KNX Database
ABB AG - BUSCH-JAEGER 6198/19 EM/S3.16.1 Energy Module, 3F, 16/20A, MDRC

EM/S3.16.1 Energy Module, 3F, 16/20A, MDRC 6198/19

ABB AG - BUSCH-JAEGER · Order number 6198/19 · Energy Management › Energy Modules and Actuators

Download .knxprod Measure 3f/1.0b 1.0 · 220 KB

Product

ManufacturerABB AG - BUSCH-JAEGER
Product nameEM/S3.16.1 Energy Module, 3F, 16/20A, MDRC
Order number6198/19
Product textE/S3.16.1 Energy Actuator, 3F, 16/20A, MDRC
HardwareEM/S3.16.1
MediumTwisted Pair
Bus current (mA)12
Rail mountedYes
RegistrationRegistered
Languagesde-DE, en-US
Catalog entryM-0007_H-2CDH110148R0011-2-O0002_HP-A07E-10-8594-O0002_CI-6198.2F19-1
Fingerprint8594
SHA-256de9cb1d2599ce5f39737114530991817ea4e4ec9860e2503c19c76e05ab3b359
First seen2026-11-25
MarketsAustria, Belgium, Germany, Netherlands

Application program: Measure 3f/1.0b 1.0

Application number$A07E
Version1.0
Mask versionMV-0701 (7.1)
KNX Data SecureNo
Parameters888
Group objects272
Group objects (272)
NoNameFunctionSizeDPTFlags
0SystemIn operation1 Bit1.2 booleanCT
1GeneralSafety priority 11 BitCWU
2GeneralSafety priority 21 BitCWU
3GeneralSafety priority 31 BitCWU
4GeneralRequest status values1 BitCW
5GeneralRequest meter readings1 BitCW
6GeneralRequest instrument values1 BitCW
7GeneralRequest power values1 BitCW
8GeneralReceive time3 Bytes10.1 time of dayCW
9DiagnosisMicrocontroller active1 BitCRT
10Load controlReceive load shedding stage1 ByteCW
11Meter readingEnable reset meters1 Bit1.3 enableCRW
12Meter readingReset meter readings1 BitCW
13Load control masterDeactivate load control 1 Bit1.3 enableCRW
14GeneralRequest external power values1 BitCWT
15Load control masterStatus load control4 BytesCRT
16Load control masterLoad limit exceeded1 BitCRT
17Load control masterReceive power value 14 Bytes14.56 power (W)CWTU
18Load control masterReceive power value 24 Bytes14.56 power (W)CWTU
19Load control masterReceive power value 34 Bytes14.56 power (W)CWTU
20Load control masterReceive power value 44 Bytes14.56 power (W)CWTU
21Load control masterReceive power value 54 Bytes14.56 power (W)CWTU
21Laod Control MasterReceive power value 54 Bytes14.56 power (W)CWTU
22Load control masterReceive power value 64 Bytes14.56 power (W)CWTU
23Load control masterReceive power value 74 Bytes14.56 power (W)CWTU
24Load control masterReceive power value 84 Bytes14.56 power (W)CWTU
25Load control masterReceive power value 94 Bytes14.56 power (W)CWTU
26Load control masterReceive power value 104 Bytes14.56 power (W)CWTU
27Load control masterSend sum power values4 Bytes14.56 power (W)CRT
28Load control masterSend load shedding stage1 ByteCRT
29Load control masterChoose load limit1 Byte5.10 counter pulses (0..255)CW
30Load control masterReceive/send load limit4 Bytes14.56 power (W)CRWT
30Load control masterSend load limit4 Bytes14.56 power (W)CRT
31Meter totalMeter reading4 BytesCRT
32Intermediate meter totalMeter reading4 BytesCRT
33Intermediate meter totalStatus1 ByteCRT
34Intermediate meter totalReceive trigger 11 BitCW
34Intermediate meter totalTrigger 1 change time3 Bytes10.1 time of dayCRWT
35Intermediate meter totalTrigger 2 change duration2 BytesCRWT
35Intermediate meter totalTrigger 2 change limit4 BytesCRWT
35Intermediate meter totalTrigger 2 change time3 Bytes10.1 time of dayCRWT
35Intermediate meter totalReceive trigger 21 BitCW
36Intermediate meter totalReset1 BitCW
37Active power totalActive power 4 Bytes14.56 power (W)CRT
38Active power totalLower limit threshold 14 Bytes14.56 power (W)CRWT
