ABB AG - STOTZ-KONTAKT 2CDG 110 219 R0011 HCC/S2.1.2.1 Heating/Cooling Circuit Controller,0-10V,manual operation,2-fold,MDRC

HCC/S2.1.2.1 Heating/Cooling Circuit Controller,0-10V,manual operation,2-fold,MDRC 2CDG 110 219 R0011

ABB AG - STOTZ-KONTAKT · Order number 2CDG 110 219 R0011 · Heating, Ventilation and Air Conditioning › Central HVAC Controllers

Heating/Cooling Circuit Controller, 0-10V, manual operation, 2-f/1.1

Download .knxprod Heating/Cooling Circuit Controller, 0-10V, manual operation, 2-f/1.1 1.1 · 302 KB

Product

ManufacturerABB AG - STOTZ-KONTAKT
Product nameHCC/S2.1.2.1 Heating/Cooling Circuit Controller,0-10V,manual operation,2-fold,MDRC
Order number2CDG 110 219 R0011
HardwareHCC/S2.1.2.1 Heiz-/Kühlkreis Controller,0-10V,manuelle Bedienung,2-fach,REG
MediumTwisted Pair
Bus current (mA)10
Rail mountedYes
Width (mm)70
RegistrationRegistered · 2021-11-18
Languagesen-US, de-DE, es-ES, fr-FR, it-IT, nl-NL, pl-PL, ru-RU
Catalog entryM-0002_H-2CDG.20110.20219.20R0011-2_HP-A0B8-11-058C_CI-2CDG.20110.20219.20R0011-1
Fingerprint058C
SHA-256adeda72c61833be70fd11db1d08e2e014fc86fc3f27236ae60a758f7e0a97639
First seen2026-11-25
Markets59 markets

Application program: Heating/Cooling Circuit Controller, 0-10V, manual operation, 2-f/1.1 1.1

