Siemens 5WG1525-1DB11 Switch/dimming actuator N 525D11, 2x DALI Broadcast

Switch/dimming actuator N 525D11, 2x DALI Broadcast 5WG1525-1DB11

Siemens · Order number 5WG1525-1DB11 · Lighting › Switching/Dimming Actuator › N-Devices › N 525D11

Switch/dimming actuator N 525D11, 2x DALI Broadcast

Download .knxprod 07 B0 A2 Switch-/Dimm actuator 2-fold DALI 9A1701 0.1 · 361 KB

Product

ManufacturerSiemens
Product nameSwitch/dimming actuator N 525D11, 2x DALI Broadcast
Order number5WG1525-1DB11
HardwareHardwareEntry.0.9A17
MediumTwisted Pair
Bus current (mA)5
Rail mountedYes
RegistrationRegistered · 2019-11-27
Languagesen-US, de-DE, it-IT, fr-FR, es-ES, sv-SE
Catalog entryM-0001_H-hp.5F00336-1_HP-9A17-01-3201_CI-5WG1525.2D1DB11-1
Fingerprint3201
SHA-256865a5eff83716f2ec6587a054b931eb6eb748572d10a709e680b16a8e2faf4b5
First seen2026-11-25
Markets59 markets

Application program: 07 B0 A2 Switch-/Dimm actuator 2-fold DALI 9A1701 0.1

Application number$9A17
Version0.1
Mask versionMV-07B0 (System B)
KNX Data SecureNo
Minimum ETS version5.0
Parameters1207
Group objects774
Group objects (774)
NoNameFunctionSizeDPTFlags
1Status device functionOk / Defect1 Bit1.5 alarmCRT
2Send status valuesRequest1 Bit1.17 triggerCW
3A SwitchingOn / Off1 Bit1.1 switchCW
4A Control ValueValue1 Byte5.10 counter pulses (0..255)CW
4A Control ValueValue2 Bytes9.1 temperature (°C)CW
4A Control ValueValue1 Byte5.1 percentage (0..100%)CW
4A Control ValueValue2 Bytes9.4 lux (Lux)CW
4A Control ValueValue2 Bytes9.21 current (mA)CW
4A Control ValueValue2 Bytes9.24 power (kW)CW
4A Control ValueValue4 Bytes14.56 power (W)CW
5A DimmingBrighter / darker4 Bit3.7 dimming controlCW
6A Dimming value 18-bit value1 Byte5.1 percentage (0..100%)CW
7A Dimming value 28-bit value1 Byte5.1 percentage (0..100%)CW
8A Dimming value 1 / timeDimming value + time3 Bytes225.1 scaling speedCW
10A Status switchingOn / Off1 Bit1.1 switchCRT
11A Status dimming value8-bit value1 Byte5.1 percentage (0..100%)CRT
12A Minimum dimming valueSet / Request value1 Byte5.1 percentage (0..100%)CRW
13A Maximum dimming valueSet / Request value1 Byte5.1 percentage (0..100%)CRW
14A Dimming time for switchingSet / Request dimming time2 Bytes7.4 time (100 ms)CRW
15A Dimming time for dimmingSet / Request dimming time2 Bytes7.4 time (100 ms)CRW
16A Dimming time for dimming value 1Set / Request dimming time2 Bytes7.4 time (100 ms)CRW
17A Dimming time for dimming value 2Set / Request dimming time2 Bytes7.4 time (100 ms)CRW
18A Logic operation 1On / Off1 Bit1.1 switchCW
19A Logic operation 2On / Off1 Bit1.1 switchCW
20A Central SwitchingOn / Off1 Bit1.1 switchCW
21A 8-bit sceneRecall / store1 Byte18.1 scene controlCW
22A Scene value/timeValue / Time3 BytesCW
23A Night modeOn / Off1 Bit1.3 enableCW
24A Night mode timerON time (seconds)2 Bytes7.5 time (s)CRW
25A Day mode timerON time 1 (seconds)2 Bytes7.5 time (s)CRW
27A Pre-warning expiration of timer periodOn / Off1 Bit1.1 switchCRT
28A Lock TimerOn / Off1 Bit1.3 enableCW
29A Override 1, Permanent OFFOn / Off1 Bit1.3 enableCW
29A Override 1, Manual ONOn / Off1 Bit1.3 enableCW
29A Override 1, LockOn / Off1 Bit1.3 enableCW
29A Override 1, Central ControlOn / Off1 Bit1.3 enableCW
29A Override 1, User-defined ControlOn / Off1 Bit1.3 enableCW
30A Override 1, Lock, ControlValue2 Bytes9.21 current (mA)CW
30A Override 1, Central Control, ControlValue2 Bytes9.21 current (mA)CW
30A Override 1, User-defined Control, Control ValueValue2 Bytes9.21 current (mA)CW
30A Override 1, Permanent OFF, Control ValueValue2 Bytes9.24 power (kW)CW
30A Override 1, Manual ON, Control ValueValue2 Bytes9.24 power (kW)CW
30A Override 1, Lock, ControlValue2 Bytes9.24 power (kW)CW
30A Override 1, Central Control, ControlValue4 Bytes14.56 power (W)CW
30A Override 1, User-defined Control, Control ValueValue2 Bytes9.24 power (kW)CW
30A Override 1, Permanent OFF, Control ValueValue4 Bytes14.56 power (W)CW
30A Override 1, Manual ON, Control ValueValue4 Bytes14.56 power (W)CW
30A Override 1, Lock, ControlValue4 Bytes14.56 power (W)CW
30A Override 1, Manual ON, Control ValueValue2 Bytes9.21 current (mA)CW
30A Override 1, User-defined Control, Control ValueValue4 Bytes14.56 power (W)CW
30A Override 1, Central Control, ControlValue2 Bytes9.24 power (kW)CW
30A Override 1, Permanent OFF, Control ValueValue2 Bytes9.21 current (mA)CW
30A Override 1, Lock, ControlValue2 Bytes9.4 lux (Lux)CW
30A Override 1, Central Control, ControlValue2 Bytes9.4 lux (Lux)CW
30A Override 1, Permanent OFF, Control ValueValue1 Byte5.10 counter pulses (0..255)CW
30A Override 1, Manual ON, Control ValueValue1 Byte5.10 counter pulses (0..255)CW
30A Override 1, Lock, ControlValue1 Byte5.10 counter pulses (0..255)CW
30A Override 1, Central Control, ControlValue1 Byte5.10 counter pulses (0..255)CW
30A Override 1, User-defined Control, Control ValueValue1 Byte5.10 counter pulses (0..255)CW
30A Override 1, Permanent OFF, Control ValueValue2 Bytes9.1 temperature (°C)CW
30A Override 1, Manual ON, Control ValueValue2 Bytes9.1 temperature (°C)CW
30A Override 1, Central Control, ControlValue2 Bytes9.1 temperature (°C)CW
30A Override 1, Lock, ControlValue2 Bytes9.1 temperature (°C)CW
30A Override 1, Permanent OFF, Control ValueValue1 Byte5.1 percentage (0..100%)CW
30A Override 1, Manual ON, Control ValueValue1 Byte5.1 percentage (0..100%)CW
30A Override 1, Lock, ControlValue1 Byte5.1 percentage (0..100%)CW
30A Override 1, Central Control, ControlValue1 Byte5.1 percentage (0..100%)CW
30A Override 1, User-defined Control, Control ValueValue1 Byte5.1 percentage (0..100%)CW
30A Override 1, Permanent OFF, Control ValueValue2 Bytes9.4 lux (Lux)CW
30A Override 1, Manual ON, Control ValueValue2 Bytes9.4 lux (Lux)CW
30A Override 1, User-defined Control, Control ValueValue2 Bytes9.1 temperature (°C)CW
30A Override 1, User-defined Control, Control ValueValue2 Bytes9.4 lux (Lux)CW
31A Override 1, Forced ControlOn / Off2 Bit2.1 switch controlCW
32A Override 1, Central Control, StatusOn / Off1 Bit1.2 booleanCRT
32A Override 1, Forced Control, StatusOn / Off1 Bit1.2 booleanCRT
32A Override 1, User-defined Control, StatusOn / Off1 Bit1.2 booleanCRT
32A Override 1, Lock, StatusOn / Off1 Bit1.2 booleanCRT
32A Override 1, Permanent-OFF, StatusOn / Off1 Bit1.2 booleanCRT
32A Override 1, Manual ON, StatusOn / Off1 Bit1.2 booleanCRT
33A Override 2, User-defined ControlOn / Off1 Bit1.3 enableCW
33A Override 2, Central ControlOn / Off1 Bit1.3 enableCW
33A Override 2, LockOn / Off1 Bit1.3 enableCW
33A Override 2, Manual ONOn / Off1 Bit1.3 enableCW
33A Override 2, Permanent OFFOn / Off1 Bit1.3 enableCW
34A Override 2, Lock, ControlValue2 Bytes9.21 current (mA)CW
34A Override 2, Central Control, ControlValue2 Bytes9.21 current (mA)CW
34A Override 2, User-defined Control, Control ValueValue2 Bytes9.21 current (mA)CW
34A Override 2, Permanent OFF, Control ValueValue2 Bytes9.24 power (kW)CW
34A Override 2, Manual ON, Control ValueValue2 Bytes9.24 power (kW)CW
34A Override 2, Lock, ControlValue2 Bytes9.24 power (kW)CW
34A Override 2, Manual ON, Control ValueValue4 Bytes14.56 power (W)CW
34A Override 2, User-defined Control, Control ValueValue2 Bytes9.24 power (kW)CW
34A Override 2, Permanent OFF, Control ValueValue4 Bytes14.56 power (W)CW
34A Override 2, Lock, ControlValue4 Bytes14.56 power (W)CW
34A Override 2, Central Control, ControlValue4 Bytes14.56 power (W)CW
34A Override 2, User-defined Control, Control ValueValue4 Bytes14.56 power (W)CW
34A Override 2, Manual ON, Control ValueValue2 Bytes9.21 current (mA)CW
34A Override 2, Central Control, ControlValue2 Bytes9.24 power (kW)CW
34A Override 2, Permanent OFF, Control ValueValue2 Bytes9.21 current (mA)CW
34A Override 2, Lock, ControlValue2 Bytes9.4 lux (Lux)CW
34A Override 2, Central Control, ControlValue2 Bytes9.4 lux (Lux)CW
34A Override 2, Permanent OFF, Control ValueValue1 Byte5.10 counter pulses (0..255)CW
34A Override 2, Manual ON, Control ValueValue1 Byte5.10 counter pulses (0..255)CW
34A Override 2, Lock, ControlValue1 Byte5.10 counter pulses (0..255)CW
34A Override 2, Central Control, ControlValue1 Byte5.10 counter pulses (0..255)CW
34A Override 2, User-defined Control, Control ValueValue1 Byte5.10 counter pulses (0..255)CW
