Product
| Manufacturer | Thermokon Sensortechnik GmbH |
|---|---|
| Product name | JOY |
| Order number | 999999 |
| Hardware | JOY |
| Medium | Twisted Pair |
| Bus current (mA) | 10 |
| Rail mounted | No |
| Registration | Certified · 2026-04-28 |
| Catalog entry | M-0159_H-SN2025.2E03.2E04.2E001-1537_HP-FF42-30-170B_CI-999999-1 |
| Fingerprint | 170B |
| SHA-256 | 25c3fe882501eb59aac027912d540e65a5cebfd1f921efa6d211181cb87240ed |
| First seen | 2026-11-25 |
| Markets | 16 markets |
Application program: JOY 3.0
| Application number | $FF42 |
|---|---|
| Version | 3.0 |
| Mask version | MV-07B0 (System B) |
| KNX Data Secure | No |
| Minimum ETS version | 5.0 |
| Parameters | 160 |
| Group objects | 84 |
Group objects (84)
| No | Name | Function | Size | DPT | Flags |
|---|---|---|---|---|---|
| 1 | Operation State | Send in operation | 1 Bit | DPT.1 | CRT |
| 5 | Display | Enforced Software Reset | 1 Bit | DPT.1 | CW |
| 6 | Display | Device state (ON/OFF = Idle State, Bulding Protection) | 1 Bit | DPT.1 | CRT |
| 7 | Display | Input device state (ON/OFF = Idle State, Bulding Protection) | 1 Bit | DPT.1 | CW |
| 8 | Display | HMI lock | 1 Bit | DPT.1 | CW |
| 9 | Display | HMI lock fan control | 1 Bit | DPT.1 | CW |
| 10 | Alert & Messages | Alert | 1 Bit | DPT.1 | CRT |
| 11 | Alert & Messages | Input alert | 1 Bit | DPT.1 | CW |
| 12 | Alert & Messages | Frost alert | 1 Bit | DPT.1 | CRT |
| 13 | Alert & Messages | Overheat alert | 1 Bit | DPT.1 | CRT |
| 14 | Alert & Messages | CO2 value passed | 1 Bit | DPT.1 | CRT |
| 20 | Time | Time synchronization | 3 Bytes | DPT.10 | CW |
| 21 | Date | Date synchronization | 3 Bytes | DPT.11 | CW |
| 25 | Room operating mode | HVAC-Mode | 1 Byte | DPT.20 | CRT |
| 26 | Room operating mode | Input HVAC-Mode | 1 Byte | DPT.20 | CW |
| 27 | Room operating mode | Presence (Comfort/Standby) | 1 Bit | DPT.1 | CRT |
| 28 | Room operating mode | Input Presence (Comfort/Standby) | 1 Bit | DPT.1 | CW |
| 29 | Room operating mode | Output ECO mode | 1 Bit | DPT.1 | CRT |
| 30 | Room operating mode | Input ECO mode | 1 Bit | DPT.1 | CW |
| 31 | Room operating mode | Building protection | 1 Bit | DPT.1 | CRT |
| 32 | Room operating mode | Input Building protection | 1 Bit | DPT.1 | CW |
| 33 | Energy lock | Condensation | 1 Bit | DPT.1 | CRT |
| 34 | Energy lock | Input Condensation | 1 Bit | DPT.1 | CW |
| 35 | Energy lock | Output Window switch | 1 Bit | DPT.1 | CRT |
| 36 | Energy lock | Input Window switch | 1 Bit | DPT.1 | CW |
| 40 | Setpoint | Output setpoint (absolute) | 2 Bytes | DPT.9 | CRT |
| 41 | Setpoint | Output setpoint (relative) | 2 Bytes | DPT.9 | CRT |
| 42 | Setpoint | Input setpoint (absolute) | 2 Bytes | DPT.9 | CW |
| 43 | Setpoint | Input setpoint (relative) | 2 Bytes | DPT.9 | CW |
| 44 | Setpoint | Input setpoint (base) | 2 Bytes | DPT.9 | CW |
| 50 | Fan control | Fan stage [%] | 1 Byte | DPT.5 | CRT |
| 51 | Fan control | Input fan stage [%] | 1 Byte | DPT.5 | CW |
| 52 | Fan control | Fan stage integer | 1 Byte | DPT.5 | CRT |
