KNX Database

6136/07-8xx Smart Touch 7 6136/07-8xx

ABB AG - BUSCH-JAEGER · Order number 6136/07-8xx · Display › LCD-Display

Download .knxprod SmartTouch 7 DCA/3.2 3.2 · 539 KB

Product

ManufacturerABB AG - BUSCH-JAEGER
Product name6136/07-8xx Smart Touch 7
Order number6136/07-8xx
Product text6136/07-8xx Busch-SmartTouch 7
Hardware6136/07-8xx Busch-SmartTouch 7
MediumTwisted Pair
Bus current (mA)10
Rail mountedNo
RegistrationRegistered · 2020-09-11
Languagesen-US
Catalog entryM-0007_H-6136.2F07.2D8xx-3_HP-6136-32-8B05-6136-33-C695_CI-6136.2F07.2D8xx-1
Fingerprint8B05
SHA-256d657f82b2936fc3ee8f0cdb240768c35092ae7d6e14d15116d9a3d97c8c9660d
First seen2026-11-25
MarketsAustria, Belgium, Germany, Netherlands

Application program: SmartTouch 7 DCA/3.2 3.2

Application number$6136
Version3.2
Mask versionMV-07B0 (System B)
KNX Data SecureNo
Minimum ETS version5.0
Parameters4489
Group objects757
Group objects (757)
NoNameFunctionSizeDPTFlags
0Message 1 [1 bit]input/output1 Bit1.5 alarmCWTU
0Message 1 [14 bytes]input14 Bytes16.1 Character String (ISO 8859-1)CWTU
0OutputOutput1 Bit1.1 switchCRT
0OutputOutput1 Byte5.1 percentage (0..100%)CRT
0Control inputinput1 Bit1.3 enableCWU
0Inputinput1 Bit1.10 start/stopCWU
0Inputinput1 Byte5.10 counter pulses (0..255)CWU
0Input 1input2 Bytes9.1 temperature (°C)CWU
0Input 1 (LSB)input1 Bit1.2 booleanCWU
0Inputinput2 Bytes7.1 pulsesCWU
0Inputinput1 Bit1.1 switchCWU
0Object 1 [send]output1 Bit1.1 switchCT
0Object 1 [send]output1 Bit1.8 up/downCT
0Object 1 [send]output2 Bit2.3 enable controlCT
0Object 1 [send]output1 Byte5.1 percentage (0..100%)CT
0Object 1 [send]output1 Byte5.10 counter pulses (0..255)CT
0Object 1 [send]output3 Bytes232.600 RGB value 3x(0..255)CT
0Object 1 [send]output1 Byte18.1 scene controlCT
0Object 1 [send]output1 Byte20.102 HVAC modeCT
0Object 1 [send]output2 Bytes9.1 temperature (°C)CT
0Object 1 [send]output14 Bytes16.1 Character String (ISO 8859-1)CT
0Value 1 [send]output/input1 Bit1.1 switchCWTU
0Value 1 [send]output/input2 Bit2.1 switch controlCWTU
0Value 1 [send]output/input1 Byte5.1 percentage (0..100%)CWTU
0Value 1 [send]output/input1 Byte5.10 counter pulses (0..255)CWTU
0Value 1 [send]output/input1 Byte6.10 counter pulses (-128..127)CWTU
0Value 1 [send]output/input1 Byte18.1 scene controlCWTU
0Value 1 [send]output/input1 Byte20.102 HVAC modeCWTU
0Value 1 [send]output/input2 Bytes9.1 temperature (°C)CWTU
0Value 1 [send]output/input2 Bytes8.1 pulses differenceCWTU
0Value 1 [send]output/input2 Bytes7.1 pulsesCWTU
0Value 1 [send]output/input4 Bytes13.1 counter pulses (signed)CWTU
0Value 1 [send]output/input4 Bytes12.1 counter pulses (unsigned)CWTU
0Value 1 [send]output/input14 Bytes16.1 Character String (ISO 8859-1)CWTU
0Value [send]output/input1 Bit1.1 switchCWTU
0Value [send]output/input2 Bit2.1 switch controlCWTU
0Value [send]output/input1 Byte5.1 percentage (0..100%)CWTU
0Value [send]output/input1 Byte5.10 counter pulses (0..255)CWTU
0Value [send]output/input1 Byte6.10 counter pulses (-128..127)CWTU
0Value [send]output/input1 Byte18.1 scene controlCWTU
0Value [send]output/input1 Byte20.102 HVAC modeCWTU
0Value [send]output/input2 Bytes9.1 temperature (°C)CWTU
0Value [send]output/input2 Bytes8.1 pulses differenceCWTU
0Value [send]output/input2 Bytes7.1 pulsesCWTU
0Value [send]output/input4 Bytes13.1 counter pulses (signed)CWTU
0Value [send]output/input4 Bytes12.1 counter pulses (unsigned)CWTU
0Value [send]output/input14 Bytes16.1 Character String (ISO 8859-1)CWTU
0Switchoutput/input1 Bit1.1 switchCWTU
0Switch RGBoutput/input1 Bit1.1 switchCWTU
0Value [1 Byte] signedoutput/input1 Byte6.10 counter pulses (-128..127)CWTU
0Value [1 Byte] unsignedoutput/input1 Byte5.1 percentage (0..100%)CWTU
0Value [1 Byte] unsignedoutput/input1 Byte5.10 counter pulses (0..255)CWTU
0Value [2 Byte] signedoutput/input2 Bytes8.1 pulses differenceCWTU
0Value [2 Byte] unsignedoutput/input2 Bytes7.1 pulsesCWTU
0Value [2 Byte] floatoutput/input2 Bytes9.1 temperature (°C)CWTU
0Value [4 Byte] signedoutput/input4 Bytes13.1 counter pulses (signed)CWTU
0Value [4 Byte] unsignedoutput/input4 Bytes12.1 counter pulses (unsigned)CWTU
0Move UP/DOWNoutput/input1 Bit1.8 up/downCWTU
0Output 1output/input1 Bit1.2 booleanCWTU
0Scene number 1output/input1 Byte18.1 scene controlCWTU
0Value inputinput1 Bit1.1 switchCWU
0Value inputinput1 Byte5.1 percentage (0..100%)CWU
0Value inputinput1 Byte5.10 counter pulses (0..255)CWU
0Value inputinput1 Byte6.10 counter pulses (-128..127)CWU
0Value inputinput2 Bytes7.1 pulsesCWU
0Value inputinput2 Bytes8.1 pulses differenceCWU
0Value inputinput2 Bytes9.1 temperature (°C)CWU
0Value inputinput4 Bytes12.1 counter pulses (unsigned)CWU
0Value inputinput4 Bytes13.1 counter pulses (signed)CWU
0Value inputinput14 Bytes16.0 Character String (ASCII)CWU
0Wind speedinput2 Bytes9.5 speed (m/s)CWU
0Temperatureinput2 Bytes9.1 temperature (°C)CWU
0Raininput1 Bit1.2 booleanCWU
0Twilightinput2 Bytes9.4 lux (Lux)CWU
0Brightnessinput2 Bytes9.4 lux (Lux)CWU
0CO2input2 Bytes9.8 parts/million (ppm)CWU
0Humidityinput2 Bytes9.7 humidity (%)CWU
0Air-pressureinput2 Bytes9.6 pressure (Pa)CWU
0Control On/Off (slave)input1 Bit1.1 switchCWTU
0Disableinput1 Bit1.2 booleanCWU
0Titleinput14 Bytes16.0 Character String (ASCII)CWU
1Ringtone Volumeinput/output1 Byte5.1 percentage (0..100%)CWTU
1Acknowledge message 1 [14 bytes]output14 Bytes16.1 Character String (ISO 8859-1)CWTU
1Input 1Input1 Bit1.1 switchCWU
1Input 1Input1 Byte5.1 percentage (0..100%)CWU
1Input 1input1 Bit1.1 switchCWU
1Input 1input1 Byte5.10 counter pulses (0..255)CWU
1Input 1input2 Bytes9.1 temperature (°C)CWU
1Output 1output1 Bit1.1 switchCT
1Output 1output1 Byte5.1 percentage (0..100%)CT
1Inputinput/output1 Bit1.1 switchCWU
1Inputinput/output2 Bit2.1 switch controlCWU
1Inputinput/output1 Byte5.1 percentage (0..100%)CWU
1Inputinput/output1 Byte5.10 counter pulses (0..255)CWU
1Inputinput/output1 Byte6.10 counter pulses (-128..127)CWU
1Inputinput/output1 Byte18.1 scene controlCWU
1Inputinput/output1 Byte20.102 HVAC modeCWU
1Inputinput/output2 Bytes9.1 temperature (°C)CWU
1Inputinput/output2 Bytes8.1 pulses differenceCWU
1Inputinput/output2 Bytes7.1 pulsesCWU
1Inputinput/output4 Bytes13.1 counter pulses (signed)CWU
1Inputinput/output4 Bytes12.1 counter pulses (unsigned)CWU
1Inputinput/output14 Bytes16.1 Character String (ISO 8859-1)CWU
1Input 2input2 Bytes9.1 temperature (°C)CWU
1Input 2input1 Bit1.2 booleanCWU
1Outputoutput1 Bit1.1 switchCWTU
1Object 1 [receive]input1 Bit1.1 switchCWTU
1Object 1 [receive]input1 Bit1.8 up/downCWTU
1Object 1 [receive]input2 Bit2.3 enable controlCWTU
1Object 1 [receive]input1 Byte5.1 percentage (0..100%)CWTU
1Object 1 [receive]input1 Byte5.10 counter pulses (0..255)CWTU
1Object 1 [receive]input3 Bytes232.600 RGB value 3x(0..255)CWTU
1Object 1 [receive]input1 Byte18.1 scene controlCWTU
1Object 1 [receive]input1 Byte20.102 HVAC modeCWTU
1Object 1 [receive]input2 Bytes9.1 temperature (°C)CWTU
1Object 1 [receive]input14 Bytes16.1 Character String (ISO 8859-1)CWTU
1Status value [receive]input1 Bit1.1 switchCWU
1Status value [receive]input1 Bit1.1 switchCWU
1Dimmingoutput4 Bit3.7 dimming controlCT
1Valueoutput/input1 Byte5.1 percentage (0..100%)CWTU
1Switch Whiteoutput/input1 Bit1.1 switchCWTU
1Status [1 Byte] signedinput1 Byte6.10 counter pulses (-128..127)CWU
1Status [1 Byte] unsignedinput1 Byte5.1 percentage (0..100%)CWU
1Status [1 Byte] unsignedinput1 Byte5.10 counter pulses (0..255)CWU
1Status [2 Byte] signedinput2 Bytes8.1 pulses differenceCWU
