Weather Station KNX 1870932

Somfy · Order number 1870932 · Phys. Sensors › Weather Station

Weather Station

Download .knxprod Weather Station 3.0 · 333 KB

Product

ManufacturerSomfy
Product nameWeather Station KNX
Order number1870932
HardwareWetterstation Komfort Plus
MediumTwisted Pair
Bus current (mA)5
Rail mountedNo
RegistrationCertified · 2021-02-18
Languagesde-DE, en-US, fr-FR
Catalog entryM-004E_H-4E.20.2F.2F.201870932-1-O00F4_HP-B00D-30-0ED8-O000A_CI-1870932-1
Fingerprint0ED8
SHA-256965dfff3fd63face38510ccce1cfce8e2fea758dcb70aab1419f5228d4480443
First seen2026-11-25
Markets30 markets

Application program: Weather Station 3.0

Application number$B00D
Version3.0
Mask versionMV-07B0 (System B)
KNX Data SecureNo
Minimum ETS version5.0
Parameters1264
Group objects353
Group objects (353)
NoNameFunctionSizeDPTFlags
1Measured value wind speed [m/s]Wind2 Bytes9.5 speed (m/s)CRT
2Measured value wind direction [0...360°]Wind1 Byte5.3 angle (degrees)CRT
3Measured value, wind orientationWind14 Bytes16.0 Character String (ASCII)CRT
4Measured value, wind area signalWind1 Bit1.1 switchCRT
5Measured value for brightnessBrightness sensor 12 Bytes9.4 lux (Lux)CRT
6Measured value for brightnessBrightness sensor 22 Bytes9.4 lux (Lux)CRT
7Measured value for brightnessBrightness sensor 32 Bytes9.4 lux (Lux)CRT
8Measured value for brightnessBrightness sensor 42 Bytes9.4 lux (Lux)CRT
9Measured value for twilightTwilight2 Bytes9.4 lux (Lux)CRT
10Measured value, global radiationGlobal radiation2 Bytes9.22 power density (W/m²)CRT
11Measured value precipitationPrecipitation1 Bit1.1 switchCRT
12Measured value for temperatureTemperature2 Bytes9.1 temperature (°C)CRT
13Measured value, relative humidityRelative humidity2 Bytes9.7 humidity (%)CRT
14Measured value, air pressureAir pressure2 Bytes9.6 pressure (Pa)CRT
15 Measured valueGPS.Time3 Bytes10.1 time of dayCT
16 Measured valueGPS.Date3 Bytes11.1 dateCT
17 Measured valueGPS.Geographic longitude4 Bytes14.7 angle (degree)CR
18 Measured valueGPS.Geographic latitude4 Bytes14.7 angle (degree)CR
19 Measured valueGPS.Azimuth1 Byte5.3 angle (degrees)CRT
19 Measured valueAzimuth1 Byte5.3 angle (degrees)CRT
20 Measured valueGPS.Elevation1 Byte5.3 angle (degrees)CRT
20 Measured valueElevation1 Byte5.3 angle (degrees)CRT
21 Measured valueGPS.Location height4 Bytes14.39 length (m)CR
22 Measured valueGPS.Time change1 Bit1.1 switchCW
22 Measured valueTime change1 Bit1.1 switchCW
23 Measured valueGPS.Send request date/time1 Bit1.1 switchCW
24Measured value for brightnessMax. brightness sensors 1 to 42 Bytes9.4 lux (Lux)CRT
25Measured value for brightness and twilightMax. brightness and twilight2 Bytes9.4 lux (Lux)CRT
26Measured value absolute humidityAbsolute humidity2 Bytes7.1 pulsesCRT
26Measured value absolute humidityAbsolute humidity2 BytesDPT.9CRT
27Measured value felt temperatureFelt temperature2 Bytes9.1 temperature (°C)CRT
28Measured value, oppressivenessOppressiveness1 Bit1.1 switchCRT
29Measured value, comfortComfort1 Bit1.1 switchCRT
30Limiting value 1Wind speed1 Bit1.1 switchCT
31Limiting value 1Wind direction1 Bit1.1 switchCT
32Limiting value 1Brightness sensor 11 Bit1.1 switchCT
33Limiting value 1Brightness sensor 21 Bit1.1 switchCT
34Limiting value 1Brightness sensor 31 Bit1.1 switchCT
35Limiting value 1Brightness sensor 41 Bit1.1 switchCT
36Limiting value 1Twilight1 Bit1.1 switchCT
37Limiting value 1Global radiation1 Bit1.1 switchCT
38Limiting value 1Precipitation1 Bit1.1 switchCT
39Limiting value 1Temperature1 Bit1.1 switchCT
40Limiting value 1Relative humidity1 Bit1.1 switchCT
41Limiting value 1Air pressure1 Bit1.1 switchCT
42Limiting value 1Max. brightness sensors 1 to 41 Bit1.1 switchCT
43Limiting value 1Max. brightness and twilight1 Bit1.1 switchCT
44Limiting value 1Absolute humidity1 Bit1.1 switchCT
45Limiting value 1Felt temperature1 Bit1.1 switchCT
46Limiting value 2Wind speed1 Bit1.1 switchCT
47Limiting value 2Wind direction1 Bit1.1 switchCT
