value 3: Scene1 Byte18.1 scene controlCWTU
69Input c+d – Switching sequence: {{0}}Value 3: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
69Input c+d – Switching sequence: {{0}}Value 3: HVAC mode1 Byte20.102 HVAC modeCWTU
69Input c – Pulse counter 1: {{0}}Request counter value1 Bit1.17 triggerCW
70Input c – Switch: {{0}}Block 21 Bit1.3 enableCW
70Input c – Blind/shutter: {{0}}Status Upper end position1 Bit1.2 booleanCWU
70Input c+d – Blind/shutter: {{0}}Status Lower end position1 Bit1.2 booleanCWU
70Input c – Switch/dim: {{0}}Block1 Bit1.3 enableCW
70Input c – Send value: {{0}}Value 4: Switch1 Bit1.1 switchCWTU
70Input c – Send value: {{0}}Value 4: Percent1 Byte5.1 percentage (0..100%)CWTU
70Input c – Send value: {{0}}Value 4: Forced operation2 Bit2.1 switch controlCWTU
70Input c – Send value: {{0}}Value 4: Temperature2 Bytes9.1 temperature (°C)CWTU
70Input c – Send value: {{0}}Value 4: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
70Input c – Send value: {{0}}Value 4: HVAC mode1 Byte20.102 HVAC modeCWTU
70Input c – Send value: {{0}}Value 4: 1 byte1 Byte5.10 counter pulses (0..255)CWTU
70Input c – Send value: {{0}}Value 4: 1 byte signed1 Byte6.10 counter pulses (-128..127)CWTU
70Input c – Send value: {{0}}Value 4: 2 bytes2 Bytes7.1 pulsesCWTU
70Input c – Send value: {{0}}Value 4: 2 bytes signed2 Bytes8.1 pulses differenceCWTU
70Input c – Send value: {{0}}Value 4: 4 bytes4 Bytes12.1 counter pulses (unsigned)CWTU
70Input c – Switching sequence: {{0}}Value 4: Switch1 Bit1.1 switchCWTU
70Input c – Switching sequence: {{0}}Value 4: Percent1 Byte5.1 percentage (0..100%)CWTU
70Input c – Switching sequence: {{0}}Value 4: Byte1 Byte5.10 counter pulses (0..255)CWTU
70Input c – Switching sequence: {{0}}Value 4: Scene1 Byte18.1 scene controlCWTU
70Input c – Switching sequence: {{0}}Value 4: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
70Input c – Switching sequence: {{0}}Value 4: HVAC mode1 Byte20.102 HVAC modeCWTU
70Input c+d – Switching sequence: {{0}}Value 4: Switch1 Bit1.1 switchCWTU
70Input c+d – Switching sequence: {{0}}Value 4: Percent1 Byte5.1 percentage (0..100%)CWTU
70Input c+d – Switching sequence: {{0}}Value 4: Byte1 Byte5.10 counter pulses (0..255)CWTU
70Input c+d – Switching sequence: {{0}}Value 4: Scene1 Byte18.1 scene controlCWTU
70Input c+d – Switching sequence: {{0}}Value 4: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
70Input c+d – Switching sequence: {{0}}Value 4: HVAC mode1 Byte20.102 HVAC modeCWTU
70Input c – Pulse counter 1: {{0}}Limit value reached1 Bit1.2 booleanCRT
71Input c – Blind/shutter: {{0}}Status Lower end position1 Bit1.2 booleanCWU
71Input c+d – Blind/shutter: {{0}}Status Move1 Bit1.2 booleanCWU
71Input c – Send value: {{0}}Block1 Bit1.3 enableCWTU
71Input c – Switching sequence: {{0}}Value 5: Switch1 Bit1.1 switchCWTU
71Input c – Switching sequence: {{0}}Value 5: Percent1 Byte5.1 percentage (0..100%)CWTU
71Input c – Switching sequence: {{0}}Value 5: Byte1 Byte5.10 counter pulses (0..255)CWTU
71Input c – Switching sequence: {{0}}Value 5: Scene1 Byte18.1 scene controlCWTU
71Input c – Switching sequence: {{0}}Value 5: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
71Input c – Switching sequence: {{0}}Value 5: HVAC mode1 Byte20.102 HVAC modeCWTU
71Input c+d – Switching sequence: {{0}}Value 5: Switch1 Bit1.1 switchCWTU
71Input c+d – Switching sequence: {{0}}Value 5: Percent1 Byte5.1 percentage (0..100%)CWTU
71Input c+d – Switching sequence: {{0}}Value 5: Byte1 Byte5.10 counter pulses (0..255)CWTU
71Input c+d – Switching sequence: {{0}}Value 5: Scene1 Byte18.1 scene controlCWTU
71Input c+d – Switching sequence: {{0}}Value 5: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
71Input c+d – Switching sequence: {{0}}Value 5: HVAC mode1 Byte20.102 HVAC modeCWTU
71Input c – Pulse counter 2: {{0}}Counter value1 Byte6.10 counter pulses (-128..127)CRT
71Input c – Pulse counter 2: {{0}}Counter value1 Byte5.10 counter pulses (0..255)CRT
71Input c – Pulse counter 2: {{0}}Counter value2 Bytes8.1 pulses differenceCRT
71Input c – Pulse counter 2: {{0}}Counter value2 Bytes7.1 pulsesCRT
71Input c – Pulse counter 2: {{0}}Counter value4 Bytes13.1 counter pulses (signed)CRT
71Input c – Pulse counter 2: {{0}}Counter value4 Bytes12.1 counter pulses (unsigned)CRT
72Input c – Blind/shutter: {{0}}Status Move1 Bit1.2 booleanCWU
72Input c+d – Blind/shutter: {{0}}Block1 Bit1.3 enableCW
72Input c – Switching sequence: {{0}}Number of operations1 Byte5.10 counter pulses (0..255)CWTU
72Input c+d – Switching sequence: {{0}}Number of operations1 Byte5.10 counter pulses (0..255)CWTU
72Input c – Pulse counter 2: {{0}}Reset counter value1 Bit1.15 resetCW
73Input c – Blind/shutter: {{0}}Block1 Bit1.3 enableCW
73Input c – Switching sequence: {{0}}Reset switching sequence1 Bit1.17 triggerCW
73Input c+d – Switching sequence: {{0}}Reset switching sequence1 Bit1.17 triggerCW
73Input c – Pulse counter 2: {{0}}Request counter value1 Bit1.17 triggerCW
74Input c – Switching sequence: {{0}}Next/previous step1 Bit1.7 stepCW
74Input c+d – Switching sequence: {{0}}Next/previous step1 Bit1.7 stepCW
74Input c – Pulse counter 2: {{0}}Limit value reached1 Bit1.2 booleanCRT
75Input c – Switching sequence: {{0}}Block1 Bit1.3 enableCW
75Input c+d – Switching sequence: {{0}}Block1 Bit1.3 enableCW
75Input c – Pulse counter: {{0}}Block1 Bit1.3 enableCW
76Input d – Switch: {{0}}Switch1 Bit1.1 switchCWTU
76Input d – Blind/shutter: {{0}}Up/down1 Bit1.8 up/downCWTU
76Input d – Switch/dim: {{0}}Dimming4 Bit3.7 dimming controlCT
76Input d – Scene: {{0}}Scene 1…641 Byte18.1 scene controlCT
76Input d – Send value: {{0}}Value 1: Switch1 Bit1.1 switchCWTU
76Input d – Send value: {{0}}Value 1: Percent1 Byte5.1 percentage (0..100%)CWTU
76Input d – Send value: {{0}}Value 1: Forced operation2 Bit2.1 switch controlCRWT
76Input d – Send value: {{0}}Value 1: Temperature2 Bytes9.1 temperature (°C)CWTU
76Input d – Send value: {{0}}Value 1: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
76Input d – Send value: {{0}}Value 1: HVAC mode1 Byte20.102 HVAC modeCWTU
76Input d – Send value: {{0}}Value 1: 1 byte1 Byte5.10 counter pulses (0..255)CWTU
76Input d – Send value: {{0}}Value 1: 1 byte signed1 Byte6.10 counter pulses (-128..127)CWTU
76Input d – Send value: {{0}}Value 1: 2 bytes2 Bytes7.1 pulsesCWTU
76Input d – Send value: {{0}}Value 1: 2 bytes signed2 Bytes8.1 pulses differenceCWTU
76Input d – Send value: {{0}}Value 1: 4 bytes4 Bytes12.1 counter pulses (unsigned)CWTU
76Input d – Fault indicator/logic input: {{0}}Status Fault1 Bit1.11 stateCRWT
76Input d – Switching sequence: {{0}}Value 1: Switch1 Bit1.1 switchCWTU
76Input d – Switching sequence: {{0}}Value 1: Percent1 Byte5.1 percentage (0..100%)CWTU
76Input d – Switching sequence: {{0}}Value 1: Byte1 Byte5.10 counter pulses (0..255)CWTU
76Input d – Switching sequence: {{0}}Value 1: Scene1 Byte18.1 scene controlCWTU
76Input d – Switching sequence: {{0}}Value 1: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
76Input d – Switching sequence: {{0}}Value 1: HVAC mode1 Byte20.102 HVAC modeCWTU
76Input d – Pulse counter 1: {{0}}Counter value1 Byte6.10 counter pulses (-128..127)CRT
76Input d – Pulse counter 1: {{0}}Counter value1 Byte5.10 counter pulses (0..255)CRT
76Input d – Pulse counter 1: {{0}}Counter value2 Bytes8.1 pulses differenceCRT
76Input d – Pulse counter 1: {{0}}Counter value2 Bytes7.1 pulsesCRT
76Input d – Pulse counter 1: {{0}}Counter value4 Bytes13.1 counter pulses (signed)CRT
76Input d – Pulse counter 1: {{0}}Counter value4 Bytes12.1 counter pulses (unsigned)CRT