1Status [2 Byte] unsignedinput2 Bytes7.1 pulsesCWU
1Status [2 Byte] floatinput2 Bytes9.1 temperature (°C)CWU
1Status [4 Byte] signedinput4 Bytes13.1 counter pulses (signed)CWU
1Status [4 Byte] unsignedinput4 Bytes12.1 counter pulses (unsigned)CWU
1STOP/ Slat adjustmentoutput/input1 Bit1.8 up/downCWTU
1Output 2output/input1 Bit1.2 booleanCWTU
1Scene number 2output/input1 Byte18.1 scene controlCWTU
1Switch Alarminput1 Bit1.1 switchCWU
1Actual temperatureoutput2 Bytes9.1 temperature (°C)CT
1Artistinput14 Bytes16.0 Character String (ASCII)CWU
2Increase/decrease ringtone volumeinput4 Bit3.7 dimming controlCWU
2Acknowledge message 1 [1 bit]input/output1 Bit1.16 acknowledgeCWTU
2Input 2Input1 Bit1.1 switchCWU
2Input 2Input1 Byte5.1 percentage (0..100%)CWU
2Input 2input1 Bit1.1 switchCWU
2Input 2input1 Byte5.10 counter pulses (0..255)CWU
2Input 2input2 Bytes9.1 temperature (°C)CWU
2Output 2output1 Bit1.1 switchCT
2Output 2output1 Byte5.1 percentage (0..100%)CT
2Outputinput/output1 Bit1.1 switchCWTU
2Outputinput/output2 Bit2.1 switch controlCWTU
2Outputinput/output1 Byte5.1 percentage (0..100%)CWTU
2Outputinput/output1 Byte5.10 counter pulses (0..255)CWTU
2Outputinput/output1 Byte6.10 counter pulses (-128..127)CWTU
2Outputinput/output1 Byte18.1 scene controlCWTU
2Outputinput/output1 Byte20.102 HVAC modeCWTU
2Outputinput/output2 Bytes9.1 temperature (°C)CWTU
2Outputinput/output2 Bytes8.1 pulses differenceCWTU
2Outputinput/output2 Bytes7.1 pulsesCWTU
2Outputinput/output4 Bytes13.1 counter pulses (signed)CWTU
2Outputinput/output4 Bytes12.1 counter pulses (unsigned)CWTU
2Outputinput/output14 Bytes16.1 Character String (ISO 8859-1)CWTU
2Outputoutput1 Bit1.1 switchCWTU
2Outputoutput1 Byte5.10 counter pulses (0..255)CWTU
2Input 3input1 Bit1.2 booleanCWU
2Staire case light time [s]input2 Bytes7.5 time (s)CWTU
2Object 2 [send]output1 Bit1.1 switchCT
2Object 2 [send]output1 Bit1.8 up/downCT
2Object 2 [send]output2 Bit2.3 enable controlCT
2Object 2 [send]output1 Byte5.1 percentage (0..100%)CT
2Object 2 [send]output1 Byte5.10 counter pulses (0..255)CT
2Object 2 [send]output3 Bytes232.600 RGB value 3x(0..255)CT
2Object 2 [send]output1 Byte18.1 scene controlCT
2Object 2 [send]output1 Byte20.102 HVAC modeCT
2Object 2 [send]output2 Bytes9.1 temperature (°C)CT
2Value 2 [send]output1 Bit1.1 switchCT
2Value 2 [send]output2 Bit2.3 enable controlCT
2Value 2 [send]output1 Byte5.1 percentage (0..100%)CT
2Value 2 [send]output1 Byte5.10 counter pulses (0..255)CT
2Value 2 [send]output1 Byte6.10 counter pulses (-128..127)CT
2Value 2 [send]output1 Byte18.1 scene controlCT
2Value 2 [send]output1 Byte20.102 HVAC modeCT
2Value 2 [send]output2 Bytes9.1 temperature (°C)CT
2Value 2 [send]output2 Bytes8.1 pulses differenceCT
2Value 2 [send]output2 Bytes7.1 pulsesCT
2Value 2 [send]output4 Bytes13.1 counter pulses (signed)CT
2Value 2 [send]output4 Bytes12.1 counter pulses (unsigned)CT
2Value 2 [send]output14 Bytes16.1 Character String (ISO 8859-1)CT
2Disableinput1 Bit1.2 booleanCWU
2Valueoutput/input1 Byte5.1 percentage (0..100%)CWTU
2Status Switchinput1 Bit1.1 switchCWU
2Switchoutput/input1 Bit1.1 switchCWTU
2Status positioninput1 Bit1.2 booleanCWU
2Output 3output/input1 Bit1.2 booleanCWTU
2Scene number 3output/input1 Byte18.1 scene controlCWTU
2Switch Warninginput1 Bit1.1 switchCWU
2External actual temperatureinput2 Bytes9.1 temperature (°C)CWTU
2Albuminput14 Bytes16.0 Character String (ASCII)CWU
3Speech Volumeinput/output1 Byte5.1 percentage (0..100%)CWTU
3Input 3Input1 Bit1.1 switchCWU
3Input 3Input1 Byte5.1 percentage (0..100%)CWU
3Outputoutput1 Bit1.1 switchCT
3Outputoutput1 Byte5.10 counter pulses (0..255)CT
3Outputoutput2 Bytes9.1 temperature (°C)CT
3Output 3output1 Bit1.1 switchCT
3Output 3output1 Byte5.1 percentage (0..100%)CT
3Input 4input1 Bit1.2 booleanCWU
3Switch on delay time [s]input2 Bytes7.5 time (s)CWTU
3Object 2 [receive]input1 Bit1.1 switchCWTU
3Object 2 [receive]input1 Bit1.8 up/downCWTU
3Object 2 [receive]input2 Bit2.3 enable controlCWTU
3Object 2 [receive]input1 Byte5.1 percentage (0..100%)CWTU
3Object 2 [receive]input1 Byte5.10 counter pulses (0..255)CWTU
3Object 2 [receive]input3 Bytes232.600 RGB value 3x(0..255)CWTU
3Object 2 [receive]input1 Byte18.1 scene controlCWTU
3Object 2 [receive]input1 Byte20.102 HVAC modeCWTU
3Object 2 [receive]input2 Bytes9.1 temperature (°C)CWTU
3Disableinput1 Bit1.2 booleanCWU
3Status Switchinput1 Bit1.1 switchCWU
3Status Valueinput1 Byte5.1 percentage (0..100%)CWU
3Switchoutput/input1 Bit1.1 switchCWTU
3Status upper end positioninput1 Bit1.2 booleanCWU
3Output 4output/input1 Bit1.2 booleanCWTU
3Scene number 4output/input1 Byte18.1 scene controlCWTU
3Switch Informationinput1 Bit1.1 switchCWU
3Fault, actual temperature (slave)input/output1 Bit1.1 switchCWU
3Playoutput/input1 Bit1.2 booleanCWTU
3Playoutput/input1 Byte5.10 counter pulses (0..255)CWTU
4Increase/decrease speech volumeinput4 Bit3.7 dimming controlCWU
4Input 4Input1 Bit1.1 switchCWU
4Input 4Input1 Byte5.1 percentage (0..100%)CWU
4Output 4output1 Bit1.1 switchCT
4Output 4output1 Byte5.1 percentage (0..100%)CT
4Outputoutput14 Bytes16.1 Character String (ISO 8859-1)CWTU
4Output 1 (LSB)output1 Bit1.2 booleanCWTU
4Switch off delay time [s]input2 Bytes7.5 time (s)CWTU
4Object 3 [send]output1 Bit1.1 switchCT
4Object 3 [send]output1 Bit1.8 up/downCT
4Object 3 [send]output2 Bit2.3 enable controlCT
4Object 3 [send]output1 Byte5.1 percentage (0..100%)CT
4Object 3 [send]output1 Byte5.10 counter pulses (0..255)CT
4Object 3 [send]output3 Bytes232.600 RGB value 3x(0..255)CT
4Object 3 [send]output1 Byte18.1 scene controlCT
4Object 3 [send]output1 Byte20.102 HVAC modeCT
4Object 3 [send]output2 Bytes9.1 temperature (°C)CT
4Status Valueinput1 Byte5.1 percentage (0..100%)CWU
4Disableinput1 Bit1.2 booleanCWU
4Value Redoutput/input1 Byte5.10 counter pulses (0..255)CWTU
4Status lower end positioninput1 Bit1.2 booleanCWU
4Output 5output/input1 Bit1.2 booleanCWTU
4Scene number 5output/input1 Byte18.1 scene controlCWTU
4Operation mode (slave)output1 Byte20.102 HVAC modeCWTU
4Pauseoutput/input1 Bit1.2 booleanCWTU
4Pauseoutput/input1 Byte5.10 counter pulses (0..255)CWTU
5Ringingoutput1 Bit1.1 switchCT
5Input 5Input1 Bit1.1 switchCWU
5Input 5Input1 Byte5.1 percentage (0..100%)CWU
5Output 5output1 Bit1.1 switchCT
5Output 5output1 Byte5.1 percentage (0..100%)CT
5Output 2output1 Bit1.2 booleanCWTU
5Object 3 [receive]input1 Bit1.1 switchCWTU
5Object 3 [receive]input1 Bit1.8 up/downCWTU
5Object 3 [receive]input2 Bit2.3 enable controlCWTU
5Object 3 [receive]input1 Byte5.1 percentage (0..100%)CWTU
5Object 3 [receive]input1 Byte5.10 counter pulses (0..255)CWTU
5Object 3 [receive]input3 Bytes232.600 RGB value 3x(0..255)CWTU
5Object 3 [receive]input1 Byte18.1 scene controlCWTU
5Object 3 [receive]input1 Byte20.102 HVAC modeCWTU
5Object 3 [receive]input2 Bytes9.1 temperature (°C)CWTU
5Disableinput1 Bit1.2 booleanCWU
5Value Greenoutput/input1 Byte5.10 counter pulses (0..255)CWTU
5Status height [0..255]input1 Byte5.10 counter pulses (0..255)CWU
5Output 6output/input1 Bit1.2 booleanCWTU
5Scene number 6output/input1 Byte18.1 scene controlCWTU
5Superimposed operation mode (master/slave)input/output1 Byte20.102 HVAC modeCWTU
5Stopoutput/input1 Bit1.2 booleanCWTU
5Stopoutput/input1 Byte5.10 counter pulses (0..255)CWTU
6Call startedoutput1 Bit1.1 switchCT
6Input 6Input1 Bit1.1 switchCWU
6Input 6Input1 Byte5.1 percentage (0..100%)CWU
6Output 6output1 Bit1.1 switchCT
6Output 6output1 Byte5.1 percentage (0..100%)CT