48Limiting value 2Brightness sensor 11 Bit1.1 switchCT
49Limiting value 2Brightness sensor 21 Bit1.1 switchCT
50Limiting value 2Brightness sensor 31 Bit1.1 switchCT
51Limiting value 2Brightness sensor 41 Bit1.1 switchCT
52Limiting value 2Twilight1 Bit1.1 switchCT
53Limiting value 2Global radiation1 Bit1.1 switchCT
54Limiting value 2Precipitation1 Bit1.1 switchCT
55Limiting value 2Temperature1 Bit1.1 switchCT
56Limiting value 2Relative humidity1 Bit1.1 switchCT
57Limiting value 2Air pressure1 Bit1.1 switchCT
58Limiting value 2Max. brightness sensors 1 to 41 Bit1.1 switchCT
59Limiting value 2Max. brightness and twilight1 Bit1.1 switchCT
60Limiting value 2Absolute humidity1 Bit1.1 switchCT
61Limiting value 2Felt temperature1 Bit1.1 switchCT
62External limiting value 1 (teach-in)Wind speed1 Bit1.1 switchCW
62External limiting value 1Wind speed1 Byte5.1 percentage (0..100%)CW
62External limiting value 1Wind speed2 Bytes9.5 speed (m/s)CW
63External limiting value 1 (teach-in)Wind direction1 Bit1.1 switchCW
63External limiting value 1Wind direction1 Byte5.1 percentage (0..100%)CW
63External limiting value 1Wind direction1 Byte5.3 angle (degrees)CW
63External limiting value 1Wind direction2 BytesDPT.9CW
64External limiting value 1 (teach-in)Brightness sensor 11 Bit1.1 switchCW
64External limiting value 1Brightness sensor 11 Byte5.1 percentage (0..100%)CW
64External limiting value 1Brightness sensor 12 Bytes9.4 lux (Lux)CW
65External limiting value 1 (teach-in)Brightness sensor 21 Bit1.1 switchCW
65External limiting value 1Brightness sensor 21 Byte5.1 percentage (0..100%)CW
65External limiting value 1Brightness sensor 22 Bytes9.4 lux (Lux)CW
66External limiting value 1 (teach-in)Brightness sensor 31 Bit1.1 switchCW
66External limiting value 1Brightness sensor 31 Byte5.1 percentage (0..100%)CW
66External limiting value 1Brightness sensor 32 Bytes9.4 lux (Lux)CW
67External limiting value 1 (teach-in)Brightness sensor 41 Bit1.1 switchCW
67External limiting value 1Brightness sensor 41 Byte5.1 percentage (0..100%)CW
67External limiting value 1Brightness sensor 42 Bytes9.4 lux (Lux)CW
68External limiting value 1 (teach-in)Twilight1 Bit1.1 switchCW
68External limiting value 1Twilight1 Byte5.1 percentage (0..100%)CW
68External limiting value 1Twilight2 Bytes9.4 lux (Lux)CW
69External limiting value 1 (teach-in)Global radiation1 Bit1.1 switchCW
69External limiting value 1Global radiation1 Byte5.1 percentage (0..100%)CW
69External limiting value 1Global radiation2 Bytes9.22 power density (W/m²)CW
70External limiting value 1 (teach-in)Precipitation1 Bit1.1 switchCW
70External limiting value 1Precipitation2 Bytes8.1 pulses differenceCW
70External limiting value 1Precipitation1 Byte5.1 percentage (0..100%)CW
71External limiting value 1 (teach-in)Temperature1 Bit1.1 switchCW
71External limiting value 1Temperature1 Byte5.1 percentage (0..100%)CW
71External limiting value 1Temperature2 Bytes9.1 temperature (°C)CW
72External limiting value 1 (teach-in)Relative humidity1 Bit1.1 switchCW
72External limiting value 1Relative humidity1 Byte5.1 percentage (0..100%)CW
72External limiting value 1Relative humidity2 Bytes9.7 humidity (%)CW
73External limiting value 1 (teach-in)Air pressure1 Bit1.1 switchCW
73External limiting value 1Air pressure1 Byte5.1 percentage (0..100%)CW
73External limiting value 1Air pressure2 Bytes9.6 pressure (Pa)CW
74External limiting value 1 (teach-in)Max. brightness sensors 1 to 41 Bit1.1 switchCW
74External limiting value 1Max. brightness sensors 1 to 41 Byte5.1 percentage (0..100%)CW
74External limiting value 1Max. brightness sensors 1 to 42 Bytes9.4 lux (Lux)CW
75External limiting value 1 (teach-in)Max. brightness and twilight1 Bit1.1 switchCW
75External limiting value 1Max. brightness and twilight1 Byte5.1 percentage (0..100%)CW
75External limiting value 1Max. brightness and twilight2 Bytes9.4 lux (Lux)CW
76External limiting value 1 (teach-in)Absolute humidity1 Bit1.1 switchCW
76External limiting value 1Absolute humidity1 Byte5.1 percentage (0..100%)CW
