ST-KX-CL200
SANTAN · Order number ST-KX-CL200 · ST-KX-CL200
Download .knxprod ST-KX-CL200 0.1 · 111 KB
Product
| Manufacturer | SANTAN |
|---|---|
| Product name | ST-KX-CL200 |
| Order number | ST-KX-CL200 |
| Hardware | ST-KX-CL200 |
| Medium | Twisted Pair |
| Bus current (mA) | 30 |
| Rail mounted | No |
| Registration | Certified · 2026-04-29 |
| Languages | en-US, zh-CN |
| Catalog entry | M-02F5_H-ST.2DKX.2DCL200-0_HP-0006-01-7D07_CI-ST.2DKX.2DCL200-1 |
| Fingerprint | 7D07 |
| SHA-256 | ed27136802d64a0f82578516da47ac7845386eac49f485e1b001ed52e9fd30b7 |
| First seen | 2026-11-25 |
| Markets | 63 markets |
Application program: ST-KX-CL200 0.1
| Application number | $0006 |
|---|---|
| Version | 0.1 |
| Mask version | MV-07B0 (System B) |
| KNX Data Secure | No |
| Minimum ETS version | 6.0 |
| Parameters | 103 |
| Group objects | 43 |
Group objects (43)
| No | Name | Function | Size | DPT | Flags |
|---|---|---|---|---|---|
| 1 | Heartbeat | Heartbeat | 1 Bit | 1.1 switch | CT |
| 2 | Switch Control | Switch Control | 1 Bit | 1.8 up/down | CW |
| 3 | Curtain Status | Curtain Status | 1 Bit | 1.8 up/down | CRT |
| 4 | Stop | Stop | 1 Bit | 1.17 trigger | CW |
| 5 | Stop Status | Stop Status | 1 Bit | 1.17 trigger | CRT |
| 6 | Percentage Control | Percentage Control | 1 Byte | 5.1 percentage (0..100%) | CW |
| 7 | Percentage Status | Percentage Status | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 8 | Set Upper Limit | Set Upper Limit | 1 Bit | 1.1 switch | CW |
| 9 | Set Lower Limit | Set Lower Limit | 1 Bit | 1.1 switch | CW |
| 10 | Fine-Tune Upper Limit | Fine-Tune Upper Limit | 1 Bit | 1.1 switch | CW |
| 11 | Fine-Tune Lower Limit | Fine-Tune Lower Limit | 1 Bit | 1.1 switch | CW |
| 12 | Reset Limit Point | Reset Limit Point | 1 Bit | 1.1 switch | CW |
| 13 | Input Scene | Input Scene | 1 Byte | 18.1 scene control | CW |
| 14 | Manual Drag Control | Manual Drag Control | 1 Bit | 1.1 switch | CW |
| 15 | Motion Direction | Motion Direction | 1 Bit | 1.1 switch | CW |
| 16 | Sensor1 | Sensor1 | 1 Bit | 1.1 switch | CW |
| 17 | Sensor1 | Sensor1 | 1 Byte | 5.1 percentage (0..100%) | CW |
| 18 | Sensor1 | Sensor1 | 2 Bytes | 9.4 lux (Lux) | CW |
| 19 | Sensor2 | Sensor2 | 1 Bit | 1.1 switch | CW |
| 20 | Sensor2 | Sensor2 | 1 Byte | 5.1 percentage (0..100%) | CW |
| 21 | Sensor2 | Sensor2 | 2 Bytes | 9.4 lux (Lux) | CW |
| 22 | Sensor3 | Sensor3 | 1 Bit | 1.1 switch | CW |
| 23 | Sensor3 | Sensor3 | 1 Byte | 5.1 percentage (0..100%) | CW |
| 24 | Sensor3 | Sensor3 | 2 Bytes | 9.4 lux (Lux) | CW |
| 25 | Sensor4 | Sensor4 | 1 Bit | 1.1 switch | CW |
| 26 | Sensor4 | Sensor4 | 1 Byte | 5.1 percentage (0..100%) | CW |
| 27 | Sensor4 | Sensor4 | 2 Bytes | 9.4 lux (Lux) | CW |
| 28 | Sensor5 | Sensor5 | 1 Bit | 1.1 switch | CW |
| 29 | Sensor5 | Sensor5 | 1 Byte | 5.1 percentage (0..100%) | CW |
| 30 | Sensor5 | Sensor5 | 2 Bytes | 9.4 lux (Lux) | CW |
| 31 | Sensor6 | Sensor6 | 1 Bit | 1.1 switch | CW |
| 32 | Sensor6 | Sensor6 | 1 Byte | 5.1 percentage (0..100%) | CW |
| 33 | Sensor6 | Sensor6 | 2 Bytes | 9.4 lux (Lux) | CW |
| 34 | Sensor7 | Sensor7 | 1 Bit | 1.1 switch | CW |
| 35 | Sensor7 | Sensor7 | 1 Byte | 5.1 percentage (0..100%) | CW |
| 36 | Sensor7 | Sensor7 | 2 Bytes | 9.4 lux (Lux) | CW |