77Input d – Switch: {{0}}Block1 Bit1.3 enableCW
77Input d – Blind/shutter: {{0}}Step/stop1 Bit1.7 stepCWTU
77Input d – Blind/shutter: {{0}}Stop1 Bit1.17 triggerCWTU
77Input d – Switch/dim: {{0}}Switch1 Bit1.1 switchCWTU
77Input d – Scene: {{0}}Block1 Bit1.3 enableCW
77Input d – Send value: {{0}}Value 2: Switch1 Bit1.1 switchCWTU
77Input d – Send value: {{0}}Value 2: Percent1 Byte5.1 percentage (0..100%)CWTU
77Input d – Send value: {{0}}Value 2: Forced operation2 Bit2.1 switch controlCRWT
77Input d – Send value: {{0}}Value 2: Temperature2 Bytes9.1 temperature (°C)CWTU
77Input d – Send value: {{0}}Value 2: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
77Input d – Send value: {{0}}Value 2: HVAC mode1 Byte20.102 HVAC modeCWTU
77Input d – Send value: {{0}}Value 2: 1 byte1 Byte5.10 counter pulses (0..255)CWTU
77Input d – Send value: {{0}}Value 2: 1 byte signed1 Byte6.10 counter pulses (-128..127)CWTU
77Input d – Send value: {{0}}Value 2: 2 bytes2 Bytes7.1 pulsesCWTU
77Input d – Send value: {{0}}Value 2: 2 bytes signed2 Bytes8.1 pulses differenceCWTU
77Input d – Send value: {{0}}Value 2: 4 bytes4 Bytes12.1 counter pulses (unsigned)CWTU
77Input d – Fault indicator/logic input: {{0}}Block1 Bit1.3 enableCW
77Input d – Switching sequence: {{0}}Value 2: Switch1 Bit1.1 switchCWTU
77Input d – Switching sequence: {{0}}Value 2: Percent1 Byte5.1 percentage (0..100%)CWTU
77Input d – Switching sequence: {{0}}Value 2: Byte1 Byte5.10 counter pulses (0..255)CWTU
77Input d – Switching sequence: {{0}}Value 2: Scene1 Byte18.1 scene controlCWTU
77Input d – Switching sequence: {{0}}Value 2: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
77Input d – Switching sequence: {{0}}Value 2: HVAC mode1 Byte20.102 HVAC modeCWTU
77Input d – Pulse counter 1: {{0}}Reset counter value1 Bit1.15 resetCW
78Input d – Switch: {{0}}Switch 21 Bit1.1 switchCWTU
78Input d – Send value: {{0}}Value 3: Switch1 Bit1.1 switchCWTU
78Input d – Send value: {{0}}Value 3: Percent1 Byte5.1 percentage (0..100%)CWTU
78Input d – Send value: {{0}}Value 3: Forced operation2 Bit2.1 switch controlCWTU
78Input d – Send value: {{0}}Value 3: Temperature2 Bytes9.1 temperature (°C)CWTU
78Input d – Send value: {{0}}Value 3: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
78Input d – Send value: {{0}}Value 3: HVAC mode1 Byte20.102 HVAC modeCWTU
78Input d – Send value: {{0}}Value 3: 1 byte1 Byte5.10 counter pulses (0..255)CWTU
78Input d – Send value: {{0}}Value 3: 1 byte signed1 Byte6.10 counter pulses (-128..127)CWTU
78Input d – Send value: {{0}}Value 3: 2 bytes2 Bytes7.1 pulsesCWTU
78Input d – Send value: {{0}}Value 3: 2 bytes signed2 Bytes8.1 pulses differenceCWTU
78Input d – Send value: {{0}}Value 3: 4 bytes4 Bytes12.1 counter pulses (unsigned)CWTU
78Input d – Fault indicator/logic input: {{0}}Request status Fault1 Bit1.17 triggerCW
78Input d – Switching sequence: {{0}}Value 3: Switch1 Bit1.1 switchCWTU
78Input d – Switching sequence: {{0}}Value 3: Percent1 Byte5.1 percentage (0..100%)CWTU
78Input d – Switching sequence: {{0}}Value 3: Byte1 Byte5.10 counter pulses (0..255)CWTU
78Input d – Switching sequence: {{0}}Value 3: Scene1 Byte18.1 scene controlCWTU
78Input d – Switching sequence: {{0}}Value 3: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
78Input d – Switching sequence: {{0}}Value 3: HVAC mode1 Byte20.102 HVAC modeCWTU
78Input d – Pulse counter 1: {{0}}Request counter value1 Bit1.17 triggerCW
79Input d – Switch: {{0}}Block 21 Bit1.3 enableCW
79Input d – Blind/shutter: {{0}}Status Upper end position1 Bit1.2 booleanCWU
79Input d – Switch/dim: {{0}}Block1 Bit1.3 enableCW
79Input d – Send value: {{0}}Value 4: Switch1 Bit1.1 switchCWTU
79Input d – Send value: {{0}}Value 4: Percent1 Byte5.1 percentage (0..100%)CWTU
79Input d – Send value: {{0}}Value 4: Forced operation2 Bit2.1 switch controlCWTU
79Input d – Send value: {{0}}Value 4: Temperature2 Bytes9.1 temperature (°C)CWTU
79Input d – Send value: {{0}}Value 4: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
79Input d – Send value: {{0}}Value 4: HVAC mode1 Byte20.102 HVAC modeCWTU
79Input d – Send value: {{0}}Value 4: 1 byte1 Byte5.10 counter pulses (0..255)CWTU
79Input d – Send value: {{0}}Value 4: 1 byte signed1 Byte6.10 counter pulses (-128..127)CWTU
79Input d – Send value: {{0}}Value 4: 2 bytes2 Bytes7.1 pulsesCWTU
79Input d – Send value: {{0}}Value 4: 2 bytes signed2 Bytes8.1 pulses differenceCWTU
79Input d – Send value: {{0}}Value 4: 4 bytes4 Bytes12.1 counter pulses (unsigned)CWTU
79Input d – Switching sequence: {{0}}Value 4: Switch1 Bit1.1 switchCWTU
79Input d – Switching sequence: {{0}}Value 4: Percent1 Byte5.1 percentage (0..100%)CWTU
79Input d – Switching sequence: {{0}}Value 4: Byte1 Byte5.10 counter pulses (0..255)CWTU
79Input d – Switching sequence: {{0}}Value 4: Scene1 Byte18.1 scene controlCWTU
79Input d – Switching sequence: {{0}}Value 4: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
79Input d – Switching sequence: {{0}}Value 4: HVAC mode1 Byte20.102 HVAC modeCWTU
79Input d – Pulse counter 1: {{0}}Limit value reached1 Bit1.2 booleanCRT
80Input d – Blind/shutter: {{0}}Status Lower end position1 Bit1.2 booleanCWU
80Input d – Send value: {{0}}Block1 Bit1.3 enableCWTU
80Input d – Switching sequence: {{0}}Value 5: Switch1 Bit1.1 switchCWTU
80Input d – Switching sequence: {{0}}Value 5: Percent1 Byte5.1 percentage (0..100%)CWTU
80Input d – Switching sequence: {{0}}Value 5: Byte1 Byte5.10 counter pulses (0..255)CWTU
80Input d – Switching sequence: {{0}}Value 5: Scene1 Byte18.1 scene controlCWTU
80Input d – Switching sequence: {{0}}Value 5: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
80Input d – Switching sequence: {{0}}Value 5: HVAC mode1 Byte20.102 HVAC modeCWTU
80Input d – Pulse counter 2: {{0}}Counter value1 Byte6.10 counter pulses (-128..127)CRT
80Input d – Pulse counter 2: {{0}}Counter value1 Byte5.10 counter pulses (0..255)CRT
80Input d – Pulse counter 2: {{0}}Counter value2 Bytes8.1 pulses differenceCRT
80Input d – Pulse counter 2: {{0}}Counter value2 Bytes7.1 pulsesCRT
80Input d – Pulse counter 2: {{0}}Counter value4 Bytes13.1 counter pulses (signed)CRT
80Input d – Pulse counter 2: {{0}}Counter value4 Bytes12.1 counter pulses (unsigned)CRT
81Input d – Blind/shutter: {{0}}Status Move1 Bit1.2 booleanCWU
81Input d – Switching sequence: {{0}}Number of operations1 Byte5.10 counter pulses (0..255)CWTU
81Input d – Pulse counter 2: {{0}}Reset counter value1 Bit1.15 resetCW
82Input d – Blind/shutter: {{0}}Block1 Bit1.3 enableCW
82Input d – Switching sequence: {{0}}Reset switching sequence1 Bit1.17 triggerCW
82Input d – Pulse counter 2: {{0}}Request counter value1 Bit1.17 triggerCW
83Input d – Switching sequence: {{0}}Next/previous step1 Bit1.7 stepCW
83Input d – Pulse counter 2: {{0}}Limit value reached1 Bit1.2 booleanCRT
84Input d – Switching sequence: {{0}}Block1 Bit1.3 enableCW
84Input d – Pulse counter: {{0}}Block1 Bit1.3 enableCW
85Input e – Switch: {{0}}Switch1 Bit1.1 switchCWTU
85Input e+f – Switch: {{0}}Switch1 Bit1.1 switchCWTU
85Input e – Blind/shutter: {{0}}Up/down1 Bit1.8 up/downCWTU
85Input e+f – Blind/shutter: {{0}}Up/down1 Bit1.8 up/downCWTU
85Input e – Switch/dim: {{0}}Dimming4 Bit3.7 dimming controlCT
85Input e+f – Switch/dim: {{0}}Dimming4 Bit3.7 dimming controlCT
85Input e – Scene: {{0}}Scene 1…641 Byte18.1 scene controlCT
85Input e – Send value: {{0}}Value 1: Switch1 Bit1.1 switchCWTU
85Input e – Send value: {{0}}Value 1: Percent1 Byte5.1 percentage (0..100%)CWTU
85Input e – Send value: {{0}}Value 1: Forced operation2 Bit2.1 switch controlCRWT
