RM 4 U 4940223
Theben AG · Order number 4940223 · Ausgabe › RM 4 U
4 x FIX1 switch actuator
Download .knxprod FIX1 RM 4 U 1.0 · 143 KB
Product
| Manufacturer | Theben AG |
|---|---|
| Product name | RM 4 U |
| Order number | 4940223 |
| Product text | RM 4 U (4x switch actuator) |
| Hardware | FIX1 Series RMG 4 U |
| Medium | Twisted Pair |
| Bus current (mA) | 4 |
| Rail mounted | Yes |
| Width (mm) | 72 |
| Registration | Certified · 2015-03-30 |
| Languages | de-DE, en-US, es-ES, fr-FR, it-IT, nl-NL |
| Catalog entry | M-0048_H-4940223-1_HP-4942-10-F94C_CI-4940223-1 |
| Fingerprint | F94C |
| SHA-256 | 5c6d9f310372b114720903f59a09e3da5ab83b513aa1387a3d7b66cf99827c5f |
| First seen | 2026-11-25 |
| Markets | 59 markets |
Application program: FIX1 RM 4 U 1.0
| Application number | $4942 |
|---|---|
| Version | 1.0 |
| Mask version | MV-0701 (7.1) |
| KNX Data Secure | No |
| Parameters | 538 |
| Group objects | 84 |
Group objects (84)
| No | Name | Function | Size | DPT | Flags |
|---|---|---|---|---|---|
| 0 | Channel C1 | Switching object | 1 Bit | CRW | |
| 0 | Channel C1 | Threshold value in % | 1 Byte | CRW | |
| 0 | Channel C1 | Threshold value 0..255 | 1 Byte | CRW | |
| 0 | Channel C1 | Thresh. value EIS 5 (DPT9.xxx) | 2 Bytes | CRW | |
| 0 | Channel C1 | Threshold value 0..65535 | 2 Bytes | CRW | |
| 1 | Channel C1 | Logic input in XOR gate | 1 Bit | CRW | |
| 1 | Channel C1 | Logic input in OR gate | 1 Bit | CRW | |
| 1 | Channel C1 | Logic input in AND gate | 1 Bit | CRW | |
| 2 | Channel C1 | Lock | 1 Bit | CRW | |
| 3 | Channel C1 | Call up/save scenes | 1 Byte | CRWTU | |
| 4 | Channel C1 | Lock scenes = 1 | 1 Bit | CRW | |
| 4 | Channel C1 | Enable scenes = 1 | 1 Bit | CRW | |
| 5 | Channel C1 | Feedback ON/OFF | 1 Bit | CRTU | |
| 6 | Channel C1 | Time to next service | 2 Bytes | CRWTU | |
| 6 | Channel C1 | Operating hours feedback | 2 Bytes | CRWT | |
| 7 | Channel C1 | Service required | 1 Bit | CRTU | |
| 8 | Channel C1 | Switching with priority | 2 Bit | CRW | |
| 8 | Channel C1 | Reset service | 1 Bit | CRW | |
| 8 | Channel C1 | Reset operating hours | 1 Bit | CRW | |
| 10 | Channel C2 | Switching object | 1 Bit | CRW | |
| 10 | Channel C2 | Threshold value in % | 1 Byte | CRW | |
| 10 | Channel C2 | Threshold value 0..65535 | 2 Bytes | CRW | |
| 10 | Channel C2 | Threshold value 0..255 | 1 Byte | CRW | |
| 10 | Channel C2 | Thresh. value EIS 5 (DPT9.xxx) | 2 Bytes | CRW | |
| 11 | Channel C2 | Logic input in XOR gate | 1 Bit | CRW | |
| 11 | Channel C2 | Logic input in OR gate | 1 Bit | CRW | |
| 11 | Channel C2 | Logic input in AND gate | 1 Bit | CRW | |
| 12 | Channel C2 | Lock | 1 Bit | CRW | |
| 13 | Channel C2 | Call up/save scenes | 1 Byte | CRWTU | |
| 14 | Channel C2 | Enable scenes = 1 | 1 Bit | CRW | |
| 14 | Channel C2 | Lock scenes = 1 | 1 Bit | CRW | |
| 15 | Channel C2 | Feedback ON/OFF | 1 Bit | CRTU | |
| 16 | Channel C2 | Time to next service | 2 Bytes | CRWTU | |
| 16 | Channel C2 | Operating hours feedback | 2 Bytes | CRWT | |
| 17 | Channel C2 | Service required | 1 Bit | CRTU | |
| 18 | Channel C2 | Switching with priority | 2 Bit | CRW | |
| 18 | Channel C2 | Reset service | 1 Bit | CRW | |
| 18 | Channel C2 | Reset operating hours | 1 Bit | CRW | |
| 20 | Channel C3 | Switching object | 1 Bit | CRW | |
| 20 | Channel C3 | Threshold value 0..255 | 1 Byte | CRW | |
| 20 | Channel C3 | Thresh. value EIS 5 (DPT9.xxx) | 2 Bytes | CRW | |
| 20 | Channel C3 | Threshold value 0..65535 | 2 Bytes | CRW | |
| 20 | Channel C3 | Threshold value in % | 1 Byte | CRW | |
| 21 | Channel C3 | Logic input in XOR gate | 1 Bit | CRW | |
