KNX Database

MSA237K 99 MSA237K 99 P03

Shenzhen Merrytek Technology Co., Ltd · Order number MSA237K 99 P03 · Sensor

High-altitude PIR Sensor

Download .knxprod MSA237K 99(V1.0) 1.0 · 135 KB

Product

ManufacturerShenzhen Merrytek Technology Co., Ltd
Product nameMSA237K 99
Order numberMSA237K 99 P03
Product textMSA237K 99 IR
HardwareMSA237K 99 IR
MediumTwisted Pair
Bus current (mA)10
Rail mountedNo
RegistrationCertified · 2025-06-25
Languagesen-US, zh-CN
Catalog entryM-01E6_H-MS237K.2099.20P03-16-O0073_HP-2330-10-A436-O0073_CI-MSA237K.2099.20P03-1
FingerprintA436
SHA-256bec07accffff3d3876e526e026758bfad0952e766f0c1dd99d00733f63bb13ae
First seen2026-11-25
Markets69 markets

Application program: MSA237K 99(V1.0) 1.0

Application number$2330
Version1.0
Mask versionMV-07B0 (System B)
KNX Data SecureNo
Parameters225
Group objects59
Group objects (59)
NoNameFunctionSizeDPTFlags
1GeneralHeartbeat telegram1 Bit1.2 booleanCT
2Motion detect lock1'-Lock,'0'-Unlock1 Bit1.2 booleanCRWTU
2Motion detect lock0'-Lock,'1'-Unlock1 Bit1.2 booleanCRWTU
3Motion statusDetected is '1', else is '0'1 Bit1.2 booleanCRT
4Approaching statusApproaching is '1'1 Bit1.2 booleanCRT
4xx1 Bit1.2 booleanCRT
5Moving away statusMoving away is '1'1 Bit1.2 booleanCRT
5xx1 Bit1.2 booleanCRT
6Slave 1 statusMotion status intput1 Bit1.2 booleanCRWU
7Slave 2 statusMotion status intput1 Bit1.2 booleanCRWU
8Slave 3 statusMotion status intput1 Bit1.2 booleanCRWU
9Slave 4 statusMotion status intput1 Bit1.2 booleanCRWU
10Slave 5 statusMotion status intput1 Bit1.2 booleanCRWU
11Slave 6 statusMotion status intput1 Bit1.2 booleanCRWU
12Slave 7 statusMotion status intput1 Bit1.2 booleanCRWU
13Slave 8 statusMotion status intput1 Bit1.2 booleanCRWU
14IlluminationLux value2 Bytes9.4 lux (Lux)CRT
15Lighting control 1 inputExternal input1 Bit1.2 booleanCRWU
16Lighting control 1 lock1'-Lock,'0'-Unlock1 Bit1.2 booleanCRWTU
16Lighting control 1 lock0'-Lock,'1'-Unlock1 Bit1.2 booleanCRWTU
17Lighting control 1 object1Switching1 Bit1.1 switchCRT
17Lighting control 1 object1Dimming1 Byte5.1 percentage (0..100%)CRT
17Lighting control 1 object1Scene1 Byte17.1 scene numberCRT
18Lighting control 1 object2Switching1 Bit1.1 switchCRT
18Lighting control 1 object2Dimming1 Byte5.1 percentage (0..100%)CRT
18Lighting control 1 object2Scene1 Byte17.1 scene numberCRT
19Lighting control 1 object3Switching1 Bit1.1 switchCRT
19Lighting control 1 object3Dimming1 Byte5.1 percentage (0..100%)CRT
19Lighting control 1 object3Scene1 Byte17.1 scene numberCRT
20Lighting control 2 inputExternal input1 Bit1.2 booleanCRWU
21Lighting control 2 lock1'-Lock,'0'-Unlock1 Bit1.2 booleanCRWTU
21Lighting control 2 lock0'-Lock,'1'-Unlock1 Bit1.2 booleanCRWTU
22Lighting control 2 object1Switching1 Bit1.1 switchCRT
22Lighting control 2 object1Dimming1 Byte5.1 percentage (0..100%)CRT
22Lighting control 2 object1Scene1 Byte17.1 scene numberCRT
23Lighting control 2 object2Switching1 Bit1.1 switchCRT
23Lighting control 2 object2Dimming1 Byte5.1 percentage (0..100%)CRT
23Lighting control 2 object2Scene1 Byte17.1 scene numberCRT
24Lighting control 2 object3Switching1 Bit1.1 switchCRT
24Lighting control 2 object3Dimming1 Byte5.1 percentage (0..100%)CRT
24Lighting control 2 object3Scene1 Byte17.1 scene numberCRT
25HVAC control inputExternal temperature('C)2 Bytes9.1 temperature (°C)CRWU
26HVAC control(Temp<lower)Switching output1 Bit1.1 switchCRT
27HVAC control(Temp<lower)HVAC operation mode1 Byte20.102 HVAC modeCRT
28HVAC control(Temp<lower)HVAC control mode1 Byte20.105 HVAC control modeCRT
29HVAC control(Temp<lower)HVAC set temperature('C)2 Bytes9.1 temperature (°C)CRT
30HVAC control(Temp<lower)HVAC fanspeed1 Byte5.1 percentage (0..100%)CRT
31HVAC control(lower<Temp<upper)Switching output1 Bit1.1 switchCRT
32HVAC control(lower<Temp<upper)HVAC operation mode1 Byte20.102 HVAC modeCRT