85Input e – Send value: {{0}}Value 1: Temperature2 Bytes9.1 temperature (°C)CWTU
85Input e – Send value: {{0}}Value 1: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
85Input e – Send value: {{0}}Value 1: HVAC mode1 Byte20.102 HVAC modeCWTU
85Input e – Send value: {{0}}Value 1: 1 byte1 Byte5.10 counter pulses (0..255)CWTU
85Input e – Send value: {{0}}Value 1: 1 byte signed1 Byte6.10 counter pulses (-128..127)CWTU
85Input e – Send value: {{0}}Value 1: 2 bytes2 Bytes7.1 pulsesCWTU
85Input e – Send value: {{0}}Value 1: 2 bytes signed2 Bytes8.1 pulses differenceCWTU
85Input e – Send value: {{0}}Value 1: 4 bytes4 Bytes12.1 counter pulses (unsigned)CWTU
85Input e – Fault indicator/logic input: {{0}}Status Fault1 Bit1.11 stateCRWT
85Input e – Switching sequence: {{0}}Value 1: Switch1 Bit1.1 switchCWTU
85Input e – Switching sequence: {{0}}Value 1: Percent1 Byte5.1 percentage (0..100%)CWTU
85Input e – Switching sequence: {{0}}Value 1: Byte1 Byte5.10 counter pulses (0..255)CWTU
85Input e – Switching sequence: {{0}}Value 1: Scene1 Byte18.1 scene controlCWTU
85Input e – Switching sequence: {{0}}Value 1: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
85Input e – Switching sequence: {{0}}Value 1: HVAC mode1 Byte20.102 HVAC modeCWTU
85Input e+f – Switching sequence: {{0}}Value 1: Switch1 Bit1.1 switchCWTU
85Input e+f – Switching sequence: {{0}}Value 1: Percent1 Byte5.1 percentage (0..100%)CWTU
85Input e+f – Switching sequence: {{0}}Value 1: Byte1 Byte5.10 counter pulses (0..255)CWTU
85Input e+f – Switching sequence: {{0}}Value 1: Scene1 Byte18.1 scene controlCWTU
85Input e+f – Switching sequence: {{0}}Value 1: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
85Input e+f – Switching sequence: {{0}}Value 1: HVAC mode1 Byte20.102 HVAC modeCWTU
85Input e – Pulse counter 1: {{0}}Counter value1 Byte6.10 counter pulses (-128..127)CRT
85Input e – Pulse counter 1: {{0}}Counter value1 Byte5.10 counter pulses (0..255)CRT
85Input e – Pulse counter 1: {{0}}Counter value2 Bytes8.1 pulses differenceCRT
85Input e – Pulse counter 1: {{0}}Counter value2 Bytes7.1 pulsesCRT
85Input e – Pulse counter 1: {{0}}Counter value4 Bytes13.1 counter pulses (signed)CRT
85Input e – Pulse counter 1: {{0}}Counter value4 Bytes12.1 counter pulses (unsigned)CRT
86Input e – Switch: {{0}}Block1 Bit1.3 enableCW
86Input e+f – Switch: {{0}}Block1 Bit1.3 enableCW
86Input e – Blind/shutter: {{0}}Step/stop1 Bit1.7 stepCWTU
86Input e – Blind/shutter: {{0}}Stop1 Bit1.17 triggerCWTU
86Input e+f – Blind/shutter: {{0}}Step/stop1 Bit1.7 stepCWTU
86Input e+f – Blind/shutter: {{0}}Stop1 Bit1.17 triggerCWTU
86Input e – Switch/dim: {{0}}Switch1 Bit1.1 switchCWTU
86Input e+f – Switch/dim: {{0}}Switch1 Bit1.1 switchCWTU
86Input e – Scene: {{0}}Block1 Bit1.3 enableCW
86Input e – Send value: {{0}}Value 2: Switch1 Bit1.1 switchCWTU
86Input e – Send value: {{0}}Value 2: Percent1 Byte5.1 percentage (0..100%)CWTU
86Input e – Send value: {{0}}Value 2: Forced operation2 Bit2.1 switch controlCRWT
86Input e – Send value: {{0}}Value 2: Temperature2 Bytes9.1 temperature (°C)CWTU
86Input e – Send value: {{0}}Value 2: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
86Input e – Send value: {{0}}Value 2: HVAC mode1 Byte20.102 HVAC modeCWTU
86Input e – Send value: {{0}}Value 2: 1 byte1 Byte5.10 counter pulses (0..255)CWTU
86Input e – Send value: {{0}}Value 2: 1 byte signed1 Byte6.10 counter pulses (-128..127)CWTU
86Input e – Send value: {{0}}Value 2: 2 bytes2 Bytes7.1 pulsesCWTU
86Input e – Send value: {{0}}Value 2: 2 bytes signed2 Bytes8.1 pulses differenceCWTU
86Input e – Send value: {{0}}Value 2: 4 bytes4 Bytes12.1 counter pulses (unsigned)CWTU
86Input e – Fault indicator/logic input: {{0}}Block1 Bit1.3 enableCW
86Input e – Switching sequence: {{0}}Value 2: Switch1 Bit1.1 switchCWTU
86Input e – Switching sequence: {{0}}Value 2: Percent1 Byte5.1 percentage (0..100%)CWTU
86Input e – Switching sequence: {{0}}Value 2: Byte1 Byte5.10 counter pulses (0..255)CWTU
86Input e – Switching sequence: {{0}}Value 2: Scene1 Byte18.1 scene controlCWTU
86Input e – Switching sequence: {{0}}Value 2: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
86Input e – Switching sequence: {{0}}Value 2: HVAC mode1 Byte20.102 HVAC modeCWTU
86Input e+f – Switching sequence: {{0}}Value 2: Switch1 Bit1.1 switchCWTU
86Input e+f – Switching sequence: {{0}}Value 2: Percent1 Byte5.1 percentage (0..100%)CWTU
86Input e+f – Switching sequence: {{0}}Value 2: Byte1 Byte5.10 counter pulses (0..255)CWTU
86Input e+f – Switching sequence: {{0}}Value 2: Scene1 Byte18.1 scene controlCWTU
86Input e+f – Switching sequence: {{0}}Value 2: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
86Input e+f – Switching sequence: {{0}}Value 2: HVAC mode1 Byte20.102 HVAC modeCWTU
86Input e – Pulse counter 1: {{0}}Reset counter value1 Bit1.15 resetCW
87Input e – Switch: {{0}}Switch 21 Bit1.1 switchCWTU
87Input e+f – Blind/shutter: {{0}}Status Upper end position1 Bit1.2 booleanCWU
87Input e+f – Switch/dim: {{0}}Block1 Bit1.3 enableCW
87Input e – Send value: {{0}}Value 3: Switch1 Bit1.1 switchCWTU
87Input e – Send value: {{0}}Value 3: Percent1 Byte5.1 percentage (0..100%)CWTU
87Input e – Send value: {{0}}Value 3: Forced operation2 Bit2.1 switch controlCWTU
87Input e – Send value: {{0}}Value 3: Temperature2 Bytes9.1 temperature (°C)CWTU
87Input e – Send value: {{0}}Value 3: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
87Input e – Send value: {{0}}Value 3: HVAC mode1 Byte20.102 HVAC modeCWTU
87Input e – Send value: {{0}}Value 3: 1 byte1 Byte5.10 counter pulses (0..255)CWTU
87Input e – Send value: {{0}}Value 3: 1 byte signed1 Byte6.10 counter pulses (-128..127)CWTU
87Input e – Send value: {{0}}Value 3: 2 bytes2 Bytes7.1 pulsesCWTU
87Input e – Send value: {{0}}Value 3: 2 bytes signed2 Bytes8.1 pulses differenceCWTU
87Input e – Send value: {{0}}Value 3: 4 bytes4 Bytes12.1 counter pulses (unsigned)CWTU
87Input e – Fault indicator/logic input: {{0}}Request status Fault1 Bit1.17 triggerCW
87Input e – Switching sequence: {{0}}Value 3: Switch1 Bit1.1 switchCWTU
87Input e – Switching sequence: {{0}}Value 3: Percent1 Byte5.1 percentage (0..100%)CWTU
87Input e – Switching sequence: {{0}}Value 3: Byte1 Byte5.10 counter pulses (0..255)CWTU
87Input e – Switching sequence: {{0}}Value 3: Scene1 Byte18.1 scene controlCWTU
87Input e – Switching sequence: {{0}}Value 3: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
87Input e – Switching sequence: {{0}}Value 3: HVAC mode1 Byte20.102 HVAC modeCWTU
87Input e+f – Switching sequence: {{0}}Value 3: Switch1 Bit1.1 switchCWTU
87Input e+f – Switching sequence: {{0}}Value 3: Percent1 Byte5.1 percentage (0..100%)CWTU
87Input e+f – Switching sequence: {{0}}Value 3: Byte1 Byte5.10 counter pulses (0..255)CWTU
87Input e+f – Switching sequence: {{0}}Value 3: Scene1 Byte18.1 scene controlCWTU
87Input e+f – Switching sequence: {{0}}Value 3: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
87Input e+f – Switching sequence: {{0}}Value 3: HVAC mode1 Byte20.102 HVAC modeCWTU
87Input e – Pulse counter 1: {{0}}Request counter value1 Bit1.17 triggerCW
88Input e – Switch: {{0}}Block 21 Bit1.3 enableCW
88Input e – Blind/shutter: {{0}}Status Upper end position1 Bit1.2 booleanCWU
88Input e+f – Blind/shutter: {{0}}Status Lower end position1 Bit1.2 booleanCWU
88Input e – Switch/dim: {{0}}Block1 Bit1.3 enableCW
88Input e – Send value: {{0}}Value 4: Switch1 Bit1.1 switchCWTU
88Input e – Send value: {{0}}Value 4: Percent1 Byte5.1 percentage (0..100%)CWTU