Application number$A0B8
Version1.1
Mask versionMV-07B0 (System B)
KNX Data SecureNo
Minimum ETS version5.0
Parameters456
Group objects118
Group objects (118)
NoNameFunctionSizeDPTFlags
1GeneralIn operation1 Bit1.2 booleanCRT
3GeneralRequest status values1 Bit1.17 triggerCW
4GeneralStatus Manual operation1 Bit1.11 stateCRT
5GeneralEnable/block manual operation1 Bit1.3 enableCW
10Channel A - GeneralForced operation, 2-bit2 Bit2.1 switch controlCW
11Channel A - GeneralForced operation, 1-bit1 Bit1.2 booleanCW
12Channel A - GeneralError "Heating/cooling changeover" receipt1 Bit1.5 alarmCRT
13Channel A - GeneralError "Setpoint temperature" receipt1 Bit1.5 alarmCRT
13Channel A - GeneralError "Control value" receipt1 Bit1.5 alarmCRT
14Channel A - GeneralError "Pump fault" receipt1 Bit1.5 alarmCRT
15Channel A - GeneralError "Pump repair switch" receipt1 Bit1.5 alarmCRT
16Channel A - GeneralStatus byte channel1 ByteCRT
17Channel A - Valve BStatus byte valve B1 ByteCRT
18Channel A - Valve BStatus Control value valve B1 Byte5.1 percentage (0..100%)CRT
19Channel A - Valve BFault Valve output B1 Bit1.5 alarmCRT
20Channel A - Valve BStatus Valve purge B1 Bit1.11 stateCRT
21Channel A - Valve BReset fault Valve output B1 Bit1.15 resetCW
22Channel A - Valve BActivate valve purge B1 Bit1.17 triggerCW
23Channel A - Valve BEnable/block manual valve override B1 Bit1.3 enableCW
24Channel A - Valve BOverride valve control value B1 Byte5.1 percentage (0..100%)CW
26Channel A - PumpOverride pump1 Bit1.1 switchCW
27Channel A - PumpStatus pump relay1 Bit1.9 open/closeCRT
29Channel A - PumpPump fault1 Bit1.5 alarmCWTU
30Channel A - PumpPump repair switch1 Bit1.11 stateCWTU
31Channel A - PumpStatus pump master/slave (1=Master, 0=Slave)1 Bit1.11 stateCRT
32Channel A - PumpEnable/block manual pump override1 Bit1.3 enableCW
33Channel A - PumpStatus pump automatic mode1 Bit1.11 stateCRT
34Channel A - PumpSet time3 Bytes10.1 time of dayCW
35Channel A - PumpMaster/slave changeover1 Bit1.17 triggerCW
37Channel A - Input aSupply flow temperature2 Bytes9.1 temperature (°C)CRT
38Channel A - Input aError Input1 Bit1.5 alarmCRT
39Channel A - Input bReturn flow temperature2 Bytes9.1 temperature (°C)CRT
40Channel A - Input bError Input1 Bit1.5 alarmCRT
41Channel A - Binary input cStatus pump1 Bit1.11 stateCRT
41Channel A - Binary input cContact position binary input1 Bit1.1 switchCRT
42Channel A - Binary input cBlock input1 Bit1.3 enableCW
43Channel A - Binary input dPump fault alarm1 Bit1.5 alarmCRT
43Channel A - Binary input dContact position binary input1 Bit1.1 switchCRT
44Channel A - Binary input dBlock input1 Bit1.3 enableCW
45Channel A - Binary input ePump repair switch 1 Bit1.11 stateCRT
45Channel A - Binary input eContact position binary input1 Bit1.1 switchCRT
46Channel A - Binary input eBlock input1 Bit1.3 enableCW
47Channel A - ControllerStatus Heating/cooling1 Bit1.100 cooling/heatingCRT
48Channel A - ControllerStatus Control value heating1 Byte5.1 percentage (0..100%)CRT
50Channel A - ControllerStatus Control value cooling1 Byte5.1 percentage (0..100%)CRT
54Channel A - ControllerSupply flow temperature receipt2 Bytes9.1 temperature (°C)CWTU
56Channel A - ControllerFault Supply flow temperature1 Bit1.5 alarmCRT
57Channel A - ControllerCurrent setpoint2 Bytes9.1 temperature (°C)CRT
62Channel A - ControllerStatus Heating1 Bit1.1 switchCRT
63Channel A - ControllerStatus Cooling1 Bit1.1 switchCRT
64Channel A - ControllerActivation of minimum control value (basic load)1 Bit1.3 enableCW
65Channel A - ControllerHeating/cooling changeover1 Bit1.100 cooling/heatingCWTU
65Channel A - ActuatorHeating/cooling changeover1 Bit1.100 cooling/heatingCWTU
73Channel A - ControllerActivate/deactivate control1 Bit1.1 switchCW
74Channel A - ControllerStatus Control1 Bit1.1 switchCRT
86Channel A - ControllerHeating setpoint temperature2 Bytes9.1 temperature (°C)CWTU
87Channel A - ControllerCooling setpoint temperature2 Bytes9.1 temperature (°C)CWTU
94Channel A - ActuatorHeating control value1 Byte5.1 percentage (0..100%)CWTU
95Channel A - ActuatorCooling control value1 Byte5.1 percentage (0..100%)CWTU