6Output 3output1 Bit1.2 booleanCWTU
6Object 4 [send]output1 Bit1.1 switchCT
6Object 4 [send]output1 Bit1.8 up/downCT
6Object 4 [send]output2 Bit2.3 enable controlCT
6Object 4 [send]output1 Byte5.1 percentage (0..100%)CT
6Object 4 [send]output1 Byte5.10 counter pulses (0..255)CT
6Object 4 [send]output3 Bytes232.600 RGB value 3x(0..255)CT
6Object 4 [send]output1 Byte18.1 scene controlCT
6Object 4 [send]output1 Byte20.102 HVAC modeCT
6Object 4 [send]output2 Bytes9.1 temperature (°C)CT
6Value Blueoutput/input1 Byte5.10 counter pulses (0..255)CWTU
6Status height [0..100%]input1 Byte5.1 percentage (0..100%)CWU
6Output 7output/input1 Bit1.2 booleanCWTU
6Scene number 7output/input1 Byte18.1 scene controlCWTU
6Window contact (master/slave)input/output1 Bit1.19 window/doorCWTU
6Skip forwardoutput/input1 Bit1.2 booleanCWTU
6Skip forwardoutput/input1 Byte5.10 counter pulses (0..255)CWTU
7Call endedoutput1 Bit1.1 switchCT
7Input 7Input1 Bit1.1 switchCWU
7Input 7Input1 Byte5.1 percentage (0..100%)CWU
7Output 7output1 Bit1.1 switchCT
7Output 7output1 Byte5.1 percentage (0..100%)CT
7Output 4output1 Bit1.2 booleanCWTU
7Object 4 [receive]input1 Bit1.1 switchCWTU
7Object 4 [receive]input1 Bit1.8 up/downCWTU
7Object 4 [receive]input2 Bit2.3 enable controlCWTU
7Object 4 [receive]input1 Byte5.1 percentage (0..100%)CWTU
7Object 4 [receive]input1 Byte5.10 counter pulses (0..255)CWTU
7Object 4 [receive]input3 Bytes232.600 RGB value 3x(0..255)CWTU
7Object 4 [receive]input1 Byte18.1 scene controlCWTU
7Object 4 [receive]input1 Byte20.102 HVAC modeCWTU
7Object 4 [receive]input2 Bytes9.1 temperature (°C)CWTU
7Value RGB [3 byte]output/input3 Bytes232.600 RGB value 3x(0..255)CWTU
7Wind alarminput1 Bit1.5 alarmCWU
7Output 8output/input1 Bit1.2 booleanCWTU
7Scene number 8output/input1 Byte18.1 scene controlCWTU
7Presence detector (master/slave)input/output1 Bit1.18 occupancyCWTU
7Skip backwardoutput/input1 Bit1.2 booleanCWTU
7Skip backwardoutput/input1 Byte5.10 counter pulses (0..255)CWTU
8Mute incoming callsinput/output1 Bit1.1 switchCWTU
8Input 8Input1 Bit1.1 switchCWU
8Input 8Input1 Byte5.1 percentage (0..100%)CWU
8Output 8output1 Bit1.1 switchCT
8Output 8output1 Byte5.1 percentage (0..100%)CT
8Output 5output1 Bit1.2 booleanCWTU
8Object 5 [send]output1 Bit1.1 switchCT
8Object 5 [send]output1 Bit1.8 up/downCT
8Object 5 [send]output2 Bit2.3 enable controlCT
8Object 5 [send]output1 Byte5.1 percentage (0..100%)CT
8Object 5 [send]output1 Byte5.10 counter pulses (0..255)CT
8Object 5 [send]output3 Bytes232.600 RGB value 3x(0..255)CT
8Object 5 [send]output1 Byte18.1 scene controlCT
8Object 5 [send]output1 Byte20.102 HVAC modeCT
8Object 5 [send]output2 Bytes9.1 temperature (°C)CT
8Value Whiteoutput/input1 Byte5.10 counter pulses (0..255)CWTU
8Disableinput1 Bit1.2 booleanCWU
8Output stepsoutput/input1 Byte5.10 counter pulses (0..255)CWTU
8Scene number 9output/input1 Byte18.1 scene controlCWTU
8Fan coil manual (slave)input/output1 Bit1.11 stateCWTU
8Muteoutput/input1 Bit1.2 booleanCWTU
8Muteoutput/input1 Byte5.10 counter pulses (0..255)CWTU
9Block all timeprogramsinput1 Bit1.3 enableCWU
9Input 9Input1 Bit1.1 switchCWU
9Input 9Input1 Byte5.1 percentage (0..100%)CWU
9Output 9output1 Bit1.1 switchCT
9Output 9output1 Byte5.1 percentage (0..100%)CT
9Output 6output1 Bit1.2 booleanCWTU
9Object 5 [receive]input1 Bit1.1 switchCWTU
9Object 5 [receive]input1 Bit1.8 up/downCWTU
9Object 5 [receive]input2 Bit2.3 enable controlCWTU
9Object 5 [receive]input1 Byte5.1 percentage (0..100%)CWTU
9Object 5 [receive]input1 Byte5.10 counter pulses (0..255)CWTU
9Object 5 [receive]input3 Bytes232.600 RGB value 3x(0..255)CWTU
9Object 5 [receive]input1 Byte18.1 scene controlCWTU
9Object 5 [receive]input1 Byte20.102 HVAC modeCWTU
9Object 5 [receive]input2 Bytes9.1 temperature (°C)CWTU
9Value Cold Whiteoutput/input1 Byte5.10 counter pulses (0..255)CWTU
9Disableinput1 Bit1.2 booleanCWU
9Scene number 10output/input1 Byte18.1 scene controlCWTU
9Condensate water alarm (master/slave)input/output1 Bit1.5 alarmCWTU
9Volume upoutput/input1 Bit1.2 booleanCWTU
10Activate vacationinput1 Bit1.10 start/stopCWU
10Input 10Input1 Bit1.1 switchCWU
10Input 10Input1 Byte5.1 percentage (0..100%)CWU
10Output 10output1 Bit1.1 switchCT
10Output 10output1 Byte5.1 percentage (0..100%)CT
10Output 7output1 Bit1.2 booleanCWTU
10Object 6 [send]output1 Bit1.1 switchCT
10Object 6 [send]output1 Bit1.8 up/downCT
10Object 6 [send]output2 Bit2.3 enable controlCT
10Object 6 [send]output1 Byte5.1 percentage (0..100%)CT
10Object 6 [send]output1 Byte5.10 counter pulses (0..255)CT
10Object 6 [send]output3 Bytes232.600 RGB value 3x(0..255)CT
10Object 6 [send]output1 Byte18.1 scene controlCT
10Object 6 [send]output1 Byte20.102 HVAC modeCT
10Object 6 [send]output2 Bytes9.1 temperature (°C)CT
10Value Warm Whiteoutput/input1 Byte5.10 counter pulses (0..255)CWTU
10Disableinput1 Bit1.2 booleanCWU
10Units switchover (slave)input/output1 Bit1.1 switchCWTU
10Volume downoutput/input1 Bit1.2 booleanCWTU
11Status vacationoutput1 Bit1.10 start/stopCWTU
11Output 8 (MSB)output1 Bit1.2 booleanCWTU
11Output 8output1 Bit1.2 booleanCWTU
11Object 6 [receive]input1 Bit1.1 switchCWTU
11Object 6 [receive]input1 Bit1.8 up/downCWTU
11Object 6 [receive]input2 Bit2.3 enable controlCWTU
11Object 6 [receive]input1 Byte5.1 percentage (0..100%)CWTU
11Object 6 [receive]input1 Byte5.10 counter pulses (0..255)CWTU
11Object 6 [receive]input3 Bytes232.600 RGB value 3x(0..255)CWTU
11Object 6 [receive]input1 Byte18.1 scene controlCWTU
11Object 6 [receive]input1 Byte20.102 HVAC modeCWTU
11Object 6 [receive]input2 Bytes9.1 temperature (°C)CWTU
11Value Brightnessoutput/input1 Byte5.10 counter pulses (0..255)CWTU
11On/off request (slave)output1 Bit1.1 switchCT
11Volumeoutput/input4 Bit3.7 dimming controlCWTU
11Volumeoutput/input1 Byte5.1 percentage (0..100%)CWTU
12Dateoutput3 Bytes11.1 dateCWTU
12Dateinput3 Bytes11.1 dateCWTU
12Output 9output1 Bit1.2 booleanCWTU
12Object 7 [send]output1 Bit1.1 switchCT
12Object 7 [send]output1 Bit1.8 up/downCT
12Object 7 [send]output2 Bit2.3 enable controlCT
12Object 7 [send]output1 Byte5.1 percentage (0..100%)CT
12Object 7 [send]output1 Byte5.10 counter pulses (0..255)CT
12Object 7 [send]output3 Bytes232.600 RGB value 3x(0..255)CT
12Object 7 [send]output1 Byte18.1 scene controlCT
12Object 7 [send]output1 Byte20.102 HVAC modeCT
12Object 7 [send]output2 Bytes9.1 temperature (°C)CT
12Value Temperatureoutput/input1 Byte5.10 counter pulses (0..255)CWTU
12Setpoint display (slave)input/output2 Bytes9.1 temperature (°C)CWTU
12On/Offoutput/input1 Bit1.2 booleanCWTU
12On/Offoutput/input1 Byte5.10 counter pulses (0..255)CWTU
13Timeoutput3 Bytes10.1 time of dayCWTU
13Timeinput3 Bytes10.1 time of dayCWTU
13Output 10output1 Bit1.2 booleanCWTU
13Object 7 [receive]input1 Bit1.1 switchCWTU
13Object 7 [receive]input1 Bit1.8 up/downCWTU
13Object 7 [receive]input2 Bit2.3 enable controlCWTU
13Object 7 [receive]input1 Byte5.1 percentage (0..100%)CWTU
13Object 7 [receive]input1 Byte5.10 counter pulses (0..255)CWTU
13Object 7 [receive]input3 Bytes232.600 RGB value 3x(0..255)CWTU
13Object 7 [receive]input1 Byte18.1 scene controlCWTU
13Object 7 [receive]input1 Byte20.102 HVAC modeCWTU
13Object 7 [receive]input2 Bytes9.1 temperature (°C)CWTU
13Disableinput1 Bit1.2 booleanCWU
13Request setpoint (slave)output1 Byte6.10 counter pulses (-128..127)CT
13Source 1output/input1 Bit1.2 booleanCWTU
13Source 1output/input1 Byte5.10 counter pulses (0..255)CWTU
14Display brightnessinput1 Byte5.1 percentage (0..100%)CWU