88Input e – Send value: {{0}}Value 4: Forced operation2 Bit2.1 switch controlCWTU
88Input e – Send value: {{0}}Value 4: Temperature2 Bytes9.1 temperature (°C)CWTU
88Input e – Send value: {{0}}Value 4: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
88Input e – Send value: {{0}}Value 4: HVAC mode1 Byte20.102 HVAC modeCWTU
88Input e – Send value: {{0}}Value 4: 1 byte1 Byte5.10 counter pulses (0..255)CWTU
88Input e – Send value: {{0}}Value 4: 1 byte signed1 Byte6.10 counter pulses (-128..127)CWTU
88Input e – Send value: {{0}}Value 4: 2 bytes2 Bytes7.1 pulsesCWTU
88Input e – Send value: {{0}}Value 4: 2 bytes signed2 Bytes8.1 pulses differenceCWTU
88Input e – Send value: {{0}}Value 4: 4 bytes4 Bytes12.1 counter pulses (unsigned)CWTU
88Input e – Switching sequence: {{0}}Value 4: Switch1 Bit1.1 switchCWTU
88Input e – Switching sequence: {{0}}Value 4: Percent1 Byte5.1 percentage (0..100%)CWTU
88Input e – Switching sequence: {{0}}Value 4: Byte1 Byte5.10 counter pulses (0..255)CWTU
88Input e – Switching sequence: {{0}}Value 4: Scene1 Byte18.1 scene controlCWTU
88Input e – Switching sequence: {{0}}Value 4: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
88Input e – Switching sequence: {{0}}Value 4: HVAC mode1 Byte20.102 HVAC modeCWTU
88Input e+f – Switching sequence: {{0}}Value 4: Switch1 Bit1.1 switchCWTU
88Input e+f – Switching sequence: {{0}}Value 4: Percent1 Byte5.1 percentage (0..100%)CWTU
88Input e+f – Switching sequence: {{0}}Value 4: Byte1 Byte5.10 counter pulses (0..255)CWTU
88Input e+f – Switching sequence: {{0}}Value 4: Scene1 Byte18.1 scene controlCWTU
88Input e+f – Switching sequence: {{0}}Value 4: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
88Input e+f – Switching sequence: {{0}}Value 4: HVAC mode1 Byte20.102 HVAC modeCWTU
88Input e – Pulse counter 1: {{0}}Limit value reached1 Bit1.2 booleanCRT
89Input e – Blind/shutter: {{0}}Status Lower end position1 Bit1.2 booleanCWU
89Input e+f – Blind/shutter: {{0}}Status Move1 Bit1.2 booleanCWU
89Input e – Send value: {{0}}Block1 Bit1.3 enableCWTU
89Input e – Switching sequence: {{0}}Value 5: Switch1 Bit1.1 switchCWTU
89Input e – Switching sequence: {{0}}Value 5: Percent1 Byte5.1 percentage (0..100%)CWTU
89Input e – Switching sequence: {{0}}Value 5: Byte1 Byte5.10 counter pulses (0..255)CWTU
89Input e – Switching sequence: {{0}}Value 5: Scene1 Byte18.1 scene controlCWTU
89Input e – Switching sequence: {{0}}Value 5: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
89Input e – Switching sequence: {{0}}Value 5: HVAC mode1 Byte20.102 HVAC modeCWTU
89Input e+f – Switching sequence: {{0}}Value 5: Switch1 Bit1.1 switchCWTU
89Input e+f – Switching sequence: {{0}}Value 5: Percent1 Byte5.1 percentage (0..100%)CWTU
89Input e+f – Switching sequence: {{0}}Value 5: Byte1 Byte5.10 counter pulses (0..255)CWTU
89Input e+f – Switching sequence: {{0}}Value 5: Scene1 Byte18.1 scene controlCWTU
89Input e+f – Switching sequence: {{0}}Value 5: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
89Input e+f – Switching sequence: {{0}}Value 5: HVAC mode1 Byte20.102 HVAC modeCWTU
89Input e – Pulse counter 2: {{0}}Counter value1 Byte6.10 counter pulses (-128..127)CRT
89Input e – Pulse counter 2: {{0}}Counter value1 Byte5.10 counter pulses (0..255)CRT
89Input e – Pulse counter 2: {{0}}Counter value2 Bytes8.1 pulses differenceCRT
89Input e – Pulse counter 2: {{0}}Counter value2 Bytes7.1 pulsesCRT
89Input e – Pulse counter 2: {{0}}Counter value4 Bytes13.1 counter pulses (signed)CRT
89Input e – Pulse counter 2: {{0}}Counter value4 Bytes12.1 counter pulses (unsigned)CRT
90Input e – Blind/shutter: {{0}}Status Move1 Bit1.2 booleanCWU
90Input e+f – Blind/shutter: {{0}}Block1 Bit1.3 enableCW
90Input e – Switching sequence: {{0}}Number of operations1 Byte5.10 counter pulses (0..255)CWTU
90Input e+f – Switching sequence: {{0}}Number of operations1 Byte5.10 counter pulses (0..255)CWTU
90Input e – Pulse counter 2: {{0}}Reset counter value1 Bit1.15 resetCW
91Input e – Blind/shutter: {{0}}Block1 Bit1.3 enableCW
91Input e – Switching sequence: {{0}}Reset switching sequence1 Bit1.17 triggerCW
91Input e+f – Switching sequence: {{0}}Reset switching sequence1 Bit1.17 triggerCW
91Input e – Pulse counter 2: {{0}}Request counter value1 Bit1.17 triggerCW
92Input e – Switching sequence: {{0}}Next/previous step1 Bit1.7 stepCW
92Input e+f – Switching sequence: {{0}}Next/previous step1 Bit1.7 stepCW
92Input e – Pulse counter 2: {{0}}Limit value reached1 Bit1.2 booleanCRT
93Input e – Switching sequence: {{0}}Block1 Bit1.3 enableCW
93Input e+f – Switching sequence: {{0}}Block1 Bit1.3 enableCW
93Input e – Pulse counter: {{0}}Block1 Bit1.3 enableCW
94Input f – Switch: {{0}}Switch1 Bit1.1 switchCWTU
94Input f – Blind/shutter: {{0}}Up/down1 Bit1.8 up/downCWTU
94Input f – Switch/dim: {{0}}Dimming4 Bit3.7 dimming controlCT
94Input f – Scene: {{0}}Scene 1…641 Byte18.1 scene controlCT
94Input f – Send value: {{0}}Value 1: Switch1 Bit1.1 switchCWTU
94Input f – Send value: {{0}}Value 1: Percent1 Byte5.1 percentage (0..100%)CWTU
94Input f – Send value: {{0}}Value 1: Forced operation2 Bit2.1 switch controlCRWT
94Input f – Send value: {{0}}Value 1: Temperature2 Bytes9.1 temperature (°C)CWTU
94Input f – Send value: {{0}}Value 1: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
94Input f – Send value: {{0}}Value 1: HVAC mode1 Byte20.102 HVAC modeCWTU
94Input f – Send value: {{0}}Value 1: 1 byte1 Byte5.10 counter pulses (0..255)CWTU
94Input f – Send value: {{0}}Value 1: 1 byte signed1 Byte6.10 counter pulses (-128..127)CWTU
94Input f – Send value: {{0}}Value 1: 2 bytes2 Bytes7.1 pulsesCWTU
94Input f – Send value: {{0}}Value 1: 2 bytes signed2 Bytes8.1 pulses differenceCWTU
94Input f – Send value: {{0}}Value 1: 4 bytes4 Bytes12.1 counter pulses (unsigned)CWTU
94Input f – Fault indicator/logic input: {{0}}Status Fault1 Bit1.11 stateCRWT
94Input f – Switching sequence: {{0}}Value 1: Switch1 Bit1.1 switchCWTU
94Input f – Switching sequence: {{0}}Value 1: Percent1 Byte5.1 percentage (0..100%)CWTU
94Input f – Switching sequence: {{0}}Value 1: Byte1 Byte5.10 counter pulses (0..255)CWTU
94Input f – Switching sequence: {{0}}Value 1: Scene1 Byte18.1 scene controlCWTU
94Input f – Switching sequence: {{0}}Value 1: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
94Input f – Switching sequence: {{0}}Value 1: HVAC mode1 Byte20.102 HVAC modeCWTU
94Input f – Pulse counter 1: {{0}}Counter value1 Byte6.10 counter pulses (-128..127)CRT
94Input f – Pulse counter 1: {{0}}Counter value1 Byte5.10 counter pulses (0..255)CRT
94Input f – Pulse counter 1: {{0}}Counter value2 Bytes8.1 pulses differenceCRT
94Input f – Pulse counter 1: {{0}}Counter value2 Bytes7.1 pulsesCRT
94Input f – Pulse counter 1: {{0}}Counter value4 Bytes13.1 counter pulses (signed)CRT
94Input f – Pulse counter 1: {{0}}Counter value4 Bytes12.1 counter pulses (unsigned)CRT
95Input f – Switch: {{0}}Block1 Bit1.3 enableCW
95Input f – Blind/shutter: {{0}}Step/stop1 Bit1.7 stepCWTU
95Input f – Blind/shutter: {{0}}Stop1 Bit1.17 triggerCWTU
95Input f – Switch/dim: {{0}}Switch1 Bit1.1 switchCWTU
95Input f – Scene: {{0}}Block1 Bit1.3 enableCW
95Input f – Send value: {{0}}Value 2: Switch1 Bit1.1 switchCWTU
95Input f – Send value: {{0}}Value 2: Percent1 Byte5.1 percentage (0..100%)CWTU
95Input f – Send value: {{0}}Value 2: Forced operation2 Bit2.1 switch controlCRWT
95Input f – Send value: {{0}}Value 2: Temperature2 Bytes9.1 temperature (°C)CWTU
95Input f – Send value: {{0}}Value 2: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
95Input f – Send value: {{0}}Value 2: HVAC mode1 Byte20.102 HVAC modeCWTU