96Channel A - ControllerTemperature, safety shutdown heating2 Bytes9.1 temperature (°C)CWTU
98Channel A - ControllerTemperature, safety shutdown cooling2 Bytes9.1 temperature (°C)CWTU
100Channel A - ControllerStatus Safety shutdown1 Bit1.5 alarmCRT
101Channel B - GeneralForced operation, 2-bit2 Bit2.1 switch controlCW
102Channel B - GeneralForced operation, 1-bit1 Bit1.2 booleanCW
103Channel B - GeneralError "Heating/cooling changeover" receipt1 Bit1.5 alarmCRT
104Channel B - GeneralError "Setpoint temperature" receipt1 Bit1.5 alarmCRT
104Channel B - GeneralError "Control value" receipt1 Bit1.5 alarmCRT
105Channel B - GeneralError "Pump fault" receipt1 Bit1.5 alarmCRT
106Channel B - GeneralError "Pump repair switch" receipt1 Bit1.5 alarmCRT
107Channel B - GeneralStatus byte channel1 ByteCRT
108Channel B - Valve DStatus byte valve D1 ByteCRT
109Channel B - Valve DStatus Control value valve D1 Byte5.1 percentage (0..100%)CRT
110Channel B - Valve DFault Valve output D1 Bit1.5 alarmCRT
111Channel B - Valve DStatus Valve purge D1 Bit1.11 stateCRT
112Channel B - Valve DReset fault Valve output D1 Bit1.15 resetCW
113Channel B - Valve DActivate valve purge D1 Bit1.17 triggerCW
114Channel B - Valve DEnable/block manual valve override D1 Bit1.3 enableCW
115Channel B - Valve DOverride valve control value D1 Byte5.1 percentage (0..100%)CW
117Channel B - PumpOverride pump1 Bit1.1 switchCW
118Channel B - PumpStatus pump relay1 Bit1.9 open/closeCRT
120Channel B - PumpPump fault1 Bit1.5 alarmCWTU
121Channel B - PumpPump repair switch1 Bit1.11 stateCWTU
122Channel B - PumpStatus pump master/slave (1=Master, 0=Slave)1 Bit1.11 stateCRT
123Channel B - PumpEnable/block manual pump override1 Bit1.3 enableCW
124Channel B - PumpStatus pump automatic mode1 Bit1.11 stateCRT
128Channel B - Input fSupply flow temperature2 Bytes9.1 temperature (°C)CRT
129Channel B - Input fError Input1 Bit1.5 alarmCRT
130Channel B - Input gReturn flow temperature2 Bytes9.1 temperature (°C)CRT
131Channel B - Input gError Input1 Bit1.5 alarmCRT
132Channel B - Binary input hStatus pump1 Bit1.11 stateCRT
132Channel B - Binary input hContact position binary input1 Bit1.1 switchCRT
133Channel B - Binary input hBlock input1 Bit1.3 enableCW
134Channel B - Binary input iPump fault alarm1 Bit1.5 alarmCRT
134Channel B - Binary input iContact position binary input1 Bit1.1 switchCRT
135Channel B - Binary input iBlock input1 Bit1.3 enableCW
136Channel B - Binary input jPump repair switch 1 Bit1.11 stateCRT
136Channel B - Binary input jContact position binary input1 Bit1.1 switchCRT
137Channel B - Binary input jBlock input1 Bit1.3 enableCW
138Channel B - ControllerStatus Heating/cooling1 Bit1.100 cooling/heatingCRT
139Channel B - ControllerStatus Control value heating1 Byte5.1 percentage (0..100%)CRT
141Channel B - ControllerStatus Control value cooling1 Byte5.1 percentage (0..100%)CRT
145Channel B - ControllerSupply flow temperature receipt2 Bytes9.1 temperature (°C)CWTU
147Channel B - ControllerFault Supply flow temperature1 Bit1.5 alarmCRT
148Channel B - ControllerCurrent setpoint2 Bytes9.1 temperature (°C)CRT
153Channel B - ControllerStatus Heating1 Bit1.1 switchCRT
154Channel B - ControllerStatus Cooling1 Bit1.1 switchCRT
155Channel B - ControllerActivation of minimum control value (basic load)1 Bit1.3 enableCW
156Channel B - ControllerHeating/cooling changeover1 Bit1.100 cooling/heatingCWTU
156Channel B - ActuatorHeating/cooling changeover1 Bit1.100 cooling/heatingCWTU
164Channel B - ControllerActivate/deactivate control1 Bit1.1 switchCW
165Channel B - ControllerStatus Control1 Bit1.1 switchCRT
177Channel B - ControllerHeating setpoint temperature2 Bytes9.1 temperature (°C)CWTU
178Channel B - ControllerCooling setpoint temperature2 Bytes9.1 temperature (°C)CWTU
185Channel B - ActuatorHeating control value1 Byte5.1 percentage (0..100%)CWTU
186Channel B - ActuatorCooling control value1 Byte5.1 percentage (0..100%)CWTU
187Channel B - ControllerTemperature, safety shutdown heating2 Bytes9.1 temperature (°C)CWTU
189Channel B - ControllerTemperature, safety shutdown cooling2 Bytes9.1 temperature (°C)CWTU
191Channel B - ControllerStatus Safety shutdown1 Bit1.5 alarmCRT