14Output 11output1 Bit1.2 booleanCWTU
14Object 8 [send]output1 Bit1.1 switchCT
14Object 8 [send]output1 Bit1.8 up/downCT
14Object 8 [send]output2 Bit2.3 enable controlCT
14Object 8 [send]output1 Byte5.1 percentage (0..100%)CT
14Object 8 [send]output1 Byte5.10 counter pulses (0..255)CT
14Object 8 [send]output3 Bytes232.600 RGB value 3x(0..255)CT
14Object 8 [send]output1 Byte18.1 scene controlCT
14Object 8 [send]output1 Byte20.102 HVAC modeCT
14Object 8 [send]output2 Bytes9.1 temperature (°C)CT
14Confirm setpoint (slave)input/output1 Byte6.10 counter pulses (-128..127)CWTU
14Source 2output/input1 Bit1.2 booleanCWTU
14Source 2output/input1 Byte5.10 counter pulses (0..255)CWTU
15Backlight on/offinput1 Bit1.1 switchCWU
15Output 12output1 Bit1.2 booleanCWTU
15Object 8 [receive]input1 Bit1.1 switchCWTU
15Object 8 [receive]input1 Bit1.8 up/downCWTU
15Object 8 [receive]input2 Bit2.3 enable controlCWTU
15Object 8 [receive]input1 Byte5.1 percentage (0..100%)CWTU
15Object 8 [receive]input1 Byte5.10 counter pulses (0..255)CWTU
15Object 8 [receive]input3 Bytes232.600 RGB value 3x(0..255)CWTU
15Object 8 [receive]input1 Byte18.1 scene controlCWTU
15Object 8 [receive]input1 Byte20.102 HVAC modeCWTU
15Object 8 [receive]input2 Bytes9.1 temperature (°C)CWTU
15Heating/cooling request (slave)output1 Bit1.100 cooling/heatingCT
15Source 3output/input1 Bit1.2 booleanCWTU
15Source 3output/input1 Byte5.10 counter pulses (0..255)CWTU
16Backlight statusoutput1 Bit1.1 switchCT
16Output 13output1 Bit1.2 booleanCWTU
16Object 9 [send]output1 Bit1.1 switchCT
16Object 9 [send]output1 Bit1.8 up/downCT
16Object 9 [send]output2 Bit2.3 enable controlCT
16Object 9 [send]output1 Byte5.1 percentage (0..100%)CT
16Object 9 [send]output1 Byte5.10 counter pulses (0..255)CT
16Object 9 [send]output3 Bytes232.600 RGB value 3x(0..255)CT
16Object 9 [send]output1 Byte18.1 scene controlCT
16Object 9 [send]output1 Byte20.102 HVAC modeCT
16Object 9 [send]output2 Bytes9.1 temperature (°C)CT
16Request fan speed level manual (slave)output1 Bit1.1 switchCT
16Source 4output/input1 Bit1.2 booleanCWTU
16Source 4output/input1 Byte5.10 counter pulses (0..255)CWTU
17Screensaver on/offinput1 Bit1.1 switchCWU
17Output 14output1 Bit1.2 booleanCWTU
17Object 9 [receive]input1 Bit1.1 switchCWTU
17Object 9 [receive]input1 Bit1.8 up/downCWTU
17Object 9 [receive]input2 Bit2.3 enable controlCWTU
17Object 9 [receive]input1 Byte5.1 percentage (0..100%)CWTU
17Object 9 [receive]input1 Byte5.10 counter pulses (0..255)CWTU
17Object 9 [receive]input3 Bytes232.600 RGB value 3x(0..255)CWTU
17Object 9 [receive]input1 Byte18.1 scene controlCWTU
17Object 9 [receive]input1 Byte20.102 HVAC modeCWTU
17Object 9 [receive]input2 Bytes9.1 temperature (°C)CWTU
17Request fan speed level (slave)output1 Byte6.10 counter pulses (-128..127)CT
17Source 5output/input1 Bit1.2 booleanCWTU
17Source 5output/input1 Byte5.10 counter pulses (0..255)CWTU
18Screensaver statusoutput1 Bit1.1 switchCT
18Output 15output1 Bit1.2 booleanCWTU
18Object 10 [send]output1 Bit1.1 switchCT
18Object 10 [send]output1 Bit1.8 up/downCT
18Object 10 [send]output2 Bit2.3 enable controlCT
18Object 10 [send]output1 Byte5.1 percentage (0..100%)CT
18Object 10 [send]output1 Byte5.10 counter pulses (0..255)CT
18Object 10 [send]output3 Bytes232.600 RGB value 3x(0..255)CT
18Object 10 [send]output1 Byte18.1 scene controlCT
18Object 10 [send]output1 Byte20.102 HVAC modeCT
18Object 10 [send]output2 Bytes9.1 temperature (°C)CT
18Confirm fan speed level (slave)input/output1 Byte6.10 counter pulses (-128..127)CWTU
18Source 6output/input1 Bit1.2 booleanCWTU
18Source 6output/input1 Byte5.10 counter pulses (0..255)CWTU
19Raininput1 Bit1.2 booleanCWU
19Output 16 (MSB)output1 Bit1.2 booleanCWTU
19Object 10 [receive]input1 Bit1.1 switchCWTU
19Object 10 [receive]input1 Bit1.8 up/downCWTU
19Object 10 [receive]input2 Bit2.3 enable controlCWTU
19Object 10 [receive]input1 Byte5.1 percentage (0..100%)CWTU
19Object 10 [receive]input1 Byte5.10 counter pulses (0..255)CWTU
19Object 10 [receive]input3 Bytes232.600 RGB value 3x(0..255)CWTU
19Object 10 [receive]input1 Byte18.1 scene controlCWTU
19Object 10 [receive]input1 Byte20.102 HVAC modeCWTU
19Object 10 [receive]input2 Bytes9.1 temperature (°C)CWTU
19Controller status HVAC (slave)input/output1 Byte5.10 counter pulses (0..255)CWTU
19Source 7output/input1 Bit1.2 booleanCWTU
19Source 7output/input1 Byte5.10 counter pulses (0..255)CWTU
20Temperatureinput2 Bytes9.1 temperature (°C)CWU
20Object 11 [send]output1 Bit1.1 switchCT
20Object 11 [send]output1 Bit1.8 up/downCT
20Object 11 [send]output2 Bit2.3 enable controlCT
20Object 11 [send]output1 Byte5.1 percentage (0..100%)CT
20Object 11 [send]output1 Byte5.10 counter pulses (0..255)CT
20Object 11 [send]output3 Bytes232.600 RGB value 3x(0..255)CT
20Object 11 [send]output1 Byte18.1 scene controlCT
20Object 11 [send]output1 Byte20.102 HVAC modeCT
20Object 11 [send]output2 Bytes9.1 temperature (°C)CT
20Disableinput1 Bit1.2 booleanCWU
20Source 8output/input1 Bit1.2 booleanCWTU
20Source 8output/input1 Byte5.10 counter pulses (0..255)CWTU
21Wind speedinput2 Bytes9.5 speed (m/s)CWU
21Object 11 [receive]input1 Bit1.1 switchCWTU
21Object 11 [receive]input1 Bit1.8 up/downCWTU
21Object 11 [receive]input2 Bit2.3 enable controlCWTU
21Object 11 [receive]input1 Byte5.1 percentage (0..100%)CWTU
21Object 11 [receive]input1 Byte5.10 counter pulses (0..255)CWTU
21Object 11 [receive]input3 Bytes232.600 RGB value 3x(0..255)CWTU
21Object 11 [receive]input1 Byte18.1 scene controlCWTU
21Object 11 [receive]input1 Byte20.102 HVAC modeCWTU
21Object 11 [receive]input2 Bytes9.1 temperature (°C)CWTU
21Disableinput1 Bit1.2 booleanCWU
22Brightnessinput2 Bytes9.4 lux (Lux)CWU
22Object 12 [send]output1 Bit1.1 switchCT
22Object 12 [send]output1 Bit1.8 up/downCT
22Object 12 [send]output2 Bit2.3 enable controlCT
22Object 12 [send]output1 Byte5.1 percentage (0..100%)CT
22Object 12 [send]output1 Byte5.10 counter pulses (0..255)CT
22Object 12 [send]output3 Bytes232.600 RGB value 3x(0..255)CT
22Object 12 [send]output1 Byte18.1 scene controlCT
22Object 12 [send]output1 Byte20.102 HVAC modeCT
22Object 12 [send]output2 Bytes9.1 temperature (°C)CT
23Temperature Unit selectioninput1 Bit1.1 switchCWU
23Object 12 [receive]input1 Bit1.1 switchCWTU
23Object 12 [receive]input1 Bit1.8 up/downCWTU
23Object 12 [receive]input2 Bit2.3 enable controlCWTU
23Object 12 [receive]input1 Byte5.1 percentage (0..100%)CWTU
23Object 12 [receive]input1 Byte5.10 counter pulses (0..255)CWTU
23Object 12 [receive]input3 Bytes232.600 RGB value 3x(0..255)CWTU
23Object 12 [receive]input1 Byte18.1 scene controlCWTU
23Object 12 [receive]input1 Byte20.102 HVAC modeCWTU
23Object 12 [receive]input2 Bytes9.1 temperature (°C)CWTU
24External indoor temperatureinput2 Bytes9.1 temperature (°C)CWU
24Object 13 [send]output1 Bit1.1 switchCT
24Object 13 [send]output1 Bit1.8 up/downCT
24Object 13 [send]output2 Bit2.3 enable controlCT
24Object 13 [send]output1 Byte5.1 percentage (0..100%)CT
24Object 13 [send]output1 Byte5.10 counter pulses (0..255)CT
24Object 13 [send]output3 Bytes232.600 RGB value 3x(0..255)CT
24Object 13 [send]output1 Byte18.1 scene controlCT
24Object 13 [send]output1 Byte20.102 HVAC modeCT
24Object 13 [send]output2 Bytes9.1 temperature (°C)CT
25Outdoor temperatureinput2 Bytes9.1 temperature (°C)CWU
25Object 13 [receive]input1 Bit1.1 switchCWTU
25Object 13 [receive]input1 Bit1.8 up/downCWTU
25Object 13 [receive]input2 Bit2.3 enable controlCWTU