| 37 | Sensor8 | Sensor8 | 1 Bit | 1.1 switch | CW |
| 38 | Sensor8 | Sensor8 | 1 Byte | 5.1 percentage (0..100%) | CW |
| 39 | Sensor8 | Sensor8 | 2 Bytes | 9.4 lux (Lux) | CW |
| 40 | Reverse Percentage Control | Reverse Percentage Control | 1 Byte | 5.1 percentage (0..100%) | CW |
| 41 | Reverse Percentage Status | Reverse Percentage Status | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 42 | Reverse Switch Control | Reverse Switch Control | 1 Bit | 1.8 up/down | CW |
| 43 | Reverse Switch Status | Reverse Switch Status | 1 Bit | 1.8 up/down | CRT |
Parameters (56)
| Parameter | Type | Default |
|---|---|---|
| Heartbeat Enable | list | Disable |
| Heartbeat Setup | list | Always send 1 |
| Heartbeat Interval | unsignedInt 1…36000 | 30 |
| Curtain Output | list | Disable |
| Power-On Status | list | No Action |
| Manual Drag (0: Invalid, 1: Valid) | list | Disable |
| Broadcast Status | list | No broadcast |
| Sending Interval | unsignedInt 1…36000 | 300 |
| Exceed Percentage | unsignedInt 0…15 | 5 |
| Motor Debug (0: Invalid, 1: Valid) | list | Disable |
| Running Direction (0: Forward, 1: Reverse) | list | Disable |
| Scene 1 | list | Disable |
| Scene 2 | list | Disable |
| Scene 3 | list | Disable |
| Scene 4 | list | Disable |
| Scene 5 | list | Disable |
| Scene 6 | list | Disable |
| Scene 7 | list | Disable |
| Scene 8 | list | Disable |
| Scene 1 ID | list | Disable |
| Scene 2 ID | list | Disable |
| Scene 3 ID | list | Disable |
| Scene 4 ID | list | Disable |
| Scene 5 ID | list | Disable |
| Scene 6 ID | list | Disable |
| Scene 7 ID | list | Disable |
| Scene 8 ID | list | Disable |
| Scene 1 Status | list | Disable |
| Scene 2 Status | list | Disable |
| Scene 3 Status | list | Disable |
| Scene 4 Status | list | Disable |
| Scene 5 Status | list | Disable |
| Scene 6 Status | list | Disable |
| Scene 7 Status | list | Disable |
| Scene 8 Status | list | Disable |
| Percentage 1 | unsignedInt 0…100 | 0 |
| Percentage2 | unsignedInt 0…100 | 0 |
| Percentage3 | unsignedInt 0…100 | 0 |
| Percentage4 | unsignedInt 0…100 | 0 |
| Percentage5 | unsignedInt 0…100 | 0 |
| Percentage6 | unsignedInt 0…100 | 0 |
| Percentage7 | unsignedInt 0…100 | 0 |
| Percentage8 | unsignedInt 0…100 | 0 |
| Humidity Sensor | list | Disable |
| Scene | list | Disable |
| Logic Configuration | list | Disable |
| Data Type | list | 1bit |
| Comparison Operation | list | < |
| 1-Bit Comparison Operation | list | = 0 |
| Set Value (1 byte) | unsignedInt 0…255 | 0 |
| Set Value (2 bytes) | unsignedInt 0…65535 | 0 |
| Second Condition (AND) | list | Disable |
| Percentage Control | unsignedInt 0…100 | 0 |
| Illuminance Sensor | list | Disable |
| Reporting Type | list | Disable |
| Running Speed | list | Low |
Version history
| Application | App no | Fingerprint | First seen | Size | File |
|---|---|---|---|---|---|
| ST-KX-CL200 0.1 latest | $0006 | 7D07 | 2026-11-25 | 111 KB | Download |
About this file
This is the official ETS product database for the SANTAN ST-KX-CL200 (ST-KX-CL200), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.
More from SANTAN
- ST_KX_BS138E ST_KX_BS138E
- ST-KX-BC116E ST-KX-BC116E
- ST-KX-BC116WE ST-KX-BC116WE
- ST-KX-BS138WE ST-KX-BS138WE
- ST-KX-TG100 ST-KX-TG100