76External limiting value 1Absolute humidity2 BytesDPT.9CW
77External limiting value 1 (teach-in)Felt temperature1 Bit1.1 switchCW
77External limiting value 1Felt temperature1 Byte5.1 percentage (0..100%)CW
77External limiting value 1Felt temperature2 Bytes9.1 temperature (°C)CW
78External limiting value 2Wind speed2 Bytes9.5 speed (m/s)CW
78External limiting value 2Wind speed1 Byte5.1 percentage (0..100%)CW
78External limiting value 2 (teach-in)Wind speed1 Bit1.1 switchCW
79External limiting value 2 (teach-in)Wind direction1 Bit1.1 switchCW
79External limiting value 2Wind direction1 Byte5.1 percentage (0..100%)CW
79External limiting value 2Wind direction1 Byte5.3 angle (degrees)CW
79External limiting value 2Wind direction2 BytesDPT.9CW
80External limiting value 2Brightness sensor 12 Bytes9.4 lux (Lux)CW
80External limiting value 2 (teach-in)Brightness sensor 11 Bit1.1 switchCW
80External limiting value 2Brightness sensor 11 Byte5.1 percentage (0..100%)CW
81External limiting value 2Brightness sensor 22 Bytes9.4 lux (Lux)CW
81External limiting value 2 (teach-in)Brightness sensor 21 Bit1.1 switchCW
81External limiting value 2Brightness sensor 21 Byte5.1 percentage (0..100%)CW
82External limiting value 2Brightness sensor 32 Bytes9.4 lux (Lux)CW
82External limiting value 2 (teach-in)Brightness sensor 31 Bit1.1 switchCW
82External limiting value 2Brightness sensor 31 Byte5.1 percentage (0..100%)CW
83External limiting value 2Brightness sensor 42 Bytes9.4 lux (Lux)CW
83External limiting value 2 (teach-in)Brightness sensor 41 Bit1.1 switchCW
83External limiting value 2Brightness sensor 41 Byte5.1 percentage (0..100%)CW
84External limiting value 2Twilight2 Bytes9.4 lux (Lux)CW
84External limiting value 2 (teach-in)Twilight1 Bit1.1 switchCW
84External limiting value 2Twilight1 Byte5.1 percentage (0..100%)CW
85External limiting value 2Global radiation2 Bytes9.22 power density (W/m²)CW
85External limiting value 2 (teach-in)Global radiation1 Bit1.1 switchCW
85External limiting value 2Global radiation1 Byte5.1 percentage (0..100%)CW
86External limiting value 2Precipitation2 Bytes8.1 pulses differenceCW
86External limiting value 2 (teach-in)Precipitation1 Bit1.1 switchCW
86External limiting value 2Precipitation1 Byte5.1 percentage (0..100%)CW
87External limiting value 2Temperature2 Bytes9.1 temperature (°C)CW
87External limiting value 2 (teach-in)Temperature1 Bit1.1 switchCW
87External limiting value 2Temperature1 Byte5.1 percentage (0..100%)CW
88External limiting value 2Relative humidity2 Bytes9.7 humidity (%)CW
88External limiting value 2 (teach-in)Relative humidity1 Bit1.1 switchCW
88External limiting value 2Relative humidity1 Byte5.1 percentage (0..100%)CW
89External limiting value 2Air pressure2 Bytes9.6 pressure (Pa)CW
89External limiting value 2 (teach-in)Air pressure1 Bit1.1 switchCW
89External limiting value 2Air pressure1 Byte5.1 percentage (0..100%)CW
90External limiting value 2Max. brightness sensors 1 to 42 Bytes9.4 lux (Lux)CW
90External limiting value 2 (teach-in)Max. brightness sensors 1 to 41 Bit1.1 switchCW
90External limiting value 2Max. brightness sensors 1 to 41 Byte5.1 percentage (0..100%)CW
91External limiting value 2Max. brightness and twilight2 Bytes9.4 lux (Lux)CW
91External limiting value 2 (teach-in)Max. brightness and twilight1 Bit1.1 switchCW
91External limiting value 2Max. brightness and twilight1 Byte5.1 percentage (0..100%)CW
92External limiting value 2 (teach-in)Absolute humidity1 Bit1.1 switchCW
92External limiting value 2Absolute humidity1 Byte5.1 percentage (0..100%)CW
92External limiting value 2Absolute humidity2 BytesDPT.9CW
93External limiting value 2Felt temperature2 Bytes9.1 temperature (°C)CW
93External limiting value 2 (teach-in)Felt temperature1 Bit1.1 switchCW
93External limiting value 2Felt temperature1 Byte5.1 percentage (0..100%)CW
94Input value 2 byteDisabling module 12 BytesDPT.9CW
94Input value 1 byteDisabling module 11 Byte5.1 percentage (0..100%)CW