33HVAC control(lower<Temp<upper)HVAC control mode1 Byte20.105 HVAC control modeCRT
34HVAC control(lower<Temp<upper)HVAC set temperature('C)2 Bytes9.1 temperature (°C)CRT
35HVAC control(lower<Temp<upper)HVAC fanspeed1 Byte5.1 percentage (0..100%)CRT
36HVAC control(Temp>upper)Switching output1 Bit1.1 switchCRT
37HVAC control(Temp>upper)HVAC operation mode1 Byte20.102 HVAC modeCRT
38HVAC control(Temp>upper)HVAC control mode1 Byte20.105 HVAC control modeCRT
39HVAC control(Temp>upper)HVAC set temperature('C)2 Bytes9.1 temperature (°C)CRT
40HVAC control(Temp>upper)HVAC fanspeed1 Byte5.1 percentage (0..100%)CRT
41HVAC control lock1'-Lock,'0'-Unlock1 Bit1.2 booleanCRWTU
41HVAC control lock0'-Lock,'1'-Unlock1 Bit1.2 booleanCRWTU
Parameters (70)
ParameterTypeDefault
NULLlistNo
Operation delay after recovered (1..255s)unsignedInt 1…2552
Heartbeat telegramlistDisable
Heartbeat sending interval (1..65535s)unsignedInt 1…6553560
Sensor variantlistPlease select
Motion detectorlistDisable
--> Master/Slave modelistSingle sensor
Illumination detectorlistDisable
Lighting control 1listDisable
Lighting control 2listDisable
HVAC controllistDisable
Motion detector locklistDidable
--> Set to no motion after unlocklistEnable
--> Motion detector automatic unlocklistDisable
--> Motion detector automatic unlock delay time(s)unsignedInt 5…6553530
LEDlistEnable
Motion reportlistEnable
Approaching reportlistDisable
Moving away reportlistDisable
Detection sensitivitylistHigh
Detection rangelist4m
No detected hold time(s)unsignedInt 2…720030
Single modelistDisable
Report circulally(s)unsignedInt 5…65535600
Report when changelist30lux
Compensation value(lux)signedInt -100…1000
(1) Motion status inputlistDisable
--> Motion valuelistDetected is True, else is False
(2) Approaching status inputlistDisable
--> Approaching valuelistApproaching is True, else is False
(3) Illumination status inputlistDisable
--> Lux >= Threshold lowerunsignedInt 0…2000100
--> Lux <= Threshold upperunsignedInt 0…2000300
--> Illumination valuelistIn range is True, else is False
--> Lux quiverlist5%
(4) Enable external telegram inputlistDisable
--> External telegram statuslist'1' is True, '0' is False
--> Default status after bus voltage recoverylistRecovery
Lighting control locklistDidable
--> Lighting control automatic unlocklistDisable
--> Lighting control automatic unlock delay time(s)unsignedInt 5…6553530
Object1 outputlistInvalid
--> Output value when TruelistInvalid
--> Output delay when True(s)unsignedInt 0…655350
--> Output value when FalselistInvalid
--> Output delay when False(s)unsignedInt 0…655350
Object2 outputlistInvalid
Object3 outputlistInvalid
(2) Enable external temperature inputlistDisable
--> Threshold lower temperature(0.1'C)unsignedInt 0…600100
--> Threshold upper temperature(0.1'C)unsignedInt 0…600280
Output modelistInvalid
--> Switching mode outputlistTrue is '1', False is '0'
--> HVAC operation modelistAuto
--> HVAC control modelistAuto
--> HVAC temperature(0.1'C)unsignedInt 160…320260
--> HVAC fan speedunsignedInt 0…255100
--> HVAC output delay(s)unsignedInt 0…655350
When level changed, turn off the channellistDisable
HVAC automatic off when no detectedlistDisable
--> HVAC automatic off delay time(s)unsignedInt 5…6553530
HVAC control locklistDidable
--> HVAC control automatic unlocklistDisable
--> HVAC control automatic unlock delay time(s)unsignedInt 5…6553530
xlistDisable
Detection sensitivitylist100%
xlist4m
xlistApproaching is True, else is False
(2) Illumination status inputlistDisable
(3) Enable external telegram inputlistDisable

Version history

ApplicationApp noFingerprintFirst seenSizeFile
MSA237K 99(V1.0) 1.0 latest$2330A4362026-11-25135 KBDownload

About this file

This is the official ETS product database for the Shenzhen Merrytek Technology Co., Ltd MSA237K 99 (MSA237K 99 P03), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.