STEINEL HPD2 4007841033200
STEINEL professional · Order number 4007841033200 · Presence detector
Download .knxprod HPD 2 KNX V1.00 1.0 · 81 KB
Product
| Manufacturer | STEINEL professional |
|---|---|
| Product name | STEINEL HPD2 |
| Order number | 4007841033200 |
| Hardware | HPD2 |
| Medium | Twisted Pair |
| Bus current (mA) | 10 |
| Rail mounted | No |
| Registration | Registered · 2017-08-31 |
| Languages | de-DE, en-US |
| Catalog entry | M-008E_H-4007841033200-1_HP-6766-10-2E7A_CI-4007841033200-1 |
| Fingerprint | 2E7A |
| SHA-256 | 2eac4566ce5577eb28507f37aca3be175b0661d635c0e153fcd92184f32ae700 |
| First seen | 2026-11-25 |
| Markets | 69 markets |
Application program: HPD 2 KNX V1.00 1.0
| Application number | $6766 |
|---|---|
| Version | 1.0 |
| Mask version | MV-0705 (7.5) |
| KNX Data Secure | No |
| Minimum ETS version | 4.0 |
| Parameters | 184 |
| Group objects | 73 |
Group objects (73)
| No | Name | Function | Size | DPT | Flags |
|---|---|---|---|---|---|
| 0 | Output presence zone 1 {{178}} | 1 Bit | 1.1 switch | CRT | |
| 1 | Output presence zone 1 {{178}} | 1 Byte | 5.1 percentage (0..100%) | CRT | |
| 2 | Number of persons zone 1 | 1 Byte | 5.5 ratio (0..255) | CRT | |
| 3 | Light level measured zone 1 | 2 Bytes | 9.4 lux (Lux) | CRT | |
| 4 | Disable presence zone 1 | 1 Bit | 1.1 switch | CWT | |
| 5 | Presence zone 1 disabling status | 1 Bit | 1.1 switch | CRT | |
| 6 | Switch presence zone 1 | 1 Bit | 1.1 switch | CWT | |
| 7 | Dim presence zone 1 input | 4 Bit | 3.7 dimming control | CWT | |
| 8 | Time factor for presence zone 1 stay-'ON' time | 1 Byte | 5.5 ratio (0..255) | CRWT | |
| 9 | Light-level setting for zone 1 | 2 Bytes | 9.4 lux (Lux) | CRWT | |
| 10 | Output presence zone 2 {{181}} | 1 Bit | 1.1 switch | CRT | |
| 11 | Output presence zone 2 {{181}} | 1 Byte | 5.1 percentage (0..100%) | CRT | |
| 12 | Number of persons zone 2 | 1 Byte | 5.5 ratio (0..255) | CRT | |
| 13 | Light level measured zone 2 | 2 Bytes | 9.4 lux (Lux) | CRT | |
| 14 | Disable presence zone 2 | 1 Bit | 1.1 switch | CWT | |
| 15 | Presence zone 2 disabling status | 1 Bit | 1.1 switch | CRT | |
| 16 | Switch presence zone 2 | 1 Bit | 1.1 switch | CWT | |
| 17 | Dim presence zone 2 input | 4 Bit | 3.7 dimming control | CWT | |
| 18 | Time factor for presence zone 2 stay-'ON' time | 1 Byte | 5.5 ratio (0..255) | CRWT | |
| 19 | Light-level setting for zone 2 | 2 Bytes | 9.4 lux (Lux) | CRWT | |
| 20 | Output presence zone 3 {{182}} | 1 Bit | 1.1 switch | CRT | |
| 21 | Output presence zone 3 {{182}} | 1 Byte | 5.1 percentage (0..100%) | CRT | |
| 22 | Number of persons zone 3 | 1 Byte | 5.5 ratio (0..255) | CRT | |
| 23 | Light level measured zone 3 | 2 Bytes | 9.4 lux (Lux) | CRT | |
| 24 | Disable presence zone 3 | 1 Bit | 1.1 switch | CWT | |
| 25 | Presence zone 3 disabling status | 1 Bit | 1.1 switch | CRT | |
| 26 | Switch presence zone 3 | 1 Bit | 1.1 switch | CWT | |
| 27 | Dim presence zone 3 input | 4 Bit | 3.7 dimming control | CWT | |
| 28 | Time factor for presence zone 3 stay-'ON' time | 1 Byte | 5.5 ratio (0..255) | CRWT | |
| 29 | Light-level setting for zone 3 | 2 Bytes | 9.4 lux (Lux) | CRWT | |
| 30 | Output presence zone 4 {{183}} | 1 Bit | 1.1 switch | CRT | |
| 31 | Output presence zone 4 {{183}} | 1 Byte | 5.1 percentage (0..100%) | CRT | |