25Object 13 [receive]input1 Byte5.1 percentage (0..100%)CWTU
25Object 13 [receive]input1 Byte5.10 counter pulses (0..255)CWTU
25Object 13 [receive]input3 Bytes232.600 RGB value 3x(0..255)CWTU
25Object 13 [receive]input1 Byte18.1 scene controlCWTU
25Object 13 [receive]input1 Byte20.102 HVAC modeCWTU
25Object 13 [receive]input2 Bytes9.1 temperature (°C)CWTU
26Internal temperatureoutput2 Bytes9.1 temperature (°C)CT
26Object 14 [send]output1 Bit1.1 switchCT
26Object 14 [send]output1 Bit1.8 up/downCT
26Object 14 [send]output2 Bit2.3 enable controlCT
26Object 14 [send]output1 Byte5.1 percentage (0..100%)CT
26Object 14 [send]output1 Byte5.10 counter pulses (0..255)CT
26Object 14 [send]output3 Bytes232.600 RGB value 3x(0..255)CT
26Object 14 [send]output1 Byte18.1 scene controlCT
26Object 14 [send]output1 Byte20.102 HVAC modeCT
26Object 14 [send]output2 Bytes9.1 temperature (°C)CT
27Sound volumeinput1 Byte5.1 percentage (0..100%)CWU
27Object 14 [receive]input1 Bit1.1 switchCWTU
27Object 14 [receive]input1 Bit1.8 up/downCWTU
27Object 14 [receive]input2 Bit2.3 enable controlCWTU
27Object 14 [receive]input1 Byte5.1 percentage (0..100%)CWTU
27Object 14 [receive]input1 Byte5.10 counter pulses (0..255)CWTU
27Object 14 [receive]input3 Bytes232.600 RGB value 3x(0..255)CWTU
27Object 14 [receive]input1 Byte18.1 scene controlCWTU
27Object 14 [receive]input1 Byte20.102 HVAC modeCWTU
27Object 14 [receive]input2 Bytes9.1 temperature (°C)CWTU
28Increase/decrease Sound volumeinput4 Bit3.7 dimming controlCWU
28Object 15 [send]output1 Bit1.1 switchCT
28Object 15 [send]output1 Bit1.8 up/downCT
28Object 15 [send]output2 Bit2.3 enable controlCT
28Object 15 [send]output1 Byte5.1 percentage (0..100%)CT
28Object 15 [send]output1 Byte5.10 counter pulses (0..255)CT
28Object 15 [send]output3 Bytes232.600 RGB value 3x(0..255)CT
28Object 15 [send]output1 Byte18.1 scene controlCT
28Object 15 [send]output1 Byte20.102 HVAC modeCT
28Object 15 [send]output2 Bytes9.1 temperature (°C)CT
29Acknowledge global [1 bit]input1 Bit1.16 acknowledgeCWU
29Object 15 [receive]input1 Bit1.1 switchCWTU
29Object 15 [receive]input1 Bit1.8 up/downCWTU
29Object 15 [receive]input2 Bit2.3 enable controlCWTU
29Object 15 [receive]input1 Byte5.1 percentage (0..100%)CWTU
29Object 15 [receive]input1 Byte5.10 counter pulses (0..255)CWTU
29Object 15 [receive]input3 Bytes232.600 RGB value 3x(0..255)CWTU
29Object 15 [receive]input1 Byte18.1 scene controlCWTU
29Object 15 [receive]input1 Byte20.102 HVAC modeCWTU
29Object 15 [receive]input2 Bytes9.1 temperature (°C)CWTU
30Scene numberinput/output1 Byte18.1 scene controlCWTU
31Activate scene 1input1 Bit1.10 start/stopCWU
32Dim scene 1input4 Bit3.7 dimming controlCWU
33Activate scene 2input1 Bit1.10 start/stopCWU
34Dim scene 2input4 Bit3.7 dimming controlCWU
35Activate scene 3input1 Bit1.10 start/stopCWU
36Dim scene 3input4 Bit3.7 dimming controlCWU
37Activate scene 4input1 Bit1.10 start/stopCWU
38Dim scene 4input4 Bit3.7 dimming controlCWU
39Activate scene 5input1 Bit1.10 start/stopCWU
40Dim scene 5input4 Bit3.7 dimming controlCWU
41Activate scene 6input1 Bit1.10 start/stopCWU
42Dim scene 6input4 Bit3.7 dimming controlCWU
43Activate scene 7input1 Bit1.10 start/stopCWU
44Dim scene 7input4 Bit3.7 dimming controlCWU
45Activate scene 8input1 Bit1.10 start/stopCWU
46Dim scene 8input4 Bit3.7 dimming controlCWU
47Activate scene 9input1 Bit1.10 start/stopCWU
48Dim scene 9input4 Bit3.7 dimming controlCWU
49Activate scene 10input1 Bit1.10 start/stopCWU
50Dim scene 10input4 Bit3.7 dimming controlCWU
1380Activationinput/output1 Bit1.10 start/stopCWTU
1381Objekt 1input/output1 Bit1.1 switchCWTU
1381Objekt 1input/output1 Byte5.1 percentage (0..100%)CWTU
1382Objekt 2input/output1 Bit1.1 switchCWTU
1382Objekt 2input/output1 Byte5.1 percentage (0..100%)CWTU
1383Objekt 3input/output1 Bit1.1 switchCWTU
1383Objekt 3input/output1 Byte5.1 percentage (0..100%)CWTU
1384Objekt 4input/output1 Bit1.1 switchCWTU
1384Objekt 4input/output1 Byte5.1 percentage (0..100%)CWTU
1385Objekt 5input/output1 Bit1.1 switchCWTU
1385Objekt 5input/output1 Byte5.1 percentage (0..100%)CWTU
1386Objekt 6input/output1 Bit1.1 switchCWTU
1386Objekt 6input/output1 Byte5.1 percentage (0..100%)CWTU
1387Objekt 7input/output1 Bit1.1 switchCWTU
1387Objekt 7input/output1 Byte5.1 percentage (0..100%)CWTU
1388Objekt 8input/output1 Bit1.1 switchCWTU
1388Objekt 8input/output1 Byte5.1 percentage (0..100%)CWTU
1389Objekt 9input/output1 Bit1.1 switchCWTU
1389Objekt 9input/output1 Byte5.1 percentage (0..100%)CWTU
1390Objekt 10input/output1 Bit1.1 switchCWTU
1390Objekt 10input/output1 Byte5.1 percentage (0..100%)CWTU
1391Objekt 11input/output1 Bit1.1 switchCWTU
1391Objekt 11input/output1 Byte5.1 percentage (0..100%)CWTU
1392Objekt 12input/output1 Bit1.1 switchCWTU
1392Objekt 12input/output1 Byte5.1 percentage (0..100%)CWTU
1393Objekt 13input/output1 Bit1.1 switchCWTU
1393Objekt 13input/output1 Byte5.1 percentage (0..100%)CWTU
1394Objekt 14input/output1 Bit1.1 switchCWTU
1394Objekt 14input/output1 Byte5.1 percentage (0..100%)CWTU
1395Objekt 15input/output1 Bit1.1 switchCWTU
1395Objekt 15input/output1 Byte5.1 percentage (0..100%)CWTU
1396Objekt 16input/output1 Bit1.1 switchCWTU
1396Objekt 16input/output1 Byte5.1 percentage (0..100%)CWTU
1397Objekt 17input/output1 Bit1.1 switchCWTU
1397Objekt 17input/output1 Byte5.1 percentage (0..100%)CWTU
1398Objekt 18input/output1 Bit1.1 switchCWTU
1398Objekt 18input/output1 Byte5.1 percentage (0..100%)CWTU
1399Objekt 19input/output1 Bit1.1 switchCWTU
1399Objekt 19input/output1 Byte5.1 percentage (0..100%)CWTU
1400Objekt 20input/output1 Bit1.1 switchCWTU
1400Objekt 20input/output1 Byte5.1 percentage (0..100%)CWTU
1401Heating control valueOutput1 Bit1.1 switchCT
1401Heating and cooling control valueOutput1 Bit1.1 switchCT
1401Heating control valueOutput1 Byte5.1 percentage (0..100%)CT
1401Heating and cooling control valueOutput1 Byte5.1 percentage (0..100%)CT
1402Additional heating stageOutput1 Bit1.1 switchCT
1402Additional stage heating and coolingOutput1 Bit1.1 switchCT
1402Additional heating stageOutput1 Byte5.1 percentage (0..100%)CT
1402Additional stage heating and coolingOutput1 Byte5.1 percentage (0..100%)CT
1403Cooling control valueOutput1 Bit1.1 switchCT
1403Cooling control valueOutput1 Byte5.1 percentage (0..100%)CT
1404Additional cooling stageOutput1 Bit1.1 switchCT
1404Additional cooling stageOutput1 Byte5.1 percentage (0..100%)CT
1405Control On/OffOutput1 Bit1.1 switchCWTU
1405Control On/Off (master)Output1 Bit1.1 switchCRWTU
1405Control On/Off (slave)Input1 Bit1.1 switchCWTU
1406Actual temperatureOutput2 BytesDPT.9CT
1406Actual temperature weightedOutput2 BytesDPT.9CT
1407External actual temperatureInput2 BytesDPT.9CWTU
1408External actual temperature 2Input2 BytesDPT.9CWTU
1409Fault actual temperatureOutput1 Bit1.1 switchCT
1409Fault, actual temperature (master)Output1 Bit1.1 switchCRT
1409Fault, actual temperature (slave)Input1 Bit1.1 switchCWTU
1410Local actual temperatureOutput2 BytesDPT.9CT
1411actual setpointOutput2 BytesDPT.9CT
1412Operating modeInput/Output1 Byte20.102 HVAC modeCWTU
1412Operating mode (master)Input/Output1 Byte20.102 HVAC modeCWTU
1412Operating mode (slave)Output1 Byte20.102 HVAC modeCT
1413Superimposed operating modeInput1 Byte20.102 HVAC modeCWTU
1413Superimposed operating mode (master/slave)Input1 Byte20.102 HVAC modeCWTU
1414Window contactInput1 Bit1.1 switchCWTU
1414Window contact (master/slave)Input1 Bit1.1 switchCWTU
1415Presence detectorInput1 Bit1.1 switchCWTU
