KNX Database

KNX_Board 4500875479

PROLUX · Order number 4500875479 · FanCoil_KNX

FanCoil_KNX

Download .knxprod FanCoil_KNX 0.2 · 71 KB

Product

ManufacturerPROLUX
Product nameKNX_Board
Order number4500875479
Product textFanCoil_KNX
HardwareKNX_module
MediumTwisted Pair
Bus current (mA)100
Rail mountedNo
RegistrationRegistered · 2019-08-19
Languagesen-US, de-DE, it-IT, ru-RU, fr-FR, pl-PL
Catalog entryM-011B_H-73241011-1-O0119_HP-0001-02-D9EC-O0119_CI-4500875479-1
FingerprintD9EC
SHA-25685f2f348422df97644868602ab33892deaa6741393b34f81a156d9297f8ae5e3
First seen2026-11-25
MarketsAustria, Czech Republic, France, Germany, Italy, Netherlands, Poland, Russia, Spain, Switzerland, Ukraine, United Kingdom

Application program: FanCoil_KNX 0.2

Application number$0001
Version0.2
Mask versionMV-07B0 (System B)
KNX Data SecureNo
Minimum ETS version4.0
Parameters11
Group objects20
Group objects (20)
NoNameFunctionSizeDPTFlags
1ON/StandbyON/Standby1 Bit1.1 switchCRWTU
2ChangeOverChange over heating/cooling1 Bit1.100 heating/coolingCW
3Set TempSet point Temp.2 Bytes9.1 temperature (°C)CRWTU
4Act TempRoom temp.2 Bytes9.1 temperature (°C)CRWTU
5Yheating(0-100%)Control value Heating/cooling1 Byte5.1 percentage (0..100%)CRWTU
6Ycooling(0-100%)Control value cooling1 Byte5.1 percentage (0..100%)CRWTU
7Speed LimitSpeed limiter1 Byte5.1 percentage (0..100%)CRWT
8BoostBoost1 Bit1.1 switchCRWTU
9VentilationVentilation1 Byte5.1 percentage (0..100%)CRWTU
10RegulArtControl type1 Bit1.6 binary valueCRWTU
11Act RotationAct. Rotation1 Byte5.1 percentage (0..100%)CRWTU
12Alarrm bitAlarm bit1 Bit1.5 alarmCRT
13CondensateAlarm condensate/dew point1 Bit1.1 switchCRT
14Alarm TxtAlarm Text14 Bytes16.0 Character String (ASCII)CRT
15Warning TxtWarning Txt14 Bytes16.0 Character String (ASCII)CRT
16Op Mode TxtOperation mode Txt14 Bytes16.0 Character String (ASCII)CRT
17COMode TxtChange over state Text14 Bytes16.0 Character String (ASCII)CRT
18wMode TxtON/Standby stateText14 Bytes16.0 Character String (ASCII)CRT
19FCU Name TxtFanCoil Type Text14 Bytes16.0 Character String (ASCII)CRT
20Regul Art TxtControl type Text14 Bytes16.0 Character String (ASCII)CRT
Parameters (11)
ParameterTypeDefault
Use of condensate pump/monitorlistNO, without pump
Flow coolinglist10
Duration Boostlist15
Speed Limiterlist100
Flow heatinglist55
Duration Ventilationlist15
Configuration ext.ControllistOnly heating
Type of controllinglist2-controller principle (Rhigh)
Type of actorslistON/OFF
cyclic request room templist0 = No request
Polarity of ON/Standbylist0(OFF)=working;1(ON)=Standby

Version history

ApplicationApp noFingerprintFirst seenSizeFile
FanCoil_KNX 0.2 latest$0001D9EC2026-11-2571 KBDownload

About this file

This is the official ETS product database for the PROLUX KNX_Board (4500875479), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.

More from PROLUX

All PROLUX products