39Active power totalUpper limit threshold 14 Bytes14.56 power (W)CRWT
40Active power totalWarning threshold 11 BitCRT
41Active power totalLower limit threshold 24 Bytes14.56 power (W)CRWT
42Active power totalUpper limit threshold 24 Bytes14.56 power (W)CRWT
43Active power totalWarning threshold 21 BitCRT
44FrequencyFrequency4 Bytes14.33 frequency (Hz)CRT
45FrequencyLower limit threshold 14 Bytes14.33 frequency (Hz)CRWT
46FrequencyUpper limit threshold 14 Bytes14.33 frequency (Hz)CRWT
47FrequencyWarning threshold 11 BitCRT
48FrequencyLower limit threshold 24 Bytes14.33 frequency (Hz)CRWT
49FrequencyUpper limit threshold 24 Bytes14.33 frequency (Hz)CRWT
50FrequencyWarning threshold 21 BitCRT
51DiagnosisFrequency error1 BitCRT
52DummyDummy1 Bit
53DummyDummy1 Bit
54DummyDummy1 Bit
55DummyDummy1 Bit
56DummyDummy1 Bit
57DummyDummy1 Bit
58DummyDummy1 Bit
59DummyDummy1 Bit
60A: SwitchingSwitch1 BitCW
61A: SwitchingStatus switch1 BitCRT
62A: DiagnosisStatus byte1 BitCRT
63A: TimePermanent ON1 BitCW
64A: TimeDisable function time1 BitCRWT
65A: Staircase lightingDuration of staircase lighting2 BytesCRWT
66A: Staircase lightingWarning staircase lighting1 BitCT
67A: Scene8 bit scene1 ByteCW
68A: LogicLogical connection 11 BitCW
69A: LogicLogical connection 21 BitCW
70A: Forced operationForced operation1 BitCW
71A: ContactContact monitoring1 BitCRT
72DummyDummy1 Bit
73DummyDummy1 Bit
74A: MeterMeter reading4 BytesCRT
75A: Intermediate meterMeter reading4 BytesCRT
76A: Intermediate meterStatus1 ByteCRT
77A: Intermediate meterReceive trigger 11 BitCW
77A: Intermediate meterTrigger 1 change time3 Bytes10.1 time of dayCRWT
78A: Intermediate meterTrigger 2 change duration2 BytesCRWT
78A: Intermediate meterTrigger 2 change limit4 BytesCRWT
78A: Intermediate meterTrigger 2 change time3 Bytes10.1 time of dayCRWT
78A: Intermediate meterReceive trigger 21 BitCW
79A: Intermediate meterReset1 BitCW
80A: Load control slaveDeactivate load control 1 Bit1.3 enableCRW
81A: Load control slaveLoad shedding stage output1 Byte5.10 counter pulses (0..255)CRWT
82A: Active powerActive power4 Bytes14.56 power (W)CRT
83A: Active powerLower limit threshold 14 Bytes14.56 power (W)CRWT
84A: Active powerUpper limit threshold 14 Bytes14.56 power (W)CRWT
85A: Active powerWarning threshold 11 BitCRT
86A: Active powerLower limit threshold 24 Bytes14.56 power (W)CRWT
87A: Active powerUpper limit threshold 24 Bytes14.56 power (W)CRWT
88A: Active powerWarning threshold 21 BitCRT
89A: CurrentCurrent value4 Bytes14.19 electric current (A)CRT
90A: CurrentLower limit threshold 14 Bytes14.19 electric current (A)CRWT
91A: CurrentUpper limit threshold 14 Bytes14.19 electric current (A)CRWT
92A: CurrentWarning threshold 11 BitCRT
93A: CurrentLower limit threshold 24 Bytes14.19 electric current (A)CRWT
94A: CurrentUpper limit threshold 24 Bytes14.19 electric current (A)CRWT
95A: CurrentWarning threshold 21 BitCRT
96A: VoltageVoltage4 Bytes14.27 electric potential (V)CRT
97A: VoltageLower limit threshold 14 Bytes14.27 electric potential (V)CRWT
98A: VoltageUpper limit threshold 14 Bytes14.27 electric potential (V)CRWT
99A: VoltageWarning threshold 11 BitCRT
100A: VoltageLower limit threshold 24 Bytes14.27 electric potential (V)CRWT
101A: VoltageUpper limit threshold 24 Bytes14.27 electric potential (V)CRWT
102A: VoltageWarning threshold 21 BitCRT
103A: Apparent powerApparent power4 Bytes14.56 power (W)CRT
104A: ReActive powerReactive power total4 Bytes14.56 power (W)CRT
