MT/S4.12.2M Security Terminal,4-fold,MDRC 2CDG 110 109 R0011
ABB AG - STOTZ-KONTAKT · Order number 2CDG 110 109 R0011 · Security - System KNX › Security Modules and Terminals
Monitor Report Display 4f/1.0d
Download .knxprod Monitor Report Display 4f/1.0d 1.0 · 189 KB
Product
| Manufacturer | ABB AG - STOTZ-KONTAKT |
|---|---|
| Product name | MT/S4.12.2M Security Terminal,4-fold,MDRC |
| Order number | 2CDG 110 109 R0011 |
| Hardware | MT/S4.12.2M |
| Medium | Twisted Pair |
| Bus current (mA) | 6 |
| Rail mounted | Yes |
| Width (mm) | 70 |
| Registration | Registered |
| Languages | en-US, de-DE, es-ES, fr-FR, it-IT, nl-NL, pl-PL, ru-RU |
| Catalog entry | M-0002_H-2CDG.20110.20109.20R0011-1_HP-A041-10-5B42_CI-2CDG.20110.20109.20R0011-1 |
| Fingerprint | 5B42 |
| SHA-256 | 042b26ef140707486c3dd9809ef25e6d25160261eca17988653a21c9c7386efa |
| First seen | 2026-11-25 |
| Markets | 59 markets |
Application program: Monitor Report Display 4f/1.0d 1.0
| Application number | $A041 |
|---|---|
| Version | 1.0 |
| Mask version | MV-0701 (7.1) |
| KNX Data Secure | No |
| Minimum ETS version | 3.0 |
| Parameters | 281 |
| Group objects | 51 |
Group objects (51)
| No | Name | Function | Size | DPT | Flags |
|---|---|---|---|---|---|
| 0 | Device status | In operation/fault 12 V | 1 Bit | CRT | |
| 1 | Setting | Internal setting/unsetting | 1 Bit | CW | |
| 2 | Setting | Status Internally set | 1 Bit | CRT | |
| 3 | Setting | External setting/unsetting | 1 Bit | CW | |
| 4 | Setting | Status Externally set | 1 Bit | CRT | |
| 5 | Setting | Status Int. or ext. set | 1 Bit | CRT | |
| 6 | General | Reset | 1 Bit | CW | |
| 7 | General | Status Reset | 1 Bit | CRT | |
| 7 | General | Reset key | 1 Bit | CT | |
| 8 | Output 1 | Switch | 1 Bit | CW | |
| 9 | Output 2 | Switch | 1 Bit | CW | |
| 10 | Output 3 | Switch | 1 Bit | CW | |
| 11 | Output 1 | Status | 1 Bit | CRT | |
| 12 | Output 2 | Status | 1 Bit | CRT | |
| 13 | Output 3 | Status | 1 Bit | CRT | |
| 14 | Manual operation | Enable/block manual operation | 1 Bit | CW | |
| 15 | Manual operation | Status Manual operation | 1 Bit | CRT | |
| 16 | Setting | Status Ready to set (intern.) | 1 Bit | CRT | |
| 17 | Setting | Status Ready to set (extern.) | 1 Bit | CRT | |
| 18 | Setting | Setting confirmation | 1 Bit | CT | |
| 19 | Setting | Unsetting confirmation | 1 Bit | CT | |
| 20 | Setting | Error during setting | 1 Bit | CT | |
| 21 | Setting | Delay time active | 1 Bit | CT | |
| 22 | Setting | Alarm delay is active | 1 Bit | CT | |
| 23 | Alarming | Internal signaling device | 1 Bit | CRT | |
| 24 | Alarming | External signaling device | 1 Bit | CRT | |
| 25 | Alarming | Intrusion alarm | 1 Bit | CRT | |
| 26 | Alarming | Hold up alarm | 1 Bit | CRT | |
| 27 | Alarming | Technical alarm | 1 Bit | CRT | |
| 28 | Alarming | Tamper alarm | 1 Bit | CRT | |
| 30 | Zone A | Status | 1 Bit | CRT | |
| 31 | Zone B | Status | 1 Bit | CRT | |
| 32 | Zone C | Status | 1 Bit | CRT | |
| 33 | Zone D | Status | 1 Bit | CRT | |
| 38 | Zone A | Setting tamper | 1 Bit | CRT | |
| 38 | Zone A | Alarm memory | 1 Bit | CRT | |
| 39 | Zone B | Setting tamper | 1 Bit | CRT | |
| 39 | Zone B | Alarm memory | 1 Bit | CRT | |
| 40 | Zone C | Setting tamper | 1 Bit | CRT | |
| 40 | Zone C | Alarm memory | 1 Bit | CRT | |
| 41 | Zone D | Setting tamper | 1 Bit | CRT | |
| 41 | Zone D | Alarm memory | 1 Bit | CRT | |
| 46 | Zone A | Set/unset request | 1 Bit | CRWT | |
| 47 | Zone B | Set/unset request | 1 Bit | CRWT | |
| 48 | Zone C | Set/unset request | 1 Bit | CRWT | |
| 49 | Zone D | Set/unset request | 1 Bit | CRWT | |
| 54 | Zone A | Deactivate alarm logic | 1 Bit | CW | |
| 55 | Zone B | Deactivate alarm logic | 1 Bit | CW | |
| 56 | Zone C | Deactivate alarm logic | 1 Bit | CW | |
| 57 | Zone D | Deactivate alarm logic | 1 Bit | CW | |
| 62 | Device status | Request status values | 1 Bit | CW |
Parameters (66)
| Parameter | Type | Default |
|---|---|---|
| General | unsignedInt 0…1 | 0 |
| Operation mode | list | Stand-alone alarm logic |
| Sending and switching delay after bus voltage recovery in s [2...255] | unsignedInt 2…255 | 2 |
| Enable communication object "In operation/fault 12 V" 1 bit | list | No |
| Send object value | list | Not cyclical: 0 = OK, 1 = Error |
| Telegram repeated every in sec [1...65,535] | unsignedInt 1…65535 | 60 |