34A Override 2, Permanent OFF, Control ValueValue2 Bytes9.1 temperature (°C)CW
34A Override 2, Manual ON, Control ValueValue2 Bytes9.1 temperature (°C)CW
34A Override 2, Lock, ControlValue2 Bytes9.1 temperature (°C)CW
34A Override 2, Central Control, ControlValue2 Bytes9.1 temperature (°C)CW
34A Override 2, User-defined Control, Control ValueValue2 Bytes9.4 lux (Lux)CW
34A Override 2, Permanent OFF, Control ValueValue1 Byte5.1 percentage (0..100%)CW
34A Override 2, Manual ON, Control ValueValue1 Byte5.1 percentage (0..100%)CW
34A Override 2, Lock, ControlValue1 Byte5.1 percentage (0..100%)CW
34A Override 2, Central Control, ControlValue1 Byte5.1 percentage (0..100%)CW
34A Override 2, User-defined Control, Control ValueValue1 Byte5.1 percentage (0..100%)CW
34A Override 2, Permanent OFF, Control ValueValue2 Bytes9.4 lux (Lux)CW
34A Override 2, Manual ON, Control ValueValue2 Bytes9.4 lux (Lux)CW
34A Override 2, User-defined Control, Control ValueValue2 Bytes9.1 temperature (°C)CW
35A Override 2, Forced ControlOn / Off2 Bit2.1 switch controlCW
36A Override 2, Forced Control, StatusOn / Off1 Bit1.2 booleanCRT
36A Override 2, User-defined Control, StatusOn / Off1 Bit1.2 booleanCRT
36A Override 2, Central Control, StatusOn / Off1 Bit1.2 booleanCRT
36A Override 2, Lock, StatusOn / Off1 Bit1.2 booleanCRT
36A Override 2, Manual ON, StatusOn / Off1 Bit1.2 booleanCRT
36A Override 2, Permanent-OFF, StatusOn / Off1 Bit1.2 booleanCRT
37A Override 3, Permanent OFFOn / Off1 Bit1.3 enableCW
37A Override 3, Manual ONOn / Off1 Bit1.3 enableCW
37A Override 3, LockOn / Off1 Bit1.3 enableCW
37A Override 3, Central ControlOn / Off1 Bit1.3 enableCW
37A Override 3, User-defined ControlOn / Off1 Bit1.3 enableCW
38A Override 3, User-defined Control, Control ValueValue4 Bytes14.56 power (W)CW
38A Override 3, Central Control, ControlValue4 Bytes14.56 power (W)CW
38A Override 3, Lock, ControlValue4 Bytes14.56 power (W)CW
38A Override 3, Manual ON, Control ValueValue4 Bytes14.56 power (W)CW
38A Override 3, Manual ON, Control ValueValue2 Bytes9.21 current (mA)CW
38A Override 3, User-defined Control, Control ValueValue2 Bytes9.24 power (kW)CW
38A Override 3, Central Control, ControlValue2 Bytes9.24 power (kW)CW
38A Override 3, Lock, ControlValue2 Bytes9.24 power (kW)CW
38A Override 3, Manual ON, Control ValueValue2 Bytes9.24 power (kW)CW
38A Override 3, Permanent OFF, Control ValueValue2 Bytes9.24 power (kW)CW
38A Override 3, User-defined Control, Control ValueValue2 Bytes9.21 current (mA)CW
38A Override 3, Central Control, ControlValue2 Bytes9.21 current (mA)CW
38A Override 3, Lock, ControlValue2 Bytes9.21 current (mA)CW
38A Override 3, Permanent OFF, Control ValueValue4 Bytes14.56 power (W)CW
38A Override 3, Permanent OFF, Control ValueValue2 Bytes9.21 current (mA)CW
38A Override 3, Central Control, ControlValue2 Bytes9.4 lux (Lux)CW
38A Override 3, Permanent OFF, Control ValueValue1 Byte5.10 counter pulses (0..255)CW
38A Override 3, Manual ON, Control ValueValue1 Byte5.10 counter pulses (0..255)CW
38A Override 3, Lock, ControlValue1 Byte5.10 counter pulses (0..255)CW
38A Override 3, Central Control, ControlValue1 Byte5.10 counter pulses (0..255)CW
38A Override 3, User-defined Control, Control ValueValue1 Byte5.10 counter pulses (0..255)CW
38A Override 3, Permanent OFF, Control ValueValue2 Bytes9.1 temperature (°C)CW
38A Override 3, Manual ON, Control ValueValue2 Bytes9.1 temperature (°C)CW
38A Override 3, Central Control, ControlValue2 Bytes9.1 temperature (°C)CW
38A Override 3, Lock, ControlValue2 Bytes9.1 temperature (°C)CW
38A Override 3, Permanent OFF, Control ValueValue1 Byte5.1 percentage (0..100%)CW
38A Override 3, Manual ON, Control ValueValue1 Byte5.1 percentage (0..100%)CW
38A Override 3, Lock, ControlValue1 Byte5.1 percentage (0..100%)CW
38A Override 3, Central Control, ControlValue1 Byte5.1 percentage (0..100%)CW
38A Override 3, User-defined Control, Control ValueValue1 Byte5.1 percentage (0..100%)CW
38A Override 3, Permanent OFF, Control ValueValue2 Bytes9.4 lux (Lux)CW
38A Override 3, Manual ON, Control ValueValue2 Bytes9.4 lux (Lux)CW
38A Override 3, Lock, ControlValue2 Bytes9.4 lux (Lux)CW
38A Override 3, User-defined Control, Control ValueValue2 Bytes9.1 temperature (°C)CW
38A Override 3, User-defined Control, Control ValueValue2 Bytes9.4 lux (Lux)CW
39A Override 3, Forced ControlOn / Off2 Bit2.1 switch controlCW
40A Override 3, Central Control, StatusOn / Off1 Bit1.2 booleanCRT
40A Override 3, Forced Control, StatusOn / Off1 Bit1.2 booleanCRT
40A Override 3, User-defined Control, StatusOn / Off1 Bit1.2 booleanCRT
40A Override 3, Lock, StatusOn / Off1 Bit1.2 booleanCRT
40A Override 3, Permanent-OFF, StatusOn / Off1 Bit1.2 booleanCRT
40A Override 3, Manual ON, StatusOn / Off1 Bit1.2 booleanCRT
41A Override 4, User-defined ControlOn / Off1 Bit1.3 enableCW
41A Override 4, Central ControlOn / Off1 Bit1.3 enableCW
41A Override 4, LockOn / Off1 Bit1.3 enableCW
41A Override 4, Manual ONOn / Off1 Bit1.3 enableCW
41A Override 4, Permanent OFFOn / Off1 Bit1.3 enableCW
42A Override 4, Lock, ControlValue2 Bytes9.21 current (mA)CW
42A Override 4, Central Control, ControlValue2 Bytes9.21 current (mA)CW
42A Override 4, User-defined Control, Control ValueValue2 Bytes9.21 current (mA)CW
42A Override 4, Permanent OFF, Control ValueValue2 Bytes9.24 power (kW)CW
42A Override 4, Manual ON, Control ValueValue2 Bytes9.24 power (kW)CW
42A Override 4, Lock, ControlValue2 Bytes9.24 power (kW)CW
42A Override 4, Manual ON, Control ValueValue4 Bytes14.56 power (W)CW
42A Override 4, User-defined Control, Control ValueValue2 Bytes9.24 power (kW)CW
42A Override 4, Permanent OFF, Control ValueValue4 Bytes14.56 power (W)CW
42A Override 4, Lock, ControlValue4 Bytes14.56 power (W)CW
42A Override 4, Central Control, ControlValue4 Bytes14.56 power (W)CW
42A Override 4, User-defined Control, Control ValueValue4 Bytes14.56 power (W)CW
42A Override 4, Manual ON, Control ValueValue2 Bytes9.21 current (mA)CW
42A Override 4, Central Control, ControlValue2 Bytes9.24 power (kW)CW
42A Override 4, Permanent OFF, Control ValueValue2 Bytes9.21 current (mA)CW
42A Override 4, User-defined Control, Control ValueValue2 Bytes9.4 lux (Lux)CW
42A Override 4, Central Control, ControlValue2 Bytes9.4 lux (Lux)CW
42A Override 4, Permanent OFF, Control ValueValue1 Byte5.10 counter pulses (0..255)CW
42A Override 4, Manual ON, Control ValueValue1 Byte5.10 counter pulses (0..255)CW
42A Override 4, Lock, ControlValue1 Byte5.10 counter pulses (0..255)CW
42A Override 4, Central Control, ControlValue1 Byte5.10 counter pulses (0..255)CW
42A Override 4, User-defined Control, Control ValueValue1 Byte5.10 counter pulses (0..255)CW
42A Override 4, Permanent OFF, Control ValueValue2 Bytes9.1 temperature (°C)CW
42A Override 4, Manual ON, Control ValueValue2 Bytes9.1 temperature (°C)CW
42A Override 4, Central Control, ControlValue2 Bytes9.1 temperature (°C)CW
42A Override 4, Lock, ControlValue2 Bytes9.1 temperature (°C)CW
42A Override 4, Permanent OFF, Control ValueValue1 Byte5.1 percentage (0..100%)CW
42A Override 4, Manual ON, Control ValueValue1 Byte5.1 percentage (0..100%)CW
42A Override 4, Lock, ControlValue1 Byte5.1 percentage (0..100%)CW
42A Override 4, Central Control, ControlValue1 Byte5.1 percentage (0..100%)CW
42A Override 4, User-defined Control, Control ValueValue1 Byte5.1 percentage (0..100%)CW
42A Override 4, Permanent OFF, Control ValueValue2 Bytes9.4 lux (Lux)CW
42A Override 4, Manual ON, Control ValueValue2 Bytes9.4 lux (Lux)CW
42A Override 4, Lock, ControlValue2 Bytes9.4 lux (Lux)CW
42A Override 4, User-defined Control, Control ValueValue2 Bytes9.1 temperature (°C)CW
43A Override 4, Forced ControlOn / Off2 Bit2.1 switch controlCW
44A Override 4, User-defined Control, StatusOn / Off1 Bit1.2 booleanCRT
44A Override 4, Forced Control, StatusOn / Off1 Bit1.2 booleanCRT
44A Override 4, Central Control, StatusOn / Off1 Bit1.2 booleanCRT
44A Override 4, Lock, StatusOn / Off1 Bit1.2 booleanCRT
44A Override 4, Manual ON, StatusOn / Off1 Bit1.2 booleanCRT
44A Override 4, Permanent-OFF, StatusOn / Off1 Bit1.2 booleanCRT
45A Override 5, User-defined ControlOn / Off1 Bit1.3 enableCW