95Input f – Send value: {{0}}Value 2: 1 byte1 Byte5.10 counter pulses (0..255)CWTU
95Input f – Send value: {{0}}Value 2: 1 byte signed1 Byte6.10 counter pulses (-128..127)CWTU
95Input f – Send value: {{0}}Value 2: 2 bytes2 Bytes7.1 pulsesCWTU
95Input f – Send value: {{0}}Value 2: 2 bytes signed2 Bytes8.1 pulses differenceCWTU
95Input f – Send value: {{0}}Value 2: 4 bytes4 Bytes12.1 counter pulses (unsigned)CWTU
95Input f – Fault indicator/logic input: {{0}}Block1 Bit1.3 enableCW
95Input f – Switching sequence: {{0}}Value 2: Switch1 Bit1.1 switchCWTU
95Input f – Switching sequence: {{0}}Value 2: Percent1 Byte5.1 percentage (0..100%)CWTU
95Input f – Switching sequence: {{0}}Value 2: Byte1 Byte5.10 counter pulses (0..255)CWTU
95Input f – Switching sequence: {{0}}Value 2: Scene1 Byte18.1 scene controlCWTU
95Input f – Switching sequence: {{0}}Value 2: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
95Input f – Switching sequence: {{0}}Value 2: HVAC mode1 Byte20.102 HVAC modeCWTU
95Input f – Pulse counter 1: {{0}}Reset counter value1 Bit1.15 resetCW
96Input f – Switch: {{0}}Switch 21 Bit1.1 switchCWTU
96Input f – Send value: {{0}}Value 3: Switch1 Bit1.1 switchCWTU
96Input f – Send value: {{0}}Value 3: Percent1 Byte5.1 percentage (0..100%)CWTU
96Input f – Send value: {{0}}Value 3: Forced operation2 Bit2.1 switch controlCWTU
96Input f – Send value: {{0}}Value 3: Temperature2 Bytes9.1 temperature (°C)CWTU
96Input f – Send value: {{0}}Value 3: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
96Input f – Send value: {{0}}Value 3: HVAC mode1 Byte20.102 HVAC modeCWTU
96Input f – Send value: {{0}}Value 3: 1 byte1 Byte5.10 counter pulses (0..255)CWTU
96Input f – Send value: {{0}}Value 3: 1 byte signed1 Byte6.10 counter pulses (-128..127)CWTU
96Input f – Send value: {{0}}Value 3: 2 bytes2 Bytes7.1 pulsesCWTU
96Input f – Send value: {{0}}Value 3: 2 bytes signed2 Bytes8.1 pulses differenceCWTU
96Input f – Send value: {{0}}Value 3: 4 bytes4 Bytes12.1 counter pulses (unsigned)CWTU
96Input f – Fault indicator/logic input: {{0}}Request status Fault1 Bit1.17 triggerCW
96Input f – Switching sequence: {{0}}Value 3: Switch1 Bit1.1 switchCWTU
96Input f – Switching sequence: {{0}}Value 3: Percent1 Byte5.1 percentage (0..100%)CWTU
96Input f – Switching sequence: {{0}}Value 3: Byte1 Byte5.10 counter pulses (0..255)CWTU
96Input f – Switching sequence: {{0}}Value 3: Scene1 Byte18.1 scene controlCWTU
96Input f – Switching sequence: {{0}}Value 3: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
96Input f – Switching sequence: {{0}}Value 3: HVAC mode1 Byte20.102 HVAC modeCWTU
96Input f – Pulse counter 1: {{0}}Request counter value1 Bit1.17 triggerCW
97Input f – Switch: {{0}}Block 21 Bit1.3 enableCW
97Input f – Blind/shutter: {{0}}Status Upper end position1 Bit1.2 booleanCWU
97Input f – Switch/dim: {{0}}Block1 Bit1.3 enableCW
97Input f – Send value: {{0}}Value 4: Switch1 Bit1.1 switchCWTU
97Input f – Send value: {{0}}Value 4: Percent1 Byte5.1 percentage (0..100%)CWTU
97Input f – Send value: {{0}}Value 4: Forced operation2 Bit2.1 switch controlCWTU
97Input f – Send value: {{0}}Value 4: Temperature2 Bytes9.1 temperature (°C)CWTU
97Input f – Send value: {{0}}Value 4: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
97Input f – Send value: {{0}}Value 4: HVAC mode1 Byte20.102 HVAC modeCWTU
97Input f – Send value: {{0}}Value 4: 1 byte1 Byte5.10 counter pulses (0..255)CWTU
97Input f – Send value: {{0}}Value 4: 1 byte signed1 Byte6.10 counter pulses (-128..127)CWTU
97Input f – Send value: {{0}}Value 4: 2 bytes2 Bytes7.1 pulsesCWTU
97Input f – Send value: {{0}}Value 4: 2 bytes signed2 Bytes8.1 pulses differenceCWTU
97Input f – Send value: {{0}}Value 4: 4 bytes4 Bytes12.1 counter pulses (unsigned)CWTU
97Input f – Switching sequence: {{0}}Value 4: Switch1 Bit1.1 switchCWTU
97Input f – Switching sequence: {{0}}Value 4: Percent1 Byte5.1 percentage (0..100%)CWTU
97Input f – Switching sequence: {{0}}Value 4: Byte1 Byte5.10 counter pulses (0..255)CWTU
97Input f – Switching sequence: {{0}}Value 4: Scene1 Byte18.1 scene controlCWTU
97Input f – Switching sequence: {{0}}Value 4: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
97Input f – Switching sequence: {{0}}Value 4: HVAC mode1 Byte20.102 HVAC modeCWTU
97Input f – Pulse counter 1: {{0}}Limit value reached1 Bit1.2 booleanCRT
98Input f – Blind/shutter: {{0}}Status Lower end position1 Bit1.2 booleanCWU
98Input f – Send value: {{0}}Block1 Bit1.3 enableCWTU
98Input f – Switching sequence: {{0}}Value 5: Switch1 Bit1.1 switchCWTU
98Input f – Switching sequence: {{0}}Value 5: Percent1 Byte5.1 percentage (0..100%)CWTU
98Input f – Switching sequence: {{0}}Value 5: Byte1 Byte5.10 counter pulses (0..255)CWTU
98Input f – Switching sequence: {{0}}Value 5: Scene1 Byte18.1 scene controlCWTU
98Input f – Switching sequence: {{0}}Value 5: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
98Input f – Switching sequence: {{0}}Value 5: HVAC mode1 Byte20.102 HVAC modeCWTU
98Input f – Pulse counter 2: {{0}}Counter value1 Byte6.10 counter pulses (-128..127)CRT
98Input f – Pulse counter 2: {{0}}Counter value1 Byte5.10 counter pulses (0..255)CRT
98Input f – Pulse counter 2: {{0}}Counter value2 Bytes8.1 pulses differenceCRT
98Input f – Pulse counter 2: {{0}}Counter value2 Bytes7.1 pulsesCRT
98Input f – Pulse counter 2: {{0}}Counter value4 Bytes13.1 counter pulses (signed)CRT
98Input f – Pulse counter 2: {{0}}Counter value4 Bytes12.1 counter pulses (unsigned)CRT
99Input f – Blind/shutter: {{0}}Status Move1 Bit1.2 booleanCWU
99Input f – Switching sequence: {{0}}Number of operations1 Byte5.10 counter pulses (0..255)CWTU
99Input f – Pulse counter 2: {{0}}Reset counter value1 Bit1.15 resetCW
100Input f – Blind/shutter: {{0}}Block1 Bit1.3 enableCW
100Input f – Switching sequence: {{0}}Reset switching sequence1 Bit1.17 triggerCW
100Input f – Pulse counter 2: {{0}}Request counter value1 Bit1.17 triggerCW
101Input f – Switching sequence: {{0}}Next/previous step1 Bit1.7 stepCW
101Input f – Pulse counter 2: {{0}}Limit value reached1 Bit1.2 booleanCRT
102Input f – Switching sequence: {{0}}Block1 Bit1.3 enableCW
102Input f – Pulse counter: {{0}}Block1 Bit1.3 enableCW
103Input g – Switch: {{0}}Switch1 Bit1.1 switchCWTU
103Input g+h – Switch: {{0}}Switch1 Bit1.1 switchCWTU
103Input g – Blind/shutter: {{0}}Up/down1 Bit1.8 up/downCWTU
103Input g+h – Blind/shutter: {{0}}Up/down1 Bit1.8 up/downCWTU
103Input g – Switch/dim: {{0}}Dimming4 Bit3.7 dimming controlCT
103Input g+h – Switch/dim: {{0}}Dimming4 Bit3.7 dimming controlCT
103Input g – Scene: {{0}}Scene 1…641 Byte18.1 scene controlCT
103Input g – Send value: {{0}}Value 1: Switch1 Bit1.1 switchCWTU
103Input g – Send value: {{0}}Value 1: Percent1 Byte5.1 percentage (0..100%)CWTU
103Input g – Send value: {{0}}Value 1: Forced operation2 Bit2.1 switch controlCRWT
103Input g – Send value: {{0}}Value 1: Temperature2 Bytes9.1 temperature (°C)CWTU
103Input g – Send value: {{0}}Value 1: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
103Input g – Send value: {{0}}Value 1: HVAC mode1 Byte20.102 HVAC modeCWTU
103Input g – Send value: {{0}}Value 1: 1 byte1 Byte5.10 counter pulses (0..255)CWTU
103Input g – Send value: {{0}}Value 1: 1 byte signed1 Byte6.10 counter pulses (-128..127)CWTU
103Input g – Send value: {{0}}Value 1: 2 bytes2 Bytes7.1 pulsesCWTU
103Input g – Send value: {{0}}Value 1: 2 bytes signed2 Bytes8.1 pulses differenceCWTU
103Input g – Send value: {{0}}Value 1: 4 bytes4 Bytes12.1 counter pulses (unsigned)CWTU
