KNX Database
Siemens 5WG1 527-4CB23 Switch-/Dimming Actuator JB 527C23, 1x 20A,

Switch-/Dimming Actuator JB 527C23, 1x 20A, 5WG1 527-4CB23

Siemens · Order number 5WG1 527-4CB23 · Room controller › Lighting › Switch-/Dimming Actuator, 1-fold

Switch-/Dimming Actuator 1x 20A, AC 277V or AC 347V, Dimming Ctrl 0/1...10V

Download .knxprod 07 B0 A1 Dimmer 983B01 0.1 · 95 KB

Product

ManufacturerSiemens
Product nameSwitch-/Dimming Actuator JB 527C23, 1x 20A,
Order number5WG1 527-4CB23
Hardware#SDA_1fach
MediumTwisted Pair
Bus current (mA)15
Rail mountedNo
RegistrationRegistered · 2016-12-07
Languagesen-US, de-DE
Catalog entryM-0001_H-hp.5F00305-1_HP-983B-01-6EF2_CI-5WG1.20527.2D4CB23-1
Fingerprint6EF2
SHA-256ceed1e11ee8bbc199d49e1012fe4c27534139af89b5f72174c10deed52dccc30
First seen2026-11-25
Markets59 markets

Application program: 07 B0 A1 Dimmer 983B01 0.1

Application number$983B
Version0.1
Mask versionMV-07B0 (System B)
KNX Data SecureNo
Minimum ETS version4.0
Parameters453
Group objects30
Group objects (30)
NoNameFunctionSizeDPTFlags
1A, 8-bit scenerecall / save1 Byte18.1 scene controlCW
2A, LockingOn / Off1 Bit1.3 enableCW
3A, Night modeOn / Off1 Bit1.3 enableCW
4A, SwitchingOn / Off1 Bit1.1 switchCW
5A, Dimmingbrighter / darker4 Bit3.7 dimming controlCW
6A, Dimming value8-bit value1 Byte5.1 percentage (0..100%)CW
8A, Status switchingOn / Off1 Bit1.1 switchCRT
9A, Status dimming value8-bit value1 Byte5.1 percentage (0..100%)CRT
10A, Switching cycle, counter value4-byte value4 Bytes12.1 counter pulses (unsigned)CR
11A, Switching cycle, threshold4-byte value4 Bytes12.1 counter pulses (unsigned)CRW
12A, Switching cycle, threshold overrun1 = yes / 0 = no1 Bit1.2 booleanCRT
13A, Operating hours, counter value4-byte value4 Bytes12.1 counter pulses (unsigned)CR
14A, Operating hours, threshold4-byte value4 Bytes12.1 counter pulses (unsigned)CRW
15A, Operating hours, threshold overrun1 = yes / 0 = no1 Bit1.2 booleanCRT
16A, Operating time, seconds4-byte value4 Bytes13.100 time lag (s)CR
23B, 8-bit scenerecall / save1 Byte18.1 scene controlCW
24B, LockingOn / Off1 Bit1.3 enableCW
25B, Night modeOn / Off1 Bit1.3 enableCW
26B, SwitchingOn / Off1 Bit1.1 switchCW
27B, Dimmingbrighter / darker4 Bit3.7 dimming controlCW
28B, Dimming value8-bit value1 Byte5.1 percentage (0..100%)CW
30B, Status switchingOn / Off1 Bit1.1 switchCRT
31B, Status dimming value8-bit value1 Byte5.1 percentage (0..100%)CRT
32B, Switching cycle, counter value4-byte value4 Bytes12.1 counter pulses (unsigned)CR
33B, Switching cycle, threshold4-byte value4 Bytes12.1 counter pulses (unsigned)CRW
34B, Switching cycle, threshold overrun1 = yes / 0 = no1 Bit1.2 booleanCRT
35B, Operating hours, counter value4-byte value4 Bytes12.1 counter pulses (unsigned)CR
36B, Operating hours, threshold4-byte value4 Bytes12.1 counter pulses (unsigned)CRW
37B, Operating hours, threshold overrun1 = yes / 0 = no1 Bit1.2 booleanCRT
38B, Operating time, seconds4-byte value4 Bytes13.100 time lag (s)CR
Parameters (88)
ParameterTypeDefault
Transmission blocking period for status objects after supply/bus voltage recovery [1...60 seconds]unsignedInt 1…6015
Delay status objects [0…10 in 1/10 sec]unsignedInt 0…102
8-bit scenes configurable by userlistYes
Assignment 1 to scene [1...64] (0=not used)list0
Assignment 2 to scene [1...64] (0=not used)list0
Assignment 3 to scene [1...64] (0=not used)list0
Assignment 4 to scene [1...64] (0=not used)list0
Assignment 5 to scene [1...64] (0=not used)list0
Assignment 6 to scene [1...64] (0=not used)list0
Assignment 7 to scene [1...64] (0=not used)list0
Assignment 8 to scene [1...64] (0=not used)list0
PredefinelistNo
Dimming value [0...100%]unsignedInt 0…255255
Dimming value [0...100%]unsignedInt 0…100100
