KNX-OT-Box S 8559201
Theben AG · Order number 8559201 · Gateways › OpenTherm
Control of 2 heating circuits. Can be combined with RAMSES 856 top2 OT.
Download .knxprod KNX-OT- Box S 1.0 · 116 KB
Product
| Manufacturer | Theben AG |
|---|---|
| Product name | KNX-OT-Box S |
| Order number | 8559201 |
| Product text | KNX-OT Gateway S (for OT boiler/RAMSES 856top2 OT) |
| Hardware | KNX-Opentherm-Box |
| Medium | Twisted Pair |
| Bus current (mA) | 10 |
| Rail mounted | Yes |
| Width (mm) | 70 |
| Registration | Certified · 2015-02-24 |
| Languages | de-DE, en-US, es-ES, fr-FR, it-IT, nl-NL |
| Catalog entry | M-0048_H-8559201-1_HP-855B-10-BB88_CI-8559201-1 |
| Fingerprint | BB88 |
| SHA-256 | 69fec6fb209981c22097a16995631d136057b0d899bb8c3f172235aaf7e81bb7 |
| First seen | 2026-11-25 |
| Markets | 59 markets |
Application program: KNX-OT- Box S 1.0
| Application number | $855B |
|---|---|
| Version | 1.0 |
| Mask version | MV-0705 (7.5) |
| KNX Data Secure | No |
| Parameters | 166 |
| Group objects | 91 |
Group objects (91)
| No | Name | Function | Size | DPT | Flags |
|---|---|---|---|---|---|
| 0 | H1 Flow basic set point value in comfort mode | Define flow set point value | 2 Bytes | 9.1 temperature (°C) | CRWU |
| 1 | H1 Manual offset of flow set point value | Offset flow set point value | 2 Bytes | 9.2 temperature difference (K) | CRWU |
| 2 | H1 Enable central heating | Heating on/off | 1 Bit | 1.3 enable | CRWU |
| 3 | H1 Max. actuating value zone/room 1 demand-driven | Receive actuating value | 1 Byte | 5.1 percentage (0..100%) | CRWU |
| 3 | H1 Max. act. value zone/room 1 weather + demand | Receive actuating value | 1 Byte | 5.1 percentage (0..100%) | CRWU |
| 4 | H1 Max. actuating value zone/room 2 demand-driven | Receive actuating value | 1 Byte | 5.1 percentage (0..100%) | CRWU |
| 4 | H1 Max. act. value zone/room 2 weather + demand | Receive actuating value | 1 Byte | 5.1 percentage (0..100%) | CRWU |
| 5 | H1 Max. actuating value zone/room 3 demand-driven | Receive actuating value | 1 Byte | 5.1 percentage (0..100%) | CRWU |
| 5 | H1 Max. act. value zone/room 3 weather + demand | Receive actuating value | 1 Byte | 5.1 percentage (0..100%) | CRWU |
| 6 | H1 Max. actuating value zone/room 4 demand-driven | Receive actuating value | 1 Byte | 5.1 percentage (0..100%) | CRWU |
| 6 | H1 Max. act. value zone/room 4 weather + demand | Receive actuating value | 1 Byte | 5.1 percentage (0..100%) | CRWU |
| 7 | H1 Max. actuating value zone/room 5 demand-driven | Receive actuating value | 1 Byte | 5.1 percentage (0..100%) | CRWU |
| 7 | H1 Max. act. value zone/room 5 weather + demand | Receive actuating value | 1 Byte | 5.1 percentage (0..100%) | CRWU |
| 8 | H1 Max. actuating value zone/room 6 demand-driven | Receive actuating value | 1 Byte | 5.1 percentage (0..100%) | CRWU |
| 8 | H1 Max. act. value zone/room 6 weather + demand | Receive actuating value | 1 Byte | 5.1 percentage (0..100%) | CRWU |
| 9 | H1 Max. actuating value zone/room 7 demand-driven | Receive actuating value | 1 Byte | 5.1 percentage (0..100%) | CRWU |
| 9 | H1 Max. act. value zone/room 7 weather + demand | Receive actuating value | 1 Byte | 5.1 percentage (0..100%) | CRWU |
| 10 | H1 Max. actuating value zone/room 8 demand-driven | Receive actuating value | 1 Byte | 5.1 percentage (0..100%) | CRWU |
| 10 | H1 Max. act. value zone/room 8 weather + demand | Receive actuating value | 1 Byte | 5.1 percentage (0..100%) | CRWU |
| 11 | H1 Max. actuating value zone/room 9 demand-driven | Receive actuating value | 1 Byte | 5.1 percentage (0..100%) | CRWU |
| 11 | H1 Max. act. value zone/room 9 weather + demand | Receive actuating value | 1 Byte | 5.1 percentage (0..100%) | CRWU |
