6164/43 Fan Coil-Actuator,1-fold,6A,MDRC 6164/43

ABB AG - BUSCH-JAEGER · Order number 6164/43 · Heizung, Klima, Lüftung › Air-con. actuator

Download .knxprod Fan Coil Actuator/1.0 1.0 · 242 KB

Product

ManufacturerABB AG - BUSCH-JAEGER
Product name6164/43 Fan Coil-Actuator,1-fold,6A,MDRC
Order number6164/43
HardwareFCA/S1.1M
MediumTwisted Pair
Bus current (mA)12
Rail mountedYes
RegistrationRegistered · 2008-07-30
Languagesde-DE, en-US
Catalog entryM-0007_H-2CDG.20110.20084.20R0011-1-O0002_HP-A052-10-9B3B-O0002_CI-6164.2F43-1
Fingerprint9B3B
SHA-25633dbf412c11f73388add421a317cc6f5eca3b99b7641991c4b7b9f469362bd02
First seen2026-11-25
MarketsAustralia

Application program: Fan Coil Actuator/1.0 1.0

Application number$A052
Version1.0
Mask versionMV-0701 (7.1)
KNX Data SecureNo
Parameters308
Group objects81
Group objects (81)
NoNameFunctionSizeDPTFlags
0SystemIn operation1 BitCT
1GeneralRequest status values1 BitCW
2Manual operationEnable/block manual operation1 BitCW
3Manual operationLED On/Off1 BitCW
4Manual operationButton On/Off1 BitCRT
5Manual operationStatus of manual operation1 BitCRT
6Valve HeatingOverload1 BitCT
7Valve CoolingOverload1 BitCT
8Object 8Dummy1 Bit
9Object 9Dummy1 Bit
10FanFan speed switch1 ByteCW
11FanSwitch speed 11 BitCW
11FanSwitch1 BitCW
12FanSwitch speed 21 BitCW
13FanSwitch speed 31 BitCW
14FanFan speed up/down1 BitCW
15FanStatus Fan On/Off1 BitCT
16FanStatus fan speed1 ByteCRT
17FanStatus fan speed 11 BitCRT
18FanStatus fan speed 21 BitCRT
19FanStatus speed 31 BitCRT
20Object 20Dummy1 Bit
21FanLimitation 11 BitCW
22FanLimitation 21 BitCW
23FanLimitation 31 BitCW
24FanLimitation 41 BitCW
25FanForced operation1 BitCW
26FanAutomatic On/Off1 BitCW
27Object 27Dummy1 Bit
28FanStatus automatic1 BitCRT
29FanStatus byte mode1 ByteCRT
30Control inputControl value, Heating/Cooling1 ByteCW
30Control inputControl value, Heating1 ByteCW
31Control inputControl value, Cooling1 ByteCW
31Control inputControl value, Cooling(extra!)1 ByteCW
32Object 32Dummy1 Bit
32Control inputToggle, Heating/Cooling1 BitCW
33Control inputFault control value1 BitCRT
34Object 34Dummy1 Bit
35Valve HeatingBlock1 BitCW
36Valve HeatingForced operation1 BitCW
37Valve HeatingTrigger valve purge1 BitCW
38Valve HeatingStatus valve purge1 BitCRT
39Valve HeatingStatus valve position1 ByteCRT
39Valve HeatingStatus valve position1 BitCRT
40Valve CoolingBlock1 BitCW
41Valve CoolingForced operation1 BitCW
42Valve CoolingTrigger valve purge1 BitCW
43Valve CoolingStatus valve purge1 BitCRT
44Valve CoolingStatus valve position1 ByteCRT
44Valve CoolingStatus valve position1 BitCRT
45OutputSwitch1 BitCW
46OutputPermanent ON1 BitCW
47OutputDisable time function1 BitCW
48OutputChange duration of staircase lighting2 BytesCRW
49OutputStatus switch1 BitCRT
50Input ABlock1 BitCW
51Input ASwitch1 BitCWT
52Input ALong switch operation1 BitCT
53Object 53Dummy1 Bit
54Object 54Dummy1 Bit
55Input BBlock1 BitCW
56Input BSwitch1 BitCWT
57Input BLong switch operation1 BitCT
58Object 58Dummy1 Bit
59Object 59Dummy1 Bit
60Object 60Dummy1 Bit
61Object 61Dummy1 Bit
62Object 62Dummy1 Bit
63Object 63Dummy1 Bit
64Object 64Dummy1 Bit
65Object 65Dummy1 Bit
66Object 66Dummy1 Bit
67Object 67Dummy1 Bit
68Object 68Dummy1 Bit
69Object 69Dummy1 Bit
70Object 70Dummy1 Bit
71Object 71Dummy1 Bit
72Object 72Dummy1 Bit
73Object 73Dummy1 Bit
74Object 74Dummy1 Bit
Parameters (169)
ParameterTypeDefault
Sending and switching delay after bus voltage recovery in s [2...255]unsignedInt 2…2552
Rate of telegramslistnot limited
Send object "in operation"listno
Telegram repeated s [1...65,535]unsignedInt 1…6553560
Send value cyclicallylist0
Enable input A (binary input, contact scanning)listno
Enable input B (binary input, contact scanning)listno
Enable output (switch contact 16 A/10 AX)listno
Enable communication object "Request status values" 1 bitlistno
recall with object valuelist1
Manual operationlistenabled
Reset manual operation to EIB/KNX operationlistno