| 21 | Channel C3 | Logic input in OR gate | 1 Bit | CRW | |
| 21 | Channel C3 | Logic input in AND gate | 1 Bit | CRW | |
| 22 | Channel C3 | Lock | 1 Bit | CRW | |
| 23 | Channel C3 | Call up/save scenes | 1 Byte | CRWTU | |
| 24 | Channel C3 | Lock scenes = 1 | 1 Bit | CRW | |
| 24 | Channel C3 | Enable scenes = 1 | 1 Bit | CRW | |
| 25 | Channel C3 | Feedback ON/OFF | 1 Bit | CRTU | |
| 26 | Channel C3 | Time to next service | 2 Bytes | CRWTU | |
| 26 | Channel C3 | Operating hours feedback | 2 Bytes | CRWT | |
| 27 | Channel C3 | Service required | 1 Bit | CRTU | |
| 28 | Channel C3 | Switching with priority | 2 Bit | CRW | |
| 28 | Channel C3 | Reset service | 1 Bit | CRW | |
| 28 | Channel C3 | Reset operating hours | 1 Bit | CRW | |
| 30 | Channel C4 | Switching object | 1 Bit | CRW | |
| 30 | Channel C4 | Threshold value 0..255 | 1 Byte | CRW | |
| 30 | Channel C4 | Thresh. value EIS 5 (DPT9.xxx) | 2 Bytes | CRW | |
| 30 | Channel C4 | Threshold value 0..65535 | 2 Bytes | CRW | |
| 30 | Channel C4 | Threshold value in % | 1 Byte | CRW | |
| 31 | Channel C4 | Logic input in XOR gate | 1 Bit | CRW | |
| 31 | Channel C4 | Logic input in OR gate | 1 Bit | CRW | |
| 31 | Channel C4 | Logic input in AND gate | 1 Bit | CRW | |
| 32 | Channel C4 | Lock | 1 Bit | CRW | |
| 33 | Channel C4 | Call up/save scenes | 1 Byte | CRWTU | |
| 34 | Channel C4 | Lock scenes = 1 | 1 Bit | CRW | |
| 34 | Channel C4 | Enable scenes = 1 | 1 Bit | CRW | |
| 35 | Channel C4 | Feedback ON/OFF | 1 Bit | CRTU | |
| 36 | Channel C4 | Time to next service | 2 Bytes | CRWTU | |
| 36 | Channel C4 | Operating hours feedback | 2 Bytes | CRWT | |
| 37 | Channel C4 | Service required | 1 Bit | CRTU | |
| 38 | Channel C4 | Switching with priority | 2 Bit | CRW | |
| 38 | Channel C4 | Reset service | 1 Bit | CRW | |
| 38 | Channel C4 | Reset operating hours | 1 Bit | CRW | |
| 78 | C1 - C4 | Manual | 1 Bit | CRWTU | |
| 79 | C1 - C4 | Central feedback | 1 Byte | CRTU | |
| 240 | Central permanent ON | RM 4 U | 1 Bit | CRWTU | |
| 241 | Central permanent OFF | RM 4 U | 1 Bit | CRWTU | |
| 242 | Central switching | RM 4 U | 1 Bit | CRWTU | |
| 243 | Central recall/save scenes | RM 4 U | 1 Byte | CRWTU | |
| 250 | BCU version | Transmit | 14 Bytes | CRTU | |
| 251 | Version C1 - C4 | Transmit | 14 Bytes | CRTU |
Parameters (82)
| Parameter | Type | Default |
|---|---|---|
| No. Of general parameters | unsignedInt 1…3 | 3 |
| Download 101 | list | yes |
| Type of basic module | list | RMG 4 U |
| Type of first extension module | list | not available/inactive |
| Type of second extension module | list | not available/inactive |
| Object link RMG8 invisible | list | |
| Type of basic module | list | RMG 4 U.. |
| Time for cycl. Transm. of feedback obj. (MIX 1 series, order no.491...) | list | 15 min. |
| Function of manual push button | list | valid until reset via object |
| Manual operation of channels | list | enabled |
| Relay switching delay | list | none |
| Transmission of central feedback | list | no |
| Time for cyclical transmission of collective feedback | list | 2 min. |
| Channel function | list | Switching ON/OFF |
| Function activated by | list | Switching object |
| Adjust lock function | list | no |
| Activate scenes | list | no |
| Participation in central objects | list | no |
| Set feedback | list | no |
| Activate hour meter | list | no |
| 1301 Switching function | list | default value - dummy |
| Activate logic link | list | no |
| Type of contact | list | NO contact |
| Status at download and bus failure | list | OFF |
| Status at download and bus failure | list | unchanged |
| Status at restoration of mains or bus power | list | OFF |