| 53 | Fan control | Input fan stage integer | 1 Byte | DPT.5 | CW |
| 54 | Fan control | Fan stage 1 active | 1 Bit | DPT.1 | CRT |
| 55 | Fan control | Fan stage 2 active | 1 Bit | DPT.1 | CRT |
| 56 | Fan control | Fan stage 3 active | 1 Bit | DPT.1 | CRT |
| 57 | Fan control | Fan stage 1 active | 1 Bit | DPT.1 | CRT |
| 58 | Fan control | Fan stage 2 active | 1 Bit | DPT.1 | CRT |
| 59 | Fan control | Fan stage 3 active | 1 Bit | DPT.1 | CRT |
| 60 | Fan control | Fan stage 4 active | 1 Bit | DPT.1 | CRT |
| 61 | Fan control | Fan stage 5 active | 1 Bit | DPT.1 | CRT |
| 62 | Fan control | Fan stage AUTO active | 1 Bit | DPT.1 | CRT |
| 63 | Fan control | Input fan stage AUTO active | 1 Bit | DPT.1 | CW |
| 70 | Controller mode | Heating/cooling | 1 Bit | DPT.1 | CRT |
| 71 | Controller mode | Change over input | 1 Bit | DPT.1 | CW |
| 72 | Output 6 way valve | Output value PI | 1 Byte | DPT.5 | CRT |
| 75 | Controller output heating | Controller value heating | 1 Byte | DPT.5 | CRT |
| 76 | Controller output heating | Output value 2 point/PWM | 1 Bit | DPT.1 | CRT |
| 77 | Controller output heating | Output value continous | 1 Byte | DPT.5 | CRT |
| 78 | Controller output heating | Input value | 1 Bit | DPT.1 | CW |
| 79 | Controller output heating | Input value continous | 1 Byte | DPT.5 | CW |
| 80 | Controller output heating | Output active | 1 Bit | DPT.1 | CRT |
| 85 | Controller output cooling | Output value cooling | 1 Byte | DPT.5 | CRT |
| 86 | Controller output cooling | Output value 2 point/PWM | 1 Bit | DPT.1 | CRT |
| 87 | Controller output cooling | Output value continous | 1 Byte | DPT.5 | CRT |
| 88 | Controller output cooling | Input value | 1 Bit | DPT.1 | CW |
| 89 | Controller output cooling | Input value continous | 1 Byte | DPT.5 | CW |
| 90 | Controller output cooling | Output active | 1 Bit | DPT.1 | CRT |
| 95 | Sensors | Temperature | 2 Bytes | DPT.9 | CRT |
| 100 | External temperature sensor | Temperature | 2 Bytes | DPT.9 | CRT |
| 101 | Temperature | Overwrite internal temperature value | 2 Bytes | DPT.9 | CW |
| 105 | Sensors | Relative humidity | 2 Bytes | DPT.9 | CRT |
| 110 | Sensors | CO2 | 2 Bytes | DPT.9 | CRT |
| 115 | Digital input | State digital input 1 | 1 Bit | DPT.1 | CRT |
| 120 | Digital input | State digital input 2 | 1 Bit | DPT.1 | CRT |
| 125 | Light 1 | switch | 1 Bit | DPT.1 | CRT |
| 126 | Light 1 | Status | 1 Bit | DPT.1 | CW |
| 127 | Light 1 | Dimming | 4 Bit | DPT.3 | CRT |
| 128 | Light 2 | switch | 1 Bit | DPT.1 | CRT |
| 129 | Light 2 | Status | 1 Bit | DPT.1 | CW |
| 130 | Light 2 | Dimming | 4 Bit | DPT.3 | CRT |
| 131 | Light 3 | switch | 1 Bit | DPT.1 | CRT |
| 132 | Light 3 | Status | 1 Bit | DPT.1 | CW |
| 133 | Light 3 | Dimming | 4 Bit | DPT.3 | CRT |
| 140 | Blind 1 | Up / Down (long press) | 1 Bit | DPT.1 | CRT |
| 141 | Blind 1 | Lamella / Stop (short press) | 1 Bit | DPT.1 | CRT |
| 142 | Blind 1 | Up / Down (relative) | 4 Bit | DPT.3 | CRT |
| 143 | Blind 2 | Up / Down (long press) | 1 Bit | DPT.1 | CRT |
| 144 | Blind 2 | Lamella / Stop (short press) | 1 Bit | DPT.1 | CRT |