105A: Power factorPower factor4 Bytes14.57 power factor (cos Φ)CRT
106A: Crest factor currentCrest factor4 Bytes14.57 power factor (cos Φ)CRT
107DummyDummy1 Bit
108DummyDummy1 Bit
109DummyDummy1 Bit
110DummyDummy1 Bit
111DummyDummy1 Bit
112DummyDummy1 Bit
113DummyDummy1 Bit
114DummyDummy1 Bit
115DummyDummy1 Bit
116DummyDummy1 Bit
117DummyDummy1 Bit
118DummyDummy1 Bit
119DummyDummy1 Bit
120B: SwitchingSwitch1 BitCW
121B: SwitchingStatus switch1 BitCRT
122B: DiagnosisStatus byte1 BitCRT
123B: TimePermanent ON1 BitCW
124B: TimeDisable function time1 BitCRWT
125B: Staircase lightingDuration of staircase lighting2 BytesCRWT
126B: Staircase lightingWarning staircase lighting1 BitCT
127B: Scene8 bit scene1 ByteCW
128B: LogicLogical connection 11 BitCW
129B: LogicLogical connection 21 BitCW
130B: Forced operationForced operation1 BitCW
131B: ContactContact monitoring1 BitCRT
132DummyDummy1 Bit
133DummyDummy1 Bit
134B: MeterMeter reading4 BytesCRT
135B: Intermediate meterMeter reading4 BytesCRT
136B: Intermediate meterStatus1 ByteCRT
137B: Intermediate meterReceive trigger 11 BitCW
137B: Intermediate meterTrigger 1 change time3 Bytes10.1 time of dayCRWT
138B: Intermediate meterTrigger 2 change duration2 BytesCRWT
138B: Intermediate meterTrigger 2 change limit4 BytesCRWT
138B: Intermediate meterTrigger 2 change time3 Bytes10.1 time of dayCRWT
138B: Intermediate meterReceive trigger 21 BitCW
139B: Intermediate meterReset1 BitCW
140B: Load control slaveDeactivate load control 1 Bit1.3 enableCRW
141B: Load control slaveLoad shedding stage output1 Byte5.10 counter pulses (0..255)CRWT
142B: Active powerActive power4 Bytes14.56 power (W)CRT
143B: Active powerLower limit threshold 14 Bytes14.56 power (W)CRWT
144B: Active powerUpper limit threshold 14 Bytes14.56 power (W)CRWT
145B: Active powerWarning threshold 11 BitCRT
146B: Active powerLower limit threshold 24 Bytes14.56 power (W)CRWT
147B: Active powerUpper limit threshold 24 Bytes14.56 power (W)CRWT
148B: Active powerWarning threshold 21 BitCRT
149B: CurrentCurrent value4 Bytes14.19 electric current (A)CRT
150B: CurrentLower limit threshold 14 Bytes14.19 electric current (A)CRWT
151B: CurrentUpper limit threshold 14 Bytes14.19 electric current (A)CRWT
152B: CurrentWarning threshold 11 BitCRT
153B: CurrentLower limit threshold 24 Bytes14.19 electric current (A)CRWT
154B: CurrentUpper limit threshold 24 Bytes14.19 electric current (A)CRWT
155B: CurrentWarning threshold 21 BitCRT
156B: VoltageVoltage4 Bytes14.27 electric potential (V)CRT
157B: VoltageLower limit threshold 14 Bytes14.27 electric potential (V)CRWT
158B: VoltageUpper limit threshold 14 Bytes14.27 electric potential (V)CRWT
159B: VoltageWarning threshold 11 BitCRT
160B: VoltageLower limit threshold 24 Bytes14.27 electric potential (V)CRWT
161B: VoltageUpper limit threshold 24 Bytes14.27 electric potential (V)CRWT
162B: VoltageWarning threshold 21 BitCRT
163B: Apparent powerApparent power4 Bytes14.56 power (W)CRT
164B: Reactive power Reactive power total4 Bytes14.56 power (W)CRT
165B: Power factorPower factor4 Bytes14.57 power factor (cos Φ)CRT
166B: Crest factor currentCrest factor4 Bytes14.57 power factor (cos Φ)CRT
167DummyDummy1 Bit
168DummyDummy1 Bit
169DummyDummy1 Bit
170DummyDummy1 Bit
171DummyDummy1 Bit
172DummyDummy1 Bit
173DummyDummy1 Bit
174DummyDummy1 Bit
175DummyDummy1 Bit
176DummyDummy1 Bit
177DummyDummy1 Bit
178DummyDummy1 Bit
179DummyDummy1 Bit
180C: SwitchingSwitch1 BitCW
181C: SwitchingStatus switch1 BitCRT
