KNX Database
ABB AG - BUSCH-JAEGER 6194/19 SE/S3.16.1 Energy Actuator,3-fold,16/20A,MDRC

SE/S3.16.1 Energy Actuator,3-fold,16/20A,MDRC 6194/19

ABB AG - BUSCH-JAEGER · Order number 6194/19 · Energy Management › Energy Modules and Actuators

Download .knxprod Switch Measure 3f/1.3a 1.3 · 626 KB

Product

ManufacturerABB AG - BUSCH-JAEGER
Product nameSE/S3.16.1 Energy Actuator,3-fold,16/20A,MDRC
Order number6194/19
Product text6194/19 Energy Actuator,3-fold,16/20A,MDRC
HardwareSE/S3.16.1
MediumTwisted Pair
Bus current (mA)12
Rail mountedYes
RegistrationRegistered · 2011-07-15
Languagesde-DE, en-US, fr-FR, es-ES, it-IT, nl-NL, pl-PL, ru-RU
Catalog entryM-0007_H-2CDG.20110.20136.20R0011-1-O0002_HP-A072-13-C45A-O0002_CI-6194.2F19-1
FingerprintC45A
SHA-256ea4acd5d2c23c0591554a9dae2da042f62ab8b9d28b7a8c6e1f8ace9345d7233
First seen2026-11-25
MarketsAustria, Belgium, Germany, Netherlands

Application program: Switch Measure 3f/1.3a 1.3

Application number$A072
Version1.3
Mask versionMV-0701 (7.1)
KNX Data SecureNo
Parameters887
Group objects274
Group objects (274)
NoNameFunctionSizeDPTFlags
0SystemIn operation1 Bit1.2 booleanCT
1GeneralSafety priority 11 BitDPT.1CWU
2GeneralSafety priority 21 BitDPT.1CWU
3GeneralSafety priority 31 BitDPT.1CWU
4GeneralRequest status values1 BitDPT.1CW
5GeneralRequest meter readings1 BitDPT.1CW
6GeneralRequest instrument values1 BitDPT.1CW
7GeneralRequest power values1 BitDPT.1CW
8GeneralReceive time3 Bytes10.1 time of dayCW
9DiagnosticsMeasurement circuit active1 BitDPT.1CRT
10Load controlReceive load shedding stage1 ByteCW
11Meter readingEnable reset meters1 Bit1.3 enableCRW
12Meter readingReset meter readings1 BitDPT.1CW
13Load control masterDeactivate load control 1 Bit1.3 enableCRW
14GeneralRequest external power values1 BitDPT.1CWT
15Load control masterStatus load control4 BytesCRT
16Load control masterLoad limit exceeded1 BitDPT.1CRT
17Load control masterReceive power value 14 Bytes14.56 power (W)CWTU
18Load control masterReceive power value 24 Bytes14.56 power (W)CWTU
19Load control masterReceive power value 34 Bytes14.56 power (W)CWTU
20Load control masterReceive power value 44 Bytes14.56 power (W)CWTU
21Load control masterReceive power value 54 Bytes14.56 power (W)CWTU
22Load control masterReceive power value 64 Bytes14.56 power (W)CWTU
23Load control masterReceive power value 74 Bytes14.56 power (W)CWTU
24Load control masterReceive power value 84 Bytes14.56 power (W)CWTU
25Load control masterReceive power value 94 Bytes14.56 power (W)CWTU
26Load control masterReceive power value 104 Bytes14.56 power (W)CWTU
27Load control masterSend sum power values4 Bytes14.56 power (W)CRT
28Load control masterSend load shedding stage1 ByteCRT
29Load control masterChoose load limit1 Byte5.10 counter pulses (0..255)CW
30Load control masterReceive/send load limit4 Bytes14.56 power (W)CRWT
30Load control masterSend load limit4 Bytes14.56 power (W)CRT
31Meter totalMeter reading4 BytesDPT.13CRT
32Intermediate meter totalMeter reading4 BytesDPT.13CRT
33Intermediate meter totalStatus1 ByteCRT
34Intermediate meter totalReceive trigger 11 BitDPT.1CW
34Intermediate meter totalTrigger 1 change time3 Bytes10.1 time of dayCRWT
35Intermediate meter totalTrigger 2 change duration2 Bytes7.1 pulsesCRWT
35Intermediate meter totalTrigger 2 change limit4 BytesDPT.13CRWT
35Intermediate meter totalTrigger 2 change time3 Bytes10.1 time of dayCRWT
35Intermediate meter totalReceive trigger 21 BitDPT.1CW
36Intermediate meter totalReset1 BitDPT.1CW
37Active power totalActive power 4 Bytes14.56 power (W)CRT
38Active power totalThreshold 1 lower limit4 Bytes14.56 power (W)CRWT
