KNX Database
ABB AG - STOTZ-KONTAKT 2CDG 110 109 R0011 MT/S4.12.2M Security Terminal,4-fold,MDRC

MT/S4.12.2M Security Terminal,4-fold,MDRC 2CDG 110 109 R0011

ABB AG - STOTZ-KONTAKT · Order number 2CDG 110 109 R0011 · Security - System KNX › Security Modules and Terminals

Monitor Report Display 4f/1.0d

Download .knxprod Monitor Report Display 4f/1.0d 1.0 · 189 KB

Product

ManufacturerABB AG - STOTZ-KONTAKT
Product nameMT/S4.12.2M Security Terminal,4-fold,MDRC
Order number2CDG 110 109 R0011
HardwareMT/S4.12.2M
MediumTwisted Pair
Bus current (mA)6
Rail mountedYes
Width (mm)70
RegistrationRegistered
Languagesen-US, de-DE, es-ES, fr-FR, it-IT, nl-NL, pl-PL, ru-RU
Catalog entryM-0002_H-2CDG.20110.20109.20R0011-1_HP-A041-10-5B42_CI-2CDG.20110.20109.20R0011-1
Fingerprint5B42
SHA-256042b26ef140707486c3dd9809ef25e6d25160261eca17988653a21c9c7386efa
First seen2026-11-25
Markets59 markets