182C: DiagnosisStatus byte1 BitCRT
183C: TimePermanent ON1 BitCW
184C: TimeDisable function time1 BitCRWT
185C: Staircase lightingDuration of staircase lighting2 BytesCRWT
186C: Staircase lightingWarning staircase lighting1 BitCT
187C: Scene8 bit scene1 ByteCW
188C: LogicLogical connection 11 BitCW
189C: LogicLogical connection 21 BitCW
190C: Forced operationForced operation1 BitCW
191C: ContactContact monitoring1 BitCRT
192DummyDummy1 Bit
193DummyDummy1 Bit
194C: MeterMeter reading4 BytesCRT
195C: Intermediate meterMeter reading4 BytesCRT
196C: Intermediate meterStatus1 ByteCRT
197C: Intermediate meterReceive trigger 11 BitCW
197C: Intermediate meterTrigger 1 change time3 Bytes10.1 time of dayCRWT
198C: Intermediate meterTrigger 2 change duration2 BytesCRWT
198C: Intermediate meterTrigger 2 change limit4 BytesCRWT
198C: Intermediate meterTrigger 2 change time3 Bytes10.1 time of dayCRWT
198C: Intermediate meterReceive trigger 21 BitCW
199C: Intermediate meterReset1 BitCW
200C: Load control slaveDeactivate load control 1 Bit1.3 enableCRW
201C: Load control slaveLoad shedding stage output1 Byte5.10 counter pulses (0..255)CRWT
202C: Active powerActive power4 Bytes14.56 power (W)CRT
203C: Active powerLower limit threshold 14 Bytes14.56 power (W)CRWT
204C: Active powerUpper limit threshold 14 Bytes14.56 power (W)CRWT
205C: Active powerWarning threshold 11 BitCRT
206C: Active powerLower limit threshold 24 Bytes14.56 power (W)CRWT
207C: Active powerUpper limit threshold 24 Bytes14.56 power (W)CRWT
208C: Active powerWarning threshold 21 BitCRT
209C: CurrentCurrent value4 Bytes14.19 electric current (A)CRT
210C: CurrentLower limit threshold 14 Bytes14.19 electric current (A)CRWT
211C: CurrentUpper limit threshold 14 Bytes14.19 electric current (A)CRWT
212C: CurrentWarning threshold 11 BitCRT
213C: CurrentLower limit threshold 24 Bytes14.19 electric current (A)CRWT
214C: CurrentUpper limit threshold 24 Bytes14.19 electric current (A)CRWT
215C: CurrentWarning threshold 21 BitCRT
216C: VoltageVoltage4 Bytes14.27 electric potential (V)CRT
217C: VoltageLower limit threshold 14 Bytes14.27 electric potential (V)CRWT
218C: VoltageUpper limit threshold 14 Bytes14.27 electric potential (V)CRWT
219C: VoltageWarning threshold 11 BitCRT
220C: VoltageLower limit threshold 24 Bytes14.27 electric potential (V)CRWT
221C: VoltageUpper limit threshold 24 Bytes14.27 electric potential (V)CRWT
222C: VoltageWarning threshold 21 BitCRT
223C: Apparent powerApparent power4 Bytes14.56 power (W)CRT
224C: Reactive power totalReactive power total4 Bytes14.56 power (W)CRT
225C: Power factorPower factor4 Bytes14.57 power factor (cos Φ)CRT
226C: Crest factor currentCrest factor4 Bytes14.57 power factor (cos Φ)CRT
227DummyDummy1 Bit
228DummyDummy1 Bit
229DummyDummy1 Bit
230DummyDummy1 Bit
231DummyDummy1 Bit
232DummyDummy1 Bit
233DummyDummy1 Bit
234DummyDummy1 Bit
235DummyDummy1 Bit
236DummyDummy1 Bit
237DummyDummy1 Bit
238DummyDummy1 Bit
239DummyDummy1 Bit
240General1 BitCWT
241General4 Bytes
242General4 BytesCWT
243General4 Bytes
244General4 BytesCWT
245General4 Bytes
246General4 Bytes
247General4 BytesCWT
248General4 Bytes
249General4 Bytes
250General4 BytesCWT
251General4 Bytes
252General4 Bytes
253General4 Bytes
Parameters (278)
ParameterTypeDefault
GeneralunsignedInt 0…10
Sending delay after bus voltage recovery in s [2...255]unsignedInt 2…2552
Send communication object "In operation"listno
Telegram is repeated every in s [1...65,535]unsignedInt 0…655350