45A Override 5, Central ControlOn / Off1 Bit1.3 enableCW
45A Override 5, LockOn / Off1 Bit1.3 enableCW
45A Override 5, Manual ONOn / Off1 Bit1.3 enableCW
45A Override 5, Permanent OFFOn / Off1 Bit1.3 enableCW
46A Override 5, Lock, ControlValue2 Bytes9.21 current (mA)CW
46A Override 5, Central Control, ControlValue2 Bytes9.21 current (mA)CW
46A Override 5, User-defined Control, Control ValueValue2 Bytes9.21 current (mA)CW
46A Override 5, Permanent OFF, Control ValueValue2 Bytes9.24 power (kW)CW
46A Override 5, Manual ON, Control ValueValue2 Bytes9.24 power (kW)CW
46A Override 5, Lock, ControlValue2 Bytes9.24 power (kW)CW
46A Override 5, Manual ON, Control ValueValue4 Bytes14.56 power (W)CW
46A Override 5, User-defined Control, Control ValueValue2 Bytes9.24 power (kW)CW
46A Override 5, Permanent OFF, Control ValueValue4 Bytes14.56 power (W)CW
46A Override 5, Manual ON, Control ValueValue2 Bytes9.21 current (mA)CW
46A Override 5, Lock, ControlValue4 Bytes14.56 power (W)CW
46A Override 5, Central Control, ControlValue4 Bytes14.56 power (W)CW
46A Override 5, User-defined Control, Control ValueValue4 Bytes14.56 power (W)CW
46A Override 5, Central Control, ControlValue2 Bytes9.24 power (kW)CW
46A Override 5, Permanent OFF, Control ValueValue2 Bytes9.21 current (mA)CW
46A Override 5, User-defined Control, Control ValueValue2 Bytes9.4 lux (Lux)CW
46A Override 5, Central Control, ControlValue2 Bytes9.4 lux (Lux)CW
46A Override 5, Permanent OFF, Control ValueValue1 Byte5.10 counter pulses (0..255)CW
46A Override 5, Manual ON, Control ValueValue1 Byte5.10 counter pulses (0..255)CW
46A Override 5, Lock, ControlValue1 Byte5.10 counter pulses (0..255)CW
46A Override 5, Central Control, ControlValue1 Byte5.10 counter pulses (0..255)CW
46A Override 5, User-defined Control, Control ValueValue1 Byte5.10 counter pulses (0..255)CW
46A Override 5, Permanent OFF, Control ValueValue2 Bytes9.1 temperature (°C)CW
46A Override 5, Manual ON, Control ValueValue2 Bytes9.1 temperature (°C)CW
46A Override 5, Central Control, ControlValue2 Bytes9.1 temperature (°C)CW
46A Override 5, Lock, ControlValue2 Bytes9.1 temperature (°C)CW
46A Override 5, Permanent OFF, Control ValueValue1 Byte5.1 percentage (0..100%)CW
46A Override 5, Manual ON, Control ValueValue1 Byte5.1 percentage (0..100%)CW
46A Override 5, Lock, ControlValue1 Byte5.1 percentage (0..100%)CW
46A Override 5, Central Control, ControlValue1 Byte5.1 percentage (0..100%)CW
46A Override 5, User-defined Control, Control ValueValue1 Byte5.1 percentage (0..100%)CW
46A Override 5, Permanent OFF, Control ValueValue2 Bytes9.4 lux (Lux)CW
46A Override 5, Manual ON, Control ValueValue2 Bytes9.4 lux (Lux)CW
46A Override 5, Lock, ControlValue2 Bytes9.4 lux (Lux)CW
46A Override 5, User-defined Control, Control ValueValue2 Bytes9.1 temperature (°C)CW
47A Override 5, Forced ControlOn / Off2 Bit2.1 switch controlCW
48A Override 5, User-defined Control, StatusOn / Off1 Bit1.2 booleanCRT
48A Override 5, Forced Control, StatusOn / Off1 Bit1.2 booleanCRT
48A Override 5, Central Control, StatusOn / Off1 Bit1.2 booleanCRT
48A Override 5, Lock, StatusOn / Off1 Bit1.2 booleanCRT
48A Override 5, Manual ON, StatusOn / Off1 Bit1.2 booleanCRT
48A Override 5, Permanent-OFF, StatusOn / Off1 Bit1.2 booleanCRT
49A Override 6, User-defined ControlOn / Off1 Bit1.3 enableCW
49A Override 6, Central ControlOn / Off1 Bit1.3 enableCW
49A Override 6, LockOn / Off1 Bit1.3 enableCW
49A Override 6, Manual ONOn / Off1 Bit1.3 enableCW
49A Override 6, Permanent OFFOn / Off1 Bit1.3 enableCW
50A Override 6, Central Control, ControlValue2 Bytes9.21 current (mA)CW
50A Override 6, User-defined Control, Control ValueValue2 Bytes9.21 current (mA)CW
50A Override 6, Permanent OFF, Control ValueValue2 Bytes9.24 power (kW)CW
50A Override 6, Manual ON, Control ValueValue2 Bytes9.24 power (kW)CW
50A Override 6, Lock, ControlValue2 Bytes9.24 power (kW)CW
50A Override 6, Central Control, ControlValue2 Bytes9.24 power (kW)CW
50A Override 6, Manual ON, Control ValueValue4 Bytes14.56 power (W)CW
50A Override 6, Permanent OFF, Control ValueValue4 Bytes14.56 power (W)CW
50A Override 6, Manual ON, Control ValueValue2 Bytes9.21 current (mA)CW
50A Override 6, Lock, ControlValue4 Bytes14.56 power (W)CW
50A Override 6, Central Control, ControlValue4 Bytes14.56 power (W)CW
50A Override 6, User-defined Control, Control ValueValue4 Bytes14.56 power (W)CW
50A Override 6, User-defined Control, Control ValueValue2 Bytes9.24 power (kW)CW
50A Override 6, Permanent OFF, Control ValueValue2 Bytes9.21 current (mA)CW
50A Override 6, Lock, ControlValue2 Bytes9.21 current (mA)CW
50A Override 6, Central Control, ControlValue2 Bytes9.4 lux (Lux)CW
50A Override 6, Permanent OFF, Control ValueValue1 Byte5.10 counter pulses (0..255)CW
50A Override 6, Manual ON, Control ValueValue1 Byte5.10 counter pulses (0..255)CW
50A Override 6, Lock, ControlValue1 Byte5.10 counter pulses (0..255)CW
50A Override 6, Central Control, ControlValue1 Byte5.10 counter pulses (0..255)CW
50A Override 6, User-defined Control, Control ValueValue1 Byte5.10 counter pulses (0..255)CW
50A Override 6, Permanent OFF, Control ValueValue2 Bytes9.1 temperature (°C)CW
50A Override 6, Manual ON, Control ValueValue2 Bytes9.1 temperature (°C)CW
50A Override 6, Lock, ControlValue2 Bytes9.1 temperature (°C)CW
50A Override 6, User-defined Control, Control ValueValue2 Bytes9.1 temperature (°C)CW
50A Override 6, Central Control, ControlValue2 Bytes9.1 temperature (°C)CW
50A Override 6, Manual ON, Control ValueValue1 Byte5.1 percentage (0..100%)CW
50A Override 6, Lock, ControlValue1 Byte5.1 percentage (0..100%)CW
50A Override 6, Central Control, ControlValue1 Byte5.1 percentage (0..100%)CW
50A Override 6, User-defined Control, Control ValueValue1 Byte5.1 percentage (0..100%)CW
50A Override 6, Permanent OFF, Control ValueValue2 Bytes9.4 lux (Lux)CW
50A Override 6, Manual ON, Control ValueValue2 Bytes9.4 lux (Lux)CW
50A Override 6, User-defined Control, Control ValueValue2 Bytes9.4 lux (Lux)CW
50A Override 6, Lock, ControlValue2 Bytes9.4 lux (Lux)CW
50A Override 6, Permanent OFF, Control ValueValue1 Byte5.1 percentage (0..100%)CW
51A Override 6, Forced ControlOn / Off2 Bit2.1 switch controlCW
52A Override 6, User-defined Control, StatusOn / Off1 Bit1.2 booleanCRT
52A Override 6, Forced Control, StatusOn / Off1 Bit1.2 booleanCRT
52A Override 6, Central Control, StatusOn / Off1 Bit1.2 booleanCRT
52A Override 6, Manual ON, StatusOn / Off1 Bit1.2 booleanCRT
52A Override 6, Permanent-OFF, StatusOn / Off1 Bit1.2 booleanCRT
52A Override 6, Lock, StatusOn / Off1 Bit1.2 booleanCRT
53A Override 7, Central ControlOn / Off1 Bit1.3 enableCW
53A Override 7, LockOn / Off1 Bit1.3 enableCW
53A Override 7, Manual ONOn / Off1 Bit1.3 enableCW
53A Override 7, Permanent OFFOn / Off1 Bit1.3 enableCW
53A Override 7, User-defined ControlOn / Off1 Bit1.3 enableCW
54A Override 7, Manual ON, Control ValueValue2 Bytes9.21 current (mA)CW
54A Override 7, Central Control, ControlValue2 Bytes9.21 current (mA)CW
54A Override 7, User-defined Control, Control ValueValue2 Bytes9.21 current (mA)CW
54A Override 7, Permanent OFF, Control ValueValue2 Bytes9.24 power (kW)CW
54A Override 7, Manual ON, Control ValueValue2 Bytes9.24 power (kW)CW
54A Override 7, Lock, ControlValue2 Bytes9.24 power (kW)CW
54A Override 7, Permanent OFF, Control ValueValue4 Bytes14.56 power (W)CW
54A Override 7, User-defined Control, Control ValueValue2 Bytes9.24 power (kW)CW
54A Override 7, Manual ON, Control ValueValue4 Bytes14.56 power (W)CW
54A Override 7, Lock, ControlValue4 Bytes14.56 power (W)CW
54A Override 7, Central Control, ControlValue4 Bytes14.56 power (W)CW
54A Override 7, User-defined Control, Control ValueValue4 Bytes14.56 power (W)CW
54A Override 7, Central Control, ControlValue2 Bytes9.24 power (kW)CW
54A Override 7, Permanent OFF, Control ValueValue2 Bytes9.21 current (mA)CW
54A Override 7, Lock, ControlValue2 Bytes9.21 current (mA)CW
54A Override 7, Central Control, ControlValue2 Bytes9.4 lux (Lux)CW
54A Override 7, Permanent OFF, Control ValueValue1 Byte5.10 counter pulses (0..255)CW
54A Override 7, Manual ON, Control ValueValue1 Byte5.10 counter pulses (0..255)CW