Parameters (164)
ParameterTypeDefault
Hardware_TypelistHW
Device functionlistStandalone
Sending and switching delay after bus voltage recoveryunsignedInt 2…2552
Value after sending and switching delay has expiredlistLast value received
Limit number of telegramslistNo
Enable group object "In operation"listNo
Send value of group object "In operation"listValue 1
In periodlist1 s
Maximum number of telegramsunsignedInt 1…5020
i-bus Tool accesslistFull access
Sending cycletime60
Channel functionlistController channel
Control value after ETS downloadlistUnchanged
Temperature setpoint after ETS downloadlistUnchanged
Control valueunsignedInt 0…1000
Status after ETS downloadlistUnchanged
Monitor receipt of group object "Setpoint heating/cooling temperature"listDeactivated
Monitor receipt of group objects "Heating/cooling control value"listDeactivated
Cyclical monitoringlistDeactivated
Monitor receipt of group object "Heating/cooling changeover"listDeactivated
Heating temperature setpointunsignedInt 20…10050
Forced operationlistDeactivated
Control value on exceeding the monitoring timeunsignedInt 0…10025
Control value on input faultunsignedInt 0…10025
Monitor supply flow temperaturelistDeactivated
Control value on forced operationunsignedInt 0…1000
Control value during forced operation active "ON"unsignedInt 0…1000
Control value during forced operation active "OFF"unsignedInt 0…1000
Time interval for cyclical monitoringtime300
Operating mode on exceeding the monitoring timelistUnchanged
Valve outputlistActivated
Send status valueslistAfter change or on request
Resistance in ohms at +120°CunsignedInt 650…46003607
Send cyclically everytime300
Temperature offsetfloat -10…100
Cable length, single distancefloat 1…10010
Cross-section of conductor Value* 0.01 mm²unsignedInt 1…150100
Cable resistance (total of fwd and rtn conductor)unsignedInt 0…10000500
Value is sent from a change offloat 0.2…101
Send cyclically everytime30
Temperature inputlistDeactivated
InputlistDeactivated
InputlistPump status input
InputlistPump error input
Minimum control value for basic load > 0listAlways active
I-proportionunsignedInt 5…60060
Type of cooling control valuelistPI continuous (0...100%)
Control value directionlistNormal
Extended settingslistNo
Control value difference for sending control valuelist5 %
Send control value cyclically (0 = deactivated)unsignedInt 0…6015
xP-proportionfloat 1…10060
Maximum control valueunsignedInt 1…100100
Min. control value (basic load)unsignedInt 0…1000
Manual operationlistEnabled
Automatic reset from manual operation to KNX operationlistNo
Object value request on restart and bus voltage recoverylistNo
Valve purgelistAutomatic or via group object
Resistance in ohms at +80°CunsignedInt 650…46002785
Send value of group object "Status Valve purge"listNo, update only
Purge cycle in weeksunsignedInt 1…124
Resistance in ohms at +100°CunsignedInt 650…46003182
Reset purge cycle from control value greater than or equal tounsignedInt 1…9999
Cable error compensationlistNone
Send temperature valuelistAfter change
Temperature sensor typelistPT1000 [-30...+110 °C]
KTY typelistKT 100/110/130
NTC typelistNTC 10-01 [-15...+100 °C]
FilterlistInactive
Resistance in ohms at -20°CunsignedInt 650…46001247
Resistance in ohms at 0°CunsignedInt 650…46001495
Resistance in ohms at +20°CunsignedInt 650…46001772
Resistance in ohms at +40°CunsignedInt 650…46002080
Resistance in ohms at +60°CunsignedInt 650…46002417
Reaction on event 1listOn
GP_CD_A0B8011Ftext
Convertible from version 0.1unsignedInt 0…2551
Switch on pump when control value greater thanunsignedInt 0…995
Switch off pump when control value less than (0% = deactivated)unsignedInt 0…1002
Switch-off delaytime5
Send cyclically everytime60
Enable manual pump overridelistNo
Pump reaction on bus voltage failurelistUnchanged
Pump reaction after bus voltage recoverylistAdopts control value
Use pump channel AlistMain pump
Channel bundling for double pumpslistNo
Changeover point weekdaylistMonday
Changeover point timeunsignedInt 1…241
Changeover timesignedInt -60…600
InputlistPump repair status input
Monitor receipt of pump status group objectlistDeactivated