Telegram is repeated every in s [1...65,535]unsignedInt 1…6553560
Limit number of telegramslistno
Max. number of sent telegramsunsignedInt 1…25520
Max. number of sent telegrams [1...255]unsignedInt 1…25520
in periodlist100 ms
Enable communication object "Request status values" 1 bitlistno
Request with object valuelist1
Enable communication object "Request instrument values" 1 bitlistno
Enable communication object "Request power values" 1 bitlistno
Cycle time for instrument values in s [0...65,535, 0 = do not send cycl.]unsignedInt 0…65535900
Cycle time for power values in s [0...65,535, 0 = do not send cycl.]unsignedInt 0…65535900
Metering (Wh)unsignedInt 0…10
Enable communication object "Request meter readings" 1 bitlistno
Transmission delay meter readings in s [0...65,535]unsignedInt 0…655350
Cycle time for meter readings in s [0...172,800, 0 = do not send cycl.]unsignedInt 0…172800900
All meters resettable per objectlistno
All meters are reset and stoppedlist<--- NOTE
Enable "Meter reading total"listno
FunctionunsignedInt 0…10
Monitor "Active power total"listno
Monitor "Frequency"listno
Device is load control masterlistno
Enable communication object "Receive load shedding stage"listno
Necessary if at least 1 output is load control slavelist<--- NOTE
Enable safety objectslistno
Function safety priority 1listinactive
Control period in seconds [0...65,535, 0 = inactive]unsignedInt 0…655350
Control period in seconds [0...65,535, 0 = inactive]unsignedInt 0…655350
Function safety priority 2listinactive
Function safety priority 3listinactive
Meter reading total (Wh)unsignedInt 0…10
Send "Meter reading total"listno, update only
Send "Intermediate meter reading total"listyes
Cycle time and request objects are set on "Metering (Wh)"list<--- NOTE
Send "Intermediate meter reading total"listno, update only
Trigger 1 (Start) is activated bylist1 bit object
Hour [0...23]unsignedInt 0…230
Minute [0...59]unsignedInt 0…590
Weekdaylistevery day
Reset "Intermediate meter reading total" on trigger 1 (Start)listyes
Send "Intermediate meter reading total" on trigger 1 (Start)listyes
Trigger 2 is activated bylist1 bit object
Duration in min [1...65,535]unsignedInt 0…655355
Limit in Wh [1...120,888,000]unsignedInt 1…1208880005000
"Intermediate meter reading total" is sent on trigger 2list<--- NOTE
Stop "Intermediate meter reading total" on trigger 2listyes
"Intermediate meter reading total" additionally resettable per objectlistno
Value is sent after resetlist<--- NOTE
Overwrite start-, stop time, duration and limit with download or ETS resetlistyes
Active power totalunsignedInt 0…10
Send "Active power" after a changelistno
Send "Active power" when +/- W [1 ... 13,800]unsignedInt 1…1380020
Send "Active power" on requestlistno
Send "Active power" cyclicallylistno
Cycle time and request objects are set on "General"list<--- NOTE
Enable thresholdslistno
Delay for switching in s [0...65.535]unsignedInt 0…655350
Overwrite thresholds with download or ETS resetlistno
Lower limit threshold 1 in W [0...13,800]unsignedInt 0…1380090
Upper limit threshold 1 in W [0...13,800]unsignedInt 0…13800100
Warning threshold 1listdo not send
Enable threshold 2listno
Lower limit threshold 2 in W [0...13,800]unsignedInt 0…13800800
Upper limit threshold 2 in W [0...13,800]unsignedInt 0…138001000
Warning threshold 2listdo not send
FrequencyunsignedInt 0…10
Send "Frequency" after a changelistno
Send "Frequency" when +/- 0.1 Hz x value [1 ... 650]unsignedInt 1…6505