54A Override 7, Lock, ControlValue1 Byte5.10 counter pulses (0..255)CW
54A Override 7, Central Control, ControlValue1 Byte5.10 counter pulses (0..255)CW
54A Override 7, User-defined Control, Control ValueValue1 Byte5.10 counter pulses (0..255)CW
54A Override 7, Permanent OFF, Control ValueValue2 Bytes9.1 temperature (°C)CW
54A Override 7, Manual ON, Control ValueValue2 Bytes9.1 temperature (°C)CW
54A Override 7, User-defined Control, Control ValueValue2 Bytes9.4 lux (Lux)CW
54A Override 7, Central Control, ControlValue2 Bytes9.1 temperature (°C)CW
54A Override 7, Lock, ControlValue2 Bytes9.1 temperature (°C)CW
54A Override 7, Permanent OFF, Control ValueValue1 Byte5.1 percentage (0..100%)CW
54A Override 7, Manual ON, Control ValueValue1 Byte5.1 percentage (0..100%)CW
54A Override 7, Lock, ControlValue1 Byte5.1 percentage (0..100%)CW
54A Override 7, Central Control, ControlValue1 Byte5.1 percentage (0..100%)CW
54A Override 7, User-defined Control, Control ValueValue1 Byte5.1 percentage (0..100%)CW
54A Override 7, Permanent OFF, Control ValueValue2 Bytes9.4 lux (Lux)CW
54A Override 7, Manual ON, Control ValueValue2 Bytes9.4 lux (Lux)CW
54A Override 7, Lock, ControlValue2 Bytes9.4 lux (Lux)CW
54A Override 7, User-defined Control, Control ValueValue2 Bytes9.1 temperature (°C)CW
55A Override 7, Forced ControlOn / Off2 Bit2.1 switch controlCW
56A Override 7, Forced Control, StatusOn / Off1 Bit1.2 booleanCRT
56A Override 7, Central Control, StatusOn / Off1 Bit1.2 booleanCRT
56A Override 7, User-defined Control, StatusOn / Off1 Bit1.2 booleanCRT
56A Override 7, Manual ON, StatusOn / Off1 Bit1.2 booleanCRT
56A Override 7, Permanent-OFF, StatusOn / Off1 Bit1.2 booleanCRT
56A Override 7, Lock, StatusOn / Off1 Bit1.2 booleanCRT
57A Overrides status1 = Active1 Bit1.2 booleanCRT
58A Global dimming max. limit8-bit value1 Byte5.1 percentage (0..100%)CW
59A Direct operation lockOn / Off1 Bit1.3 enableCW
60A Status direct operationOn / Off1 Bit1.2 booleanCRT
63A Dim color temperatureWarmer / colder4 Bit3.7 dimming controlCW
64A Color temperature value16-bit value2 Bytes7.600 absolute colour temperature (K)CW
65A Dim brightness and color temperatureBrighter / darker, warmer / colder3 Bytes250.600 brightness colour temperature controlCW
66A Dimming value 1 / color temperature value / dimming timeDimming value + color temperature value + dimming time6 Bytes249.600 brightness colour temperature transitionCW
67A Dimming time for dimming the color temperatureSet / Request dimming time2 Bytes7.4 time (100 ms)CRW
68A Dimming time for color temperature valueSet / Request dimming time2 Bytes7.4 time (100 ms)CRW
69A Global color temperature max. limit16-bit value2 Bytes7.600 absolute colour temperature (K)CW
70A Minimum color temperature valueSet / Request value2 Bytes7.600 absolute colour temperature (K)CRW
71A Maximum color temperature valueSet / Request value2 Bytes7.600 absolute colour temperature (K)CRW
72A Status color temperature value16-bit value2 Bytes7.600 absolute colour temperature (K)CRT
73A Number of switching cyclesValue (in cycles)4 Bytes12.1 counter pulses (unsigned)CRT
74A Number of switching cyclesSet Value (in cycles)4 Bytes12.1 counter pulses (unsigned)CW
75A Threshold for switching cyclesSet / Request value (in cycles)4 Bytes12.1 counter pulses (unsigned)CRW
76A Exceedance of threshold for switching cyclesOn / Off1 Bit1.2 booleanCRT
77A Operating hoursValue (in hours)4 Bytes12.1 counter pulses (unsigned)CRT
78A Operating hoursValue (in seconds)4 Bytes13.100 time lag (s)CRT
79A Operating hoursSet Value4 Bytes12.1 counter pulses (unsigned)CW
80A Threshold for operating hoursSet / Request value4 Bytes12.1 counter pulses (unsigned)CRW
81A Exceedance of threshold for operating hoursOn / Off1 Bit1.2 booleanCRT
90A Status failure incorrect voltage on DALI line1 = Failure1 Bit1.2 booleanCRT
91A Status failure lights defective1 = Failure1 Bit1.2 booleanCRT
92A Status failure short circuit DALI line1 = Failure1 Bit1.2 booleanCRT
93A Status failure no ECG found1 = Failure1 Bit1.2 booleanCRT
96B SwitchingOn / Off1 Bit1.1 switchCW
97B Control ValueValue1 Byte5.10 counter pulses (0..255)CW
97B Control ValueValue2 Bytes9.1 temperature (°C)CW
97B Control ValueValue1 Byte5.1 percentage (0..100%)CW
97B Control ValueValue2 Bytes9.4 lux (Lux)CW
97B Control ValueValue2 Bytes9.21 current (mA)CW
97B Control ValueValue2 Bytes9.24 power (kW)CW
97B Control ValueValue4 Bytes14.56 power (W)CW
98B DimmingBrighter / darker4 Bit3.7 dimming controlCW
99B Dimming value 18-bit value1 Byte5.1 percentage (0..100%)CW
100B Dimming value 28-bit value1 Byte5.1 percentage (0..100%)CW
101B Dimming value 1 / timeDimming value + time3 Bytes225.1 scaling speedCW
103B Status switchingOn / Off1 Bit1.1 switchCRT
104B Status dimming value8-bit value1 Byte5.1 percentage (0..100%)CRT
105B Minimum dimming valueSet / Request value1 Byte5.1 percentage (0..100%)CRW
106B Maximum dimming valueSet / Request value1 Byte5.1 percentage (0..100%)CRW
107B Dimming time for switchingSet / Request dimming time2 Bytes7.4 time (100 ms)CRW
108B Dimming time for dimmingSet / Request dimming time2 Bytes7.4 time (100 ms)CRW
109B Dimming time for dimming value 1Set / Request dimming time2 Bytes7.4 time (100 ms)CRW
110B Dimming time for dimming value 2Set / Request dimming time2 Bytes7.4 time (100 ms)CRW
111B Logic operation 1On / Off1 Bit1.1 switchCW
112B Logic operation 2On / Off1 Bit1.1 switchCW
113B Central SwitchingOn / Off1 Bit1.1 switchCW
114B 8-bit sceneRecall / store1 Byte18.1 scene controlCW
115B Scene value/timeValue / Time3 BytesCW
116B Night modeOn / Off1 Bit1.3 enableCW
117B Night mode timerON time (seconds)2 Bytes7.5 time (s)CRW
118B Day mode timerON time 1 (seconds)2 Bytes7.5 time (s)CRW
120B Pre-warning expiration of timer periodOn / Off1 Bit1.1 switchCRT
121B Lock TimerOn / Off1 Bit1.3 enableCW
122B Override 1, User-defined ControlOn / Off1 Bit1.3 enableCW
122B Override 1, Central ControlOn / Off1 Bit1.3 enableCW
122B Override 1, LockOn / Off1 Bit1.3 enableCW
122B Override 1, Manual ONOn / Off1 Bit1.3 enableCW
122B Override 1, Permanent OFFOn / Off1 Bit1.3 enableCW
123B Override 1, Lock, ControlValue2 Bytes9.21 current (mA)CW
123B Override 1, Central Control, ControlValue2 Bytes9.21 current (mA)CW
123B Override 1, User-defined Control, Control ValueValue2 Bytes9.21 current (mA)CW
123B Override 1, Permanent OFF, Control ValueValue2 Bytes9.24 power (kW)CW
123B Override 1, Manual ON, Control ValueValue2 Bytes9.24 power (kW)CW
123B Override 1, Lock, ControlValue2 Bytes9.24 power (kW)CW
123B Override 1, Lock, ControlValue4 Bytes14.56 power (W)CW
123B Override 1, User-defined Control, Control ValueValue2 Bytes9.24 power (kW)CW
123B Override 1, Permanent OFF, Control ValueValue4 Bytes14.56 power (W)CW
123B Override 1, Manual ON, Control ValueValue4 Bytes14.56 power (W)CW
123B Override 1, Manual ON, Control ValueValue2 Bytes9.21 current (mA)CW
123B Override 1, Central Control, ControlValue4 Bytes14.56 power (W)CW
123B Override 1, User-defined Control, Control ValueValue4 Bytes14.56 power (W)CW
123B Override 1, Central Control, ControlValue2 Bytes9.24 power (kW)CW
123B Override 1, Permanent OFF, Control ValueValue2 Bytes9.21 current (mA)CW
123B Override 1, Lock, ControlValue2 Bytes9.4 lux (Lux)CW
123B Override 1, Central Control, ControlValue2 Bytes9.4 lux (Lux)CW
123B Override 1, Permanent OFF, Control ValueValue1 Byte5.10 counter pulses (0..255)CW
123B Override 1, Manual ON, Control ValueValue1 Byte5.10 counter pulses (0..255)CW
123B Override 1, Lock, ControlValue1 Byte5.10 counter pulses (0..255)CW
123B Override 1, Central Control, ControlValue1 Byte5.10 counter pulses (0..255)CW
123B Override 1, User-defined Control, Control ValueValue1 Byte5.10 counter pulses (0..255)CW
123B Override 1, Permanent OFF, Control ValueValue2 Bytes9.1 temperature (°C)CW
123B Override 1, Manual ON, Control ValueValue2 Bytes9.1 temperature (°C)CW
123B Override 1, Central Control, ControlValue2 Bytes9.1 temperature (°C)CW
123B Override 1, Lock, ControlValue2 Bytes9.1 temperature (°C)CW
123B Override 1, Permanent OFF, Control ValueValue1 Byte5.1 percentage (0..100%)CW