| Status at restoration of mains or bus power | list | same as before failure |
| 1301 Pulse function | list | default value - dummy |
| 1301 ON/OFF delay function | list | default value - dummy |
| 1301 Stairway light function | list | default value - dummy |
| 1301 Flashing function | list | default value - dummy |
| Hours (0..3) | unsignedInt 0…3 | 0 |
| Minutes (0..60) | unsignedInt 0…60 | 0 |
| Seconds (0..255) | unsignedInt 0…255 | 1 |
| Pulse can be retriggered (via 1 to switching object) | list | no |
| Max. cumulated pulses 1..40 | unsignedInt 1…40 | 5 |
| Pulse can be reset (with 0 on switching object) | list | no |
| Duration of first warning in s (0..60) | unsignedInt 0…60 | 10 |
| Duration of second warning in s (0..60) | unsignedInt 0…60 | 30 |
| How often should it flash | list | 3 x |
| Type of threshold value object | list | object type: percentage (dpt5.001) |
| Lower threshold value (in %) | unsignedInt 1…99 | 50 |
| Threshold | unsignedInt 1…254 | 127 |
| Lower threshold value format: (-)0,00..99999 | text | 20,0 |
| Threshold | unsignedInt 1…65534 | 1000 |
| Hysteresis (in %) | unsignedInt 1…99 | 10 |
| Hysteresis | unsignedInt 1…254 | 5 |
| Hysteresis format: 0,00..9999 | text | 1,0 |
| Hysteresis | unsignedInt 1…65534 | 5 |
| Response at exceeding threshold | list | as switching object = 1 |
| Lock telegram | list | Lock with ON telegram |
| Response when setting the lock | list | unchanged |
| Response when cancelling the lock | list | update |
| Response when cancelling the lock | list | unchanged |
| Lock telegram for scenes | list | Lock with ON telegram |
| All scene statuses of channel | list | overwrite when downloading |
| Participation in object Central scene | list | no |
| Channel reacts to | list | scene number 1 |
| Status after download | list | OFF |
| Permit teach-in | list | yes |
| Channel reacts to | list | scene number 2 |
| Channel reacts to | list | scene number 3 |
| Channel reacts to | list | scene number 4 |
| Channel reacts to | list | scene number 5 |
| Channel reacts to | list | scene number 6 |
| Channel reacts to | list | scene number 7 |
| Channel reacts to | list | scene number 8 |
| Reported status | list | not inverted |
| Transmit feedback cyclically | list | no |
| Time for cyclical transmission of feedback | list | 15 min. |
| Type of hour meter | list | operating hours counter |
| Service interval (0..2000, x 10 h) | unsignedInt 0…2000 | 100 |
| Report time to service when changed (0..100 h, 0 = no report) | unsignedInt 0…100 | 10 |
| Report operating hours at change (0..100 h, 0 = no report) | unsignedInt 0…100 | 10 |
| Transmit operating hours cyclically | list | no |
| Transmit time to service cyclically | list | no |
| Report service cyclically | list | no |
| Time for cyclical transmission (time to service) | list | 60 min |
| Time for cyclical transmission | list | 60 min |
| Activate logic link | list | AND-link |
| Lock object affects link object | list | no |
| Copy main parameters from channel C1 | list | no |
Version history
| Application | App no | Fingerprint | First seen | Size | File |
|---|---|---|---|---|---|
| FIX1 RM 4 U 1.0 latest | $4942 | F94C | 2026-11-25 | 143 KB | Download |
About this file
This is the official ETS product database for the Theben AG RM 4 U (4940223), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.
More from Theben AG
- RMG 8 490 0 251
- JMG 4 24VDC 490 0 253
- RMG 4 S 4910204
- RMG 4 C-Last 4910206
- JMG 4 S 4910250
- RMG 8 T 4930200
- RMG 4 I 4930210
- RMG 8 S 4930220
- RMG 4 U 4930223
- JMG 4 T 4930250
- JMG 4 T 24V 4930260
- RM 8 T 4940200