LK/S4.2 Line/Area Coupler,MDRC 2CDG 110 171 R0011
ABB AG - STOTZ-KONTAKT · Order number 2CDG 110 171 R0011 · System Infrastructure and Interfacing › Line Couplers
Couple Repeat/2.1b
Download .knxprod Couple Repeat/2.1b 3.1 · 69 KB
Product
| Manufacturer | ABB AG - STOTZ-KONTAKT |
|---|---|
| Product name | LK/S4.2 Line/Area Coupler,MDRC |
| Order number | 2CDG 110 171 R0011 |
| Hardware | Koppler LK/S4.2 |
| Medium | Twisted Pair |
| Bus current (mA) | 12 |
| Rail mounted | Yes |
| Width (mm) | 36 |
| Device kind | Coupler |
| Registration | Registered |
| Languages | en-US, de-DE, es-ES, fr-FR, it-IT, nl-NL, pl-PL, ru-RU |
| Catalog entry | M-0002_H-2CDG.20110.20171.20R0011-1_HP-A014-31-C19F_CI-2CDG.20110.20171.20R0011-1 |
| Fingerprint | C19F |
| SHA-256 | f2aba0355d44dd55e0d97a8e72cb3b25795b9135ae354b3b498266a04af54caf |
| First seen | 2026-11-25 |
| Markets | 59 markets |
Application program: Couple Repeat/2.1b 3.1
| Application number | $A014 |
|---|---|
| Version | 3.1 |
| Mask version | MV-0912 (Coupler 0912) |
| KNX Data Secure | No |
| Minimum ETS version | 4.0 |
| Parameters | 41 |
| Group objects | 0 |
Group objects (0)
| No | Name | Function | Size | DPT | Flags |
|---|
Parameters (24)
| Parameter | Type | Default |
|---|---|---|
| Device function | list | Line/Area Coupler |
| Group telegrams main group 0...13 | list | filter |
| Group telegrams main group 14...31 | list | filter |
| Physically addressed telegrams | list | filter |
| Broadcast telegrams | list | route |
| In case of errors repeat telegrams | list | yes |
| Repeat group addressed telegrams | list | yes |
| Repeat group addressed telegrams | unsignedInt 1…1 | 1 |
| Repeat group addressed telegrams | unsignedInt 0…0 | 0 |
| Repeat physically addressed telegrams | list | yes |
| Physikalisch adressierte Telegramme wiederholen | unsignedInt 1…1 | 1 |
| Physikalisch adressierte Telegramme wiederholen | unsignedInt 0…0 | 0 |
| Repeat broadcast telegrams | list | yes |
| Broadcast Telegramme wiederholen | unsignedInt 1…1 | 1 |
| Broadcast Telegramme wiederholen | unsignedInt 0…0 | 0 |
| Telegram confirmation | list | only if routed |
| In case of errors repeat group addressed telegrams on main line | list | yes |
| In case of errors repeat group addressed telegrams on line | list | yes |
| Dummy_alle GA werden weitergel. | unsignedInt 5…5 | 5 |
| PID_54__NOT_USED_SHALL_BE_0 | unsignedInt 0…0 | 0 |
| PID_55__NOT_USED_SHALL_BE_0 | unsignedInt 0…0 | 0 |
| PID_52__VERSTÄRKER_DUMMY_VALUE | unsignedInt 99…99 | 99 |
| PID_53__VERSTÄRKER_DUMMY_VALUE | unsignedInt 99…99 | 99 |
| If free group address structure is used: Main group 0...13 => 1...28,671 Main group 14...31 => 28,672...65,535 | list | <--- NOTE |
Version history
| Application | App no | Fingerprint | First seen | Size | File |
|---|---|---|---|---|---|
| Couple Repeat/2.1b 3.1 latest | $A014 | C19F | 2026-11-25 | 69 KB | Download |
About this file
This is the official ETS product database for the ABB AG - STOTZ-KONTAKT LK/S4.2 Line/Area Coupler,MDRC (2CDG 110 171 R0011), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.
More from ABB AG - STOTZ-KONTAKT
- EG/A32.2.1 KNX/EnOcean Gateway 2 CDG 120 047 R0011
- IPR/S3.1.1 IP Router,MDRC 2CDG 110 175 R0011
- IPR/S3.5.1 IP Router Secure,MDRC 2CDG 110 176 R0011
- IPS/S3.1.1 IP Interface,MDRC 2CDG 110 177 R0011
- IPS/S3.5.1 IP Interface Secure,MDRC 2CDG 110 204 R0011
- USB/S1.2 USB Interface, MDRC 2CDG 110 243 R0011
- LK/S4.3 Line/Area/Segment Coupler Secure,MDRC 2CDG 110 310 R0011
- MG/S11.100.1.1 Modbus RTU - KNX TP Gateway, 100 Points 2CDG 120 089 R0011
- PS5604-KNX AC500 1SAP 195 800 R0101
- Sidus KNX Tastsensor 1-/2-fach, UP 2CCA 380 319 R0001
- Sidus KNX control element 2/4gang, flush-mounted 2CCA 380 339 R0001
- Sidus KNX Tastsensor 4-/8-fach, UP 2CCA 380 375 R0001