Send "Frequency" on requestlistno
Send "Frequency" cyclicallylistno
Delay for switching in s [0...65,535]unsignedInt 0…655350
Lower limit threshold 1 in 0.1 Hz x value [1...650]unsignedInt 1…650450
Upper limit threshold 1 in 0.1 Hz x value [1...650]unsignedInt 1…650500
Lower limit threshold 2 in 0.1 Hz x value [1...650]unsignedInt 1…650450
Upper limit threshold 2 in 0.1 Hz x value [1...650]unsignedInt 1…650500
Load control masterunsignedInt 0…10
Number of load shedding stages [1...8]unsignedInt 1…82
Load limit can be changedlistyes, object writable
Load limit in W [0...200,000]unsignedInt 0…2000005000
Overwrite load limit with download or ETS resetlistyes
Load limit 1 in W [0...200,000]unsignedInt 0…2000005000
Load limit 2 in W [0...200,000]unsignedInt 0…2000005000
Load limit 3 in W [0...200,000]unsignedInt 0…2000005000
Load limit 4 in W [0...200,000]unsignedInt 0…2000005000
Active load limit after download or ETS resetlistLoad limit 1
Source for power value 1listnone
Source for power value 2listnone
Source for power value 3listnone
Source for power value 4listnone
Number of additional power values [0...6]unsignedInt 0…60
Monitor power values cyclicallylistno
Control period in s [20...65,535]unsignedInt 20…6553520
Reaction time when exceeding load limit in s [2...60]unsignedInt 2…602
Reaction time when falling below load limit in s [2...60]unsignedInt 30…65535300
Hysteresis for increasing load shedding stage in % of load limit [0...100]unsignedInt 0…1000
Object "Deactivate load control" (master) at recovery of bus voltagelistunchanged
Output AunsignedInt 0…10
A: GeneralunsignedInt 0…10
Status response of contact positionlistno
sendlistno, update only
invertedlistno: 1 = closed, 0 = open
Triggering of relaylistonly if calculated change
Manual switching is considered.list<--- NOTE
Delay for interpretationlist300 ms
For contact monitoring and instrument and power valueslist<--- NOTE
Send status "Contact monitoring"listno, update only
Reaction on bus voltage failurelistcontact unchanged
Value object "Switch" on bus voltage recovery and ETS resetlistnot write
Enable objects "Request status values" on "General"list<--- NOTE
A: FunctionunsignedInt 0…10
Enable function time: Delay, staircase lighting, flashinglistno
Value "Disable function time" after bus voltage recovery and ETS resetlist0 = enable function time
Enable function scene (8 bit)listno
Overwrite scene assignment with download or ETS resetlistyes
Enable function logiclistno
Enable functions priority and safety operationlistno
Enable function meteringlistno
Enable function instrument and power valueslistno
Enable function load control slavelistno
A: TimeunsignedInt 0…10
Function timelistStaircase lighting
Flashing if object "Switch" islistON [1] or OFF [0]
Restart of staircase time after end of permanent ONlistno
Time for ON in s [0...65,535]unsignedInt 1…655355
Delay for switching ON in s [0...65,535]unsignedInt 0…655350
Duration of staircase lighting in s [0...65,535]unsignedInt 0…65535300
Time for OFF in s [0...65,535]unsignedInt 1…655355
Delay for switching OFF in s [0...65,535]unsignedInt 0…655350
Number of ON-impulses: [1...100]unsignedInt 1…1005
Extending staircase lighting by multiple operation ["pumping up"]listyes (retriggerable)
Contact position after flashinglistcalculate present contact position
Staircase lighting can be switchedlistON with "1" and OFF with "0"
Warning before end of staircase lightinglistno