| Reset fault 12 V | list | Automatically, if error has been eliminated |
| Reset object "In operation/fault 12 V" | list | Automatically, if error has been eliminated |
| Fault of 12 V DC auxiliary voltage triggers tamper alarm | list | No |
| Send alarm messages cyclically | list | No |
| Telegrams repeated every in sec [10...3600] | unsignedInt 10…3600 | 60 |
| Enable communication object "Request status values" 1 bit | list | No |
| Request with object value | list | 1 |
| Manual operation | unsignedInt 0…1 | 0 |
| Manual operation | list | Enable/disable via push button |
| Reset from manual operation to KNX operation | list | Automatically and via push button |
| Time to reset automatic operation in s [10...6,000] | unsignedInt 10…6000 | 60 |
| Enable communication object "Status Man. operation" 1 bit | list | No |
| Send object value | list | After a change |
| Key "Reset" | list | Enabled |
| Key "Out 1" | list | Enabled |
| Key "Out 2" | list | Enabled |
| Key "Out 3" | list | Enabled |
| Setting | unsignedInt 0…1 | 0 |
| Type of external setting | list | Normal |
| Setting delay in s [1...3600] | unsignedInt 1…3600 | 60 |
| Alarm delay in s [1...3600] | unsignedInt 1…3600 | 60 |
| Reaction, peri. intrusion detector, type "Delayed", when internally set | list | Triggers alarm instantly |
| Reaction of peri. intrusion detector, type "Delayed", during delay time | list | No reaction |
| Reaction of run-out of delay period | list | Remain unset, send error message |
| Length of setting confirmation | list | 3 s |
| Period of unsetting confirmation | list | 3 s |
| Period of message "Error during setting" | list | 3 s |
| Zone A | unsignedInt 0…1 | 0 |
| Input | list | Internal intrusion detector |
| Input | list | Standard zone |
| Behavior | list | Button |
| Function | list | Monitored N/C contact (2.7 kOhm + 560 Ohm) |
| Type of monitoring | list | EOL resistor (2.7 kOhm) |
| Deactivate via object | list | No |
| Enable communication object "Alarm memory" 1 bit | list | No |
| Prevent setting if detector triggered | list | No |
| Type of setting | list | Internally switch to set/unset |
| Reset technical alarm | list | Automatically, if error has been eliminated |
| Send status cyclically | list | No |
| Telegram repeated every in sec [8...3600] | unsignedInt 8…3600 | 60 |
| Set minimum signal time manually | list | No |
| Time base for minimum signal time | list | 10 ms |
| Factor for minimum signal time | unsignedInt 1…255 | 10 |
| Zone B | unsignedInt 0…1 | 0 |
| Zone C | unsignedInt 0…1 | 0 |
| Zone D | unsignedInt 0…1 | 0 |
| Monitoring type | list | EOL resistor (2.7 kOhm) |
| Zone | list | No |
| Output 1 | unsignedInt 0…1 | 0 |
| Operation mode of output | list | No function |
| Selection of status information | list | Unset |
| Enable function Time | list | No |
| Time for ON in 0.1 s [4...65,535] | unsignedInt 4…65535 | 4 |
| Time for OFF in 0.1 s [4...65,535] | unsignedInt 4…65535 | 4 |
| Number of pulses [1...255] | unsignedInt 1…255 | 1 |
| Start function Time if object (switching) is | list | ON (1) |
| Invert output | list | No |
| Output reaction after bus voltage recovery | list | Contact unchanged |
| Output 2 | unsignedInt 0…1 | 0 |
| Output 3 | unsignedInt 0…1 | 0 |
Version history
| Application | App no | Fingerprint | First seen | Size | File |
|---|---|---|---|---|---|
| Monitor Report Display 4f/1.0d 1.0 latest | $A041 | 5B42 | 2026-11-25 | 189 KB | Download |
About this file
This is the official ETS product database for the ABB AG - STOTZ-KONTAKT MT/S4.12.2M Security Terminal,4-fold,MDRC (2CDG 110 109 R0011), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.
More from ABB AG - STOTZ-KONTAKT
- SCM/S1.1 Security Module,MDRC 2CDG 110 024 R0011
- MT/S8.12.2M Security Terminal,8-fold,MDRC 2CDG 110 110 R0011
- MT/U2.12.2 Security Terminal,2-fold,FM 2CDG 110 111 R0011
- PS5604-KNX AC500 1SAP 195 800 R0101
- EG/A32.2.1 KNX/EnOcean Gateway 2 CDG 120 047 R0011
- Sidus KNX Tastsensor 1-/2-fach, UP 2CCA 380 319 R0001
- Sidus KNX control element 2/4gang, flush-mounted 2CCA 380 339 R0001
- Sidus KNX Tastsensor 4-/8-fach, UP 2CCA 380 375 R0001
- Sidus KNX Movement detector 180° flat 2CCA 388 975 R0001
- Sidus KNX Room temperature controller, FM 2CCA388429R0001
- PM/A 2.8.x.1 Presence detector premium 2CDG 0006 132 R0348
- SBB/U1.1.1 ctrl. el., solo® stand., 1gang, fl. mtd. 2CDG 006 115 R0183