39Active power totalThreshold 1 upper limit4 Bytes14.56 power (W)CRWT
40Active power totalThreshold 1 warning1 BitDPT.1CRT
41Active power totalThreshold 2 lower limit4 Bytes14.56 power (W)CRWT
42Active power totalThreshold 2 upper limit4 Bytes14.56 power (W)CRWT
43Active power totalThreshold 2 warning1 BitDPT.1CRT
44FrequencyFrequency4 Bytes14.33 frequency (Hz)CRT
45FrequencyThreshold 1 lower limit4 Bytes14.33 frequency (Hz)CRWT
46FrequencyThreshold 1 upper limit4 Bytes14.33 frequency (Hz)CRWT
47FrequencyThreshold 1 warning1 BitDPT.1CRT
48FrequencyThreshold 2 lower limit4 Bytes14.33 frequency (Hz)CRWT
49FrequencyThreshold 2 upper limit4 Bytes14.33 frequency (Hz)CRWT
50FrequencyThreshold 2 warning1 BitDPT.1CRT
51DiagnosticsFrequency error1 BitDPT.1CRT
52DummyDummy1 Bit
53DummyDummy1 Bit
54DummyDummy1 Bit
55DummyDummy1 Bit
56DummyDummy1 Bit
57DummyDummy1 Bit
58DummyDummy1 Bit
59DummyDummy1 Bit
60A: SwitchSwitch1 Bit1.1 switchCW
61A: SwitchStatus switch1 Bit1.1 switchCRT
62A: DiagnosticsStatus byte1 ByteCRT
63A: TimePermanent ON1 Bit1.1 switchCW
64A: TimeDisable function time1 Bit1.1 switchCRWT
65A: Staircase lightingStaircase lighting duration2 BytesDPT.7CRWT
66A: Staircase lightingStaircase lighting warning1 BitDPT.1CT
67A: Scene8 bit scene1 ByteCW
68A: LogicLogical connection 11 Bit1.2 booleanCW
69A: LogicLogical connection 21 Bit1.2 booleanCW
70A: Forced operationForced operation1 Bit1.3 enableCW
70A: Forced operationForced operation2 Bit2.1 switch controlCW
71A: ContactContact monitoring1 Bit1.2 booleanCRT
72DummyDummy1 Bit
73DummyDummy1 Bit
74A: MeterMeter reading4 BytesDPT.13CRT
75A: Intermediate meterMeter reading4 BytesDPT.13CRT
76A: Intermediate meterStatus1 ByteCRT
77A: Intermediate meterReceive trigger 11 BitDPT.1CW
77A: Intermediate meterTrigger 1 change time3 Bytes10.1 time of dayCRWT
78A: Intermediate meterTrigger 2 change duration2 BytesDPT.7CRWT
78A: Intermediate meterTrigger 2 change limit4 BytesDPT.13CRWT
78A: Intermediate meterTrigger 2 change time3 Bytes10.1 time of dayCRWT
78A: Intermediate meterReceive trigger 21 BitDPT.1CW
79A: Intermediate meterReset1 BitDPT.1CW
80A: Load control slaveDeactivate load control 1 Bit1.3 enableCRW
81A: Load control slaveLoad shedding stage output1 Byte5.10 counter pulses (0..255)CRWT
82A: Active powerActive power4 Bytes14.56 power (W)CRT
83A: Active powerThreshold 1 lower limit4 Bytes14.56 power (W)CRWT
84A: Active powerThreshold 1 upper limit4 Bytes14.56 power (W)CRWT
85A: Active powerThreshold 1 warning1 BitDPT.1CRT
86A: Active powerThreshold 2 lower limit4 Bytes14.56 power (W)CRWT
87A: Active powerThreshold 2 upper limit4 Bytes14.56 power (W)CRWT
88A: Active powerThreshold 2 warning1 BitDPT.1CRT
89A: CurrentCurrent value4 Bytes14.19 electric current (A)CRT
90A: CurrentThreshold 1 lower limit4 Bytes14.19 electric current (A)CRWT
91A: CurrentThreshold 1 upper limit4 Bytes14.19 electric current (A)CRWT
92A: CurrentThreshold 1 warning1 BitDPT.1CRT
93A: CurrentThreshold 2 lower limit4 Bytes14.19 electric current (A)CRWT
94A: CurrentThreshold 2 upper limit4 Bytes14.19 electric current (A)CRWT
95A: CurrentThreshold 2 warning1 BitDPT.1CRT
96A: VoltageVoltage4 Bytes14.27 electric potential (V)CRT
97A: VoltageThreshold 1 lower limit4 Bytes14.27 electric potential (V)CRWT
98A: VoltageThreshold 1 upper limit4 Bytes14.27 electric potential (V)CRWT
99A: VoltageThreshold 1 warning1 BitDPT.1CRT
100A: VoltageThreshold 2 lower limit4 Bytes14.27 electric potential (V)CRWT
101A: VoltageThreshold 2 upper limit4 Bytes14.27 electric potential (V)CRWT
102A: VoltageThreshold 2 warning1 BitDPT.1CRT
103A: Apparent powerApparent power4 Bytes14.56 power (W)CRT