123B Override 1, Manual ON, Control ValueValue1 Byte5.1 percentage (0..100%)CW
123B Override 1, Lock, ControlValue1 Byte5.1 percentage (0..100%)CW
123B Override 1, Central Control, ControlValue1 Byte5.1 percentage (0..100%)CW
123B Override 1, User-defined Control, Control ValueValue1 Byte5.1 percentage (0..100%)CW
123B Override 1, Permanent OFF, Control ValueValue2 Bytes9.4 lux (Lux)CW
123B Override 1, Manual ON, Control ValueValue2 Bytes9.4 lux (Lux)CW
123B Override 1, User-defined Control, Control ValueValue2 Bytes9.1 temperature (°C)CW
123B Override 1, User-defined Control, Control ValueValue2 Bytes9.4 lux (Lux)CW
124B Override 1, Forced ControlOn / Off2 Bit2.1 switch controlCW
125B Override 1, Central Control, StatusOn / Off1 Bit1.2 booleanCRT
125B Override 1, Forced Control, StatusOn / Off1 Bit1.2 booleanCRT
125B Override 1, User-defined Control, StatusOn / Off1 Bit1.2 booleanCRT
125B Override 1, Lock, StatusOn / Off1 Bit1.2 booleanCRT
125B Override 1, Permanent-OFF, StatusOn / Off1 Bit1.2 booleanCRT
125B Override 1, Manual ON, StatusOn / Off1 Bit1.2 booleanCRT
126B Override 2, User-defined ControlOn / Off1 Bit1.3 enableCW
126B Override 2, Central ControlOn / Off1 Bit1.3 enableCW
126B Override 2, LockOn / Off1 Bit1.3 enableCW
126B Override 2, Manual ONOn / Off1 Bit1.3 enableCW
126B Override 2, Permanent OFFOn / Off1 Bit1.3 enableCW
127B Override 2, Lock, ControlValue2 Bytes9.21 current (mA)CW
127B Override 2, Central Control, ControlValue2 Bytes9.21 current (mA)CW
127B Override 2, User-defined Control, Control ValueValue2 Bytes9.21 current (mA)CW
127B Override 2, Permanent OFF, Control ValueValue2 Bytes9.24 power (kW)CW
127B Override 2, Manual ON, Control ValueValue2 Bytes9.24 power (kW)CW
127B Override 2, Lock, ControlValue2 Bytes9.24 power (kW)CW
127B Override 2, Manual ON, Control ValueValue4 Bytes14.56 power (W)CW
127B Override 2, User-defined Control, Control ValueValue2 Bytes9.24 power (kW)CW
127B Override 2, Permanent OFF, Control ValueValue4 Bytes14.56 power (W)CW
127B Override 2, Lock, ControlValue4 Bytes14.56 power (W)CW
127B Override 2, Central Control, ControlValue4 Bytes14.56 power (W)CW
127B Override 2, User-defined Control, Control ValueValue4 Bytes14.56 power (W)CW
127B Override 2, Manual ON, Control ValueValue2 Bytes9.21 current (mA)CW
127B Override 2, Central Control, ControlValue2 Bytes9.24 power (kW)CW
127B Override 2, Permanent OFF, Control ValueValue2 Bytes9.21 current (mA)CW
127B Override 2, Lock, ControlValue2 Bytes9.4 lux (Lux)CW
127B Override 2, Central Control, ControlValue2 Bytes9.4 lux (Lux)CW
127B Override 2, Permanent OFF, Control ValueValue1 Byte5.10 counter pulses (0..255)CW
127B Override 2, Manual ON, Control ValueValue1 Byte5.10 counter pulses (0..255)CW
127B Override 2, Lock, ControlValue1 Byte5.10 counter pulses (0..255)CW
127B Override 2, Central Control, ControlValue1 Byte5.10 counter pulses (0..255)CW
127B Override 2, User-defined Control, Control ValueValue1 Byte5.10 counter pulses (0..255)CW
127B Override 2, Permanent OFF, Control ValueValue2 Bytes9.1 temperature (°C)CW
127B Override 2, Manual ON, Control ValueValue2 Bytes9.1 temperature (°C)CW
127B Override 2, Lock, ControlValue2 Bytes9.1 temperature (°C)CW
127B Override 2, Central Control, ControlValue2 Bytes9.1 temperature (°C)CW
127B Override 2, User-defined Control, Control ValueValue2 Bytes9.4 lux (Lux)CW
127B Override 2, Permanent OFF, Control ValueValue1 Byte5.1 percentage (0..100%)CW
127B Override 2, Manual ON, Control ValueValue1 Byte5.1 percentage (0..100%)CW
127B Override 2, Lock, ControlValue1 Byte5.1 percentage (0..100%)CW
127B Override 2, Central Control, ControlValue1 Byte5.1 percentage (0..100%)CW
127B Override 2, User-defined Control, Control ValueValue1 Byte5.1 percentage (0..100%)CW
127B Override 2, Permanent OFF, Control ValueValue2 Bytes9.4 lux (Lux)CW
127B Override 2, Manual ON, Control ValueValue2 Bytes9.4 lux (Lux)CW
127B Override 2, User-defined Control, Control ValueValue2 Bytes9.1 temperature (°C)CW
128B Override 2, Forced ControlOn / Off2 Bit2.1 switch controlCW
129B Override 2, Forced Control, StatusOn / Off1 Bit1.2 booleanCRT
129B Override 2, User-defined Control, StatusOn / Off1 Bit1.2 booleanCRT
129B Override 2, Central Control, StatusOn / Off1 Bit1.2 booleanCRT
129B Override 2, Lock, StatusOn / Off1 Bit1.2 booleanCRT
129B Override 2, Manual ON, StatusOn / Off1 Bit1.2 booleanCRT
129B Override 2, Permanent-OFF, StatusOn / Off1 Bit1.2 booleanCRT
130B Override 3, Permanent OFFOn / Off1 Bit1.3 enableCW
130B Override 3, User-defined ControlOn / Off1 Bit1.3 enableCW
130B Override 3, Manual ONOn / Off1 Bit1.3 enableCW
130B Override 3, Central ControlOn / Off1 Bit1.3 enableCW
130B Override 3, LockOn / Off1 Bit1.3 enableCW
131B Override 3, Manual ON, Control ValueValue2 Bytes9.21 current (mA)CW
131B Override 3, Lock, ControlValue2 Bytes9.21 current (mA)CW
131B Override 3, Central Control, ControlValue2 Bytes9.21 current (mA)CW
131B Override 3, User-defined Control, Control ValueValue2 Bytes9.21 current (mA)CW
131B Override 3, Permanent OFF, Control ValueValue2 Bytes9.24 power (kW)CW
131B Override 3, Manual ON, Control ValueValue2 Bytes9.24 power (kW)CW
131B Override 3, Lock, ControlValue2 Bytes9.24 power (kW)CW
131B Override 3, User-defined Control, Control ValueValue2 Bytes9.24 power (kW)CW
131B Override 3, Permanent OFF, Control ValueValue2 Bytes9.21 current (mA)CW
131B Override 3, Manual ON, Control ValueValue4 Bytes14.56 power (W)CW
131B Override 3, Lock, ControlValue4 Bytes14.56 power (W)CW
131B Override 3, Central Control, ControlValue4 Bytes14.56 power (W)CW
131B Override 3, User-defined Control, Control ValueValue4 Bytes14.56 power (W)CW
131B Override 3, Central Control, ControlValue2 Bytes9.24 power (kW)CW
131B Override 3, Permanent OFF, Control ValueValue4 Bytes14.56 power (W)CW
131B Override 3, User-defined Control, Control ValueValue2 Bytes9.4 lux (Lux)CW
131B Override 3, Lock, ControlValue2 Bytes9.4 lux (Lux)CW
131B Override 3, Permanent OFF, Control ValueValue1 Byte5.10 counter pulses (0..255)CW
131B Override 3, Manual ON, Control ValueValue1 Byte5.10 counter pulses (0..255)CW
131B Override 3, Lock, ControlValue1 Byte5.10 counter pulses (0..255)CW
131B Override 3, Central Control, ControlValue1 Byte5.10 counter pulses (0..255)CW
131B Override 3, User-defined Control, Control ValueValue1 Byte5.10 counter pulses (0..255)CW
131B Override 3, Permanent OFF, Control ValueValue2 Bytes9.1 temperature (°C)CW
131B Override 3, Lock, ControlValue2 Bytes9.1 temperature (°C)CW
131B Override 3, Central Control, ControlValue2 Bytes9.1 temperature (°C)CW
131B Override 3, Manual ON, Control ValueValue2 Bytes9.1 temperature (°C)CW
131B Override 3, Permanent OFF, Control ValueValue1 Byte5.1 percentage (0..100%)CW
131B Override 3, Manual ON, Control ValueValue1 Byte5.1 percentage (0..100%)CW
131B Override 3, Lock, ControlValue1 Byte5.1 percentage (0..100%)CW
131B Override 3, Central Control, ControlValue1 Byte5.1 percentage (0..100%)CW
131B Override 3, User-defined Control, Control ValueValue1 Byte5.1 percentage (0..100%)CW
131B Override 3, Permanent OFF, Control ValueValue2 Bytes9.4 lux (Lux)CW
131B Override 3, Manual ON, Control ValueValue2 Bytes9.4 lux (Lux)CW
131B Override 3, User-defined Control, Control ValueValue2 Bytes9.1 temperature (°C)CW
131B Override 3, Central Control, ControlValue2 Bytes9.4 lux (Lux)CW
132B Override 3, Forced ControlOn / Off2 Bit2.1 switch controlCW
133B Override 3, Central Control, StatusOn / Off1 Bit1.2 booleanCRT
133B Override 3, Forced Control, StatusOn / Off1 Bit1.2 booleanCRT
133B Override 3, User-defined Control, StatusOn / Off1 Bit1.2 booleanCRT
133B Override 3, Lock, StatusOn / Off1 Bit1.2 booleanCRT
133B Override 3, Permanent-OFF, StatusOn / Off1 Bit1.2 booleanCRT
133B Override 3, Manual ON, StatusOn / Off1 Bit1.2 booleanCRT
134B Override 4, User-defined ControlOn / Off1 Bit1.3 enableCW
134B Override 4, Central ControlOn / Off1 Bit1.3 enableCW
134B Override 4, LockOn / Off1 Bit1.3 enableCW
134B Override 4, Manual ONOn / Off1 Bit1.3 enableCW
134B Override 4, Permanent OFFOn / Off1 Bit1.3 enableCW
135B Override 4, Central Control, ControlValue2 Bytes9.21 current (mA)CW