103Input g – Fault indicator/logic input: {{0}}Status Fault1 Bit1.11 stateCRWT
103Input g – Switching sequence: {{0}}Value 1: Switch1 Bit1.1 switchCWTU
103Input g – Switching sequence: {{0}}Value 1: Percent1 Byte5.1 percentage (0..100%)CWTU
103Input g – Switching sequence: {{0}}Value 1: Byte1 Byte5.10 counter pulses (0..255)CWTU
103Input g – Switching sequence: {{0}}Value 1: Scene1 Byte18.1 scene controlCWTU
103Input g – Switching sequence: {{0}}Value 1: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
103Input g – Switching sequence: {{0}}Value 1: HVAC mode1 Byte20.102 HVAC modeCWTU
103Input g+h – Switching sequence: {{0}}Value 1: Switch1 Bit1.1 switchCWTU
103Input g+h – Switching sequence: {{0}}Value 1: Percent1 Byte5.1 percentage (0..100%)CWTU
103Input g+h – Switching sequence: {{0}}Value 1: Byte1 Byte5.10 counter pulses (0..255)CWTU
103Input g+h – Switching sequence: {{0}}Value 1: Scene1 Byte18.1 scene controlCWTU
103Input g+h – Switching sequence: {{0}}Value 1: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
103Input g+h – Switching sequence: {{0}}Value 1: HVAC mode1 Byte20.102 HVAC modeCWTU
103Input g – Pulse counter 1: {{0}}Counter value1 Byte6.10 counter pulses (-128..127)CRT
103Input g – Pulse counter 1: {{0}}Counter value1 Byte5.10 counter pulses (0..255)CRT
103Input g – Pulse counter 1: {{0}}Counter value2 Bytes8.1 pulses differenceCRT
103Input g – Pulse counter 1: {{0}}Counter value2 Bytes7.1 pulsesCRT
103Input g – Pulse counter 1: {{0}}Counter value4 Bytes13.1 counter pulses (signed)CRT
103Input g – Pulse counter 1: {{0}}Counter value4 Bytes12.1 counter pulses (unsigned)CRT
104Input g – Switch: {{0}}Block1 Bit1.3 enableCW
104Input g+h – Switch: {{0}}Block1 Bit1.3 enableCW
104Input g – Blind/shutter: {{0}}Step/stop1 Bit1.7 stepCWTU
104Input g – Blind/shutter: {{0}}Stop1 Bit1.17 triggerCWTU
104Input g+h – Blind/shutter: {{0}}Step/stop1 Bit1.7 stepCWTU
104Input g+h – Blind/shutter: {{0}}Stop1 Bit1.17 triggerCWTU
104Input g – Switch/dim: {{0}}Switch1 Bit1.1 switchCWTU
104Input g+h – Switch/dim: {{0}}Switch1 Bit1.1 switchCWTU
104Input g – Scene: {{0}}Block1 Bit1.3 enableCW
104Input g – Send value: {{0}}Value 2: Switch1 Bit1.1 switchCWTU
104Input g – Send value: {{0}}Value 2: Percent1 Byte5.1 percentage (0..100%)CWTU
104Input g – Send value: {{0}}Value 2: Forced operation2 Bit2.1 switch controlCRWT
104Input g – Send value: {{0}}Value 2: Temperature2 Bytes9.1 temperature (°C)CWTU
104Input g – Send value: {{0}}Value 2: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
104Input g – Send value: {{0}}Value 2: HVAC mode1 Byte20.102 HVAC modeCWTU
104Input g – Send value: {{0}}Value 2: 1 byte1 Byte5.10 counter pulses (0..255)CWTU
104Input g – Send value: {{0}}Value 2: 1 byte signed1 Byte6.10 counter pulses (-128..127)CWTU
104Input g – Send value: {{0}}Value 2: 2 bytes2 Bytes7.1 pulsesCWTU
104Input g – Send value: {{0}}Value 2: 2 bytes signed2 Bytes8.1 pulses differenceCWTU
104Input g – Send value: {{0}}Value 2: 4 bytes4 Bytes12.1 counter pulses (unsigned)CWTU
104Input g – Fault indicator/logic input: {{0}}Block1 Bit1.3 enableCW
104Input g – Switching sequence: {{0}}Value 2: Switch1 Bit1.1 switchCWTU
104Input g – Switching sequence: {{0}}Value 2: Percent1 Byte5.1 percentage (0..100%)CWTU
104Input g – Switching sequence: {{0}}Value 2: Byte1 Byte5.10 counter pulses (0..255)CWTU
104Input g – Switching sequence: {{0}}Value 2: Scene1 Byte18.1 scene controlCWTU
104Input g – Switching sequence: {{0}}Value 2: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
104Input g – Switching sequence: {{0}}Value 2: HVAC mode1 Byte20.102 HVAC modeCWTU
104Input g+h – Switching sequence: {{0}}Value 2: Switch1 Bit1.1 switchCWTU
104Input g+h – Switching sequence: {{0}}Value 2: Percent1 Byte5.1 percentage (0..100%)CWTU
104Input g+h – Switching sequence: {{0}}Value 2: Byte1 Byte5.10 counter pulses (0..255)CWTU
104Input g+h – Switching sequence: {{0}}Value 2: Scene1 Byte18.1 scene controlCWTU
104Input g+h – Switching sequence: {{0}}Value 2: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
104Input g+h – Switching sequence: {{0}}Value 2: HVAC mode1 Byte20.102 HVAC modeCWTU
104Input g – Pulse counter 1: {{0}}Reset counter value1 Bit1.15 resetCW
105Input g – Switch: {{0}}Switch 21 Bit1.1 switchCWTU
105Input g+h – Blind/shutter: {{0}}Status Upper end position1 Bit1.2 booleanCWU
105Input g+h – Switch/dim: {{0}}Block1 Bit1.3 enableCW
105Input g – Send value: {{0}}Value 3: Switch1 Bit1.1 switchCWTU
105Input g – Send value: {{0}}Value 3: Percent1 Byte5.1 percentage (0..100%)CWTU
105Input g – Send value: {{0}}Value 3: Forced operation2 Bit2.1 switch controlCWTU
105Input g – Send value: {{0}}Value 3: Temperature2 Bytes9.1 temperature (°C)CWTU
105Input g – Send value: {{0}}Value 3: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
105Input g – Send value: {{0}}Value 3: HVAC mode1 Byte20.102 HVAC modeCWTU
105Input g – Send value: {{0}}Value 3: 1 byte1 Byte5.10 counter pulses (0..255)CWTU
105Input g – Send value: {{0}}Value 3: 1 byte signed1 Byte6.10 counter pulses (-128..127)CWTU
105Input g – Send value: {{0}}Value 3: 2 bytes2 Bytes7.1 pulsesCWTU
105Input g – Send value: {{0}}Value 3: 2 bytes signed2 Bytes8.1 pulses differenceCWTU
105Input g – Send value: {{0}}Value 3: 4 bytes4 Bytes12.1 counter pulses (unsigned)CWTU
105Input g – Fault indicator/logic input: {{0}}Request status Fault1 Bit1.17 triggerCW
105Input g – Switching sequence: {{0}}Value 3: Switch1 Bit1.1 switchCWTU
105Input g – Switching sequence: {{0}}Value 3: Percent1 Byte5.1 percentage (0..100%)CWTU
105Input g – Switching sequence: {{0}}Value 3: Byte1 Byte5.10 counter pulses (0..255)CWTU
105Input g – Switching sequence: {{0}}Value 3: Scene1 Byte18.1 scene controlCWTU
105Input g – Switching sequence: {{0}}Value 3: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
105Input g – Switching sequence: {{0}}Value 3: HVAC mode1 Byte20.102 HVAC modeCWTU
105Input g+h – Switching sequence: {{0}}Value 3: Switch1 Bit1.1 switchCWTU
105Input g+h – Switching sequence: {{0}}Value 3: Percent1 Byte5.1 percentage (0..100%)CWTU
105Input g+h – Switching sequence: {{0}}Value 3: Byte1 Byte5.10 counter pulses (0..255)CWTU
105Input g+h – Switching sequence: {{0}}Value 3: Scene1 Byte18.1 scene controlCWTU
105Input g+h – Switching sequence: {{0}}Value 3: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
105Input g+h – Switching sequence: {{0}}Value 3: HVAC mode1 Byte20.102 HVAC modeCWTU
105Input g – Pulse counter 1: {{0}}Request counter value1 Bit1.17 triggerCW
106Input g – Switch: {{0}}Block 21 Bit1.3 enableCW
106Input g – Blind/shutter: {{0}}Status Upper end position1 Bit1.2 booleanCWU
106Input g+h – Blind/shutter: {{0}}Status Lower end position1 Bit1.2 booleanCWU
106Input g – Switch/dim: {{0}}Block1 Bit1.3 enableCW
106Input g – Send value: {{0}}Value 4: Switch1 Bit1.1 switchCWTU
106Input g – Send value: {{0}}Value 4: Percent1 Byte5.1 percentage (0..100%)CWTU
106Input g – Send value: {{0}}Value 4: Forced operation2 Bit2.1 switch controlCWTU
106Input g – Send value: {{0}}Value 4: Temperature2 Bytes9.1 temperature (°C)CWTU
106Input g – Send value: {{0}}Value 4: Color3 Bytes232.600 RGB value 3x(0..255)CWTU
106Input g – Send value: {{0}}Value 4: HVAC mode1 Byte20.102 HVAC modeCWTU
106Input g – Send value: {{0}}Value 4: 1 byte1 Byte5.10 counter pulses (0..255)CWTU
106Input g – Send value: {{0}}Value 4: 1 byte signed1 Byte6.10 counter pulses (-128..127)CWTU
106Input g – Send value: {{0}}Value 4: 2 bytes2 Bytes7.1 pulsesCWTU

First 1000 of 1168 group objects shown. Download the .knxprod for the full list.