104A: Reactive powerReactive power total4 Bytes14.56 power (W)CRT
105A: Power factorPower factor4 Bytes14.57 power factor (cos Φ)CRT
106A: Crest factor currentCrest factor current4 Bytes14.57 power factor (cos Φ)CRT
107DummyDummy1 Bit
108DummyDummy1 Bit
109DummyDummy1 Bit
110DummyDummy1 Bit
111DummyDummy1 Bit
112DummyDummy1 Bit
113DummyDummy1 Bit
114DummyDummy1 Bit
115DummyDummy1 Bit
116DummyDummy1 Bit
117DummyDummy1 Bit
118DummyDummy1 Bit
119DummyDummy1 Bit
120B: SwitchSwitch1 Bit1.1 switchCW
121B: SwitchStatus switch1 Bit1.1 switchCRT
122B: DiagnosticsStatus byte1 ByteCRT
123B: TimePermanent ON1 Bit1.1 switchCW
124B: TimeDisable function time1 Bit1.1 switchCRWT
125B: Staircase lightingStaircase lighting duration2 BytesDPT.7CRWT
126B: Staircase lightingStaircase lighting warning1 BitDPT.1CT
127B: Scene8 bit scene1 ByteCW
128B: LogicLogical connection 11 Bit1.2 booleanCW
129B: LogicLogical connection 21 Bit1.2 booleanCW
130B: Forced operationForced operation1 Bit1.3 enableCW
130B: Forced operationForced operation2 Bit2.1 switch controlCW
131B: ContactContact monitoring1 Bit1.2 booleanCRT
132DummyDummy1 Bit
133DummyDummy1 Bit
134B: MeterMeter reading4 BytesDPT.13CRT
135B: Intermediate meterMeter reading4 BytesDPT.13CRT
136B: Intermediate meterStatus1 ByteCRT
137B: Intermediate meterReceive trigger 11 BitDPT.1CW
137B: Intermediate meterTrigger 1 change time3 Bytes10.1 time of dayCRWT
138B: Intermediate meterTrigger 2 change duration2 BytesDPT.7CRWT
138B: Intermediate meterTrigger 2 change limit4 BytesDPT.13CRWT
138B: Intermediate meterTrigger 2 change time3 Bytes10.1 time of dayCRWT
138B: Intermediate meterReceive trigger 21 BitDPT.1CW
139B: Intermediate meterReset1 BitDPT.1CW
140B: Load control slaveDeactivate load control 1 Bit1.3 enableCRW
141B: Load control slaveLoad shedding stage output1 Byte5.10 counter pulses (0..255)CRWT
142B: Active powerActive power4 Bytes14.56 power (W)CRT
143B: Active powerThreshold 1 lower limit4 Bytes14.56 power (W)CRWT
144B: Active powerThreshold 1 upper limit4 Bytes14.56 power (W)CRWT
145B: Active powerThreshold 1 warning1 BitDPT.1CRT
146B: Active powerThreshold 2 lower limit4 Bytes14.56 power (W)CRWT
147B: Active powerThreshold 2 upper limit4 Bytes14.56 power (W)CRWT
148B: Active powerThreshold 2 warning1 BitDPT.1CRT
149B: CurrentCurrent value4 Bytes14.19 electric current (A)CRT
150B: CurrentThreshold 1 lower limit4 Bytes14.19 electric current (A)CRWT
151B: CurrentThreshold 1 upper limit4 Bytes14.19 electric current (A)CRWT
152B: CurrentThreshold 1 warning1 BitDPT.1CRT
153B: CurrentThreshold 2 lower limit4 Bytes14.19 electric current (A)CRWT
154B: CurrentThreshold 2 upper limit4 Bytes14.19 electric current (A)CRWT
155B: CurrentThreshold 2 warning1 BitDPT.1CRT
156B: VoltageVoltage4 Bytes14.27 electric potential (V)CRT
157B: VoltageThreshold 1 lower limit4 Bytes14.27 electric potential (V)CRWT
158B: VoltageThreshold 1 upper limit4 Bytes14.27 electric potential (V)CRWT
159B: VoltageThreshold 1 warning1 BitDPT.1CRT
160B: VoltageThreshold 2 lower limit4 Bytes14.27 electric potential (V)CRWT
161B: VoltageThreshold 2 upper limit4 Bytes14.27 electric potential (V)CRWT
162B: VoltageThreshold 2 warning1 BitDPT.1CRT
163B: Apparent powerApparent power4 Bytes14.56 power (W)CRT
164B: Reactive power Reactive power total4 Bytes14.56 power (W)CRT
165B: Power factorPower factor4 Bytes14.57 power factor (cos Φ)CRT
166B: Crest factor currentCrest factor current4 Bytes14.57 power factor (cos Φ)CRT
167DummyDummy1 Bit
168DummyDummy1 Bit
169DummyDummy1 Bit
170DummyDummy1 Bit
171DummyDummy1 Bit
172DummyDummy1 Bit
173DummyDummy1 Bit
174DummyDummy1 Bit
175DummyDummy1 Bit
176DummyDummy1 Bit