1415Presence detector (master/slave)Input1 Bit1.1 switchCWTU
1416Status heatingOutput1 Bit1.1 switchCT
1417Status coolingOutput1 Bit1.1 switchCT
1418Basic loadInput1 Bit1.1 switchCWTU
1419Switchover heating/coolingOutput1 Bit1.1 switchCT
1419Switchover heating/coolingInput1 Bit1.1 switchCWTU
1419Switchover heating/coolingInput/Output1 Bit1.1 switchCWTU
1420Fan coil manualOutput1 Bit1.1 switchCT
1420Fan coil manual (master)Output1 Bit1.1 switchCRT
1420Fan coil manual (slave)Input1 Bit1.1 switchCWTU
1421Fan coil stepOutput1 Byte5.1 percentage (0..100%)CT
1422Fan coil step statusInput1 Byte5.1 percentage (0..100%)CWTU
1423Fan stage 1Output1 Bit1.1 switchCT
1424Fan stage 2Output1 Bit1.1 switchCT
1425Fan stage 3Output1 Bit1.1 switchCT
1426Fan stage 4Output1 Bit1.1 switchCT
1427Fan stage 5Output1 Bit1.1 switchCT
1428Basic setpointInput2 BytesDPT.9CWTU
1429Resetting manual setpointsInput1 Bit1.1 switchCWU
1430Dew point alarmInput1 Bit1.1 switchCWTU
1431Condensate water alarmInput1 Bit1.1 switchCWTU
1431Condensate water alarm (master/slave)Input1 Bit1.1 switchCWTU
1432Outside temperature for summer compensationInput2 BytesDPT.9CWTU
1433Summer compensation activeOutput1 Bit1.1 switchCT
1434Setpoint reachedOutput1 Bit1.1 switchCT
1435Units switchoverInput1 Bit1.1 switchCWTU
1435Units switchover (master)Input1 Bit1.1 switchCWTU
1435Units switchover (slave)Input1 Bit1.1 switchCWTU
1436Display backlightingInput1 Bit1.1 switchCWTU
1437On/off request (master)Input1 Bit1.1 switchCWU
1437On/off request (slave)Output1 Bit1.1 switchCT
1438Setpoint display (master)Output2 BytesDPT.9CRT
1438Setpoint display (slave)Input2 BytesDPT.9CWTU
1439Request setpoint (master)Input1 Byte5.1 percentage (0..100%)CWU
1439Request setpoint (slave)Output1 Byte5.1 percentage (0..100%)CT
1440Confirm setpoint (master)Output1 Byte5.1 percentage (0..100%)CRT
1440Confirm setpoint (slave)Input1 Byte5.1 percentage (0..100%)CWTU
1441Heating/cooling request (master)Input1 Bit1.1 switchCWU
1441Heating/cooling request (slave)Output1 Bit1.1 switchCT
1442Request fan speed level manual (master)Input1 Bit1.1 switchCWU
1442Request fan speed level manual (slave)Output1 Bit1.1 switchCT
1443Request fan speed level (master)Input1 Byte5.1 percentage (0..100%)CWU
1443Request fan speed level (slave)Output1 Byte5.1 percentage (0..100%)CT
1444Confirm fan speed level (master)Output1 Byte5.1 percentage (0..100%)CRT
1444Confirm fan speed level slave)Input1 Byte5.1 percentage (0..100%)CWTU
1445Controller status RHCCOutput2 BytesDPT.9CT
1446Controller status HVACOutput1 Byte5.1 percentage (0..100%)CT
1446Controller status HVAC (master)Output1 Byte5.1 percentage (0..100%)CRT
1446Controller status HVAC (slave)Input1 Byte5.1 percentage (0..100%)CWTU
1447CommissionedOutput1 Bit1.1 switchCT
Parameters (1415)
ParameterTypeDefault
Control frameslistinactive
Control frameslistNoIcon.png
ApplicationslistIP_LIB_panel.png
ApplicationslistSystem settings
Floor/Page FctCodelistinactive
Logic functionslistinactive
FRP iconlistNoIcon.png
Page CountunsignedInt 0…6553530
UndoRedounsignedInt 0…655350
ApplicationlistemptyText
Number of DatapointsunsignedInt 0…2558
Size of ConfigBlockunsignedInt 0…6553515
Application IdunsignedInt 0…6553549682
Application versionunsignedInt 0…6553564
Size of DeviceConfigunsignedInt 0…655356
Id of ControlunsignedInt 0…655354200
Id of ParentunsignedInt 0…655351000
PositionunsignedInt 0…640
Type of ControllistNoType
DpCfgunsignedInt 0…429496729565793
DpCfgunsignedInt 0…4294967295131587
DpCfgunsignedInt 0…429496729550528260
DpCfgunsignedInt 0…429496729567436549
DpCfgunsignedInt 0…4294967295100664839
DpCfgunsignedInt 0…4294967295460808
Use door communicationunsignedInt 0…11
Page PIN-protectedunsignedInt 0…10
PIN-code levellistLevel 1
Ringtone volume preset [%]unsignedInt 10…10070
Speech volume preset [%]unsignedInt 10…10070
Number of DatapointsunsignedInt 0…2553
Size of ConfigBlockunsignedInt 0…6553513
Application IdunsignedInt 0…6553549691
Id of ControlunsignedInt 0…655354300
DpCfgunsignedInt 0…4294967295257
DpCfgunsignedInt 0…2553
Overwrite time programs at downloadunsignedInt 0…10
Number of DatapointsunsignedInt 0…25515
Size of ConfigBlockunsignedInt 0…6553563
Application IdunsignedInt 0…6553549680
Id of ControlunsignedInt 0…655354400
DpCfgunsignedInt 0…429496729533686016
DpCfgunsignedInt 0…4294967295394759
DpCfgunsignedInt 0…4294967295458760
DpCfgunsignedInt 0…4294967295134220041
DpCfgunsignedInt 0…4294967295657920
DpCfgunsignedInt 0…4294967295185270284
DpCfgunsignedInt 0…4294967295201329933
DpCfgunsignedInt 0…4294967295921103
DpCfgunsignedInt 0…2550
Generaltext
Panel languagelistEnglish
Acoustic signal for button pressunsignedInt 0…11
Acoustic signal volume preset [%]unsignedInt 10…10050
Fractional separatorlistComma
Thousands separatorlistPoint
Time formatlist24h
Date formatlistDD-MM-YY
Send / receive time and datelistNo send and no receive
Automatic summer/winter changeoverunsignedInt 0…11
CalcParamunsignedInt 0…2550
Send time and datelistevery hour
Starting day of weeklistMonday
Lat. [dd.dd][+ = North, - = South]float -90…900
Long. [ddd.dd][+ = East, - = West]float -180…1800
Displaytext
Display brightness [%]unsignedInt 10…100100
Activate automatic return to start pageunsignedInt 0…11
Return to start page after... [s]unsignedInt 10…360060
Turn off display [min]list30
Show screensaver [min]list10
Screensaver modelistClock
Slide folder : phototext
Slide transition effectlistFade
Slide show interval [s]unsignedInt 5…12010
Order of slideslistRandom
Clock typelistAnalog
Show secondsunsignedInt 0…11
Show outdoor temperatureunsignedInt 0…11
Show rainunsignedInt 0…10
Show wind speedunsignedInt 0…10
Show brightnessunsignedInt 0…10
Temperaturetext
Temperature unitlist°C
Show room temperatureunsignedInt 0…10
Show outdoor temperatureunsignedInt 0…10
Room/outdoor temperature changeover interval [s]unsignedInt 3…105
For room temperature sensor uselistInternal sensor
Offset for temperature measurement (x 0,1K) [K]signedInt -127…1270
Send internal sensor temperaturelistDo not send
Cyclic time for automatic sending of internal sensor temperature [sec]unsignedInt 5…3600300
Securitytext
Length of PIN-Codelist4 digits
PIN-Codes can be changed by end customerunsignedInt 0…10
Enable system settings for end customerlistYes
Code for system settings [0000..9999]unsignedInt 0…99990
Code for system settings [00000..99999]unsignedInt 0…999990
Code for system settings [000000..999999]unsignedInt 0…9999990
PIN-Code Level 1unsignedInt 0…99991111
PIN-Code Level 1unsignedInt 0…9999911111
PIN-Code Level 1unsignedInt 0…999999111111
PIN-Code Level 2unsignedInt 0…99992222
PIN-Code Level 2unsignedInt 0…9999922222
PIN-Code Level 2unsignedInt 0…999999222222
PIN-Code Level 3unsignedInt 0…99993333
PIN-Code Level 3unsignedInt 0…9999933333
PIN-Code Level 3unsignedInt 0…999999333333
PIN-Code Level 4unsignedInt 0…99994444
PIN-Code Level 4unsignedInt 0…9999944444
PIN-Code Level 4unsignedInt 0…999999444444
PIN-Code Level 5unsignedInt 0…99995555
PIN-Code Level 5unsignedInt 0…9999955555
PIN-Code Level 5unsignedInt 0…999999555555
Size of ConfigBlockunsignedInt 0…6553580
Application IdunsignedInt 0…6553549693
Id of ControlunsignedInt 0…655355200
Use fault and alarm messagesunsignedInt 0…10
Enable exportunsignedInt 0…10
Filename [.CSV]textAlarm
Automatic archive at an acknowledgeunsignedInt 0…10
Automatic archive when the alarm is no longer activeunsignedInt 0…10
Sound for alarmunsignedInt 1…51
Sound for hintunsignedInt 1…52
Sound for faultunsignedInt 1…53