135B Override 4, User-defined Control, Control ValueValue2 Bytes9.21 current (mA)CW
135B Override 4, Permanent OFF, Control ValueValue2 Bytes9.24 power (kW)CW
135B Override 4, Manual ON, Control ValueValue2 Bytes9.24 power (kW)CW
135B Override 4, Lock, ControlValue2 Bytes9.24 power (kW)CW
135B Override 4, Central Control, ControlValue2 Bytes9.24 power (kW)CW
135B Override 4, Manual ON, Control ValueValue4 Bytes14.56 power (W)CW
135B Override 4, Permanent OFF, Control ValueValue4 Bytes14.56 power (W)CW
135B Override 4, Lock, ControlValue4 Bytes14.56 power (W)CW
135B Override 4, Central Control, ControlValue4 Bytes14.56 power (W)CW
135B Override 4, User-defined Control, Control ValueValue4 Bytes14.56 power (W)CW
135B Override 4, Lock, ControlValue2 Bytes9.21 current (mA)CW
135B Override 4, User-defined Control, Control ValueValue2 Bytes9.24 power (kW)CW
135B Override 4, Permanent OFF, Control ValueValue2 Bytes9.21 current (mA)CW
135B Override 4, Manual ON, Control ValueValue2 Bytes9.21 current (mA)CW
135B Override 4, Central Control, ControlValue2 Bytes9.4 lux (Lux)CW
135B Override 4, Permanent OFF, Control ValueValue1 Byte5.10 counter pulses (0..255)CW
135B Override 4, Manual ON, Control ValueValue1 Byte5.10 counter pulses (0..255)CW
135B Override 4, Lock, ControlValue1 Byte5.10 counter pulses (0..255)CW
135B Override 4, Central Control, ControlValue1 Byte5.10 counter pulses (0..255)CW
135B Override 4, User-defined Control, Control ValueValue1 Byte5.10 counter pulses (0..255)CW
135B Override 4, Permanent OFF, Control ValueValue2 Bytes9.1 temperature (°C)CW
135B Override 4, Manual ON, Control ValueValue2 Bytes9.1 temperature (°C)CW
135B Override 4, Lock, ControlValue2 Bytes9.1 temperature (°C)CW
135B Override 4, User-defined Control, Control ValueValue2 Bytes9.1 temperature (°C)CW
135B Override 4, Central Control, ControlValue2 Bytes9.1 temperature (°C)CW
135B Override 4, Manual ON, Control ValueValue1 Byte5.1 percentage (0..100%)CW
135B Override 4, Lock, ControlValue1 Byte5.1 percentage (0..100%)CW
135B Override 4, Central Control, ControlValue1 Byte5.1 percentage (0..100%)CW
135B Override 4, User-defined Control, Control ValueValue1 Byte5.1 percentage (0..100%)CW
135B Override 4, Permanent OFF, Control ValueValue2 Bytes9.4 lux (Lux)CW
135B Override 4, Manual ON, Control ValueValue2 Bytes9.4 lux (Lux)CW
135B Override 4, Lock, ControlValue2 Bytes9.4 lux (Lux)CW
135B Override 4, User-defined Control, Control ValueValue2 Bytes9.4 lux (Lux)CW
135B Override 4, Permanent OFF, Control ValueValue1 Byte5.1 percentage (0..100%)CW
136B Override 4, Forced ControlOn / Off2 Bit2.1 switch controlCW
137B Override 4, User-defined Control, StatusOn / Off1 Bit1.2 booleanCRT
137B Override 4, Forced Control, StatusOn / Off1 Bit1.2 booleanCRT
137B Override 4, Central Control, StatusOn / Off1 Bit1.2 booleanCRT
137B Override 4, Lock, StatusOn / Off1 Bit1.2 booleanCRT
137B Override 4, Manual ON, StatusOn / Off1 Bit1.2 booleanCRT
137B Override 4, Permanent-OFF, StatusOn / Off1 Bit1.2 booleanCRT
138B Override 5, User-defined ControlOn / Off1 Bit1.3 enableCW
138B Override 5, Central ControlOn / Off1 Bit1.3 enableCW
138B Override 5, LockOn / Off1 Bit1.3 enableCW
138B Override 5, Manual ONOn / Off1 Bit1.3 enableCW
138B Override 5, Permanent OFFOn / Off1 Bit1.3 enableCW
139B Override 5, Lock, ControlValue2 Bytes9.21 current (mA)CW
139B Override 5, Central Control, ControlValue2 Bytes9.21 current (mA)CW
139B Override 5, User-defined Control, Control ValueValue2 Bytes9.21 current (mA)CW
139B Override 5, Permanent OFF, Control ValueValue2 Bytes9.24 power (kW)CW
139B Override 5, Manual ON, Control ValueValue2 Bytes9.24 power (kW)CW
139B Override 5, Lock, ControlValue2 Bytes9.24 power (kW)CW
139B Override 5, Manual ON, Control ValueValue4 Bytes14.56 power (W)CW
139B Override 5, User-defined Control, Control ValueValue2 Bytes9.24 power (kW)CW
139B Override 5, Permanent OFF, Control ValueValue4 Bytes14.56 power (W)CW
139B Override 5, Manual ON, Control ValueValue2 Bytes9.21 current (mA)CW
139B Override 5, Lock, ControlValue4 Bytes14.56 power (W)CW
139B Override 5, Central Control, ControlValue4 Bytes14.56 power (W)CW
139B Override 5, User-defined Control, Control ValueValue4 Bytes14.56 power (W)CW
139B Override 5, Central Control, ControlValue2 Bytes9.24 power (kW)CW
139B Override 5, Permanent OFF, Control ValueValue2 Bytes9.21 current (mA)CW
139B Override 5, User-defined Control, Control ValueValue2 Bytes9.4 lux (Lux)CW
139B Override 5, Central Control, ControlValue2 Bytes9.4 lux (Lux)CW
139B Override 5, Permanent OFF, Control ValueValue1 Byte5.10 counter pulses (0..255)CW
139B Override 5, Manual ON, Control ValueValue1 Byte5.10 counter pulses (0..255)CW
139B Override 5, Lock, ControlValue1 Byte5.10 counter pulses (0..255)CW
139B Override 5, Central Control, ControlValue1 Byte5.10 counter pulses (0..255)CW
139B Override 5, User-defined Control, Control ValueValue1 Byte5.10 counter pulses (0..255)CW
139B Override 5, Permanent OFF, Control ValueValue2 Bytes9.1 temperature (°C)CW
139B Override 5, Manual ON, Control ValueValue2 Bytes9.1 temperature (°C)CW
139B Override 5, Central Control, ControlValue2 Bytes9.1 temperature (°C)CW
139B Override 5, Lock, ControlValue2 Bytes9.1 temperature (°C)CW
139B Override 5, Permanent OFF, Control ValueValue1 Byte5.1 percentage (0..100%)CW
139B Override 5, Manual ON, Control ValueValue1 Byte5.1 percentage (0..100%)CW
139B Override 5, Lock, ControlValue1 Byte5.1 percentage (0..100%)CW
139B Override 5, Central Control, ControlValue1 Byte5.1 percentage (0..100%)CW
139B Override 5, User-defined Control, Control ValueValue1 Byte5.1 percentage (0..100%)CW
139B Override 5, Permanent OFF, Control ValueValue2 Bytes9.4 lux (Lux)CW
139B Override 5, Manual ON, Control ValueValue2 Bytes9.4 lux (Lux)CW
139B Override 5, Lock, ControlValue2 Bytes9.4 lux (Lux)CW
139B Override 5, User-defined Control, Control ValueValue2 Bytes9.1 temperature (°C)CW
140B Override 5, Forced ControlOn / Off2 Bit2.1 switch controlCW
141B Override 5, User-defined Control, StatusOn / Off1 Bit1.2 booleanCRT
141B Override 5, Forced Control, StatusOn / Off1 Bit1.2 booleanCRT
141B Override 5, Central Control, StatusOn / Off1 Bit1.2 booleanCRT
141B Override 5, Lock, StatusOn / Off1 Bit1.2 booleanCRT
141B Override 5, Manual ON, StatusOn / Off1 Bit1.2 booleanCRT
141B Override 5, Permanent-OFF, StatusOn / Off1 Bit1.2 booleanCRT
142B Override 6, Central ControlOn / Off1 Bit1.3 enableCW
142B Override 6, LockOn / Off1 Bit1.3 enableCW
142B Override 6, Manual ONOn / Off1 Bit1.3 enableCW
142B Override 6, Permanent OFFOn / Off1 Bit1.3 enableCW
142B Override 6, User-defined ControlOn / Off1 Bit1.3 enableCW
143B Override 6, Lock, ControlValue2 Bytes9.21 current (mA)CW
143B Override 6, User-defined Control, Control ValueValue2 Bytes9.21 current (mA)CW
143B Override 6, Permanent OFF, Control ValueValue2 Bytes9.24 power (kW)CW
143B Override 6, Manual ON, Control ValueValue2 Bytes9.24 power (kW)CW
143B Override 6, Lock, ControlValue2 Bytes9.24 power (kW)CW
143B Override 6, Permanent OFF, Control ValueValue4 Bytes14.56 power (W)CW
143B Override 6, User-defined Control, Control ValueValue2 Bytes9.24 power (kW)CW
143B Override 6, Manual ON, Control ValueValue2 Bytes9.21 current (mA)CW
143B Override 6, Manual ON, Control ValueValue4 Bytes14.56 power (W)CW
143B Override 6, Lock, ControlValue4 Bytes14.56 power (W)CW
143B Override 6, Central Control, ControlValue4 Bytes14.56 power (W)CW
143B Override 6, User-defined Control, Control ValueValue4 Bytes14.56 power (W)CW
143B Override 6, Central Control, ControlValue2 Bytes9.24 power (kW)CW
143B Override 6, Permanent OFF, Control ValueValue2 Bytes9.21 current (mA)CW
143B Override 6, Central Control, ControlValue2 Bytes9.21 current (mA)CW
143B Override 6, Central Control, ControlValue2 Bytes9.4 lux (Lux)CW
143B Override 6, User-defined Control, Control ValueValue2 Bytes9.4 lux (Lux)CW
143B Override 6, Permanent OFF, Control ValueValue1 Byte5.10 counter pulses (0..255)CW
143B Override 6, Manual ON, Control ValueValue1 Byte5.10 counter pulses (0..255)CW
143B Override 6, Lock, ControlValue1 Byte5.10 counter pulses (0..255)CW