177DummyDummy1 Bit
178DummyDummy1 Bit
179DummyDummy1 Bit
180C: SwitchSwitch1 Bit1.1 switchCW
181C: SwitchStatus switch1 Bit1.1 switchCRT
182C: DiagnosticsStatus byte1 ByteCRT
183C: TimePermanent ON1 Bit1.1 switchCW
184C: TimeDisable function time1 Bit1.1 switchCRWT
185C: Staircase lightingStaircase lighting duration2 BytesDPT.7CRWT
186C: Staircase lightingStaircase lighting warning1 BitDPT.1CT
187C: Scene8 bit scene1 ByteCW
188C: LogicLogical connection 11 Bit1.2 booleanCW
189C: LogicLogical connection 21 Bit1.2 booleanCW
190C: Forced operationForced operation1 Bit1.3 enableCW
190C: Forced operationForced operation2 Bit2.1 switch controlCW
191C: ContactContact monitoring1 Bit1.2 booleanCRT
192DummyDummy1 Bit
193DummyDummy1 Bit
194C: MeterMeter reading4 BytesDPT.13CRT
195C: Intermediate meterMeter reading4 BytesDPT.13CRT
196C: Intermediate meterStatus1 ByteCRT
197C: Intermediate meterReceive trigger 11 BitDPT.1CW
197C: Intermediate meterTrigger 1 change time3 Bytes10.1 time of dayCRWT
198C: Intermediate meterTrigger 2 change duration2 BytesDPT.7CRWT
198C: Intermediate meterTrigger 2 change limit4 BytesDPT.13CRWT
198C: Intermediate meterTrigger 2 change time3 Bytes10.1 time of dayCRWT
198C: Intermediate meterReceive trigger 21 BitDPT.1CW
199C: Intermediate meterReset1 BitDPT.1CW
200C: Load control slaveDeactivate load control 1 Bit1.3 enableCRW
201C: Load control slaveLoad shedding stage output1 Byte5.10 counter pulses (0..255)CRWT
202C: Active powerActive power4 Bytes14.56 power (W)CRT
203C: Active powerThreshold 1 lower limit4 Bytes14.56 power (W)CRWT
204C: Active powerThreshold 1 upper limit4 Bytes14.56 power (W)CRWT
205C: Active powerThreshold 1 warning1 BitDPT.1CRT
206C: Active powerThreshold 2 lower limit4 Bytes14.56 power (W)CRWT
207C: Active powerThreshold 2 upper limit4 Bytes14.56 power (W)CRWT
208C: Active powerThreshold 2 warning1 BitDPT.1CRT
209C: CurrentCurrent value4 Bytes14.19 electric current (A)CRT
210C: CurrentThreshold 1 lower limit4 Bytes14.19 electric current (A)CRWT
211C: CurrentThreshold 1 upper limit4 Bytes14.19 electric current (A)CRWT
212C: CurrentThreshold 1 warning1 BitDPT.1CRT
213C: CurrentThreshold 2 lower limit4 Bytes14.19 electric current (A)CRWT
214C: CurrentThreshold 2 upper limit4 Bytes14.19 electric current (A)CRWT
215C: CurrentThreshold 2 warning1 BitDPT.1CRT
216C: VoltageVoltage4 Bytes14.27 electric potential (V)CRT
217C: VoltageThreshold 1 lower limit4 Bytes14.27 electric potential (V)CRWT
218C: VoltageThreshold 1 upper limit4 Bytes14.27 electric potential (V)CRWT
219C: VoltageThreshold 1 warning1 BitDPT.1CRT
220C: VoltageThreshold 2 lower limit4 Bytes14.27 electric potential (V)CRWT
221C: VoltageThreshold 2 upper limit4 Bytes14.27 electric potential (V)CRWT
222C: VoltageThreshold 2 warning1 BitDPT.1CRT
223C: Apparent powerApparent power4 Bytes14.56 power (W)CRT
224C: Reactive power totalReactive power total4 Bytes14.56 power (W)CRT
225C: Power factorPower factor4 Bytes14.57 power factor (cos Φ)CRT
226C: Crest factor currentCrest factor current4 Bytes14.57 power factor (cos Φ)CRT
227DummyDummy1 Bit
228DummyDummy1 Bit
229DummyDummy1 Bit
230DummyDummy1 Bit
231DummyDummy1 Bit
232DummyDummy1 Bit
233DummyDummy1 Bit
234DummyDummy1 Bit
235DummyDummy1 Bit
236DummyDummy1 Bit
237DummyDummy1 Bit
238DummyDummy1 Bit
239DummyDummy1 Bit
240General Check Inverse CT1 BitCWT
241General Reserved for Properties4 Bytes
242General Reserved for Properties4 BytesCWT
243General Reserved for Properties4 Bytes
244General Reserved for Properties4 BytesCWT
245General Reserved for Properties4 Bytes
246General Reserved for Properties4 Bytes
247General Reserved for Properties4 BytesCWT