| 12 | H1 Max. actuating value zone/room 10 demand-driven | Receive actuating value | 1 Byte | 5.1 percentage (0..100%) | CRWU |
| 12 | H1 Max. act. value zone/room 10 weather + demand | Receive actuating value | 1 Byte | 5.1 percentage (0..100%) | CRWU |
| 13 | Summer mode | Summer mode on/off | 1 Bit | 1.1 switch | CRWU |
| 14 | H1 HVAC operating mode heating | Receive HVAC operating mode | 1 Byte | 5.10 counter pulses (0..255) | CRWU |
| 15 | H1 Lock demand control | 1 = locked/ 0 = enabled | 1 Bit | 1.3 enable | CRWU |
| 16 | H1 Current flow temperature | Send current flow temperature | 2 Bytes | 9.1 temperature (°C) | CRTU |
| 17 | H1 Flow set point value | Send curr. flow set point val. | 2 Bytes | 9.1 temperature (°C) | CRTU |
| 18 | Flame status | Send flame status | 1 Bit | 1.1 switch | CRTU |
| 19 | General error | Report general error | 1 Bit | CRTU | |
| 20 | Error code (as per Opentherm ID 5) | Report error code | 1 Byte | 5.10 counter pulses (0..255) | CRTU |
| 21 | H1 Heating status | Report heating status | 1 Bit | 1.1 switch | CRTU |
| 22 | Service required | Report service requirement | 1 Bit | 1.1 switch | CRTU |
| 23 | Outdoor temperature | Receive outdoor temperature | 2 Bytes | 9.1 temperature (°C) | CRWU |
| 23 | Outdoor temperature | Send outdoor temperature | 2 Bytes | 9.1 temperature (°C) | CRT |
| 24 | Outdoor temperature error | Out. T. missing or incorrect | 1 Bit | 1.1 switch | CRTU |
| 25 | Enable domestic hot water (DHW) | Domestic water heating on/off | 1 Bit | 1.3 enable | CRWU |
| 26 | Current solar support | Solar support option = 1 | 1 Bit | 1.1 switch | CRWU |
| 27 | Expected solar support | Solar support option = 1 | 1 Bit | 1.1 switch | CRWU |
| 28 | HVAC operating mode domestic water | Receive HVAC operating mode | 1 Byte | 5.10 counter pulses (0..255) | CRWU |
| 29 | Forced mode domestic water | Forced mode = 1 | 1 Bit | 1.1 switch | CRWU |
| 30 | Domestic water set point value in forced mode | Define set point value | 2 Bytes | 9.1 temperature (°C) | CRWU |
| 31 | Domestic water temperature set point value | Report dom. water set point | 2 Bytes | 9.1 temperature (°C) | CRTU |
| 32 | Currrent domestic water temperature | Send current temperature | 2 Bytes | 9.1 temperature (°C) | CRTU |
| 33 | Domestic water status | Report domestic water status | 1 Bit | 1.1 switch | CRTU |
| 34 | Degree of modulation in % | Report degree of modulation | 1 Byte | 5.1 percentage (0..100%) | CT |
| 35 | Lower limit of domestic water set point value | Report boiler setting | 2 Bytes | 9.1 temperature (°C) | CT |
| 36 | Upper limit of domestic water set point value | Report boiler setting | 2 Bytes | 9.1 temperature (°C) | CT |
| 37 | H1 Lower limit of flow set point value | Report boiler setting | 2 Bytes | 9.1 temperature (°C) | CT |
| 38 | H1 Upper limit of flow set point value | Report boiler setting | 2 Bytes | 9.1 temperature (°C) | CT |
| 39 | - Nur für Test - | Für Endtest | 1 Byte | 5.10 counter pulses (0..255) | CW |
| 40 | H2 Flow basic set point value in comfort mode | Define flow set point value | 2 Bytes | 9.1 temperature (°C) | CRWU |
| 41 | H2 Manual offset of flow set point value | Offset flow set point value | 2 Bytes | 9.2 temperature difference (K) | CRWU |
| 42 | H2 Enable central heating | Heating on/off | 1 Bit | 1.3 enable | CRWU |
| 43 | H2 Max. act. value zone/room 11 weather + demand | Receive actuating value | 1 Byte | 5.1 percentage (0..100%) | CRWU |
| 43 | H2 Max. actuating value zone/room 11 demand-driven | Receive actuating value | 1 Byte | 5.1 percentage (0..100%) | CRWU |
| 44 | H2 Max. act. value zone/room 12 weather + demand | Receive actuating value | 1 Byte | 5.1 percentage (0..100%) | CRWU |