143B Override 6, Central Control, ControlValue1 Byte5.10 counter pulses (0..255)CW
143B Override 6, User-defined Control, Control ValueValue1 Byte5.10 counter pulses (0..255)CW
143B Override 6, Permanent OFF, Control ValueValue2 Bytes9.1 temperature (°C)CW
143B Override 6, Manual ON, Control ValueValue2 Bytes9.1 temperature (°C)CW
143B Override 6, Central Control, ControlValue2 Bytes9.1 temperature (°C)CW
143B Override 6, Lock, ControlValue2 Bytes9.1 temperature (°C)CW
143B Override 6, Permanent OFF, Control ValueValue1 Byte5.1 percentage (0..100%)CW
143B Override 6, Manual ON, Control ValueValue1 Byte5.1 percentage (0..100%)CW
143B Override 6, Lock, ControlValue1 Byte5.1 percentage (0..100%)CW
143B Override 6, Central Control, ControlValue1 Byte5.1 percentage (0..100%)CW
143B Override 6, User-defined Control, Control ValueValue1 Byte5.1 percentage (0..100%)CW
143B Override 6, Permanent OFF, Control ValueValue2 Bytes9.4 lux (Lux)CW
143B Override 6, Manual ON, Control ValueValue2 Bytes9.4 lux (Lux)CW
143B Override 6, Lock, ControlValue2 Bytes9.4 lux (Lux)CW
143B Override 6, User-defined Control, Control ValueValue2 Bytes9.1 temperature (°C)CW
144B Override 6, Forced ControlOn / Off2 Bit2.1 switch controlCW
145B Override 6, User-defined Control, StatusOn / Off1 Bit1.2 booleanCRT
145B Override 6, Forced Control, StatusOn / Off1 Bit1.2 booleanCRT
145B Override 6, Central Control, StatusOn / Off1 Bit1.2 booleanCRT
145B Override 6, Manual ON, StatusOn / Off1 Bit1.2 booleanCRT
145B Override 6, Permanent-OFF, StatusOn / Off1 Bit1.2 booleanCRT
145B Override 6, Lock, StatusOn / Off1 Bit1.2 booleanCRT
146B Override 7, Central ControlOn / Off1 Bit1.3 enableCW
146B Override 7, LockOn / Off1 Bit1.3 enableCW
146B Override 7, Manual ONOn / Off1 Bit1.3 enableCW
146B Override 7, Permanent OFFOn / Off1 Bit1.3 enableCW
146B Override 7, User-defined ControlOn / Off1 Bit1.3 enableCW
147B Override 7, Manual ON, Control ValueValue2 Bytes9.21 current (mA)CW
147B Override 7, Lock, ControlValue2 Bytes9.21 current (mA)CW
147B Override 7, User-defined Control, Control ValueValue2 Bytes9.21 current (mA)CW
147B Override 7, Permanent OFF, Control ValueValue2 Bytes9.24 power (kW)CW
147B Override 7, Manual ON, Control ValueValue2 Bytes9.24 power (kW)CW
147B Override 7, Lock, ControlValue2 Bytes9.24 power (kW)CW
147B Override 7, Permanent OFF, Control ValueValue4 Bytes14.56 power (W)CW
147B Override 7, User-defined Control, Control ValueValue2 Bytes9.24 power (kW)CW
147B Override 7, Manual ON, Control ValueValue4 Bytes14.56 power (W)CW
147B Override 7, Lock, ControlValue4 Bytes14.56 power (W)CW
147B Override 7, Central Control, ControlValue4 Bytes14.56 power (W)CW
147B Override 7, User-defined Control, Control ValueValue4 Bytes14.56 power (W)CW
147B Override 7, Central Control, ControlValue2 Bytes9.24 power (kW)CW
147B Override 7, Permanent OFF, Control ValueValue2 Bytes9.21 current (mA)CW
147B Override 7, Central Control, ControlValue2 Bytes9.21 current (mA)CW
147B Override 7, Central Control, ControlValue2 Bytes9.4 lux (Lux)CW
147B Override 7, User-defined Control, Control ValueValue2 Bytes9.4 lux (Lux)CW
147B Override 7, Permanent OFF, Control ValueValue1 Byte5.10 counter pulses (0..255)CW
147B Override 7, Manual ON, Control ValueValue1 Byte5.10 counter pulses (0..255)CW
147B Override 7, Lock, ControlValue1 Byte5.10 counter pulses (0..255)CW
147B Override 7, Central Control, ControlValue1 Byte5.10 counter pulses (0..255)CW
147B Override 7, User-defined Control, Control ValueValue1 Byte5.10 counter pulses (0..255)CW
147B Override 7, Permanent OFF, Control ValueValue2 Bytes9.1 temperature (°C)CW
147B Override 7, Manual ON, Control ValueValue2 Bytes9.1 temperature (°C)CW
147B Override 7, Central Control, ControlValue2 Bytes9.1 temperature (°C)CW
147B Override 7, Lock, ControlValue2 Bytes9.1 temperature (°C)CW
147B Override 7, Permanent OFF, Control ValueValue1 Byte5.1 percentage (0..100%)CW
147B Override 7, Manual ON, Control ValueValue1 Byte5.1 percentage (0..100%)CW
147B Override 7, Lock, ControlValue1 Byte5.1 percentage (0..100%)CW
147B Override 7, Central Control, ControlValue1 Byte5.1 percentage (0..100%)CW
147B Override 7, User-defined Control, Control ValueValue1 Byte5.1 percentage (0..100%)CW
147B Override 7, Permanent OFF, Control ValueValue2 Bytes9.4 lux (Lux)CW
147B Override 7, Manual ON, Control ValueValue2 Bytes9.4 lux (Lux)CW
147B Override 7, Lock, ControlValue2 Bytes9.4 lux (Lux)CW
147B Override 7, User-defined Control, Control ValueValue2 Bytes9.1 temperature (°C)CW
148B Override 7, Forced ControlOn / Off2 Bit2.1 switch controlCW
149B Override 7, User-defined Control, StatusOn / Off1 Bit1.2 booleanCRT
149B Override 7, Central Control, StatusOn / Off1 Bit1.2 booleanCRT
149B Override 7, Forced Control, StatusOn / Off1 Bit1.2 booleanCRT
149B Override 7, Manual ON, StatusOn / Off1 Bit1.2 booleanCRT
149B Override 7, Permanent-OFF, StatusOn / Off1 Bit1.2 booleanCRT
149B Override 7, Lock, StatusOn / Off1 Bit1.2 booleanCRT
150B Overrides status1 = Active1 Bit1.2 booleanCRT
151B Global dimming max. limit8-bit value1 Byte5.1 percentage (0..100%)CW
152B Direct operation lockOn / Off1 Bit1.3 enableCW
153B Status direct operationOn / Off1 Bit1.2 booleanCRT
156B Dim color temperatureWarmer / colder4 Bit3.7 dimming controlCW
157B Color temperature value16-bit value2 Bytes7.600 absolute colour temperature (K)CW
158B Dim brightness and color temperatureBrighter / darker, warmer / colder3 Bytes250.600 brightness colour temperature controlCW
159B Dimming value 1 / color temperature value / dimming timeDimming value + color temperature value + dimming time6 Bytes249.600 brightness colour temperature transitionCW
160B Dimming time for dimming the color temperatureSet / Request dimming time2 Bytes7.4 time (100 ms)CRW
161B Dimming time for color temperature valueSet / Request dimming time2 Bytes7.4 time (100 ms)CRW
162B Global color temperature max. limit16-bit value2 Bytes7.600 absolute colour temperature (K)CW
163B Minimum color temperature valueSet / Request value2 Bytes7.600 absolute colour temperature (K)CRW
164B Maximum color temperature valueSet / Request value2 Bytes7.600 absolute colour temperature (K)CRW
165B Status color temperature value16-bit value2 Bytes7.600 absolute colour temperature (K)CRT
166B Number of switching cyclesValue (in cycles)4 Bytes12.1 counter pulses (unsigned)CRT
167B Number of switching cyclesSet Value (in cycles)4 Bytes12.1 counter pulses (unsigned)CW
168B Threshold for switching cyclesSet / Request value (in cycles)4 Bytes12.1 counter pulses (unsigned)CRW
169B Exceedance of threshold for switching cyclesOn / Off1 Bit1.2 booleanCRT
170B Operating hoursValue (in hours)4 Bytes12.1 counter pulses (unsigned)CRT
171B Operating hoursValue (in seconds)4 Bytes13.100 time lag (s)CRT
172B Operating hoursSet Value4 Bytes12.1 counter pulses (unsigned)CW
173B Threshold for operating hoursSet / Request value4 Bytes12.1 counter pulses (unsigned)CRW
174B Exceedance of threshold for operating hoursOn / Off1 Bit1.2 booleanCRT
183B Status failure incorrect voltage on DALI line1 = Failure1 Bit1.2 booleanCRT
184B Status failure lights defective1 = Failure1 Bit1.2 booleanCRT
185B Status failure short circuit DALI line1 = Failure1 Bit1.2 booleanCRT
186B Status failure no ECG found1 = Failure1 Bit1.2 booleanCRT
Parameters (205)
ParameterTypeDefault
Cyclical transmission of device function (0 = in operation)listDisable
Send status of device function inverted (1 = in operation)listNo
Cyclical transmission periodtime120
Specific transmission time for status objects after bus/mains voltage recoverytime15
Transmission delay between status objectstime1
Behavior after downloadlistUse device parameter
Error message on displaylistEnable
Function channel AlistDimming
Function channel BlistDimming
Operation ModelistNormal mode
Control Value InputlistDisable
Central SwitchinglistDisable
8-bit scene controllistDisable
8-bit scenes configurable by userlistDisable
Color temperature controllistDisable
Override 1listDeactivated
EnablelistDisable
dummylistNo
Override 2listDeactivated
Override 3listDeactivated
Override 4listDeactivated
Override 5listDeactivated