248General Reserved for Properties4 Bytes
249General Reserved for Properties4 Bytes
250General Reserved for Properties4 BytesCWT
251General Reserved for Properties4 Bytes
252General Reserved for Properties4 Bytes
253General Reserved for Properties4 Bytes
Parameters (277)
ParameterTypeDefault
GeneralunsignedInt 0…10
Sending delay after bus voltage recovery in s [2...255]unsignedInt 2…2552
Send communication object "In operation"listno
Telegram is repeated every in s [1...65,535]unsignedInt 0…655350
Sending cycle time in s [1...65,535]unsignedInt 1…6553560
Sending cycle time in s [1...65,535]unsignedInt 1…6553560
Limit number of telegramslistno
Max. number of sent telegramsunsignedInt 1…25520
Max. number of sent telegrams [1...255]unsignedInt 1…25520
in periodlist100 ms
Enable communication object "Request status values" 1 bitlistno
Request with object valuelist1
Enable communication object "Request instrument values" 1 bitlistno
Enable communication object "Request power values" 1 bitlistno
Cycle time for instrument values in s [0...65,535, 0 = do not send cycl.]unsignedInt 0…65535900
Cycle time for power values in s [0...65,535, 0 = do not send cycl.]unsignedInt 0…65535900
Metering (Wh)unsignedInt 0…10
Enable communication object "Request meter readings" 1 bitlistno
Transmission delay meter readings in s [0...65,535]unsignedInt 0…655350
Cycle time for meter readings in s [0...172,800, 0 = do not send cycl.]unsignedInt 0…172800900
All meters resettable via objectlistno
All meters are reset and stoppedlist<--- NOTE
Enable "Meter reading total"listno
FunctionunsignedInt 0…10
Monitor "Active power total"listno
Monitor "Frequency"listno
Device is load control masterlistno
Enable communication object "Receive load shedding stage"listno
Necessary if at least 1 output is load control slavelist<--- NOTE
Enable safety objectslistno
Function safety priority 1listinactive
Control period in seconds [0...65,535, 0 = inactive]unsignedInt 0…655350
Control period in seconds [0...65,535, 0 = inactive]unsignedInt 0…655350
Function safety priority 2listinactive
Function safety priority 3listinactive
Meter reading total (Wh)unsignedInt 0…10
Send "Meter reading total"listno, update only
Send "Intermediate meter reading total"listyes
Cycle time and request objects are set on "Metering (Wh)"list<--- NOTE
Send "Intermediate meter reading total"listno, update only
Trigger 1 (Start) is activated bylist1 bit object
Hour [0...23]unsignedInt 0…230
Minute [0...59]unsignedInt 0…590
Weekdaylistevery day
Reset "Intermediate meter reading total" on trigger 1 (Start)listyes
Send "Intermediate meter reading total" on trigger 1 (Start)listyes
Trigger 2 is activated bylist1 bit object
Duration in min [1...65,535]unsignedInt 0…655355
Limit in Wh [1...120,888,000]unsignedInt 1…1208880005000
"Meter reading" is sent on trigger 2list<--- NOTE
Stop "Intermediate meter reading total" on trigger 2listyes
"Intermediate meter reading total" additionally resettable via objectlistno
Value is sent after resetlist<--- NOTE
Overwrite start, stop time, duration and limit with download or ETS resetlistyes
Active power totalunsignedInt 0…10
Send "Active power" after a changelistno
Send "Active power" when +/- W [1 ... 13,800]unsignedInt 1…1380020
Send "Active power" on requestlistno
Send "Active power" cyclicallylistno
Cycle time and request objects are set on "General"list<--- NOTE
Enable thresholdslistno
Delay for switching in s [0...65.535]unsignedInt 0…655350
Overwrite thresholds with download or ETS resetlistno
Threshold 1 lower limit in W [0...13,800]unsignedInt 0…1380090
Threshold 1 upper limit in W [0...13,800]unsignedInt 0…13800100