Application program: Monitor Report Display 4f/1.0d 1.0

Application number$A041
Version1.0
Mask versionMV-0701 (7.1)
KNX Data SecureNo
Minimum ETS version3.0
Parameters281
Group objects51
Group objects (51)
NoNameFunctionSizeDPTFlags
0Device statusIn operation/fault 12 V1 BitCRT
1SettingInternal setting/unsetting1 BitCW
2SettingStatus Internally set1 BitCRT
3SettingExternal setting/unsetting1 BitCW
4SettingStatus Externally set1 BitCRT
5SettingStatus Int. or ext. set1 BitCRT
6GeneralReset1 BitCW
7GeneralStatus Reset1 BitCRT
7GeneralReset key1 BitCT
8Output 1Switch1 BitCW
9Output 2Switch1 BitCW
10Output 3Switch1 BitCW
11Output 1Status1 BitCRT
12Output 2Status1 BitCRT
13Output 3Status1 BitCRT
14Manual operationEnable/block manual operation1 BitCW
15Manual operationStatus Manual operation1 BitCRT
16SettingStatus Ready to set (intern.)1 BitCRT
17SettingStatus Ready to set (extern.)1 BitCRT
18SettingSetting confirmation1 BitCT
19SettingUnsetting confirmation1 BitCT
20SettingError during setting1 BitCT
21SettingDelay time active1 BitCT
22SettingAlarm delay is active1 BitCT
23AlarmingInternal signaling device1 BitCRT
24AlarmingExternal signaling device1 BitCRT
25AlarmingIntrusion alarm1 BitCRT
26AlarmingHold up alarm1 BitCRT
27AlarmingTechnical alarm1 BitCRT
28AlarmingTamper alarm1 BitCRT
30Zone AStatus1 BitCRT
31Zone BStatus1 BitCRT
32Zone CStatus1 BitCRT
33Zone DStatus1 BitCRT
38Zone ASetting tamper1 BitCRT
38Zone AAlarm memory1 BitCRT
39Zone BSetting tamper1 BitCRT
39Zone BAlarm memory1 BitCRT
40Zone CSetting tamper1 BitCRT
40Zone CAlarm memory1 BitCRT
41Zone DSetting tamper1 BitCRT
41Zone DAlarm memory1 BitCRT
46Zone ASet/unset request1 BitCRWT
47Zone BSet/unset request1 BitCRWT
48Zone CSet/unset request1 BitCRWT
49Zone DSet/unset request1 BitCRWT
54Zone ADeactivate alarm logic1 BitCW
55Zone BDeactivate alarm logic1 BitCW
56Zone CDeactivate alarm logic1 BitCW
57Zone DDeactivate alarm logic1 BitCW
62Device statusRequest status values1 BitCW
Parameters (66)
ParameterTypeDefault
GeneralunsignedInt 0…10
Operation modelistStand-alone alarm logic
Sending and switching delay after bus voltage recovery in s [2...255]unsignedInt 2…2552
Enable communication object "In operation/fault 12 V" 1 bitlistNo
Send object valuelistNot cyclical: 0 = OK, 1 = Error
Telegram repeated every in sec [1...65,535]unsignedInt 1…6553560
Reset fault 12 VlistAutomatically, if error has been eliminated
Reset object "In operation/fault 12 V"listAutomatically, if error has been eliminated
Fault of 12 V DC auxiliary voltage triggers tamper alarmlistNo
Send alarm messages cyclicallylistNo
Telegrams repeated every in sec [10...3600]unsignedInt 10…360060
Enable communication object "Request status values" 1 bitlistNo
Request with object valuelist1
Manual operationunsignedInt 0…10
Manual operationlistEnable/disable via push button
Reset from manual operation to KNX operationlistAutomatically and via push button
Time to reset automatic operation in s [10...6,000]unsignedInt 10…600060
Enable communication object "Status Man. operation" 1 bitlistNo
Send object valuelistAfter a change
Key "Reset"listEnabled
Key "Out 1"listEnabled
Key "Out 2"listEnabled
Key "Out 3"listEnabled
SettingunsignedInt 0…10
Type of external settinglistNormal
Setting delay in s [1...3600]unsignedInt 1…360060
Alarm delay in s [1...3600]unsignedInt 1…360060
Reaction, peri. intrusion detector, type "Delayed", when internally setlistTriggers alarm instantly
Reaction of peri. intrusion detector, type "Delayed", during delay timelistNo reaction
Reaction of run-out of delay periodlistRemain unset, send error message
Length of setting confirmationlist3 s
Period of unsetting confirmationlist3 s
Period of message "Error during setting"list3 s
Zone AunsignedInt 0…10
InputlistInternal intrusion detector
InputlistStandard zone
BehaviorlistButton
FunctionlistMonitored N/C contact (2.7 kOhm + 560 Ohm)
Type of monitoringlistEOL resistor (2.7 kOhm)
Deactivate via objectlistNo
Enable communication object "Alarm memory" 1 bitlistNo
Prevent setting if detector triggeredlistNo
Type of settinglistInternally switch to set/unset
Reset technical alarmlistAutomatically, if error has been eliminated
Send status cyclicallylistNo
Telegram repeated every in sec [8...3600]unsignedInt 8…360060
Set minimum signal time manuallylistNo
Time base for minimum signal timelist10 ms
Factor for minimum signal timeunsignedInt 1…25510
Zone BunsignedInt 0…10
Zone CunsignedInt 0…10
Zone DunsignedInt 0…10
Monitoring typelistEOL resistor (2.7 kOhm)
ZonelistNo
Output 1unsignedInt 0…10
Operation mode of outputlistNo function
Selection of status informationlistUnset
Enable function TimelistNo
Time for ON in 0.1 s [4...65,535]unsignedInt 4…655354
Time for OFF in 0.1 s [4...65,535]unsignedInt 4…655354
Number of pulses [1...255]unsignedInt 1…2551
Start function Time if object (switching) islistON (1)
Invert outputlistNo
Output reaction after bus voltage recoverylistContact unchanged
Output 2unsignedInt 0…10
Output 3unsignedInt 0…10

Version history

ApplicationApp noFingerprintFirst seenSizeFile
Monitor Report Display 4f/1.0d 1.0 latest$A0415B422026-11-25189 KBDownload

About this file

This is the official ETS product database for the ABB AG - STOTZ-KONTAKT MT/S4.12.2M Security Terminal,4-fold,MDRC (2CDG 110 109 R0011), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.

More from ABB AG - STOTZ-KONTAKT