Sound volume preset [%]unsignedInt 10…100100
Message 1listinactive
FunctionTableForPartialDownloadunsignedInt 0…6553565535
Message 2listinactive
Message 3listinactive
Message 4listinactive
Message 5listinactive
Message 6listinactive
Message 7listinactive
Message 8listinactive
Message 9listinactive
Message 10listinactive
Message 11listinactive
Message 12listinactive
Message 13listinactive
Message 14listinactive
Message 15listinactive
Message 16listinactive
Message 17listinactive
Message 18listinactive
Message 19listinactive
Message 20listinactive
Message 21listinactive
Message 22listinactive
Message 23listinactive
Message 24listinactive
Message 25listinactive
Message 26listinactive
Message 27listinactive
Message 28listinactive
Message 29listinactive
Message 30listinactive
Message 31listinactive
Message 32listinactive
Message 33listinactive
Message 34listinactive
Message 35listinactive
Message 36listinactive
Message 37listinactive
Message 38listinactive
Message 39listinactive
Message 40listinactive
Message 41listinactive
Message 42listinactive
Message 43listinactive
Message 44listinactive
Message 45listinactive
Message 46listinactive
Message 47listinactive
Message 48listinactive
Message 49listinactive
Message 50listinactive
Message 51listinactive
Message 52listinactive
Message 53listinactive
Message 54listinactive
Message 55listinactive
Message 56listinactive
Message 57listinactive
Message 58listinactive
Message 59listinactive
Message 60listinactive
Message 61listinactive
Message 62listinactive
Message 63listinactive
Message 64listinactive
Message 65listinactive
Message 66listinactive
Message 67listinactive
Message 68listinactive
Message 69listinactive
Message 70listinactive
Message 71listinactive
Message 72listinactive
Message 73listinactive
Message 74listinactive
Message 75listinactive
Message 76listinactive
Message 77listinactive
Message 78listinactive
Message 79listinactive
Message 80listinactive
logical function 1listinactive
logical function 2listinactive
logical function 3listinactive
logical function 4listinactive
logical function 5listinactive
logical function 6listinactive
logical function 7listinactive
logical function 8listinactive
logical function 9listinactive
logical function 10listinactive
logical function 11listinactive
logical function 12listinactive
logical function 13listinactive
logical function 14listinactive
logical function 15listinactive
logical function 16listinactive
logical function 17listinactive
logical function 18listinactive
logical function 19listinactive
logical function 20listinactive
logical function 21listinactive
logical function 22listinactive
logical function 23listinactive
logical function 24listinactive
logical function 25listinactive
logical function 26listinactive
logical function 27listinactive
logical function 28listinactive
logical function 29listinactive
logical function 30listinactive
Scene actuator 1listinactive
Scene actuator 2listinactive
Scene actuator 3listinactive
Scene actuator 4listinactive
Scene actuator 5listinactive
Scene actuator 6listinactive
Scene actuator 7listinactive
Scene actuator 8listinactive
Scene actuator 9listinactive
Scene actuator 10listinactive
Number of DatapointsunsignedInt 0…25521
Size of ConfigBlockunsignedInt 0…6553576
Application IdunsignedInt 0…6553549684
Id of ControlunsignedInt 0…655355010
DpCfgunsignedInt 0…429496729533686019
DpCfgunsignedInt 0…429496729550529284
DpCfgunsignedInt 0…429496729567437829
DpCfgunsignedInt 0…4294967295101058055
DpCfgunsignedInt 0…4294967295117901320
DpCfgunsignedInt 0…4294967295134809865
DpCfgunsignedInt 0…4294967295168430091
DpCfgunsignedInt 0…4294967295185273356
DpCfgunsignedInt 0…4294967295202181901
DpCfgunsignedInt 0…4294967295235802127
DpCfgunsignedInt 0…4294967295252645392
DpCfgunsignedInt 0…4294967295269553937
DpCfgunsignedInt 0…4294967295303174163
DpCfgunsignedInt 0…4294967295320017428
DpCfgunsignedInt 0…167772151316117
Use presence simulationunsignedInt 0…10
Function PIN-protectedunsignedInt 0…10
Filename [.CSV]textPresence
Waiting time till activation [min]unsignedInt 0…602
Object type 1list1 bit
Object type 2list1 bit
Object type 3list1 bit
Object type 4list1 bit
Object type 5list1 bit
Object type 6list1 bit
Object type 7list1 bit
Object type 8list1 bit
Object type 9list1 bit
Object type 10list1 bit
Object type 11list1 bit
Object type 12list1 bit
Object type 13list1 bit
Object type 14list1 bit
Object type 15list1 bit
Object type 16list1 bit
Object type 17list1 bit
Object type 18list1 bit
Object type 19list1 bit
Object type 20list1 bit
ApplicationlistActive
Id of ControlunsignedInt 0…655350
Id of parentunsignedInt 0…655351000
Length of parameter setunsignedInt 0…65535109
Device has a user interfaceunsignedInt 0…10
GUI settings are transported by this applicationunsignedInt 0…10
Object setpoint reached visibleunsignedInt 0…10
Object display backlighting visibleunsignedInt 0…10
Request heating/cooling' object visibleunsignedInt 0…10
Local temperature object visibleunsignedInt 0…10
Local operation selectable for slave modunsignedInt 0…10
Device functionlistSingle device
Device functionlistMaster device
Colour of function illuminationlistred-orange (heating)
Basic clock rate (1 min) time basis (is hidden)unsignedInt 0…6553560
Overwrite onsite settings for downloadlistactivated
Control functionlistHeating
Control functionlistCooling
Control functionlistHeating and cooling
Additional heating stageunsignedInt 0…11
Additional cooling stageunsignedInt 0…11
Operating mode after resetlistComfort
Send cyclic 'in operation' (min)unsignedInt 5…300030
Additional functions/objectsunsignedInt 0…10
Delay time for read telegrams after reset (s)unsignedInt 1…2555
Operating functionstext
Changing set valuesunsignedInt 0…11
On/shut-off functionunsignedInt 0…11
Switchover comfort/EcounsignedInt 0…11
Switchover heating/coolingunsignedInt 0…11
Fan coil control during heating modeunsignedInt 0…11
Fan coil control during cooling modeunsignedInt 0…11
Control heatingtext
Control value type (heating)list2-point 1 bit, (Off/On)
Heating typelistConvector (e.g. heater) 1.5°C 100 min
Heating typelistFan coil 4°C 90 min
P-component heating (x 0.1°C)unsignedInt 10…10015
I-component heating (min.)unsignedInt 0…255100
P-component heating (x 0.1°C)unsignedInt 10…10040
I-component heating (min.)unsignedInt 0…255200
I-component heating (min.)unsignedInt 0…25590
p-component (x 0.1°C)unsignedInt 10…10015
I-component (min.)unsignedInt 0…255100
Extended settingsunsignedInt 0…10
Status object heatingunsignedInt 0…10
Control direction of control valuelistnormal
Hysteresis (x 0.1°C)unsignedInt 3…2555
Control value difference for sending of heating control valuelist10%
PWM cycle heating (min)unsignedInt 1…6015
PWM cycle heating (min)unsignedInt 1…6030
cyclical sending of the control value (min)unsignedInt 1…6015
Max. control value (0 to 255)unsignedInt 0…255255
Min. control value for basic load (0 to 255)unsignedInt 0…2550
Control of heating additional stagetext
Control value type (additional heating)list2-point 1 bit, (Off/On)
Additional heating typelistConvector (e.g. heater) 1.5°C 100 min
Additional heating typelistFan coil 4°C 90 min
Temperature difference to basic stage (x 0.1°C)unsignedInt 0…25520
Control coolingtext
Control value type (cooling)list2-point 1 bit, (Off/On)
Cooling typelistArea (e.g. cooling ceiling) 5°C 240 min
Cooling typelistFan coil 4°C 90 min
P-component cooling (x 0.1°C)unsignedInt 10…10050
I-component cooling (min.)unsignedInt 0…255240