Monitor receipt of group object "Pump fault"listDeactivated
Monitor receipt of group object "Pump repair switch"listDeactivated
Reaction on exceeding the monitoring timelistCooling control value = 0%
Type of heating control valuelistPI continuous (0...100%)
Supply flow temperature limitationlistNo
Return flow temperature limitationlistNo
Heating/cooling changeoverlistVia group object or via slave
Supply flow temperature limitunsignedInt 10…9040
Return flow temperature limitunsignedInt 10…9040
Control starts again after supply flow temperature change byfloat 0…505
Control starts again after return flow temperature change byfloat 0…505
Operating mode after bus voltage recoverylistAs before bus voltage failure
Control value after bus voltage recoverylistAs before bus voltage failure
Temperature inputlistVia physical device input
I-proportion with safety shutdownlistFreeze
Activate safety shutdownlistNo
Safety shutdown hysteresisfloat 0.5…51
Activate heating vialistValve output
Output for heating stagelistValve output
Time for automatic reset to KNX operationtime300
Activate cooling vialistValve output
Output for cooling stagelistValve output
On group object valuelist0 or 1
Cooling temperature setpointunsignedInt 1…3010
Run-on behavior after pump shutdown via manual operationlistYes
Indicate active forced operation with flashing pump status LEDlistNo
Minimum heating setpoint temperatureunsignedInt 10…10020
Maximum heating setpoint temperatureunsignedInt 10…10080
Minimum cooling setpoint temperatureunsignedInt 1…458
Maximum cooling setpoint temperatureunsignedInt 1…4512
Use pump channel BlistMain pump
Close valve when pump is switched offlistYes
Permit pump changeover via manual operationlistYes
Automatic pump shutdown on valve closure via manual operationlistNo
Pump reaction on forced operationlistOn
Pump reaction during forced operation active "ON"listOn
Pump reaction during forced operation active "OFF"listOff
Controller setting coolinglistDeactivated
Controller setting heatinglistMedium temperature accuracy / medium number of valve movements
Safety shutdown temperatureunsignedInt 25…10080
Input for temperature limit sensorlistVia group object
Safety shutdown temperatureunsignedInt 1…308
When closing the contactfloat 0…1001
When opening the contactfloat 0…1001
Long operation afterfloat 1…101
Monitor pump statuslistDeactivated
Monitor pump errorlistDeactivated
Monitor pump repair switchlistDeactivated
Return from manual pump override to automatic modelistVia group object or automatic
Reset timetime300
Pump reaction after ETS downloadlistAdopts control value
GP_CD_A0B7011Ftext
Operating mode after ETS download/resetlistHeating
Cooling setpoint temperature on exceeding the monitoring timeunsignedInt 1…3010
Basic load active when controller offlistNo
Control value on exceeding the monitoring timeunsignedInt 0…10050
Heating setpoint temperature on exceeding the monitoring timeunsignedInt 20…10050
Scan input after download, ETS reset or bus voltage recoverylistYes
Active detected iflistContact closed
Send status valueslistAfter change
Enable group object "Block input"listNo
Input on operationlistClosed
Activate minimum signal durationlistNo
Distinction between long and short operationlistNo
Reaction on event 0listOff
Valve typelistNormal
Voltage range valve control valuelist0 - 10 V
Valve drive opening/closing timeunsignedInt 10…900180
Send inactive control values cyclicallylistNo
Temperature setpoint after bus voltage recoverylistAs before bus voltage failure
Switch on pump automatically when pump automatic OfflistYes
Fault Reset valve outputlistVia group object
Enable manual valve overridelistNo

Version history

ApplicationApp noFingerprintFirst seenSizeFile
Heating/Cooling Circuit Controller, 0-10V, manual operation, 2-f/1.1 1.1 latest$A0B8058C2026-11-25302 KBDownload

About this file

This is the official ETS product database for the ABB AG - STOTZ-KONTAKT HCC/S2.1.2.1 Heating/Cooling Circuit Controller,0-10V,manual operation,2-fold,MDRC (2CDG 110 219 R0011), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.

More from ABB AG - STOTZ-KONTAKT

All ABB AG - STOTZ-KONTAKT products