| 145 | Blind 2 | Up / Down (relative) | 4 Bit | DPT.3 | CRT |
| 146 | Blind 3 | Up / Down (long press) | 1 Bit | DPT.1 | CRT |
| 147 | Blind 3 | Lamella / Stop (short press) | 1 Bit | DPT.1 | CRT |
| 148 | Blind 3 | Up / Down (relative) | 4 Bit | DPT.3 | CRT |
Parameters (120)
| Parameter | Type | Default |
|---|---|---|
| PID_HARDWARE_TYPE_PARAMETER | list | |
| Device name | text | |
| Device type | list | Please choose |
| Temperature sensor | unsignedInt 0…1 | 1 |
| Humidity sensor | unsignedInt 0…1 | 0 |
| CO2 sensor | unsignedInt 0…1 | 0 |
| Outputs active | list | Released |
| Display language | list | German |
| Send in operation | list | Off |
| Reset via GO | list | Off |
| Device state after reset | list | On |
| Values after reset | list | Keep last values |
| Send warnings, notices, alerts | list | Off |
| Display brightness | unsignedInt 0…100 | 90 |
| Ring brightness | unsignedInt 0…100 | 20 |
| Idle state via GO | list | Off |
| Homescreen | list | Room temperature |
| Symbol 1 (footer) | list | No symbol |
| Symbol 2 (footer) | list | No symbol |
| Symbol 3 (footer) | list | No symbol |
| Symbol 4 (footer) | list | No symbol |
| Symbol 5 (footer) | list | No symbol |
| Lock parameter menu | list | Released |
| Show time | list | PM |
| Show date | list | DD/MM/YY |
| Synchronise date & time | list | Off |
| Function center key (ON/OFF) | list | No special function |
| Function upper left key | list | Off |
| Function upper right key | list | Off |
| Function lower left key | list | Off |
| Function lower right key | list | Off |
| Function center left key | list | Off |
| Function center right key | list | Off |
| Output HVAC mode | list | Off |
| HVAC mode after reset | list | Comfort |
| Override ECO mode | list | Keep ECO mode |
| Setpoint format | list | Set point offset |
| Setpoint increment | list | 0,5K |
| Base setpoint | float 0…50 | 21 |
| Setpoint range | float 0…10 | 3 |
| Offset behaviour at change of presence | list | Keep setpoint |
| Send setpoint | list | Change of Value |
| Change of Value greater | float 0.1…10 | 0.5 |
| Heartbeat setpoint | unsignedInt 1…255 | 10 |
| Controller mode | list | AUTO (4 pipe) |
| Deadband around base setpoint | float 0…15 | 2 |
| Show controller mode | list | Off |
| Valve protection | list | Off |
| Frost protection | float 0…20 | 7 |
| Overheat protection | float 20…40 | 35 |
| Minimum controller value behaviour | list | Off |
| Send controller mode | list | Cyclic |
| Heartbeat controller mode | unsignedInt 1…255 | 10 |
| 6 way valve | list | Off |
| Heating 100% (generic 6 way valve) | float 0…10 | 0 |
| Heating 0% (generic 6 way valve) | float 0…10 | 0 |
| Cooling 100% (generic 6 way valve) | float 0…10 | 0 |
| Cooling 0% (generic 6 way valve) | float 0…10 | 0 |
| Send controller value | list | Cyclic |
| Heartbeat controller value | unsignedInt 1…255 | 10 |
| Change of Value greater | float 1…100 | 5 |
| Setpoint lowering Standby (Heating) | float -10…0 | -2 |
| Setpoint lowering ECO mode (Heating) | float -10…0 | -4 |
| Controller characteristic | list | PI |