| 32 | Number of persons zone 4 | 1 Byte | 5.5 ratio (0..255) | CRT | |
| 33 | Light level measured zone 4 | 2 Bytes | 9.4 lux (Lux) | CRT | |
| 34 | Disable presence zone 4 | 1 Bit | 1.1 switch | CWT | |
| 35 | Presence zone 4 disabling status | 1 Bit | 1.1 switch | CRT | |
| 36 | Switch presence zone 4 | 1 Bit | 1.1 switch | CWT | |
| 37 | Dim presence zone 4 input | 4 Bit | 3.7 dimming control | CWT | |
| 38 | Time factor for presence zone 4 stay-'ON' time | 1 Byte | 5.5 ratio (0..255) | CRWT | |
| 39 | Light-level setting for zone 4 | 2 Bytes | 9.4 lux (Lux) | CRWT | |
| 40 | Output presence zone 5 {{184}} | 1 Bit | 1.1 switch | CRT | |
| 41 | Output presence zone 5 {{184}} | 1 Byte | 5.1 percentage (0..100%) | CRT | |
| 42 | Number of persons zone 5 | 1 Byte | 5.5 ratio (0..255) | CRT | |
| 43 | Light level measured zone 5 | 2 Bytes | 9.4 lux (Lux) | CRT | |
| 44 | Disable presence zone 5 | 1 Bit | 1.1 switch | CWT | |
| 45 | Presence zone 5 disabling status | 1 Bit | 1.1 switch | CRT | |
| 46 | Switch presence zone 5 | 1 Bit | 1.1 switch | CWT | |
| 47 | Dim presence zone 5 input | 4 Bit | 3.7 dimming control | CWT | |
| 48 | Time factor for presence zone 5 stay-'ON' time | 1 Byte | 5.5 ratio (0..255) | CRWT | |
| 49 | Light-level setting for zone 5 | 2 Bytes | 9.4 lux (Lux) | CRWT | |
| 50 | Output total presence | 1 Bit | 1.1 switch | CRT | |
| 51 | Output total presence | 1 Byte | 5.10 counter pulses (0..255) | CRT | |
| 52 | Number of persons total presence | 1 Byte | 5.5 ratio (0..255) | CRT | |
| 53 | Disable total presence | 1 Bit | 1.1 switch | CWT | |
| 54 | Total presence disabling status | 1 Bit | 1.1 switch | CRT | |
| 55 | Switch total presence | 1 Bit | 1.1 switch | CWT | |
| 56 | Time factor for total presence stay-'ON' time | 1 Byte | 5.5 ratio (0..255) | CRWT | |
| 57 | Time factor for total presence switch-'ON' delay | 1 Byte | 5.5 ratio (0..255) | CRWT | |
| 58 | Output threshold 1 | 1 Bit | 1.1 switch | CRT | |
| 59 | Output threshold 1 | 1 Byte | 5.10 counter pulses (0..255) | CRT | |
| 60 | Output threshold 2 | 1 Bit | 1.1 switch | CRT | |
| 61 | Output threshold 2 | 1 Byte | 5.10 counter pulses (0..255) | CRT | |
| 62 | Output threshold 3 | 1 Bit | 1.1 switch | CRT | |
| 63 | Output threshold 3 | 1 Byte | 5.10 counter pulses (0..255) | CRT | |
| 64 | Disable threshold | 1 Bit | 1.1 switch | CWT | |
| 65 | Threshold disabling status | 1 Bit | 1.1 switch | CRT | |
| 66 | Output ventilate | 1 Byte | 5.10 counter pulses (0..255) | CRT | |
| 67 | Output ventilate | 1 Byte | 5.1 percentage (0..100%) | CRT | |
| 68 | Disable ventilate | 1 Bit | 1.1 switch | CWT | |
| 69 | Ventilate disabling status | 1 Bit | 1.1 switch | CRT | |
| 70 | Sabotage protection | 1 Bit | 1.1 switch | CRT | |
| 71 | Temperature | 2 Bytes | 9.1 temperature (°C) | CRT | |
| 72 | Humidity | 2 Bytes | 9.7 humidity (%) | CRT |
Parameters (67)
| Parameter | Type | Default |
|---|---|---|
| Number of zones | unsignedInt 1…5 | 1 |
| Total presence | list | inactive |
| Threshold control | list | inactive |
| Ventilate | list | inactive |
| Sabotage | list | inactive |
| LED | list | inactive |
| Temperature | list | inactive |
| Humidity | list | inactive |
| Telegram type | list | ON/OFF |
| Value if presence | unsignedInt 0…100 | 100 |
| Value if no presence | unsignedInt 0…100 | 0 |
| Daytime | list | No |