Warning time in sec. [0...65,535] add to duration of staircase lightingunsignedInt 0…655350
Duration of staircase lighting can be changed by objectlistno
Note: Consider contact life span and switching cycles per minutelistsee technical data
A: Scenes 1...6unsignedInt 0…10
Assignment to scene number 1...64listno assignment
Standard valuelistON
Enable further sceneslistno
A: Scenes 7...12unsignedInt 0…10
A: Scenes 13...18unsignedInt 0…10
A: LogicunsignedInt 0…10
Logical connection 1listinactive
Function of object "Logical connection 1"listAND
Gate disabled, if object value "Logical connection 1" islist0
Result is invertedlistno
Object "Logical connection 1" after bus voltage recovery or ETS resetlist0
Object "Logical connection 1" after bus voltage recovery or ETS resetlist0
Logical connection 2listinactive
Function of object "Logical connection 2"listAND
Gate disabled, if object value "Logical connection 2" islist0
Object "Logical connection 2" after bus voltage recovery or ETS resetlist0
A: SafetyunsignedInt 0…10
The line position gives the order of priority for safetylist<--- NOTE
Enable "Safety priority x" on "Function"list<--- NOTE
Contact position if safety priority 1listinactive
Contact position if forced operationlistinactive
Object "Forced operation" on bus voltage recovery and ETS resetlistinactive
Object "Forced operation" on bus voltage recovery and ETS resetlist"0" inactive
Contact position if safety priority 2listinactive
Contact position if safety priority 3listinactive
Contact position when forced operation and all safety priority x endlistcalculate present contact position
A: Metering (Wh)unsignedInt 0…10
Send "Meter reading"listno, update only
Enable "Intermediate meter reading"listyes
Send "Intermediate meter reading"listno, update only
Reset "Intermediate meter reading" on trigger 1 (Start)listyes
Send "Intermediate meter reading" on trigger 1 (Start)listyes
Duration in min [1...65,535]unsignedInt 1…655355
Limit in Wh [1...40,296,000]unsignedInt 1…402960005000
"Intermediate meter reading" is sent on trigger 2list<--- NOTE
Stop "Intermediate meter reading" on trigger 2listyes
Reaction to stoplistno reaction
Contact position when limit is reachedlistno reaction
"Intermediate meter reading" additionally resettable per objectlistno
A: Instrument and power valueslistno
Monitor active powerlistno
Monitor currentlistno
Monitor voltagelistno
Enable object "Apparent power"listno
Send "Apparent power" after a changelistno
Send "Apparent power" when +/- VA [1...4,600]unsignedInt 0…46005
Send "Apparent power" on requestlistno
Send "Apparent power" cyclicallylistno
Enable object "Power factor"listno
Send "Power factor" after a changelistno
Send "Power factor" when +/- 0.01 x value [1...100]unsignedInt 1…1005
Send "Power factor" on requestlistno
Send "Power factor" cyclicallylistno
Enable object "Crest factor"listno
Send "Crest factor" after a changelistno
Send "Crest factor" when +/- 0.1 x value [1...100]unsignedInt 1…1005
Send "Crest factor" on requestlistno
Send "Crest factor" cyclicallylistno
A: Monitor active powerunsignedInt 0…10
Send "Active power" when +/- W [1...4,600]unsignedInt 1…46005
Overwrite thresholds with download or ETS resetlistno
Delay for switching in s [0...65,535]unsignedInt 0…655351
Evaluation of threshold 1listalways
Lower limit threshold 1 in W [0...4,600]unsignedInt 0…46005
Upper limit threshold 1 in W [0...4,600]unsignedInt 0…4600100
Contact position when falling below lower limitlistno reaction
Contact position when exceeding upper limitlistno reaction