| 44 | H2 Max. actuating value zone/room 12 demand-driven | Receive actuating value | 1 Byte | 5.1 percentage (0..100%) | CRWU |
| 45 | H2 Max. act. value zone/room 13 weather + demand | Receive actuating value | 1 Byte | 5.1 percentage (0..100%) | CRWU |
| 45 | H2 Max. actuating value zone/room 13 demand-driven | Receive actuating value | 1 Byte | 5.1 percentage (0..100%) | CRWU |
| 46 | H2 Max. act. value zone/room 14 weather + demand | Receive actuating value | 1 Byte | 5.1 percentage (0..100%) | CRWU |
| 46 | H2 Max. actuating value zone/room 14 demand-driven | Receive actuating value | 1 Byte | 5.1 percentage (0..100%) | CRWU |
| 47 | H2 Max. act. value zone/room 15 weather + demand | Receive actuating value | 1 Byte | 5.1 percentage (0..100%) | CRWU |
| 47 | H2 Max. actuating value zone/room 15 demand-driven | Receive actuating value | 1 Byte | 5.1 percentage (0..100%) | CRWU |
| 48 | H2 Max. act. value zone/room 16 weather + demand | Receive actuating value | 1 Byte | 5.1 percentage (0..100%) | CRWU |
| 48 | H2 Max. actuating value zone/room 16 demand-driven | Receive actuating value | 1 Byte | 5.1 percentage (0..100%) | CRWU |
| 49 | H2 Max. act. value zone/room 17 weather + demand | Receive actuating value | 1 Byte | 5.1 percentage (0..100%) | CRWU |
| 49 | H2 Max. actuating value zone/room 17 demand-driven | Receive actuating value | 1 Byte | 5.1 percentage (0..100%) | CRWU |
| 50 | H2 Max. act. value zone/room 18 weather + demand | Receive actuating value | 1 Byte | 5.1 percentage (0..100%) | CRWU |
| 50 | H2 Max. actuating value zone/room 18 demand-driven | Receive actuating value | 1 Byte | 5.1 percentage (0..100%) | CRWU |
| 51 | H2 Max. act. value zone/room 19 weather + demand | Receive actuating value | 1 Byte | 5.1 percentage (0..100%) | CRWU |
| 51 | H2 Max. actuating value zone/room 19 demand-driven | Receive actuating value | 1 Byte | 5.1 percentage (0..100%) | CRWU |
| 52 | H2 Max. act. value zone/room 20 weather + demand | Receive actuating value | 1 Byte | 5.1 percentage (0..100%) | CRWU |
| 52 | H2 Max. actuating value zone/room 20 demand-driven | Receive actuating value | 1 Byte | 5.1 percentage (0..100%) | CRWU |
| 53 | H2 HVAC operating mode heating | Receive HVAC operating mode | 1 Byte | 5.10 counter pulses (0..255) | CRWU |
| 54 | H2 Lock demand control | 1 = locked/ 0 = enabled | 1 Bit | 1.3 enable | CRWU |
| 55 | H2 Current flow temperature | Send current flow temperature | 2 Bytes | 9.1 temperature (°C) | CRTU |
| 56 | H2 Flow set point value | Send curr. flow set point val. | 2 Bytes | 9.1 temperature (°C) | CRTU |
| 57 | H2 Heating status | Report heating status | 1 Bit | 1.1 switch | CRTU |
| 58 | Burner starts | OT- Box ID 116 | 2 Bytes | 7.1 pulses | CRTU |
| 59 | Burner operating hours | OT- Box ID 120 | 2 Bytes | 7.1 pulses | CRTU |
| 60 | H2 boiler temperature | OT- Box ID 151 | 2 Bytes | 9.1 temperature (°C) | CRTU |
| 61 | H1 Flow temperature | OT- Box ID 152 | 2 Bytes | 9.1 temperature (°C) | CRTU |
| 62 | H2 buffer temperature | OT- Box ID 153 | 2 Bytes | 9.1 temperature (°C) | CRTU |
| 63 | Water pressure | OT- Box ID 18 | 2 Bytes | 9.6 pressure (Pa) | CRTU |
| 64 | Time (DPT 10.001) | OT- Box ID 20 | 3 Bytes | 10.1 time of day | CRWU |
| 64 | Time (DPT 19.001) | OT- Box ID 20 | 8 Bytes | CRWU | |
| 65 | Room set temperature | OT- Box ID 16 | 2 Bytes | 9.1 temperature (°C) | CRWU |
| 66 | Room actual temperature | OT- Box ID 24 | 2 Bytes | 9.1 temperature (°C) | CRWU |
| 67 | Time query | Transmit | 1 Bit | 1.1 switch | CRTU |
| 68 | Burner starts/hour counter | Reset | 1 Bit | 1.1 switch | CRW |
Parameters (111)
| Parameter | Type | Default |
|---|---|---|
| General | list | 25 °C |
