LK/S4.2 Linien-/Bereichskoppler,REG 6187-104
ABB AG - BUSCH-JAEGER · Order number 6187-104 · System Infrastructure and Interfacing › Line Couplers
Couple Repeat/2.0a
Download .knxprod Couple Repeat/2.0a 3.0 · 65 KB
Product
| Manufacturer | ABB AG - BUSCH-JAEGER |
|---|---|
| Product name | LK/S4.2 Linien-/Bereichskoppler,REG |
| Order number | 6187-104 |
| Product text | LK/S4.2 Line/Area Coupler,MDRC |
| Hardware | Koppler LK/S4.2 |
| Medium | Twisted Pair |
| Bus current (mA) | 12 |
| Rail mounted | Yes |
| Width (mm) | 36 |
| Device kind | Coupler |
| Registration | Registered |
| Languages | de-DE, en-US |
| Catalog entry | M-0007_H-2CDG.20110.20171.20R0011-1-O0002_HP-A014-30-1868-O0002_CI-6187.2D104-1 |
| Fingerprint | 1868 |
| SHA-256 | c0ceac9459fc2414f62179b3cceb6dc11e2581aebe9a012c2ab1f8f566d35130 |
| First seen | 2026-11-25 |
| Markets | Austria, Belgium, Germany, Netherlands |
Application program: Couple Repeat/2.0a 3.0
| Application number | $A014 |
|---|---|
| Version | 3.0 |
| Mask version | MV-0912 (Coupler 0912) |
| KNX Data Secure | No |
| Minimum ETS version | 4.0 |
| Parameters | 41 |
| Group objects | 0 |
Group objects (0)
| No | Name | Function | Size | DPT | Flags |
|---|
Parameters (24)
| Parameter | Type | Default |
|---|---|---|
| Device function | list | Line/Area Coupler |
| Group telegrams main group 0...13 | list | filter |
| Group telegrams main group 14...31 | list | filter |
| Physically addressed telegrams | list | filter |
| Broadcast telegrams | list | route |
| In case of errors repeat telegrams | list | yes |
| Repeat group addressed telegrams | list | yes |
| Repeat group addressed telegrams | unsignedInt 1…1 | 1 |
| Repeat group addressed telegrams | unsignedInt 0…0 | 0 |
| Repeat physically addressed telegrams | list | yes |
| Physikalisch adressierte Telegramme wiederholen | unsignedInt 1…1 | 1 |
| Physikalisch adressierte Telegramme wiederholen | unsignedInt 0…0 | 0 |
| Repeat broadcast telegrams | list | yes |
| Broadcast Telegramme wiederholen | unsignedInt 1…1 | 1 |
| Broadcast Telegramme wiederholen | unsignedInt 0…0 | 0 |
| Telegram confirmation | list | only if routed |
| In case of errors repeat group addressed telegrams on main line | list | yes |
| In case of errors repeat group addressed telegrams on line | list | yes |
| Dummy_alle GA werden weitergel. | unsignedInt 5…5 | 5 |
| PID_54__NOT_USED_SHALL_BE_0 | unsignedInt 0…0 | 0 |
| PID_55__NOT_USED_SHALL_BE_0 | unsignedInt 0…0 | 0 |
| PID_52__VERSTÄRKER_DUMMY_VALUE | unsignedInt 99…99 | 99 |
| PID_53__VERSTÄRKER_DUMMY_VALUE | unsignedInt 99…99 | 99 |
| If free group address structure is used: Main group 0...13 => 1...28,671 Main group 14...31 => 28,672...65,535 | list | <--- NOTE |
Version history
| Application | App no | Fingerprint | First seen | Size | File |
|---|---|---|---|---|---|
| Couple Repeat/2.0a 3.0 latest | $A014 | 1868 | 2026-11-25 | 65 KB | Download |
About this file
This is the official ETS product database for the ABB AG - BUSCH-JAEGER LK/S4.2 Linien-/Bereichskoppler,REG (6187-104), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.
More from ABB AG - BUSCH-JAEGER
- IPS/S3.5.11 IP Interface Secure,MDRC 2CDG 110 204 R0021
- IPR/S3.1.1 IP Router,MDRC 6186/33
- IPS/S3.1.1 IP Interface,MDRC 6186/35
- IPR/S3.5.11 IP Router Secure,MDRC IPR/S3.5.11
- FCC/S1.1.2.11 Fan Coil Controller,PWM,3-speed,manual operation,MDRC 2CDG 110 211 R0021
- FCC/S1.2.2.11 Fan Coil Controller,0-10V,3-speed,manual operation,MDRC 2CDG 110 213 R0021
- FCC/S1.3.2.11 Fan Coil Controller,0-10V,0-10V,manual operation,MDRC 2CDG 110 215 R0021
- VC/S4.1.11 Valve Drive Controller,4-fold,MDRC 2CDG 110 216 R0021
- VC/S4.2.11 Valve Drive Controller,manual operation,4-fold,MDRC 2CDG 110 217 R0021
- FCC/S1.5.2.11 Fan Coil Controller,PWM,0-10V,manual operation,MDRC 2CDG 110 235 R0021
- SAH/S8.10.7.11 Switch/Shutter Act, 8-f, 10A, MDRC 2CDG 110 247 R0021
- SAH/S16.10.7.11 Switch/Shutter Act, 16-f, 10A, MDRC 2CDG 110 248 R0021