| Hysteresis (Heating) | float 0…15 | 1 |
| Cycle time | unsignedInt 5…60 | 15 |
| PI controller parameter (Xp/Tn) | list | Radiator (5K/120min) |
| Xp (user defined) | float 0…10 | 2 |
| Tn (user defined) | unsignedInt 0…1000 | 100 |
| Digital output direction Heating | list | Normally open |
| Analog output direction Heating | list | Not inverted |
| Minimum controller value heating | float 0…100 | 0 |
| Maximum controller value heating | float 0…100 | 100 |
| Setpoint increase Standby (Cooling) | float 0…10 | 2 |
| Setpoint increase ECO mode (Cooling) | float 0…10 | 4 |
| PI controller parameter (Xp/Tn) | list | Chilled ceiling (5K/240min) |
| Digital output direction Cooling | list | Normally open |
| Analog output direction Cooling | list | Not inverted |
| Minimum controller value cooling | float 0…100 | 0 |
| Maximum controller value cooling | float 0…100 | 100 |
| Fan stages | list | 3 |
| Fan stages | list | 5 |
| Fan assignment | list | Heating/Cooling |
| Threshold fan stage 1 | float 0…15 | 0 |
| Threshold fan stage 2 | float 0…15 | 1.5 |
| Threshold fan stage 2 | float 0…15 | 3 |
| Threshold maximum fan stage (100%) | float 0…15 | 3 |
| Fan stage AUTO | list | With AUTO |
| Start up time fan | float 0…30 | 0.1 |
| Follow up time fan | unsignedInt 0…600 | 0 |
| Fan minimum | float 0…100 | 0 |
| Fan stage minimal | list | Stage 0 |
| Fan maximum | float 0…100 | 100 |
| Fan start at controller value | float 0…100 | 0 |
| Fan stage limit AUTO | float 0…100 | 100 |
| Output active fan stage | list | 1 Byte integer GO |
| Send controller value | list | Change of Value |
| Change of Value greater | float 1…100 | 10 |
| Description | text | |
| Offset | float -15…15 | 0 |
| Send value | list | Change of Value |
| Heartbeat value | unsignedInt 1…255 | 10 |
| Show humidity | list | Off |
| Change of Value greater | float 1…20 | 1 |
| Threshold CO2 alert | float 400…2000 | 1200 |
| Elevation above sea level | float -200…3000 | 200 |
| Show CO2 | list | Off |
| Change of Value greater | float 10…200 | 10 |
| Type of input | list | Off |
| Input direction | list | Normally open |
| Send state of Input | list | Change of Value |
| Heartbeat state of input | unsignedInt 1…255 | 10 |
| Number lighting channels | list | 0 |
| Light 1 switch | unsignedInt 0…1 | 0 |
| Light 1 dimming | unsignedInt 0…1 | 0 |
| Light 2 switch | unsignedInt 0…1 | 0 |
| Light 2 dimming | unsignedInt 0…1 | 0 |
| Light 3 switch | unsignedInt 0…1 | 0 |
| Light 3 dimming | unsignedInt 0…1 | 0 |
| Number blind channels | list | 0 |
Version history
| Application | App no | Fingerprint | First seen | Size | File |
|---|---|---|---|---|---|
| JOY 3.0 latest | $FF42 | 170B | 2026-11-25 | 134 KB | Download |
| Novos_N7_NTouch_thanosEVO 1.1 | $FF41 | 57C3 | 2026-11-25 | 172 KB | Download |
About this file
This is the official ETS product database for the Thermokon Sensortechnik GmbH JOY (999999), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.
More from Thermokon Sensortechnik GmbH
- STC-KNX 698948
- STC-KNX-UP 725132
- USB-Interface KNX 806190