Evaluation of threshold 2listalways
Lower limit threshold 2 in W [0...4,600]unsignedInt 0…46005
Upper limit threshold 2 in W [0...4,600]unsignedInt 0…4600100
Contact position when falling below lower limitlistno reaction
Contact position when exceeding upper limitlistno reaction
A: Monitor currentunsignedInt 0…10
Send "Current" after a changelistno
Send "Current" when +/- mA [1...20,000]unsignedInt 1…2000050
Send "Current" on requestlistno
Send "Current" cyclicallylistno
Lower limit threshold 1 in 100 mA x value [0...200]unsignedInt 0…2001
Upper limit threshold 1 in 100 mA x value [0...200]unsignedInt 0…2003
Lower limit threshold 2 in 100 mA x value [0...200]unsignedInt 0…200180
Upper limit threshold 2 in 100 mA x value [0...200]unsignedInt 0…200200
A: Monitor voltageunsignedInt 0…10
Send "Voltage" after a changelistno
Send "Voltage" when +/- V [1...265]unsignedInt 1…2655
Send "Voltage" on requestlistno
Send "Voltage" cyclicallylistno
Lower limit threshold 1 in V [95...265]unsignedInt 95…26595
Upper limit threshold 1 in V [95...265]unsignedInt 95…265100
Lower limit threshold 2 in V [95...265]unsignedInt 95…265260
Upper limit threshold 2 in V [95...265]unsignedInt 95…265265
A: Load control slaveunsignedInt 0…10
Load shedding stage output [1...8]unsignedInt 1…81
Load shedding stage can be changed via objectlistno
Overwrite load shedding stage with download or ETS resetlistyes
Slave is controlled vialistexternal object
Enable object "Receive load shedding stage" on "Function"list<--- NOTE
If device is load control masterlist<--- NOTE
Object "Deactivate load control" (slave) at recovery of bus voltagelistunchanged
Output BunsignedInt 0…10
B: GeneralunsignedInt 0…10
Enable objects "Request Status values" on "General"list<--- NOTE
B: FunctionunsignedInt 0…10
Overwrite scene assignment with download or ETS resetlistyes
B: TimeunsignedInt 0…10
Delay for switching OFF in s [0...65,535]unsignedInt 0…6553545
Warning time in sec. [0...65,535] add to duration of staircase lightingunsignedInt 0…6553545
B: Scenes 1...6unsignedInt 0…10
B: Scenes 7...12unsignedInt 0…10
B: Scenes 13...18unsignedInt 0…10
B: LogicunsignedInt 0…10
B: SafetyunsignedInt 0…10
B: Metering (Wh)unsignedInt 0…10
B: Instrument and power valueslistno
B: Monitor active powerunsignedInt 0…10
Upper limit threshold 1 in W [0...4,600]unsignedInt 0…4600100
B: Monitor currentunsignedInt 0…10
B: Monitor voltageunsignedInt 0…10
B: Load control slaveunsignedInt 0…10
Output CunsignedInt 0…10
C: GeneralunsignedInt 0…10
Enable objects "Request status values" on "General"list<--- NOTE
C: FunctionunsignedInt 0…10
C: TimeunsignedInt 0…10
C: Scenes 1...6unsignedInt 0…10
C: Scenes 7...12unsignedInt 0…10
C: Scenes 13...18unsignedInt 0…10
C: LogicunsignedInt 0…10
C: SafetyunsignedInt 0…10
C: Metering (Wh)unsignedInt 0…10
C: Instrument and power valueslistno
C: Monitor active powerunsignedInt 0…10
C: Monitor currentunsignedInt 0…10
C: Monitor voltageunsignedInt 0…10
C: Load control slaveunsignedInt 0…10
Noteslistno
Notes for SE/SunsignedInt 0…10
Mouse on device in ETS topologylist

Version history

ApplicationApp noFingerprintFirst seenSizeFile
Measure 3f/1.0b 1.0 latest$A07E85942026-11-25220 KBDownload

About this file

This is the official ETS product database for the ABB AG - BUSCH-JAEGER EM/S3.16.1 Energy Module, 3F, 16/20A, MDRC (6198/19), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.

More from ABB AG - BUSCH-JAEGER

All ABB AG - BUSCH-JAEGER products