Enable communication object "Status man. operation" 1 bitlistno
Send object valuelistafter a change
On/OfflistIndication "Status automatic"
Speedlistenabled
Valve Heatinglistenabled
Valve Coolinglistenabled
Input AlistSwitch
Input BlistSwitch
Outputlistenabled
HVAC-Systemlist1 Control value/2-pipe
Toogle Heating/Cooling via objectlist<- Note
Valve cooling independently usablelist<- Note
Toogle Heating/Cooling via automatically control valuelist<- Note
Dummylist
Operation heat/cool after bus voltage recoverylistunchanged
Object value for heating the object "Toggle heating/cooling"list1
Monitoring control values e.g. thermostatlistno
Monitoring time in s [30...65,535]unsignedInt 30…65535120
Send object value (Object "Control value fault" 1 bit)listafter a change
Send object value (Object "Control value fault" 1 bit)list1
Control value after control fault in % [0...100]unsignedInt 0…10030
Fantypelistmulti-level
Dummylist3
Speed on 2 limitlistno
Dummylist1, off
Fan Operation Mode note technical data of Fan !!!listChangeover switch
Fan Operation Mode Note technical data of Fan!!!listChangeover switch
Delay between fan stage switching in ms [50...5,000]unsignedInt 50…5000500
Fan at bus voltage failurelistunchanged
Fan speed on bus voltage failurelistunchanged
Fan at bus voltage recoverylistunchanged
Fan speed on bus voltage recoverylistunchanged
Enable communication object "Forced operation" 1 bitlistno
Forced operation on object valuelist1
Limitation with forced operationlistunchanged
Behaviour with forced operationliston
Enable automatic operationlistyes
Enable direct operationlistno
Time function on ONlistnone
Time in s [1...65,535 x 0.1]unsignedInt 1…655355
Time in s [1...65,535]unsignedInt 1…655355
Starting characteristic of fanlistno
Time function on OFFlistnone
Switch on over fan speedlist3
Time in s [1...65,535 x 0.1]unsignedInt 1…6553520
Time in s [1...65,535]unsignedInt 1…6553520
Minimum dwell period in switch on fan stage in s [1...65,535]unsignedInt 1…655355
Enable communication objects "Status speed x" 1 bitlistno
Meaninglistcurrent fan speed
Send object valueslistafter a change
Enable communication object "Status spedd" 1 bytelistno
Enable communication object "Status byte mode" 1 bitlistno
Enable communication object "Status Fan On/Off" 1 bitlistno
Enable communication object "Status automatic" 1 bitlistno
Dummylistyes
Object value"automatic on/off" switch on to the automaticlist1
Object value "automatic On/Off" switch on to the automaticlist1
Threshold value OFF <-> speed 1 in % [1...100]unsignedInt 1…10010
Threshold value 1 <-> speed 2 in % [1...100]unsignedInt 1…10030
Threshold value OFF <-> ON in % [1...100]unsignedInt 1…10010
Threshold value 2 <-> speed 3 in % [1...100]unsignedInt 1…10070
Threshold value OFF <-> ON in % [1...100]unsignedInt 1…10030
Threshold value OFF <-> ON in % [1...100]unsignedInt 1…10070
Hysteresis threshold value in % +/- [0...20 %]unsignedInt 0…205
Minimum dwell period in fan stage in s [0...65,535]unsignedInt 0…655350
Enable limitationslistno
Speed with limitation 1list3, 2, 1, off
Fan with limitation 1listinactive
Speed with limitation 2listunchanged
Fan with limitation 2listunchanged
Speed with limitation 3list3, 2, 1, off
Fan with limitation 3listinactive
Speed with limitation 4listunchanged
Fan with limitation 4listunchanged
Enable communication objects "Switch speed x" 1 bitlistyes
Enable communication object "Speed up/down" 1 bitlistno
Enable communication object "Switch speed" 1 bytelistno
Valve controllist3-point, opening and closing
Valve typelistde-energised closed
Observe reversing timelist300 ms
Valve position on bus voltage failure in % [0...100]listunchanged
Valve position on bus voltage failurelistclosed
Valve position on bus voltage failurelistopen
Valve position after bus voltage recoverylist
Valve position in % [0...100]unsignedInt 0…1000
Valve position after bus voltage recovery in % [0...100]unsignedInt 1…255255
Cycle time of the PWM in s [10...6,000]unsignedInt 10…6000180