94Input switchingDisabling module 11 Bit1.1 switchCW
95Output value 2 byteDisabling module 12 BytesDPT.9CT
95Output value 1 byteDisabling module 11 Byte5.1 percentage (0..100%)CT
95Output switchingDisabling module 11 Bit1.1 switchCT
96Disabling objectDisabling module 11 Bit1.1 switchCW
97Input value 2 byteDisabling module 22 BytesDPT.9CW
97Input value 1 byteDisabling module 21 Byte5.1 percentage (0..100%)CW
97Input switchingDisabling module 21 Bit1.1 switchCW
98Output value 2 byteDisabling module 22 BytesDPT.9CT
98Output value 1 byteDisabling module 21 Byte5.1 percentage (0..100%)CT
98Output switchingDisabling module 21 Bit1.1 switchCT
99Disabling objectDisabling module 21 Bit1.1 switchCW
100Input value 2 byteDisabling module 32 BytesDPT.9CW
100Input value 1 byteDisabling module 31 Byte5.1 percentage (0..100%)CW
100Input switchingDisabling module 31 Bit1.1 switchCW
101Output value 2 byteDisabling module 32 BytesDPT.9CT
101Output value 1 byteDisabling module 31 Byte5.1 percentage (0..100%)CT
101Output switchingDisabling module 31 Bit1.1 switchCT
102Disabling objectDisabling module 31 Bit1.1 switchCW
103Input value 2 byteDisabling module 42 BytesDPT.9CW
103Input value 1 byteDisabling module 41 Byte5.1 percentage (0..100%)CW
103Input switchingDisabling module 41 Bit1.1 switchCW
104Output value 2 byteDisabling module 42 BytesDPT.9CT
104Output value 1 byteDisabling module 41 Byte5.1 percentage (0..100%)CT
104Output switchingDisabling module 41 Bit1.1 switchCT
105Disabling objectDisabling module 41 Bit1.1 switchCW
106 Input 1Logic gate 11 Bit1.1 switchCW
107 Input 2Logic gate 11 Bit1.1 switchCW
108 Input 3Logic gate 11 Bit1.1 switchCW
109 Input 4Logic gate 11 Bit1.1 switchCW
110OutputLogic gate 11 Bit1.1 switchCT
111 Input 1Logic gate 21 Bit1.1 switchCW
112 Input 2Logic gate 21 Bit1.1 switchCW
113 Input 3Logic gate 21 Bit1.1 switchCW
114 Input 4Logic gate 21 Bit1.1 switchCW
115OutputLogic gate 21 Bit1.1 switchCT
116 Input 1Logic gate 31 Bit1.1 switchCW
117 Input 2Logic gate 31 Bit1.1 switchCW
118 Input 3Logic gate 31 Bit1.1 switchCW
119 Input 4Logic gate 31 Bit1.1 switchCW
120OutputLogic gate 31 Bit1.1 switchCT
121 Input 1Logic gate 41 Bit1.1 switchCW
122 Input 2Logic gate 41 Bit1.1 switchCW
123 Input 3Logic gate 41 Bit1.1 switchCW
124 Input 4Logic gate 41 Bit1.1 switchCW
125OutputLogic gate 41 Bit1.1 switchCT
126 Input 1Logic gate 51 Bit1.1 switchCW
127 Input 2Logic gate 51 Bit1.1 switchCW
128 Input 3Logic gate 51 Bit1.1 switchCW
129 Input 4Logic gate 51 Bit1.1 switchCW
130OutputLogic gate 51 Bit1.1 switchCT
131 Input 1Logic gate 61 Bit1.1 switchCW
132 Input 2Logic gate 61 Bit1.1 switchCW
133 Input 3Logic gate 61 Bit1.1 switchCW
134 Input 4Logic gate 61 Bit1.1 switchCW
135OutputLogic gate 61 Bit1.1 switchCT
136 Input 1Logic gate 71 Bit1.1 switchCW
137 Input 2Logic gate 71 Bit1.1 switchCW
138 Input 3Logic gate 71 Bit1.1 switchCW
139 Input 4Logic gate 71 Bit1.1 switchCW
140OutputLogic gate 71 Bit1.1 switchCT
141 Input 1Logic gate 81 Bit1.1 switchCW
142 Input 2Logic gate 81 Bit1.1 switchCW
143 Input 3Logic gate 81 Bit1.1 switchCW
144 Input 4Logic gate 81 Bit1.1 switchCW
145OutputLogic gate 81 Bit1.1 switchCT
146 Input 1Logic gate 91 Bit1.1 switchCW
147 Input 2Logic gate 91 Bit1.1 switchCW
148 Input 3Logic gate 91 Bit1.1 switchCW
149 Input 4Logic gate 91 Bit1.1 switchCW
150OutputLogic gate 91 Bit1.1 switchCT
151 Input 1Logic gate 101 Bit1.1 switchCW
152 Input 2Logic gate 101 Bit1.1 switchCW
153 Input 3Logic gate 101 Bit1.1 switchCW
154 Input 4Logic gate 101 Bit1.1 switchCW
155OutputLogic gate 101 Bit1.1 switchCT
156 Input 1Logic gate 111 Bit1.1 switchCW
157 Input 2Logic gate 111 Bit1.1 switchCW
158 Input 3Logic gate 111 Bit1.1 switchCW
159 Input 4Logic gate 111 Bit1.1 switchCW
160OutputLogic gate 111 Bit1.1 switchCT
161 Input 1Logic gate 121 Bit1.1 switchCW
162 Input 2Logic gate 121 Bit1.1 switchCW
163 Input 3Logic gate 121 Bit1.1 switchCW
164 Input 4Logic gate 121 Bit1.1 switchCW
165OutputLogic gate 121 Bit1.1 switchCT