| Download detection | list | download |
| Activate laying readiness heating (heating circuit 1 and 2) | list | no |
| Determining the set point value heating circuit 1 | list | via heating requirement, without weather |
| Maximum flow temperature during laying readiness heating [°C] | unsignedInt 25…55 | 55 |
| Flow temperature after laying readiness heating [°C] | unsignedInt 25…55 | 25 |
| Determining the set point value heating circuit 2 | list | via heating requirement, without weather |
| Activate domestic water heating | list | yes.. |
| KNX OT interface controls | list | OT boiler |
| Format of the time object | list | 8 Byte (DPT 19.001) |
| Heating 1 | list | no |
| Control settings | list | manual |
| Flow set point value after reset [°C] | unsignedInt 20…90 | 40 |
| Base point of char.curve in °C (at 20 °C) | unsignedInt 20…90 | 40 |
| End of char. curve in °C (at -20 °C) | unsignedInt 20…90 | 80 |
| Reduction in standby mode | list | 10 K |
| Reduction in night mode | list | 15 K |
| Frost protection temperature [°C] | unsignedInt 6…30 | 10 |
| Operating mode after reset | list | comfort mode |
| CH Enable after reset | list | same as before bus failure |
| Maximum flow temperature [°C] | unsignedInt 30…90 | 70 |
| Maximum increase of flow temperature based on demand in rooms | list | 30 K |
| Maximum reduction of flow temperature if there is no demand | list | 20 K |
| Delay for adjustment of set point value | list | 15 min |
| Targeted maximum actuating value | list | 70% |
| Automatic switch to summer mode | list | no |
| Weighting factor for zone 1 | list | 1,0 |
| Weighting factor for zone 2 | list | 1,0 |
| Weighting factor for zone 3 | list | 1,0 |
| Weighting factor for zone 4 | list | 1,0 |
| Weighting factor for zone 5 | list | 1,0 |
| Weighting factor for zone 6 | list | 1,0 |
| Weighting factor for zone 7 | list | 1,0 |
| Weighting factor for zone 8 | list | 1,0 |
| Weighting factor for zone 9 | list | 1,0 |
| Weighting factor for zone 10 | list | 1,0 |
| Resend flow set point value with change at | list | 5 K |
| Send flow set point value cyclically | list | no |
| Resend current flow temperature with change at | list | 2 K |
| Send current flow temperature cyclically | list | no |
| Send CH status cyclically | list | no |
| Send CH pressure cyclically | list | no |
| Send flame status cyclically | list | no |
| Send general error cyclically | list | no |
| Send error code cyclically | list | no |
| Send service required cyclically | list | no |
| Send degree of modulation cyclically | list | no |
| Send limits of flow set point value cyclically | list | no |
| Send burner hours/burner starts cyclically | list | no |
| Time for cyclical transmission of all CH reports | list | 30 minutes |
| Heating 2 | list | no |
| Base point of char.curve in °C (at 20 °C) | unsignedInt 20…90 | 25 |
| Flow set point value after reset [°C] | unsignedInt 20…90 | 25 |
| End of char. curve in °C (at -20 °C) | unsignedInt 20…90 | 40 |
| CH2 Enable after reset | list | same as before bus failure |
| Maximum flow temperature [°C] | unsignedInt 30…90 | 40 |
| Weighting factor for zone 11 | list | 1,0 |
| Weighting factor for zone 12 | list | 1,0 |
| Weighting factor for zone 13 | list | 1,0 |
| Weighting factor for zone 14 | list | 1,0 |
| Weighting factor for zone 15 | list | 1,0 |
| Weighting factor for zone 16 | list | 1,0 |
| Weighting factor for zone 17 | list | 1,0 |
| Weighting factor for zone 18 | list | 1,0 |
| Weighting factor for zone 19 | list | 1,0 |
| Weighting factor for zone 20 | list | 1,0 |
| Send CH2 status cyclically | list | no |
| Time for cyclical transmission of all CH2 reports | list | 30 minutes |