Override 6listDeactivated
Override 7listDeactivated
Overrides statuslistEnable
Send status on requestlistDisable
Send status on change of statuslistEnable
Send status cyclicallytime0
Direct operationlistEnable
Direct operation lockablelistDisable
Direct operation auto resettime900
Status direct operationlistDisable
Send status on change of statuslistDisable
Status switchinglistEnable
Status dimming valuelistEnable
Value change since last sent (%)unsignedInt 0…1005
Value change since last sent (%)unsignedInt 0…25513
Block time for sending of statustime10
Minimum wait time between updatestime0
Status of color temperature valuelistDisable
Value change since last sent (K)unsignedInt 0…65535100
Status failure incorrect voltage on DALI linelistDisable
Status failure lights defectivelistDisable
Status failure short circuit DALI linelistDisable
Status failure no ECG foundlistDisable
Switching state on mains voltage failurelistNo change
Dimming value on mains voltage failure (%)unsignedInt 0…1000
Dimming value at power failure (%)unsignedInt 0…2550
Color temperature on mains voltage failurelistNo change
Color temperature value on mains voltage failure (K)unsignedInt 1000…200002700
Starting value of switching object / dimming value on mains voltage recoverylistLast status of the dimming value
Dimming value on mains voltage recovery (%)unsignedInt 0…1000
Dimming value at power recovery (%)unsignedInt 0…2550
dummylistLast value
Last valuelistdummy
Starting value color temperature after mains voltage recoverylistLast color temperature value status
dummylistAs before bus voltage failure
Color temperature value on mains voltage recovery (K)unsignedInt 1000…200002700
Counting of switching cycleslistDisable
Counting of operating hourslistDisable
Dimming curvelistLinear
Value: x1unsignedInt 0…2551
Value: y1unsignedInt 0…2551
Value: x2unsignedInt 0…255255
Value: y2unsignedInt 0…255255
Value: x3unsignedInt 0…2550
Value: y3unsignedInt 0…2550
Value: x4unsignedInt 0…2550
Value: y4unsignedInt 0…2550
Value: x5unsignedInt 0…2550
Value: y5unsignedInt 0…2550
Value: x6unsignedInt 0…2550
Value: y6unsignedInt 0…2550
Value: x7unsignedInt 0…2550
Value: y7unsignedInt 0…2550
Value: x8unsignedInt 0…2550
Value: y8unsignedInt 0…2550
Value: x9unsignedInt 0…2550
Value: y9unsignedInt 0…2550
Value: x10unsignedInt 0…2550
Value: y10unsignedInt 0…2550
Value: x11unsignedInt 0…2550
Value: y11unsignedInt 0…2550
Value: x12unsignedInt 0…2550
Value: y12unsignedInt 0…2550
Value: x13unsignedInt 0…2550
Value: y13unsignedInt 0…2550
Value: x14unsignedInt 0…2550
Value: y14unsignedInt 0…2550
Value: x15unsignedInt 0…2550
Value: y15unsignedInt 0…2550
Value: x16unsignedInt 0…2550
Value: y16unsignedInt 0…2550
Minimum dimming value (%)unsignedInt 1…1001
Minimum dimming value (%)unsignedInt 0…2553
Maximum dimming value (%)unsignedInt 1…100100
Maximum dimming valueunsignedInt 0…255255
Show min/max limitation objectslistDisable
Global dimming max. limitlistDisable
Dimming time for switchingtime0
Show dimming fade time objectslistDisable
Show dimming value/time objectlistDisable
Dimming time for dimmingtime50
Dimming time for dimming value 1time50
Dimming time for dimming value 2time50
Two dimming valueslistDisable
Switch on at valuelistStart value according to parameter
Switch on value (%)unsignedInt 0…255255
Switch on value (%)unsignedInt 1…100100
Off via dimminglistEnable
On via dimminglistEnable
Switching via dimming value 1listOn and Off possible
Switching via dimming value 2listOn and Off possible
ON delaytime0
OFF delaytime0
ON delay (central switching)time0
OFF delay (central switching)time0
Night modelistDisable
Limit ON time when switching to night mode while lights are onlistEnable
Limit ON time when switching from night mode to timer mode while lights are onlistDisable
Cancel ON time when ending night mode while lights are onlistDisable
ON time during night modetime1800
Retriggering possibleunsignedInt 0…51
Warning before switching OfflistNo
Warning periodtime30
Warning signal periodtime1
Change ON time in night mode via objectlistDisable
Blocking characteritics for timer modelistDeactivate timer
dummylistDeactivate timer
ON time 1 during day modetime900
ON time 2 during day modetime900
Dimming value during ON time 2 (%)unsignedInt 0…10050
dummyunsignedInt 0…255128
Warning signal periodtime2
Change ON 1 time during day mode via objectlistDisable
Number of flashing cycles (0 = indefinite)unsignedInt 0…100005
ON time flashingtime1
OFF time flashingtime1
Minimum color temperature value (K)unsignedInt 1000…200002700
Maximum color temperature value (K)unsignedInt 1000…200006000
Global color temperature max. limitlistDisable
Dimming time for dimming the color temperaturetime50
Dimming time for color temperature valuetime50
Switch on at valuelistColor temperature value according to parameter
Switch on value (K)unsignedInt 1000…200002700
Data typelistPercentage (%) DPT 5.001
Threshold for Off (<=)unsignedInt 0…2550
Threshold for On (>=)unsignedInt 0…2551
Threshold for Off (<=)float -671088.6…670760.90
Threshold for On (>=)float -671088.6…670760.91
Threshold for Off (<=)unsignedInt 0…1000
Threshold for On (>=)unsignedInt 0…1001
Threshold for On (>=)unsignedInt 0…2553
Threshold for Off (<=)float -3.402823e+38…3.402823e+380
Threshold for On (>=)float -3.402823e+38…3.402823e+381
Logic operation 1listNo logic operation
Invert logical inputlistNo
Invert logical outputlistNo
Initial value of logic operation after mains voltage recoverylistAs before voltage failure
Logic operation 2listNo logic operation
Link 1 with scene [1…64] (0 = disable)unsignedInt 0…640
dummyunsignedInt 0…255192
Fade timetime0
Recall / store dimming valuelistEnable
Recall / store color temperature valuelistEnable
Delete learned scenelistDisable
Predefine scenelistDisable
Predefined dimming value for scene (%)unsignedInt 0…100100
Predefined switching value for sceneunsignedInt 0…255255
Predefined color temperature for scene (K)unsignedInt 1000…200006000
Link 2 with scene [1…64] (0 = disable)unsignedInt 0…640
Link 3 with scene [1…64] (0 = disable)unsignedInt 0…640
Link 4 with scene [1…64] (0 = disable)unsignedInt 0…640
Link 5 with scene [1…64] (0 = disable)unsignedInt 0…640
Link 6 with scene [1…64] (0 = disable)unsignedInt 0…640
Link 7 with scene [1…64] (0 = disable)unsignedInt 0…640
Link 8 with scene [1…64] (0 = disable)unsignedInt 0…640
Power up value (%)listOn
Control Value Input Data TypelistPercentage (%) DPT 5.001
Invert Override ControllistNo
Monitoring timetime0
Override Durationtime0
Behavior on override activationlistNo change
Behavior color temperature value on override activationlistNo change
Color temperature value on activation (K)unsignedInt 1000…200006000
Behavior switching/dimming value on override deactivationlistUpdated value
Value at deactivation (%)unsignedInt 0…1000
Value at deactivation (%)unsignedInt 0…2550
Behavior color temperature value on override deactivationlistUpdated value
Color temperature value on deactivation (K)unsignedInt 1000…200002700
Restart timer on deactivation of overridelistEnable
Status OverridelistEnable
Start value / behavior of override input on voltage recoverylistDeactivated
Start value / behavior of override input on bus voltage recoverylistDeactivated
Behavior switching/dimming value on override activationlistNo change
Value at activation (%)unsignedInt 0…100100
Value at activation (%)unsignedInt 0…255255
Value change since last sent (cycles)unsignedInt 0…42949672951
Threshold monitoringlistDisable
Threshold for switching cyclesunsignedInt 0…42949672951000
Load ChecklistDisable
Counting of operating hours inlistHours
Value change since last sent (hours)unsignedInt 0…42949672951
Value change since last sent (seconds)unsignedInt 0…42949672953600
Threshold for operating hoursunsignedInt 0…42949672951000

Version history

ApplicationApp noFingerprintFirst seenSizeFile
07 B0 A2 Switch-/Dimm actuator 2-fold DALI 9A1701 0.1 latest$9A1732012026-11-25361 KBDownload

About this file

This is the official ETS product database for the Siemens Switch/dimming actuator N 525D11, 2x DALI Broadcast (5WG1525-1DB11), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.