Threshold 1 warninglistdo not send
Enable threshold 2listno
Threshold 2 lower limit in W [0...13,800]unsignedInt 0…13800800
Threshold 2 upper limit in W [0...13,800]unsignedInt 0…138001000
Threshold 2 warninglistdo not send
FrequencyunsignedInt 0…10
Send "Frequency" after a changelistno
Send "Frequency" when +/- 0.1 Hz x value [1 ... 650]unsignedInt 1…6505
Send "Frequency" on requestlistno
Send "Frequency" cyclicallylistno
Delay for switching in s [0...65,535]unsignedInt 0…655350
Threshold 1 lower limit in 0.1 Hz x value [1...650]unsignedInt 1…650450
Threshold 1 upper limit in 0.1 Hz x value [1...650]unsignedInt 1…650500
Threshold 2 lower limit in 0.1 Hz x value [1...650]unsignedInt 1…650450
Threshold 2 upper limit in 0.1 Hz x value [1...650]unsignedInt 1…650500
Load control masterunsignedInt 0…10
Number of load shedding stages [1...8]unsignedInt 1…82
Load limit can be changedlistyes, object writable
Load limit in W [0...200,000]unsignedInt 0…2000005000
Overwrite load limit with download or ETS resetlistyes
Load limit 1 in W [0...200,000]unsignedInt 0…2000005000
Load limit 2 in W [0...200,000]unsignedInt 0…2000005000
Load limit 3 in W [0...200,000]unsignedInt 0…2000005000
Load limit 4 in W [0...200,000]unsignedInt 0…2000005000
Active load limit after download or ETS resetlistLoad limit 1
Source for power value 1listnone
Source for power value 2listnone
Source for power value 3listnone
Source for power value 4listnone
Number of additional power values [0...6]unsignedInt 0…60
Monitor power values cyclicallylistno
Control period in s [20...65,535]unsignedInt 20…6553520
Reaction time when exceeding load limit in s [2...60]unsignedInt 2…602
Reaction time when falling below load limit in s [30...65535]unsignedInt 30…65535300
Hysteresis for increasing load shedding stage in % of load limit [0...100]unsignedInt 0…1000
Object "Deactivate load control" (master) at recovery of bus voltagelistunchanged
Output AunsignedInt 0…10
A: GeneralunsignedInt 0…10
Status response of contact positionlistno
Sendlistno, update only
Invertedlistno: 1 = closed, 0 = open
Triggering of relaylistonly if calculated change
Manual switching is considered.list<--- NOTE
Delay for interpretationlist300 ms
For contact monitoring and instrument and power valueslist<--- NOTE
Send status "Contact monitoring"listno, update only
Reaction on bus voltage failurelistcontact unchanged
Value object "Switch" on bus voltage recovery and ETS resetlistnot write
Enable objects "Request status values" on "General"list<--- NOTE
A: FunctionunsignedInt 0…10
Enable function time: Delay, staircase lighting, flashinglistno
Value "Disable function time" after bus voltage recovery and ETS resetlist0 = enable function time
Enable function scene (8 bit)listno
Overwrite scene assignment with download or ETS resetlistyes
Enable function logiclistno
Enable functions priority and safety operationlistno
Enable function meteringlistno
Enable function instrument and power valueslistno
Enable function load control slavelistno
A: TimeunsignedInt 0…10
Function timelistStaircase lighting
Flash if object "Switch" islist1 or 0
Restart of staircase time after end of permanent ONlistno
Time for ON in s [0...65,535]unsignedInt 1…655355
Delay for switching ON in s [0...65,535]unsignedInt 0…655350
Staircase lighting duration in s [0...65,535]unsignedInt 0…65535300
Time for OFF in s [0...65,535]unsignedInt 1…655355
Delay for switching OFF in s [0...65,535]unsignedInt 0…655350
Number of flashes: [1...100]unsignedInt 1…1005
Extending staircase lighting by multiple operation ["pumping up"]listyes (retriggerable)
Contact position after flashinglistcalculate present contact position