166 Input 1Logic gate 131 Bit1.1 switchCW
167 Input 2Logic gate 131 Bit1.1 switchCW
168 Input 3Logic gate 131 Bit1.1 switchCW
169 Input 4Logic gate 131 Bit1.1 switchCW
170OutputLogic gate 131 Bit1.1 switchCT
171 Input 1Logic gate 141 Bit1.1 switchCW
172 Input 2Logic gate 141 Bit1.1 switchCW
173 Input 3Logic gate 141 Bit1.1 switchCW
174 Input 4Logic gate 141 Bit1.1 switchCW
175OutputLogic gate 141 Bit1.1 switchCT
176 Input 1Logic gate 151 Bit1.1 switchCW
177 Input 2Logic gate 151 Bit1.1 switchCW
178 Input 3Logic gate 151 Bit1.1 switchCW
179 Input 4Logic gate 151 Bit1.1 switchCW
180OutputLogic gate 151 Bit1.1 switchCT
181 Input 1Logic gate 161 Bit1.1 switchCW
182 Input 2Logic gate 161 Bit1.1 switchCW
183 Input 3Logic gate 161 Bit1.1 switchCW
184 Input 4Logic gate 161 Bit1.1 switchCW
185OutputLogic gate 161 Bit1.1 switchCT
202External basic brightnessShading control1 Byte5.10 counter pulses (0..255)CW
203Shading facade 1Shading control1 Byte5.1 percentage (0..100%)CT
203Shading facade 1Shading control1 Bit1.1 switchCT
204Opening angle facade 1Individual control1 Byte5.3 angle (degrees)CW
205Blind/shutter height, facade 1 positionIndividual control1 Byte5.1 percentage (0..100%)CT
205Blind/shutter height facade 1 threshold 1Individual control1 Bit1.1 switchCT
206Blind/shutter height facade 1 threshold 2Individual control1 Bit1.1 switchCT
207Blind/shutter height facade 1 threshold 3Individual control1 Bit1.1 switchCT
208Slat position facade 1Individual control1 Byte5.1 percentage (0..100%)CT
209Disable facade 1Shading control1 Bit1.1 switchCW
210Shading facade 2Shading control1 Byte5.1 percentage (0..100%)CT
210Shading facade 2Shading control1 Bit1.1 switchCT
211Opening angle facade 2Individual control1 Byte5.3 angle (degrees)CW
212Blind/shutter height, facade 2 positionIndividual control1 Byte5.1 percentage (0..100%)CT
212Blind/shutter height facade 2 threshold 1Individual control1 Bit1.1 switchCT
213Blind/shutter height facade 2 threshold 2Individual control1 Bit1.1 switchCT
214Blind/shutter height facade 2 threshold 3Individual control1 Bit1.1 switchCT
215Slat position facade 2Individual control1 Byte5.1 percentage (0..100%)CT
216Disable facade 2Shading control1 Bit1.1 switchCW
217Shading facade 3Shading control1 Byte5.1 percentage (0..100%)CT
217Shading facade 3Shading control1 Bit1.1 switchCT
218Opening angle facade 3Individual control1 Byte5.3 angle (degrees)CW
219Blind/shutter height, facade 3 positionIndividual control1 Byte5.1 percentage (0..100%)CT
219Blind/shutter height facade 3 threshold 1Individual control1 Bit1.1 switchCT
220Blind/shutter height facade 3 threshold 2Individual control1 Bit1.1 switchCT
221Blind/shutter height facade 3 threshold 3Individual control1 Bit1.1 switchCT
222Slat position facade 3Individual control1 Byte5.1 percentage (0..100%)CT
223Disable facade 3Shading control1 Bit1.1 switchCW
224Shading facade 4Shading control1 Byte5.1 percentage (0..100%)CT
224Shading facade 4Shading control1 Bit1.1 switchCT
225Opening angle facade 4Individual control1 Byte5.3 angle (degrees)CW
226Blind/shutter height, facade 4 positionIndividual control1 Byte5.1 percentage (0..100%)CT
226Blind/shutter height facade 4 threshold 1Individual control1 Bit1.1 switchCT
227Blind/shutter height facade 4 threshold 2Individual control1 Bit1.1 switchCT
228Blind/shutter height facade 4 threshold 3Individual control1 Bit1.1 switchCT
229Slat position facade 4Individual control1 Byte5.1 percentage (0..100%)CT
230Disable facade 4Shading control1 Bit1.1 switchCW
231Shading facade 5Shading control1 Byte5.1 percentage (0..100%)CT
231Shading facade 5Shading control1 Bit1.1 switchCT
232Opening angle facade 5Individual control1 Byte5.3 angle (degrees)CW
233Blind/shutter height, facade 5 positionIndividual control1 Byte5.1 percentage (0..100%)CT
233Blind/shutter height facade 5 threshold 1Individual control1 Bit1.1 switchCT
234Blind/shutter height facade 5 threshold 2Individual control1 Bit1.1 switchCT