Valve control duration from 0 to 100 % in s [10...6,000]unsignedInt 10…6000180
Valve control duration from 100 to 0% in s [10...6,000]unsignedInt 10…6000180
Correct valve characteristic curvelistno
Automatically adjust valve positionlistno
Number of valve controls up to adjustment [1...65,535]unsignedInt 1…65535100
Enable communication object "Disable" 1 bitlistno
Disable on object valuelist1
Valve position on forced operation in % [0...100]unsignedInt 0…10030
Enable communication object "Valve position status" 1 byte/1 bitlistno
Object value with valver position >0list1
Enable valve purgelistno
Enable communication object "Status valve purge" 1 bitlistno
Duration of valve purge in min. [1...255]unsignedInt 1…25510
Automatic valve purgelistno
Purge cycle in weeks [1...12]unsignedInt 1…126
Reset purge cycle from control value in % [1...99]unsignedInt 1…9999
Value pair 1 Control value in % [0...100]unsignedInt 0…1000
Value pair 2 Control value in % [0...100]unsignedInt 0…100100
Valve position in % [0...100]unsignedInt 0…100100
Further value pairlistno
Value pair 3 Control value in % [0...100]unsignedInt 0…10050
Valve position in % [0...100]unsignedInt 0…10050
Value pair 4 Control value in % [0...100]unsignedInt 0…10050
Ventilstellung bei Busspannungs- wiederkehrlist
Valve position after bus voltage recovery in % [0...100]unsignedInt 0…1000
Valve control duration from 0 to 100% in s [10...6,000]unsignedInt 10…6000180
Control value in % [1...99]unsignedInt 0…1000
Valve position in % [0...100]unsignedInt 0…1000
Control value in % [1...99]unsignedInt 0…100100
Valve position in % [0...100]unsignedInt 0…100100
Value pair 2listno
Control value in % [1...99]unsignedInt 0…10050
Valve position in % [0...100]unsignedInt 0…10050
Value pair 3listno
DummylistSwitch sensor / fault monitoring input
Distinction between long and short operationlistno
Object 1 is activlistyes
Object 3 is inactivlistno
Reaction on closing the contact (rising edge)liston
Reaction on short operationliston
Activate minimum signal time with falling edgelistno
Activate minimum signal time with rising edgelistno
Reaction on opening the contact (falling edge)listoff
Reaction on long operationlistoff
Scan input after download, bus reset and bus voltage recoverylistno
Long operation after ...list0.8 s
Inactive wait state after bus voltage recovery in s [0...30,000]unsignedInt 0…300000
Input is by operationlistclosed
Enable communication object with "Long operation" 1 bitlistno
Object 2 is inactivlistno
Debounce timelist50 ms
Cyclic sending of object "Switch"listno
with object valuelist0 or 1
with object valueunsignedInt 0…30
Telegram repeated in s [1...65,535]unsignedInt 1…6553560
in value x 0.1 s [0...65,535]unsignedInt 1…6553510
Reaction of outputlistnormally opened contact
Contact position on bus voltage failurelistunchanged
Object value "Switch" on bus voltage recoverylistnot write
Enable time functionlistno
Enable communication object "Status switch" 1 bitlistno
Send object value (Object "Status switch")listafter a change
Object value of contact position (Object "Status Switch")list1=closed, 0=open
Value object "Disable Time Function" on bus voltage recoverylist1, i.e. Disable time function
Object value "Disable time function" on bus voltage recoverylist1, i.e. Disable time function
Staircase lighting time in s [1...65,535]unsignedInt 1…6553530
Staircase lighting can be switchedlistON with 1 and OFF with 0
Enable communication object "Change duration of staircase lighting" 2 bytelistno
Enable communication object "Permanent ON" 1 bitlistno
Restart of staircase time after end of permanent ONlistno

Version history

ApplicationApp noFingerprintFirst seenSizeFile
Fan Coil Actuator/1.0 1.0 latest$A0529B3B2026-11-25242 KBDownload

About this file

This is the official ETS product database for the ABB AG - BUSCH-JAEGER 6164/43 Fan Coil-Actuator,1-fold,6A,MDRC (6164/43), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.