Parameters (334)
ParameterTypeDefault
DevicelistBES
Signal typelistEXTERNAL
Number of inputsunsignedInt 4…168
Enable templatesunsignedInt 0…11
CalcParamunsignedInt 0…2550
Manual operationunsignedInt 0…11
Logic 1-4unsignedInt 0…11
Logic 5-8unsignedInt 0…11
Logic 9-12unsignedInt 0…10
Logic 13-16unsignedInt 0…10
1#Device settings$CentralunsignedInt 0…2550
2#Manual operation$CentralunsignedInt 0…2550
3#Logic$LogicunsignedInt 0…2550
4#TemplatesunsignedInt 0…2550
5#Input a||Input a+b$Input aunsignedInt 0…2550
6#Input b$Input bunsignedInt 0…2550
7#Input c||Input c+d$Input cunsignedInt 0…2550
8#Input d$Input dunsignedInt 0…2550
9#Input e||Input e+f$Input eunsignedInt 0…2550
10#Input f$Input funsignedInt 0…2550
11#Input g||Input g+h$Input gunsignedInt 0…2550
12#Input h$Input hunsignedInt 0…2550
UCC_ENDunsignedInt 0…65535404
ApplicationlistDevice
Parameter SizeunsignedInt 0…655358
Sending delay after KNX voltage recoveryunsignedInt 2…602
Telegram rate limitunsignedInt 0…10
Maximum number of sent telegramsunsignedInt 0…10020
In periodunsignedInt 0…591
Access to i-bus ToollistFull access
Enable Group Object "In operation"listNo
Sending cycletime600
Enable Time Group Objects for setting of device timelistNo
Request Date/Time via Group ObjectunsignedInt 0…10
Config lengthunsignedInt 0…655350
ApplicationlistManualControl
Parameter SizeunsignedInt 0…655353
Enable manual operationunsignedInt 0…11
Automatic reset from manual operation to KNX operationunsignedInt 0…11
Automatic reset aftertime300
State after end of manual operationlistRefreshed KNX state
Config lengthunsignedInt 0…655353
ConfigunsignedInt 0…1677721532776
ApplicationlistLogic
Parameter SizeunsignedInt 0…6553540
Logic functionlistNone
Connection AlistDeactivated
Default setting "Connection A"listRead value
Connection BlistDeactivated
Default setting "Connection B"listRead value
Input alistApply value
Input blistApply value
Input clistDeactivated
Input dlistDeactivated
Input elistDeactivated
Input flistDeactivated
Input glistDeactivated
Input hlistDeactivated
Block logiclistDeactivated
State after ETS download or KNX voltage recoverylistLast state
Invert resultunsignedInt 0…10
Send "Status Result"listOn change
ApplicationlistSwitch template
Parameter SizeunsignedInt 0…6553529
DevicelistFTS
DevicelistUSU
Descriptiontext
Templates activatedunsignedInt 0…11
Templates activatedunsignedInt 0…10
Parameter settingunsignedInt 0…10
Distinction between short and long operationunsignedInt 0…10
Reaction on short operationlistOn
Reaction on long operationlistOff
Reaction on opening the contactlistOff
Reaction on closing the contactlistOn
Reaction when touchedlistToggle
Reaction on releaselistNo reaction
Send input status after ETS download or KNX voltage recoveryunsignedInt 0…10
Extended settingsunsignedInt 0…10
Enable function "Switch 2"unsignedInt 0…10
Enable function Switch 2unsignedInt 0…10
FunctionCodelistDIOCONF_PUSH_BUTTON_SENSOR
Contact typelistNO contact
Long operation aftertime400
Long operation afterunsignedInt 0…65535400
Signal typelistAutomatic
Interference suppression filterunsignedInt 12…15030
Interference suppression filterunsignedInt 60…15060
Block inputlistDeactivated
Block operating arealistDeactivated
Input buttonlistPush button reaction
Config lengthunsignedInt 0…6553515
ConfigunsignedInt 0…42949672950
ApplicationlistSwitch (2-button) template
Parameter SizeunsignedInt 0…6553527
Reaction on operationlistOn
Reaction on operationlistOff
Reaction on operationlistToggle
FunctionCodelistDIOCONF_PUSH_BUTTON_2_BUTTON_SENSOR
ConfigunsignedInt 0…655350
ApplicationlistBlind/shutter template
Operating modelistBlind
Blind operationlistShort: step/stop, long: move
Shutter operationlistShort: stop, long: move
Stop movementlistOn release
Cycle for sending the step/stop telegramtime500
Cycle for sending the Step/Stop telegramunsignedInt 0…65535500
"Movement" direction change aftertime0
"Slat" direction change aftertime5000
ApplicationlistBlind/shutter (2-button) template
Parameter SizeunsignedInt 0…6553532
Direction of movementlistUp
Direction of movementlistDown
ApplicationlistSwitch/dim template
On short operationlistToggle
On long operationlistChange dimming direction, darker when On
Dimming methodlistStart-stop-dimming
Dimming processlistStart-stop-dimming
Change per steplist3 %
Telegram is repeated everytime600
Telegram is repeated everyunsignedInt 0…65535600
ApplicationlistSwitch/dim (2-button) template
Parameter SizeunsignedInt 0…6553533
On short operationlistOn
On long operationlistBrighter
On short operationlistOff
On long operationlistDarker
ApplicationlistScenes template
Distinction between short and long operationunsignedInt 0…11
Scene numberunsignedInt 1…641
On short operation: Scene numberunsignedInt 1…641
ScenelistSend
Reaction on long operationlistSave scene
On long operation: Scene numberunsignedInt 1…641
Long operation aftertime3000
Long operation afterunsignedInt 0…655353000
ApplicationlistSend value/multiple operation template
Parameter SizeunsignedInt 0…6553556
Send value onlist1-fold operation
Toggle valueunsignedInt 0…10
Maximum time between two operationstime500
Maximum time between two operationsunsignedInt 0…65535500
Send values on every operationunsignedInt 0…10
On change of contact: DPTlistSwitch [DPT 1.001]
OperationlistClose
OperationlistToggle
There is text in the "Default value" columnlistShort operation
There is text in the "Default value" columnlist1-fold operation
On short operation: DPTlistSwitch [DPT 1.001]
On 1-fold operation: DPTlistSwitch [DPT 1.001]
Value 1 of Group Object "Value 1: Switch"listOn
Value 1 of Group Object "Value 1: Switch"listToggle
Value of Group Object "Value 1: Percent"unsignedInt 0…1000
Value of Group Object "Value 1: Percent"unsignedInt 0…2550
Value of Group Object "Value 1: Forced operation"listForced operation, value 1
Value of Group Object "Value 1: Temperature"signedInt -100…25020
Value of Group Object "Value 1: Temperature"signedInt -32768…327672000
Value of Group Object "Value 1: Color"color#000000
Value of Group Object "Value 1: HVAC mode"listAutomatic
Value of Group Object "Value 1: 1 byte"unsignedInt 0…2550
Value of Group Object "Value 1: 1 byte signed"signedInt -128…1270
Value of Group Object "Value 1: 2 bytes"unsignedInt 0…655350
Value of Group Object "Value 1: 2 bytes signed"signedInt -32768…327670
Value of Group Object "Value 1: 4 bytes"unsignedInt 0…42949672950
Value of Group Object "Value 3: Percent"unsignedInt 0…1000
Value of Group Object "Value 3: Percent"unsignedInt 0…2550
Value of Group Object "Value 3: Forced operation"listNo forced operation
Value of Group Object "Value 3: Temperature"signedInt -100…25020
Value of Group Object "Value 3: Temperature"signedInt -32768…327672000
Value of Group Object "Value 3: Color"color#000000
Value of Group Object "Value 3: HVAC mode"listAutomatic
Value of Group Object "Value 3: 1 byte"unsignedInt 0…2550