| Determining outdoor temperature | list | via object |
| Resend outdoor temperature with change at | list | 2 K |
| Monitoring of outdoor temperature | list | no |
| Send outdoor temperature cyclically (time see CH reports) | list | no |
| Outdoor temperature monitoring time | list | every 60 min |
| Replacement value with failure or error in outdoor temperature | signedInt -20…20 | 0 |
| Outdoor temperature error or failure (time see CH reports) | list | report in event of change |
| Domestic water heating | list | no |
| Domestic water set point value in comfort mode [°C] | unsignedInt 5…90 | 60 |
| Domestic water set point value in standby mode [°C] | unsignedInt 5…90 | 45 |
| Domestic water set point value in night mode [°C] | unsignedInt 5…90 | 30 |
| Domestic water set point value frost protection [°C] | unsignedInt 5…30 | 10 |
| DHW Enable after reset | list | same as before bus failure |
| Domestic water set point value in forced mode if not via object [°C] | unsignedInt 5…90 | 85 |
| Maximum domestic water set point value [°C] | unsignedInt 30…90 | 60 |
| Energy maximisation with solar support option | list | no |
| Domestic water set point value with solar.. [°C] | unsignedInt 5…90 | 45 |
| Activate legionella protection | list | yes |
| Set point value for legionella protect. | unsignedInt 30…90 | 80 |
| Energy-saving legionella protection (performed during comfort mode) | list | every 3 days |
| Unconditional legionella protection (performed with each operating mode) | list | every 5 days |
| Send domestic water set point value in event of change | list | yes |
| Send domestic water set point value cyclically | list | no |
| Resend current domestic water temperature in event of change at | list | 2 K |
| Send current domestic water temperature cyclically | list | no |
| Send limits of domestic hot water set point value cyclically | list | no |
| Send DHW status cyclically | list | no |
| Time for cyclical transmission of all DHW reports | list | 30 minutes |
| System selection | list | System 1 |
| Boiler base temperature | list | off |
| Maximum flow temperature in main circuit [°C] | unsignedInt 36…90 | 80 |
| Maximum flow temperature in auxiliary circuit [°C] | unsignedInt 30…90 | 40 |
| Boiler temperature hysteresis [K] | unsignedInt 1…15 | 5 |
| Domestic hot water hysteresis [K] | unsignedInt 1…10 | 5 |
| Domestic hot water priority/parallel operation | list | domestic hot water has priority |
| Time delay domestic hot water pump | list | 10 min |
| Domestic hot water for frost protection | list | no |
| Time for domestic hot water circ. pump [s] (0 s = temperature-controlled) | unsignedInt 0…99 | 0 |
| Perform pump protection at | list | 12:00 |
| Pump protection duration [min] (0 = no pump protection) | unsignedInt 0…99 | 15 |
| Delta T sequence control [K] | list | 1,5 K |
| Delta T1 pump switch boiler 1 [K] | unsignedInt 5…15 | 5 |
| Delta T2 pump switch boiler 2 [K] | unsignedInt 5…15 | 5 |
Version history
| Application | App no | Fingerprint | First seen | Size | File |
|---|---|---|---|---|---|
| KNX-OT- Box S 1.0 latest | $855B | BB88 | 2026-11-25 | 116 KB | Download |
About this file
This is the official ETS product database for the Theben AG KNX-OT-Box S (8559201), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.
More from Theben AG
- AC IR Gateway KNX 4940320
- KNX-OT-Box 8559200
- DALI Gateway KNX 9070722
- Theben dummy device secure -
- TheLuxa P300 1019610
- LUXA 103 S360-12 KNX UP WH 1039052
- LUXA 103 S360-12 KNX DE WH 1039053
- LUXA 103 S360-28 KNX UP WH 1039072
- LUXA 103 S360-28 KNX DE WH 1039073
- LUXA 103 S360-12 KNX UP AN 1039152
- LUXA 103 S360-12 KNX DE AN 1039153
- LUXA 103 S360-28 KNX UP AN 1039172