Staircase lighting can be switchedlistON with 1 and OFF with 0
Warning before end of staircase lightinglistno
Warning time in sec. [0...65,535] add to staircase lighting durationunsignedInt 0…655350
Staircase lighting duration can be changed via objectlistno
Note: Consider contact life span and switching cycles per minutelistsee technical data
A: Scenes 1...6unsignedInt 0…10
Assignment to scene number 1...64listno assignment
Standard valuelistON
Enable further sceneslistno
A: Scenes 7...12unsignedInt 0…10
A: Scenes 13...18unsignedInt 0…10
A: LogicunsignedInt 0…10
Logical connection 1listinactive
Function of object "Logical connection 1"listAND
Gate disabled, if object value "Logical connection 1" islist0
Result is invertedlistno
Object "Logical connection 1" after bus voltage recovery or ETS resetlist0
Logical connection 2listinactive
Function of object "Logical connection 2"listAND
Gate disabled, if object value "Logical connection 2" islist0
Object "Logical connection 2" after bus voltage recovery or ETS resetlist0
A: SafetyunsignedInt 0…10
The line position gives the order of priority for forced operationlist<--- NOTE
Enable "Safety priority x" in parameter window "Function"list<--- NOTE
Contact position if safety priority 1listinactive
Contact position if forced operationlistinactive
Object "Forced operation" on bus voltage recovery and ETS resetlistinactive
Object "Forced operation" on bus voltage recovery and ETS resetlist0 = inactive
Contact position if safety priority 2listinactive
Contact position if safety priority 3listinactive
Contact position when forced operation and all safety priority x endlistcalculate present contact position
A: Metering (Wh)unsignedInt 0…10
Send "Meter reading"listno, update only
Enable "Intermediate meter reading"listyes
Send "Intermediate meter reading"listno, update only
Reset "Intermediate meter reading" on trigger 1 (Start)listyes
Send "Intermediate meter reading" on trigger 1 (Start)listyes
Duration in min [1...65,535]unsignedInt 1…655355
Limit in Wh [1...40,296,000]unsignedInt 1…402960005000
Stop "Intermediate meter reading" on trigger 2listyes
Reaction to stoplistno reaction
Contact position when limit is reachedlistno reaction
"Intermediate meter reading" additionally resettable via objectlistno
A: Instrument and power valueslistno
Monitor active powerlistno
Monitor currentlistno
Monitor voltagelistno
Enable object "Apparent power"listno
Send "Apparent power" after a changelistno
Send "Apparent power" when +/- VA [1...4,600]unsignedInt 0…46005
Send "Apparent power" on requestlistno
Send "Apparent power" cyclicallylistno
Enable object "Power factor"listno
Send "Power factor" after a changelistno
Send "Power factor" when +/- 0.01 x value [1...100]unsignedInt 1…1005
Send "Power factor" on requestlistno
Send "Power factor" cyclicallylistno
Enable object "Crest factor"listno
Send "Crest factor" after a changelistno
Send "Crest factor" when +/- 0.1 x value [1...100]unsignedInt 1…1005
Send "Crest factor" on requestlistno
Send "Crest factor" cyclicallylistno
A: Monitor active powerunsignedInt 0…10
Send "Active power" when +/- W [1...4,600]unsignedInt 1…46005
Delay for switching in s [0...65,535]unsignedInt 0…655351
Evaluation of threshold 1listonly if contact is closed
Threshold 1 lower limit in W [0...4,600]unsignedInt 0…46005
Threshold 1 upper limit in W [0...4,600]unsignedInt 0…4600100
Contact position when falling below lower limitlistno reaction
Contact position when exceeding upper limitlistno reaction
Evaluation of threshold 2listonly if contact is closed
Threshold 2 lower limit in W [0...4,600]unsignedInt 0…46005