Value of Group Object "Value 3: 1 byte signed"signedInt -128…1270
Value of Group Object "Value 3: 2 bytes"unsignedInt 0…655350
Value of Group Object "Value 3: 2 bytes signed"signedInt -32768…327670
Value of Group Object "Value 3: 4 bytes"unsignedInt 0…42949672950
There is text in the "Default value" columnlistLong operation
There is text in the "Default value" columnlist2-fold operation
OperationlistNo reaction
On long operation: DPTlistSwitch [DPT 1.001]
On 2-fold operation: DPTlistSwitch [DPT 1.001]
Value 2 of Group Object "Value 1: Switch"listOff
Value 2 of Group Object "Value 1: Switch"listToggle
Value of Group Object "Value 2: Percent"unsignedInt 0…1000
Value of Group Object "Value 2: Percent"unsignedInt 0…2550
Value of Group Object "Value 2: Forced operation"listForced operation, value 0
Value of Group Object "Value 2: Temperature"signedInt -100…25020
Value of Group Object "Value 2: Temperature"signedInt -32768…327672000
Value of Group Object "Value 2: Color"color#000000
Value of Group Object "Value 2: HVAC mode"listAutomatic
Value of Group Object "Value 2: 1 byte"unsignedInt 0…2550
Value of Group Object "Value 2: 1 byte signed"signedInt -128…1270
Value of Group Object "Value 2: 2 bytes"unsignedInt 0…655350
Value of Group Object "Value 2: 2 bytes signed"signedInt -32768…327670
Value of Group Object "Value 2: 4 bytes"unsignedInt 0…42949672950
Value of Group Object "Value 4: Percent"unsignedInt 0…1000
Value of Group Object "Value 4: Percent"unsignedInt 0…2550
Value of Group Object "Value 4: Forced operation"listNo forced operation
Value of Group Object "Value 4: Temperature"signedInt -100…25020
Value of Group Object "Value 4: Temperature"signedInt -32768…327672000
Value of Group Object "Value 4: Color"color#000000
Value of Group Object "Value 4: HVAC mode"listAutomatic
Value of Group Object "Value 4: 1 byte"unsignedInt 0…2550
Value of Group Object "Value 4: 1 byte signed"signedInt -128…1270
Value of Group Object "Value 4: 2 bytes"unsignedInt 0…655350
Value of Group Object "Value 4: 2 bytes signed"signedInt -32768…327670
Value of Group Object "Value 4: 4 bytes"unsignedInt 0…42949672950
There is text in the "Default value" columnlist3-fold operation
On 3-fold operation: DPTlistDeactivated
Value of Group Object "Value 3: Switch"listOff
Long operationlistLong operation
On long operation: DPTlistDeactivated
Value of Group Object "Value 4: Switch"listOn
Activate minimum signal durationunsignedInt 0…10
On opening the contacttime1000
On closing the contacttime1000
Input buttonlistSwitching reaction
ApplicationlistFault indicator/logic Input template
Send value of Group Object "Status Fault"listOn change
Sending cycletime30
On Group Object valuelist0 or 1
Send "Status Fault" after ETS download or KNX voltage recoveryunsignedInt 0…10
Input buttonlistBlocked
ApplicationlistSwitching sequence template
Parameter SizeunsignedInt 0…65535131
App_2ButtonunsignedInt 0…10
FunctionlistSwitch
FunctionlistDeactivated
enable 0unsignedInt 0…11
EnableunsignedInt 0…11
GO 1listOff
GO 1unsignedInt 0…1000
GO 1unsignedInt 0…2550
GO 1unsignedInt 0…2551
GO 1unsignedInt 1…641
GO 1color#000000
GO 1listAutomatic
GO 2listOff
GO 2unsignedInt 0…1000
GO 2unsignedInt 0…2550
GO 2unsignedInt 0…2551
GO 2unsignedInt 1…641
GO 2color#000000
GO 2listAutomatic
GO 3listOff
GO 3unsignedInt 0…1000
GO 3unsignedInt 0…2550
GO 3unsignedInt 0…2551
GO 3unsignedInt 1…641
GO 3color#000000
GO 3listAutomatic
GO 4listOff
GO 4unsignedInt 0…1000
GO 4unsignedInt 0…2550
GO 4unsignedInt 0…2551
GO 4unsignedInt 1…641
GO 4color#000000
GO 4listAutomatic
GO 5listOff
GO 5unsignedInt 0…1000
GO 5unsignedInt 0…2550
GO 5unsignedInt 0…2551
GO 5unsignedInt 1…641
GO 5color#000000
GO 5listAutomatic
EnableunsignedInt 0…10
Reaction on long operationlistCorresponds to a short operation
Reaction after last steplistStep 1
Behavior after last steplistNo reaction
Reaction on short operationlistNext step
Reaction on short operationlistPrevious step
Send values after evaluation periodunsignedInt 0…10
Evaluation periodtime2000
Evaluation periodunsignedInt 0…655352000
Enable Group Object "Reset switching sequence"unsignedInt 0…10
App_2ButtonunsignedInt 0…11
ApplicationlistPulse counter template
Parameter SizeunsignedInt 0…6553565
Counter typelist4 bytes unsigned [DPT 12.001]
Generate input pulselistOn closing
Enable Counter 1unsignedInt 0…11
Enable pulse counter 2unsignedInt 0…10
FunctionCodelist
Minimum signal durationunsignedInt 20…10030
Signal typelistDC
Send value of Group Object "Counter value 1"listOn change
Sending cycletime86400
Value is sent from a change ofunsignedInt 1…10000100
Counter-specific settingsunsignedInt 0…10
Start valuesignedInt -128…1270
Initial valuesignedInt -128…1270
Start valueunsignedInt 0…2550
Initial valueunsignedInt 0…2550
Start valuesignedInt -32768…327670
Initial valuesignedInt -32768…327670
Start valueunsignedInt 0…655350
Initial valueunsignedInt 0…655350
Start valuesignedInt -2147483648…21474836470
Initial valuesignedInt -2147483648…21474836470
Start valueunsignedInt 0…42949672950
Initial valueunsignedInt 0…42949672950
Number of input pulses for one counter stepunsignedInt 1…100001
Number of input pulses per counting pulseunsignedInt 1…100001
Change of counter per counter stepsignedInt -10000…100001
Counter reading change per counting pulsesignedInt -10000…100001
Evaluate limit valueunsignedInt 0…10
Limit valuesignedInt -128…127100
Limit valueunsignedInt 0…255100
Limit valuesignedInt -32768…32767100
Limit valueunsignedInt 0…65535100
Limit valuesignedInt -2147483648…2147483647100
Limit valueunsignedInt 0…4294967295100
Reaction on reaching limit valuelistReset to initial value
Send value of Group Object "Counter value 2"listOn change
ApplicationlistSwitch
CHANNEL_MP_CTunsignedInt 0…42949672950
Parameter settingunsignedInt 0…11
BinaryInput_1_TextVirtualtextInput a
BinaryInput_1_StextInput a
BinaryInput_1_DtextInput a+b
ConfigunsignedInt 0…167772150
Input atext
BinaryInput_3_TextVirtualtextInput c
BinaryInput_3_StextInput c
BinaryInput_3_DtextInput c+d
Input ctext
BinaryInput_5_TextVirtualtextInput e
BinaryInput_5_StextInput e
BinaryInput_5_DtextInput e+f
Input etext
BinaryInput_7_TextVirtualtextInput g
BinaryInput_7_StextInput g
BinaryInput_7_DtextInput g+h
Input gtext

Application program: Binary Input 8f 230V/2.0 2.0

Application number$A0EA
Version2.0
Mask versionMV-07B0 (System B)
KNX Data SecureNo
Minimum ETS version5.0
Parameters0
Group objects0
Group objects (0)
NoNameFunctionSizeDPTFlags
Parameters (0)
ParameterTypeDefault

Version history

ApplicationApp noFingerprintFirst seenSizeFile
Binary Input 8f 230V/1.0 1.0 latest$A0EA90D52026-11-251.4 MBDownload

About this file

This is the official ETS product database for the ABB AG - STOTZ-KONTAKT BE/S8.230.3.2 Binary Input, 8-fold, 230V AC/DC, MDRC (2CDG 110 280 R0011), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.

More from ABB AG - STOTZ-KONTAKT

All ABB AG - STOTZ-KONTAKT products