I-component cooling (min.)unsignedInt 0…25590
p-component (x 0.1°C)unsignedInt 10…10020
Status object coolingunsignedInt 0…10
Control value difference for sending of cooling control valuelist10%
PWM cycle cooling (min)unsignedInt 1…6015
Control of cooling additional stagetext
Control value type (additional cooling)list2-point 1 bit, (Off/On)
Settings of basic loadtext
Min. control value for basic load > 0listalways active
Basic load active when controller is offlistyes
Combined heating and cooling modestext
Switchover heating/coolinglistautomatic
Operating mode after resetlistHeating
Output control value heating and coolinglistvia 2 objects
Output control value additional stage heating and coolinglistvia 2 objects
Setpoint settingstext
Setpoint heating comfort = setpoint cooling comfortunsignedInt 0…11
Hysteresis for switchover heating/cooling (x 0.1°C)signedInt 5…10010
Setpoint temperature for heating comfort (°C)signedInt 10…4021
Setpoint temperature for heating and cooling comfort (°C)signedInt 10…4021
Reduction for standby heating (°C)signedInt 0…152
Reduction for Eco heating (°C)signedInt 0…154
Setpoint temperature for frost protection (°C)signedInt 5…157
Setpoint temperature for cooling comfort (°C)signedInt 10…4025
Increase for cooling standby (°C)signedInt 0…152
Increase for Eco cooling (°C)signedInt 0…154
Setpoint heat protection (°C)signedInt 27…4535
Display indicateslistactual setpoint
Control extension unit indicateslistactual setpoint
Send current setpointlistOnly during change
cyclical sending of the current setpoint temperature (min)unsignedInt 5…24015
Basic setpoint islistSetpoint for heating comfort
Changing set valuestext
Step size of setpoint adjustmentlist0.5°C
Max. manual increase during heating mode (0 - 9°C)unsignedInt 0…93
Max. manual reduction during heating mode (0 - 9°C)unsignedInt 0…93
Max. manual increase during cooling mode (0 - 9°C)unsignedInt 0…93
Max. manual reduction during cooling mode (0 - 9°C)unsignedInt 0…93
Resetting of the manual adjustment for receipt of a basic set valueunsignedInt 0…11
Resetting the manual adjustment for change of operating modeunsignedInt 0…11
Resetting of the manuel adjustment for change of operation modeunsignedInt 0…11
Resetting the manual adjustment via objectlistno
Permanent storage of on-site operationunsignedInt 0…10
Temperature readingtext
Local temperature object visibleunsignedInt 0…11
Inputs of temperature readinglistInternal measurement
Inputs of temperature readinglistExternal measurement
Inputs of temperature readinglistSingle measurement
Inputs of temperature readinglist1 x internal measurement
Inputs of temperature readinglist1 x external measurement
Inputs of weighted temperature readinglistInternal and external measurement
Inputs of weighted temperature readinglist2 x external measurement
Weighting of internal measurement (0 to 100%)unsignedInt 0…100100
Weighting of internal measurement (0 to 100%)unsignedInt 0…10030
Weighting of external measurement (0 to 100%)unsignedInt 0…1000
Weighting of external measurement (0 to 100%)unsignedInt 0…10050
Weighting of external measurement (0 to 100%)unsignedInt 0…10030
Weighting of external measurement 2 (0 to 100%)unsignedInt 0…1000
Weighting of external measurement 2 (0 to 100%)unsignedInt 0…10050
cyclical sending of the actual temperature (min)unsignedInt 5…24015
Difference of value for sending the actual temperature (x 0.1°C)unsignedInt 1…1005
Adjustment value for internal temperature measurement (x 0.1°C)signedInt -127…1270
Monitoring time for temperature reading (0 = no monitoring) (min)unsignedInt 0…12050
Operating mode for faultlistHeating
Control value for fault (0 - 255)unsignedInt 0…25525
Adjustment value for external temperature measurement (x 0.1°C)signedInt -127…1270
Alarm functiontext
Condensate water alarmunsignedInt 0…10
Dew point alarmunsignedInt 0…10
Frost alarm temperature for HVAC and RHCC status (°C)signedInt 0…155
Heat alarm temperature for RHCC status (°C)signedInt 25…7040
Fan coil settingstext
Position outputunsignedInt 0…11
Number of fan stageslist3 steps
Format of the stage outputlist0..5
Position outputlistOnly for manual operation
Lowest manually adjustable fan speed levellistStage 1
Send object fan coil manual during start of manual operationunsignedInt 0…11
Evaluation stage statusunsignedInt 0…10
Fan speed level 1 up to control value (0 to 255) heatingunsignedInt 0…25550
Fan speed level 2 up to control value (0 to 255) heatingunsignedInt 0…255100
Fan speed level 3 up to control value (0 to 255) heatingunsignedInt 0…255150
Fan speed level 4 up to control value (0 to 255) heatingunsignedInt 0…255200
Fan speed level 5 up to control value (0 to 255) heatingunsignedInt 0…255250
Fan stage limit heating for ECO modeunsignedInt 0…10
max. fan stage heating for ECO modeunsignedInt 0…55
Fan speed level 1 up to control value (0 to 255) coolingunsignedInt 0…25550
Fan speed level 2 up to control value (0 to 255) coolingunsignedInt 0…255100
Fan speed level 3 up to control value (0 to 255) coolingunsignedInt 0…255150
Fan speed level 4 up to control value (0 to 255) coolingunsignedInt 0…255200
Fan speed level 5 up to control value (0 to 255) coolingunsignedInt 0…255250
Fan stage limit cooling for ECO modeunsignedInt 0…10
max. fan stage cooling for ECO modeunsignedInt 0…55
Summer compensationtext
Summer compensationunsignedInt 0…10
(lower) starting temperature for summer compensation (°C)signedInt -127…12721
Offset of the setpoint temperature for the entry in the summer compensation (x 0.1°C)signedInt -127…1270
(upper) escape temperature for summer compensation (°C)signedInt -127…12732
Offset of the setpoint for the exit from the summer compensation (x 0.1°C)signedInt -127…12760
Floor 1listinactive
Floor 2listinactive
Floor 3listinactive
Floor 4listinactive
Floor 5listinactive
Floor 6listinactive
Floor 7listinactive
Floor 8listinactive
Floor 9listinactive
Floor 10listinactive
Room 1listinactive
Room 2listinactive
Room 3listinactive
Room 4listinactive
Room 5listinactive
Room 6listinactive
Room 7listinactive
Room 8listinactive
Room 9listinactive
Room 10listinactive
Room 11listinactive
Room 12listinactive
Room 13listinactive
Room 14listinactive
Room 15listinactive
Room 16listinactive
Room 17listinactive
Room 18listinactive
Room 19listinactive
Room 20listinactive
Room 21listinactive
Room 22listinactive
Room 23listinactive
Room 24listinactive
Room 25listinactive
Room 26listinactive
Room 27listinactive
Room 28listinactive
Room 29listinactive
Applicationlistinactive
Number of DatapointsunsignedInt 0…2550
Size of ConfigBlockunsignedInt 0…6553577
Application IdunsignedInt 0…6553549666
Type of ControllistHomepage
FirstOpenunsignedInt 0…42949672950
Name of PagetextPage
Control frame 1listinactive
Control frame 2listinactive

First 500 of 1415 parameters shown. Download the .knxprod for the full list.

Application program: SmartTouch 7 DCA/3.3 3.3

Application number$6136
Version3.3
Mask versionMV-07B0 (System B)
KNX Data SecureNo
Minimum ETS version5.0
Parameters0
Group objects0
Group objects (0)
NoNameFunctionSizeDPTFlags
Parameters (0)
ParameterTypeDefault

Version history

ApplicationApp noFingerprintFirst seenSizeFile
SmartTouch_PowerTool/1 4.0 latest$6136E9F82026-11-25713 KBDownload
SmartTouch 7 DCA/3.2 3.2$61368B052026-11-25539 KBDownload

About this file

This is the official ETS product database for the ABB AG - BUSCH-JAEGER 6136/07-8xx Smart Touch 7 (6136/07-8xx), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.