235Blind/shutter height facade 5 threshold 3Individual control1 Bit1.1 switchCT
236Slat position facade 5Individual control1 Byte5.1 percentage (0..100%)CT
237Disable facade 5Shading control1 Bit1.1 switchCW
238Shading facade 6Shading control1 Byte5.1 percentage (0..100%)CT
238Shading facade 6Shading control1 Bit1.1 switchCT
239Opening angle facade 6Individual control1 Byte5.3 angle (degrees)CW
240Blind/shutter height, facade 6 positionIndividual control1 Byte5.1 percentage (0..100%)CT
240Blind/shutter height facade 6 threshold 1Individual control1 Bit1.1 switchCT
241Blind/shutter height facade 6 threshold 2Individual control1 Bit1.1 switchCT
242Blind/shutter height facade 6 threshold 3Individual control1 Bit1.1 switchCT
243Slat position facade 6Individual control1 Byte5.1 percentage (0..100%)CT
244Disable facade 6Shading control1 Bit1.1 switchCW
245Shading facade 7Shading control1 Byte5.1 percentage (0..100%)CT
245Shading facade 7Shading control1 Bit1.1 switchCT
246Opening angle facade 7Individual control1 Byte5.3 angle (degrees)CW
247Blind/shutter height, facade 7 positionIndividual control1 Byte5.1 percentage (0..100%)CT
247Blind/shutter height facade 7 threshold 1Individual control1 Bit1.1 switchCT
248Blind/shutter height facade 7 threshold 2Individual control1 Bit1.1 switchCT
249Blind/shutter height facade 7 threshold 3Individual control1 Bit1.1 switchCT
250Slat position facade 7Individual control1 Byte5.1 percentage (0..100%)CT
251Disable facade 7Shading control1 Bit1.1 switchCW
252Shading facade 8Shading control1 Byte5.1 percentage (0..100%)CT
252Shading facade 8Shading control1 Bit1.1 switchCT
253Opening angle facade 8Individual control1 Byte5.3 angle (degrees)CW
254Blind/shutter height, facade 8 positionIndividual control1 Byte5.1 percentage (0..100%)CT
254Blind/shutter height facade 8 threshold 1Individual control1 Bit1.1 switchCT
255Blind/shutter height facade 8 threshold 2Individual control1 Bit1.1 switchCT
256Blind/shutter height facade 8 threshold 3Individual control1 Bit1.1 switchCT
257Slat position facade 8Individual control1 Byte5.1 percentage (0..100%)CT
258Disable facade 8Shading control1 Bit1.1 switchCW
259Time. InputExternal date, time3 Bytes10.1 time of dayCWT
260Date. InputExternal date, time3 Bytes11.1 dateCWT
261Request time / dateExternal date, time1 Bit1.3 enableCT
262Wind sensor unchangedMonitoring1 Bit1.1 switchCT
263Wind direction unchangedMonitoring1 Bit1.1 switchCT
264no wind signalMonitoring1 Bit1.1 switchCT
265Power supply okMonitoring1 Bit1.1 switchCT
266Error messageMonitoring1 ByteCT
267Sensor statusMonitoring2 BytesCT
Parameters (202)
ParameterTypeDefault
Cycl. sending of the monitoring bits (x 10s) (0 = do not send cyclically)unsignedInt 0…1200
Cycl. sending of the measured value (x 10s) (0 = do not send cyclically)unsignedInt 0…1200
Cycl. sending of limiting value 2 (x 10s) (0 = do not send cyclically)unsignedInt 0…1200
Cycl. sending of limiting value 1 (x 10s) (0 = do not send cyclically)unsignedInt 0…1200
Monitoring wind signallistmonitor
Wind speedlistnot activated
Behaviour of disabling objectlistLocking when 0-telegram
Behaviour input 4listnormal
Behaviour input 3listnormal
Behaviour input 2listnormal
Behaviour input 1listnormal
Behaviour outputlistnormal
Type input/outputlistSwitching 1 bit
Temperature sensorlistnot activated
Disabling response upon initializationlistenabled
Disabling moduleslistno disabling module
Send measured value at (10s sending delay)list3% measured value difference
Precipitationlistnot activated
Max. time for "No wind" in hoursunsignedInt 1…18010
Max. time for "Wind speed unchanged" in minutesunsignedInt 1…25510
Max. brightness sensors 1 to 4 and twilightlistnot activated
Max. brightness sensors 1 to 4listnot activated
logic gateslistno logic gates
Hysteresis limiting value 2 in m/slist1 m/s
Hysteresis limiting value 2 in klxlist3 kLux
Hysteresis limiting value 1 in m/slist1 m/s
Hysteresis limiting value 1 in klxlist3 kLux
Brightness sensor 3listnot activated