MinunsignedInt 0…2550
MaxunsignedInt 0…255100
Dimming time [0...255 seconds])unsignedInt 0…6553520
Dimming time [0...255 seconds])unsignedInt 0…2552
FactorunsignedInt 0…6553510
MinunsignedInt 0…655350
MaxunsignedInt 0…655352550
Delete saved scene valuelistNo
LDAB modelistNo
8-bit scene controllistNo
Status object switchinglistNo
transmit objectlistsend on read request only
Heartbeat timeunsignedInt 0…14400
Idle Period [in seconds]unsignedInt 1…601
Status object dimminglistNo
Idle Period [in seconds]unsignedInt 0…6553530
Idle Period [in seconds]unsignedInt 1…603
MinunsignedInt 0…6553510
MaxunsignedInt 0…65535600
Status object actuatorlistsend on read request only
Status object error informationlistsend on read request only
Status object loadtypelistsend on read request only
Blocking objectlistNo
Night modelistNo
ON period during night mode [1...255 minutes]unsignedInt 0…655351800
ON period during night mode [1...255 minutes]unsignedInt 1…25530
MinunsignedInt 0…6553560
MaxunsignedInt 0…6553515300
FactorunsignedInt 0…6553560
Warning before switching Off [0...255 seconds]unsignedInt 0…25530
Counting of switching cycleslistNo
Counting of power-on hourslistNo
Behaviour on KNX power voltage failurelistno change of relay contact
Behaviour on KNX power voltage recoverylistas before voltage failure
Value on power voltage recovery [0...100%]unsignedInt 0…255255
MaxunsignedInt 0…255255
Value on power voltage recovery [0...100%]unsignedInt 0…100100
Operating modelistNormal Mode
Load adaptation: Dimmer operation according tolistAutomatic detection of load type
Compensation ripple controllistYes
Minimum dimming value [1...50%]unsignedInt 0…2553
MinunsignedInt 0…2553
MaxunsignedInt 0…255128
Minimum dimming value [1...50%]unsignedInt 1…501
Maximum dimming value [10...100%]unsignedInt 0…255255
MinunsignedInt 0…25526
Maximum dimming value [10...100%]unsignedInt 10…100100
Dimming time for switching On/Off [0...255 seconds]unsignedInt 0…655350
Dimming time for switching On/Off [0...255 seconds]unsignedInt 0…2550
Dimming time for dimming darker / brighter from 0% to 100% [1...255 seconds]unsignedInt 0…6553550
Dimming time for dimming darker / brighter from 0% to 100% [1...255 seconds]unsignedInt 1…2555
Dimming time for setting dimming value from 0% to 100% [0...255 seconds]unsignedInt 0…655350
Dimming time for setting dimming value from 0% to 100% [0...255 seconds]unsignedInt 0…2550
Starting valuelistswitch On value according to parameter
Switch On value [1...100%]unsignedInt 0…255255
Switch On value [1...100%]unsignedInt 1…100100
Switching off via dimming darkerlistYes
Switching on via dimming brighterlistYes
Switching via dimming valuelistOn if dimming value >= min. dimming value
ON delay [0…600 seconds]unsignedInt 0…655350
ON delay [0…600 seconds]unsignedInt 0…6000
MaxunsignedInt 0…6553560000
FactorunsignedInt 0…65535100
OFF-delay [0…600 seconds]unsignedInt 0…655350
OFF-delay [0…600 seconds]unsignedInt 0…6000
ON period 1 [1...255 minutes]unsignedInt 1…25515
ON period 2 [1...255 minutes]unsignedInt 1…25515
Dimming value during ON period 2 [0...100%]unsignedInt 0…255128
Dimming value during ON period 2 [0...100%]unsignedInt 0…10050
ON period Flashing [1...255 seconds]unsignedInt 1…2551
OFF period Flashing [1...255 seconds]unsignedInt 1…2551
Min. output voltage [1 … 5V]list1.0
Max. output voltage [6 … 10V]list10.0
VisibilityParameterlistNo

Version history

ApplicationApp noFingerprintFirst seenSizeFile
07 B0 A1 Dimmer 983B01 0.1 latest$983B6EF22026-11-2595 KBDownload

About this file

This is the official ETS product database for the Siemens Switch-/Dimming Actuator JB 527C23, 1x 20A, (5WG1 527-4CB23), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.

More from Siemens