| Light-level | unsignedInt 2…2000 | 400 |
| Constant-lighting control | list | No |
| Start dim level | unsignedInt 1…100 | 80 |
| Max variation from the setting | list | 15 Lux |
| Max. dimming step | list | 2 % |
| Send new dim level after | list | 2s |
| Lighting with sufficient daylight | list | switching OFF |
| Min. dimming level | list | 0,5 % |
| Light-level control for dim light input | list | disable and dim |
| Stay-'ON' time | unsignedInt 0…255 | 8 |
| Send number of persons | unsignedInt 0…255 | 2 |
| Send Brightness value | list | no |
| Brightness value cyclically | unsignedInt 1…255 | 5 |
| Brightness level to change | unsignedInt 1…255 | 50 |
| Disable output | list | No |
| Behaviour on disabling | list | no action |
| Basic illumination | list | inactive |
| Basic illumination dimming level | unsignedInt 1…100 | 10 |
| Basic illumination ON | list | for a limited time |
| Basic illumination 'ON' period | unsignedInt 1…255 | 15 |
| Basic light-level threshold | unsignedInt 2…2000 | 50 |
| Zone 1 | list | active |
| Zone 2 | list | active |
| Zone 3 | list | active |
| Zone 4 | list | active |
| Zone 5 | list | active |
| Value if presence | unsignedInt 0…255 | 255 |
| Value if no presence | unsignedInt 0…255 | 0 |
| Switch-'ON' delay | unsignedInt 0…255 | 0 |
| Threshold 1 | unsignedInt 1…255 | 2 |
| Threshold 2 | unsignedInt 1…255 | 4 |
| Threshold 3 | unsignedInt 1…255 | 6 |
| Below threshold 1 | unsignedInt 0…255 | 0 |
| Above threshold 1 | unsignedInt 0…255 | 85 |
| Below threshold 2 | unsignedInt 0…255 | 85 |
| Above Threshold 2 | unsignedInt 0…255 | 170 |
| Below threshold 3 | unsignedInt 0…255 | 170 |
| Above Threshold 3 | unsignedInt 0…255 | 255 |
| Telegram type | list | Value |
| Between threshold 1 and 2 | unsignedInt 0…255 | 85 |
| Between threshold 2 and 3 | unsignedInt 0…255 | 170 |
| Above threshold 3 | unsignedInt 0…255 | 255 |
| Below threshold 1 | unsignedInt 0…100 | 0 |
| Between threshold 1 and 2 | unsignedInt 0…100 | 35 |
| Between threshold 2 and 3 | unsignedInt 0…100 | 70 |
| Above threshold 3 | unsignedInt 0…100 | 100 |
| Telegram | list | ON |
| Send sabotage cyclically | list | 1 min |
| Temperature level to change (x0.1°C) | unsignedInt 1…255 | 1 |
| Temperature value cyclically | unsignedInt 0…255 | 0 |
| Humidity level to change (x0.1%) | unsignedInt 1…255 | 1 |
| Humidity value cyclically | unsignedInt 0…255 | 1 |
| InitFlag | unsignedInt 0…65535 | 45054 |
| InitFlagSave | unsignedInt 0…65535 | 65535 |
| User description | text |
Version history
| Application | App no | Fingerprint | First seen | Size | File |
|---|---|---|---|---|---|
| HPD 2 KNX V1.00 1.0 latest | $6766 | 2E7A | 2026-11-25 | 81 KB | Download |
About this file
This is the official ETS product database for the STEINEL professional STEINEL HPD2 (4007841033200), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.
More from STEINEL professional
- STEINEL IR Quattro KNX 4007841002701
- STEINEL IR Quattro HD KNX 4007841002763
- STEINEL HF 360 KNX 4007841002824
- STEINEL DUAL HF KNX 4007841002992
- STEINEL IR Quattro KNX 4007841008772
- STEINEL IR Quattro HD KNX 4007841008789
- STEINEL HF 360 KNX 4007841008796
- STEINEL DUAL HF KNX 4007841008802
- STEINEL US 360 KNX 4007841029463
- STEINEL DUAL US KNX 4007841029470
- STEINEL SINGLE US KNX 4007841029487
- STEINEL Dualtech KNX 4007841029494