Brightness sensor 2listnot activated
Brightness sensor 1listnot activated
Monitor power supplylisto .k. = 1, not o.k. = 0
Limiting valueslistnot activated
Sending of limiting value 2 on value changelistNo
Limiting value 2 in m/slist5 m/s (wind speed 3)
Limiting value 2 in klxlist10 kLux
Sending of limiting value 1 on value changelistNo
Limiting value 1 in m/slist5 m/s (wind speed 3)
Limiting value 1 in klxlist10 kLux
External limiting value 2listNo
External limiting value 1listNo
Switch-on delay limiting value 2list3min delay
Switch-on delay limiting value 1list3min delay
Switch-on delay factorunsignedInt 1…1001
Switch-on delay Baselist1 s
Switch-on delaylistno delay
Inputlistinternal input value
Input 4listinternal input value
Input 3listinternal input value
Input 2listinternal input value
Inputlistexternal input value
Input 1listinternal input value
Twilight sensorlistnot activated
Switch-off delay limiting value 2list10min delay
Switch-off delay limiting value 1list10min delay
Switch-off delay factorunsignedInt 1…1001
Switch-off delay Baselist1 s
Switch-off delaylistno delay
cyclic sending of the output (x 10s) (0 = do not send cyclically)unsignedInt 0…1200
Send output atlistEach input event
Type of logic operationlistOR
Number of inputslist2 inputs
Activation limiting value 2 LV=limiting value, hyst.=hysteresislistExceed LV=ON, undershoot LV-hyst.=OFF
Activation limiting value 1 LV=limiting value, hyst.=hysteresislistExceed LV=ON, undershoot LV-hyst.=OFF
Brightness sensor 4listnot activated
Wind directionlistnot activated
Absolute humiditylistnot activated
GPS/Glonasslistnot activated
Air pressurelistnot activated
Relative humiditylistnot activated
Global radiationlistnot activated
Shading controllistnot activated
Comfortlistnot activated
Felt temperaturelistnot activated
Assign input 1listBrightness sensor 1 - LV1
Assign input 2listBrightness sensor 1 - LV1
Assign input 3listBrightness sensor 1 - LV1
Assign input 4listBrightness sensor 1 - LV1
Specification of position and heightlistnot activated
Geographic latitude in °float -90…900
Geographic longitude in °float -180…1800
geographical height in meters above mean sea levelunsignedInt 0…8848250
Basic brightness thresholdlistInternal
Basic brightness for shading in kLuxunsignedInt 3…5010
Hysteresis basic brightness in kLuxunsignedInt 1…303
Cyclical sending of the shading objectslistDo not send cyclically
Switch-on delay, basic brightnesslist3 min delay
Switch-off delay, Switch-off delay, basic brightnesslist10 min delay
Format of the shading objectslist1-bit
Waiting time between shading and slat positionlistNo waiting time
Cyclical sending of the slat position [min]unsignedInt 0…2550
Send slat position onlist10° elevation change
Send blind/shutter height after end of the shadinglistYes
Send slat position after end of the shadinglistYes
Orientation of the facade in °unsignedInt 0…3600
Opening angle to the sunlistInternal
Opening angle in °unsignedInt 0…180150
Type of blind/shutter objectlist1-bit
Activate threshold 1listNo
Sun angle threshold 1 in °unsignedInt 0…9015
Blind/shutter height threshold 1 in %unsignedInt 0…10080
Slat position for max. shading in %unsignedInt 0…100100
Slat position for min. shading in %unsignedInt 0…10050
Disable facade controllistNo
Polarity of disable objectlistLocking when 1-telegram
Behaviour at the beginning of the disabling functionlistNo action
Blind/shutter heightlistNo action
Blind/shutter height value in %unsignedInt 0…1000
Shading objectlistNo action
Slat positionlistNo action
Slat position value in %unsignedInt 0…1000
Behaviour at the end of the disabling functionlistNo action
Monitoringlistnot activated
Offset slat position in %unsignedInt 0…1000
Sun angle threshold 2 in °unsignedInt 0…9015
Blind/shutter height threshold 2 in %unsignedInt 0…10080
Sun angle threshold 3 in °unsignedInt 0…9015
Blind/shutter height threshold 3 in %unsignedInt 0…10080
Activate threshold 2listNo
Activate threshold 3listNo