Threshold 2 upper limit in W [0...4,600]unsignedInt 0…4600100
Contact position when falling below lower limitlistno reaction
Contact position when exceeding upper limitlistno reaction
A: Monitor currentunsignedInt 0…10
Send "Current" after a changelistno
Send "Current" when +/- mA [1...20,000]unsignedInt 1…2000050
Send "Current" on requestlistno
Send "Current" cyclicallylistno
Threshold 1 lower limit in 100 mA x value [0...200]unsignedInt 0…2001
Threshold 1 upper limit in 100 mA x value [0...200]unsignedInt 0…2003
Threshold 2 lower limit in 100 mA x value [0...200]unsignedInt 0…200180
Threshold 2 upper limit in 100 mA x value [0...200]unsignedInt 0…200200
A: Monitor voltageunsignedInt 0…10
Send "Voltage" after a changelistno
Send "Voltage" when +/- V [1...265]unsignedInt 1…2655
Send "Voltage" on requestlistno
Send "Voltage" cyclicallylistno
Threshold 1 lower limit in V [95...265]unsignedInt 95…26595
Threshold 1 upper limit in V [95...265]unsignedInt 95…265100
Threshold 2 lower limit in V [95...265]unsignedInt 95…265260
Threshold 2 upper limit in V [95...265]unsignedInt 95…265265
A: Load control slaveunsignedInt 0…10
Load shedding stage output [1...8]unsignedInt 1…81
Load shedding stage can be changed via objectlistno
Overwrite load shedding stage with download or ETS resetlistyes
Slave is controlled vialistexternal object
Enable object "Receive load shedding stage" on "Function"list<--- NOTE
If device is load control master.list<--- NOTE
Object "Deactivate load control" (slave) at recovery of bus voltagelistunchanged
Output BunsignedInt 0…10
B: GeneralunsignedInt 0…10
B: FunctionunsignedInt 0…10
B: TimeunsignedInt 0…10
Delay for switching OFF in s [0...65,535]unsignedInt 0…6553545
Warning time in sec. [0...65,535] add to staircase lighting durationunsignedInt 0…6553545
B: Scenes 1...6unsignedInt 0…10
B: Scenes 7...12unsignedInt 0…10
B: Scenes 13...18unsignedInt 0…10
B: LogicunsignedInt 0…10
B: SafetyunsignedInt 0…10
B: Metering (Wh)unsignedInt 0…10
B: Instrument and power valueslistno
B: Monitor active powerunsignedInt 0…10
B: Monitor currentunsignedInt 0…10
B: Monitor voltageunsignedInt 0…10
B: Load control slaveunsignedInt 0…10
Output CunsignedInt 0…10
C: GeneralunsignedInt 0…10
C: FunctionunsignedInt 0…10
C: TimeunsignedInt 0…10
C: Scenes 1...6unsignedInt 0…10
C: Scenes 7...12unsignedInt 0…10
C: Scenes 13...18unsignedInt 0…10
C: LogicunsignedInt 0…10
C: SafetyunsignedInt 0…10
C: Metering (Wh)unsignedInt 0…10
C: Instrument and power valueslistno
C: Monitor active powerunsignedInt 0…10
C: Monitor currentunsignedInt 0…10
C: Monitor voltageunsignedInt 0…10
C: Load control slaveunsignedInt 0…10
Noteslistno
Notes for SE/SunsignedInt 0…10
To copy and exchange channels start the copy function (rightlist To copy and exchange channels start
Mouse on device in ETS topologylist To copy and exchange channels start
---------------------------------------- This is a "Test text" and shouldlist To copy and exchange channels start
indicate the overall appearance and whether it is easy to read. Letlist To copy and exchange channels start
when another note is now added.list To copy and exchange channels start
indicate the overall appearance and whether it is easy to read. Lets see howlist To copy and exchange channels start

Version history

ApplicationApp noFingerprintFirst seenSizeFile
Switch Measure 3f/1.3a 1.3 latest$A072C45A2026-11-25626 KBDownload

About this file

This is the official ETS product database for the ABB AG - BUSCH-JAEGER SE/S3.16.1 Energy Actuator,3-fold,16/20A,MDRC (6194/19), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.

More from ABB AG - BUSCH-JAEGER

All ABB AG - BUSCH-JAEGER products