Assign input internallistBrightness sensor 1 - LV1
Assign input internallistMeasured value wind direction
Assign input internallistMeasured value brightness sensor 1
Max. time for "Wind direction unchanged" in minutesunsignedInt 1…25510
Limiting value 1 in °list0°
Hysteresis in °list10°
Activation arealistMeasured value in area=OFF, Undershoot=ON, Exceed=ON
Switch-on delay area messagelist3min delay
Switch-off delay area messagelist10min delay
Transmit area message on value changelistYes
Cycl. sending of the area message (x 10s) (0 = do not send cyclically)unsignedInt 0…1200
Limiting value 2 in °list90°
Hysteresis limiting value 2 in °list10°
Sending of limiting value 2 on value changelistYes
Text direction northtext
Text direction north easttext
Text direction easttext
Text direction south easttext
Text direction southtext
Text direction south westtext
Text direction westtext
Text direction north westtext
Number of facadesunsignedInt 1…84
Limiting value 1 in luxlist10 lux
Hysteresis limiting value 1 in luxlist10 lux
Limiting value 2 in luxlist10 lux
Hysteresis limiting value 2 in luxlist10 lux
Limiting value 1list10 kLux
Hysteresis limiting value 1list3 kLux
Limiting value 2list10 kLux
Hysteresis limiting value 2list3 kLux
Limiting value 1 in W/m²list900 Watt/m²
Hysteresis limiting value 1 in W/m²list200 Watt/m²
Limiting value 2 in W/m²list900 Watt/m²
Hysteresis limiting value 2 in W/m²list200 Watt/m²
Limiting value 1listON when raining
Hysteresis limiting value 1unsignedInt 0…2550
Limiting value 2listON when raining
Hysteresis limiting value 2unsignedInt 0…2550
Limiting value 1 in °Clist18 °C
Hysteresis limiting value 1 in Klist2 K
Limiting value 2 in °Clist25 °C (77 °F)
Hysteresis limiting value 2 in Klist5 K
Limiting value 1 in %list60%
Hysteresis limiting value 1 in %list10%
Limiting value 2 in %list60%
Hysteresis limiting value 2 in %list10%
Limiting value 1 in hPalist1000 hPa
Hysteresis limiting value 1 in hPalist1 hPa
Limiting value 2 in hPalist1000 hPa
Hysteresis limiting value 2 in hPalist1 hPa
Cycl. sending of the measured values (x 10s) (0 = do not send cyclically)unsignedInt 0…1200
Limiting value 1 in klxunsignedInt 0…2550
Hysteresis limiting value 1 in klxunsignedInt 0…2550
Limiting value 2 in klxunsignedInt 0…2550
Hysteresis limiting value 2 in klxunsignedInt 0…2550
Limiting value 1 in g/m³list30 g/m³
Hysteresis limiting value 1 in g/m³list3 g/m³
Limiting value 2 in g/m³list30 g/m³
Hysteresis limiting value 2 in g/m³list3 g/m³
Limiting value 2 in °Clist18 °C
Hysteresis limiting value 2 in Klist2 K
Cycl. sending of the oppressiveness measured value (x 10s) (0 = do not send cyclically)unsignedInt 0…1200
Limiting value 1 in klxlist45 kLux
Date/timelistInternal clock
Cyclical sending of the sun position [x 10s]unsignedInt 0…2550
Send sun position atlist10° elevation change
Automatic time settinglistNo
Request date and time cyclicallylist1/day
Cyclical sending of date/time intervallist1/minute
Date / time request throughlist1 telegram
Time zone "Internal clock (GPS)"listUTC+1h
Adjustment sensorlistnot activated
Simulationlistnot activated
Shading bit valuelist1
Value of shading byte in %unsignedInt 0…1000
Cycl. sending of the comfort measured value (x 10s) (0 = do not send cyclically)unsignedInt 0…1200
Transmit the oppressiveness measured value on changelistNo
Sending of comfort value on value changelistNo
Adjustment of the tolerance rangelistLevel 3: Standard
Send request date/time throughlist1 telegram
Activate wind area signallistNo
DPT of measured valuelist16 bit value, DPT 7.001

Version history

ApplicationApp noFingerprintFirst seenSizeFile
Weather Station 3.0 latest$B00D0ED82026-11-25333 KBDownload
Weather Station 2.7$B00DD7CC2026-11-25287 KBDownload
Weather Station 2.3$B00D49C42026-11-25284 KBDownload
Weather Station 2.1$B00D85F72026-11-25186 KBDownload

About this file

This is the official ETS product database for the Somfy Weather Station KNX (1870932), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.